Report No.:SZEE090603400212
Page 1 of 36
EMC TEST REPORT Product Name
:
Trade Name
:
LED STREET LIGHT
JRA1-160, JRA1-120, JRA1-90 JRA1-60, JRA1-30, JRX-Y90, JRX-Y120 Serial Number : N/A Technical Data : Input Voltage: AC100-240V 50/60Hz Report Number : SZEE090603400212 Date : Jul. 29, 2009 Regulations : See below Standards Results PASS EN 55015: 2006+A1:2007 PASS EN 61000-3-2: 2006 PASS EN 61000-3-3: 2008 PASS EN 61547:1995+A1:2000 PASS IEC 61000-4-2: 2008 PASS IEC 61000-4-3: 2006+A1:2007 PASS IEC 61000-4-4: 2004 PASS IEC 61000-4-5: 2005 PASS IEC 61000-4-6: 2008 IEC 61000-4-11: 2004 PASS Model Name
:
Prepared for:
ZHEJIANG JINGRI LIGHTING TECHNOLOGY CO., LTD. #2008 XISHAN ROAD, EASTERN NEW AREA, HUZHOU, ZHEJIANG TEL: +86-572-2283 082 FAX: +86-572-2042 887 Prepared by:
CENTRE TESTING INTERNATIONAL CORPORATION Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen, Guangdong, China TEL: +86-755-3368 3668 FAX: +86-755-3368 3385 This report shall not be reproduced, except in full, without the written approval of CENTRE TESTING INTERNATIONAL CORPORATION Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen
Report No.:SZEE090603400212
Page 2 of 36
TABLE OF CONTENTS
1.
GENERAL INFORMATION ..................................................................................4
2.
TEST SUMMARY .................................................................................................5
3.
MEASUREMENT UNCERTAINTY .......................................................................5
4.
PRODUCT INFORMATION AND TEST SETUP ..................................................6 4.1 4.2 4.3
5.
FACILITIES AND ACCREDITATIONS.................................................................6 5.1 5.2 5.3
6.
PRODUCT INFORMATION .......................................................................6 TEST SETUP CONFIGURATION ..............................................................6 SUPPORT EQUIPMENT............................................................................6 TEST FACILITY .........................................................................................6 TEST EQUIPMENT LIST ...........................................................................6 LABORATORY ACCREDITATIONS AND LISTINGS ...............................7
DISTURBANCE VOLTAGES AT MAINS TERMINALS (CE) ...............................8 6.1 6.2 6.3 6.4
LIMITS .......................................................................................................8 BLOCK DIAGRAM OF TEST SETUP .......................................................8 TEST PROCEDURE ..................................................................................8 TEST RESULTS ........................................................................................9
7. RADIATED DISTURBANCE (9KHz-30MHz) ............................................................11 7.1 LIMITS OF RADIATED DISTURBANCE (9KHZ-30MHZ) ............................11 7.2 TEST SETUP ................................................................................................11 7.3 TEST PROCEDURE .....................................................................................11 7.4 TEST RESULTS ...........................................................................................12 8. RADIATED DISTURBANCE (30MHz -300MHz) .......................................................15 8.1 LIMITS OF RADIATED DISTURBANCE (30MHz -300MHz)........................15 8.2 TEST SETUP ................................................................................................15 8.3 TEST PROCEDURE .....................................................................................15 8.4 TEST RESULTS ...........................................................................................16 9. HARMONIC CURRENT EMISSION (HARMONIC) ...................................................18 9.1 LIMITS OF HARMONIC CURRENT EMISSION MEASUREMENT..............18 9.2 TEST SETUP ................................................................................................18 9.3 TEST PROCEDURE .....................................................................................18 9.4 TEST RESULTS ...........................................................................................18 10. VOLTAGE FLUCTUATIONS & FLICKER TEST(FLICKER)...................................21 10.1 LIMITS OF VOLTAGE FLUCTUATIONS & FLICKER ...............................21 10.2 TEST SETUP ..............................................................................................21 10.3 TEST PROCEDURE ...................................................................................21 10.4 TEST RESULTS .........................................................................................21
Report No.:SZEE090603400212
Page 3 of 36
11. IMMUNITY TEST .....................................................................................................23 11.1 GENERAL PERFORMANCE CRITERIA DESCRIPTION ..........................23 11.2 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD) ........................24 11.2.1 TEST SPECIFICATION.................................................................24 11.2.2 TEST SETUP ................................................................................24 11.2.3 TEST PROCEDURE .....................................................................24 11.2.4 RESULT & PERFORMANCE .......................................................25 11.3 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS) .............................................................................26 11.3.1 TEST SPECIFICATION.................................................................26 11.3.2 TEST SETUP ................................................................................26 11.3.3 TEST PROCEDURE .....................................................................26 11.3.4 RESULT & PERFORMANCE .......................................................26 11.4 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (EFT) .........27 11.4.1 TEST SPECIFICATION.................................................................27 11.4.2 TEST SETUP ................................................................................27 11.4.3 TEST PROCEDURE .....................................................................27 11.4.4 RESULT & PERFORMANCE .......................................................27 11.5 SURGE IMMUNITY TEST (SURGE) ..........................................................28 11.5.1 TEST SPECIFICATION.................................................................28 11.5.2 TEST SETUP ................................................................................28 11.5.3 TEST PROCEDURE .....................................................................28 11.5.4 RESULT & PERFORMANCE .......................................................28 11.6 IMMUNITY TO CONDUCTED DISTURBANCES INDUCED BY RF FIELDS (CS) ............................................................................................29 10.6.1 TEST SPECIFICATION.................................................................29 11.6.2 TEST SETUP ................................................................................29 11.6.3 TEST PROCEDURE .....................................................................29 11.6.4 RESULT & PERFORMANCE .......................................................29 11.7 VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST ..............................................................30 11.7.1 TEST SPECIFICATION.................................................................30 11.7.2 TEST SETUP ................................................................................30 11.7.3 TEST PROCEDURE .....................................................................30 11.7.4 RESULT & PERFORMANCE .......................................................30 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP .......................................................31 APPENDIX 2 PHOTOGRAPHS OF EUT ......................................................................36 (Note: N/A means not applicable)
Report No.:SZEE090603400212
Page 5 of 36
2. TEST SUMMARY The EUT has been tested according to the following specifications: EMISSION Standard
Test Item
Test
EN 55015
Insertion loss
N/A
EN 55015
Disturbance voltages at mains terminals
EN 55015
Disturbance voltages at load terminals
N/A
EN 55015
Disturbance voltages at control terminals
N/A
EN 55015
Radiated disturbance in frequency range 9KHz to 30MHz
PASS
EN 55015
Radiated disturbance in frequency range 30MHz to 300MHz
PASS
EN 61000-3-2
Harmonic current emission
PASS
EN 61000-3-3
Voltage fluctuations & flicker
PASS
PASS
IMMUNITY (EN 61547) Standard
Test Item
Test
IEC 61000-4-2
Electrostatic discharge immunity
PASS
IEC 61000-4-3
Radiated, radio frequency, electromagnetic field immunity
PASS
IEC 61000-4-4
Electrical fast transient / burst immunity
PASS
IEC 61000-4-5
Surge immunity
PASS
IEC 61000-4-6
Immunity to conducted disturbances, induced by radio-frequency fields
PASS
IEC 61000-4-11
Voltage dips, short interruptions and voltage variations immunity
PASS
3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Test item
Value
CE
3.6 dB
RE
4.6 dB
Report No.:SZEE090603400212
Page 6 of 36
4. PRODUCT INFORMATION AND TEST SETUP 4.1 PRODUCT INFORMATION Input Voltage: AC100-240V 50/60Hz Technical Data: The model numbers of EUT are JRA1-160, JRA1-120, JRA1-90, JRA1-60, JRA1-30, JRX-Y90, JRX-Y120. All the models are the same except the power and the appearance. The power of JRA1-160 is 160W. The power of JRA1-120 is 120W. The power of JRA1-90 is 90W. The power of JRA1-60 is 60W. The power of JRA1-30 is 30W. The power of JRX-Y90 is 90W. The power of JRX-Y120 is 120W. The model number of test sample is JRA1-160, and the test results are applicable to the others. 4.2 TEST SETUP CONFIGURATION 1. Test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. 2. Make sure the EUT work normally during the test. 4.3 SUPPORT EQUIPMENT No.
Device Type
Brand
Model
Series No.
Data Cable
Power Cord
1.
---
---
---
---
---
---
Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use.
5. FACILITIES AND ACCREDITATIONS 5.1 TEST FACILITY All measurement facilities used to collect the measurement data are located at Building C, Hongwei Industrial Zone, Baoan 70 District, Shenzhen, Guangdong, China. The site and apparatus are constructed in conformance with the requirements of ANSI C63.4 and CISPR 16-1-1 other equivalent standards. 5.2 TEST EQUIPMENT LIST Instrumentation: The following list contains equipments used at CTI for testing. The calibrations of the measuring instruments, including any accessories that may effect such calibration, are checked frequently to assure their accuracy. Adjustments are made and correction factors applied in accordance with instructions contained in the manual for the measuring instrument. Equipment used during the tests: Shielding Room No. 1 - CE Test Equipment
Manufacturer
Model
Serial No.
Due Date
Receiver
R&S
ESCI
100435
01/29/2010
LISN
R&S
ENV216
100098
06/13/2010
Shielding Room No. 1 - ME Test Equipment
Manufacturer
Model
Serial No.
Due Date
Receiver
R&S
ESCI
100435
01/29/2010
3-Loop Antenna
LAPLACE
RF300
E011
06/13/2010
Report No.:SZEE090603400212
Page 7 of 36
3M Semi-anechoic Chamber - RE Test Equipment 3M Chamber & Accessory Equipment Spectrum Analyzer
Manufacturer
Model
Serial No.
Due Date
ETS-LINDGREN
FACT-3
3510
01/29/2010
Agilent
E4443A
MY46185649
01/29/2010
Multi device Controller
ETS-LINGREN
2090
00057230
01/29/2010
Shielding Room No. 2 - Harmonic / Flicker Test (EN 61000-3-2) (EN 61000-3-3) Equipment 5KVA AC POWER SOURCE
Manufacturer Model Serial No. California 500LIX 57344 instruments California Flicker & Harmonic Tester 413 OPITION 72492 instruments Shielding Room No. 3 - ESD Test (IEC 61000-4-2)
Due Date 01/29/2010 01/29/2010
Equipment
Manufacturer
Model
Serial No.
Due Date
ESD Simulator
SCHAFFNER
NSG438
230
12/17/2009
3M Full-anechoic Chamber - RS Test (IEC 61000-4-3) Equipment ESG Vector signal generators Power Amplifier
Manufacturer
Model
Agilent
E4438C
AR
150W1000
Serial No. MY4509 5744 0322288
Due Date 12/17/2009 01/29/2010
Shielding Room No. 3 - EFT / Surges Test (IEC 61000-4-4) (IEC 61000-4-5) Equipment
Manufacturer
Model
Serial No.
Due Date
Compact Generator
EM-Test
UCS500M/6B
V0603101093
09/07/2009
Shielding Room No. 2 - CS Test (IEC 61000-4-6) Equipment
Manufacturer
Model
Serial No.
Due Date
Signal Generator
IFR
2023B
202307/439
11/19/2009
Power Amplifier
AR
75A250A
329207
06/07/2010
CDN
EM-Test
CDN M2/M3
0204-01
06/07/2010
Shielding Room No. 2 - Dips Test (IEC 61000-4-11) Equipment 5KVA AC POWER SOURCE Electronic output switch
Manufacturer California instruments California instruments
Model
Serial No.
Due Date
500LIX
57344
01/29/2010
EOS-1
72616
01/29/2010
5.3 LABORATORY ACCREDITATIONS AND LISTINGS The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025 to international or national standards. Equipment has been calibrated by accredited calibration laboratories.
Report No.:SZEE090603400212
Page 8 of 36
6. DISTURBANCE VOLTAGES AT MAINS TERMINALS (CE) 6.1 LIMITS Limits (dBμV)
Frequency range (MHz)
Quasi-peak
Average
0,009 to 0,05
110
--
0.05 to 0.15
90 to 80
--
0,15 to 0,50
66 to 56
56 to 46
0,50 to 5
56
46
5 to 30
60
50
NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.05 to 0.50 MHz. 3. For electrodeless lamps and luminaires, the limit in the frequency range of 2.51MHz to 3MHz is 73 dB(μV) quasi-peak and 63 dB(μV) average.
6.2 BLOCK DIAGRAM OF TEST SETUP
6.3 TEST PROCEDURE a. The EUT was placed on a non-conductive table 0.8 m above the horizontal ground reference plane, and 0.4 m from the vertical ground reference plane, and connected to the main through Line Impedance Stability Network (L.I.S.N). b. The RBW of the receiver was set at 200Hz in 9 kHz -150 kHz and 9 kHz in 150 kHz 30MHz with Peak and AVG detector in Max Hold mode. Run the receiver’s pre-scan to record the maximum disturbance generated from EUT in all power lines in the full band. c. For each frequency whose maximum record was higher or close to limit, measure its QP and AVG values and record.
Report No.:SZEE090603400212
6.4 TEST RESULTS EUT : Power : Mode :
Page 9 of 36
LED STREET LIGHT AC 230V/50Hz Normal
M/N Temperature Humidity
JRA1-160 24℃ 53%
: : :
CE Test Result Reading Level (dBuV)
Measurement (dBuV)
Limit (dBuV)
Margin (dB)
Peak
Q.P.
Avg.
Correct Factor (dB)
Peak
Q.P.
Avg.
Q.P.
Avg.
Q.P.
Avg.
0.1780
55.65
51.06
36.50
9.95
65.60
61.01
46.45
64.57
54.57
-3.56
-8.12
0.2740
46.80
45.72
36.08
9.94
56.74
55.66
46.02
60.99
50.99
-5.33
-4.97
0.4700
41.14
40.69
26.85
9.94
51.08
50.63
36.79
56.51
46.51
-5.88
-9.72
0.6580
38.14
37.25
21.95
9.79
47.93
47.04
31.74
56.00
46.00
-8.96
-14.26
0.1819
57.23
51.40
37.69
9.95
67.18
61.35
47.64
64.39
54.39
-3.04
-6.75
0.2540
48.31
46.88
38.22
9.94
58.25
56.82
48.16
61.62
51.62
-4.80
-3.46
0.4700
42.39
41.99
27.11
9.94
52.33
51.93
37.05
56.51
46.51
-4.58
-9.46
0.6580
39.11
38.37
21.55
9.79
48.90
48.16
31.34
56.00
46.00
-7.84
-14.66
Frequency (MHz)
Frequency Reading level Correct Factor Measurement Limit (dBuV) Margin(dB) “--“
Result Remarks (P/F) (L/N) P P P P
L L L L
P P P P
N N N N
= Emission frequency in MHz = Uncorrected receiver reading = Cable loss + LISN inserting loss = Reading level + Factor = Limit stated in standard = Reading in reference to limit = The emission level complied with the Average limits, with at least 2 dB margin, so no further recheck.
Report No.:SZEE090603400212
Graphs of Conduction Emission: L:
N:
Page 10 of 36
Report No.:SZEE090603400212
Page 11 of 36
7. RADIATED DISTURBANCE (9KHz-30MHz) 7.1 LIMITS OF RADIATED DISTURBANCE (9KHZ-30MHZ) Frequency 9KHz ~ 70KHz 70KHz ~ 150KHz 150KHz ~ 3.0MHz 3.0MHz ~ 30MHz
Limits for Loop Diameter (dBμA) 2m 88 88 ~ 58* 58 ~ 22* 22
NOTE: (1) At the transition frequency the lower limit applies. (2) * means decreasing linearly with logarithm of the frequency. For electrodeless lamps And luminaires ,the limit in the frequency range of2.2MHz to 3.0MHz is 58 dB(μA) for 2m,51 dB(μA) for 3m and 45dB(μA) for 4m loop diameter. 7.2 TEST SETUP
7.3 TEST PROCEDURE a. The EUT was placed on a wooden table in the center of a loop antenna. b. The induced current in the loop antenna was measured by means of a current probe and the test receiver. Three field components were checked by means of a coaxial switch. c. The frequency range from 9 KHz to 30MHz is investigated. The receiver is measured with the quasi-peak detector. For frequency band 9 KHz to 150 KHz, the bandwidth of the field strength meter (R & S test receiver ESCI is set at 200Hz. For frequency band 150 KHz to 30MHz, the bandwidth is set at 9 KHz.
Report No.:SZEE090603400212
Page 12 of 36
7.4 TEST RESULTS EUT Power Mode Frequency (MHz)
LED STREET LIGHT AC 230V/50Hz Normal
: : :
Reading Level (dBuA)
0.0365 0.2220
Peak -33.20 -22.13
Q.P. ---
Avg. ---
0.0364 0.0728 0.1106 0.2220
-23.60 -32.55 -32.09 -21.70
-----
0.1018
-33.71
0.2220
-22.28
0.2740
-27.82
Correct Factor (dB)
M/N Temperature Humidity
Measurement (dBuA)
38.28 28.53
Peak 5.08 6.40
Q.P. ---
-----
38.31 34.25 31.54 28.53
14.71 1.70 -0.55 6.83
-----
-----
--
--
31.78
-1.93
--
--
--
28.53
6.25
--
--
--
27.12
-0.70
--
Frequency Reading level Correct Factor Measurement Limit (dBuA) Margin (dB) PK QP
Limit (dBuA)
Avg. Q.P. -88.00 -53.28
JRA1-160 24℃ 53%
: : : Margin (dB)
Result (P/F)
Remarks (X/Y/Z)
P P
X X
Avg. ---
Q.P.