EMC test report AU02+E01

Customer: Saint-Gobain Sekurit Deutschland GmbH & Co. KG Glasstraße 1 52134 Herzogenrath Germany Tel.: +49 2406 82-2856 Fax: +49 2406 82-2336 EMC tes...
44 downloads 0 Views 2MB Size
Customer: Saint-Gobain Sekurit Deutschland GmbH & Co. KG Glasstraße 1 52134 Herzogenrath Germany Tel.: +49 2406 82-2856 Fax: +49 2406 82-2336

EMC test report 110423-AU02+E01

 Saint-Gobain Sekurit Deutschland GmbH & Co. KG Quantum Glass - Saint Gobain - France SMPS 110VAC S 80VA U Power Supply

The test results refer exclusively to the model tested. This report must not be copied without the written authorization by the lab. Revision: 1.3

Registration number: DGA-PL-224/95-03

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected]

Accreditation:

Registration number: DGA-PL-224/95-03 Valid until 21.12.2014

Location of Testing: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing

The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 2 of 62

Table of contents 1. Test regulation ........................................................................................................ 4 2. Equipment under test .............................................................................................. 6 3. Test configuration and mode of operation ............................................................... 7 4. Measurement of conducted emission ...................................................................... 8 5. Measurement of radiated emission (9kHz – 30MHz) ........................................... 13 6. Measurement of radiated emission ....................................................................... 19 7. Electrostatic discharge immunity test .................................................................... 24 8. Radiated, radio-frequency, electromagnetic field immunity test ............................ 28 9. Electrical fast transient (EFT)/burst immunity test ................................................. 32 10. Surge immunity test .............................................................................................. 37 11. Immunity to conducted disturbances, induced by radio-frequency fields .............. 42 12. Voltage dips, short interruptions and voltage variations immunity tests ................ 46 13. Testing of harmonics current emission .................................................................. 51 14. Testing of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems ......................................................................................... 56 15. Measurement uncertainty ...................................................................................... 61 16. Summary ............................................................................................................... 62

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 3 of 62

1. Test regulation Emission EN 55015:2006 A1: 2007 + A2:2009

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

Includes the following tests: Measurement of the conducted disturbance at mains ports in a frequency range from 9 kHz to 30 MHz. Measurement of radiated disturbance in a frequency range from 9 kHz to 1GHz.

Emission in the frequency range of  2 kHz: EN 61000-3-2:2006 + A1:2009 + A2:2009

Harmonic current emissions (equipment input current < 16 A per phase)

EN 61000-3-3:2008

Limitation of voltage fluctuations and flicker in lowvoltage supply systems for equipment with rated current < 16 A

Deviation of Regulation and Standards: No

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 4 of 62

Susceptibility EN 61547:2009

Equipment for general lighting purposes - EMC immunity requirements

Includes Basic EMC Publications: EN 61000-4-2:2009

Testing and measurement techniques Electrostatic discharge immunity test.

EN 61000-4-3:2006 +A1: 2008 +IS1:2009

Testing and measurement techniques Radiated, radio frequency, immunity test.

EN 61000-4-4:2004

Testing and measurement techniques Electrical fast transient (EFT)/burst immunity test.

EN 61000-4-5:2006

Testing and measurement techniques Surge immunity test.

EN 61000-4-6:2009

Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields.

EN 61000-4-8:1993 + A1:2001

Testing and measurement techniques Power frequency magnetic field immunity test.

EN 61000-4-11:2004

Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests.

Not applied tests: EN 61000-4-8:1993

Testing and measurement techniques Power frequency magnetic field immunity test.

Remark:

Only for equipment containing devices susceptible to magnetic fields.

Deviation of Regulation and Standards: No

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 5 of 62

2. Equipment under test Product type:

Power Supply

Model name:

SMPS 110VAC S 80VA U

Serial number:

*00013*

Manufacturer:

Saint-Gobain Sekurit Deutschland GmbH & Co. KG

Description of the EUT:

The EUT is Power Supply for LED modules.

Photo documentation

Picture 1: EUT

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 6 of 62

3. Test configuration and mode of operation Test configuration Numbers: 1 1 1

Description: EUT: Power Supply SMPS 110VAC S 80VA U Resistor-Load E00306 Multimeter

Serial No.: *00013 n/a n/a

Mode of operation The EUT was tested in the following mode of operation:

Settings:

work under load

Applied Software:

none

Failure criterion for test of immunity from disturbances: It was observed whether the EUT is influenced in any form or program interruptions occurred. -variation of ampere -EUT switch off -EUT damaged

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 7 of 62

4. Measurement of conducted emission according to EN 55015

Location of measurement Description

Manufacturer

Inventory No.

Shielded chamber

Siemens - Matsushita

E00107

Measurement equipment Description

Manufacturer

Inventory No.

 ESH 3

Rohde & Schwarz

E00007

 ESCS 30

Rohde & Schwarz

E00003

 ESCI

Rohde & Schwarz

E00001

 ESU

Rohde & Schwarz

W00002

 ESH3 Z2

Rohde & Schwarz

E00028

 ESH 2-Z5

Rohde & Schwarz

E00004

 ESH 2-Z5

Rohde & Schwarz

E00005

 ENY 41

Rohde & Schwarz

E00041

 ENY 22

Rohde & Schwarz

E00042

 ISN LAN

EMV TESTHAUS GmbH

E00357

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 8 of 62

[dBµV]

Interference Voltage Test

100 O CISPR X Average

90

REGULATIONS: EN 55015 PEAK / CISPR / AV TEST EQUIPMENT: R&S ESCS30 (E00003) R&S ESH2-Z5 (E00005)

80

ORDER NO.: 110423-AU02+E01

70

EUT: Saint-Gobain Power Supply SMPS 110VAC S 80VA U *00013*

60

50

OPERATION MODE: normal operation 158 Ohm resistor 0.62 ampere Mains 230V AC /50Hz Phase

40

30

TEST FACILITY: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing

20

10

DATE: 2012-06-20

0

TEST ENGINEER: Michael Hofmann

-10

-20

0,1

0,15

1

10

30 Frequenz [MHz]

100 110423 ss l1.E10

Picture 2: Measurement report of conducted emission (phase L1)

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 9 of 62

[dBµV]

Interference Voltage Test

100 O CISPR X Average

90

REGULATIONS: EN 55015 PEAK / CISPR / AV TEST EQUIPMENT: R&S ESCS30 (E00003) R&S ESH2-Z5 (E00005)

80

ORDER NO.: 110423-AU02+E01

70

EUT: Saint-Gobain Power Supply SMPS 110VAC S 80VA U *00013*

60

50

OPERATION MODE: normal operation 158 Ohm resistor 0.62 ampere Mains 230V AC /50Hz Neutral

40

30

TEST FACILITY: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing

20

10

DATE: 2012-06-20

0

TEST ENGINEER: Michael Hofmann

-10

-20

0,1

0,15

1

10

30 Frequenz [MHz]

100 110423 ss n.E10

Picture 3: Measurement report of conducted emission (Neutral N)

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 10 of 62

Photo documentation

Picture 4: Test setup conducted emission

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 11 of 62

Test result The requirements according to EN 55015 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Comments:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 12 of 62

5. Measurement of radiated emission (9kHz – 30MHz) according to EN 55015 Procedure of radiated emission measurement:  Scan with max-peak detector

Location of measurement Description

Manufacturer

Inventory No.

Anechoic chamber

EMV TESTHAUS GmbH

E00100

Measurement equipment Description

Manufacturer

Inventory No.

 ESU26

Rohde & Schwarz

W00002

 HXYZ9170

Schwarzbeck

E00546

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 13 of 62

Picture 5: Measurement result magnetic field emission (X- direction)

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 14 of 62

Picture 6: Measurement result magnetic field emission (Y- direction)

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 15 of 62

Picture 7: Measurement result magnetic field emission (Z- direction)

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 16 of 62

Photo documentation

Picture 8: Test setup conducted emission

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 17 of 62

Test result The requirements according to EN 55015 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Comments:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 18 of 62

6. Measurement of radiated emission according to EN 55015 Procedure of radiated emission measurement:  Scan with max-peak detector in 3 m CDC  Final CISPR measurement with quasi peak detector on 10m open site area.

Location of measurement Description

Manufacturer

Inventory No.

CDC

Albatross Projects

E00026

Open Area Test Site

EMV TESTHAUS GmbH

E00354

Measurement equipment Description

Manufacturer

Inventory No.

 ESCS 30 (OATS)

Rohde & Schwarz

E00003

 ESCI (CDC)

Rohde & Schwarz

E00001

 ESU26

Rohde & Schwarz

W00002

 VULB 9163 (OATS)

Schwarzbeck

E00013

 VULB 9160 (CDC)

Schwarzbeck

E00011

 MDS 20

Rohde & Schwarz

E00132

 MDS 21

Rohde & Schwarz

E00010

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 19 of 62

[dBµV/m ]

Interference Radiation Test

60 X 0

REGULATIONS: EN 55022 Class B PEAK / CISPR

vertical horizontal

TEST EQUIPMENT: R&S ESCS30 (E00003) VULB 9163 (E00013)

50

ORDER NO.: 110423-AU01+E01 EUT: Saint-Gobain Sekurit Deutschland GmbH & Co. KG Power Supply SMPS 110VAC S 80VA U *00013*

40

OPERATION MODE: normal operation 80 Ohm resistor

30

TEST FACILITY: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing

20

DATE: 2012-05-07 10 TEST ENGINEER: Christian Kiermeier

0 30

100

1000 Frequenz [MHz]

cdc_01.E10

Picture 9: Measurement report of radiated emission

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 20 of 62

Interference Radiation Test Freq.

U_Rec

[MHz] 38,00

[dBµV/m] [dBµV/m] 22,6 30,0

Limit Corr. U_Ant. delta_U [dB] 7,0

[dBµV] 15,6

[dB] 7,4

Turntable

Antenna Pol.

Remark cdc_01.E10



100 cm

V

108,00

22,9

30,0

6,5

16,4

7,1

143°

100 cm

H

109,00

18,0

30,0

12,2

5,8

12,0

354°

250 cm

H

109,90

18,5

30,0

12,1

6,4

11,6

349°

250 cm

H

110,70

17,9

30,0

12,0

6,0

12,1

354°

250 cm

H

111,60

17,1

30,0

11,8

5,2

12,9

349°

250 cm

H

112,60

12,7

30,0

11,7

1,1

17,3

292°

250 cm

H

124,00

12,0

30,0

10,3

1,6

18,1

291°

250 cm

H

125,80

12,6

30,0

10,1

2,5

17,4

129°

250 cm

H

127,60

13,0

30,0

9,9

3,1

17,0

151°

250 cm

H

129,40

11,4

30,0

9,7

1,7

18,6

315°

250 cm

H

131,10

13,4

30,0

9,6

3,8

16,6

267°

250 cm

H

143,20

23,4

30,0

8,8

14,6

6,6

263°

110 cm

V

145,90

25,0

30,0

8,9

16,1

5,0

186°

110 cm

V

146,80

25,1

30,0

8,9

16,2

4,9

234°

110 cm

V

149,00

24,8

30,0

9,0

15,8

5,2

57°

110 cm

V

149,50

23,5

30,0

9,0

14,5

6,5

89°

110 cm

V

216,80

12,2

30,0

13,2

-1,0

17,8

340°

250 cm

H

218,60

11,7

30,0

13,2

-1,6

18,3

316°

250 cm

H

220,40

12,7

30,0

13,3

-0,7

17,4

340°

250 cm

H

222,00

27,1

30,0

9,5

17,6

2,9

136°

100 cm

H

223,90

12,7

30,0

13,5

-0,8

17,3

291°

250 cm

H

225,70

12,3

30,0

13,6

-1,3

17,7

21°

250 cm

H

Fremdstörung UKW

DVBT

Picture 10: Frequency table of radiated emission

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 21 of 62

Photo documentation

Picture 11: Test setup of radiated emission

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 22 of 62

Test result The requirements according to EN 55015 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Comments:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 23 of 62

7. Electrostatic discharge immunity test according to EN 61000-4-2

Location of measurement Description

Manufacturer

Inventory No.

Shielded chamber

Siemens - Matsushita

E00107

Measurement equipment Description

Manufacturer

Inventory No.

 ESD 3000

EMC Partner

E00040

 NSG 435

Teseq

E00412

 VCP

EMV TESTHAUS GmbH

E00047

 HCP

EMV TESTHAUS GmbH

E00048

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 24 of 62

Test conditions Air discharge Test voltage:

 2 kV  4 kV  8 kV  15 kV  kV

Polarity:

 positive  negative

Discharges:

 10 discharges per polarity

Discharging points:

All not metal parts.

test level 1 test level 2 test level 3 test level 4 test level x

Contact discharge Test voltage:

    

Polarity:

 positive  negative

Discharges:

 10 discharges per polarity

Discharging points:

direct: indirect:

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

2 kV 4 kV 6 kV 8 kV kV

test level 1 test level 2 test level 3 test level 4 test level x

All metal parts. HCP, VCP

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 25 of 62

Photo documentation

Picture 12: Test setup ESD

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 26 of 62

Test result The requirements according to EN 61000-4-2 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Operating conditions during test: Criterion

 A

During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

 B

During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

 C

During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.

Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 27 of 62

8. Radiated, radio-frequency, electromagnetic field immunity test according to EN 61000-4-3

Location of measurement Description

Manufacturer

Inventory No.

Anechoic chamber

EMV TESTHAUS GmbH

E00100

Measurement equipment Model

Description

Manufacturer

Inventory

 SMT06

Signal Generator

Rohde & Schwarz E00036

 BTA 0122-150W

Amplifier 9 kHz-220 MHz

Bonn

E00071

 BLWA 2010-100W

Amplifier 200-1000 MHz

Bonn

E00072

 AS0104-55/30

Amplifier 1 - 4GHz

Milmega

E00070

 VULB 9163

Antenna 30 – 3000 MHz

Schwarzbeck

E00012

 HL 023 A

Antenna 80 – 1300 MHz

Rohde & Schwarz E00027

 BBHA 9120E

Antenne 1000 – 2700 MHz Schwarzbeck

E00018

 COSF 3312

Power Switching Unit

Conformitas

E00037

 NRVD

Power Meter

Rohde & Schwarz E00038

 NRV-Z51

Power Measuring Head

Rohde & Schwarz E00075

 NRV-Z51

Power Measuring Head

Rohde & Schwarz E00076

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 28 of 62

Test Conditions Frequency range:

 80 MHz - 1000 MHz  1400 MHz - 2000 MHz  2000 MHz - 2700 MHz

Step size:

 1 % of output frequency  4 % of output frequency

Field strength:

 1 V/m  3 V/m  10 V/m  V/m

Modulation:

Kind of Modulation: AM Modulation factor: 80 % Modulation frequency: 1 kHz

Dwell time:

 3 seconds  X seconds

Antenna polarization:

 vertical  horizontal

Test distance:

 1m  3m

EUT position:

     

Observation of EUT:

Via video camera

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

test level 1 test level 2 test level 3 test level x

front side rear side left side right side top bottom

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 29 of 62

Photo documentation

Picture 13: Test setup of radiated immunity test

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 30 of 62

Test result The requirements according to EN 61000-4-3 are



Kept



Not Kept

Information about measurement uncertainty is on page 61.

Operating conditions during test: Criterion

 A

During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

 B

During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

 C

During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.

Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 31 of 62

9. Electrical fast transient (EFT)/burst immunity test according to EN 61000-4-4

Location of measurement Description

Manufacturer

Inventory No.

Shielded chamber

Siemens - Matsushita

E000107

Measurement equipment Description

Manufacturer

Inventory No.

 Transient 2000

EMC Partner

E00045

 UCS 500 M4

EM Test

E00169

 Coupling clamp

Schaffner

E00046

 CDN 1000 network

EMC Partner

E00050

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 32 of 62

Test conditions Direct coupling of the test voltage to AC power supply ports / terminals Test voltage:

 0.5 kV  1 kV  2 kV  4 kV

Polarity:

 positive  negative

Coupling sort:

 symmetrical  unsymmetrical

Test duration:

60 seconds (for each test voltage)

Description of cable:

Standard power cord AC of the EUT

5.0 kHz 5.0 kHz 5.0 kHz 2.5 kHz

test level 1 test level 2 test level 3 test level 4

Direct coupling of the test voltage to DC power supply ports / terminals Test voltage:

 0.5 kV  1 kV  2 kV  4 kV

Polarity:

 positive  negative

Coupling sort:

 symmetrical  unsymmetrical

Test duration:

60 seconds (for each test voltage)

5.0 kHz 5.0 kHz 5.0 kHz 2.5 kHz

test level 1 test level 2 test level 3 test level 4

Description of cable:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 33 of 62

Direct coupling of the test voltage to signal-, data- and control lines Test voltage:

 0.25 kV  0.5 kV  1 kV  2 kV

Polarity:

 positive  negative

Coupling sort:

 symmetrical  unsymmetrical  capacitive

Test duration:

60 seconds (for each test voltage)

5.0 kHz 5.0 kHz 5.0 kHz 5.0 kHz

test level 1 test level 2 test level 3 test level 4

Description of cable:

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 34 of 62

Photo documentation

Picture 14: Test setup Burst

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 35 of 62

Test result The requirements according to EN 61000-4-4 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Operating conditions during test: Criterion

 A

During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

 B

During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

 C

During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.

Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 36 of 62

10. Surge immunity test according to EN 61000-4-5

Location of measurement Description

Manufacturer

Inventory No.

Shielded chamber

Siemens - Matsushita

E00107

Measurement equipment Description

Manufacturer

Inventory No.

 Transient 2000

EMC Partner

E00045

 UCS 500 M4

EM Test

E00169

 CDN 1000 network

EMC Partner

E00050

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 37 of 62

Test conditions Test voltage: Test impulse on phase and neutral (symmetrical)

   

0.5 kV 1 kV 2 kV 4 kV

test level 1 test level 2 test level 3 test level 4

Test impulse on phase, neutral and protective earth: (unsymmetrical)

   

0.5 kV 1 kV 2 kV 4 kV

test level 1 test level 2 test level 3 test level 4

Test impulse on signal and control cables: (symmetrical)

   

0.5 kV 1 kV 2 kV 4 kV

test level 1 test level 2 test level 3 test level 4

Test impulse on signal and control cables: (unsymmetrical)

   

0.5 kV 1 kV 2 kV 4 kV

test level 1 test level 2 test level 3 test level 4

Shield and frame/cabinet:

   

0.5 kV 1 kV 2 kV 4 kV

test level 1 test level 2 test level 3 test level 4

Polarity

 positive

 negative

Synchronizing angle Of test pulse:

 0°  180°

 90°  270°

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 38 of 62

Amount of test pulses: (for each test point and synchronizing angle)

 5 pulses

Pulse repeat frequency:

 1 pulse per minute

Triggering:

 intern  extern

Source impedance Of generator:

 2  (2 + 10)   (2 + 40) 

Connecting points:

   

Test equipment:

 Capacitive coupling network  coupling-/decoupling device

Description of tested cable:

Standard power cord AC of the EUT

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

Power cord AC Power cord DC Signal- and control cables Cabinet

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 39 of 62

Photo documentation

Picture 15: Test setup Surge

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 40 of 62

Test result The requirements according to EN 61000-4-5 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Operating conditions during test: Criterion

 A

During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

 B

During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

 C

During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.

Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 41 of 62

11. Immunity to conducted disturbances, induced by radio-frequency fields according to EN 61000-4-6

Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.

Measurement Equipment Description

Manufacturer

Inventory No.

 SMT06

Rohde & Schwarz

E00036

 BTA 0122-150W

Bonn

E00071

 NRVD

Rohde & Schwarz

E00038

 GAX1260/75

Dr. Hubert

E00332

 50FH-010-30

JFW

E00062

 Trilithic 10 dB 10W

Trilithic

E00355

 F-120-9B

FCC

E00063

 CDN M2

Erika Fiedler

E00065

 CDN M3

Erika Fiedler

E00066

 ENY 41

Rohde & Schwarz

E00042

 ENY 22

Rohde & Schwarz

E00041

 COSF 3312

Conformitas

E00037

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 42 of 62

Test conditions Frequency range:

 150 kHz - 80 MHz  150 kHz - 230 MHz

Step size:

 1 % of output frequency  4 % of output frequency

Test Voltage:

 1V  3V  10 V  XV

Modulation:

Kind of modulation: AM Modulation factor: 80 % Modulation frequency: 1 kHz

Dwell time:

 3 seconds  X seconds

Description of tested cable:

Standard power cord AC of the EUT with CDN M3

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

test level 1 test level 2 test level 3 test level

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 43 of 62

Photo documentation

Picture 16: Test setup induced RF

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 44 of 62

Test result The requirements according to EN 61000-4-6 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Operating conditions during test: Criterion

 A

During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

 B

During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

 C

During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.

Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 45 of 62

12. Voltage dips, short interruptions and voltage variations immunity tests according to EN 61000-4-11

Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.

Measurement equipment Description  Sycore / PAS5000 / ARS 16/3 / NT5000

Manufacturer

Inventory No.

S&S

E00058

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 46 of 62

Test conditions Voltage dips and short interruptions:

Test level

Voltage dips and short interruptions

Duration (in periods)

0 % UN

10 % UN

 0,5  10

 1  25

 5  50

70 % UN

30 % UN

 0,5  10

 1  25

 5  50

Phase of output voltage:

 0°  180°

Interruptions per test voltage and -duration:

 3 interruptions  interruptions

Time between Interruptions:

 10 seconds  seconds

Tested power supply system:

 single-phase system  three-phase system

Climatic conditions:

 45°  225°

 90°  270°

Ambient temp.: Relative humidity.: Barometric pressure:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

 135°  315°

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 47 of 62

Photo documentation

Picture 17: Test setup voltage dips

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 48 of 62

Test result The requirements according to EN 61000-4-11 are



Kept



Not kept

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 49 of 62

Operating conditions during test:

Test value:

Required criterion:

Operating condition during test

0 % during 1/2 period

min. criterion B

criterion A

70 % during 10 periods

min. criterion C

criterion A

Criterion

A

During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

B

During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

C

During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.

Comments: During the test the function of the EUT was observed. Influences in any form or program interruptions did not occur.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 50 of 62

13. Testing of harmonics current emission (equipment input current  16 A per phase) according to EN 61000-3-2

Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.

Measurement equipment Description  Sycore / PAS5000 / ARS 16/3 / NT5000

Manufacturer

Inventory No.

S&S

E00058

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 51 of 62

Test conditions Power supply frequency:

 50 Hz

Power supply voltage:

230 V

Tested power supply systems:

 single-phase system  three-phase system

Test duration:

2.50 minutes

Device class:

 A

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

 60 Hz

 B

 C

21 44 98

 D

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 52 of 62

Photo documentation

Picture 18: Test setup harmonics current emission

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 53 of 62

Device: Specimen: Manufacturer: Type:

Comment3: Comment4: Date: Test date:

21.06.2012 21.06.2012

Maximum RMS current and corresponding values in timewindow 416: Voltage: Current: Power: Powerfactor:

230.74 Vrms 0.576 Arms 126.5 W 0.952

Testconditions:

EN 61000-3-2:2000+A2, f=50 Hz, Phase=L1, Range=4.00 A, Rated fundamental / pf: 0.248 A, 0.98, No Ztest selected Time window cycles=10/12 (200ms), Grouping of harmonics=on

P1=126.6 W CosPhi1: 0.961

THD=0.05 % THD=12.83 % 132.9 VA

THV=0.121 V THC=0.073 A

POHV=0.031 V POHC=0.004 A

PWHD=0.09 % PWHD=4.21 %

HARMONIC ANALYSIS: Test PASS Tobs = entire measurement; POHC: avg=0.00 A, limits=0.05 A; Rated I1/Pf exceeded, changed to 0.57 A/0.980 Entire measurement (2.5 min = 750 time windows) Ha

DC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Maximum

0.0141 0.5709 0.0067 0.0756 0.0013 0.0205 0.0010 0.0062 0.0007 0.0020 0.0007 0.0012 0.0004 0.0016 0.0005 0.0018 0.0004 0.0017 0.0003 0.0016 0.0004 0.0016 0.0003 0.0016 0.0003 0.0014 0.0003 0.0014 0.0002 0.0013 0.0003 0.0013 0.0003 0.0013 0.0002 0.0013 0.0002 0.0012 0.0002 0.0012 0.0002

Window

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

528 416 241 4 130 23 185 146 188 371 187 446 185 736 131 692 189 739 189 728 131 739 184 746 131 164 414 162 130 681 131 739 241 747 240 744 130 741 415 454 130

EN61000-3-2 Class C a) -.- - - -.- - - 0.0114 A 0.1678 A -.- - - 0.0571 A -.- - - 0.0400 A -.- - - 0.0285 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - 0.0171 A -.- - - -

Worst 2.5 min

Margin in MaxWin

100 to 150%

Exceeded

100 to 150%

Exceeded

-- -.-- -.-41.2 % -55.0 % -- -.-64.0 % -- -.-84.5 % -- -.-92.9 % -- -.-93.0 % -- -.-90.8 % -- -.-89.2 % -- -.-90.0 % -- -.-90.4 % -- -.-90.6 % -- -.-90.9 % -- -.-92.1 % -- -.-91.6 % -- -.-92.1 % -- -.-92.6 % -- -.-92.5 % -- -.-92.5 % -- -.-92.8 % -- -.-93.1 % -- -.-

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e.

n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e. n.e.

Average Value

-0.0129 A 0.5614 A 0.0021 A 0.0686 A 0.0007 A 0.0184 A 0.0003 A 0.0055 A 0.0004 A 0.0014 A 0.0004 A 0.0009 A 0.0002 A 0.0013 A 0.0003 A 0.0015 A 0.0003 A 0.0015 A 0.0002 A 0.0014 A 0.0003 A 0.0013 A 0.0002 A 0.0013 A 0.0002 A 0.0012 A 0.0002 A 0.0013 A 0.0002 A 0.0012 A 0.0002 A 0.0012 A 0.0002 A 0.0012 A 0.0001 A 0.0012 A 0.0002 A 0.0012 A 0.0002 A 0.0011 A 0.0001 A

Exceeded

P A S S

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

F A I L

Geprüft mi t EMC tes t s oft ware V2. 41c / PA S 5000 v on Spi tzenberger + S pies GmbH & Co. KG, Sc hmi ds tr 32-34, D-94234 Vi echt ac h, 21. 06. 2012

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 54 of 62

Test result The requirements according to EN 61000-3-2 are



Kept



Not kept

Information about measurement uncertainty is on page 61.

Comments:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 55 of 62

14. Testing of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems (equipment input current  16 A per phase) according to EN 61000-3-3

Location of measurement In the EMV TESTHAUS GmbH the following measurement equipment was selected according to the climatic and electromagnetic general conditions of the above mentioned standard.

Measurement equipment Description  Sycore / PAS5000 / ARS 16/3 / NT5000

Manufacturer

Inventory No.

S&S

E00058

Test related measurement inaccuracies have to be taken into consideration when evaluating the test results. All used test instrument as well as the test accessories are calibrated at regular intervals.

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 56 of 62

Test conditions Power supply frequency:

 50 Hz

Tested power supply system

 single-phase system  three-phase system

Test duration:

10 minutes

Short timer flicker value Pst:

0.0520

Steady-state voltage change dc:

-.----- %

Maximum voltage change dmax:

0.127 %

Voltage change characteristic d(t):

0.000 %

Climatic conditions:

Ambient temp.: Relative humidity.: Barometric pressure:

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.3

 60 Hz

21 44 98

°C % kPa

Saint-Gobain Sekurit Deutschland GmbH & Co. KG SMPS 110VAC S 80VA U Power Supply 110423-AU02+E01

Page 57 of 62

Company: Test report no: Device: Specimen: Manufacturer: Type:

EMV TESTHAUS GmbH

Comment1: Comment2: Comment3: Comment4: Date: Test date:

21.06.2012 20.06.2012

Testconditions: EN 61000-3-3:1995+A1+A2 / 230 V / 50 Hz / Phase L1 / Obs 1 x 10 min / Ztest (0.400+j0.250 FLICKER: Test PASS! Time

Pmax

15:49:05

0.005

Limits:

Pst

Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL

0.0520

-. --- -

0.000

0.127 - . - - -

1.000

0.650

0.500

4.000

X

3.300

Plt: 0.052000

X

Evaluated: PST, PLT, Sliding PLT, dc, dmax, d(t)

FLICKER: Source test PASS! Time

Pmax

15:49:05

0.000

Pst 0.0100

Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL -. --- -

0.000

0.090 - . - - -

X

Plt: 0.010000 Evaluated: PST