4/2015 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES • INDUSTRIAL CABLES • OPTICAL FIBRE CABLES • FLEXIBLE CABLES Contents Helkama – a tru...
Author: Constance Poole
21 downloads 4 Views 6MB Size
4/2015

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES • INDUSTRIAL CABLES • OPTICAL FIBRE CABLES • FLEXIBLE CABLES

Contents Helkama – a true specialist in marine cables..3 Approvals ..........................................................3 0,6/1kV cables LKM-HF..............................................................4 LKMM-HF ..........................................................8 LKSM-HF..........................................................10 LKMSM-HF .....................................................14 LKAM-HF..........................................................16 LKEM-HF..........................................................18 EMC cables LKSM-EMC ......................................................20 LKSM-EMC-FRHF.............................................24 RFE-EMC..........................................................28 RFE-EMC(i) ......................................................30 1,8/3kV cables LKSM-VFD .......................................................32 0,6/1kV FR cables LKM-FRHF........................................................34 LKSM-FRHF .....................................................38 LKAM-FRHF .....................................................42 250V cables LKM-HF ...........................................................44 LKSM-HF..........................................................46 LKAM-HF .........................................................48 RFE-HF.............................................................50 RFE-HF (i) ........................................................52 RFA-HF.............................................................54 RFA-HF (i) ........................................................56 Marine cable factory in Kaarina, Finland.

Marine cable factory in Shanghai, China.

250V FR cables LKM-FRHF .......................................................58 LKSM-FRHF ....................................................60 LKAM-FRHF ....................................................62 RFE-FRHF.........................................................64 RFE-FRHF (i) ....................................................66 RFA-FRHF ........................................................68 RFA-FRHF (i)....................................................70 Heat resistant cables 120°C NEW LKSM-SHF2 120°C 0,6/1kV .............................72 LKSM-SHF2 120°C 250V .................................76 RFE-SHF2 120°C 250V.....................................78 RFE-SHF2 (i) 120°C 250V ................................80 Optical fibre cables FXMSU.............................................................82 FXMMS ............................................................84 Cabled optical fibres characteristics.................86 Technical information General information .........................................88 Bending radius .................................................89 Diameter tolerance ...........................................89 Core identification ............................................89 Current rating...................................................90 Short circuit current.........................................91 Short time duty ................................................92 Voltage drop.....................................................93 Subject to change without prior notice. See latest updates on our webpage www.helkamabica.com

3 Helkama is specializing in development and production of marine and offshore cables. Our experience in this field goes back more than fifty years. Our high technical quality has been achieved by continuous development work supported by our clients. In this catalogue we proudly present our most comprehensive range of marine cables. We have chosen to produce only halogen-free cables. They remarkably improve the fire safety of the ships by not emitting toxic burning fumes or thick smoke. In addition no corrosive gases damaging the ship and its equipment are emitted in case of a fire. Using the latest technology we have been able to reduce cable weight and size to a minimum and still maintain

quality as well as enabling easy and fast installation. The halogen free range of cables includes both flame-retardant (IEC 60332-3) and fire resistant (IEC 60331-series) cables. Helkama marine cables are approved by all major classification societies. As a specialized and independent company, focusing on service, we have been able to grow steadily by quickly responding to our customers’ needs. Our short delivery times, backed up by extensive stocks, enable us to deliver punctually and keep our clients satisfied. This remains our goal for the future, too.

Type Approval Certificates for factories in Finland and China

Please check updated approval situation on www.helkamabica.com

www.helkamabica.com

HELKAMA — a true specialist in marine cables

0,6/1kV CABLES

4

LKM-HF

Unarmoured power and control cable 0,6/1kV

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor 1,0-10mm2 IEC 60228, class 2 - stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request Flameretardant 2. Insulation Fire- XLPE plastic IEC 60092-360 resistant

4/2015

3. Bedding - separator tape 4. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

5

Part number Normal G-type – 28396 27000 27002 27004 27006 27009 27011 27013 27015 27017 27019 27021 27023 27025 27027 27029 – – – – – – – – – – – – 25672 25689 25704 25706 25708 26072 26074 26076 26078 26080 26082 26085 26086 26088 26090

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex

Nominal outer diameter mm 5,0 5,5 5,5 6,5 7,0 8,0 9,0 11,5 12,5 14,5 17,0 19,5 21,5 24,5 27,0 30,5 33,0 7,5 8,5 9,5 10,5 12,0 14,0 16,5 20,5 23,0 27,5 31,5 8,0 9,0 10,0 11,5 13,0 15,0 17,5 22,0 25,0 29,5 34,5 40,0 44,5 50,5 57,0 64,5

Approximate weight kg/km 35 40 55 70 95 140 185 290 385 540 750 975 1225 1545 1880 2495 3055 65 80 115 155 240 360 490 755 1035 1455 1995 80 100 145 200 310 465 625 970 1325 1880 2615 3455 4365 5485 6800 9045

Current Rating A at +45°C 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355

Min. bending radius fixed installation mm 20 25 25 30 30 35 40 50 50 60 70 80 90 100 165 185 200 30 35 40 45 50 60 70 85 95 170 190 35 40 45 50 55 65 75 90 100 180 210 240 270 305 345 390

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

4/2015

– 25636 25638 25640 25642 25644 25647 25649 25651 25653 25655 25657 25659 25661 25663 25665 26047 25581 25670 25686 25702 25701 25717 26054 26055 26056 26057 26058 25582 25671 25688 25703 25705 25707 26071 26073 26075 26077 26079 26081 26083 26084 26087 26089

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKM-HF 0,6/1kV

4/2015

0,6/1kV CABLES

6

LKM-HF 0,6/1kV Part number Normal G-type 25583 25673 25690 25725 25727 25729 26101 26103 26105 26107 26109 26111 26113 26117 25584 25676 25692 25864 25866 25868 26131 26133 26135 26137 26139 26145 25585 25586 25587 25588 25589 25590 25592 25593 25595

– 25674 25691 25726 25728 25730 26102 26104 26106 26108 26110 26112 26114 26118 – 25677 25693 25865 25867 25869 26132 26134 26136 26138 26140 26146 – – – – – – – – –

Number of conductors & cross-section n x mm2 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x185 Flex 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 5x70 Flex 5x95 Flex 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0

Nominal outer diameter mm 8,5 10,0 11,0 12,5 14,0 16,5 19,5 24,5 27,5 33,0 38,0 44,5 49,5 63,5 9,5 11,0 12,0 13,5 15,5 18,5 21,5 27,5 30,5 37,0 42,5 49,5 10,5 13,5 13,5 14,5 15,5 16,0 19,0 19,5 22,0

Approximate weight kg/km 95 135 180 260 385 585 800 1250 1695 2420 3350 4465 5590 8780 125 160 220 320 475 720 970 1545 2100 2980 4175 5575 155 225 250 280 325 365 465 510 680

Current Rating A at +45°C 13 16 21 28 36 50 66 86 107 137 168 199 232 300 10 13 17 23 30 42 55 71 89 114 139 165 9 8 8 7 7 7 6 6 5

Min. bending radius fixed installation mm 35 40 45 55 60 70 80 100 170 200 230 270 300 385 40 45 50 55 65 75 90 165 185 225 260 300 45 55 55 60 65 65 80 80 90

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

7

Part number Normal G-type 25679 25668 25681 25992 25990 25683 25876 25685 25687 25695 25994 25874 25996 25998 25872 25878 26142

7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5

Nominal outer diameter mm 11,5 15,0 15,5 16,5 17,0 18,5 22,0 22,0 25,0 13,5 17,0 17,5 18,5 19,5 20,5 24,5 25,0

Approximate weight kg/km 200 290 335 380 430 495 635 700 920 285 410 465 535 605 690 900 990

Current Rating A at +45°C 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Min. bending radius fixed installation mm 50 60 65 70 70 75 90 90 100 55 70 70 75 80 85 100 155

4/2015

25678 25667 25680 25991 25989 25682 25875 25684 25675 25694 25993 25696 25995 25997 25873 25877 26141

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKM-HF 0,6/1kV

0,6/1kV CABLES

8

LKMM-HF

Unarmoured power cable with extruded filler 0,6/1kV

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded copper conductor 16–150mm2 IEC 60228, class 5 - tinned stranded copper conductor on request

4/2015

2. Insulation - XLPE plastic

IEC 60092-360

3. Bedding - extruded filler 4. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

9

– – – – – – – – – – 27566 27570 27574 27578 27582 27587 27591 27595 27599 27603 27607 27611 27615 27630 27634 27638 27642 27646 27651 27655 27659 27663 27667 27694 27698 27702 27706 27710 27715 27719

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25

9,0 10,0 11,0 12,5 14,5 18,5 23,0 25,5 30,0 34,0 9,5 10,5 12,0 13,5 15,5 20,0 24,5 27,0 32,0 37,0 42,5 47,0 53,5 10,5 11,5 13,0 14,5 17,5 21,5 27,0 30,0 35,5 40,5 11,5 12,5 14,5 16,5 19,0 24,0 29,5

110 155 205 285 420 630 970 1340 1855 2510 130 180 245 350 515 770 1170 1600 2220 3090 4055 5070 6425 165 215 305 420 635 935 1440 1955 2735 3790 195 255 360 515 770 1145 1750

20 26 34 44 61 80 105 130 167 204 16 21 28 36 50 66 86 107 137 168 199 232 267 16 21 28 36 50 66 86 107 137 168 13 17 23 30 42 55 71

35 40 45 50 60 75 90 155 180 205 35 45 45 55 60 80 100 160 190 220 255 285 320 40 45 50 60 70 85 160 180 210 245 45 50 55 60 75 95 175

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

27532 27534 27536 27538 27540 27543 27545 27547 27549 27551 27564 27568 27572 27576 27580 27585 27589 27593 27597 27601 27605 27609 27613 27628 27632 27636 27640 27644 27649 27653 27657 27661 27665 27692 27696 27700 27704 27708 27713 27717

Nominal outer diameter mm

5/2009

Part number Normal G-type

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKMM-HF 0,6/1kV

0,6/1kV CABLES

10

LKSM-HF

Armoured power and control cable 0,6/1kV

4/2015

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor 1,0-10mm2   IEC 60228, class 2 - stranded copper conductor 16-300mm2  IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - filler tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

11

Part number Normal G-type

Number of conductors & cross-section n x mm2

– – – 27052 27054 27056

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10

26237 26238 26239 26240 26241 26242 26243 26244 26245 26246 26247

27059 27061 27063 27065 27067 27069 27071 27073 27075 27077 27079

1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex

25956 25770 25785 25801 25803 25805

– – – – – –

2x1,0 2x1,5 2x2,5 2x4 2x6 2x10

26253 26254 26255 26256 26257 26258

– – – – – –

26259 25957

25772 25786 25802 25804 25806 26271 26273 26275 26277 26279 26281 26283 26285 26287 26295

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

3,0 3,0 3,1 3,1 3,1 3,5

6,0 6,5 7,0 7,5 8,0 9,5

70 75 90 105 130 190

18 23 30 40 52 72

40 40 45 45 50 60

4,1 4,9 5,5 8,7 11,4 11,5 14,5 14,7 15,2 18,2 18,7

10,5 13,0 14,0 17,0 19,0 21,5 23,5 26,5 29,0 32,5 35,5

240 360 460 650 885 1115 1405 1720 2065 2715 3300

94 123 153 196 240 284 331 381 429 507 582

65 80 90 105 115 130 145 160 180 200 215

3,6 3,8 4,3 4,9 5,4 8,7

9,0 9,5 10,5 12,0 13,0 15,5

110 130 160 210 315 480

15 20 26 34 44 61

55 60 65 75 80 95

2x10 Flex 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex

8,7 10,0 14,5 14,7 18,1 18,7

16,0 18,0 23,0 25,5 29,5 34,0

460 625 985 1240 1700 2270

60 80 105 130 167 204

95 110 140 155 180 205

– –

2x95 Flex 3x1,0

22,2 3,7

39,0 9,5

2965 130

241 13

235 60

25773 25787 25880 25882 25884 26272 26274 26276 26278 26280 26282 26284 26286 26288 26296

3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex

4,1 4,6 5,2 5,8 9,3 10,7 14,6 15,0 18,3 22,0 22,8 37,8 39,3 47,9 50,7

10,0 11,0 12,5 14,0 16,5 19,0 24,5 27,0 32,0 36,5 42,0 47,0 53,0 59,5 67,0

155 195 260 370 570 750 1165 1505 2100 2850 3685 4745 5885 7265 9510

16 21 28 36 50 66 86 107 137 168 199 232 267 300 355

65 70 80 85 100 115 150 165 195 220 255 285 320 360 405

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

4/2015

25955 25736 25738 25740 25742 25744

Crosssection of armour mm2

0,6/1kV CABLES

LKSM-HF 0,6/1kV

4/2015

0,6/1kV CABLES

12

LKSM-HF 0,6/1kV Part number Normal G-type

Number of conductors & cross-section n x mm2

Crosssection of armour mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

25958 25774 25788 25830 25832 25834

– 25775 25789 25831 25833 25835

4x1,0 4x1,5 4x2,5 4x4 4x6 4x10

4,1 4,5 5,0 5,8 8,8 10,3

10,0 11,0 12,5 13,5 15,5 18,0

150 180 240 320 475 695

13 16 21 28 36 50

65 70 75 85 95 110

26299 26301 26303 26305 26307 26309 26311 26313 – 26317

26300 26302 26304 26306 26308 26310 26312 26314 – –

4x10 Flex 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 4x185 Flex

10,3 11,9 14,8 18,1 19,5 22,6 37,8 39,3 48,2 48,9

18,5 21,0 27,0 29,5 35,5 40,0 47,0 52,0 59,0 66,0

655 945 1440 1900 2635 3590 4850 6010 7565 9240

50 66 86 107 137 168 199 232 267 300

115 130 165 180 215 245 285 315 355 400

25959 25776 25790 26011 26013 26015

– 25777 25791 26012 26014 26016

5x1,0 5x1,5 5x2,5 5x4 5x6 5x10

4,5 5,0 5,6 8,6 9,7 11,5

10,5 12,0 13,5 15,0 17,0 20,0

175 220 285 410 565 830

10 13 17 23 30 42

65 75 80 95 105 120

26331 26333 26335 26325 26327 26329

26332 26334 26336 26326 26328 26330

5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 5x70 Flex 5x95 Flex

13,2 18,1 18,6 22,4 34,4 39,3

23,0 29,5 33,0 39,0 45,0 52,0

1070 1655 2295 3215 4560 6045

55 71 89 114 139 165

140 180 200 235 270 315

25960 25961 25962 25963 25964 25965 25977 25978 25981

– – – – – – – – –

7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0

4,9 8,7 9,0 9,4 11,4 11,4 12,5 12,8 14,4

11,5 15,0 15,0 16,0 17,0 17,5 20,5 21,0 23,5

215 320 350 385 445 490 610 655 840

9 8 8 7 7 7 6 6 5

75 90 95 100 105 110 125 130 145

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

13

Part number Normal G-type 25779 26026 25846 26028 26029 25781 25829 25847 25848 25793 26034 25795 26036 26038 25797 25799 25769 25850

Crosssection of armour mm2

7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5

5,4 9,6 9,9 10,5 11,5 11,7 13,9 14,1 16,0 8,5 11,5 11,5 11,8 12,5 13,2 15,7 16,1 18,1

Nominal outer diameter mm 13,0 16,5 17,0 18,0 19,0 19,5 23,5 24,0 26,5 15,0 18,5 19,0 20,5 21,5 22,5 26,0 27,0 30,0

Approximate weight kg/km 265 390 440 490 545 610 780 845 1085 380 535 595 680 760 855 1080 1175 1524

Current Rating A at +45°C 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 9

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Min. bending radius fixed installation mm 80 100 105 110 115 120 140 145 160 90 115 115 125 130 135 160 165 185

4/2015

25778 26025 25780 26027 26030 25782 25828 25783 25784 25792 26033 25794 26035 26037 25796 25798 25768 25849

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKSM-HF 0,6/1kV

0,6/1kV CABLES

14

LKMSM-HF

4/2015

DESIGN:

Armoured power cable with extruded filler 0,6/1kV

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded copper conductor 16–150mm2 IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - extruded filler 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid and galvanized steel wire braid on request 5. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

15

Part number Normal G-type – – – – – – – – – 27266 27270 27274 27278 27282 27287 27291 27295 27299 27303 27307 27311 27315 27330 27334 27338 27342 27346 27351 27355 27359 27363 27367 27371 27375 27394 27398 27402 27406 27410 27415 27419

2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25

Crosssection of armour mm2 4,9 5,4 6,0 9,1 10,7 12,4 15,4 17,1 20,2 5,1 5,7 6,4 9,7 11,4 13,2 16,4 18,2 21,9 25,4 40,6 44,8 51,7 5,6 6,3 9,5 10,6 12,5 14,5 18,2 20,2 24,1 45,7 45,0 51,2 6,1 9,2 10,4 11,8 13,8 16,0 20,1

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

11,5 12,5 14,0 15,5 17,5 20,0 24,5 27,0 31,0 12,0 13,5 14,5 16,0 18,5 21,0 26,0 28,5 33,5 38,5 45,0 49,0 55,5 13,0 14,0 16,0 17,5 20,0 23,0 28,5 31,5 37,0 43,0 49,0 55,0 14,0 15,5 17,0 19,0 22,0 25,5 31,0

195 230 290 425 580 740 1085 1400 1895 220 275 345 495 685 885 1320 1710 2345 3200 4270 5235 6610 260 320 430 590 830 1085 1605 2105 2875 4120 5245 6575 300 395 510 690 985 1300 1925

20 26 34 44 61 80 105 130 167 16 21 28 36 50 66 86 107 137 168 199 232 267 16 21 28 36 50 66 86 107 137 168 199 232 13 17 23 30 42 55 71

70 75 85 90 105 120 145 160 190 75 80 85 95 110 125 155 170 200 230 270 295 335 80 85 95 105 120 140 170 190 220 260 295 330 85 95 105 115 130 152 185

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

27232 27234 27236 27238 27240 27243 27245 27247 27249 27264 27268 27272 27276 27280 27285 27289 27293 27297 27301 27305 27309 27313 27328 27332 27336 27340 27344 27349 27353 27357 27361 27365 27369 27373 27392 27396 27400 27404 27408 27413 27417

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKMSM-HF 0,6/1kV

0,6/1kV CABLES

16

LKAM-HF

Screened power and control cable 0,6/1kV

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request

4/2015

2. Insulation - XLPE plastic

IEC 60092-360

3. Screen - drain wire of tinned copper 1,0mm2 (in all sizes) - aluminium polyester tape, IEC 60092-350 coverage 100% 4. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

17 Part number Normal G-type – 27107 27111 27115 27119 27141 27123 27145 27149 27127 27131 27135 27156 27137 – 27109 27113 27117 27121 27143 27125 27147 27151 27129 27133 27139 27158 27153

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 32x1,5 37x1,5 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 32x2,5 37x2,5

9,0 9,5 10,0 11,0 12,0 15,5 16,0 16,5 17,5 18,5 22,0 22,5 23,5 25,0 9,5 10,5 11,0 12,5 13,5 17,5 18,0 18,5 19,5 21,0 25,0 25,5 26,5 28,5

100 125 150 175 220 310 350 395 450 510 650 710 825 935 130 160 195 240 300 430 495 565 635 740 930 1025 1195 1355

20 16 16 13 12 11 10 10 9 9 8 8 7 7 26 21 21 17 16 14 13 13 12 11 10 10 9 9

55 55 60 65 70 90 95 100 105 110 130 135 140 150 60 60 65 75 80 105 105 110 120 125 150 150 160 170

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

27102 27106 27110 27114 27118 27140 27122 27144 27148 27126 27130 27134 27155 27136 27104 27108 27112 27116 27120 27142 27124 27146 27150 27128 27132 27138 27157 27152

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKAM-HF 0,6/1kV

0,6/1kV CABLES

18

LKEM-HF

DESIGN:

4/2015

1. Conductor - stranded flexible copper conductor

Switchboard wire 0,6/1kV

STANDARDS: IEC 60092-353, design IEC 60228, class 5

2. Insulation - HF90 plastic IEC 60092-360 - standard colour black, other colours on request - on request, oil resistant thermosetting polyolefine, SHF2

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed wiring in switchboards, control panels and other enclosures. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

-test for single insulated wire and cable

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Cable type, cable size, voltage and manufacturer's name

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

19 Part number 25117* 25120 25121 25122 25124 25125 25126 25128 25130 25132 25134 25136 25138 25165 25166 25279 25281 25283 25285

* Rated voltage 300/500V

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

1x0,5 1x0,75 1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

2,3 2,7 2,8 3,1 3,6 4,1 4,7 5,7 6,7 8,6 9,7 11,9 13,7 16,2 18,2 20,8 23,3 26,8 28,9

10 14 17 21 32 45 63 103 154 244 334 476 671 887 1125 1424 1753 2357 2900

11 14 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582

10 15 15 15 15 20 20 25 30 35 40 50 55 65 75 85 95 110 120

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Available in colours: blue, dark blue, black, brown, red, yellow, green, yellow/green, grey, orange, violet and white Other colours on request   Delivery lengths: 0,5 mm2, 0,75 mm2, 1 mm2, 1,5 mm2 and 2,5 mm2 available in 200 m boxes or 500 m drums 4 mm2 available in 100 m boxes or 500 m drums 6 mm2 available in 100 m coils or 500 m drums

4/2015

Other sizes on request.

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKEM-HF 0,6/1kV

EMC CABLES

20

LKSM-EMC

Armoured power and control cable with improved EMC screening 0,6/1kV

4/2015

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor 2 -stranded copper conductor 1,0-10mm 2 IEC 60228, class 2 -stranded copper conductor 16-300mm IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - filler tape 4. Screen - copper tape, coverage 100% 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Transfer impedance

IEC 61196-1

(typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m])

For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification:

See technical information section.

Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

21

Part number Normal G-type

Crosssection of armour mm2

Diameter of screen mm

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95

3,0 3,0 3,0 3,1 3,1 3,3 4,2 4,9 5,6 8,8 10,0 11,5 12,4 14,7 15,3 17,1 18,8 3,3 3,6 4,1 4,6 5,1 8,5 11,4 12,4 14,7 16,4 18,8 21,3

4,0 4,0 4,5 5,0 6,0 7,0 8,5 10,5 11,5 14,0 16,0 18,5 20,0 23,0 25,5 29,0 31,0 6,5 7,0 8,0 9,0 10,5 12,5 15,5 19,5 21,5 26,0 29,5 34,5

6,0 6,5 7,0 7,5 8,0 9,5 11,0 13,5 14,5 17,0 19,0 21,5 24,0 26,5 29,5 33,0 35,5 9,5 10,0 11,0 12,0 13,0 16,0 18,5 23,0 25,5 30,0 34,0 39,0

90 100 110 130 155 230 280 405 515 705 940 1185 1465 1815 2165 2795 3425 130 145 180 250 340 535 725 1045 1325 1785 2385 3100

18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Min. bending radius fixed installation mm 37 39 41 45 48 57 66 80 86 102 114 129 143 160 176 197 213 56 59 65 72 79 95 112 138 153 179 204 235

Table continues on next page

4/2015

26904 27513 27514 27515 27516 27517 27518 27519 27520 27521 27522 27523 27524 27525 27526 27527 27528 26905 27480 27481 27482 27483 27484 27485 27486 27487 27529 27530 27531

Number of conductors & cross-section n x mm2

EMC CABLES

LKSM-EMC 0,6/1kV

EMC CABLES

22

LKSM-EMC 0,6/1kV

4/2015

Part number Normal G-type 26906 26861 26863 26865 26867 26869 26872 26874 26876 26878 26880 26882 26884 26886 26907 26942 26944 26946 26948 26950 26952 26954 26956 26958 26960 26962 26964 26966 26908 27488 27489 27490 27491 27492 27493 27494

26988 26862 26864 26866 26868 26870 26851 26852 26853 26854 26855 26856 26857 26858 26989 26943 26945 26947 26949 26951 26953 26955 26957 26959 26961 26963 26965 26967 26990 27838 27839 27940 27941 27942 27943 27944

Number of conductors & cross-section n x mm2 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25

Crosssection of armour mm2 3,6 3,9 4,3 5,0 5,6 8,9 10,9 14,6 15,2 18,3 22,0 22,9 37,9 39,4 3,9 4,3 4,9 5,5 8,5 9,9 12,0 14,8 18,2 19,6 22,6 37,9 39,4 43,7 4,2 4,7 5,3 11,3 11,4 11,0 13,3 16,4

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Diameter of screen mm

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

7,0 7,5 8,5 10,0 11,0 13,5 16,5 21,0 23,0 27,5 32,0 37,0 41,5 47,5 8,0 8,5 9,5 11,0 12,5 15,0 18,0 23,0 25,5 31,0 35,5 42,0 46,5 52,5 8,5 9,5 10,5 12,5 14,0 16,5 20,0 25,5

10,0 10,5 11,5 12,5 14,0 16,5 19,5 24,5 27,0 32,0 36,5 42,0 47,0 53,0 10,5 11,0 12,5 13,5 15,5 18,5 22,0 27,0 30,0 35,5 40,0 47,5 52,5 59,0 11,0 12,0 13,5 15,5 17,0 20,0 23,5 29,5

155 175 215 285 395 630 835 1245 1590 2205 2970 3825 4895 6060 175 200 260 340 505 750 1020 1510 1970 2715 3675 4935 6095 7610 200 240 305 460 615 875 1220 1775

13 16 21 28 36 50 66 86 107 137 168 199 232 267 13 16 21 28 36 50 66 86 107 137 168 199 232 267 10 13 17 23 30 42 55 71

Min. bending radius fixed installation mm 59 62 68 76 84 100 118 147 162 193 219 252 283 319 63 67 74 82 94 110 131 161 179 213 241 284 314 355 67 73 80 92 102 120 142 177

Table continues on next page

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

23

Part number Normal G-type 26991 26992 26993 26994 26995 26996 26997 26998 26999 27840 27842 27844 27846 27848 27850 27852 27854 27856 27841 27843 27845 27847 27849 27851 27853 27855

7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5

CrossDiameter section of o f screen armour mm mm2 4,7 9,5 9,9 12,5 9,9 13,0 9,9 13,5 10,0 14,5 10,2 15,0 12,2 18,0 12,5 18,5 14,1 20,5 5,2 10,0 9,2 13,5 10,0 14,0 10,2 15,0 10,8 15,5 11,4 16,5 13,6 19,5 13,9 20,0 15,7 22,5 5,8 11,5 11,4 15,5 11,5 16,0 11,5 17,0 12,2 18,0 12,9 19,0 15,3 22,5 15,8 23,0

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Nominal outer diameter mm

Approximate weight kg/km

12,5 15,5 16,0 16,5 17,5 18,5 21,5 22,0 24,5 13,0 16,5 17,0 18,0 19,0 20,0 23,0 24,0 26,5 14,5 18,5 19,0 20,0 21,5 22,5 26,0 27,0

240 365 395 430 465 550 695 750 935 285 420 465 520 570 675 855 930 1175 365 555 620 690 775 910 1145 1250

Current Rating A at +45°C 9 8 8 7 7 7 6 6 5 23 20 16 16 13 23 20 16 23 30 26 21 21 17 30 26 21

Min. bending radius fixed installation mm 74 93 96 100 105 111 130 132 147 78 99 102 108 113 119 139 143 160 87 111 115 120 128 135 157 161

4/2015

26909 26910 26911 26912 26913 26914 26915 26916 26917 27495 27497 27499 27501 27503 27505 27507 27509 27511 27496 27498 27500 27502 27504 27506 27508 27510

Number of conductors & cross-section n x mm2

EMC CABLES

LKSM-EMC 0,6/1kV

EMC CABLES

24

LKSM-EMC-FRHF

4/2015

DESIGN:

Fire-resistant armoured power and control cable with improved EMC screening 0,6/1kV

STANDARDS: IEC 60092-353, design

1. Conductor 2 -stranded copper conductor 1,0-10mm 2 IEC 60228, class 2 Flame-stranded copper conductor 16-300mm IEC 60228, class 5 retardant - tinned stranded copper conductor on request Fire2. Insulation resistant - Mica tape Halogen- XLPE plastic IEC 60092-360 free 3. Bedding Low smoke - filler tape emission 4. Screen Oil resistant - copper tape, coverage 100% (only SHF2) 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1, standard colour orange IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer shetah is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant Fire -resistant Halogen-free Smoke emission Oil resistance (only SHF2)

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60331-1 and IEC 60331-2 IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2

Transfer impedance

IEC 61196-1

(typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m])

For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification:

See technical information section.

Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

25

– 27872 27873 27874 27875 27876 27877 27878 27879 27880 27881 –

2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95

3,3 4,1 4,6 5,1 5,6 9,0 11,4 12,7 14,8 16,7 19,1 21,5

9,5 10,5 11,5 13,0 14,0 16,5 19,0 23,5 26,0 30,0 34,5 40,0

135 165 190 270 390 570 745 1075 1355 1830 2435 3170

15 20 26 34 44 61 80 105 130 167 204 241

55 65 70 80 85 100 115 140 155 180 205 240

– 27882 27883 27884 27885 27886 27887 27888 27889 27890 27891 27892 27893 27894

3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150

3,6 4,4 4,9 5,5 11,3 9,7 11,6 14,7 15,9 18,5 22,2 43,2 38,3 40,2

10,0 11,5 12,5 13,5 15,5 17,5 20,5 25,5 28,0 33,0 37,5 44,0 48,0 54,5

155 210 260 325 505 665 900 1335 1695 2285 3060 4160 5010 6210

13 16 21 28 36 50 66 86 107 137 168 199 232 267

60 70 75 80 90 105 125 155 170 200 225 265 290 325

– 27897 27898 27899 27900 27905 27906 27907 27908 27909 27910 27912 27913 –

4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150

3,9 4,9 5,5 11,3 9,3 10,8 12,9 15,6 18,3 20,4 23,4 38,3 40,4 45,0

10,5 12,5 13,5 15,5 16,5 19,5 23,0 28,0 31,0 36,5 41,5 48,5 53,5 60,5

190 250 305 445 570 805 1105 1620 2105 2840 3830 5060 6260 7790

13 16 21 28 36 50 66 86 107 137 168 199 232 267

65 75 80 90 100 115 140 170 185 220 250 290 320 365

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

6,0 7,0 7,5 8,0 8,5 10,0 11,0 13,0 14,5 17,0 19,0 21,5 23,5 26,5 29,0 32,5 35,5

105 115 125 145 170 230 285 410 515 705 945 1195 1475 1820 2175 2800 3430

18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582

35 40 45 45 50 60 65 80 85 100 115 130 140 160 175 195 210

Table continues on next page

4/2015

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300

Part number

Number of conductors & cross-section n x mm2

EMC CABLES

– – – – – – – – – – – – – – – – –

Crosssection of armour mm2 3,0 3,0 3,1 3,1 3,1 3,5 4,1 4,9 5,5 8,7 9,9 11,5 12,3 14,7 15,2 17,0 18,7

LKSM-EMC-FRHF 0,6/1kV

EMC CABLES

26

– 27914 27915 27916 27917 27918 27919 27920

5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25

Crosssection of armour mm2 4,3 5,4 11,3 11,4 11,4 11,9 14,1 17,3

– – – – – – – – – –

7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 30x1,0 37x1,0

5,2 8,5 9,9 9,9 10,0 11,4 12,4 12,7 13,2 14,4

12,5 15,5 16,0 17,0 17,5 18,5 21,5 22,0 23,0 24,5

250 360 405 440 480 550 690 735 795 930

9 8 8 7 7 7 6 6 6 5

75 95 95 100 105 110 130 135 135 150

27921 27923 27925 27927 27929 27931 27933 27935 – 27937

7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 30x1,5 37x1,5

14,1 10,6 11,0 11,7 12,4 13,1 15,6 15,9 16,5 18,0

15,0 18,5 19,0 20,0 21,5 22,5 26,0 27,0 27,5 30,0

400 485 535 590 675 750 945 1030 1110 1315

12 11 10 10 9 9 8 8 7 7

90 110 115 120 130 135 155 160 165 180

27922 27924 27926 27928 27930 27932 27934 27936 – 27938

7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 37x2,5

11,3 11,8 12,3 13,0 13,8 14,6 17,5 17,9 18,6 20,2

16,0 21,0 21,5 22,5 23,5 25,0 29,0 30,0 31,0 33,5

460 630 705 785 875 985 1245 1375 1490 1770

16 14 13 12 12 11 10 10 10 9

95 125 130 135 140 150 175 180 185 200

LKSM-EMC-FRHF 0,6/1kV

4/2015

Part number

Number of conductors & cross-section n x mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

11,5 13,5 15,0 16,5 18,5 21,5 25,0 30,5

220 290 415 525 685 975 1320 1880

10 13 17 23 30 42 55 71

70 80 90 100 110 130 150 185

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

27 EMC CABLES 4/2015

EMC CABLES

28

RFE-EMC

Armoured pair instrumentation and communication cable with improved EMC screening 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Screen - drain wire copper (in all sizes) - copper tape 100% 6. Armour - copper wire braid, coverage >94% EC 60092-350 - tinned copper wire braid on request 7. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) Transfer impedance

150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m])

Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 60 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

29

Part number

1x2x0,5 2x2x0,5 Quad 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 Quad 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 27x2x0,75 30x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

7,0 7,5 9,5 10,0 11,0 13,0 13,5 15,5 16,0 17,5 18,0 19,5 21,5 22,5 23,5 24,5 26,0 8,0 9,0 11,0 11,5 13,0 15,5 16,5 18,5 19,0 20,5 22,0 23,5 26,0 27,0 28,5 29,5 31,0 10,0 11,5 14,5 15,0 17,0 20,5 22,0 24,5 26,0 27,5 29,5 31,5 35,5 37,0 39,0 40,0 43,5

95 115 150 165 185 270 290 365 395 445 480 540 655 710 775 810 900 110 150 175 200 255 365 400 475 520 600 655 755 900 980 1060 1140 1270 165 220 285 335 425 605 690 820 935 1045 1175 1335 1650 1810 1985 2090 2490

40 45 60 60 65 75 80 95 95 105 110 115 130 135 140 145 155 45 55 65 70 75 95 100 110 115 125 130 140 155 165 170 175 185 60 70 85 90 100 120 130 150 155 165 175 190 210 220 235 240 260

4/2015

21968 21970 21971 21972 21973 21974 21975 21976 21977 21978 21979 21980 21981 21982 21983 21984 21985 21987 21989 21990 21991 21992 21993 21994 21995 21996 21997 21998 21999 22000 22001 22002 22003 22004 22375 22377 22378 22379 22380 22381 22382 22383 22384 22385 22386 22387 22388 22389 22390 22391 22392

Number of conductors & cross-section n x mm2

EMC CABLES

RFE-EMC 250V

EMC CABLES

30

RFE-EMC(i)

4/2015

DESIGN:

Armoured and pair screened instrumentation and communication cable with improved EMC screening 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & pair screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - filler tape 5. Screen - drain wire copper (in all sizes) - copper tape 100% 6. Armour - copper wire braid, coverage >94% IEC 60092-350 - tinned copper wire braid on request 7. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Design to meet requirements for improved EMC screening properties. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) Transfer impedance

150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m])

Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 90 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

31

Part number

Number of conductors & cross-section n x mm2

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

1x2x0,5 2x2x0,5 Quad 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5

7,0 7,5 10,0 10,0 11,0 13,0 14,0 16,0 16,5 17,5 18,5 20,0 22,0 23,0 24,0 25,0 26,5

90 120 150 175 205 300 360 430 490 540 590 690 835 910 990 1050 1180

40 45 60 60 65 80 85 95 100 105 110 120 135 140 145 150 160

21911 21913 21914 21915 21916 21917 21918 21919 21920 21921 21922 21923 21924 21925 21926 21927 21928

1x2x0,75 2x2x0,75 Quad 2x2x0,75 3x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 27x2x0,75 30x2x0,75 32x2x0,75 37x2x0,75

7,5 9,0 11,5 12,0 13,0 15,5 16,5 19,0 20,0 21,0 22,5 24,0 26,5 28,0 29,0 30,0 32,0

105 150 185 215 255 390 435 530 590 660 740 840 1040 1135 1230 1310 1465

45 55 70 70 75 95 100 115 120 125 135 145 160 165 175 180 190

21930 21932 21933 21934 21935 21936 21937 21938 21939 21940 21941 21942 21943 21944 21945 21946 21947

1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5

10,0 11,5 14,5 16,0 17,0 20,5 22,0 25,0 26,0 28,0 29,5 32,0 36,0 37,5 40,0 41,0 44,0

160 220 280 370 440 645 730 890 1005 1150 1275 1490 1835 2015 2235 2450 2780

60 70 85 95 105 125 135 150 155 170 180 195 215 225 240 245 265

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

21949 21951 21952 21953 21954 21955 21956 21957 21958 21959 21960 21961 21962 21963 21964 21965 21966

EMC CABLES

RFE-EMC(i) 250V

1,8/3kV CABLES

32

LKSM-VFD

Armoured power and control cable with improved EMC screening 1,8/3kV

4/2015

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor IEC 60228, class 5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - filler tape 4. Screen - copper tape, coverage 100% 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. Design to meet requirements for Variable Frequency Drivers (VFD). Suitable for voltage peaks up to 3kV. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant

1,8/3kV (3,6kV)

Halogen-free Smoke emission

+ 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Transfer impedance

IEC 61196-1

(typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m])

For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification:

See technical information section. Cable with yellow/green protective earth (PE) conductor on request

Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

33

Part number

1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x95+3x16 3x120+3x25 3x150+3x25

4,7 5,5 8,5 9,3 10,3 11,3 12,5 13,6 14,7 15,8 17,6 18,9 13,2 16,4 16,9 18,7 28,8 32,0 35,4 38,6 42,0 45,5 35,4 38,6 42,0

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx NOTE! 1) = Protective earth (PE) rules are not fulfilled. (PE rules, for cables over 16mm2 the PEconductor have to be half of main conductor and min. 16mm2. This according to IEC 60092-352, Electrical installations in ships –Choice and installation of electrical cables) 2 = Three additional protective earth (PE) conductors. Protective earth (PE) rules are fulfilled.

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

12,5 14,0 16,0 17,0 19,0 20,5 23,5 25,5 27,5 29,5 33,0 35,0 23,5 26,5 29,5 32,5 37,0 41,0 46,5 50,5 55,0 60,0 46,5 50,5 55,0

280 355 495 625 795 995 1280 1525 1830 2165 2800 3365 890 1160 1525 1910 2580 3395 4295 5200 6255 7475 4655 5755 6780

71 94 123 153 196 240 284 331 381 429 507 582 50 66 86 107 137 168 199 232 267 300 199 232 267

75 85 95 105 115 125 140 150 165 180 200 210 140 160 180 195 225 245 280 305 330 360 280 305 330

Note

1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1)

1) 1) 1) 1) 2) 2) 2)

4/2015

26918 26920 26922 26924 26926 26928 26930 26932 26934 26936 26938 26940 26892 26871 26873 26875 26877 26879 26881 26883 26885 26887 26893 26895 26897

Number of Crossconductors & section of cross-section armour n x mm2 mm2

1,8/3kV CABLES

LKSM-VFD 1,8/3kV

0,6/1kV CABLES

34

LKM-FRHF DESIGN:

Fire-resistant unarmoured power and control cable 0,6/1kV

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor IEC 60228, class 2 (class 5 on request) - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic

IEC 60092-360

4/2015

3. Bedding - separator tape

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant

4. Sheath (only SHF2) - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

35

Part number Normal G-type – – – – – – – – – – – – – – – – – – – – – – – – – – – – 28279 28163 28165 28167 28169 28171 29367 29369 29371 29373 29375 29377 29379

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex

5,5 5,5 6,0 6,5 7,5 8,5 9,5 12,0 13,0 15,0 17,5 20,0 22,0 25,0 27,5 31,0 33,5 8,5 9,0 10,5 11,5 13,0 15,0 17,5 21,5 24,0 28,5 32,5 38,0 9,0 9,5 11,0 12,5 14,0 16,0 18,5 23,0 26,0 30,5 35,0 41,0 45,5

40 45 60 80 100 150 200 310 405 560 775 1000 1255 1580 1920 2540 3105 75 90 125 165 260 385 530 805 1095 1525 2075 2775 95 115 160 220 330 485 675 1030 1400 1970 2720 3570 4500

18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 13 16 21 28 36 50 66 86 107 137 168 199 232

30 35 35 40 45 50 40 50 55 65 70 80 90 100 170 190 205 50 55 65 70 75 90 70 90 100 175 200 230 55 60 65 75 85 95 75 95 155 185 215 245 275

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

4/2015

28275 28100 28102 28104 28106 28108 29326 29327 29328 29329 29330 29331 29332 29333 29334 29335 29336 28276 28132 28134 28136 28138 28140 29343 29344 29345 29346 29347 29348 28278 28162 28164 28166 28168 28170 29366 29368 29370 29372 29374 29376 29378

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKM-FRHF 0,6/1kV

4/2015

0,6/1kV CABLES

36 LKM-FRHF 0,6/1kV Part number Normal G-type 28280 28182 28184 28186 28188 28190 29400 29402 29404 29406 29408 29410 28282 28212 28214 28501 28503 28505 29434 29436 29438 29440

28281 28183 28185 28187 28189 28191 29401 29403 29405 29407 29409 29411 28283 28213 28215 28502 28504 28506 29435 29437 29439 29441

Number of conductors & cross-section n x mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex

9,5 11,0 12,0 13,5 15,0 18,0 20,5 26,0 28,5 34,5 39,0 46,0 11,0 12,0 13,0 15,0 16,5 19,5 22,5 28,5 31,5 38,0

115 150 200 280 405 610 865 1330 1790 2530 3475 4615 150 185 240 345 505 750 1050 1640 2215 3120

13 16 21 28 36 50 66 86 107 137 168 199 10 13 17 23 30 42 55 71 89 114

60 65 75 80 90 105 85 155 175 210 235 275 65 70 80 90 100 115 95 175 195 230

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

37 Part number Normal G-type 28285 28287 28289 28291 28293 28295 28297 28299 28301 28217 28241 28221 28245 28249 28225 28229 28233 28235 28219 28243 28223 28247 28251 28227 28231 28237 28239

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

12,0 15,0 15,5 16,5 17,5 18,5 21,5 22,0 25,0 13,0 16,5 17,5 18,5 19,5 20,5 24,5 25,0 28,0 14,5 18,5 19,5 20,5 21,5 23,0 27,5 28,0 31,5

180 260 295 330 380 435 550 600 805 230 330 380 430 485 565 725 795 1050 315 450 510 590 670 765 995 1095 1450

9 8 8 7 7 7 6 6 5 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 9

70 90 95 100 105 110 130 130 150 80 100 105 110 115 125 145 150 170 90 110 115 125 130 135 165 170 190

7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

28284 28286 28288 28290 28292 28294 28296 28298 28300 28216 28240 28220 28244 28248 28224 28228 28232 28234 28218 28242 28222 28246 28250 28226 28230 28236 28238

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKM-FRHF 0,6/1kV

0,6/1kV CABLES

38

LKSM-FRHF DESIGN:

Fire-resistant armoured power and control cable 0,6/1kV

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor IEC 60228, class 2 (class 5 on request) - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic

EC 60092-360

4/2015

3. Bedding - separator tape 4. Armour - copper wire braid, coverage > 90% - tinned copper wire braid on request

IEC 60092-350

5. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

39

Part number Normal G-type – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 28544 28623 28625 28627 28629 28631 29083 29085 29087 29089 29091 29093 29095 29097 29099 29101

Crosssection of armour mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1,0 2x1,5 2x2,5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3x1,0 3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex

3,0 3,0 3,1 3,1 3,1 3,5 4,1 5,2 5,5 8,7 11,4 11,5 12,3 14,7 15,2 18,2 18,7 3,5 3,8 4,3 4,9 5,4 8,7 10,0 14,5 14,7 18,1 18,7 22,2 4,1 4,1 4,6 5,2 5,8 9,3 10,7 14,6 15,0 17,5 22,0 22,8 37,8 39,3 47,9 50,7

6,5 7,0 7,0 8,0 8,5 10,0 11,0 13,5 14,5 17,5 19,5 22,0 24,0 27,0 29,5 33,0 36,0 10,0 10,5 11,5 13,0 14,0 16,5 19,0 24,0 26,0 30,5 35,0 40,0 10,5 11,0 12,0 13,5 15,0 17,5 20,0 25,5 28,0 33,0 37,5 43,0 48,0 54,0 60,5 68,0

75 80 95 115 140 195 255 380 475 665 905 1135 1410 1745 2090 2735 3325 120 140 170 225 340 505 665 1035 1300 1765 2345 3045 145 170 210 280 400 595 800 1225 1570 2170 2935 3775 4840 5990 7375 9625

18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355

40 40 45 45 50 60 70 85 90 105 120 135 150 165 180 200 215 60 65 70 75 85 100 115 145 160 185 210 245 60 65 75 80 90 105 125 155 170 200 225 260 290 325 365 410

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Table continues on next page

4/2015

28541 28568 28570 28572 28574 28576 29060 29061 29062 29063 29064 29065 29066 29067 29068 29069 29070 28542 28602 28604 28606 28608 28610 29071 29072 29073 29074 29075 29076 28543 28622 28624 28626 28628 28630 29082 29084 29086 29088 29090 29092 29094 29096 29098 29100

Number of conductors & cross-section n x mm2

0,6/1kV CABLES

LKSM-FRHF 0,6/1kV

4/2015

0,6/1kV CABLES

40

LKSM-FRHF 0,6/1kV Part number Normal G-type 28545 28642 28644 28646 28648 28650 29104 29106 29108 29110 29112 29114 28547 28662 28664 28705 28707 28709 29126 29128 29130 29132 28549 28551 28553 28555 28557 28559 28561 28563 28565 28666 28723 28670 28727 28731 28674 28678 28682 28684 28668 28725 28672 28729 28733 28676 28680 28686 28688

28546 28643 28645 28647 28649 28651 29105 29107 29109 29111 29113 29115 28548 28663 28665 28706 28708 28710 29127 29129 29131 29133 28550 28552 28554 28556 28558 28560 28562 28564 28566 28667 28724 28671 28728 28732 28675 28679 28683 28685 28669 28726 28673 28730 28734 28677 28681 28687 28689

Number of conductors & cross-section n x mm2 4x1,0 4x1,5 4x2,5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 5x1,0 5x1,5 5x2,5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5

Crosssection of armour mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

4,1 4,5 5,0 5,7 8,8 10,3 11,9 14,8 18,1 19,5 22,6 35,0 4,5 5,0 5,6 8,6 9,7 11,5 13,2 18,1 18,6 22,4 4,9 8,7 9,0 11,4 11,4 11,4 12,5 12,8 14,4 5,4 9,6 9,9 11,4 11,5 11,7 13,9 14,1 16,0 8,5 11,5 11,5 11,8 12,5 13,2 15,7 16,1 18,1

11,0 12,0 13,5 14,5 16,5 19,5 22,5 28,0 30,5 36,5 41,0 48,5 12,0 13,5 14,5 16,5 18,0 21,0 24,5 30,5 34,0 40,0 13,0 16,5 17,0 18,0 19,0 20,0 23,5 24,0 26,5 14,5 18,0 19,0 20,0 21,0 22,0 26,0 26,5 29,5 16,0 20,0 21,0 22,5 23,5 24,5 29,0 29,5 33,0

170 200 255 335 505 725 1010 1515 1980 2730 3695 4935 195 245 305 440 600 870 1135 1735 2390 3330 240 355 395 455 505 555 695 750 960 295 430 490 555 610 680 875 945 1220 405 570 635 730 815 920 1165 1265 1660

13 16 21 28 36 50 66 86 107 137 168 199 10 13 17 23 30 42 55 71 89 114 9 8 8 7 7 7 6 6 5 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 9

65 70 80 90 100 115 135 170 185 220 250 290 70 80 85 100 110 125 150 185 205 245 80 100 100 105 115 120 140 145 160 85 110 115 120 125 130 155 160 180 95 120 125 135 140 145 175 175 200

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

41 0,6/1kV CABLES 4/2015

0,6/1kV CABLES

42

LKAM-FRHF DESIGN:

Fire-resistant screened power and control cable 0,6/1kV

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic

IEC 60092-360

4/2015

3. Screen - drain wire of tinned copper 1,0mm2 (in all sizes) - aluminium polyester tape, IEC 60092-350 coverage 100%

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

4. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

43

Part number Normal G-type

Number of conductors & cross-section n x mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

– 28744 28748 28752 28756 28760 28764 28768 28772 28776 28780 28784 28788

2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5

9,5 10,5 11,0 12,0 13,5 17,0 17,5 18,5 19,5 20,5 24,5 25,0 28,5

115 140 165 200 250 350 400 450 515 580 740 810 1065

20 16 16 13 12 11 10 10 9 9 8 8 7

60 60 65 75 80 100 105 110 120 125 145 150 170

28742 28745 28749 28753 28757 28761 28765 28769 28773 28777 28781 28785 28789

– 28746 28750 28754 28758 28762 28766 28770 28774 28778 28782 28786 28790

2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 37x2,5

10,5 11,5 12,5 13,5 14,5 19,0 19,5 20,5 22,0 23,5 27,5 28,0 31,5

140 175 215 270 335 480 550 625 700 820 1035 1140 1505

26 21 21 17 16 14 13 13 12 11 10 10 9

65 70 75 80 90 115 120 125 130 140 165 170 190

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

28741 28743 28747 28751 28755 28759 28763 28767 28771 28775 28779 28783 28787

0,6/1kV CABLES

LKAM-FRHF 0,6/1kV

250V CABLES

44

LKM-HF

Unarmoured control and instrumentation cable 250V

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic

IEC 60092-360

4/2015

3. Bedding - separator tape 4. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units.If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

45

Part number

Number of conductors & cross-section n x mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5

5,5 6,0 6,5 7,0 7,5 9,5 10,0 10,0 11,0 11,0 12,0 13,0 13,5 14,0 15,0

35 45 55 65 75 115 125 140 160 180 190 225 245 280 315

8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3

25 25 25 30 30 40 40 40 45 45 45 55 55 55 60

26365 26366 26367 26368 26369 26370 26371 26372 26373 26374 26375 26376 26377 26378 26379

2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

6,5 7,0 7,5 8,0 8,5 11,0 11,5 12,5 13,0 13,5 14,5 16,0 16,0 16,5 18,0

50 60 70 85 105 155 175 200 225 255 275 320 350 400 460

11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

25 25 30 30 35 45 45 50 50 55 55 65 65 65 75

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

27821 27822 27823 27824 27825 27826 27827 27828 27829 27830 27831 27832 27833 27834 27835

250V CABLES

LKM-HF 250V

250V CABLES

46

LKSM-HF

Armoured control and instrumentation cable 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Bedding - separator tape 4. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

47

Part number

2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Crosssection of armour mm2 3,0 3,0 3,1 3,1 3,2 4,1 4,3 4,5 5,3 5,3 5,5 6,1 6,3 8,9 9,7 3,1 3,1 3,2 3,6 3,9 5,3 5,3 5,6 5,9 6,3 10,9 10,2 10,5 10,9 11,8

Nominal outer diameter mm 6,5 7,0 7,5 8,0 8,5 10,5 10,5 11,0 11,5 12,5 13,0 14,0 14,5 15,0 16,0 7,5 7,5 8,0 9,5 10,0 12,0 12,5 13,0 13,5 14,5 18,0 17,0 17,5 18,0 19,5

Approximate weight kg/km 75 80 90 100 115 160 175 195 215 240 260 290 315 380 425 85 95 110 135 155 215 235 260 290 320 440 425 460 520 580

Current Rating A at +45°C

Min. bending radius fixed installation mm

8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

40 40 45 45 50 60 65 65 70 75 80 85 85 90 95 45 45 50 55 60 75 75 80 80 85 105 100 105 110 115

4/2015

27779 27780 27781 27782 27783 27784 27785 27786 27787 27788 27789 27790 27791 27792 27793 26402 26403 26404 26405 26407 26410 26412 26414 26416 26419 26420 26424 26427 26432 26437

Number of conductors & cross-section n x mm2

250V CABLES

LKSM-HF 250V

250V CABLES

48

LKAM-HF

Screened control and instrumentation cable 250V

DESIGN:

STANDARDS: IEC 60092-376, design

4/2015

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic

IEC 60092-360

3. Screen - drain wire of tinned copper - aluminium polyester tape, coverage 100%

IEC 60092-350

4. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

49

Approximate weight kg/km

26440 26441 26442 26443 26444 26445 26446 26447 26448 26449 26450 26451 26452 26453 26454

2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5

6,0 6,5 7,0 7,5 8,0 10,5 10,5 11,0 11,5 12,5 13,0 14,5 14,5 15,5 16,5

45 55 65 75 90 130 145 160 180 200 225 255 275 320 360

8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3

25 25 30 30 30 40 45 45 45 50 55 60 60 60 65

26382 26383 26384 26385 26386 26387 26388 26389 26390 26391 26392 26393 26394 26395 26396

2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

6,5 7,0 7,5 8,0 9,0 11,0 12,0 12,5 13,0 13,5 14,5 16,0 16,0 17,0 18,0

55 65 75 90 115 160 185 205 230 260 285 325 355 415 465

11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

25 30 30 30 35 45 45 50 50 55 60 65 65 70 75

Part number

Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Current Rating A at +45°C

Min. bending radius fixed installation mm

4/2015

Nominal outer diameter mm

250V CABLES

Number of conductors & cross-section n x mm2

LKAM-HF 250V

250V CABLES

50

RFE-HF

Armoured pair instrumentation and communication cable 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant

150/250V (300V)

Halogen-free Smoke emission

+ 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 60 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

51

Part number

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

6,5 7,5 9,5 10,5 12,5 13,5 15,5 16,0 17,0 18,0 19,0 21,5 8,5 11,0 12,5 15,0 16,0 18,0 19,0 20,0 21,5 23,0 25,5 29,0 10,0 10,5 14,5 17,0 20,0 21,5 24,5 26,0 27,5 29,0 31,5 35,0 40,0

75 95 120 155 220 240 315 350 390 435 490 600 115 150 210 290 350 425 475 530 600 680 820 1035 140 185 235 380 555 635 770 865 975 1095 1250 1555 1980

40 45 55 65 75 80 90 95 100 110 115 130 50 65 75 90 95 110 115 120 130 140 155 175 60 65 85 100 120 130 150 155 165 175 190 210 240

1x2x0,5 2x2x0,5 Quad 2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

20362 20364 20363 20366 20368 20369 20370 20371 20372 20373 20374 20376 20384 20383 20386 20388 20389 20390 20391 20392 20393 20394 20396 20398 20490 20491 20492 20493 20494 20495 20496 20497 20498 20503 20499 20500 20501

Number of conductors & cross-section n x mm2

250V CABLES

RFE-HF 250V

250V CABLES

52

RFE-HF (i)

4/2015

DESIGN:

Armoured and pair screened instrumentation and communication cable 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & pair screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - filler tape 5. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant

150/250V (300V)

Halogen-free Smoke emission

+ 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 90 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

53

Part number

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

1x2x0,5 1x3x0,5 1x4x0,5 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 1x4x0,75 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 1x3x1,5 1x4x1,5 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5

7,0 7,0 7,5 9,5 10,0 11,0 13,0 13,5 15,5 16,5 17,5 18,5 19,5 22,0 23,0 24,0 24,5 26,5 7,5 8,5 11,0 13,0 15,5 16,5 18,5 19,5 21,0 23,5 26,0 30,0 10,0 10,5 11,0 14,5 17,0 20,5 22,0 25,0 26,0 28,0 32,0 36,0 41,0

85 100 115 140 165 205 295 325 420 475 540 600 685 855 940 1020 1075 1225 95 125 165 235 365 400 485 550 635 810 980 1255 150 175 205 255 415 615 705 860 975 1110 1450 1785 2395

40 45 45 60 60 65 75 80 95 100 105 110 120 135 140 145 150 160 45 50 65 75 95 100 110 115 125 140 155 180 60 60 65 85 105 120 130 150 155 170 195 215 245

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

22338 22340 22342 22344 22346 22348 22350 22352 22354 22356 22358 22360 22362 22364 22366 22368 22370 22372 22006 22008 22010 22012 22014 22016 22018 22020 22022 22024 22026 22028 22050 22049 22052 22054 22056 22058 22060 22062 22064 22066 22068 22070 22072

Number of conductors & cross-section n x mm2

250V CABLES

RFE-HF(i) 250V

250V CABLES

54

RFA-HF

Screened pair instrumentation and communication cable 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Screen - drain wire tinned copper - aluminium polyester tape IEC 60092-350 coverage 100% 5. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2)

150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2

Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 60 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

55

Part number

Nominal outer diameter mm

1x2x0,5 2x2x0,5 Quad 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 37x2x0,75 1x2x1,5 1x3x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

5,5 6,5 8,0 9,0 9,5 11,5 12,5 14,0 14,5 15,5 16,5 18,0 20,0 23,0 24,5 6,5 7,5 10,0 11,5 14,0 15,0 17,0 17,5 19,0 20,5 22,0 24,0 27,5 30,0 8,5 9,0 10,0 13,5 14,0 15,5 18,5 20,0 23,0 24,5 26,0 27,5 30,0 33,5 35,5 37,5 38,5 41,0

Approximate weight kg/km

Min. bending radius fixed installation mm

40 60 70 90 110 155 180 220 250 280 310 365 460 590 665 55 75 95 145 220 250 310 350 400 460 530 655 845 980 85 125 140 170 215 265 415 475 595 685 795 890 1045 1305 1460 1600 1710 1940

35 40 50 55 60 70 75 85 90 95 100 105 120 135 145 40 45 60 70 85 90 100 105 115 120 130 145 165 180 50 55 60 80 85 90 110 120 140 145 155 165 180 200 215 225 230 245

4/2015

20910 20912 20914 20906 20916 20918 20920 20922 20924 20926 20928 20930 20932 20934 20936 20970 20972 20974 20976 20978 20980 20982 20984 20986 20988 20990 20992 20994 20996 21356 21357 21358 21359 21360 21361 21362 21363 21364 21365 21366 21367 21368 21369 21370 21371 21372 21373

Number of conductors & cross-section n x mm2

250V CABLES

RFA-HF 250V

250V CABLES

56

RFA-HF (i)

4/2015

DESIGN:

Collectively and pair screened instrumentation and communication cable 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & pair screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - separator tape 5. Collective screen - drain wire tinned copper IEC 60092-350 - aluminium polyester tape, coverage 100% 6. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2)

150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2

Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 90 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

57

Part number

2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 1x3x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

8,5 10,0 12,0 12,5 14,5 15,0 16,0 17,0 18,5 20,5 23,5 25,0 6,5 10,0 12,0 14,0 15,0 17,0 18,0 19,5 20,5 22,5 25,0 8,5 9,0 10,0 13,5 14,0 16,0 19,0 20,5 23,5 25,0 26,5 28,5 30,5 34,5 36,5 38,0 39,5 42,0

90 130 200 225 280 320 360 410 475 600 775 890 60 110 175 270 300 370 425 500 560 655 810 95 120 155 185 240 305 485 560 695 800 915 1040 1205 1530 1710 1875 2025 2300

50 60 70 75 85 90 95 105 110 125 140 150 40 60 70 85 90 105 110 120 125 135 150 50 55 60 80 85 95 115 125 140 150 160 170 185 205 220 230 235 250

Other sizes on request.

Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

20940 20942 20944 20946 20948 20950 20952 20954 20956 20958 20960 20962 21058 21059 21061 21063 21065 21067 21069 21071 21073 21075 21077 21375 21376 21377 21378 21379 21380 21381 21382 21383 21384 21385 21386 21387 21388 21389 21390 21391 21392

Number of conductors & cross-section n x mm2

250V CABLES

RFA-HF(i) 250V

250V CABLES

58

LKM-FRHF DESIGN:

Fire-resistant unarmoured control and instrumentation cable 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic

IEC 60092-360

4/2015

3. Bedding - separator tape

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

4. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

59

Part number

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

8,5 9,0 10,0 11,0 11,5 15,0 15,5 16,5 17,5 18,0 19,0 21,5 22,0 23,0 25,0

65,0 80,0 110,0 130,0 160,0 225,0 255,0 295,0 330,0 375,0 410,0 475,0 520,0 615,0 695,0

11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

35 35 40 45 45 60 60 65 70 75 75 85 85 90 100

Other size on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

22406 22407 22408 22409 22410 22411 22412 22413 22414 22415 22416 22417 22418 22419 22420

Number of conductors & cross-section n x mm2

250V CABLES

LKM-FRHF 250V

250V CABLES

60

LKSM-FRHF DESIGN:

Fire-resistant armoured control and instrumentation cable 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic

EC 60092-360

4/2015

3. Bedding - separator tape 4. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 90% - tinned copper wire braid on request

IEC 60092-350

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

5. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

61

Part number

2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

Other size on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Crosssection of armour mm2 3,6 3,9 4,4 4,9 5,4 7,1 7,3 7,8 11,3 11,9 12,9 14,3 14,6 15,3 16,7

Nominal outer diameter mm 9,0 9,5 11,0 11,5 12,5 16,0 16,0 17,0 18,5 19,5 20,5 22,5 23,0 23,5 26,0

Approximate weight kg/km 105 125 160 185 220 300 330 370 445 495 545 615 665 740 860

Current Rating A at +45°C

Min. bending radius fixed installation mm

11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

55 60 65 70 75 95 95 100 110 115 125 135 140 140 155

4/2015

22436 22437 22438 22439 22440 22441 22442 22443 22444 22445 22446 22447 22448 22449 22450

Number of conductors & cross-section n x mm2

250V CABLES

LKSM-FRHF 250V

250V CABLES

62

LKAM-FRHF DESIGN:

Fire-resistant screened control and instrumentation cable 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request

4/2015

2. Insulation - Mica tape - XLPE plastic

IEC 60092-360

3. Screen - drain wire of tinned copper - aluminium polyester tape, coverage 100%

IEC 60092-350

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

4. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed.If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

63

Part number

2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

Other size on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Nominal outer diameter mm 8,5 9,0 10,0 11,0 11,5 15,0 15,5 16,5 17,5 18,0 19,5 21,5 22,0 23,0 25,0

Approximate weight kg/km 70 85 115 135 165 230 260 300 340 380 415 480 525 620 700

Current Rating A at +45°C

Min. bending radius fixed installation mm

11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

50 55 60 65 70 90 95 100 105 110 115 130 130 140 150

4/2015

22466 22467 22468 22469 22470 22471 22472 22473 22474 22475 22476 22477 22478 22479 22480

Number of conductors & cross-section n x mm2

250V CABLES

LKAM-FRHF 250V

250V CABLES

64

RFE-FRHF

Fire-resistant armoured pair instrumentation and communication cable 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - drain wire (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage

150/250V (300V)

Maximum conductor temperature

+ 90 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A

Fire-resistant Halogen-free Smoke emission

IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-404 conditions according to 60092-360/SHF2

Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,75mm2 1,5mm2 52 24,4 45 55 0,6 0,7 ≥1500 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

65

Part number

Nominal outer diameter mm

1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5

9,5 11,0 14,0 16,5 20,0 21,0 24,5 25,5 27,0 31,0 34,5 39,4 10,5 12,0 16,0 18,5 22,5 24,0 27,5 29,0 30,5 33,0 35,2

Approximate weight kg/km

Min. bending radius fixed installation mm

115 170 210 330 470 515 640 710 810 1025 1260 1605 155 220 315 430 655 725 880 1010 1135 1290 1475

55 65 85 100 120 125 145 150 165 185 205 235 65 70 95 110 135 145 165 175 185 195 210

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

20520 20522 20524 20526 20528 20530 20532 20534 20536 20538 20540 20542 20575 20577 20579 20581 20583 20585 20587 20589 20591 20593 20595

Number of conductors & cross-section n x mm2

250V CABLES

RFE-FRHF 250V

250V CABLES

66

RFE-FRHF (i)

4/2015

DESIGN:

Fire-resistant armoured and pair screened instrumentation and communication cable 250V

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation Flame- Mica tape retardant - XLPE plastic IEC 60092-360 Fire3. Twisted pair & pair screen resistant - two insulated cores twisted together to form a pair Halogen- plastic coated aluminium tape and a tinned copper drain wire free 4. Bedding Low smoke - filler tape emission 5. Armour Oil resistant - drain wire copper (only SHF2) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Fire-resistant Halogen-free Smoke emission Oil resistance (only SHF2)

150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22

-test for single insulated wire and cable -test for bunched wires and cables, category A IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2

Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,75mm2 1,5mm2 52 24,4 55 75 0,6 0,7 ≥1500 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

67

Part number

1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

9,5 11,0 14,5 17,0 20,0 22,0 25,0 26,0 27,5 32,0 35,0 41,0 10,5 12,0 16,5 19,0 23,0 24,5 28,0 29,5 31,5 33,5 36,0

125 175 225 355 510 585 710 800 910 1175 1425 1945 165 225 320 475 720 805 985 1145 1290 1450 1665

55 65 85 100 120 130 150 155 165 190 210 245 65 75 100 115 135 145 165 175 190 200 215

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

20546 20548 20550 20552 20554 20556 20558 20560 20562 20564 20566 20568 20603 20604 20605 20607 20609 20611 20613 20615 20617 20619 20621

Number of conductors & cross-section n x mm2

250V CABLES

RFE-FRHF(i) 250V

250V CABLES

68

RFA-FRHF

Fire-resistant screened pair instrumentation and communication cable 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Screen - drain wire tinned copper - aluminium polyester tape, coverage 100% IEC 60092-350 5. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant

150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22

-test for single insulated wire and cable -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 For details see general information section Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,75mm2 1,5mm2 52 24,4 45 55 0,6 0,7 ≥1500 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

69

Part number

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

8,5 10,0 13,0 15,5 18,5 20,0 23,0 24,0 25,5 27,5 29,5 33,5 9,0 14,5 14,5 15,5 17,5 21,0 23,0 26,0 27,5 29,5 31,0 34,0 38,0 40,0 42,5 43,5 46,5

75 120 135 215 330 380 480 545 620 700 805 1030 100 185 195 245 310 490 570 700 805 930 1040 1240 1550 1715 1915 2025 2320

50 60 80 90 110 120 140 145 155 165 175 200 55 85 90 95 105 125 135 155 165 175 185 205 230 240 255 260 280

1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

20635 20637 20639 20641 20643 20645 20647 20649 20651 20653 20655 20657 21521 21524 21525 21526 21527 21529 21531 21533 21535 21537 21539 21541 21542 21543 21544 21545 21547

Number of conductors & cross-section n x mm2

250V CABLES

RFA-FRHF 250V

250V CABLES

70

RFA-FRHF (i)

Fire-resistant collectively and pair screened instrumentation and communication cable 250V

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - Mica tape - XLPE plastic IEC 60092-360 3. Twisted pair & pair screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - separator tape 5. Collective screen - drain wire tinned copper - aluminium polyester tape coverage 100 % IEC 60092-350 6. Sheath - polyolefine plastic, SHF1, standard colour orange  IEC 60092-360 - on request thermosetting polyolefine, SHF2, standard colour black - other colours on request

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

Application: For fixed installation in most areas and on open deck in ships and offshore units. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant

150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22

-test for single insulated wire and cable -test for bunched wires and cables, category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 For details see general information section Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,75mm2 1,5mm2 52 24,4 55 75 0,6 0,7 ≥1500 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

71

Part number

2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5

Nominal outer diameter mm

Approximate weight kg/km

Min. bending radius fixed installation mm

13,5 15,5 18,5 20,0 23,5 24,5 26,0 28,0 30,0 34,0 9,5 11,0 15,0 16,0 17,5 21,0 23,0 26,5 28,0 29,5 32,0 34,5 39,0 41,0 43,0 44,0 47,5

155 245 380 430 545 625 725 810 945 1205 110 175 215 280 350 555 645 810 935 1065 1225 1435 1815 2010 2220 2350 2715

80 95 110 120 140 145 155 165 180 205 55 65 90 95 105 125 140 160 165 180 190 205 235 245 260 265 285

Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

4/2015

20667 20669 20671 20673 20675 20677 20679 20681 20683 20685 21550 21552 21553 21554 21555 21557 21559 21561 21563 21565 21567 21569 21571 21572 21573 21574 21575

Number of conductors & cross-section n x mm2

250V CABLES

RFA-FRHF(i) 250V

4/2015

LKSM-SHF2 120°C

0,6/1kV

72

LKSM-SHF2 120°C

Heat and oil resistant armoured power and control cable 0,6/1kV

DESIGN:

STANDARDS: IEC 60092-353, design

1. Conductor - stranded copper conductor 1,0-10mm2   IEC 60228, class 2 - stranded copper conductor 16-300mm2  IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Bedding - filler tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request

+120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission

Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage

AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Oil resistance

IEC 60811-404 conditions according to 60092-360

Halogen-free

IEC 60754 series

Flame-retardant

IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A

Smoke emission

IEC 61034 series

Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Core identification:

See technical information section

Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, production month-year, manufacturer's name and meter marking. Printed permanently with laser. The cable is marine type approved by all major classification societies. Cable name on type approval certificate is LKSM-SHF2.

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

73

1x1,0 1x1,5 1x2,5 1x4 1x6 1x10

1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex

– – – – – – – 4125773 4125787 4125880 4125882 4125884 4126272 4126274 4126276 4126278 4126280 4126282 4126284 4126286 4126288

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

3,0 3,0 3,1 3,1 3,1 3,5

6,0 6,5 7,0 7,5 8,0 9,5

70 75 90 105 130 190

18 23 30 40 52 72

40 40 45 45 50 60

4,1 4,9 5,5 8,7 11,4 11,5 14,5 14,7 15,2 18,2 18,7

10,5 13,0 14,0 17,0 19,0 21,5 23,5 26,5 29,0 32,5 35,5

240 360 460 650 885 1115 1405 1720 2065 2715 3300

94 123 153 196 240 284 331 381 429 507 582

65 80 90 105 115 130 145 160 180 200 215

3,6 3,8 4,3 4,9 5,4 8,7

9,0 9,5 10,5 12,0 13,0 15,5

110 130 160 210 315 480

15 20 26 34 44 61

55 60 65 75 80 95

2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex

10,0 14,5 14,7 18,1 18,7

18,0 23,0 25,5 29,5 34,0

625 985 1240 1700 2270

80 105 130 167 204

110 140 155 180 205

2x95 Flex 3x1,0

22,2 3,7

39,0 9,5

2965 130

241 13

235 60

3x1,5 3x2,5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex

4,1 4,6 5,2 5,8 9,3 10,7 14,6 15,0 18,3 22,0 22,8 37,8 39,3 47,9

10,0 11,0 12,5 14,0 16,5 19,0 24,5 27,0 32,0 36,5 42,0 47,0 53,0 59,5

155 195 260 370 570 750 1165 1505 2100 2850 3685 4745 5885 7265

16 21 28 36 50 66 86 107 137 168 199 232 267 300

65 70 80 85 100 115 150 165 195 220 255 285 320 360

2x1,0 2x1,5 2x2,5 2x4 2x6 2x10

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 Table continues on next page

4/2015

– – – 4127052 4127054 4127056 4127059 4127061 4127063 4127065 4127067 4127069 4127071 4127073 4127075 4127077 4127079 – – – – – –

Crosssection of armour mm2

0,6/1kV

4125955 4125736 4125738 4125740 4125742 4125744 4126237 4126238 4126239 4126240 4126241 4126242 4126243 4126244 4126245 4126246 4126247 4125956 4125770 4125785 4125801 4125803 4125805 4126254 4126255 4126256 4126257 4126258 4126259 4125957 4125772 4125786 4125802 4125804 4125806 4126271 4126273 4126275 4126277 4126279 4126281 4126283 4126285 4126287

Number of conductors & cross-section n x mm2

LKSM-SHF2 120°C

LKSM-SHF2 120°C 0,6/1kV Part number Normal G-type

4/2015

LKSM-SHF2 120°C

0,6/1kV

74

LKSM-SHF2 120°C 0,6/1kV Part number Normal G-type 4125958 4125774 4125788 4125830 4125832 4125834 4126301 4126303 4126305 4126307 4126309 4126311 4126313

– 4125775 4125789 4125831 4125833 4125835 4126302 4126304 4126306 4126308 4126310 4126312 4126314





4125959 4125776 4125790 4126011 4126013 4126015 4126331 4126333 4125960 4125961 4125962 4125963 4125964 4125965 4125977 4125978 4125981 4125778 4126025 4125780 4126027 4126030 4125782 4125828 4125783 4125784 4125792 4126033 4125794 4126035 4126037 4125796 4125798 4125768

– 4125777 4125791 4126012 4126014 4126016 4126332 4126334 – – – – – – – – – 4125779 4126026 4125846 4126028 4126029 4125781 4125829 4125847 4125848 4125793 4126034 4125795 4126036 4126038 4125797 4125799 4125769

Number of conductors & cross-section n x mm2

Crosssection of armour mm2

Nominal outer diameter mm

Approximate weight kg/km

Current Rating A at +45°C

Min. bending radius fixed installation mm

4x1,0 4x1,5 4x2,5 4x4 4x6 4x10

4,1 4,5 5,0 5,8 8,8 10,3

10,0 11,0 12,5 13,5 15,5 18,0

150 180 240 320 475 695

13 16 21 28 36 50

65 70 75 85 95 110

4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex

11,9 14,8 18,1 19,5 22,6 37,8 39,3 48,2

21,0 27,0 29,5 35,5 40,0 47,0 52,0 59,0

945 1440 1900 2635 3590 4850 6010 7565

66 86 107 137 168 199 232 267

130 165 180 215 245 285 315 355

5x1,0 5x1,5 5x2,5 5x4 5x6 5x10

4,5 5,0 5,6 8,6 9,7 11,5

10,5 12,0 13,5 15,0 17,0 20,0

175 220 285 410 565 830

10 13 17 23 30 42

65 75 80 95 105 120

5x16 Flex 5x25 Flex

13,2 18,1

23,0 29,5

1070 1655

55 71

140 180

7x1,0 10x1,0 12x1,0 14x1,0 16x1,0 19x1,0 24x1,0 27x1,0 37x1,0 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 37x1,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5

4,9 8,7 9,0 9,4 11,4 11,4 12,5 12,8 14,4 5,4 9,6 9,9 10,5 11,5 11,7 13,9 14,1 16,0 8,5 11,5 11,5 11,8 12,5 13,2 15,7 16,1

11,5 15,0 15,0 16,0 17,0 17,5 20,5 21,0 23,5 13,0 16,5 17,0 18,0 19,0 19,5 23,5 24,0 26,5 15,0 18,5 19,0 20,5 21,5 22,5 26,0 27,0

215 320 350 385 445 490 610 655 840 265 390 440 490 545 610 780 845 1085 380 535 595 680 760 855 1080 1175

9 8 8 7 7 7 6 6 5 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10

75 90 95 100 105 110 125 130 145 80 100 105 110 115 120 140 145 160 90 115 115 125 130 135 160 165

Other sizes on request. G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

75 LKSM-SHF2 120°C

0,6/1kV 4/2015

LKSM-SHF2 120°C

250V

76

LKSM-SHF2 120°C, 250V

Heat and oil resistant armoured control and instrumentation cable

DESIGN:

STANDARDS: IEC 60092-376, design

4/2015

1. Conductor - stranded copper conductor    IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Bedding - filler tape 4. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 5. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request

+120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission

Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage

150/250V (300V)

Oil resistance

IEC 60811-404 conditions according to 60092-360

Halogen-free

IEC 60754 series

Flame-retardant

IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A

Smoke emission

IEC 61034 series

Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Core identification:

See technical information section

Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, production month-year, manufacturer's name and meter marking. Printed permanently with laser. The cable is marine type approved by all major classification societies. Cable name on type approval certificate is LKSM-SHF2 250V.

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

77

Nominal outer diameter mm 7,0 7,5 8,0 8,5 9,0 11,5 11,5 12,0 12,5 13,5 14,0 15,5 15,5 16,5 18,0 7,5 7,5 8,5 9,5 10,0 12,5 12,5 13,0 14,0 14,5 18,0 17,0 17,5 18,0 19,5

Approximate weight kg/km 80 85 95 110 125 180 195 215 235 265 285 325 345 420 470 90 100 115 140 165 220 245 270 300 330 455 450 485 545 605

Current Rating A at +45°C

Min. bending radius fixed installation mm

8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3

40 45 45 50 55 70 70 70 75 80 85 90 95 100 105 45 45 50 55 60 75 75 80 85 85 110 100 105 110 115

4/2015

2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75

Crosssection of armour mm2 3,1 3,1 3,1 3,2 3,5 4,6 4,8 5,1 5,5 5,8 6,1 6,8 6,9 9,9 10,9 3,6 3,6 3,6 4,1 4,1 5,1 5,3 5,6 6,1 6,3 11,0 11,7 11,7 11,8 11,9

250V

Other sizes on request.

Number of conductors & cross-section n x mm2

LKSM-SHF2 120°C

LKSM-SHF2 120°C 250V Part number Normal 4127779 4127780 4127781 4127782 4127783 4127784 4127785 4127786 4127787 4127788 4127789 4127790 4127791 4127792 4127793 4126402 4126403 4126404 4126405 4126407 4126410 4126412 4126414 4126416 4126419 4126420 4126424 4126427 4126432 4126437

4/2015

RFE-SHF2 120°C

250V

78

RFE-SHF2 120°C

Heat and oil resistant armoured pair instrumentation and communication cable

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor     IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request

+120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission

Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage

150/250V (300V)

Oil resistance

IEC 60811-404 conditions according to 60092-360

Halogen-free

IEC 60754 series

Flame-retardant

IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A

Smoke emission

IEC 61034 series

Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 60 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

79

Approximate weight kg/km

Min. bending radius fixed installation mm

7,0 8,0 10,5 11,5 14,0 14,5 17,0 17,5 18,5 19,5 21,0 23,5 28,0 7,5 9,0 11,0 12,5 15,5 16,0 18,5 19,0 20,5 21,5 23,5 26,0 29,5 9,5 11,0 14,0 17,0 20,0 21,5 24,5 25,5 27,0 31,0 35,0 39,5

85 105 130 175 245 270 355 390 440 485 545 670 930 95 125 155 215 330 375 440 490 565 620 715 860 1100 135 190 235 375 545 625 760 855 960 1230 1530 1950

45 50 60 70 85 85 100 105 110 120 125 140 170 45 55 65 75 90 95 110 115 125 130 140 155 175 60 65 85 100 120 130 145 155 165 185 210 235

1x2x0,5 2x2x0,5 Quad 2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 32x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 19x2x1,5 24x2x1,5 32x2x1,5

Other sizes on request.

Core identification: See technical information section Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... (Quad)cable is built up as a star quad with the following identification 1 core 2 core 3 core 4 core

white blue white blue

Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, production month-year, manufacturer's name and meter marking. Printed permanently with laser. The cable is marine type approved by all major classification societies. Cable name on type approval certificate is RFE-SHF2.

4/2015

4120362 4120364 4120363 4120366 4120368 4120369 4120370 4120371 4120372 4120373 4120374 4120376 4120378 4120382 4120384 4120383 4120386 4120388 4120389 4120390 4120391 4120392 4120393 4120394 4120396 4120398 4120490 4120491 4120492 4120493 4120494 4120495 4120496 4120497 4120498 4120499 4120500 4120501

Nominal outer diameter mm

250V

Part number

Number of conductors & cross-section n x mm2

RFE-SHF2 120°C

RFE-SHF2 120°C 250V

RFE-SHF2 (i) 120°C

250V

80

RFE-SHF2 (i) 120°C

Heat and oil resistant armoured and pair screened instrumentation and communication cable

4/2015

DESIGN:

STANDARDS: IEC 60092-376, design

1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - improved heat resistant XLPE (+120°C) IEC 60092-360 3. Twisted pair & pair screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - filler tape 5. Armour - copper wire braid, coverage > 90% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - improved heat resistant SHF2 (+120°C) IEC 60092-360 - standard colour black with grey stripes, other colours on request

+120°C heat resistant Oil resistant Flameretardant Fireresistant Halogenfree Low smoke emission

Application: For fixed installation in most areas and on open deck in ships or on oil rigs and various industrial use. Excellent resistance against weathering, ozone, UV-rays, Oil / Diesel oil. Typical Marine, Oil, Gas and Petrochemical applications are for example Ship Engine rooms, power plants and/or other areas where ambient temperature may exceed +80°C, which is the limit for traditional IEC 60092-cables. Rated voltage

150/250V (300V)

Oil resistance

IEC 60811-404 conditions according to 60092-360

Halogen-free

IEC 60754 series

Flame-retardant

IEC 60332-1-2 Test for single insulated wire and cable IEC 60332-3-22 Test for bunched wires and cables, category A

Smoke emission

IEC 61034 series

Temperature rating: Fixed installation: -40ºC to +120ºC Occasionally moved: -20ºC to +120ºC Max. conductor temperature: +120ºC Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C

0,5mm2 0,75mm2 80 52 55 70 0,6 0,6 ≥1500 ≥1500

1,5mm2 24,4 90 0,7 ≥1500

Unit ohm/km nF/km mH/km Mohm/km

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

81

1x2x0,5 2x2x0,5 Quad 2x2x0,5 3x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 27x2x0,5 30x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 Quad 2x2x0,75 4x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 19x2x1,5

Approximate weight kg/km

Min. bending radius fixed installation mm

7,5 8,0 10,5 11,0 12,0 14,0 15,5 17,5 18,0 19,0 20,0 22,0 24,0 25,5 26,5 27,5 29,0 7,5 9,0 11,5 13,0 15,5 16,5 19,0 20,0 21,0 24,0 27,0 10,0 11,0 14,5 17,0 20,0 22,0 25,0 26,0 28,0 32,0

90 120 155 185 215 320 385 470 530 590 655 770 935 1030 1120 1190 1340 95 140 170 240 375 420 520 585 650 835 1035 145 200 255 415 610 700 855 965 1105 1440

45 50 65 65 70 85 90 105 110 115 120 130 145 150 160 165 175 45 55 70 75 95 100 115 120 125 145 160 60 65 85 100 120 130 150 155 165 190

Other sizes on request.

Core identification: See technical information section Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

Sheath marking: Lot number, cable type, cable size, voltage, temperature, standards, production month-year, manufacturer's name and meter marking. Printed permanently with laser. The cable is marine type approved by all major classification societies. Cable name on type approval certificate is RFE-SHF2(i).

4/2015

4122338 4122342 4122344 4122346 4122348 4122350 4122352 4122354 4122356 4122358 4122360 4122362 4122364 4122366 4122368 4122370 4122372 4122006 4122008 4122010 4122012 4122014 4122016 4122018 4122020 4122022 4122024 4122026 4122050 4122052 4122054 4122056 4122058 4122060 4122062 4122064 4122066 4122068

Nominal outer diameter mm

250V

Part number

Number of conductors & cross-section n x mm2

RFE-SHF2 (i) 120°C

RFE-SHF2(i) 120°C 250V

OPTICAL FIBRE CABLE

82

FXMSU

Optical fibre indoor/outdoor cable

Cable construction: 1. Central element glass fibre, 1,5 mm 2. PP-slotted core, 6,0 mm 3. Optical fibres, 250 μm 4. Swellable tape 5. Rip cord

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2)

4/2015

6. UV-protected and halogen free sheath

- non-metallic - networks in marine applications - Fibres: 250 μm SM or MM fibres - 4 - 48 fibres Cable characteristics: Maximum pulling force Crush strength / 100 mm (plate) Crush strength / 25 mm (mandrel) Impact strength Sheath marking Minimum installation temperature Operating temperature range Longitudinal water tightness Flame-retardant Halogen-free Smoke emission

500 N EN 187000 method 501 4000 N EN 187000 method 504 650 N EN 187000 method 504 25 J EN 187000 method 505 Cable type, manufacturer's name, manufacturing number and time, length marking in meter -15 °C -45...+70 °C EN 187000 method 605B

.. Slotted core

cables have blue and red marker threads for the first and last slot respectively.

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series

For details see general information section

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

83

Part number

FXMSU 1X4SML (L) FXMSU 1X6SML (L) FXMSU 2X6SML (L) FXMSU 4X6SML (L) FXMSU 1X4OM3L (L) FXMSU 2X4OM3L (L) FXMSU 3X4OM3L (L) FXMSU 4X6OM3L (L) FXMSU 1X4GKL (L) FXMSU 1X6GKL (L) FXMSU 2X4GKL (L) FXMSU 3X4GKL (L) FXMSU 4X4GKL (L) FXMSU 4X6GKL (L) FXMSU1X4SML+1X4GKL (L) FXMSU1X4SML+2X4GKL (L) FXMSU2X4SML+2X4GKL (L) FXMSU1X6SML+3X4GKL (L) FXMSU2X6SML+3X4GKL (L) FXMSU1X4SML+1X4OM3 (L) FXMSU1X4SML+2X4OM3L (L) FXMSU2X4SML+2X4OM3L (L) FXMSU1X6SML+3X4OM3L (L) FXMSU2X6SML+3X4OM3L (L)

Other fiber combinations on request Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Diameter of slotted core, mm

6

Nominal Approximate Minimum bending radius outer weight, during final diameter, kg/km installation, installation, mm mm mm

9,4

75

140

100

4/2015

10001 10022 10024 10028 14384 14386 14388 14398 14404 14406 14408 14410 14412 14416 14420 14422 14424 14426 14428 14449 14450 14451 14454 14455

Cable and number of fibres

OPTICAL FIBRE CABLE

FXMSU

OPTICAL FIBRE CABLE

84

FXMMS

Optical fibre installation cable

Cable construction:

Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant

1. FRP central element 2 mm 2. PP-slotted core 3. Installation cable unit FMS 1 (2 mm) 4. Fire barrier tape 5. Rip cord

(only SHF2)

4/2015

6. Halogen free sheath 1,5 mm

- For tray installation - Fibres: 2–8 SM or MM fibres, 900 μm - Connectors can be mounted directly to the fibres Cable characteristics: Maximum pulling force Crush strength / 100 mm (plate) Crush strength / 25 mm (mandrel) Impact strength, R = 300 mm Sheath marking Minimum bending radius Nominal cable diameter Cable weight Minimum installation temperature Operating temperature range

1500 N EN 187000 method 501 4000 N EN 187000 method 504 750 N EN 187000 method 504 30 J EN 187000 method 505 Cable type, manufacturer's name, manufacturing number and time, length marking in meter 195 mm during installation, 130 mm in final bending 13.1 mm 142 kg/km -15 °C -45...+70 °C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

For details see general information section Cable and number of fibres

FXMMS 2-4

Diameter of slotted core, mm 7,5

FXMMS 6-8

9,7

Nominal Approximate Minimum bending radius outer weight, during final diameter, kg/km installation, installation, mm mm mm 10,7 102 160 110 13,1

142

195

130

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

85

Part number

10810 10812 10814 10816 13747 13748 13749 13750 13872 13874 13876 13878

Cable and number of fibres

FXMMS 2SMT (2MM) FXMMS 4SMT (2MM) FXMMS 6SMT (2MM) FXMMS 8SMT (2MM) FXMMS 2GKT (2MM) FXMMS 4GKT (2MM) FXMMS 6GKT (2MM) FXMMS 8GKT (2MM) FXMMS 2OM3T (2MM) FXMMS 4OM3T (2MM) FXMMS 6OM3T (2MM) FXMMS 8OM3T (2MM)

Nominal Approximate Minimum bending radius outer weight, during final diameter, kg/km installation, installation, mm mm mm 10,7 102 160 110 10,7 102 160 110 13,1 142 195 130 13,1 142 195 130 10,7 102 160 110 10,7 102 160 110 13,1 142 195 130 13,1 142 195 130 10,7 102 160 110 10,7 102 160 110 13,1 142 195 130 13,1 142 195 130

4/2015

Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx

Diameter of slotted core, mm 7,5 7,5 9,7 9,7 7,5 7,5 9,7 9,7 7,5 7,5 9,7 9,7

OPTICAL FIBRE CABLE

FXMMS

OPTICAL FIBRE CABLE

86

Cabled optical fibres characteristics Fibre coating:

L = 250 μm ± 10 μm T = 900 μm ± 50 μm

Single mode fibre

10/125 μm

Fibre type

SML 250μm±10μm SMT 900μm±50μm

4/2015

Mode field diameter (MFD) Mode field eccentricity -Installation cables Cladding diameter - Installation cables Cladding ellipticity Fibre attenuation

1310 nm

1310 nm 1550 nm

Zero dispersion range Dispersion coefficient - Dispersion at Cut-off wavelength - Installation cables Polarization mode dispersion Proof test Fibre identification

Multi mode fibre

SM / OS2 (ITU-T G.652.D)

1550 nm

50/125 μm

9,3 +/- 0,5 μm ≤ 1,0 μm ≤ 0,5 μm 125 +/- 2 μm 125 +/- 1 μm ≤2% ≤ 0,40 dB/km ≤ 0,25 dB/km 1300...1324 nm ≤ 0,093 ps/nm2/km ≤ 18 ps/nm/km ≤ 1260 nm 1180...1250 nm ≤ 0,5 ps/√km 1 % / 1 sec 6 colour system according to SFS 5648

OM3

Fibre type

OM3L 250μm±10μm OM3T 900μm±50μm

Core diameter Core ellipticity Core eccentricity Cladding diameter Cladding ellipticity Fibre attenuation

50 +/- 3 μm ≤6% ≤ 3 μm 125 +/- 2 μm ≤2% ≤ 2,7 dB/km ≤ 0,8 dB/km ≥ 1500 MHz x km (LED) ≥ 500 MHz x km (LED) ≥ 2000 MHz x km (Laser) 0,200 +/- 0,015 6 colour system according to SFS 5648

Bandwidth

Numerical aperture, NA Fibre identification

850 nm 1300 nm 850 nm 1300 nm 850 nm

Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com

87

62,5/125 μm

GK / OM1 GKL 250μm±10μm GKT 900μm±50μm

Core diameter Core ellipticity Core eccentricity Cladding diameter Cladding ellipticity Fibre attenuation

62,5 +/- 3 μm ≤6% ≤ 3 μm 125 +/- 2 μm ≤2% ≤ 3,5 dB/km ≤ 1,0 dB/km ≥ 200 MHz x km ≥ 500 MHz x km 0,275 +/- 0,015 6 colour system according to SFS 5648

Bandwidth Numerical aperture, NA Fibre identification

850 nm 1300 nm 850 nm 1300 nm

4/2015

Fibre type

OPTICAL FIBRE CABLE

Multi mode fibre

TECHNICAL INFORMATION

88

GENERAL INFORMATION Standard for materials: IEC 60092-360 will replace and withdraw 60092-359 and 60092-351.

Halogen-free Halogen-free refers to the absence of halogens, such as chlorine and fluorine, and is determined on the basis of halogen content and the acidity of gases of a cable.

Insulation material:

The designation SHF1 stands for thermoplastic compound. This material is halogen-free, highly flame-retardant and has low smoke emission. The designation SHF2 stands for oil resistant thermosetting compound. This material is halogen-free, highly flameretardant and has low smoke emission.

4m

2.5 m

Sheathing material:

Test on bunched cables IEC 60332-3 Burning is allowed up to max. 2.5 meters from the burner within specified time.

3.5 m

The following designations are used for insulation materials in this catalog. All materials are halogen-free. XLPE stands for cross-linked polyethylene compound. It has excellent mechanical and electrical characteristics.

4/2015

All Helkama cables comply with the most severe requirements of category A.

1m

2m

IEC 60332-1 is the test for single insulated wire and cable. Test procedure and requirements according to the picture below.

50 mm

Definition of terms: Oil resistance Sheathing material is oil resistant according to method IEC 60811-404 and requirements from IEC 60092-360/SHF2. The oil resistance is demonstrated by immersion in IRM902 oil for 24h at 100°C. Flame-retardant To be flame-retardant, the cables must withstand the test specified in IEC standard 60332-3 or IEC 60332-1. Flame-retardant cables do not propagate fire, and are self-extinguishing.

475 mm

IEC 60754-1 determines the halogen content of the material. To meet the requirements as halogen-free the halogen content of the material may not exceed 0,5 % or 5 mg/g. IEC 60754-2 determines the degree of acidity of gases evolved during combustion. The limit values are 4,3 for pH and 10 mikroS for conductivity. Smoke emission Smoke emission refers to visibility in a fire. The greater the light transmittance, the better the visibility. When tested in accordance with IEC 61034-1 (test method) and IEC 61034-2 (test requirements) the smoke emission of a cable during fire must not exceed the following values.

550 600 mm mm

27m3 cube smoke chamber

Min. 50 mm of the cable, measured from the upper support, must remain unburned after the specified time.

Requirements: 60 % light transmittance

Un

IEC 60332-3 is the test for bunched wires and cables and has three categories A, B and C, defined by different limits for flammable material and burning times. Burning time describes how long the burner is directed towards the bunch of cables. The requirement for passing the test is that after the burner has been removed the cables must extinguish themselves. Burning may not occur more than 2.5 m from the burner as shown in the figure. Amount of burning material

Burning time

A

7 litres/m

40 min

B

3,5 litres/m 40 min

C

1,5 litres/m 20 min

Category

3A

Fire-resistant IEC 60331-1 Test method for fire with shock at a temperature of at least 830 °C for 90 minutes for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm. IEC 60331-2 Test method for fire with shock at a temperature of at least 830 °C for 90 minutes for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm.

830 °C / 90 min

gas burner 500 mm

110 mm

89

Recommended minimum bending radius, ( R ) :

Radius (R) Outer diameter (D)

DIAMETER TOLERANCE

R = 6x D R = 9x D R = 4x D R = 6x D

LKSM-HF LKSM-EMC LKSM-VFD LKMSM-HF LKAM-HF LKM-FRHF LKSM-FRHF LKAM-FRHF RFE-HF RFE-HF(i) RFA-HF RFA-HF(i) RFE-FRHF RFE-FRHF(i) RFA-FRHF RFA-FRHF(i)

During installation Fixed installation

R = 9x D R = 6x D

Tolerance ±0,5mm ±1,0mm ±1,5mm

Cable outer diameter, mm. 30,1 – 40 40,1 – 50 50,1 – 60

< 25mm > 25mm < 25mm > 25mm

Tolerance ±2,0mm ±2,5mm ±3,0mm

(according to HD 308 S2)

250V

0,6/1kV a

b

1 3 5 7 9 11

2 4 6 8 10 12

Normal type

1-core

BK

2-cores

BN BU

3-cores

BN BK

4-cores

etc. 5-cores

GY

Y/G BU BN

BU BN

Y/G BN

GY BK

GY BK

1

3

Y/G BU GY BN BK

3

Y/G

4

6

5 4

250V LKSM-HF

7-cores and above

2-cores

1

G-type (with earth conductor)

2

2

2 7 6

1 5

Black numbers on white base

2 1

3 4

5

Black numbers on white base Last core yellow/green.

Black numbers on white base

BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green

3-cores

1

2 3

1,8/3kV

LKSM-VFD

1-core

BK

3-cores

BN BK

Black numbers on white base

4-cores to 37-cores

GY Black numbers on white base

3-cores + 3-ground cores

Y/G

BN BK Y/G

GY

Y/G

4/2015

Cable outer diameter, mm. 1 – 10 10,1 – 20 20,1 – 30

CORE IDENTIFICATION

Pair number 1 2 3 4 5 6

During installation During installation Fixed installation Fixed installation

TECHNICAL INFORMATION

BENDING RADIUS

LKM-HF LKMM-HF LKEM-HF

TECHNICAL INFORMATION

90

CURRENT RATING "Current rating (A) at an ambient temperature of 45°C according to the standard IEC 60092-352 0,6/1 kV +90°C marine cables." Current carrying capacities in continous service at maximum rated conductor temperature of +90°C. For class 2 conductor cables Size

N

1

2

3

4

5

7

10

12

14

16

19

24

27

37

1 18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601

0,85 15 20 26 34 44 61 82 108 133 167 206 249 288 331 377 444 511

0,7 13 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421

0,7 13 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421

0,58 10 13 17 23 30 42 56 74 91

0,52 9 12 16

0,46 8 11 14

0,44 8 10 13

0,41 7 9 12

0,40 7 9 12

0,37 7 9 11

0,35 6 8 11

0,33 6 7 10

0,30 5 7 9

1

2

3

4

5

7

10

12

14

16

19

24

27

37

1,5mm2 2,5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2

1 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582

0,85 14 19 26 33 43 60 80 105 130 167 204 241 281 324 365 431 495

0,7 12 15 21 27 35 50 66 86 107 137 168 199 232 267 300 355 407

0,7 12 15 21 27 35 50 66 86 107 137 168 199 232 267 300 355 407

0,58 10 13 17 23 29 41 55 71 89

0,52 9 11 16

0,46 8 10 14

0,44 7 10 13

0,41 7 9 12

0,40 7 9 12

0,37 6 8 11

0,35 6 8 11

0,33 6 7 10

0,30 5 7 9

Ambient temperature Correction factor

+35°C 1,10

Factor, n

4/2015

For continuous service. Continuous service for a cable is to be considered as a current-carrying service (with constant load) having a duration longer than three times the thermal time constant of the cable, i.e. longer than the critical duration(see short time duty).

1,0mm2 1,5mm2 2,5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2

For class 5 conductor cables Size

N Factor, n

1,0mm2

+40°C 1,05

+45°C 1,00

+50°C 0,94

+55°C 0,88

+60°C 0,82

+65°C 0,74

+70°C 0,64

+75°C 0,58

+80°C 0,47

91

SHORT CIRCUIT CURRENT

Based on formula:

Ik = 226

X

S t

X

S t

X

In

234 + Tk 234 + Tb

Formula 1:

Ik = 146 Ik S t Tk

= = = =

Maximum permissible short circuit current. Cross-section of the conductor in mm2. Duration of the short circuit in s. Maximum rated conductor temperature, short circuit, °C Tb = Maximum rated conductor temperature, normal, °C Formula 1: For 0,6/1kV cable with XLPE or HF90 with maximum operating temperature of +90°C (Tb) and short circuit temperature of +250°C (Tk).

Cross-section of the conductor in mm2 1,0 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

0,2 0,3 0,5 0,8 1,3 2,0 3,3 5,2 8,2 11,4 16,3 22,9 31,0 39,2 49,0 60,4 78,4 97,9

0,5 1 2 3 0,2 0,1 0,1 0,1 0,3 0,2 0,2 0,1 0,5 0,4 0,3 0,2 0,8 0,6 0,4 0,3 1,2 0,9 0,6 0,5 2,1 1,5 1,0 0,8 3,3 2,3 1,7 1,3 5,2 3,7 2,6 2,1 7,2 5,1 3,6 3,0 10,3 7,3 5,2 4,2 14,5 10,2 7,2 5,9 19,6 13,9 9,8 8,0 24,8 17,5 12,4 10,1 31,0 21,9 15,5 12,6 38,2 27,0 19,1 15,6 49,6 35,0 24,8 20,2 61,9 43,8 31,0 25,3 Short circuit current in kA

10 0,0 0,1 0,1 0,2 0,3 0,5 0,7 1,2 1,6 2,3 3,2 4,4 5,5 6,9 8,5 11,1 13,9

4/2015

SHORT CIRCUIT FACTOR Short Circuit Factor can be calculated by following formula:

SHORT CIRCUIT FACTOR =

Duration of the short circuit in s.

TECHNICAL INFORMATION

Maximum permissible short circuit current. 0,6/1 kV +90°C marine cables.

SHORT CIRCUIT CURRENT CURRENT RATING

TECHNICAL INFORMATION

92

SHORT TIME DUTY Short time duty according to the standard IEC 60092-352 0,6/1 kV +90°C marine cables. If a cable is intended to supply motor or equipment operating for periods of half an hour or one hour, its current rating given in table “current rating”, may be increased using the relevant correction factors given by formula:

correction = factor

1,12 1-exp(-ts/T)

( ts = service time, min. T = Time constant, min.)

T = 0,245 x d 1,35

4/2015

(d = Overall diameter of the cable, mm.)

Overall diameter of the cable, mm.

Service time, min.

1 2 3 4 5 6 7 8 9 10 20 30 40 50 60

Time Critical constant, duration, min. min.

30

60

T

3x T

1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,059 1,059 1,061 1,126 1,255 1,403 1,554 1,705

1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,066 1,105 1,173 1,254 1,341

0,245 0,625 1,08 1,59 2,15 2,75 3,39 4,06 4,76 5,48 14,0 24,2 35,6 48,2 61,6

0,735 1,87 3,24 4,78 6,46 8,26 10,2 12,2 14,3 16,5 41,9 72,5 107 145 185

Correction factor.

Intermittent service Correction factor for intermittent service according to the standard IEC 60092-352 The correction factor given hereby has been roughly calculated for periods of 10 min, of which 4 min are with a constant load and 6 min without load. Intermittence period = 10min. Intermittence ratio = 40%.

Fi=

1-exp(-10/T) 1-exp(-4/T)

Overall diameter of the cable, mm.

Correction factor.

1 2 3 4 5 6 7 8 9 10 20 30 40 50 60

1,000 1,001 1,012 1,042 1,083 1,127 1,170 1,208 1,242 1,273 1,433 1,490 1,518 1,534 1,544

93

VOLTAGE DROP

Size

1.0mm2 1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2

Resistance at +20°C ohm/km

Resistance at +90°C ohm/km

Voltage reduction mV/Am *)

Resistance at +45°C ohm/km

Current rating A **)

Voltage reduction mV/m ***)

18,1 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601

23,1 15,4 9,45 5,88 3,93 2,33 1,47 0,927 0,668 0,493 0,342 0,246 0,195 0,158 0,1264 0,0961 0,0766

46,2 30,9 18,9 11,8 7,85 4,67 2,93 1,85 1,34 0,987 0,683 0,492 0,390 0,316 0,253 0,192 0,153

19,9 13,3 8,14 5,06 3,38 2,01 1,26 0,798 0,575 0,425 0,294 0,212 0,168 0,136 0,1088 0,0828 0,0660

18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601

0,72 0,61 0,49 0,41 0,35 0,29 0,24 0,20 0,18 0,17 0,14 0,12 0,11 0,11 0,097 0,086 0,079

Size

0,75mm2 1.0mm2 1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2

Resistance at +20°C ohm/km

Resistance at +90°C ohm/km

Voltage reduction mV/Am *)

Resistance at +45°C ohm/km

Current rating A **)

Voltage reduction mV/m ***)

26,0 19,5 13,3 7,98 4,95 3,30 1,91 1,21 0,78 0,554 0,386 0,272 0,206 0,161 0,129 0,106 0,0801 0,0641

33,2 24,9 17,0 10,18 6,31 4,21 2,44 1,54 0,995 0,706 0,492 0,347 0,263 0,205 0,164 0,135 0,102 0,082

66,3 49,7 33,9 20,4 12,6 8,42 4,87 3,09 1,99 1,41 0,984 0,694 0,525 0,411 0,329 0,270 0,204 0,163

28,6 21,4 14,6 8,76 5,44 3,62 2,10 1,33 0,857 0,608 0,424 0,299 0,226 0,177 0,142 0,116 0,088 0,070

14 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582

0,80 0,73 0,64 0,53 0,42 0,36 0,30 0,25 0,21 0,19 0,17 0,14 0,13 0,12 0,11 0,10 0,09 0,08

Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i) Size

0,5 mm2 0,75 mm2 1,5 mm2

Resistance at +20°C ohm/km

Maximum conductor temperature, °C

Resistance at +45°C ohm/km

Voltage reduction mV/Am at +45°C

Resistance at +90°C ohm/km

Voltage reduction mV/Am at +90°C

40,4 26,0 12,8

90 90 90

44,4 28,6 14,1

88,7 57,1 28,1

51,5 33,2 16,3

103,0 66,3 32,6

*) at +90°C **) For continuous service (single core, ambient temperature +45°C) ***) at maximum current rating for continuous service at +45°C

4/2015

Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor)

TECHNICAL INFORMATION

Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor)

HELKAMA BICA OY Lakimiehenkatu 4 FI-20780 KAARINA Finland Tel. +358 2 410 8700 Fax +358 2 237 2428 [email protected] [email protected]

Helkama Bica (Shanghai) Co., Ltd. Plot 1-2, MinHang Export Processing Zone No. 3111 Huan Cheng West Road Fengxian District, Shanghai 201401, China Tel. +86 21 3365 5333, Fax +86 21 3365 5331 [email protected]

www.helkamabica.com

Suggest Documents