EMC TEST REPORT. Complied

Report No.: EMC-CE-1338 Page : 1 of 39 www.compliancegroup.com EMC TEST REPORT Test report No: EMC-CE-1338 Type of Equipment : CCTV CAMERA Model...
Author: Oswin White
32 downloads 0 Views 674KB Size
Report No.: EMC-CE-1338 Page : 1 of 39 www.compliancegroup.com

EMC TEST REPORT Test report No:

EMC-CE-1338

Type of Equipment :

CCTV CAMERA

Model Name:

HD61X

Variant Model Name:

HD73X, CNB-D2750PVR, CNB-V1760PVR

Applicant:

CNB Technology Inc.

Manufacturer #1:

CNB Technology Inc.

Manufacturer #2:

CNB Electronic (shenzhen) Co., Ltd

Test standards : EN 55022:2006, Class A EN 50130-4:1995+A1:1998+A2:2003 Testing Laboratory :

EMC Compliance Ltd.

Complied

Test result :

This product complies with the requirements of the EMC Directive 2004/108/EC. The results in this report apply only to the sample tested. This test report shall not be reproduced except in full, without the written approval of EMC compliance Laboratory. Receipt date:

2008. 05.06

Date of testing: 2008. 05.14 ~ 05.16

Tested by:

Issued date: 2008. 05.20

Approved by: PARK, YONG-JIN

CHUNG, MIN-SEOK

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 2 of 39 www.compliancegroup.com

Contents 1. Applicant information ..................................................................................................................... 3 2. Laboratory information ................................................................................................................... 4 3. Test system configuration .............................................................................................................. 5 3.1 Operation environment.............................................................................................. 5 3.2 Measurement Uncertainty ....................................................................................... 6 4. Description of E.U.T......................................................................................................................... 7 4.1 General information................................................................................................... 7 4.2 Product description ................................................................................................... 7 4.3 Auxiliary equipments ................................................................................................. 8 4.4

Test configuration..................................................................................................... 8

4.5 Operating conditions ................................................................................................. 9 5. Summary of test results................................................................................................................10 5.1 Modification to the E.U.T.......................................................................................... 10 5.2 Summary of EMI emission test results ..................................................................... 10 5.3

Summary of immunity test results ........................................................................... 10

5.4 Performance criteria................................................................................................ 11 6. Test results .....................................................................................................................................13 6.1 Radiated Emission .................................................................................................. 13 6.2 Electrostatic Discharge test result ............................................................................ 18 6.3 Radio Frequency Electromagnetic Fields ................................................................. 22 6.4 Electric Fast Transient/BURST ................................................................................ 24 6.5 Surge ..................................................................................................................... 27 6.6 Conducted Immunity ............................................................................................... 30 7. E.U.T. photographs................................................................................................................ 33

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 3 of 39 www.compliancegroup.com

1. Applicant information Applicant :

CNB Technology Inc.

Address :

#701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul,153-777, Korea

Telephone :

+82-2-2109-1498

Fax. :

+82-2-2109-1440

E-mail :

[email protected]

Contact name :

LEE KI SUNG

Manufacturer#1 :

CNB Technology Inc.

Address :

#701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul,153-777, Korea

Telephone :

+82-2-2109-1498

Fax. :

+82-2-2109-1440

E-mail :

[email protected]

Contact name :

LEE KI SUNG

Manufacturer#2 :

CNB Electronic (Shenzhen) co., Ltd

Address :

4~5/F.,4 Bldg kingwingtat technology industry Park gangtou village, buji town, long gang district Shenzhen,p.r.china

Telephone :

0755-8974 6000-100

Fax. :

0775-8974 8321

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 4 of 39 www.compliancegroup.com

2. Laboratory information Address EMC compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea Telephone Number : 82 31 336 9919 Facsimile Number

: 82 31 336 4767

CBTL Testing Laboratory FCC Filing No.: 793334 FCC CAB.: KR0040 VCCI Registration No. : C-1713, R-2710, T-258 KOLAS NO.: 231 SITE MAP

Yongin city

EMC compliance

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 5 of 39 www.compliancegroup.com

3. Test system configuration 3.1

Operation environment

OATS Immunity area

: :

Temperature

Humidity

Pressure

19 °C

40 %

-

20 °C

41 %

1000 hPa

Test site These testing items were performed following locations; Semi-anechoic chamber: Radiated Emission #4(3m) OATS

: Radiated Emission (10m)

Anechoic chamber (3m) : RS Immunity area

:, ESD, EFT/Burst, Surge, CS

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 6 of 39 www.compliancegroup.com

3.2

Measurement

Uncertainty

All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on NIS 80, 81, the measurement uncertainty level with a 95% confidence level was applied. Radiated Emission measurement

:(k=2, 95%)

30-300 MHz

; 3 m: ±3.73 [dB], 10 m: ±3.71 [dB]

300-1000 MHz

; 3 m: ±3.81 [dB], 10 m: ±3.80 [dB]

Radio Frequency Electromagnetic Fields

:(k=2, 95%)

± 1.0556 [dB]

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 7 of 39 www.compliancegroup.com

4. Description of E.U.T. 4.1

General information

- HD61X is a CCTV camera.

4.2

Product description

Type of product:

CCTV CAMERA

Model name (Basic):

HD61X

Model name (Variant):

HD73X, CNB-D2750PVR, CNB-V1760PVR

Difference:

HD73X: High Resolution CNB-D2750PVR: CNB BRAND of HD61X CNB-V1760PVR: CNB BRAND of HD73X

Serial no:

-

Trade name :

-

Testing Voltage:

DC 12V

Product rating:

DC 12V

Note :

This test was done with HD61X.

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 8 of 39 www.compliancegroup.com

4.3

Auxiliary equipments Type

Model / Part #

Serial number

Manufacturer

Monitor

CX911MW

N732H1IL900530W

SAMSUNG

DC power supply

6032A

US38322201

HP

4.4

Test configuration

DC 12V

Power supply BNC cable (* 2) (*1 )

M onitor EU T

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 9 of 39 www.compliancegroup.com

Type Signal

4.5

Description

Connection (To)

Spec.

Length(m)

Note *

Power

Power supply (DC 12V)

Non-Shield

3.0

1

BNC cable

Monitor

Shield

3.0

2

Operating conditions

The EUT was configured as normal intended use.

Test mode 1

Normal operating Display mode.

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 10 of 39 www.compliancegroup.com

5. Summary of test results 5.1

Modification to the E.U.T. None

5.2

Summary of EMI emission test results Application

Test method

Conducted emission

EN 55022 Class A

Radiated emission Harmonics current Voltage fluctuations and flickers

EN 55022 Class A EN 61000-3-2:2006 EN 61000-3-3:2005

5.3

Test result N/A Complied N/A N/A

Summary of immunity test results Items Electrostatic discharge Radiated RF immunity

Application

Test method

Test result

Enclosure

EN 610004-2:1995+A1+A2:2001

Complied

Enclosure

EN 61000-4-3:1995+A1:2002

Complied

Fast transient

DC 12V Signal

EN 61000-4-4:1995+A1+A2:2004

Complied

Surge

DC 12V Signal

EN 61000-4-5:1995+A1:2001

Complied

Conducted RF immunity

DC 12V Signal

EN 61000-4-6:1996+A1:2001

Complied

Enclosure

EN 61000-4-8:1994+A1:2001

N/A

DC 12V

EN 61000-4-11:2004

N/A

DC 12V

EN 50130-4:2003

N/A

Magnetic field immunity Voltage dip/interruption Voltage variation

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 11 of 39 www.compliancegroup.com

5.4

Performance criteria

The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3V/m. For components of CCTV systems, where the picture is allowed at 10V/m, providing. (a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3V/m, any deterioration of the picture is so minor that the system could still be used; and (c) there is no observable deterioration of the picture at 1V/m. Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130dBuV. For components of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing: (a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.): EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 12 of 39 www.compliancegroup.com

(b) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and (c) there in no observable deterioration of the picture at U +120dBuV. Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130DBuv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing: (d) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.): (e) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and (f) there in no observable deterioration of the picture at U +120dBuV. Voltage dip/interruption There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 13 of 39 www.compliancegroup.com

6. Test results 6.1

Radiated Emission

Test specification

EN 55022 Sections 6, Class A

Test mode

Display mode.

Date

2008.05.15

Power supply

DC 12V

Test facility

Semi-anechoic chamber #4, 10m OATS

Temperature (°C)

18 °C

Remarks

Complied Minimum limit margin is 1.00 dB at 85.13 MHz.

6.1.1

39 %

Limits of radiated emission measurement

Frequency [MHz] 30-230 230-1000 Above 1000MHz

6.1.2

Humidity (%)

Class A(dBuV/m)@10m

Class B(dBuV/m)@10m

40 47

30 37

Measurement procedure

A pretest was performed at 3m distance in a semi-anechoic chamber for searching correct frequency. The final test was done at a 10m open area test site with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3m to 0.4m long and were hanged at a 0.4m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 14 of 39 www.compliancegroup.com

6.1.3 Used equipments Equipment

Model no.

Serial no.

Makers

Next cal. date

Test Receiver TRILOG SUPER BROADBAND ANT Antenna Mast

ESCI

100001

R&S

08.11.16

VULB9160

3228

Schwarz beck

10.02.21

A109

N/A

DAEIL

-

Turn Table

TS25

N/A

DAEIL

-

10m OATS

-

-

EMC Compliance

-

6.1.4

Used

Sample calculation

The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: FS = MR + AF + CL + AT -AG MR = Meter Reading AF = Antenna Factor CL = Cable Loss AP = Antenna Pad AG=Amplifier Gain If MR is 30dB, AF 12dB, CL 5dB, AP 10dB, AG 35dB The result (MR) is 30 + 12 + 5 + 10 –35 = 22dBuV/m

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 15 of 39 www.compliancegroup.com

6.1.5 Photographs of test setup

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 16 of 39 www.compliancegroup.com

6.1.6

Radiated emission measurement result

*3m Semi-anechoic chamber Pre-scan Data ( #4) -Horizontal

-Vertical

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 17 of 39 www.compliancegroup.com

*10m OATS measurement data Frequency [MHz] 85.13 141.88 198.63 198.63 225.45 255.36 255.38 425.63

Reading

Pol.

[dBuV/m] 28.6 10.1 20.2 24.0 17.0 25.2 22.9 18.1

V V H V H V H H

Height

angle

[m] 2.4 1.6 1.0 1.0 4.0 2.1 3.6 2.0

141 109 344 120 327 162 296 338

Correction Factor Antenna Cable 8.30 2.10 12.77 2.57 9.46 3.07 9.46 3.07 10.24 3.17 11.36 3.45 11.36 3.45 15.59 4.52

Limits

Result

Margin

[dBuV/m] 40.0 40.0 40.0 40.0 40.0 47.0 47.0 47.0

[dBuV/m] 39.00 25.44 32.72 36.52 30.43 40.02 37.71 38.21

[dB] 1.00 14.56 7.28 3.48 9.57 6.98 9.29 8.79

* Note : Reading = Test Receiver value,

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 18 of 39 www.compliancegroup.com

6.2

Electrostatic Discharge test result

Test specification

EN61000-4-2:2001

Test level

Contact: ± 2, 4, 6 kV Air: ± 2, 4, 8 kV HCP / VCP : ± 2, 4, 6 kV

Discharge impedance

330 Ω/150㎊

Power supply

DC 12V

Date

2008.05.16

Number of discharge

10

Interval between discharges

: ≥ 1s

Temperature(°C)

20°C

Remarks

Complied - There was no change of operation status during above testing.(A1) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(C1, A2)

6.2.1

Humidity (%)

41%

Pressure (mb)

1000 mb

Measurement procedure

A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8m above the reference grounded floor. A horizontal coupling plane(HCP) was placed on the table, and Connected to the reference plane via a 470㏀ resistor located in each end (0.5mm insulating support between EUT and HCP). In both cases a vertical coupling plane(VCP) OF 0.5 X 0.5m was located 10cm from the EUT’s sides. The VCP was connected to the reference plane in the same matter as the HCP.

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 19 of 39 www.compliancegroup.com

6.2.2 Used equipments Equipment

Model No.

Serial No.

Makers

Next Cal. Date

ESD Tester

PESD 1600

H011 309

HAEFELY

08.06.26

HCP

-

-

-

-

VCP

-

-

-

-

Used

6.2.3 Photographs of test setup

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 20 of 39 www.compliancegroup.com

6.2.4

Measurement result

Electrostatic Discharge (Test Point)

Air discharge Contact discharge

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 21 of 39 www.compliancegroup.com

Contact discharge Location(EUT) C1 Screw HCP (All 4 sides) VCP (All 4 sides)

Applied level (±) ±2,4,6KV ±2,4,6KV ±2,4,6KV

Result Complied Complied Complied

Air discharge Location(EUT) A1 EUT case A2 Power port

Applied level(±) ±2,4,8KV ±2,4,8KV

Result Complied Complied

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 22 of 39 www.compliancegroup.com

6.3

Radio Frequency Electromagnetic Fields

Test specification

EN 61000-4-3:2002

Tested frequency

80MHz – 2000MHz log 1% step

Test level & Modulation

1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF))

Distance

3m from EUT to tip of antenna

Dwell time

3S

Step size

1% step

Power supply

DC 12V

Date

2008.05.14

Temperature(°C)

19°C

Remarks

Complied - There was no change of operation status during above testing.(1V) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(3V,10V)

6.3.1

Humidity (%)

40%

Pressure (mb)

1002 mb

Measurement procedure

The test was performed at 3m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8m above the floor. The EUT was tested all sides, horizontal and vertical polarization. The field uniformity was calibrated for 1V/m, 3V/m, 10V/m.

6.3.2 Used equipments Equipment

Model no.

Serial no.

Makers

Next Cal. date

Power meter Power sensor (with adapter) Power sensor (with adapter)

PM2002

302852

AR

09.05.08

PH2000

303224

AR

09.05.08

PH2000

303222

AR

09.05.08

Directional coupler

DC6180

303976

AR

09.05.08

Signal generator

E4421B

GB40052295

AGILENT

08.10.25

Used

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 23 of 39 www.compliancegroup.com

Amplifier

150W1000M2

303843

AR

09.04.11

Directional Coupler

DC7144M1

320279

AR

09.02.19

Amplifier

60S1G3M2

320444

AR

09.04.11

BiconiLog Ant.

LPDA-0803

130269

ETS

-

BiconiLog Antenna

3142B

1786

EMCO

-

Field monitor

SI-300

-

TDK

-

Controller

HD 100

-

Deisel

-

Turn table

DS 412S

-

Deisel

-

Antenna mast

MA 220

-

Deisel

-

6.3.3 Photographs of test setup

6.3.4

Measurement result Location(EUT) Front side Rear side Left side Right side

Antenna polarization

Result

Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical

Complied Complied Complied Complied Complied Complied Complied Complied

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 24 of 39 www.compliancegroup.com

6.4

Electric Fast Transient/BURST

Test specification

EN61000-4-4 : 2004

Coupling

DC 12V,Signal: Clamp

Test level

DC 12V : ± 1 kV Peak Signal : ± 1 kV Peak

Repetition frequency

5 kHz, Tr/Th = 5/50nS

Coupling time

60s

Power supply

DC 12V

Date

2008.05.16

Temperature(°C)

20°C

Remarks

Complied - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.

6.4.1

Humidity (%)

41%

Pressure (mb)

1002 mb

Measurement procedure

A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.8m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5m.

6.4.2 Used equipments Equipment

Model No.

Serial No.

Makers

Next Cal. date

Generator Capacitive Coupling Clamp

UCS 500 M6

V0545100858

EM TEST

09.01.07

-

-

EM TEST

-

Used

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 25 of 39 www.compliancegroup.com

6.4.3

Photographs of test setup

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 26 of 39 www.compliancegroup.com

6.4.4

Measurement result

DC 12V

EFT coupling point L(+) N(-) L-N

(+)

(-)

Result

+1KV +1KV +1KV

-1KV -1KV -1KV

Complied Complied Complied

(+)

(-)

Result

+1KV

-1KV

Complied

Signal

EFT coupling point BNC cable

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 27 of 39 www.compliancegroup.com

6.5

Surge

Test specification

EN 61000-4-5 :2001

Coupling

DC 12V

Test level

DC 12V: 0.5,1 KV Signal: 0.5,1 KV

Surge pulse shape

Tr/Th =1.2/50uS

Coupling Impedance

DC12V: 40Ω+0.5㎌ Signal (BNC): Direct

Angles

0°,90°,180°,270°

Number of surge & Coupling time

5T/1min

Power supply

DC 12V

Date

2008.05.16

Temperature(°C)

20°C

Remarks

Complied - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.

6.5.1

Humidity (%)

41%

Pressure (mb)

1001 mb

Measurement procedure

A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.8 m wooden table. For tabletop equipment, EUT was placed on a wooden table (0.8m) above the reference plane.

6.5.2 Used equipments Equipment

Model No.

Serial No.

Makers

Next Cal. date

Generator

UCS 500 M6

V0545100858

EM TEST

09.01.07

CDN

CNV 508

1001-10

EM TEST

-

Used

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 28 of 39 www.compliancegroup.com

6.5.3

Photographs of test setup

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 29 of 39 www.compliancegroup.com

6.5.4

Measurement result

DC 12V

Coupling point L-N

(+)

(-)

Result

+0.5,1KV

-0.5,1KV

Complied

(+)

(-)

Result

+0.5,1KV

-0.5,1KV

Complied

Signal

Coupling point BNC cable

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 30 of 39 www.compliancegroup.com

6.6

Conducted Immunity

Test specification

EN 61000-4-6:2001

Tested frequency

150 KHz – 100 MHz 1% step

Test level & Modulation

1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF))

Coupling method

DC 12V : M2 Signal : clamp

Step size

1% step

Power supply

DC 12V

Date

2008.05.14

Temperature(°C)

19°C

Remarks

Complied - There was no change of operation status during above testing.(1V) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(3V,10V)

6.6.1

Humidity (%)

40%

Pressure (mb)

1002 mb

Measurement procedure

A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1m wooden table. This test were performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 150 kHz to 100MHz.This frequency range was Modulated with 1 kHz sine wave at 80%. The signal generators provided the modulated frequency at a 1% step size. The power and all network cable, I/O cables longer than 3m in length were tested.

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 31 of 39 www.compliancegroup.com

6.6.2 Used equipments Equipment

Model no.

Serial no.

Makers

Next Cal. date

CS generator

CWS 500 C S1

V0635101750

EM TEST

08.10.15

CDN

CDN M2/M3

0906-12

EM TEST

08.10.06

Attenuator

73-6-34

MU918

MCE/WEINSCHEL

09.02.04

EM Clamp

KEMZ 801

17643

Schaffner

09.04.01

EM Clamp

KEMA 801

17899

Scahffner

-

Current probe

MD720

W1345167/M6/ 0068

Schaffner

-

6.6.3

Photographs of test setup

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Used

Report No.: EMC-CE-1338 Page : 32 of 39 www.compliancegroup.com

6.6.4 Measurement result Coupling point

Coupling method

Result

Power BNC cable

CDN (M2) Clamp

Complied Complied

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 33 of 39 www.compliancegroup.com

7. E.U.T. photographs Front View

Rear View

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 34 of 39 www.compliancegroup.com

Inside

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 35 of 39 www.compliancegroup.com

Main Board

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 36 of 39 www.compliancegroup.com

Power Board

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 37 of 39 www.compliancegroup.com

LED Board

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 38 of 39 www.compliancegroup.com

Lens

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1338 Page : 39 of 39 www.compliancegroup.com

SUB Board

EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.