Report No.: EMC-CE-1338 Page : 1 of 39 www.compliancegroup.com
EMC TEST REPORT Test report No:
EMC-CE-1338
Type of Equipment :
CCTV CAMERA
Model Name:
HD61X
Variant Model Name:
HD73X, CNB-D2750PVR, CNB-V1760PVR
Applicant:
CNB Technology Inc.
Manufacturer #1:
CNB Technology Inc.
Manufacturer #2:
CNB Electronic (shenzhen) Co., Ltd
Test standards : EN 55022:2006, Class A EN 50130-4:1995+A1:1998+A2:2003 Testing Laboratory :
EMC Compliance Ltd.
Complied
Test result :
This product complies with the requirements of the EMC Directive 2004/108/EC. The results in this report apply only to the sample tested. This test report shall not be reproduced except in full, without the written approval of EMC compliance Laboratory. Receipt date:
2008. 05.06
Date of testing: 2008. 05.14 ~ 05.16
Tested by:
Issued date: 2008. 05.20
Approved by: PARK, YONG-JIN
CHUNG, MIN-SEOK
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 2 of 39 www.compliancegroup.com
Contents 1. Applicant information ..................................................................................................................... 3 2. Laboratory information ................................................................................................................... 4 3. Test system configuration .............................................................................................................. 5 3.1 Operation environment.............................................................................................. 5 3.2 Measurement Uncertainty ....................................................................................... 6 4. Description of E.U.T......................................................................................................................... 7 4.1 General information................................................................................................... 7 4.2 Product description ................................................................................................... 7 4.3 Auxiliary equipments ................................................................................................. 8 4.4
Test configuration..................................................................................................... 8
4.5 Operating conditions ................................................................................................. 9 5. Summary of test results................................................................................................................10 5.1 Modification to the E.U.T.......................................................................................... 10 5.2 Summary of EMI emission test results ..................................................................... 10 5.3
Summary of immunity test results ........................................................................... 10
5.4 Performance criteria................................................................................................ 11 6. Test results .....................................................................................................................................13 6.1 Radiated Emission .................................................................................................. 13 6.2 Electrostatic Discharge test result ............................................................................ 18 6.3 Radio Frequency Electromagnetic Fields ................................................................. 22 6.4 Electric Fast Transient/BURST ................................................................................ 24 6.5 Surge ..................................................................................................................... 27 6.6 Conducted Immunity ............................................................................................... 30 7. E.U.T. photographs................................................................................................................ 33
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 3 of 39 www.compliancegroup.com
1. Applicant information Applicant :
CNB Technology Inc.
Address :
#701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul,153-777, Korea
Telephone :
+82-2-2109-1498
Fax. :
+82-2-2109-1440
E-mail :
[email protected]
Contact name :
LEE KI SUNG
Manufacturer#1 :
CNB Technology Inc.
Address :
#701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul,153-777, Korea
Telephone :
+82-2-2109-1498
Fax. :
+82-2-2109-1440
E-mail :
[email protected]
Contact name :
LEE KI SUNG
Manufacturer#2 :
CNB Electronic (Shenzhen) co., Ltd
Address :
4~5/F.,4 Bldg kingwingtat technology industry Park gangtou village, buji town, long gang district Shenzhen,p.r.china
Telephone :
0755-8974 6000-100
Fax. :
0775-8974 8321
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 4 of 39 www.compliancegroup.com
2. Laboratory information Address EMC compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea Telephone Number : 82 31 336 9919 Facsimile Number
: 82 31 336 4767
CBTL Testing Laboratory FCC Filing No.: 793334 FCC CAB.: KR0040 VCCI Registration No. : C-1713, R-2710, T-258 KOLAS NO.: 231 SITE MAP
Yongin city
EMC compliance
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 5 of 39 www.compliancegroup.com
3. Test system configuration 3.1
Operation environment
OATS Immunity area
: :
Temperature
Humidity
Pressure
19 °C
40 %
-
20 °C
41 %
1000 hPa
Test site These testing items were performed following locations; Semi-anechoic chamber: Radiated Emission #4(3m) OATS
: Radiated Emission (10m)
Anechoic chamber (3m) : RS Immunity area
:, ESD, EFT/Burst, Surge, CS
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 6 of 39 www.compliancegroup.com
3.2
Measurement
Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on NIS 80, 81, the measurement uncertainty level with a 95% confidence level was applied. Radiated Emission measurement
:(k=2, 95%)
30-300 MHz
; 3 m: ±3.73 [dB], 10 m: ±3.71 [dB]
300-1000 MHz
; 3 m: ±3.81 [dB], 10 m: ±3.80 [dB]
Radio Frequency Electromagnetic Fields
:(k=2, 95%)
± 1.0556 [dB]
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 7 of 39 www.compliancegroup.com
4. Description of E.U.T. 4.1
General information
- HD61X is a CCTV camera.
4.2
Product description
Type of product:
CCTV CAMERA
Model name (Basic):
HD61X
Model name (Variant):
HD73X, CNB-D2750PVR, CNB-V1760PVR
Difference:
HD73X: High Resolution CNB-D2750PVR: CNB BRAND of HD61X CNB-V1760PVR: CNB BRAND of HD73X
Serial no:
-
Trade name :
-
Testing Voltage:
DC 12V
Product rating:
DC 12V
Note :
This test was done with HD61X.
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 8 of 39 www.compliancegroup.com
4.3
Auxiliary equipments Type
Model / Part #
Serial number
Manufacturer
Monitor
CX911MW
N732H1IL900530W
SAMSUNG
DC power supply
6032A
US38322201
HP
4.4
Test configuration
DC 12V
Power supply BNC cable (* 2) (*1 )
M onitor EU T
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 9 of 39 www.compliancegroup.com
Type Signal
4.5
Description
Connection (To)
Spec.
Length(m)
Note *
Power
Power supply (DC 12V)
Non-Shield
3.0
1
BNC cable
Monitor
Shield
3.0
2
Operating conditions
The EUT was configured as normal intended use.
Test mode 1
Normal operating Display mode.
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 10 of 39 www.compliancegroup.com
5. Summary of test results 5.1
Modification to the E.U.T. None
5.2
Summary of EMI emission test results Application
Test method
Conducted emission
EN 55022 Class A
Radiated emission Harmonics current Voltage fluctuations and flickers
EN 55022 Class A EN 61000-3-2:2006 EN 61000-3-3:2005
5.3
Test result N/A Complied N/A N/A
Summary of immunity test results Items Electrostatic discharge Radiated RF immunity
Application
Test method
Test result
Enclosure
EN 610004-2:1995+A1+A2:2001
Complied
Enclosure
EN 61000-4-3:1995+A1:2002
Complied
Fast transient
DC 12V Signal
EN 61000-4-4:1995+A1+A2:2004
Complied
Surge
DC 12V Signal
EN 61000-4-5:1995+A1:2001
Complied
Conducted RF immunity
DC 12V Signal
EN 61000-4-6:1996+A1:2001
Complied
Enclosure
EN 61000-4-8:1994+A1:2001
N/A
DC 12V
EN 61000-4-11:2004
N/A
DC 12V
EN 50130-4:2003
N/A
Magnetic field immunity Voltage dip/interruption Voltage variation
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 11 of 39 www.compliancegroup.com
5.4
Performance criteria
The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3V/m. For components of CCTV systems, where the picture is allowed at 10V/m, providing. (a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3V/m, any deterioration of the picture is so minor that the system could still be used; and (c) there is no observable deterioration of the picture at 1V/m. Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130dBuV. For components of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing: (a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.): EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 12 of 39 www.compliancegroup.com
(b) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and (c) there in no observable deterioration of the picture at U +120dBuV. Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130DBuv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing: (d) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.): (e) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and (f) there in no observable deterioration of the picture at U +120dBuV. Voltage dip/interruption There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 13 of 39 www.compliancegroup.com
6. Test results 6.1
Radiated Emission
Test specification
EN 55022 Sections 6, Class A
Test mode
Display mode.
Date
2008.05.15
Power supply
DC 12V
Test facility
Semi-anechoic chamber #4, 10m OATS
Temperature (°C)
18 °C
Remarks
Complied Minimum limit margin is 1.00 dB at 85.13 MHz.
6.1.1
39 %
Limits of radiated emission measurement
Frequency [MHz] 30-230 230-1000 Above 1000MHz
6.1.2
Humidity (%)
Class A(dBuV/m)@10m
Class B(dBuV/m)@10m
40 47
30 37
Measurement procedure
A pretest was performed at 3m distance in a semi-anechoic chamber for searching correct frequency. The final test was done at a 10m open area test site with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3m to 0.4m long and were hanged at a 0.4m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 14 of 39 www.compliancegroup.com
6.1.3 Used equipments Equipment
Model no.
Serial no.
Makers
Next cal. date
Test Receiver TRILOG SUPER BROADBAND ANT Antenna Mast
ESCI
100001
R&S
08.11.16
VULB9160
3228
Schwarz beck
10.02.21
A109
N/A
DAEIL
-
Turn Table
TS25
N/A
DAEIL
-
10m OATS
-
-
EMC Compliance
-
6.1.4
Used
Sample calculation
The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: FS = MR + AF + CL + AT -AG MR = Meter Reading AF = Antenna Factor CL = Cable Loss AP = Antenna Pad AG=Amplifier Gain If MR is 30dB, AF 12dB, CL 5dB, AP 10dB, AG 35dB The result (MR) is 30 + 12 + 5 + 10 –35 = 22dBuV/m
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 15 of 39 www.compliancegroup.com
6.1.5 Photographs of test setup
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 16 of 39 www.compliancegroup.com
6.1.6
Radiated emission measurement result
*3m Semi-anechoic chamber Pre-scan Data ( #4) -Horizontal
-Vertical
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 17 of 39 www.compliancegroup.com
*10m OATS measurement data Frequency [MHz] 85.13 141.88 198.63 198.63 225.45 255.36 255.38 425.63
Reading
Pol.
[dBuV/m] 28.6 10.1 20.2 24.0 17.0 25.2 22.9 18.1
V V H V H V H H
Height
angle
[m] 2.4 1.6 1.0 1.0 4.0 2.1 3.6 2.0
141 109 344 120 327 162 296 338
Correction Factor Antenna Cable 8.30 2.10 12.77 2.57 9.46 3.07 9.46 3.07 10.24 3.17 11.36 3.45 11.36 3.45 15.59 4.52
Limits
Result
Margin
[dBuV/m] 40.0 40.0 40.0 40.0 40.0 47.0 47.0 47.0
[dBuV/m] 39.00 25.44 32.72 36.52 30.43 40.02 37.71 38.21
[dB] 1.00 14.56 7.28 3.48 9.57 6.98 9.29 8.79
* Note : Reading = Test Receiver value,
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 18 of 39 www.compliancegroup.com
6.2
Electrostatic Discharge test result
Test specification
EN61000-4-2:2001
Test level
Contact: ± 2, 4, 6 kV Air: ± 2, 4, 8 kV HCP / VCP : ± 2, 4, 6 kV
Discharge impedance
330 Ω/150㎊
Power supply
DC 12V
Date
2008.05.16
Number of discharge
10
Interval between discharges
: ≥ 1s
Temperature(°C)
20°C
Remarks
Complied - There was no change of operation status during above testing.(A1) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(C1, A2)
6.2.1
Humidity (%)
41%
Pressure (mb)
1000 mb
Measurement procedure
A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8m above the reference grounded floor. A horizontal coupling plane(HCP) was placed on the table, and Connected to the reference plane via a 470㏀ resistor located in each end (0.5mm insulating support between EUT and HCP). In both cases a vertical coupling plane(VCP) OF 0.5 X 0.5m was located 10cm from the EUT’s sides. The VCP was connected to the reference plane in the same matter as the HCP.
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 19 of 39 www.compliancegroup.com
6.2.2 Used equipments Equipment
Model No.
Serial No.
Makers
Next Cal. Date
ESD Tester
PESD 1600
H011 309
HAEFELY
08.06.26
HCP
-
-
-
-
VCP
-
-
-
-
Used
6.2.3 Photographs of test setup
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 20 of 39 www.compliancegroup.com
6.2.4
Measurement result
Electrostatic Discharge (Test Point)
Air discharge Contact discharge
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 21 of 39 www.compliancegroup.com
Contact discharge Location(EUT) C1 Screw HCP (All 4 sides) VCP (All 4 sides)
Applied level (±) ±2,4,6KV ±2,4,6KV ±2,4,6KV
Result Complied Complied Complied
Air discharge Location(EUT) A1 EUT case A2 Power port
Applied level(±) ±2,4,8KV ±2,4,8KV
Result Complied Complied
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 22 of 39 www.compliancegroup.com
6.3
Radio Frequency Electromagnetic Fields
Test specification
EN 61000-4-3:2002
Tested frequency
80MHz – 2000MHz log 1% step
Test level & Modulation
1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF))
Distance
3m from EUT to tip of antenna
Dwell time
3S
Step size
1% step
Power supply
DC 12V
Date
2008.05.14
Temperature(°C)
19°C
Remarks
Complied - There was no change of operation status during above testing.(1V) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(3V,10V)
6.3.1
Humidity (%)
40%
Pressure (mb)
1002 mb
Measurement procedure
The test was performed at 3m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8m above the floor. The EUT was tested all sides, horizontal and vertical polarization. The field uniformity was calibrated for 1V/m, 3V/m, 10V/m.
6.3.2 Used equipments Equipment
Model no.
Serial no.
Makers
Next Cal. date
Power meter Power sensor (with adapter) Power sensor (with adapter)
PM2002
302852
AR
09.05.08
PH2000
303224
AR
09.05.08
PH2000
303222
AR
09.05.08
Directional coupler
DC6180
303976
AR
09.05.08
Signal generator
E4421B
GB40052295
AGILENT
08.10.25
Used
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 23 of 39 www.compliancegroup.com
Amplifier
150W1000M2
303843
AR
09.04.11
Directional Coupler
DC7144M1
320279
AR
09.02.19
Amplifier
60S1G3M2
320444
AR
09.04.11
BiconiLog Ant.
LPDA-0803
130269
ETS
-
BiconiLog Antenna
3142B
1786
EMCO
-
Field monitor
SI-300
-
TDK
-
Controller
HD 100
-
Deisel
-
Turn table
DS 412S
-
Deisel
-
Antenna mast
MA 220
-
Deisel
-
6.3.3 Photographs of test setup
6.3.4
Measurement result Location(EUT) Front side Rear side Left side Right side
Antenna polarization
Result
Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical
Complied Complied Complied Complied Complied Complied Complied Complied
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 24 of 39 www.compliancegroup.com
6.4
Electric Fast Transient/BURST
Test specification
EN61000-4-4 : 2004
Coupling
DC 12V,Signal: Clamp
Test level
DC 12V : ± 1 kV Peak Signal : ± 1 kV Peak
Repetition frequency
5 kHz, Tr/Th = 5/50nS
Coupling time
60s
Power supply
DC 12V
Date
2008.05.16
Temperature(°C)
20°C
Remarks
Complied - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.
6.4.1
Humidity (%)
41%
Pressure (mb)
1002 mb
Measurement procedure
A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.8m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5m.
6.4.2 Used equipments Equipment
Model No.
Serial No.
Makers
Next Cal. date
Generator Capacitive Coupling Clamp
UCS 500 M6
V0545100858
EM TEST
09.01.07
-
-
EM TEST
-
Used
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 25 of 39 www.compliancegroup.com
6.4.3
Photographs of test setup
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 26 of 39 www.compliancegroup.com
6.4.4
Measurement result
DC 12V
EFT coupling point L(+) N(-) L-N
(+)
(-)
Result
+1KV +1KV +1KV
-1KV -1KV -1KV
Complied Complied Complied
(+)
(-)
Result
+1KV
-1KV
Complied
Signal
EFT coupling point BNC cable
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 27 of 39 www.compliancegroup.com
6.5
Surge
Test specification
EN 61000-4-5 :2001
Coupling
DC 12V
Test level
DC 12V: 0.5,1 KV Signal: 0.5,1 KV
Surge pulse shape
Tr/Th =1.2/50uS
Coupling Impedance
DC12V: 40Ω+0.5㎌ Signal (BNC): Direct
Angles
0°,90°,180°,270°
Number of surge & Coupling time
5T/1min
Power supply
DC 12V
Date
2008.05.16
Temperature(°C)
20°C
Remarks
Complied - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.
6.5.1
Humidity (%)
41%
Pressure (mb)
1001 mb
Measurement procedure
A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.8 m wooden table. For tabletop equipment, EUT was placed on a wooden table (0.8m) above the reference plane.
6.5.2 Used equipments Equipment
Model No.
Serial No.
Makers
Next Cal. date
Generator
UCS 500 M6
V0545100858
EM TEST
09.01.07
CDN
CNV 508
1001-10
EM TEST
-
Used
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 28 of 39 www.compliancegroup.com
6.5.3
Photographs of test setup
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 29 of 39 www.compliancegroup.com
6.5.4
Measurement result
DC 12V
Coupling point L-N
(+)
(-)
Result
+0.5,1KV
-0.5,1KV
Complied
(+)
(-)
Result
+0.5,1KV
-0.5,1KV
Complied
Signal
Coupling point BNC cable
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 30 of 39 www.compliancegroup.com
6.6
Conducted Immunity
Test specification
EN 61000-4-6:2001
Tested frequency
150 KHz – 100 MHz 1% step
Test level & Modulation
1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF))
Coupling method
DC 12V : M2 Signal : clamp
Step size
1% step
Power supply
DC 12V
Date
2008.05.14
Temperature(°C)
19°C
Remarks
Complied - There was no change of operation status during above testing.(1V) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(3V,10V)
6.6.1
Humidity (%)
40%
Pressure (mb)
1002 mb
Measurement procedure
A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1m wooden table. This test were performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 150 kHz to 100MHz.This frequency range was Modulated with 1 kHz sine wave at 80%. The signal generators provided the modulated frequency at a 1% step size. The power and all network cable, I/O cables longer than 3m in length were tested.
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 31 of 39 www.compliancegroup.com
6.6.2 Used equipments Equipment
Model no.
Serial no.
Makers
Next Cal. date
CS generator
CWS 500 C S1
V0635101750
EM TEST
08.10.15
CDN
CDN M2/M3
0906-12
EM TEST
08.10.06
Attenuator
73-6-34
MU918
MCE/WEINSCHEL
09.02.04
EM Clamp
KEMZ 801
17643
Schaffner
09.04.01
EM Clamp
KEMA 801
17899
Scahffner
-
Current probe
MD720
W1345167/M6/ 0068
Schaffner
-
6.6.3
Photographs of test setup
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Used
Report No.: EMC-CE-1338 Page : 32 of 39 www.compliancegroup.com
6.6.4 Measurement result Coupling point
Coupling method
Result
Power BNC cable
CDN (M2) Clamp
Complied Complied
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 33 of 39 www.compliancegroup.com
7. E.U.T. photographs Front View
Rear View
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 34 of 39 www.compliancegroup.com
Inside
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 35 of 39 www.compliancegroup.com
Main Board
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 36 of 39 www.compliancegroup.com
Power Board
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 37 of 39 www.compliancegroup.com
LED Board
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 38 of 39 www.compliancegroup.com
Lens
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-1338 Page : 39 of 39 www.compliancegroup.com
SUB Board
EMC Compliance Ltd. 82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea TEL: 82 31 336 9919 FAX : 82 31 336 4767 This test report shall not be reproduced except in full, Without the written approval.