Report No.:SZEE090603400212

Page 1 of 36

EMC TEST REPORT Product Name

:

Trade Name

:

LED STREET LIGHT

JRA1-160, JRA1-120, JRA1-90 JRA1-60, JRA1-30, JRX-Y90, JRX-Y120 Serial Number : N/A Technical Data : Input Voltage: AC100-240V 50/60Hz Report Number : SZEE090603400212 Date : Jul. 29, 2009 Regulations : See below Standards Results PASS EN 55015: 2006+A1:2007 PASS EN 61000-3-2: 2006 PASS EN 61000-3-3: 2008 PASS EN 61547:1995+A1:2000 PASS IEC 61000-4-2: 2008 PASS IEC 61000-4-3: 2006+A1:2007 PASS IEC 61000-4-4: 2004 PASS IEC 61000-4-5: 2005 PASS IEC 61000-4-6: 2008 IEC 61000-4-11: 2004 PASS Model Name

:

Prepared for:

ZHEJIANG JINGRI LIGHTING TECHNOLOGY CO., LTD. #2008 XISHAN ROAD, EASTERN NEW AREA, HUZHOU, ZHEJIANG TEL: +86-572-2283 082 FAX: +86-572-2042 887 Prepared by:

CENTRE TESTING INTERNATIONAL CORPORATION Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen, Guangdong, China TEL: +86-755-3368 3668 FAX: +86-755-3368 3385 This report shall not be reproduced, except in full, without the written approval of CENTRE TESTING INTERNATIONAL CORPORATION Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen

Report No.:SZEE090603400212

Page 2 of 36

TABLE OF CONTENTS

1.

GENERAL INFORMATION ..................................................................................4

2.

TEST SUMMARY .................................................................................................5

3.

MEASUREMENT UNCERTAINTY .......................................................................5

4.

PRODUCT INFORMATION AND TEST SETUP ..................................................6 4.1 4.2 4.3

5.

FACILITIES AND ACCREDITATIONS.................................................................6 5.1 5.2 5.3

6.

PRODUCT INFORMATION .......................................................................6 TEST SETUP CONFIGURATION ..............................................................6 SUPPORT EQUIPMENT............................................................................6 TEST FACILITY .........................................................................................6 TEST EQUIPMENT LIST ...........................................................................6 LABORATORY ACCREDITATIONS AND LISTINGS ...............................7

DISTURBANCE VOLTAGES AT MAINS TERMINALS (CE) ...............................8 6.1 6.2 6.3 6.4

LIMITS .......................................................................................................8 BLOCK DIAGRAM OF TEST SETUP .......................................................8 TEST PROCEDURE ..................................................................................8 TEST RESULTS ........................................................................................9

7. RADIATED DISTURBANCE (9KHz-30MHz) ............................................................11 7.1 LIMITS OF RADIATED DISTURBANCE (9KHZ-30MHZ) ............................11 7.2 TEST SETUP ................................................................................................11 7.3 TEST PROCEDURE .....................................................................................11 7.4 TEST RESULTS ...........................................................................................12 8. RADIATED DISTURBANCE (30MHz -300MHz) .......................................................15 8.1 LIMITS OF RADIATED DISTURBANCE (30MHz -300MHz)........................15 8.2 TEST SETUP ................................................................................................15 8.3 TEST PROCEDURE .....................................................................................15 8.4 TEST RESULTS ...........................................................................................16 9. HARMONIC CURRENT EMISSION (HARMONIC) ...................................................18 9.1 LIMITS OF HARMONIC CURRENT EMISSION MEASUREMENT..............18 9.2 TEST SETUP ................................................................................................18 9.3 TEST PROCEDURE .....................................................................................18 9.4 TEST RESULTS ...........................................................................................18 10. VOLTAGE FLUCTUATIONS & FLICKER TEST(FLICKER)...................................21 10.1 LIMITS OF VOLTAGE FLUCTUATIONS & FLICKER ...............................21 10.2 TEST SETUP ..............................................................................................21 10.3 TEST PROCEDURE ...................................................................................21 10.4 TEST RESULTS .........................................................................................21

Report No.:SZEE090603400212

Page 3 of 36

11. IMMUNITY TEST .....................................................................................................23 11.1 GENERAL PERFORMANCE CRITERIA DESCRIPTION ..........................23 11.2 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD) ........................24 11.2.1 TEST SPECIFICATION.................................................................24 11.2.2 TEST SETUP ................................................................................24 11.2.3 TEST PROCEDURE .....................................................................24 11.2.4 RESULT & PERFORMANCE .......................................................25 11.3 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS) .............................................................................26 11.3.1 TEST SPECIFICATION.................................................................26 11.3.2 TEST SETUP ................................................................................26 11.3.3 TEST PROCEDURE .....................................................................26 11.3.4 RESULT & PERFORMANCE .......................................................26 11.4 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (EFT) .........27 11.4.1 TEST SPECIFICATION.................................................................27 11.4.2 TEST SETUP ................................................................................27 11.4.3 TEST PROCEDURE .....................................................................27 11.4.4 RESULT & PERFORMANCE .......................................................27 11.5 SURGE IMMUNITY TEST (SURGE) ..........................................................28 11.5.1 TEST SPECIFICATION.................................................................28 11.5.2 TEST SETUP ................................................................................28 11.5.3 TEST PROCEDURE .....................................................................28 11.5.4 RESULT & PERFORMANCE .......................................................28 11.6 IMMUNITY TO CONDUCTED DISTURBANCES INDUCED BY RF FIELDS (CS) ............................................................................................29 10.6.1 TEST SPECIFICATION.................................................................29 11.6.2 TEST SETUP ................................................................................29 11.6.3 TEST PROCEDURE .....................................................................29 11.6.4 RESULT & PERFORMANCE .......................................................29 11.7 VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST ..............................................................30 11.7.1 TEST SPECIFICATION.................................................................30 11.7.2 TEST SETUP ................................................................................30 11.7.3 TEST PROCEDURE .....................................................................30 11.7.4 RESULT & PERFORMANCE .......................................................30 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP .......................................................31 APPENDIX 2 PHOTOGRAPHS OF EUT ......................................................................36 (Note: N/A means not applicable)

Report No.:SZEE090603400212

Page 5 of 36

2. TEST SUMMARY The EUT has been tested according to the following specifications: EMISSION Standard

Test Item

Test

EN 55015

Insertion loss

N/A

EN 55015

Disturbance voltages at mains terminals

EN 55015

Disturbance voltages at load terminals

N/A

EN 55015

Disturbance voltages at control terminals

N/A

EN 55015

Radiated disturbance in frequency range 9KHz to 30MHz

PASS

EN 55015

Radiated disturbance in frequency range 30MHz to 300MHz

PASS

EN 61000-3-2

Harmonic current emission

PASS

EN 61000-3-3

Voltage fluctuations & flicker

PASS

PASS

IMMUNITY (EN 61547) Standard

Test Item

Test

IEC 61000-4-2

Electrostatic discharge immunity

PASS

IEC 61000-4-3

Radiated, radio frequency, electromagnetic field immunity

PASS

IEC 61000-4-4

Electrical fast transient / burst immunity

PASS

IEC 61000-4-5

Surge immunity

PASS

IEC 61000-4-6

Immunity to conducted disturbances, induced by radio-frequency fields

PASS

IEC 61000-4-11

Voltage dips, short interruptions and voltage variations immunity

PASS

3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Test item

Value

CE

3.6 dB

RE

4.6 dB

Report No.:SZEE090603400212

Page 6 of 36

4. PRODUCT INFORMATION AND TEST SETUP 4.1 PRODUCT INFORMATION Input Voltage: AC100-240V 50/60Hz Technical Data: The model numbers of EUT are JRA1-160, JRA1-120, JRA1-90, JRA1-60, JRA1-30, JRX-Y90, JRX-Y120. All the models are the same except the power and the appearance. The power of JRA1-160 is 160W. The power of JRA1-120 is 120W. The power of JRA1-90 is 90W. The power of JRA1-60 is 60W. The power of JRA1-30 is 30W. The power of JRX-Y90 is 90W. The power of JRX-Y120 is 120W. The model number of test sample is JRA1-160, and the test results are applicable to the others. 4.2 TEST SETUP CONFIGURATION 1. Test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. 2. Make sure the EUT work normally during the test. 4.3 SUPPORT EQUIPMENT No.

Device Type

Brand

Model

Series No.

Data Cable

Power Cord

1.

---

---

---

---

---

---

Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use.

5. FACILITIES AND ACCREDITATIONS 5.1 TEST FACILITY All measurement facilities used to collect the measurement data are located at Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen, Guangdong, China. The site and apparatus are constructed in conformance with the requirements of ANSI C63.4 and CISPR 16-1-1 other equivalent standards. 5.2 TEST EQUIPMENT LIST Instrumentation: The following list contains equipments used at CTI for testing. The calibrations of the measuring instruments, including any accessories that may effect such calibration, are checked frequently to assure their accuracy. Adjustments are made and correction factors applied in accordance with instructions contained in the manual for the measuring instrument. Equipment used during the tests: Shielding Room No. 1 - CE Test Equipment

Manufacturer

Model

Serial No.

Due Date

Receiver

R&S

ESCI

100435

01/29/2010

LISN

R&S

ENV216

100098

06/13/2010

Shielding Room No. 1 - ME Test Equipment

Manufacturer

Model

Serial No.

Due Date

Receiver

R&S

ESCI

100435

01/29/2010

3-Loop Antenna

LAPLACE

RF300

E011

06/13/2010

Report No.:SZEE090603400212

Page 7 of 36

3M Semi-anechoic Chamber - RE Test Equipment 3M Chamber & Accessory Equipment Spectrum Analyzer

Manufacturer

Model

Serial No.

Due Date

ETS-LINDGREN

FACT-3

3510

01/29/2010

Agilent

E4443A

MY46185649

01/29/2010

Multi device Controller

ETS-LINGREN

2090

00057230

01/29/2010

Shielding Room No. 2 - Harmonic / Flicker Test (EN 61000-3-2) (EN 61000-3-3) Equipment 5KVA AC POWER SOURCE

Manufacturer Model Serial No. California 500LIX 57344 instruments California Flicker & Harmonic Tester 413 OPITION 72492 instruments Shielding Room No. 3 - ESD Test (IEC 61000-4-2)

Due Date 01/29/2010 01/29/2010

Equipment

Manufacturer

Model

Serial No.

Due Date

ESD Simulator

SCHAFFNER

NSG438

230

12/17/2009

3M Full-anechoic Chamber - RS Test (IEC 61000-4-3) Equipment ESG Vector signal generators Power Amplifier

Manufacturer

Model

Agilent

E4438C

AR

150W1000

Serial No. MY4509 5744 0322288

Due Date 12/17/2009 01/29/2010

Shielding Room No. 3 - EFT / Surges Test (IEC 61000-4-4) (IEC 61000-4-5) Equipment

Manufacturer

Model

Serial No.

Due Date

Compact Generator

EM-Test

UCS500M/6B

V0603101093

09/07/2009

Shielding Room No. 2 - CS Test (IEC 61000-4-6) Equipment

Manufacturer

Model

Serial No.

Due Date

Signal Generator

IFR

2023B

202307/439

11/19/2009

Power Amplifier

AR

75A250A

329207

06/07/2010

CDN

EM-Test

CDN M2/M3

0204-01

06/07/2010

Shielding Room No. 2 - Dips Test (IEC 61000-4-11) Equipment 5KVA AC POWER SOURCE Electronic output switch

Manufacturer California instruments California instruments

Model

Serial No.

Due Date

500LIX

57344

01/29/2010

EOS-1

72616

01/29/2010

5.3 LABORATORY ACCREDITATIONS AND LISTINGS The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025 to international or national standards. Equipment has been calibrated by accredited calibration laboratories.

Report No.:SZEE090603400212

Page 8 of 36

6. DISTURBANCE VOLTAGES AT MAINS TERMINALS (CE) 6.1 LIMITS Limits (dBμV)

Frequency range (MHz)

Quasi-peak

Average

0,009 to 0,05

110

--

0.05 to 0.15

90 to 80

--

0,15 to 0,50

66 to 56

56 to 46

0,50 to 5

56

46

5 to 30

60

50

NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.05 to 0.50 MHz. 3. For electrodeless lamps and luminaires, the limit in the frequency range of 2.51MHz to 3MHz is 73 dB(μV) quasi-peak and 63 dB(μV) average.

6.2 BLOCK DIAGRAM OF TEST SETUP

6.3 TEST PROCEDURE a. The EUT was placed on a non-conductive table 0.8 m above the horizontal ground reference plane, and 0.4 m from the vertical ground reference plane, and connected to the main through Line Impedance Stability Network (L.I.S.N). b. The RBW of the receiver was set at 200Hz in 9 kHz -150 kHz and 9 kHz in 150 kHz 30MHz with Peak and AVG detector in Max Hold mode. Run the receiver’s pre-scan to record the maximum disturbance generated from EUT in all power lines in the full band. c. For each frequency whose maximum record was higher or close to limit, measure its QP and AVG values and record.

Report No.:SZEE090603400212

6.4 TEST RESULTS EUT : Power : Mode :

Page 9 of 36

LED STREET LIGHT AC 230V/50Hz Normal

M/N Temperature Humidity

JRA1-160 24℃ 53%

: : :

CE Test Result Reading Level (dBuV)

Measurement (dBuV)

Limit (dBuV)

Margin (dB)

Peak

Q.P.

Avg.

Correct Factor (dB)

Peak

Q.P.

Avg.

Q.P.

Avg.

Q.P.

Avg.

0.1780

55.65

51.06

36.50

9.95

65.60

61.01

46.45

64.57

54.57

-3.56

-8.12

0.2740

46.80

45.72

36.08

9.94

56.74

55.66

46.02

60.99

50.99

-5.33

-4.97

0.4700

41.14

40.69

26.85

9.94

51.08

50.63

36.79

56.51

46.51

-5.88

-9.72

0.6580

38.14

37.25

21.95

9.79

47.93

47.04

31.74

56.00

46.00

-8.96

-14.26

0.1819

57.23

51.40

37.69

9.95

67.18

61.35

47.64

64.39

54.39

-3.04

-6.75

0.2540

48.31

46.88

38.22

9.94

58.25

56.82

48.16

61.62

51.62

-4.80

-3.46

0.4700

42.39

41.99

27.11

9.94

52.33

51.93

37.05

56.51

46.51

-4.58

-9.46

0.6580

39.11

38.37

21.55

9.79

48.90

48.16

31.34

56.00

46.00

-7.84

-14.66

Frequency (MHz)

Frequency Reading level Correct Factor Measurement Limit (dBuV) Margin(dB) “--“

Result Remarks (P/F) (L/N) P P P P

L L L L

P P P P

N N N N

= Emission frequency in MHz = Uncorrected receiver reading = Cable loss + LISN inserting loss = Reading level + Factor = Limit stated in standard = Reading in reference to limit = The emission level complied with the Average limits, with at least 2 dB margin, so no further recheck.

Report No.:SZEE090603400212

Graphs of Conduction Emission: L:

N:

Page 10 of 36

Report No.:SZEE090603400212

Page 11 of 36

7. RADIATED DISTURBANCE (9KHz-30MHz) 7.1 LIMITS OF RADIATED DISTURBANCE (9KHZ-30MHZ) Frequency 9KHz ~ 70KHz 70KHz ~ 150KHz 150KHz ~ 3.0MHz 3.0MHz ~ 30MHz

Limits for Loop Diameter (dBμA) 2m 88 88 ~ 58* 58 ~ 22* 22

NOTE: (1) At the transition frequency the lower limit applies. (2) * means decreasing linearly with logarithm of the frequency. For electrodeless lamps And luminaires ,the limit in the frequency range of2.2MHz to 3.0MHz is 58 dB(μA) for 2m,51 dB(μA) for 3m and 45dB(μA) for 4m loop diameter. 7.2 TEST SETUP

7.3 TEST PROCEDURE a. The EUT was placed on a wooden table in the center of a loop antenna. b. The induced current in the loop antenna was measured by means of a current probe and the test receiver. Three field components were checked by means of a coaxial switch. c. The frequency range from 9 KHz to 30MHz is investigated. The receiver is measured with the quasi-peak detector. For frequency band 9 KHz to 150 KHz, the bandwidth of the field strength meter (R & S test receiver ESCI is set at 200Hz. For frequency band 150 KHz to 30MHz, the bandwidth is set at 9 KHz.

Report No.:SZEE090603400212

Page 12 of 36

7.4 TEST RESULTS EUT Power Mode Frequency (MHz)

LED STREET LIGHT AC 230V/50Hz Normal

: : :

Reading Level (dBuA)

0.0365 0.2220

Peak -33.20 -22.13

Q.P. ---

Avg. ---

0.0364 0.0728 0.1106 0.2220

-23.60 -32.55 -32.09 -21.70

-----

0.1018

-33.71

0.2220

-22.28

0.2740

-27.82

Correct Factor (dB)

M/N Temperature Humidity

Measurement (dBuA)

38.28 28.53

Peak 5.08 6.40

Q.P. ---

-----

38.31 34.25 31.54 28.53

14.71 1.70 -0.55 6.83

-----

-----

--

--

31.78

-1.93

--

--

--

28.53

6.25

--

--

--

27.12

-0.70

--

Frequency Reading level Correct Factor Measurement Limit (dBuA) Margin (dB) PK QP

Limit (dBuA)

Avg. Q.P. -88.00 -53.28

JRA1-160 24℃ 53%

: : : Margin (dB)

Result (P/F)

Remarks (X/Y/Z)

P P

X X

Avg. ---

Q.P.