Customer: Saint-Gobain Sekurit Deutschland GmbH & Co. KG Glasstraße 1 52134 Herzogenrath Germany Tel.: +49 2406 82-2856 Fax: +49 2406 82-2336
EMC test report 110423-AU02+E01
Saint-Gobain Sekurit Deutschland GmbH & Co. KG Quantum Glass - Saint Gobain - France SMPS 110VAC S 80VA U Power Supply
The test results refer exclusively to the model tested. This report must not be copied without the written authorization by the lab. Revision: 1.3
Registration number: DGA-PL-224/95-03
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email:
[email protected]
Accreditation:
Registration number: DGA-PL-224/95-03 Valid until 21.12.2014
Location of Testing: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing
The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 2 of 62
Table of contents 1. Test regulation ........................................................................................................ 4 2. Equipment under test .............................................................................................. 6 3. Test configuration and mode of operation ............................................................... 7 4. Measurement of conducted emission ...................................................................... 8 5. Measurement of radiated emission (9kHz – 30MHz) ........................................... 13 6. Measurement of radiated emission ....................................................................... 19 7. Electrostatic discharge immunity test .................................................................... 24 8. Radiated, radio-frequency, electromagnetic field immunity test ............................ 28 9. Electrical fast transient (EFT)/burst immunity test ................................................. 32 10. Surge immunity test .............................................................................................. 37 11. Immunity to conducted disturbances, induced by radio-frequency fields .............. 42 12. Voltage dips, short interruptions and voltage variations immunity tests ................ 46 13. Testing of harmonics current emission .................................................................. 51 14. Testing of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems ......................................................................................... 56 15. Measurement uncertainty ...................................................................................... 61 16. Summary ............................................................................................................... 62
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 3 of 62
1. Test regulation Emission EN 55015:2006 A1: 2007 + A2:2009
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
Includes the following tests: Measurement of the conducted disturbance at mains ports in a frequency range from 9 kHz to 30 MHz. Measurement of radiated disturbance in a frequency range from 9 kHz to 1GHz.
Emission in the frequency range of 2 kHz: EN 61000-3-2:2006 + A1:2009 + A2:2009
Harmonic current emissions (equipment input current < 16 A per phase)
EN 61000-3-3:2008
Limitation of voltage fluctuations and flicker in lowvoltage supply systems for equipment with rated current < 16 A
Deviation of Regulation and Standards: No
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 4 of 62
Susceptibility EN 61547:2009
Equipment for general lighting purposes - EMC immunity requirements
Includes Basic EMC Publications: EN 61000-4-2:2009
Testing and measurement techniques Electrostatic discharge immunity test.
EN 61000-4-3:2006 +A1: 2008 +IS1:2009
Testing and measurement techniques Radiated, radio frequency, immunity test.
EN 61000-4-4:2004
Testing and measurement techniques Electrical fast transient (EFT)/burst immunity test.
EN 61000-4-5:2006
Testing and measurement techniques Surge immunity test.
EN 61000-4-6:2009
Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields.
EN 61000-4-8:1993 + A1:2001
Testing and measurement techniques Power frequency magnetic field immunity test.
EN 61000-4-11:2004
Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests.
Not applied tests: EN 61000-4-8:1993
Testing and measurement techniques Power frequency magnetic field immunity test.
Remark:
Only for equipment containing devices susceptible to magnetic fields.
Deviation of Regulation and Standards: No
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 5 of 62
2. Equipment under test Product type:
Power Supply
Model name:
SMPS 110VAC S 80VA U
Serial number:
*00013*
Manufacturer:
Saint-Gobain Sekurit Deutschland GmbH & Co. KG
Description of the EUT:
The EUT is Power Supply for LED modules.
Photo documentation
Picture 1: EUT
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 6 of 62
3. Test configuration and mode of operation Test configuration Numbers: 1 1 1
Description: EUT: Power Supply SMPS 110VAC S 80VA U Resistor-Load E00306 Multimeter
Serial No.: *00013 n/a n/a
Mode of operation The EUT was tested in the following mode of operation:
Settings:
work under load
Applied Software:
none
Failure criterion for test of immunity from disturbances: It was observed whether the EUT is influenced in any form or program interruptions occurred. -variation of ampere -EUT switch off -EUT damaged
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 7 of 62
4. Measurement of conducted emission according to EN 55015
Location of measurement Description
Manufacturer
Inventory No.
Shielded chamber
Siemens - Matsushita
E00107
Measurement equipment Description
Manufacturer
Inventory No.
ESH 3
Rohde & Schwarz
E00007
ESCS 30
Rohde & Schwarz
E00003
ESCI
Rohde & Schwarz
E00001
ESU
Rohde & Schwarz
W00002
ESH3 Z2
Rohde & Schwarz
E00028
ESH 2-Z5
Rohde & Schwarz
E00004
ESH 2-Z5
Rohde & Schwarz
E00005
ENY 41
Rohde & Schwarz
E00041
ENY 22
Rohde & Schwarz
E00042
ISN LAN
EMV TESTHAUS GmbH
E00357
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 8 of 62
[dBµV]
Interference Voltage Test
100 O CISPR X Average
90
REGULATIONS: EN 55015 PEAK / CISPR / AV TEST EQUIPMENT: R&S ESCS30 (E00003) R&S ESH2-Z5 (E00005)
80
ORDER NO.: 110423-AU02+E01
70
EUT: Saint-Gobain Power Supply SMPS 110VAC S 80VA U *00013*
60
50
OPERATION MODE: normal operation 158 Ohm resistor 0.62 ampere Mains 230V AC /50Hz Phase
40
30
TEST FACILITY: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing
20
10
DATE: 2012-06-20
0
TEST ENGINEER: Michael Hofmann
-10
-20
0,1
0,15
1
10
30 Frequenz [MHz]
100 110423 ss l1.E10
Picture 2: Measurement report of conducted emission (phase L1)
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 9 of 62
[dBµV]
Interference Voltage Test
100 O CISPR X Average
90
REGULATIONS: EN 55015 PEAK / CISPR / AV TEST EQUIPMENT: R&S ESCS30 (E00003) R&S ESH2-Z5 (E00005)
80
ORDER NO.: 110423-AU02+E01
70
EUT: Saint-Gobain Power Supply SMPS 110VAC S 80VA U *00013*
60
50
OPERATION MODE: normal operation 158 Ohm resistor 0.62 ampere Mains 230V AC /50Hz Neutral
40
30
TEST FACILITY: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing
20
10
DATE: 2012-06-20
0
TEST ENGINEER: Michael Hofmann
-10
-20
0,1
0,15
1
10
30 Frequenz [MHz]
100 110423 ss n.E10
Picture 3: Measurement report of conducted emission (Neutral N)
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 10 of 62
Photo documentation
Picture 4: Test setup conducted emission
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 11 of 62
Test result The requirements according to EN 55015 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Comments:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 12 of 62
5. Measurement of radiated emission (9kHz – 30MHz) according to EN 55015 Procedure of radiated emission measurement: Scan with max-peak detector
Location of measurement Description
Manufacturer
Inventory No.
Anechoic chamber
EMV TESTHAUS GmbH
E00100
Measurement equipment Description
Manufacturer
Inventory No.
ESU26
Rohde & Schwarz
W00002
HXYZ9170
Schwarzbeck
E00546
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 13 of 62
Picture 5: Measurement result magnetic field emission (X- direction)
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 14 of 62
Picture 6: Measurement result magnetic field emission (Y- direction)
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 15 of 62
Picture 7: Measurement result magnetic field emission (Z- direction)
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 16 of 62
Photo documentation
Picture 8: Test setup conducted emission
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 17 of 62
Test result The requirements according to EN 55015 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Comments:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 18 of 62
6. Measurement of radiated emission according to EN 55015 Procedure of radiated emission measurement: Scan with max-peak detector in 3 m CDC Final CISPR measurement with quasi peak detector on 10m open site area.
Location of measurement Description
Manufacturer
Inventory No.
CDC
Albatross Projects
E00026
Open Area Test Site
EMV TESTHAUS GmbH
E00354
Measurement equipment Description
Manufacturer
Inventory No.
ESCS 30 (OATS)
Rohde & Schwarz
E00003
ESCI (CDC)
Rohde & Schwarz
E00001
ESU26
Rohde & Schwarz
W00002
VULB 9163 (OATS)
Schwarzbeck
E00013
VULB 9160 (CDC)
Schwarzbeck
E00011
MDS 20
Rohde & Schwarz
E00132
MDS 21
Rohde & Schwarz
E00010
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 19 of 62
[dBµV/m ]
Interference Radiation Test
60 X 0
REGULATIONS: EN 55022 Class B PEAK / CISPR
vertical horizontal
TEST EQUIPMENT: R&S ESCS30 (E00003) VULB 9163 (E00013)
50
ORDER NO.: 110423-AU01+E01 EUT: Saint-Gobain Sekurit Deutschland GmbH & Co. KG Power Supply SMPS 110VAC S 80VA U *00013*
40
OPERATION MODE: normal operation 80 Ohm resistor
30
TEST FACILITY: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing
20
DATE: 2012-05-07 10 TEST ENGINEER: Christian Kiermeier
0 30
100
1000 Frequenz [MHz]
cdc_01.E10
Picture 9: Measurement report of radiated emission
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 20 of 62
Interference Radiation Test Freq.
U_Rec
[MHz] 38,00
[dBµV/m] [dBµV/m] 22,6 30,0
Limit Corr. U_Ant. delta_U [dB] 7,0
[dBµV] 15,6
[dB] 7,4
Turntable
Antenna Pol.
Remark cdc_01.E10
0°
100 cm
V
108,00
22,9
30,0
6,5
16,4
7,1
143°
100 cm
H
109,00
18,0
30,0
12,2
5,8
12,0
354°
250 cm
H
109,90
18,5
30,0
12,1
6,4
11,6
349°
250 cm
H
110,70
17,9
30,0
12,0
6,0
12,1
354°
250 cm
H
111,60
17,1
30,0
11,8
5,2
12,9
349°
250 cm
H
112,60
12,7
30,0
11,7
1,1
17,3
292°
250 cm
H
124,00
12,0
30,0
10,3
1,6
18,1
291°
250 cm
H
125,80
12,6
30,0
10,1
2,5
17,4
129°
250 cm
H
127,60
13,0
30,0
9,9
3,1
17,0
151°
250 cm
H
129,40
11,4
30,0
9,7
1,7
18,6
315°
250 cm
H
131,10
13,4
30,0
9,6
3,8
16,6
267°
250 cm
H
143,20
23,4
30,0
8,8
14,6
6,6
263°
110 cm
V
145,90
25,0
30,0
8,9
16,1
5,0
186°
110 cm
V
146,80
25,1
30,0
8,9
16,2
4,9
234°
110 cm
V
149,00
24,8
30,0
9,0
15,8
5,2
57°
110 cm
V
149,50
23,5
30,0
9,0
14,5
6,5
89°
110 cm
V
216,80
12,2
30,0
13,2
-1,0
17,8
340°
250 cm
H
218,60
11,7
30,0
13,2
-1,6
18,3
316°
250 cm
H
220,40
12,7
30,0
13,3
-0,7
17,4
340°
250 cm
H
222,00
27,1
30,0
9,5
17,6
2,9
136°
100 cm
H
223,90
12,7
30,0
13,5
-0,8
17,3
291°
250 cm
H
225,70
12,3
30,0
13,6
-1,3
17,7
21°
250 cm
H
Fremdstörung UKW
DVBT
Picture 10: Frequency table of radiated emission
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 21 of 62
Photo documentation
Picture 11: Test setup of radiated emission
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 22 of 62
Test result The requirements according to EN 55015 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Comments:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 23 of 62
7. Electrostatic discharge immunity test according to EN 61000-4-2
Location of measurement Description
Manufacturer
Inventory No.
Shielded chamber
Siemens - Matsushita
E00107
Measurement equipment Description
Manufacturer
Inventory No.
ESD 3000
EMC Partner
E00040
NSG 435
Teseq
E00412
VCP
EMV TESTHAUS GmbH
E00047
HCP
EMV TESTHAUS GmbH
E00048
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 24 of 62
Test conditions Air discharge Test voltage:
2 kV 4 kV 8 kV 15 kV kV
Polarity:
positive negative
Discharges:
10 discharges per polarity
Discharging points:
All not metal parts.
test level 1 test level 2 test level 3 test level 4 test level x
Contact discharge Test voltage:
Polarity:
positive negative
Discharges:
10 discharges per polarity
Discharging points:
direct: indirect:
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
2 kV 4 kV 6 kV 8 kV kV
test level 1 test level 2 test level 3 test level 4 test level x
All metal parts. HCP, VCP
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 25 of 62
Photo documentation
Picture 12: Test setup ESD
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 26 of 62
Test result The requirements according to EN 61000-4-2 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Operating conditions during test: Criterion
A
During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B
During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 27 of 62
8. Radiated, radio-frequency, electromagnetic field immunity test according to EN 61000-4-3
Location of measurement Description
Manufacturer
Inventory No.
Anechoic chamber
EMV TESTHAUS GmbH
E00100
Measurement equipment Model
Description
Manufacturer
Inventory
SMT06
Signal Generator
Rohde & Schwarz E00036
BTA 0122-150W
Amplifier 9 kHz-220 MHz
Bonn
E00071
BLWA 2010-100W
Amplifier 200-1000 MHz
Bonn
E00072
AS0104-55/30
Amplifier 1 - 4GHz
Milmega
E00070
VULB 9163
Antenna 30 – 3000 MHz
Schwarzbeck
E00012
HL 023 A
Antenna 80 – 1300 MHz
Rohde & Schwarz E00027
BBHA 9120E
Antenne 1000 – 2700 MHz Schwarzbeck
E00018
COSF 3312
Power Switching Unit
Conformitas
E00037
NRVD
Power Meter
Rohde & Schwarz E00038
NRV-Z51
Power Measuring Head
Rohde & Schwarz E00075
NRV-Z51
Power Measuring Head
Rohde & Schwarz E00076
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 28 of 62
Test Conditions Frequency range:
80 MHz - 1000 MHz 1400 MHz - 2000 MHz 2000 MHz - 2700 MHz
Step size:
1 % of output frequency 4 % of output frequency
Field strength:
1 V/m 3 V/m 10 V/m V/m
Modulation:
Kind of Modulation: AM Modulation factor: 80 % Modulation frequency: 1 kHz
Dwell time:
3 seconds X seconds
Antenna polarization:
vertical horizontal
Test distance:
1m 3m
EUT position:
Observation of EUT:
Via video camera
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
test level 1 test level 2 test level 3 test level x
front side rear side left side right side top bottom
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 29 of 62
Photo documentation
Picture 13: Test setup of radiated immunity test
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 30 of 62
Test result The requirements according to EN 61000-4-3 are
Kept
Not Kept
Information about measurement uncertainty is on page 61.
Operating conditions during test: Criterion
A
During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B
During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 31 of 62
9. Electrical fast transient (EFT)/burst immunity test according to EN 61000-4-4
Location of measurement Description
Manufacturer
Inventory No.
Shielded chamber
Siemens - Matsushita
E000107
Measurement equipment Description
Manufacturer
Inventory No.
Transient 2000
EMC Partner
E00045
UCS 500 M4
EM Test
E00169
Coupling clamp
Schaffner
E00046
CDN 1000 network
EMC Partner
E00050
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 32 of 62
Test conditions Direct coupling of the test voltage to AC power supply ports / terminals Test voltage:
0.5 kV 1 kV 2 kV 4 kV
Polarity:
positive negative
Coupling sort:
symmetrical unsymmetrical
Test duration:
60 seconds (for each test voltage)
Description of cable:
Standard power cord AC of the EUT
5.0 kHz 5.0 kHz 5.0 kHz 2.5 kHz
test level 1 test level 2 test level 3 test level 4
Direct coupling of the test voltage to DC power supply ports / terminals Test voltage:
0.5 kV 1 kV 2 kV 4 kV
Polarity:
positive negative
Coupling sort:
symmetrical unsymmetrical
Test duration:
60 seconds (for each test voltage)
5.0 kHz 5.0 kHz 5.0 kHz 2.5 kHz
test level 1 test level 2 test level 3 test level 4
Description of cable:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 33 of 62
Direct coupling of the test voltage to signal-, data- and control lines Test voltage:
0.25 kV 0.5 kV 1 kV 2 kV
Polarity:
positive negative
Coupling sort:
symmetrical unsymmetrical capacitive
Test duration:
60 seconds (for each test voltage)
5.0 kHz 5.0 kHz 5.0 kHz 5.0 kHz
test level 1 test level 2 test level 3 test level 4
Description of cable:
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 34 of 62
Photo documentation
Picture 14: Test setup Burst
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 35 of 62
Test result The requirements according to EN 61000-4-4 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Operating conditions during test: Criterion
A
During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B
During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 36 of 62
10. Surge immunity test according to EN 61000-4-5
Location of measurement Description
Manufacturer
Inventory No.
Shielded chamber
Siemens - Matsushita
E00107
Measurement equipment Description
Manufacturer
Inventory No.
Transient 2000
EMC Partner
E00045
UCS 500 M4
EM Test
E00169
CDN 1000 network
EMC Partner
E00050
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 37 of 62
Test conditions Test voltage: Test impulse on phase and neutral (symmetrical)
0.5 kV 1 kV 2 kV 4 kV
test level 1 test level 2 test level 3 test level 4
Test impulse on phase, neutral and protective earth: (unsymmetrical)
0.5 kV 1 kV 2 kV 4 kV
test level 1 test level 2 test level 3 test level 4
Test impulse on signal and control cables: (symmetrical)
0.5 kV 1 kV 2 kV 4 kV
test level 1 test level 2 test level 3 test level 4
Test impulse on signal and control cables: (unsymmetrical)
0.5 kV 1 kV 2 kV 4 kV
test level 1 test level 2 test level 3 test level 4
Shield and frame/cabinet:
0.5 kV 1 kV 2 kV 4 kV
test level 1 test level 2 test level 3 test level 4
Polarity
positive
negative
Synchronizing angle Of test pulse:
0° 180°
90° 270°
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 38 of 62
Amount of test pulses: (for each test point and synchronizing angle)
5 pulses
Pulse repeat frequency:
1 pulse per minute
Triggering:
intern extern
Source impedance Of generator:
2 (2 + 10) (2 + 40)
Connecting points:
Test equipment:
Capacitive coupling network coupling-/decoupling device
Description of tested cable:
Standard power cord AC of the EUT
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
Power cord AC Power cord DC Signal- and control cables Cabinet
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 39 of 62
Photo documentation
Picture 15: Test setup Surge
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 40 of 62
Test result The requirements according to EN 61000-4-5 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Operating conditions during test: Criterion
A
During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B
During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 41 of 62
11. Immunity to conducted disturbances, induced by radio-frequency fields according to EN 61000-4-6
Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.
Measurement Equipment Description
Manufacturer
Inventory No.
SMT06
Rohde & Schwarz
E00036
BTA 0122-150W
Bonn
E00071
NRVD
Rohde & Schwarz
E00038
GAX1260/75
Dr. Hubert
E00332
50FH-010-30
JFW
E00062
Trilithic 10 dB 10W
Trilithic
E00355
F-120-9B
FCC
E00063
CDN M2
Erika Fiedler
E00065
CDN M3
Erika Fiedler
E00066
ENY 41
Rohde & Schwarz
E00042
ENY 22
Rohde & Schwarz
E00041
COSF 3312
Conformitas
E00037
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 42 of 62
Test conditions Frequency range:
150 kHz - 80 MHz 150 kHz - 230 MHz
Step size:
1 % of output frequency 4 % of output frequency
Test Voltage:
1V 3V 10 V XV
Modulation:
Kind of modulation: AM Modulation factor: 80 % Modulation frequency: 1 kHz
Dwell time:
3 seconds X seconds
Description of tested cable:
Standard power cord AC of the EUT with CDN M3
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
test level 1 test level 2 test level 3 test level
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 43 of 62
Photo documentation
Picture 16: Test setup induced RF
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 44 of 62
Test result The requirements according to EN 61000-4-6 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Operating conditions during test: Criterion
A
During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B
During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 45 of 62
12. Voltage dips, short interruptions and voltage variations immunity tests according to EN 61000-4-11
Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.
Measurement equipment Description Sycore / PAS5000 / ARS 16/3 / NT5000
Manufacturer
Inventory No.
S&S
E00058
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 46 of 62
Test conditions Voltage dips and short interruptions:
Test level
Voltage dips and short interruptions
Duration (in periods)
0 % UN
10 % UN
0,5 10
1 25
5 50
70 % UN
30 % UN
0,5 10
1 25
5 50
Phase of output voltage:
0° 180°
Interruptions per test voltage and -duration:
3 interruptions interruptions
Time between Interruptions:
10 seconds seconds
Tested power supply system:
single-phase system three-phase system
Climatic conditions:
45° 225°
90° 270°
Ambient temp.: Relative humidity.: Barometric pressure:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
135° 315°
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 47 of 62
Photo documentation
Picture 17: Test setup voltage dips
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 48 of 62
Test result The requirements according to EN 61000-4-11 are
Kept
Not kept
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 49 of 62
Operating conditions during test:
Test value:
Required criterion:
Operating condition during test
0 % during 1/2 period
min. criterion B
criterion A
70 % during 10 periods
min. criterion C
criterion A
Criterion
A
During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B
During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 50 of 62
13. Testing of harmonics current emission (equipment input current 16 A per phase) according to EN 61000-3-2
Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.
Measurement equipment Description Sycore / PAS5000 / ARS 16/3 / NT5000
Manufacturer
Inventory No.
S&S
E00058
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 51 of 62
Test conditions Power supply frequency:
50 Hz
Power supply voltage:
230 V
Tested power supply systems:
single-phase system three-phase system
Test duration:
2.50 minutes
Device class:
A
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
60 Hz
B
C
21 44 98
D
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 52 of 62
Photo documentation
Picture 18: Test setup harmonics current emission
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 53 of 62
Device: Specimen: Manufacturer: Type:
Comment3: Comment4: Date: Test date:
21.06.2012 21.06.2012
Maximum RMS current and corresponding values in timewindow 416: Voltage: Current: Power: Powerfactor:
230.74 Vrms 0.576 Arms 126.5 W 0.952
Testconditions:
EN 61000-3-2:2000+A2, f=50 Hz, Phase=L1, Range=4.00 A, Rated fundamental / pf: 0.248 A, 0.98, No Ztest selected Time window cycles=10/12 (200ms), Grouping of harmonics=on
P1=126.6 W CosPhi1: 0.961
THD=0.05 % THD=12.83 % 132.9 VA
THV=0.121 V THC=0.073 A
POHV=0.031 V POHC=0.004 A
PWHD=0.09 % PWHD=4.21 %
HARMONIC ANALYSIS: Test PASS Tobs = entire measurement; POHC: avg=0.00 A, limits=0.05 A; Rated I1/Pf exceeded, changed to 0.57 A/0.980 Entire measurement (2.5 min = 750 time windows) Ha
DC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Maximum
0.0141 0.5709 0.0067 0.0756 0.0013 0.0205 0.0010 0.0062 0.0007 0.0020 0.0007 0.0012 0.0004 0.0016 0.0005 0.0018 0.0004 0.0017 0.0003 0.0016 0.0004 0.0016 0.0003 0.0016 0.0003 0.0014 0.0003 0.0014 0.0002 0.0013 0.0003 0.0013 0.0003 0.0013 0.0002 0.0013 0.0002 0.0012 0.0002 0.0012 0.0002
Window
A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A
528 416 241 4 130 23 185 146 188 371 187 446 185 736 131 692 189 739 189 728 131 739 184 746 131 164 414 162 130 681 131 739 241 747 240 744 130 741 415 454 130
EN61000-3-2 Class C a) -.- - - -.- - - 0.0114 A 0.1678 A -.- - - 0.0571 A -.- - - 0.0400 A -.- - - 0.0285 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - -
Worst 2.5 min
Margin in MaxWin
100 to 150%
Exceeded
100 to 150%
Exceeded
-- -.-- -.-41.2 % -55.0 % -- -.-64.0 % -- -.-84.5 % -- -.-92.9 % -- -.-93.0 % -- -.-90.8 % -- -.-89.2 % -- -.-90.0 % -- -.-90.4 % -- -.-90.6 % -- -.-90.9 % -- -.-92.1 % -- -.-91.6 % -- -.-92.1 % -- -.-92.6 % -- -.-92.5 % -- -.-92.5 % -- -.-92.8 % -- -.-93.1 % -- -.-
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e.
n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e.
Average Value
-0.0129 A 0.5614 A 0.0021 A 0.0686 A 0.0007 A 0.0184 A 0.0003 A 0.0055 A 0.0004 A 0.0014 A 0.0004 A 0.0009 A 0.0002 A 0.0013 A 0.0003 A 0.0015 A 0.0003 A 0.0015 A 0.0002 A 0.0014 A 0.0003 A 0.0013 A 0.0002 A 0.0013 A 0.0002 A 0.0012 A 0.0002 A 0.0013 A 0.0002 A 0.0012 A 0.0002 A 0.0012 A 0.0002 A 0.0012 A 0.0001 A 0.0012 A 0.0002 A 0.0012 A 0.0002 A 0.0011 A 0.0001 A
Exceeded
P A S S
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
F A I L
Geprüft mi t EMC tes t s oft ware V2. 41c / PA S 5000 v on Spi tzenberger + S pies GmbH & Co. KG, Sc hmi ds tr 32-34, D-94234 Vi echt ac h, 21. 06. 2012
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 54 of 62
Test result The requirements according to EN 61000-3-2 are
Kept
Not kept
Information about measurement uncertainty is on page 61.
Comments:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 55 of 62
14. Testing of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems (equipment input current 16 A per phase) according to EN 61000-3-3
Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.
Measurement equipment Description Sycore / PAS5000 / ARS 16/3 / NT5000
Manufacturer
Inventory No.
S&S
E00058
Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 56 of 62
Test conditions Power supply frequency:
50 Hz
Tested power supply system
single-phase system three-phase system
Test duration:
10 minutes
Short timer flicker value Pst:
0.0520
Steady-state voltage change dc:
-.----- %
Maximum voltage change dmax:
0.127 %
Voltage change characteristic d(t):
0.000 %
Climatic conditions:
Ambient temp.: Relative humidity.: Barometric pressure:
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3
60 Hz
21 44 98
°C % kPa
Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01
Page 57 of 62
Company: Test report no: Device: Specimen: Manufacturer: Type:
EMV TESTHAUS GmbH
Comment1: Comment2: Comment3: Comment4: Date: Test date:
21.06.2012 20.06.2012
Testconditions: EN 61000-3-3:1995+A1+A2 / 230 V / 50 Hz / Phase L1 / Obs 1 x 10 min / Ztest (0.400+j0.250 FLICKER: Test PASS! Time
Pmax
15:49:05
0.005
Limits:
Pst
Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL
0.0520
-. --- -
0.000
0.127 - . - - -
1.000
0.650
0.500
4.000
X
3.300
Plt: 0.052000
X
Evaluated: PST, PLT, Sliding PLT, dc, dmax, d(t)
FLICKER: Source test PASS! Time
Pmax
15:49:05
0.000
Pst 0.0100
Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL -. --- -
0.000
0.090 - . - - -
X
Plt: 0.010000 Evaluated: PST