TKF
Catalogue
Marine and offshore cables
Contents
About TKF Symbols
3 4
Product information Porfolio market segments Marine and Offshore
5
Conditions Contact and drum information
Copyright (c) TKF, 24-03-2009
32 33
Subject to technical alterations
Page 2
About TKF TKF (BV Twentsche Kabelfabriek) was founded in 1930 and has grown from a local Dutch cable manufacturer to an international leader in cable technology, servicing customers all around the globe.
TKF has dedicated itself to efficient and reliable cable solutions, matching specific customer requirements - looking for longterm relationships – building bridges between a growing number of professional partners.
TKF started optical fibre cable production in 1986 and has acquired a leading position in the international broadband market,
providing single mode and multimode fibre cables to various European operators, installers and end-customers. TKF is a full member of TKH Group, an
internationally operating group of companies, focusing on development and delivery of innovative Telecom, Building and Industrial Solutions. The building blocks forming these innovative solutions are technologies,
know-how, products, and value added services such as consulting development, assembly and logistic support. TKH strategy is aimed at offering solutions, and strives for a high return on investment for her clients.
TKF consciously opts for an active role in a number of market segments. As a result, TKF can respond better to clients demands. Visit our website www.tkf.nl for more information.
© BV Twentsche Kabelfabriek
Subject to technical alterations
www.tkf.nl-
Symbols
© BV Twentsche Kabelfabriek
Subject to technical alterations
www.tkf.nl-
Marine Cables High-end solutions for all marine cable applications Marine Line+ Non braided power cables YZp 0.6/1 kV
Marine Line+ Copper wire braided power cables YOZp 0.6/1 kV
Marine Signal+ Non braided signal and control cables YZs 250 V
Marine Signal+ Copper wire braided signal and control cables YOZs 250 V
Marine Line - EMC Shielded and braider motor cables 0.6/1 kV
Marine Com Copper wirer braided communication cables YOZc 250 V
M Marine Power Copper wire braided medium voltage power cables 6/10 - 8.7/15 kV
Marine Line+ Non-braided power cables YZpfr 0.6/1 kV
© BV Twentsche Kabelfabriek
Marine Flex Non braided power cables with flexible class 5 conductors YZp 0.6/1kV
Marine 2 Com Copper wire braided communication cables YOZ2c 250 V
Subject to technical alterations
www.tkf.nl-
Marine cables International standards and approvals All marine cables are designed and produced according to international standards. TKF marine cables fully comply with the requirements specified in the IEC 60092 series of standards.
Contents Marine and Offshore
Low voltage marine cables MarineLine MarineLine YZp 0,6/1 kV MarineLine YOZp 0,6/1 kV MarineLine+ MarineLine+ YZp 0,6/1 kV MarineLine+ YOZp 0,6/1 kV MarineFlex MarineFlex YZp 0,6/1 kV MarineFlex YOZp 0,6/1 kV MarineLine FR MarineLine FR YZp FR MarineLine FR YOZp FR MarineLine+ FR MarineLine+ YZp FR MarineLine+ YOZp FR Communication marine cables MarineCom MarineCom YOZc 250 V Marine2Com YOZ2c 250 V Signal marine cables MarineSignal MarineSignal YZs 250 V MarineSignal YOZs 250 V MarineSignal+ MarineSignal+ YZs 250 V MarineSignal+ YOZs 250 V Marine power cables MarinePower YOZmv 6/10 kV Appendix
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
6 9 12 14 16 17 19 20 21 22
23 24
25 26 27 28 29 30
Page 5
Marine and Offshore MarineLine YZp 0,6/1 kV
Marine Cable 0,6/1kV, type CS85 MBZH MarineLine halogen free cable . These low voltage cables are designed for power and light applications on board of vessels to international standards. Type approvals from various international maritime certification authorities are available. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine YZp 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Article dependant, see detail sheet Core insulation XLPE Core identification HD 308 S2 Binder/filler Polyester tape Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Black Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70 Specification See appendix
Art. Number TKF 16000 16001 16002 16003 16004 16005 16006 16007 16008 16009 16010 16011 16012 16013 16014 16015 16016
Unit
kV kV V °C °C °C
Construction 1 x 1,5 mm² 2 x 1,5 mm² 3 x 1,5 mm² 4 x 1,5 mm² 5 x 1,5 mm² 6 x 1,5 mm² 7 x 1,5 mm² 8 x 1,5 mm² 10 x 1,5 mm² 12 x 1,5 mm² 16 x 1,5 mm² 19 x 1,5 mm² 24 x 1,5 mm²
Outer diameter (mm) 4,9 7,9 8,5 9,3 10,1 11,2 11,2 13 15,6 14,8 16,9 18,1 20,2
Net weight (kg/km) 35 68 92 112 137 168 178 222 301 291 383 441 581
Tensile load (N) 23 45 68 90 113 135 158 180 225 270 360 428 540
Bending radius after installation (mm) 20 32 34 37 40 45 45 52 62 59 68 72 81
1 x 2,5 mm² 2 x 2,5 mm² 3 x 2,5 mm² 4 x 2,5 mm²
5,3 9 9,5 10,4
46 94 123 154
38 75 113 150
21 36 38 42
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Capacity (nF/km) 55 37 37 37 63 42 44
Page 6
Marine and Offshore MarineLine YZp 0,6/1 kV
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
16017 16018
5 x 2,5 mm² 7 x 2,5 mm²
11,5 12,6
195 249
188 263
46 50
44 -
16019 16020
1 x 4 mm² 2 x 4 mm²
5,9 10,1
63 127
60 120
24 40
68
16021 15977
3 x 4 mm² 3 x 4 mm²
10,7 10,7
170 177
180 180
43 43
45 45
15978 16022 16023 16024
4 x 4 mm² 4 x 4 mm² 1 x 6 mm² 2 x 6 mm²
11,9 11,9 6,4 11,4
231 223 87 182
240 240 90 180
48 48 26 46
47 47 72
16025 15979
3 x 6 mm² 3 x 6 mm²
12,1 12,1
247 247
270 270
48 48
48 48
15980 16026 16027 16028 16029 15981
4 x 6 mm² 4 x 6 mm² 1 x 10 mm² 2 x 10 mm² 3 x 10 mm² 3 x 10 mm²
13,2 13,2 7,2 12,9 13,8 13,8
317 318 128 265 376 376
360 360 150 300 450 450
53 53 29 52 55 55
50 50 82 55 55
15982 16030
4 x 10 mm² 4 x 10 mm²
15,2 15,2
488 488
600 600
61 61
59 59
16031 16032 16033 16034
1 x 16 mm² 2 x 16 mm² 3 x 16 mm² 4 x 16 mm²
8,2 15,1 16 17,8
187 394 555 732
240 480 720 960
33 60 64 71
92 61 68
16035 16036 16037
1 x 25 mm² 2 x 25 mm² 3 x 25 mm²
10,1 18,7 20
287 602 853
375 750 1125
40 75 80
95 65
16038 16039 16040 16048 16041 16049
4 x 25 mm² 1 x 35 mm² 2 x 35 mm² 3 x 35 mm² 1 x 50 mm² 3 x 50 mm²
22,3 11,8 22,1 20,8 13,2 23,4
1130 389 823 1249 509 1620
1500 525 1050 1575 750 2250
89 47 88 83 53 94
73 98 59 61
16042 16050
1 x 70 mm² 3 x 70 mm²
15,4 27,1
722 2217
1050 3150
62 108
73
16043 16051 16044 16052
1 x 95 mm² 3 x 95 mm² 1 x 120 mm² 3 x 120 mm²
17,5 31,3 19,5 34,7
986 3073 1248 3874
1425 4275 1800 5400
70 125 78 139
83 87
Art. Number TKF
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 7
Marine and Offshore MarineLine YZp 0,6/1 kV
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
16045 16053
1 x 150 mm² 3 x 150 mm²
21,5 37,9
1503 4756
2250 6750
86 152
90
16046 16054
1 x 185 mm² 3 x 185 mm²
24 41
1881 5851
2775 8325
96 164
90
16047 16055
1 x 240 mm² 3 x 240 mm²
27 47,6
2471 7636
3600 10800
108 190
90
Art. Number TKF
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 8
Marine and Offshore MarineLine YOZp 0,6/1 kV
Marine Cable 0,6/1kV, type CS85 MBZH halogen free cable . These low voltage cables are designed for power and light applications on board of vessels to international standards. Type approvals from various international maritime certification authorities are available. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine YOZp 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Article dependant, see detail sheet Core insulation XLPE Core identification HD 308 S2 Binder/filler Polyester tape Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Black Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Art. Number TKF 16110 16111 16112 16113 16114 16115 16116 16117 16118 16119 16120 16121 16122 16159 16123 16124 16125
Unit
kV kV V °C °C °C
Construction 1 x 1,5 mm² 2 x 1,5 mm² 3 x 1,5 mm² 4 x 1,5 mm² 5 x 1,5 mm² 6 x 1,5 mm² 7 x 1,5 mm² 8 x 1,5 mm² 10 x 1,5 mm² 12 x 1,5 mm² 16 x 1,5 mm² 19 x 1,5 mm² 24 x 1,5 mm² 27 x 1,5 mm²
Outer diameter (mm) 5,8 9 9,4 10,2 11,2 12,1 12,1 13,9 15,6 16,1 18,1 19 21,5 22,6
Net weight (kg/km) 59 110 130 157 191 220 231 313 397 397 504 571 739 782
Tensile load (N) 23 45 68 90 113 135 158 180 225 270 360 428 540 608
Bending radius after installation (mm) 23 36 38 41 45 48 48 56 62 64 72 76 86 90
1 x 2,5 mm² 2 x 2,5 mm² 3 x 2,5 mm²
6,2 9,9 10,4
70 137 168
38 75 113
25 40 42
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Capacity (nF/km) 55 37 37 37 63 42
Page 9
Marine and Offshore MarineLine YOZp 0,6/1 kV
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
16126
4 x 2,5 mm²
11,4
208
150
46
44
16127 16128
5 x 2,5 mm² 7 x 2,5 mm²
12,4 14
292 351
188 263
50 56
44 -
16129 16130
1 x 4 mm² 2 x 4 mm²
6,8 11,1
92 185
60 120
27 44
68
16131 16132 16133 16134
3 x 4 mm² 4 x 4 mm² 1 x 6 mm² 2 x 6 mm²
11,7 12,7 7,3 12,5
231 288 117 234
180 240 90 180
47 51 29 50
45 47 72
16135 16136
3 x 6 mm² 4 x 6 mm²
13,2 14,7
303 421
270 360
53 59
48 50
16137 16138 16139 16140 16141 16142
1 x 10 mm² 2 x 10 mm² 3 x 10 mm² 4 x 10 mm² 1 x 16 mm² 2 x 16 mm²
8,1 14,3 15,1 16,7 9,3 16,6
172 368 473 611 229 509
150 300 450 600 240 480
32 57 60 67 37 66
82 55 59 92
16143 16144
3 x 16 mm² 4 x 16 mm²
17,5 19,3
680 874
720 960
70 77
61 68
16145 16146 16147 16148
1 x 25 mm² 2 x 25 mm² 3 x 25 mm² 4 x 25 mm²
11,2 20,1 21,3 23,6
342 747 1143 1304
375 750 1125 1500
45 80 85 94
95 65 73
16158 16157 16149
1 x 35 mm² 2 x 35 mm² 3 x 35 mm²
13,1 23,3 21,4
478 989 1391
525 1050 1575
52 93 86
98 59
16401 16150 16402 16151
1 x 50 mm² 3 x 50 mm² 1 x 70 mm² 3 x 70 mm²
14,8 23,7 16,9 27,8
615 1779 852 2421
750 2250 1050 3150
59 95 68 111
61 73
16403 16152
1 x 95 mm² 3 x 95 mm²
18,9 31,9
1122 3303
1425 4275
76 128
83
16404 16153 16405 16154
1 x 120 mm² 3 x 120 mm² 1 x 150 mm² 3 x 150 mm²
20,9 34,7 23 39,5
1400 4209 1682 5140
1800 5400 2250 6750
84 139 92 158
87 90
16406 16155
1 x 185 mm² 3 x 185 mm²
25,5 42,4
2079 6272
2775 8325
102 170
90
Art. Number TKF
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 10
Marine and Offshore MarineLine YOZp 0,6/1 kV
Art. Number TKF 16407 16156
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
1 x 240 mm² 3 x 240 mm²
28,5 49,2
2691 8160
3600 10800
114 197
90
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 11
Marine and Offshore MarineLine+ YZp 0,6/1 kV
Marine Cable 0,6/1kV, type CS85 MBZH halogen free cable . These low voltage cables are designed for power and light applications on board of vessels to international standards. Type approvals from various international maritime certification authorities are available. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine+ YZp 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation XLPE Core identification HD 308 S2 Binder/filler FRNC filler Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Black Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70 Specification See appendix
Unit
kV kV V °C °C °C
Construction 2 x 1,5 mm² 3 x 1,5 mm² 4 x 1,5 mm² 5 x 1,5 mm²
Outer diameter (mm) 9 9 9,7 10,7
Net weight (kg/km) 120 125 143 176
Tensile load (N) 45 68 90 113
Bending radius after installation (mm) 36 36 39 43
16064 16065 16066
2 x 2,5 mm² 3 x 2,5 mm² 4 x 2,5 mm²
9,4 10,2 11,2
139 170 204
75 113 150
38 41 45
63 42 44
16067 16068 16069
5 x 2,5 mm² 2 x 4 mm² 3 x 4 mm²
12,5 10,8 11,8
253 195 241
188 120 180
50 43 47
44 68 45
16070 16071 16072 16073
4 x 4 mm² 2 x 6 mm² 3 x 6 mm² 4 x 6 mm²
12,8 12,2 12,8 14
291 270 321 392
240 180 270 360
51 49 51 56
47 72 48 50
Art. Number TKF 16060 16061 16062 16063
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Capacity (nF/km) 55 37 37 37
Page 12
Marine and Offshore MarineLine+ YZp 0,6/1 kV
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
16074 16075 16076
2 x 10 mm² 3 x 10 mm² 4 x 10 mm²
13,9 14,8 16,1
385 478 592
300 450 600
56 59 64
82 55 59
16077 16078 16079
2 x 16 mm² 3 x 16 mm² 4 x 16 mm²
16,2 17,1 18,4
561 698 854
480 720 960
65 68 74
92 61 68
16080 16081 16082
2 x 25 mm² 3 x 25 mm² 4 x 25 mm²
20,1 21 23,2
867 1055 1336
750 1125 1500
80 84 93
95 65 73
Art. Number TKF
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 13
Marine and Offshore MarineLine+ YOZp 0,6/1 kV
Marine Cable 0,6/1kV, type CS85 MBZH halogen free cable . These low voltage cables are designed for power and light applications on board of vessels to international standards. Type approvals from various international maritime certification authorities are available. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine+ YOZp 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation XLPE Core identification HD 308 S2 Binder/filler FRNC filler Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Black Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Unit
kV kV V °C °C °C
Construction 2 x 1,5 mm² 3 x 1,5 mm² 4 x 1,5 mm² 5 x 1,5 mm²
Outer diameter (mm) 10,7 11,4 12,1 12,9
Net weight (kg/km) 192 216 242 275
Tensile load (N) 45 68 90 113
Bending radius after installation (mm) 43 46 48 52
16164 16165 16166
2 x 2,5 mm² 3 x 2,5 mm² 4 x 2,5 mm²
11,8 12,3 13,9
238 264 347
75 113 150
47 49 56
63 42 44
16167 16168 16169
5 x 2,5 mm² 2 x 4 mm² 3 x 4 mm²
14,9 12,8 14,1
391 289 372
188 120 180
60 51 56
44 68 45
16170 16171 16172 16173
4 x 4 mm² 2 x 6 mm² 3 x 6 mm² 4 x 6 mm²
15,1 14,7 15,4 16,7
433 408 475 564
240 180 270 360
60 59 62 67
47 72 48 50
Art. Number TKF 16160 16161 16162 16163
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Capacity (nF/km) 55 37 37 37
Page 14
Marine and Offshore MarineLine+ YOZp 0,6/1 kV
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
16174 16175 16176
2 x 10 mm² 3 x 10 mm² 4 x 10 mm²
16,2 17,2 18,5
541 641 774
300 450 600
65 69 74
82 55 59
16177 16178 16179
2 x 16 mm² 3 x 16 mm² 4 x 16 mm²
18,4 19,5 21,2
736 886 1084
480 720 960
74 78 85
92 61 68
16180 16181 16182
2 x 25 mm² 3 x 25 mm² 4 x 25 mm²
22,1 23,3 25,5
1059 1285 1581
750 1125 1500
88 93 102
95 65 73
Art. Number TKF
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 15
Marine and Offshore MarineFlex YZp 0,6/1 kV
Marine Cable 0,6/1kV, type CS85 MBZH halogen free cable . These low voltage cables are designed for power and light applications on board of vessels to international standards. Type approvals from various international maritime certification authorities are available. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineFlex YZp 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 5 = Flexible Shape of conductor Round Core insulation XLPE Core identification HD 308 S2 Binder/filler FRNC filler Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Black Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70 Specification See appendix
Art. Number TKF 16090 16091 16092 16093 16094 16095 16096 16097 16098 16099 16100 16101 16102 16103 16104 16105 16106
Construction 1 x 35 mm² 2 x 35 mm² 3 x 35 mm² 1 x 50 mm² 3 x 50 mm² 1 x 70 mm² 3 x 70 mm² 1 x 95 mm² 3 x 95 mm² 1 x 120 mm² 3 x 120 mm² 1 x 150 mm² 3 x 150 mm² 1 x 185 mm² 3 x 185 mm² 1 x 240 mm² 3 x 240 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 11,9 23,3 25,8 13,4 29,4 15,6 34,3 17,4 38,2 19,4 42,6 21,4 47,4 26,6 58,4 30,2 65,9
Net weight (kg/km) 368 1124 1389 490 1855 687 2596 892 3333 1134 4227 1407 5265 1708 6379 2286 8458
Tensile load (N) 525 1050 1575 750 2250 1050 3150 1425 4275 1800 5400 2250 6750 2775 8325 3600 10800
Subject to technical alterations
Unit
kV kV V °C °C °C
Bending radius after installation (mm) 48 93 103 54 118 62 137 70 153 78 170 86 190 106 234 121 264
Capacity (nF/km) 98 59 61 73 83 87 90 90 90
Page 16
Marine and Offshore MarineFlex YOZp 0,6/1 kV
Marine Cable 0,6/1kV, type CS85 MBZH halogen free cable . These low voltage cables are designed for power and light applications on board of vessels to international standards. Type approvals from various international maritime certification authorities are available. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineFlex YOZp 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 5 = Flexible Shape of conductor Round Core insulation XLPE Core identification HD 308 S2 Binder/filler Article dependant, see detail sheet Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Black Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Art. Number TKF 16190 16191 16192 16193 16194 16195 16196 16197 16198 16199 16200 16201 16202 16203 16204 16205 16206 16207
Construction 1 x 35 mm² 3 x 35 mm² 4 x 35 mm² 1 x 50 mm² 3 x 50 mm² 4 x 50 mm² 1 x 70 mm² 3 x 70 mm² 4 x 70 mm² 1 x 95 mm² 3 x 95 mm² 4 x 95 mm² 1 x 120 mm² 3 x 120 mm² 1 x 150 mm² 3 x 150 mm² 1 x 185 mm² 3 x 185 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 13,2 26,9 29,6 14,9 30,7 34,2 17,1 36 39,6 18,7 39,7 43,8 20,7 43,9 23 49,1 28,1 60,1
Net weight (kg/km) 457 1645 2025 604 2265 2742 817 3123 3824 1029 3898 6424 1274 4881 1586 6123 1893 7131
Tensile load (N) 525 1575 2100 750 2250 3000 1050 3150 4200 1425 4275 5700 1800 5400 2250 6750 2775 8325
Subject to technical alterations
Unit
kV kV V °C °C °C
Bending radius after installation (mm) 53 108 118 60 123 137 68 144 158 75 159 175 83 176 92 196 112 240
Capacity (nF/km) 59 68 61 70 73 79 83 86 87 90 90
Page 17
Marine and Offshore MarineFlex YOZp 0,6/1 kV
Art. Number TKF 16208 16209
Construction
Outer diameter (mm)
Net weight (kg/km)
Tensile load (N)
Bending radius after installation (mm)
Capacity (nF/km)
1 x 240 mm² 3 x 240 mm²
31,5 67,4
2507 9410
3600 10800
126 270
90
Copyright (c) TKF, 24-03-2009
Subject to technical alterations
Page 18
Marine and Offshore MarineLine YZp FR 0,6/1 kV
Marine Cables designed for power and light applications (0,6/1kV). The fireresistant cables are produced in accordance with IEC 60331 as well as the flame test requirement for bunched cables acc. to IEC 60332-3 cat. A. All cables materials are halogens free, and fully wrapped with mica tape. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine YZp FR 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation Mica + XLPE Core identification HD 308 S2 Binder/filler Polyester tape Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Article dependant, see detail sheet Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Outer diameter Partnumber approx. manufacturer Construction (mm) 16350 2 x 1,5 mm² 8,5 16351 3 x 1,5 mm² 8,9 16352 4 x 1,5 mm² 9,7 16353 5 x 1,5 mm² 10,6 16354 7 x 1,5 mm² 11,8 16355 12 x 1,5 mm² 15,7 16450 27 x 1,5 mm² 22,6 16356 2 x 2,5 mm² 9,7 16358 2 x 2,5 mm² 9,7 16357 3 x 2,5 mm² 10,2 16359 3 x 4 mm² 11,3 16360 4 x 4 mm² 12,4 16361 2 x 6 mm² 12,8 16362 3 x 6 mm² 13,5 16363 4 x 6 mm² 15,1 16364 2 x 16 mm² 15,8 16365 2 x 25 mm² 19,7 16366 3 x 25 mm² 20,9
Copyright (c) TKF, 24-03-2009
Net weight 76 97 122 147 190 312 665 102 127 132 183 232 188 254 332 384 502 753
Tensile load (N) 45 68 90 113 158 270 608 75 75 113 180 240 180 270 360 480 750 1125
Bending radius after installation (mm) 34 36 39 42 47 63 90 39 39 41 45 50 51 54 60 63 79 84
Subject to technical alterations
Unit
kV kV V °C °C °C
Conductor DC resistance @ 20 12,1 12,1 12,1 12,1 12,1 12,1 12,1 7,41 7,41 7,41 4,61 4,61 3,08 3,08 3,08 1,15 0,727 0,727
Induction (mH/km) 0,307 0,307 0,307 0,307 0,307 0,307 0,307 0,279 0,279 0,279 0,278 0,278 0,259 0,259 0,259 0,227 0,223 0,223
Capacity (nF/km) 55 37 37 37 63 63 42 45 47 72 48 50 92 95 65
Page 19
Marine and Offshore MarineLine YOZp FR 0,6/1 kV
Marine Cables are designed for power and light applications (0,6/1kV). The fireresistant cables are produced in accordance with IEC 60331 as well as the flame test requirement for bunched cables acc. to IEC 60332-3. All cables materials are halogens free, and fully wrapped with mica tape Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine YOZp FR 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation Mica + XLPE Core identification HD 308 S2 Binder/filler Polyester tape Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Article dependant, see detail sheet Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Outer diameter Partnumber approx. manufacturer Construction (mm) 16382 2 x 1,5 mm² 9,4 16383 3 x 1,5 mm² 9,8 16384 4 x 1,5 mm² 10,6 16385 5 x 1,5 mm² 11,7 16386 7 x 1,5 mm² 12,6 16451 27 x 1,5 mm² 23,8 16387 2 x 2,5 mm² 10,5 16388 3 x 2,5 mm² 11,2 16389 2 x 4 mm² 11,5 16390 3 x 4 mm² 12,6 16391 4 x 4 mm² 13,8 16408 3 x 16 mm² 18,2
Copyright (c) TKF, 24-03-2009
Net weight 124 145 165 201 246 827 81 43 185 262 326 666
Tensile load (N) 45 68 90 113 158 608 75 113 120 180 240 720
Bending radius after installation (mm) 38 39 42 47 50 95 42 45 46 50 55 73
Subject to technical alterations
Unit
kV kV V °C °C °C
Conductor DC resistance @ 20 12,1 12,1 12,1 12,1 12,1 12,1 7,41 7,41 4,61 4,61 4,61 1,15
Induction (mH/km) 0,307 0,307 0,307 0,307 0,307 0,307 0,279 0,279 0,278 0,278 0,278 0,227
Capacity (nF/km) 55 37 37 37 63 42 68 45 47 61
Page 20
Marine and Offshore MarineLine+ YZp FR 0,6/1 kV
Marine Cables designed for power and light applications (0,6/1kV). The fireresistant cables are produced in accordance with IEC 60331 as well as the flame test requirement for bunched cables acc. to IEC 60332-3 cat. A. All cables materials are halogens free, and fully wrapped with mica tape. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine+ YZp FR 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation Mica + XLPE Core identification HD 308 S2 Binder/filler FRNC filler Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Article dependant, see detail sheet Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Partnumber manufacturer 16367 16368 16369 16370 16371 16372 16373 16374 16375 16376 16377 16378 16379 16380 16381
Construction 2 x 1,5 mm² 3 x 1,5 mm² 4 x 1,5 mm² 5 x 1,5 mm² 2 x 2,5 mm² 3 x 2,5 mm² 2 x 4 mm² 3 x 4 mm² 4 x 4 mm² 2 x 6 mm² 3 x 6 mm² 4 x 6 mm² 2 x 16 mm² 2 x 25 mm² 3 x 25 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter approx. (mm) 9,4 9,4 10,2 11,5 10,1 11,1 11,4 12,2 13,3 13,6 14,5 15,6 17,1 20,9 22,3
Net weight 129 135 154 195 154 192 209 254 305 299 352 417 574 772 1138
Tensile load (N) 45 68 90 113 75 113 120 180 240 180 270 360 480 750 1125
Bending radius after installation (mm) 38 38 41 46 40 44 46 49 53 54 58 62 68 84 89
Subject to technical alterations
Unit
kV kV V °C °C °C
Conductor DC resistance @ 20 12,1 12,1 12,1 12,1 7,41 7,41 4,61 4,61 4,61 3,08 3,08 3,08 1,15 0,727 0,727
Induction (mH/km) 0,307 0,307 0,307 0,307 0,279 0,279 0,278 0,278 0,278 0,259 0,259 0,259 0,227 0,223 0,223
Capacity (nF/km) 55 37 37 37 63 42 68 45 47 72 48 50 92 95 65
Page 21
Marine and Offshore MarineLine+ YOZp FR 0,6/1 kV
Marine Cables are designed for power and light applications (0,6/1kV). The fireresistant cables are produced in accordance with IEC 60331 as well as the flame test requirement for bunched cables acc. to IEC 60332-3. All cables materials are halogens free, and fully wrapped with mica tape. Characteristics
Properties Product group Low voltage marine cables Series Twenkashipkabel Type MarineLine+ YOZp FR 0,6/1 kV Standardization IEC 60092-350/-351/-353 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation Mica + XLPE Core identification HD 308 S2 Binder/filler FRNC filler Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Green Nominal voltage U0 0.6 Nominal voltage U 1 Test voltage 3500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Partnumber manufacturer 16392 16393 16394 16395 16396 16397 16398 16399 16400
Construction 2 x 1,5 mm² 3 x 1,5 mm² 4 x 1,5 mm² 5 x 1,5 mm² 2 x 2,5 mm² 3 x 2,5 mm² 2 x 4 mm² 3 x 4 mm² 4 x 4 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter approx. (mm) 11,3 11,8 12,6 13,5 12,5 13,1 13,2 14,5 15,5
Net weight 208 228 256 291 257 284 300 387 449
Tensile load (N) 45 68 90 113 75 113 120 180 240
Bending radius after installation (mm) 45 47 50 54 50 52 53 58 62
Subject to technical alterations
Unit
kV kV V °C °C °C
Conductor DC resistance @ 20 12,1 12,1 12,1 12,1 7,41 7,41 4,61 4,61 4,61
Induction (mH/km) 0,307 0,307 0,307 0,307 0,279 0,279 0,278 0,278 0,278
Capacity (nF/km) 55 37 37 37 63 42 68 45 47
Page 22
Marine and Offshore MarineCom YOZc 250 V
Cables designed for control, instrumentation, tele- and data-communication up to 250V. The most striking cable features: low Electric Magnetic Interference (EMI), good cross talk attenuation, minimal signal loss. The halogen-free outer sheath is flame-retardent and has good chemical Characteristics
Art. Number TKF 16271 16272 16273 16270 16274 16275 16276 16277 16278 16279 16280 16283 16281 16282
Properties Product group Communication marine cables Series Twenkashipkabel Type MarineCom YOZc 250 V Standardization IEC 60092-350/-351/-376 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor category Class 2 = Stranded Stranding element Pair Core insulation XLPE Core identification Numbers Binder/filler Polyester tape Collective screen Braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Grey Diameter conductor 1.11 Nominal cross section conductor 0.75 Number of cores Article dependant, see detail sheet Outer diameter approx. Article dependant, see detail sheet Installation temperature -20 / 70 Operating temperature -40 / 70
Construction 1 x 2 x 0,75 mm² 1 x 3 x 0,75 mm² 1 x 4 x 0,75 mm² 2 x 2 x 0,75 mm² 4 x 2 x 0,75 mm² 6 x 2 x 0,75 mm² 7 x 2 x 0,75 mm² 10 x 2 x 0,75 mm² 14 x 2 x 0,75 mm² 19 x 2 x 0,75 mm² 24 x 2 x 0,75 mm² 27 x 2 x 0,75 mm² 30 x 2 x 0,75 mm² 37 x 2 x 0,75 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 7,1 7,5 8 10,3 12 14,3 14,3 17,2 19,3 22,2 24,6 25,8 27 30,1
Net weight (kg/km) 74 84 103 125 185 269 271 365 471 624 762 823 912 1153
Tensile load (N) 23 34 45 45 90 135 158 225 315 428 540 608 675 833
Bending radius after installation (mm) 28 30 32 41 48 57 57 69 77 89 98 103 108 120
Subject to technical alterations
Unit
mm mm² mm °C °C
Conductor DC resistance @ 20 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5
Induction (mH/km) 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331
Capacity (µF/Km) 55 55 55 55 55 55 55 55 55 55 55 55 55 55
Page 23
Marine and Offshore Marine2Com YOZ2c 250 V
Designed for control, instrumentation, tele- and data-communication up to 250V. Cable features as MarineCom plus each pair and overall electrically shielded. Characteristics
Art. Number TKF 16290 16291 16292 16293 16294 16295 16296 16297 16298 16299
Properties Product group Communication marine cables Series Twenkashipkabel Type Marine2Com YOZ2c 250 V Standardization IEC 60092-350/-351/-376 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor category Class 2 = Stranded Stranding element Pair Core insulation XLPE Core identification Numbers Binder/filler Polyester tape Screen over stranding element Alpet tape Collective screen Foil + braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Grey Diameter conductor 1.11 Nominal cross section conductor 0.75 Number of cores Article dependant, see detail sheet Outer diameter approx. Article dependant, see detail sheet Installation temperature -20 / 70 Operating temperature -40 / 70
Construction 2 x 2 x 0,75 mm² 4 x 2 x 0,75 mm² 6 x 2 x 0,75 mm² 7 x 2 x 0,75 mm² 10 x 2 x 0,75 mm² 14 x 2 x 0,75 mm² 19 x 2 x 0,75 mm² 24 x 2 x 0,75 mm² 30 x 2 x 0,75 mm² 37 x 2 x 0,75 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 11,2 12,8 15,3 15,3 18,5 20,7 23,9 26,5 29,3 32,5
Net weight (kg/km) 161 230 329 335 460 590 782 956 1151 1437
Tensile load (N) 45 90 135 158 225 315 428 540 675 833
Bending radius after installation (mm) 45 51 61 61 74 83 96 106 117 130
Subject to technical alterations
Unit
mm mm² mm °C °C
Conductor DC resistance @ 20 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5
Induction (mH/km) 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331
Capacity (µF/Km) 80 80 80 80 80 80 80 80 80 80
Page 24
Marine and Offshore MarineSignal YZs 250 V
Halogen-free Cables designed for signal, control and alarm applications up to 250 V. The halogen-free outer sheath is flame-retardant and has good chemical resistance. Characteristics
Properties Product group Signal marine cables Series Twenkashipkabel Type MarineSignal YZs 250 V Standardization IEC 60092-350/-351/-376 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation XLPE Core identification Numbers Binder/filler Polyester tape Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Grey Nominal voltage U 0.25 Test voltage 1500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Art. Number TKF 16210 16211 16212 16213 16214 16215 16216 16217 16218 16220 16221 16222 16223 16224 16225 16226 16227 16228
Construction 2 x 0,75 mm² 3 x 0,75 mm² 4 x 0,75 mm² 5 x 0,75 mm² 7 x 0,75 mm² 12 x 0,75 mm² 19 x 0,75 mm² 27 x 0,75 mm² 37 x 0,75 mm² 2 x 1 mm² 3 x 1 mm² 4 x 1 mm² 5 x 1 mm² 7 x 1 mm² 12 x 1 mm² 19 x 1 mm² 27 x 1 mm² 37 x 1 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 6,3 6,6 7,1 7,7 8,6 11,2 13,5 15,8 18,2 6,7 7 7,6 8,5 9,2 12,1 14,8 17,3 20
Net weight (kg/km) 44 54 65 80 102 165 240 332 443 50 62 76 97 120 195 294 406 542
Tensile load (kN) 23 34 45 56 79 135 214 304 416 30 45 60 75 105 180 285 405 555
Bending radius after installation (mm) 25 26 28 31 34 45 54 63 73 27 28 30 34 37 48 59 69 80
Subject to technical alterations
Unit
kV V °C °C °C
Conductor DC resistance @ 20 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1
Induction (mH/km) 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,332 0,332 0,332 0,332 0,332 0,332 0,332 0,332 0,332
Capacity (nF/km) 80 130 135 140 150 150 150 150 150 95 140 145 150 160 160 160 160 160
Page 25
Marine and Offshore MarineSignal YOZs 250 V
Cables designed for signal, control and alarm applications up to 250 V. The halogenfree outer sheath is flame-retardent and has good chemical resistance. The copper wire braiding reduces EMI and extra mechanical protection. Characteristics
Properties Product group Signal marine cables Series Twenkashipkabel Type MarineSignal YOZs 250 V Standardization IEC 60092-350/-351/-376 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation XLPE Core identification Numbers Binder/filler Polyester tape Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Grey Nominal voltage U 0.25 Test voltage 1500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Art. Number TKF 16241 16242 16243 16244 16245 16246 16247 16248 16249 16250 16251 16252 16253 16254 16255 16256 16257 16258
Construction 2 x 0,75 mm² 3 x 0,75 mm² 4 x 0,75 mm² 5 x 0,75 mm² 7 x 0,75 mm² 12 x 0,75 mm² 19 x 0,75 mm² 27 x 0,75 mm² 37 x 0,75 mm² 2 x 1 mm² 3 x 1 mm² 4 x 1 mm² 5 x 1 mm² 7 x 1 mm² 12 x 1 mm² 19 x 1 mm² 27 x 1 mm² 37 x 1 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 7,2 7,5 8 8,8 9,5 12,1 14,8 17,1 19,5 7,6 7,9 8,7 9,4 10,1 13 15,9 18,4 21,1
Net weight (kg/km) 74 84 103 120 140 217 338 432 565 81 100 118 135 165 255 386 517 675
Tensile load (kN) 23 34 45 56 79 135 214 304 416 30 45 60 75 105 180 285 405 555
Bending radius after installation (mm) 29 30 32 35 38 48 59 68 78 30 32 35 38 40 52 64 74 84
Subject to technical alterations
Unit
kV V °C °C °C
Conductor DC resistance @ 20 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1
Induction (mH/km) 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,331 0,332 0,332 0,332 0,332 0,332 0,332 0,332 0,332 0,332
Capacity (nF/km) 80 130 135 140 150 150 150 150 150 95 140 145 150 160 160 160 160 160
Page 26
Marine and Offshore MarineSignal+ YZs 250 V
Halogen-free Cables designed for signal, control and alarm applications up to 250 V. The halogen-free outer sheath is flame-retardant and has good chemical resistance. Characteristics
Properties Product group Signal marine cables Series Twenkashipkabel Type MarineSignal+ YZs 250 V Standardization IEC 60092-350/-351/-376 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation XLPE Core identification Numbers Binder/filler FRNC filler Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Grey Nominal voltage U 0.25 Test voltage 1500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Art. Number TKF 16231 16232 16233 16234 16235 16236 16237 16238
Construction 2 x 0,75 mm² 3 x 0,75 mm² 4 x 0,75 mm² 5 x 0,75 mm² 2 x 1 mm² 3 x 1 mm² 4 x 1 mm² 5 x 1 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 6,7 7 7,5 8,2 7,3 7,5 8,2 8,9
Net weight (kg/km) 64 72 84 100 78 86 100 120
Tensile load (kN) 23 34 45 56 30 45 60 75
Bending radius after installation (mm) 27 28 30 33 29 30 33 36
Subject to technical alterations
Unit
kV V °C °C °C
Conductor DC resistance @ 20 24,5 24,5 24,5 24,5 18,1 18,1 18,1 18,1
Induction (mH/km) 0,331 0,331 0,331 0,331 0,332 0,332 0,332 0,332
Capacity (nF/km) 80 130 135 140 95 140 145 150
Page 27
Marine and Offshore MarineSignal+ YOZs 250 V
Cables designed for signal, control and alarm applications up to 250 V. The halogenfree outer sheath is flame-retardent and has good chemical resistance. The copper wire braiding reduces EMI and extra mechanical protection. Characteristics
Properties Product group Signal marine cables Series Twenkashipkabel Type MarineSignal+ YOZs 250 V Standardization IEC 60092-350/-351/-376 Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A Conductor material Cu Standardization conductor material IEC 60228 Conductor category Class 2 = Stranded Shape of conductor Round Core insulation XLPE Core identification Numbers Binder/filler FRNC filler Construction outer shield Tinned copper braiding Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Colour outer sheath Grey Nominal voltage U 0.25 Test voltage 1500 Maximum conductor temperature 90 Installation temperature -20 / 70 Operating temperature -40 / 70
Art. Number TKF 16261 16262 16263 16264 16265 16266 16267 16268
Construction 2 x 0,75 mm² 3 x 0,75 mm² 4 x 0,75 mm² 5 x 0,75 mm² 2 x 1 mm² 3 x 1 mm² 4 x 1 mm² 5 x 1 mm²
Copyright (c) TKF, 24-03-2009
Outer diameter (mm) 8 8,5 9,1 9,7 8,6 9 9,6 10,2
Net weight (kg/km) 111 122 137 159 125 168 158 175
Tensile load (kN) 23 34 45 56 30 45 60 75
Bending radius after installation (mm) 32 34 36 39 34 36 38 41
Subject to technical alterations
Unit
kV V °C °C °C
Conductor DC resistance @ 20 24,5 24,5 24,5 24,5 18,1 18,1 18,1 18,1
Induction (mH/km) 0,331 0,331 0,331 0,331 0,332 0,332 0,332 0,332
Capacity (nF/km) 80 130 135 140 95 140 145 150
Page 28
Marine and Offshore MarinePower YOZmv 6/10 kV
Medium voltage cables designed for electric power transport between engine room generator end electrical machines. Characteristics
Art. Number TKF 33100 33101 33102 33103 33104 33105 33106 33107 33108 33109 33110 33111 33112 33117
Properties Product group Series Twenkashipkabel Type MarinePower YOZmv 6/10 kV Standardization IEC 60092-354 Number of cores Article dependant, see detail sheet Nominal cross section conductor Article dependant, see detail sheet Conductor material Cu Conductor category Class 2 ss = stranded flexible Conductor shield Semiconductive XLPE Core insulation XLPE Material outer sheath Flame Retardant Halogen Free Polyolefin Compound Halogen free IEC 60754-1 Outer diameter approx. Article dependant, see detail sheet Nominal voltage U0 6 Nominal voltage U 10
Construction 1 x 35 mm² 1 x 50 mm² 1 x 70 mm² 1 x 95 mm² 1 x 120 mm² 1 x 150 mm² 1 x 185 mm² 1 x 240 mm² 3 x 35 mm² 3 x 50 mm² 3 x 70 mm² 3 x 95 mm² 3 x 120 mm² 3 x 25 mm²
Copyright (c) TKF, 24-03-2009
Bending radius after installation (m) 0,288 0,312 0,344 0,38 0,414 0,444 0,478 0,528 0,544 0,59 0,634 0,695 0,758 0,512
Bending radius during installation (m) 0,3446 0,3734 0,4118 0,455 0,4958 0,5318 0,5726 0,6326 0,6518 0,707 0,7598 0,833 0,9086 0,6134
Net weight 755 955 1159 1442 1674 2086 2413 2996 3143 3821 4698 5677 6651 2755
Subject to technical alterations
Tensile load (N) 1750 2500 3500 4750 6000 7500 9250 12000 5250 7500 10500 14250 18000 3750
Unit
mm²
mm kV kV
Outer diameter approx. (mm) 21,2 22,5 24,1 26 27,8 29,3 31,1 33,7 46,8 50,3 53,1 57,5 62,2 44,7
Page 29
Marine Cables
Current ratings Current ratings1) in continious service for single- and multi-core cables (according to IEC 60092-352/Ambient temperature 45 °C) Nominal CrossCurrent rating (A) sectional area (mm2 ) Number of cores loaded 1 2 1 16 14 1.5 20 17 2.5 28 24 4 38 32 6 48 41 10 67 57 16 90 77 25 120 102 35 145 123 50 180 153 70 225 191 95 275 234 120 320 272 150 365 310 185 415 353 240 490 417
3 and 4 11 14 20 27 34 47 63 84 102 126 158 193 224 256 291 343
1)
Current ratings are dictated by installation circumstances, so the reduction factors of IEC 60092-352 should be taken into account.
Correction factors for various ambient air temperatures Maximum conductor temperature 85°C
Version: 8-11-2005
35°C 1.12
Correction factors for ambient air temperature of 40°C 45°C 50°C 55°C 60°C 65°C 70°C 1.06 1.00 1.94 0.87 0.79 0.71 0.61
Subject to technical alterations
BV Twentsche Kabelfabriek Spinnerstraat 15 - P.O. Box 6 - 7480 AA – Haaksbergen – The Netherlands Tel: +31 53 - 573 22 55 - Fax: +31 53 - 573 21 85 -
[email protected] - www.tkf.nl
75°C 0.50
Page 1 / 2
Marine Cables
Version: 8-11-2005
Subject to technical alterations
BV Twentsche Kabelfabriek Spinnerstraat 15 - P.O. Box 6 - 7480 AA – Haaksbergen – The Netherlands Tel: +31 53 - 573 22 55 - Fax: +31 53 - 573 21 85 -
[email protected] - www.tkf.nl
Page 2 / 2
Product Information Core Colours - Aderkleuren HD308 S2-2001
Omschrijving Beschreibung Description Definition
Q Aders Adem Cores Cond. PE*
Installatiedraad - Aderleitung Building wire - Fil d’installation
N
L1/L2
L/L2
L3
L3
1 1
Laagspanningskabel zonder gr-ge Niederspannungskabel ohne gn-ge Low voltage cables without gr-ye Cables basse tension sans ve-ja
2 3 3a 4 5 >5
Laagspanningskabel met gr-ge Niederspannungskabel mit gn-ge Low voltage cables with gr-ye Cables basse tension avec ve-ja
Nr. *
3 4 4a 5 >5
Nr. *
1 Geharmoniseerde buigzame leidingen Harmonisierte Schlauchleitungen Harmonised flexible cables Cables souples harmonisés
2 3 4 5 >5 >5
Nr. * Nr. *
Notes: * PE = beschermingsleiding - Schutzleiter - protective conductor - conducteur de protection, N = nulleiding - Neutralleiter - neutral conductor - conducteur neutre, L, L1, L2, L3 = faseleidingen - Phasenleiter - phase conductors - conducteurs de phase, Nr.
= zwart genummerd - schwarz nummeriert - black numbered - noir numéroté
© BV Twentsche Kabelfabriek
Subject to technical alterations
www.tkf.nl-
More information This catalogue also contains information about product families. Information at item level can be requested via our website and from our sales staff. This catalogue has been customised. Information about products that have not been included in this catalogue is available from our sales departments and can also be found on our website www.tkf.nl.
TKF is not liable for any immediate or consequential damage of any kind that may occur as a result of this catalogue or which in any way is related to the use of this catalogue. © TKF All rights reserved. Information in this catalogue may only be distributed with acknowledgement of the source. Terms of delivery Our general terms of delivery apply to all our deliveries including the products named in the catalogue. They are available via our website www.tkf.nl or from our sales departments. Prices Please contact our sales department for price information. The gross item prices of part of our portfolio have been included in our TPL price list. It can be downloaded via our website or requested from our sales staff.
Please contact us for additional technical or commercial information. Contact information for our sales teams can be found on the next page and on our website. Subject to changes TKF reserves the right to make changes to its product specifications and its range of products without informing its clients of this in advance. Disclaimer Despite all the care and attention that has been paid to compiling this catalogue, it may contain omissions and/or errors. TKF provides the content of this catalogue in the state that it is in, without any guarantees with regard to its reliability, suitability for a certain purpose or otherwise.
© BV Twentsche Kabelfabriek
Subject to technical alterations
www.tk.nl-
Global customer service Please consult the table below for the contact information for our sales teams. The latest information about our representatives worldwide is available from our sales staff and on our website (www.tkf.nl). General / Sales support Tel. +31 (0)53 573 22 55
Fax +31 (0)53 573 23 61
[email protected]
Fax +31 (0)53 573 21 84
[email protected]
Fax +31 (0)53 573 21 84
[email protected]
Fax +31 (0)53 573 21 84
[email protected]
Fax +31 (0)53 573 29 38
[email protected]
Fax +31 (0)53 573 29 38
[email protected]
Fax +31 (0)53 573 23 06
[email protected]
Installation companies Tel. +31 (0)53 573 23 88 Trading companies Tel. +31 (0)53 573 23 69 Electricity distribution companies Tel. +31 (0)53 573 23 86 Export Industrial Tel. +31 (0)53 573 23 90 Export Broadband Tel. +31 (0)53 573 23 91 Telecom solutions Tel. +31 (0)53 573 23 89
Cable reel sizes and weights A wide range of reels with various sizes and weights is used to store and transport our cables. The most common types of rees and their sizes and weights are shown in this table. Flange diameter (F) mm
Core Central hole Largest diameter (K) diameter (A) width (B) mm mm mm
Winding width (W) mm
Empty weight kg
Volume m3
560
170
80
470
390
15
0.12
750
350
100
420
350
20
0.19
800
400
100
500
400
40
0.25
1000
500
100
620
500
65
0.49
1200
600
100
740
600
100
0.84
1500
800
100
940
750
160
1.66
1600
800
100
1030
840
225
2.07
1750
1030
100
980
750
250
2.36
1800
900
100
1030
840
285
2.62
2000
1200
100
1080
850
325
3.39
2250
1410
100
1120
830
510
4.45
2500
1500
100
1250
950
640
6.13
2500
1500
100
1520
1220
670
7.46
2650
1500
100
1520
1220
730
8.38
2800
1700
100
1500
1150
950
9.23
3000
1600
100
1600
1250
1050
11.30
A
W B
F = Diameter flange K = Diameter core A = Diameter axle-hole B = Largest width W = Winding width
Empty reel return To get your empty reels in the Netherlands collected quickly, please send your request to our shipping department via the website (www.tkf.nl) or by e-mail to
[email protected]. If reels have to be collected outside the Netherlands, please contact our sales staff. © BV Twentsche Kabelfabriek
Subject to technical alterations
www.tkf.nl-
K F
Notes
Notes
Notes
Choose TKF - Choose quality!
BV Twentsche Kabelfabriek Spinnerstraat 15 P.O. Box 6 7480 AA Haaksbergen The Netherlands Tel.: +31 (0)53 573 22 55 Fax: +31 (0)53 573 21 85 E-mail:
[email protected] Website: www.tkf.nl