2.61

201 East Broad Street Spartanburg, SC 29306

2.61

9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

FOODSERVICE EQUIPMENT SCHEDULE

P.O. Box 41099 Fredericksburg, VA 22404

7.01

8.22

8.04

8.03

9.01

POPC ORN $ 2 .0 0

7.01 6.66

9.03

1.43 2.68

9.03 2.68 2.78

POPC ORN $ 2 .0 0

6.33

9.01

8.03

8.04

6.21

1.31

8.18

8.23 6.64

1.21

2.22

1

MEGA TOP TABLE

CONTINENTAL

SW60-24M

1.43

1

SOFT SERVE MACHINE

CARPIGIANI

UF-253

1.50

1

WALK-IN COOLER/FREEZER

BALLY

CUSTOM

1.52A

1

1 HP MED-TEMP REFRIG. SYSTEM

BALLY

CUSTOM

1.52B

1

EVAPORATOR COIL

BALLY

CUSTOM

1.62A

1

1 HP LOW-TEMP REFRIG. SYSTEM

BALLY

CUSTOM

1.62B

1

EVAPORATOR COIL

BALLY

CUSTOM

2.12

1

BASE CABINET, 48"

SELECT STAINLESS

4TCD-30

2.22

2

WORK TABLE WITH PAN SLIDES, 96 X 30

SELECT STAINLESS

8SL-30/PS-T-1

2.45

1

SHELVING, 4-TIER, SEALED 21 X 24

ISS

S4146E

2.46

1

SHELVING, 4-TIER, SEALED 21 X 36

ISS

S4346E

2.47

1

SHELVING, 4-TIER, SEALED 21 X 42

ISS

S4446E

2.48

1

SHELVING, 4-TIER, SEALED 21 X 48

ISS

S4546E

4

SHELVING, 5-TIER, 21 X 60

ISS

S4857C

2.68

4

SHEET PAN RACK

NEW AGE

1635

2.76

1

DOUBLE WALL SHELF ASSEMBLY, 36"

ISS

WMT14Z/(2)1436Y

9.03

2.77

1

DOUBLE WALL SHELF ASSEMBLY, 48"

ISS

WMT14Z/(2)1448Y

9.01

2.78

1

DOUBLE WALL SHELF ASSEMBLY, 60"

ISS

(2) WMT14Z/(4)1430Y

2.82

1

CLEAN DISH TABLE

SELECT STAINLESS

4CD-R

2.83

1

SOILED DISHTABLE

SELECT STAINLESS

6SD-L-LSL/PR-DM

2.85

1

CORNER WALL SHELF WITH UTENSIL RACK, 72"

SELECT STAINLESS

CUSTOM

3.01

1

SLICER

HOBART

2912

3.09

1

GARBAGE DISPOSER, 1 1/2 HP

IN-SINK-ERATOR

SS-150

4.08

1

DOUBLE FULL SIZED CONVECTION OVEN

SOUTHBEND

GS-22SC

4.28

1

FOUR BURNER RANGE W/ CABINET BASE

SOUTHBEND

424E

9.01

4.30

1

GRIDDLE, 48"

STAR

848TS

9.03

4.34

1

CHAR-BROILER, 24"

STAR

8124RCB

4.36

1

FRYER BATTERY, TWO FRYERS AND FILTER

PITCO

SG18S/18-2UFM

4.38

2

DUMP STATION, 21"

HATCO

GRSFS-21

9.03

4.48

1

POPCORN POPPER

CRETORS

20 OZ. DIPLOMAT

9.01

6.13

2

PERISTALIC DISPENSER, DOUBLE

STAR

HPDE2H

6.21

4

SANDWICH SLIDE, 24"

HATCO

GRSDH-24

6.33

2

PRETZEL DISPLAY CABINET

HATCO

FDW-1X

6.64

4

FOOD HOLDING BINS

PRINCE CASTLE

DHB4PT-20

6.65

1

BANQUET CART, 180

FOOD WARMING EQUIP.

P-180

6.66

1

BANQUET CART, 120

FOOD WARMING EQUIP.

P-120

7.01

4

HAND SINK

SELECT STAINLESS

SHS-1-ST-SK

7.04

1

MOP SINK

SELECT STAINLESS

MS-2028-8/8-MF

9.01

7.09

1

3-COMPARTMENT CORNER SINK

SELECT STAINLESS

3BC1824-2D18

9.03

7.12

1

WORK TABLE WITH SINK, 72"

SELECT STAINLESS

6SUB-30/B1824

7.37

1

WAREWASHING MACHINE

HOBART

AM-15T-2

8.03

8

BEER DRAINER

POLAR BEER

0510-1012

9.03

8.04

8

TWO HEAD BEER DISPENSER

POLAR BEER

1201

9.01

8.18

5

SODA DISPENSER WITH ICE BIN

NIKEC

BY VENDOR

8.22

5

CARBONATOR

NIKEC

BY VENDOR

8.23

5

CUP RAIL, 24"

DISPENSE RITE

WR-CC-22

8.47

1

ICE BIN, 1300#

FOLLETT

SG-1300-48

8.53

1

ICE CUBER WITH REMOTE COND. UNIT, 1300#

HOSHIZAKI

KM-1300MWH/URC-12

POPC ORN $ 2 .0 0

8.04 8.18

8.04 POPC ORN $ 2 .0 0 POPC ORN $ 2 .0 0

6.13 8.03

8.04

1.20 8.18

8.04 POPC ORN $ 2 .0 0

6.33

POPC ORN $ 2 .0 0

2.12 7.01

8.03

8.04 8.18

8.23

1.50

1.31

2.61

4.48

2.58

DL2G-SS

9.03

8.03

2.58

SWF48FB

CONTINENTAL

S4557C

6.21

8.47

CONTINENTAL

REFRIGERATED EQUIPMENT STAND, 72"

6.13

8.22

3.01

FREEZER BASE

1

S4357C

8.23

8.53

1

ISS

6.21

7.12

1.29

ISS

4.38

2.76

1.22

SHELVING, 5-TIER, 21 X 42

8.03

6.64

CUSTOM

SHELVING, 5-TIER, 21 X 36

8.22

4.28

CUSTOM

RANDELL

1

8.23

2.22

RANDELL

REFRIGERATED SERVICE COUNTER, RIGHT

2

8.03

6.64

REFRIGERATED SERVICE COUNTER, LEFT

2.59

4.36

4.08

1

2.58

1.29

4.34

MODEL

9.01

6.21

4.30

MAKE

8.04

2.77

4.38

1

1.21

REMARKS

8.03 POPC ORN $ 2 .0 0

6.64

1.22

8.22

1.20

DESCRIPTION

8.22

1.52

9.01

8

CONCESSION P.O.S. MACHINE

NIKEC

QUEST

9.03

8

CASH DRAWER

NIKEC

INDIANA CASH DRAWER

9508 Flint Hill Court Fredericksburg, VA 22407 540/786-3663 (VOICE) 540/786-3673 (FAX)

7.01 2.68

2.47 1.52

2.59

2.68

1.62

2.61

2.48

8.53

1.62

2.45

2.46

MAIN CONCOURSE CONCESSION STAND FOODSERVICE EQUIPMENT PLAN

8.23

QTY

VISALIA, CA

8.18

ITEM

RECREATION PARK

6.65

2.47

REMOTE CONDENSING UNITS - VERIFY LOCATION

2.47

7.04

2.61

REVISION HISTORY 2.85

17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

7.09

7.37

3.09

2.82

2.83

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

FOODSERVICE EQUIPMENT PLAN

BY

JD

1/4" = 1'0"

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-1.0

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404

FOODSERVICE ELECTRICAL SCHEDULE ELECTRICAL

POPC ORN $ 2 .0 0

9.01

QTY

1.20

1

1.21

1

DESCRIPTION

REMARKS

REFRIGERATED SERVICE COUNTER, LEFT

REFRIGERATED SERVICE COUNTER, RIGHT

MAKE

MODEL

RANDELL

CUSTOM

RANDELL

KW

CUSTOM

1.43

6.66

1.21 POPC ORN $ 2 .0 0

6.33

1.31

9.01

8.22 6.21

8.18 1.21

6.64

6.13

POPC ORN $ 2 .0 0

6.64

9.01

6.21

1.22

HP

AMPS

VOLTS

PHASE

TYPE

NEMA

1/4

6.0

120

1

DR

5-15

+18"

REFRIG. COMPARTMENT

1/4

6.0

120

1

DR

5-15

+18"

REFRIG. COMPARTMENT

1/4

5.0

120

1

DR

5-15

+18"

REFRIG. COLD PAN

1/4

6.0

120

1

DR

5-15

+18"

REFRIG. COMPARTMENT

1/4

6.0

120

1

DR

5-15

+18"

REFRIG. COMPARTMENT REFRIG. COLD PAN

1/4

5.0

120

1

DR

5-15

+18"

1.22

1

FREEZER BASE

CONTINENTAL

SWF48FB

1/3

7.9

120

1

DR

5-15

+18"

1.29

1

REFRIGERATED EQUIPMENT STAND, 72"

CONTINENTAL

DL2G-SS

1/3

6.9

120

1

DR

5-15

+18"

1.31

1

MEGA TOP TABLE

CONTINENTAL

SW60-24M

1/4

8.2

120

1

DR

5-15

+18"

1.43

1

SOFT SERVE MACHINE

CARPIGIANI

UF-253

7

36.0

208

1

J-BOX

DIRECT

+60"

1.50

1

WALK-IN COOLER/FREEZER

BALLY

CUSTOM

120

1

J-BOX

DIRECT

DN +102" COOLER LIGHTS

120

1

J-BOX

DIRECT

DN +102" FREEZER LIGHTS

208

3

J-BOX

DIRECT

208

1

J-BOX

DIRECT

1.52A

1

1 HP MED-TEMP REFRIG. SYSTEM

BALLY

CUSTOM

1.52B

1

EVAPORATOR COIL

BALLY

CUSTOM

1.62A

1

1 HP LOW-TEMP REFRIG. SYSTEM

BALLY

CUSTOM

1.62B

1

EVAPORATOR COIL

BALLY

CUSTOM

3.01

1

SLICER

HOBART

2912

3.09

1

GARBAGE DISPOSER, 1 1/2 HP

IN-SINK-ERATOR

SS-150

4.08

1

DOUBLE FULL SIZED CONVECTION OVEN

SOUTHBEND

GS-22SC

1 1.2 1 1/2

1.21 POPC ORN $ 2 .0 0

4.36

1

FRYER BATTERY, TWO FRYERS AND FILTER

PITCO

4.36 8.22

4.36

8.18

4.36

4.38 POPC ORN $ 2 .0 0

4.08

9.01

1.20

4.08

6.64

POPC ORN $ 2 .0 0

6.64

9.01

1.20

8.18

J-BOX

DIRECT

1

J-BOX

DIRECT

VERIFY

6.0

120

1

DR

5-15

+18"

208

3

J-BOX

DIRECT

+18"

CONDENSING UNIT

DN +102" EVAPORATOR COIL

120

1

SR

5-15

+18"

15.8

120

1

SR

5-15

+18"

1.7

120

1

DR

5-15

+18"

CONTROLS

1.7

120

1

DR

5-15

+18"

CONTROLS

7

120

1

DR

5-15

+18"

FILTER

10

120

1

SR

5-15

+18"

SG18S/18-2UFM

4.38

2

DUMP STATION, 21"

HATCO

GRSFS-21

4.48

1

POPCORN POPPER

CRETORS

20 OZ. DIPLOMAT

4.2

120/208

1

SR

5-20

+18"

6.13

2

PERISTALIC DISPENSER, DOUBLE

STAR

HPDE2H

0.80

8.0

120

1

DR

5-15

+48"

6.21

4

SANDWICH SLIDE, 24"

HATCO

GRSDH-24

1.67

13.8

120

1

SR

5-15

+48"

6.33

2

PRETZEL DISPLAY CABINET

HATCO

FDW-1X

1.44

12.0

120

1

DR

5-15

+48"

6.64

4

FOOD HOLDING BINS

PRINCE CASTLE

DHB4PT-20

1.60

13.3

120

1

SR

5-15

+48"

6.65

1

BANQUET CART, 180

FOOD WARMING EQUIP.

P-180

1.60

13.3

120

1

SR

5-15

+18"

6.66

1

BANQUET CART, 120

FOOD WARMING EQUIP.

P-120

2.10

17.5

120

1

SR

5-20

+18"

7.12

1

WORK TABLE WITH SINK, 72"

SELECT STAINLESS

6SUB-30/B1824

120

1

DR

5-15

+48"

CONVENIENCE

7.37

1

WAREWASHING MACHINE

HOBART

AM-15T-2

12.0

480

3

J-BOX

DIRECT

+13"

TANK HEAT AND CONTROLS

15.6

480

3

J-BOX

DIRECT

+10"

BOOSTER HEATER

2.0

120

1

DR

5-15

+18"

7.2

120

1

DR

5-15

+18"

12.0

208

1

J-BOX

DIRECT

+ 90"

5.0

120

1

DR

8.18

5

SODA DISPENSER WITH ICE BIN

NIKEC

BY VENDOR

8.22

5

CARBONATOR

NIKEC

BY VENDOR

8.53

1

ICE CUBER WITH REMOTE COND. UNIT, 1300#

ICE CUBER

HOSHIZAKI

1.2

1/3 KM-1300MWH URC-12

8.22

6.21

3

120

15.8

6.21 6.13

208

1/2

1/3 1.29

CONDENSING UNIT

1/2

9.01

4.38

VERIFY

9.01

8

CONCESSION P.O.S. MACHINE

NIKEC

540/786-3663 (VOICE) 540/786-3673 (FAX)

DN +102" EVAPORATOR COIL

4.2 1 1/2

9508 Flint Hill Court Fredericksburg, VA 22407

CONN. HT. REMARKS

ICE CUBER POWER FROM ICE CUBER

QUEST

+18"

6.33 8.53

1.20

POPC ORN $ 2 .0 0

7.12

9.01

3.01

POPC ORN $ 2 .0 0

4.48

9.01

8.22 8.18

ELECTRICAL NOTES

ELECTRICAL SYMBOLS

Services shown relate to foodservice equipment requirements only and show only the point of connection. Convenience receptacles, switches, clock outlets, telephone and computer conduits, HVAC, lighting and other power requirements are not included in these drawings.

UP+

Electrical system is designed for 120/208 3 ph, 4 wire, 60 hz. Electrical division is responsible for: • All wiring, fittings and labor, up to and including final connections.

1.50 1.52B

• Interwiring ventilator, fire protection, waste disposal, remote refrigeration and ice cuber systems. • Provision of all exposed hardware and fixtures to be waterproof and made of chrome or other corrosion resistant material. 1.52A

• Coordination of panelboards with an appropriate diversity factor and 20% spare capacity. • Provision of shunt trip breakers for cooking equipment as required. • Provision of ground fault protector breakers or outlets as required.

1.62B

+

8.53

automatic shut-off to cooking equipment, and connection to fire alarm as required.

DISTANCE ABOVE FINISHED FLOOR

DN+

DISTANCE DOWN TO FINISHED FLOOR

BTC

BRANCH TO CONNECTION POINT(S)

V

VOLTS

PH

PHASE

A

AMPS

KW

KILOWATTS

HP

HORSEPOWER EQUIPMENT CONNECTION

• All electrical work within fabricated equipment will be by the supplier, ready for final, single point connection, unless otherwise noted. • Connection of fire suppression system to microswitch or shunt trip breaker in electrical panel to provide

1.50

STUB-UP FROM FLOOR

MAIN CONCOURSE CONCESSION STAND FOODSERVICE ELECTRICAL PLAN

8.18

ITEM

RECREATION PARK

8.22

VISALIA, CA

6.65

DUPLEX RECEPTACLE SINGLE RECEPTACLE JB

JUNCTION BOX ( CEILING MOUNTED LIGHT

SW 1.62A

SWITCH SPECIAL CONNECTION AS NOTED

REVISION HISTORY 3.09

7.37

7.37

17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

FOODSERVICE ELECTRICAL PLAN

BY

JD

1/4" = 1'0"

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-1.1

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404

7.01

FOODSERVICE PLUMBING SCHEDULE PLUMBING

8.18

ITEM 8.03 POPC ORN $ 2 .0 0

FS

REMARKS

MAKE

MODEL

1.20

1

REFRIGERATED SERVICE COUNTER, LEFT

RANDELL

CUSTOM

CW

HW

DW

IW 1/2"

1.21

1

REFRIGERATED SERVICE COUNTER, RIGHT

RANDELL

CUSTOM

1/2"

1.52B

1

EVAPORATOR COIL

BALLY

CUSTOM

3/8"

+78"

CONDENSATE, EXTEND TO FLOOR SINK

1.62B

1

EVAPORATOR COIL

BALLY

CUSTOM

3/8"

+78"

CONDENSATE, EXTEND TO FLOOR SINK

2.83

1

SOILED DISHTABLE

SELECT STAINLESS

6SD-L-LSL/PR-DM

1/2"

+18"

BTC @ +34", PRE-RINSE SPRAY

3.09

1

GARBAGE DISPOSER, 1 1/2 HP

IN-SINK-ERATOR

SS-150

1/2"

+18"

PIPE THROUGH TO SOLENOID

1/2"

POPC ORN $ 2 .0 0

DOUBLE FULL SIZED CONVECTION OVEN

SOUTHBEND

GS-22SC

3/4"

144

+24"

QUICK DISC.

FOUR BURNER RANGE W/ CABINET BASE

SOUTHBEND

424E

3/4"

134

+24"

QUICK DISC.

4.30

1

GRIDDLE, 48"

STAR

848TS

3/4"

120

+24"

QUICK DISC.

4.34

1

CHAR-BROILER, 24"

STAR

8124RCB

3/4"

80

+24"

QUICK DISC.

8.18

4.36

1

FRYER BATTERY, TWO FRYERS AND FILTER

PITCO

SG18S/18-2UFM

3/4"

140

+24"

QUICK DISC.

3/4"

140

+24"

QUICK DISC.

8.03

7.01

4

HAND SINK

SELECT STAINLESS

SHS-1-ST-SK

1/2"

1/2"

7.04

1

MOP SINK

SELECT STAINLESS

MS-2028-8/8-MF

1/2"

1/2"

7.09

1

3-COMPARTMENT CORNER SINK

SELECT STAINLESS

3BC1824-2D18

1/2"

1/2"

1/2"

1/2"

+18"

POPC ORN $ 2 .0 0

+36"

POPC ORN $ 2 .0 0

7.12

1

WORK TABLE WITH SINK, 72"

SELECT STAINLESS

6SUB-30/B1824

1/2"

1

WAREWASHING MACHINE

HOBART

AM-15T-2

BTC @ +34"

+18"

EXTEND TO FLOOR SINK

1 1/2"

+18"

EXTEND TO FLOOR SINK

1 1/2"

+18"

EXTEND TO FLOOR SINK

+18"

BTC @ +34"

+18"

EXTEND TO FLOOR SINK

+6"

110° INCOMING

+7"

EXTEND TO FLOOR SINK

1/2"

+32"

EXTEND TO MANIFOLD DRAIN TO FLOOR SINK

1 1/2"

+32"

SODA DRAIN, EXTEND TO MANIFOLD TO FLOOR SINK

+6"

ICE BIN, EXTEND TO MANIFOLD TO FLOOR SINK

3/4" 1 1/2"

8.03 POPC ORN $ 2 .0 0

4.34

8

BEER DRAINER

8.18

5

SODA DISPENSER WITH ICE BIN

NIKEC

POLAR BEER BY VENDOR

0510-1012

8.22

5

CARBONATOR

NIKEC

BY VENDOR

8.47

1

ICE BIN, 1300#

FOLLETT

SG-1300-48

8.53

1

ICE CUBER WITH REMOTE COND. UNIT, 1300# ICE CUBER

HOSHIZAKI

KM-1300MWH

1 1/2" FS

+18"

1/2" 1"

1.20 8.03

4.28

REMOTE

HOSHIZAKI

+8"

EXTEND TO FLOOR SINK

+90"

THROUGH FILTER

3/4"

+66"

ICE MAKER DRAIN, EXTEND TO FLOOR SINK

3/8"

+66"

CONDENSATE DRAIN, EXTEND TO FLOOR SINK

1/2"

POPC ORN $ 2 .0 0

4.08

8.03

BTC @ +34"

+18"

1 1/2" 7.37

8.18

+18" 1 1/2"

1/2"

8.22

4.30

MOP FAUCET

FLOOR

2"

8.18

BTC @ +34"

+18"

1 1/2"

8.03

540/786-3663 (VOICE) 540/786-3673 (FAX)

+12"

1

FS

4.36

CONDENSATE, EXTEND TO FLOOR SINK

1

1.21

4.36

GAS CONN. HT. REMARKS

4.28

8.22

GAS SUPPLY FROM BELOW

MBTU

4.08

8.18

FS

PIPE

CONDENSATE, EXTEND TO FLOOR SINK

1 1/2" 8.03

GAS SUPPLY

CONN. HT. REMARKS

RECREATION PARK

7.01

QTY DESCRIPTION

9508 Flint Hill Court Fredericksburg, VA 22407

URC-12F

FS 8.18 8.22 7.12

8.18

FS

8.03

7.12 POPC ORN $ 2 .0 0

8.53

FS

PLUMBING NOTES

FS

8.53 8.47

8.53 POPC ORN $ 2 .0 0

Services shown relate to foodservice equipment requirements only. See architectural and/or engineering drawings for additional plumbing requirements. Plumbing/Mechanical division is responsible for:

7.01 8.03 8.18 8.22 8.18 FS

COLD WATER SUPPLY

• All water, waste, gas, steam and HVAC service to foodservice equipment including piping, fittings, sleeves, stops, valves, traps, cleanouts, insulation and hardware up to and including final connections. • Provision of all exposed piping and fittings in chrome or stainless steel. • Individually valving each supply connection. • Provision of all grease trap and grease recovery units. • Interconnecting ventilators and control panels, detergent systems, waste systems, water treatment and purification systems and warewasher-booster heater (if used).

7.01

1.52

• Installing fire control gas or electric shut-off valve provided with fire suppression system. • Indirect waste lines from walk-in refrigerator/freezer in aluminum, pvc or copper, including 36 watt per lineal foot heat tape and insulation inside freezers. Set lines securely and 3/4” clear of walls. • Provision and installation of water filtration system for kitchen ingredient water. • Providing vacuum breaker (for all disposer systems), kitchen equipment sink faucets,

PLUMBING SYMBOLS UP+ +

STUB-UP FROM FLOOR DISTANCE ABOVE FINISHED FLOOR

DN+

DISTANCE DOWN TO FINISHED FLOOR

BTC

BRANCH TO CONNECTION(S)

CW

COLD WATER

HW

HOT WATER

IW

INDIRECT WASTE

DW

DIRECT WASTE

FD

FLOOR DRAIN

FFD FS OSD

FUNNEL FLOOR DRAIN FLOOR SINK OPEN SITE DRAIN GAS

MBTU

MAIN CONCOURSE CONCESSION STAND FOODSERVICE PLUMBING PLAN

8.22

VISALIA, CA

8.18

1000 BTU/HR

1.62

waste and special fittings, rinse sprays and hoses except as noted. • Provide positive ventilation in all areas. Mechanical division is responsible for the proper operation of all indoor air cooled condensing units. 7.04

REVISION HISTORY 3.09

17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

3.09 2.83

FS 7.09

7.09

7.09

7.09

FS

7.37

7.37

7.09

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

BY

JD

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-1.2

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

KEC TO COORDINATE WALL BACKING FOR HAND SINK WITH GC

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407

POPC ORN $ 2 .0 0

KEC TO COORDINATE WALL BACKING FOR HAND SINK WITH GC

540/786-3663 (VOICE) 540/786-3673 (FAX)

All piping, conduit, BX cable, and similar construction will be either located inside a wall or installed with a minimum 3/4” space from the wall or sealed to the wall.

Finishes in all foodservice areas must be smooth and easily cleanable, durable, impervious to moisture, and light in color with at least 70% reflectivity.

All sink installations will be equipped with hot and cold running water through a mixing valve or combination faucet.

All doors to the outside will be self closing and rodent proof.

Walls to be epoxy painted "greenboard" with full height fiberglass reinforced panels (FRP) or ceramic tile installed behind all sinks and wet areas, or CMU sealed with block filler and epoxy paint.

All painting will be lead-free, non-metallic enamel paint or a high quality varnish. Waste water from all applicable foodservice equipment will be individually plumbed to an open-site drain with a minimum 1” air gap. All sealants must be listed as approved by the National Sanitation Foundation (NSF) under Standard 151. Sealants are to be used only in structurally sound joints and seams.

POPC ORN $ 2 .0 0 POPC ORN $ 2 .0 0

KEC TO COORDINATE OPENINGS IN WALL FOR PASS THROUGH UNITS

All rest room doors will be self closing. All rest rooms will be equipped with mechanical exhaust ventilation sized at a minimum rate of two (2) cubic feet per minute per square foot of floor area and exhausted directly to the outside.

Sealants may be used top fill spaces and openings such as, but not limited to, blind rivet heads and slot and phillips head screws.

All floor mounted equipment will be placed on National Sanitation Foundation (NSF) approved 6” legs, or the equivalent, and properly spaced from adjacent equipment, or walls; or placed on NSF approved casters, or the equivalent; or properly sealed to adjacent surfaces.

Openings around service and utility lines should be closed insofar as practical by: (1) collars or grommets, or (2) flexible form gaskets.

All counter mounted foodservice equipment weighing in excess of 80 pounds will be mounted on NSF approved 4” legs.

Sealants may be used to seal service and utility lines to walls or adjacent pieces of equipment where the spacing is closed to less than 1/8”.

All exposed raw wood will be sealed.

Sealants may not be utilized in food and splash contact surfaces, to fill open spaces or voids which result due to improper design or fabrication. Any opening in excess of 1/8” shall be considered excessive and must be closed using proper field joints.

Wall backing for wall shelves, hand sinks, three compartment sinks and other wall mounted equipment will be required by the general contractor in all foodservice areas. Floor finish to be quarry tile with flush dark color grout, poured composition sanitary flooring or heat-seamed sheet product coved to all walls, corners and equipment bases. Ceiling finishes to be mylar or vinyl faced lay-in tile in white enamel grid. Height above finished floor to be as high as possible in foodservice areas. Conditions shown relate to foodservice equipment as specified. All field conditions must be verified by the fabricator and contractor prior to construction.

All annular openings in construction will be sealed to within 1/32”. All aisles will be a minimum of 36” wide, per National Fire Protection Association Standard 101).

POPC ORN $ 2 .0 0

KEC TO COORDINATE WALL BACKING FOR WALL SHELF AND WORK TABLE WITH SINK

Light levels of shielded light consitent with local codes will be provided at all work surfaces in storage areas, food preparation areas, utensil washing areas, toilet rooms, locker rooms, and in garbage and rubbish storage areas.

RECREATION PARK

POPC ORN $ 2 .0 0

PROVIDE 42" HIGH WALL WITH 36" HIGH GLASS STOREFRONT WHERE HATCHED

The outside storage of refuse will be in rodent-proof containers located on a paved surface with sufficient drainage.

POPC ORN $ 2 .0 0

KEC TO COORDINATE WALL BACKING FOR HAND SINK WITH GC

VISALIA, CA

GENERAL NOTES

POPC ORN $ 2 .0 0

KEC TO COORDINATE OPENINGS IN WALL FOR PASS THROUGH UNITS

MAIN CONCOURSE CONCESSION STAND FOODSERVICE SPECIAL CONDITIONS PLAN

POPC ORN $ 2 .0 0

KEC TO COORDINATE WALL BACKING FOR WALL SHELF

PROVIDE LEVEL FLOOR FOR COOLER ERECTION

KEC TO COORDINATE WALL BACKING FOR WALL SHELF DISHTABLE AND 3 COMP SINK WITH GC

REVISION HISTORY 17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

BY

JD

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-1.3

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

FOODSERVICE EQUIPMENT SCHEDULE

KEC TO COORDINATE BEER LINES TO BAR AND CONCESSION STAND

2.95

2.94

2.95

8.11

2.94

2.94

8.11

ITEM

QTY

DESCRIPTION

REMARKS

MAKE

MODEL

1.51

1

WALK-IN COOLER/FREEZER, LOWER LEVEL

BALLY

CUSTOM

1.53A

1

CONDENSING UNIT, FOOD COOLER

BALLY

CUSTOM

1.53B

1

EVAPORATOR COIL, FOOD COOLER

BALLY

CUSTOM

1.54A

1

CONDENSING UNIT, BEVERAGE COOLER

BALLY

CUSTOM

1.54B

1

EVAPORATOR COIL, BEVERAGE COOLER

BALLY

CUSTOM

1.63A

1

CONDENSING UNIT, FOOD FREEZER, LOWER

BALLY

CUSTOM

1.63B

1

EVAPORATOR COIL, FOOD FREEZER, LOWER

BALLY

CUSTOM

2.40

2

HIGH DENSITY SHELVING SYSTEM, 12'-0" x 4'-0"

ISS

EZ TRACK

2.48

3

SHELVING, 4-TIER, SEALED 21 X 48

ISS

S4546E

2.64

15

DUNNAGE RACK 22 X 36

ISS

DR536Y

2.65

6

DUNNAGE RACK 22 X 48

ISS

DR548Y

2.66

1

DUNNAGE RACK 24 X 60

ISS

DR560Y

2.68

3

SHEET PAN RACK

NEW AGE

1635

2.94

4

KEG RACK, 8 KEGS

POLAR

CUSTOM

2.95

2

KEG RACK, 4 KEGS

POLAR

CUSTOM

8.11

2

BEER SYSTEM POWER PACK

POLAR BEER

405

8.16

2

BAG IN BOX RACK

BY VENDOR

8.17

2

CO2 TANKS

BY VENDOR

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407 540/786-3663 (VOICE) 540/786-3673 (FAX)

2.64

2.64

2.65

2.65

RECREATION PARK

2.65

2.48

INSTALL COOLER/FREEZER WALLS ON INSULATED SLAB. KEC TO COORD. SIZE AND CONFIG. OF INSULATED SLAB WITH G.C.

All sink installations will be equipped with hot and cold running water through a mixing valve or combination faucet. All painting will be lead-free, non-metallic enamel paint or a high quality varnish. Waste water from all applicable foodservice equipment will be individually plumbed to an open-site drain with a minimum 1” air gap. All sealants must be listed as approved by the National Sanitation Foundation (NSF) under Standard 151.

2.65 2.65

2.48

Sealants are to be used only in structurally sound joints and seams. Sealants may be used top fill spaces and openings such as, but not limited to, blind rivet heads and slot and phillips head screws.

1.51

Openings around service and utility lines should be closed insofar as practical by: (1) collars or grommets, or (2) flexible form gaskets. Sealants may be used to seal service and utility lines to walls or adjacent pieces of equipment where the spacing is closed to less than 1/8”.

1.54A

Sealants may not be utilized in food and splash contact surfaces, to fill open spaces or voids which result due to improper design or fabrication. Any opening in excess of 1/8” shall be considered excessive and must be closed using proper field joints.

2.40

2.40

All piping, conduit, BX cable, and similar construction will be either located inside a wall or installed with a minimum 3/4” space from the wall or sealed to the wall. 2.66

All doors to the outside will be self closing and rodent proof.

1.63A

1.53B

1.63B

Light levels of shielded light consitent with local codes will be provided at all work surfaces in storage areas, food preparation areas, utensil washing areas, toilet rooms, locker rooms, and in garbage and rubbish storage areas. 2.68

2.64

2.64

2.64

2.64

2.64

2.64

2.64

2.64

2.68

2.68

All rest room doors will be self closing. All rest rooms will be equipped with mechanical exhaust ventilation sized at a minimum rate of two (2) cubic feet per minute per square foot of floor area and exhausted directly to the outside. All floor mounted equipment will be placed on National Sanitation Foundation (NSF) approved 6” legs, or the equivalent, and properly spaced from adjacent equipment, or walls; or placed on NSF approved casters, or the equivalent; or properly sealed to adjacent surfaces. All counter mounted foodservice equipment weighing in excess of 80 pounds will be mounted on NSF approved 4” legs.

FOODSERVICE EQUIPMENT PLAN

GENERAL NOTES

VISALIA, CA LOWER LEVEL STORAGE AREA

8.16

8.16

KEC TO COORDINATE SODA LINES TO BAR AND CONCESSION STAND

The outside storage of refuse will be in rodent-proof containers located on a paved surface with sufficient drainage.

1.54B

1.53A

8.16

2.48

8.16

8.17

8.17

All exposed raw wood will be sealed. 2.64

2.64

2.64

All annular openings in construction will be sealed to within 1/32”. All aisles will be a minimum of 36” wide, per National Fire Protection Association Standard 101). Finishes in all foodservice areas must be smooth and easily cleanable, durable, impervious to moisture, and light in color with at least 70% reflectivity. Walls to be epoxy painted "greenboard" with full height fiberglass reinforced panels (FRP) or ceramic tile installed behind all sinks and wet areas, or CMU sealed with block filler and epoxy paint. Wall backing for wall shelves, hand sinks, three compartment sinks and other wall mounted equipment will be required by the general contractor in all foodservice areas. Floor finish to be quarry tile with flush dark color grout, poured composition sanitary flooring or heat-seamed sheet product coved to all walls, corners and equipment bases. Ceiling finishes to be mylar or vinyl faced lay-in tile in white enamel grid. Height above finished floor to be as high as possible in foodservice areas.

REVISION HISTORY

Conditions shown relate to foodservice equipment as specified. All field conditions must be verified by the fabricator and contractor prior to construction.

17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2008

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

BY

JD

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-2.0

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407

8.11

8.11

540/786-3663 (VOICE) 540/786-3673 (FAX)

FOODSERVICE ELECTRICAL SCHEDULE ELECTRICAL 1

REMARKS

WALK-IN COOLER/FREEZER, LOWER LEVEL

MAKE

MODEL

BALLY

CUSTOM

1.53A

1

CONDENSING UNIT, FOOD COOLER

BALLY

CUSTOM

1.53B

1

EVAPORATOR COIL, FOOD COOLER

BALLY

CUSTOM

1.54A

1

CONDENSING UNIT, BEVERAGE COOLER

BALLY

CUSTOM

1.54B

1

EVAPORATOR COIL, BEVERAGE COOLER

BALLY

CUSTOM

1.63A

1

CONDENSING UNIT, FOOD FREEZER, LOWER

BALLY

CUSTOM

1.63B

1

EVAPORATOR COIL, FOOD FREEZER, LOWER

BALLY

CUSTOM

8.11

2

BEER SYSTEM POWER PACK

POLAR BEER

405

KW

HP

VOLTS

PHASE

TYPE

NEMA

120

1

J-BOX

DIRECT

DN +102" COOLER LIGHTS

120

1

J-BOX

DIRECT

DN +102" COOLER LIGHTS

120

1

J-BOX

DIRECT

DN +102" FREEZER DOOR HEATER

120

1

J-BOX

DIRECT

DN +102" FREEZER LIGHTS

9.5

208

3

J-BOX

DIRECT

VERIFY

6.8

120

1

J-BOX

DIRECT

DN +102"

2 1/2

11.4

208

3

J-BOX

DIRECT

VERIFY

6.8

120

1

J-BOX

DIRECT

DN +102"

3

14.9

208

3

J-BOX

DIRECT

VERIFY

3.6

208

1

J-BOX

DIRECT

DN +102"

1/4

16.0

120

1

DR

5-15

VERIFY

1 1/2

AMPS

CONN. HT. REMARKS

1.53A

1.54A

ELECTRICAL NOTES

ELECTRICAL SYMBOLS

Services shown relate to foodservice equipment requirements only and show only the point of connection. Convenience receptacles, switches, clock outlets, telephone and computer conduits, HVAC, lighting and

UP+

other power requirements are not included in these drawings. Electrical system is designed for 120/208 3 ph, 4 wire, 60 hz. Electrical division is responsible for:

DN+

DISTANCE DOWN TO FINISHED FLOOR

BTC

BRANCH TO CONNECTION POINT(S)

• All wiring, fittings and labor, up to and including final connections. • Interwiring ventilator, fire protection, waste disposal, remote refrigeration and ice cuber systems. • Provision of all exposed hardware and fixtures to be waterproof and made of chrome or 1.51

1.51 1.63A 1.51

other corrosion resistant material. • Coordination of panelboards with an appropriate diversity factor and 20% spare capacity. • Provision of shunt trip breakers for cooking equipment as required.

+

DISTANCE ABOVE FINISHED FLOOR

V

VOLTS

PH

PHASE

A

AMPS

KW

KILOWATTS

HP

HORSEPOWER EQUIPMENT CONNECTION

• Provision of ground fault protector breakers or outlets as required. • All electrical work within fabricated equipment will be by the supplier, ready for final, single point

DUPLEX RECEPTACLE

connection, unless otherwise noted. • Connection of fire suppression system to microswitch or shunt trip breaker in electrical panel to provide automatic shut-off to cooking equipment, and connection to fire alarm as required.

STUB-UP FROM FLOOR

SINGLE RECEPTACLE JB

JUNCTION BOX ( CEILING MOUNTED LIGHT

SW

SWITCH

1.53B

1.63B

SPECIAL CONNECTION AS NOTED

FOODSERVICE ELECTRICAL PLAN

1.51

DESCRIPTION

VISALIA, CA LOWER LEVEL STORAGE AREA

1.51

QTY

RECREATION PARK

1.54B

ITEM

REVISION HISTORY 17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2008

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

BY

JD

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-2.1

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407

FOODSERVICE PLUMBING SCHEDULE PLUMBING 1

1.54B

1

1.63B

1

REMARKS

MAKE

MODEL

EVAPORATOR COIL, FOOD COOLER

BALLY

CUSTOM

3/8"

+78"

EXTEND TO FLOOR SINK

EVAPORATOR COIL, BEVERAGE COOLER

BALLY

CUSTOM

3/8"

+78"

EXTEND TO FLOOR SINK

EVAPORATOR COIL, FOOD FREEZER, LOWER

BALLY

CUSTOM

3/8"

+78"

EXTEND TO FLOOR SINK

PLUMBING NOTES

HW

DW

IW

CONN. HT. REMARKS

UP+

Plumbing/Mechanical division is responsible for:

DN+

• All water, waste, gas, steam and HVAC service to foodservice equipment including piping, fittings, sleeves, stops, valves, traps, cleanouts, insulation and hardware up to

DISTANCE DOWN TO FINISHED FLOOR

BTC

BRANCH TO CONNECTION(S)

• Provision of all exposed piping and fittings in chrome or stainless steel. • Individually valving each supply connection. • Provision of all grease trap and grease recovery units. • Interconnecting ventilators and control panels, detergent systems, waste systems, water treatment and purification systems and warewasher-booster heater (if used). • Installing fire control gas or electric shut-off valve provided with fire suppression system. • Indirect waste lines from walk-in refrigerator/freezer in aluminum, pvc or copper, including 36 watt per lineal foot heat tape and insulation inside freezers. Set lines securely and 3/4” clear of walls. • Provision and installation of water filtration system for kitchen ingredient water. • Providing vacuum breaker (for all disposer systems), kitchen equipment sink faucets, waste and special fittings, rinse sprays and hoses except as noted.

PIPE

MBTU

GAS CONN. HT. REMARKS

540/786-3663 (VOICE) 540/786-3673 (FAX)

PLUMBING SYMBOLS

Services shown relate to foodservice equipment requirements only. See architectural and/or engineering drawings for additional plumbing requirements.

and including final connections.

1.54B

CW

+

STUB-UP FROM FLOOR DISTANCE ABOVE FINISHED FLOOR

CW

COLD WATER

HW

HOT WATER

IW

INDIRECT WASTE

DW

DIRECT WASTE

FD

FLOOR DRAIN

FFD FS OSD

FUNNEL FLOOR DRAIN FLOOR SINK OPEN SITE DRAIN GAS

MBTU

1000 BTU/HR

• Provide positive ventilation in all areas. Mechanical division is responsible for the proper operation of all indoor air cooled condensing units.

1.53B

1.63B

FS

FS

FOODSERVICE PLUMBING PLAN

1.53B

DESCRIPTION

VISALIA, CA LOWER LEVEL STORAGE AREA

QTY

RECREATION PARK

ITEM

REVISION HISTORY 17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2008

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

BY

JD

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-2.2

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

8.22

8.40

FOODSERVICE EQUIPMENT SCHEDULE ITEM

QTY

1.37

2

1.38

2

1.39

DESCRIPTION

REMARKS

MAKE

MODEL

BACK BAR REFRIGERATOR, 60"

GLASTENDER

BB60-R6-SNHLR

BACK BAR LIQUOR STEP

GLASTENDER

LLD-42

2

ICED BOTTLE DISPLAY

GLASTENDER

GDU-12X42

7.31

1

UNDERBAR HAND SINK WITH SOAP AND TOWEL

GLASTENDER

DHSB-18

7.33

1

UNDERBAR FOUR COMPARTMENT SINK

GLASTENDER

FSB-72

7.34

1

UNDERBAR DUMP SINK, 12"

GLASTENDER

SWB-12-C

8.08

1

BEER DRAINER, SIX HEAD

POLAR BEER

0510-2224

8.09

1

SIX HEAD BEER DISPENSER

POLAR BEER

2600

8.21

3

SODA GUN WITH HOSE

8.22

3

CARBONATOR

8.40

3

UNDERBAR COCKTAIL STATION, 36"

9.01

3

P.O.S. MACHINE

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407 540/786-3663 (VOICE) 540/786-3673 (FAX)

BY VENDOR NIKEC

BY VENDOR GLASTENDER

NIKEC

IBB-36

QUEST

GENERAL NOTES

7.34

9.01 8.21

8.40

1.37 1.38 1.39

8.21

All sealants must be listed as approved by the National Sanitation Foundation (NSF) under Standard 151.

Sealants may be used top fill spaces and openings such as, but not limited to, blind rivet heads and slot and phillips head screws.

7.31

Openings around service and utility lines should be closed insofar as practical by: (1) collars or grommets, or (2) flexible form gaskets. Sealants may be used to seal service and utility lines to walls or adjacent pieces of equipment where the spacing is closed to less than 1/8”.

8.08

9.01 8.22

1.37 1.38

Waste water from all applicable foodservice equipment will be individually plumbed to an open-site drain with a minimum 1” air gap.

Sealants are to be used only in structurally sound joints and seams.

8.22

8.09

RECREATION PARK

All painting will be lead-free, non-metallic enamel paint or a high quality varnish.

Sealants may not be utilized in food and splash contact surfaces, to fill open spaces or voids which result due to improper design or fabrication. Any opening in excess of 1/8” shall be considered excessive and must be closed using proper field joints. All piping, conduit, BX cable, and similar construction will be either located inside a wall or installed with a minimum 3/4” space from the wall or sealed to the wall.

8.21

1.39

7.33

8.40

All doors to the outside will be self closing and rodent proof. Light levels of shielded light consitent with local codes will be provided at all work surfaces in storage areas, food preparation areas, utensil washing areas, toilet rooms, locker rooms, and in garbage and rubbish storage areas. All rest room doors will be self closing.

9.01

All rest rooms will be equipped with mechanical exhaust ventilation sized at a minimum rate of two (2) cubic feet per minute per square foot of floor area and exhausted directly to the outside. All floor mounted equipment will be placed on National Sanitation Foundation (NSF) approved 6” legs, or the equivalent, and properly spaced from adjacent equipment, or walls; or placed on NSF approved casters, or the equivalent; or properly sealed to adjacent surfaces. All counter mounted foodservice equipment weighing in excess of 80 pounds will be mounted on NSF approved 4” legs. All exposed raw wood will be sealed.

VISALIA, CA

All sink installations will be equipped with hot and cold running water through a mixing valve or combination faucet.

CLUB BAR FOODSERVICE EQUIPMENT PLAN

The outside storage of refuse will be in rodent-proof containers located on a paved surface with sufficient drainage.

All annular openings in construction will be sealed to within 1/32”. All aisles will be a minimum of 36” wide, per National Fire Protection Association Standard 101). Finishes in all foodservice areas must be smooth and easily cleanable, durable, impervious to moisture, and light in color with at least 70% reflectivity. Walls to be epoxy painted "greenboard" with full height fiberglass reinforced panels (FRP) or ceramic tile installed behind all sinks and wet areas, or CMU sealed with block filler and epoxy paint. Wall backing for wall shelves, hand sinks, three compartment sinks and other wall mounted equipment will be required by the general contractor in all foodservice areas. Floor finish to be quarry tile with flush dark color grout, poured composition sanitary flooring or heat-seamed sheet product coved to all walls, corners and equipment bases. Ceiling finishes to be mylar or vinyl faced lay-in tile in white enamel grid. Height above finished floor to be as high as possible in foodservice areas. Conditions shown relate to foodservice equipment as specified. All field conditions must be verified by the fabricator and contractor prior to construction.

REVISION HISTORY 17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

ISSUED

5 SEPTEMBER 2007

REVISED SCALE

1/4" = 1'-0"

BY

JD

CHECKED

TLB

SHEET

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-3.0

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407 540/786-3663 (VOICE) 540/786-3673 (FAX)

FOODSERVICE ELECTRICAL SCHEDULE ELECTRICAL REMARKS

MAKE

MODEL

1.37

2

1.38

2

BACK BAR REFRIGERATOR, 60"

GLASTENDER

BB60-R6-SNHLR

BACK BAR LIQUOR STEP

GLASTENDER

LLD-42

8.22

3

CARBONATOR

NIKEC

BY VENDOR

9.01

3

P.O.S. MACHINE

NIKEC

QUEST

KW

HP

AMPS

VOLTS

PHASE

TYPE

NEMA

1/3

7.2

120

1

DR

5-15

+18"

2.5

120

1

DR

5-15

+48"

7.2

120

1

DR

5-15

+12"

5.0

120

1

DR

5-15

+48"

1/3

CONN. HT. REMARKS

9.01 1.37 1.38

8.22

9.01 1.37 1.38

8.22

ELECTRICAL NOTES

ELECTRICAL SYMBOLS

Services shown relate to foodservice equipment requirements only and show only the point of connection.

UP+

Convenience receptacles, switches, clock outlets, telephone and computer conduits, HVAC, lighting and other power requirements are not included in these drawings. Electrical system is designed for 120/208 3 ph, 4 wire, 60 hz. Electrical division is responsible for: • All wiring, fittings and labor, up to and including final connections. • Interwiring ventilator, fire protection, waste disposal, remote refrigeration and ice cuber systems. • Provision of all exposed hardware and fixtures to be waterproof and made of chrome or other corrosion resistant material. • Coordination of panelboards with an appropriate diversity factor and 20% spare capacity. • Provision of shunt trip breakers for cooking equipment as required. • Provision of ground fault protector breakers or outlets as required.

9.01

+

DISTANCE ABOVE FINISHED FLOOR

DN+

DISTANCE DOWN TO FINISHED FLOOR

BTC

BRANCH TO CONNECTION POINT(S)

V

VOLTS

PH

PHASE

A

AMPS

KW

KILOWATTS

HP

HORSEPOWER EQUIPMENT CONNECTION

• All electrical work within fabricated equipment will be by the supplier, ready for final, single point connection, unless otherwise noted. • Connection of fire suppression system to microswitch or shunt trip breaker in electrical panel to provide automatic shut-off to cooking equipment, and connection to fire alarm as required.

STUB-UP FROM FLOOR

DUPLEX RECEPTACLE SINGLE RECEPTACLE JB

JUNCTION BOX ( CEILING MOUNTED LIGHT

SW

SWITCH SPECIAL CONNECTION AS NOTED

CLUB BAR FOODSERVICE ELECTRICAL PLAN

DESCRIPTION

VISALIA, CA

QTY

RECREATION PARK

8.22

ITEM

REVISION HISTORY 17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-3.1

201 East Broad Street Spartanburg, SC 29306 9508 Flint Hill Court Fredericksburg, VA 22407 864/598-8670 (VOICE) 864/598-8697 (FAX)

FOOD SERVICE

Resources

Creative Foodservice Design and Operations Expertise

P.O. Box 41099 Fredericksburg, VA 22404 9508 Flint Hill Court Fredericksburg, VA 22407

FS

8.22

8.40

540/786-3663 (VOICE) 540/786-3673 (FAX)

FOODSERVICE PLUMBING SCHEDULE PLUMBING 2

7.31

1

7.33

1

REMARKS

MAKE

MODEL

CW

HW

ICED BOTTLE DISPLAY

GLASTENDER

GDU-12X42

UNDERBAR HAND SINK WITH SOAP AND TOWEL

GLASTENDER

DHSB-18

1/2"

1/2"

UNDERBAR FOUR COMPARTMENT SINK

GLASTENDER

FSB-72

1/2"

1/2"

DW

IW

CONN. HT. REMARKS

1/2"

7.34 8.40

FS

1

UNDERBAR DUMP SINK, 12"

GLASTENDER

SWB-12-C

8.08

1

BEER DRAINER, SIX HEAD

POLAR BEER

0510-2224

8.22

3

CARBONATOR

8.40

3

UNDERBAR COCKTAIL STATION, 36"

1/2"

+12"

7.31

NIKEC

1"

+12"

EXTEND TO FLOOR SINK

1"

+12"

EXTEND TO FLOOR SINK

1"

+12"

EXTEND TO FLOOR SINK

1"

+12"

EXTEND TO FLOOR SINK

+12"

1/2" 1/2"

BY VENDOR GLASTENDER

EXTEND TO FLOOR SINK +32"

EXTEND TO FLOOR SINK

+12"

1/2" IBB-36

EXTEND TO FLOOR SINK

+12"

1" 7.31

1.39

7.34

EXTEND TO FLOOR SINK

+12" 1"

7.34

+40"

1"

+12"

EXTEND TO FLOOR SINK

8.22

FS 8.08

8.22

1.39

8.40

7.33 7.33

FS

7.33 7.33 7.33

PLUMBING NOTES

PLUMBING SYMBOLS

Services shown relate to foodservice equipment requirements only. See architectural and/or engineering drawings for additional plumbing requirements.

UP+

Plumbing/Mechanical division is responsible for: • All water, waste, gas, steam and HVAC service to foodservice equipment including piping, fittings, sleeves, stops, valves, traps, cleanouts, insulation and hardware up to

DN+

DISTANCE DOWN TO FINISHED FLOOR

BTC

BRANCH TO CONNECTION(S)

and including final connections. • Provision of all exposed piping and fittings in chrome or stainless steel. • Individually valving each supply connection. • Provision of all grease trap and grease recovery units. • Interconnecting ventilators and control panels, detergent systems, waste systems, water treatment and purification systems and warewasher-booster heater (if used). • Installing fire control gas or electric shut-off valve provided with fire suppression system. • Indirect waste lines from walk-in refrigerator/freezer in aluminum, pvc or copper, including 36 watt per lineal foot heat tape and insulation inside freezers. Set lines securely and 3/4” clear of walls. • Provision and installation of water filtration system for kitchen ingredient water. • Providing vacuum breaker (for all disposer systems), kitchen equipment sink faucets, waste and special fittings, rinse sprays and hoses except as noted. • Provide positive ventilation in all areas. Mechanical division is responsible for the proper operation

+

STUB-UP FROM FLOOR DISTANCE ABOVE FINISHED FLOOR

CW

COLD WATER

HW

HOT WATER

IW

INDIRECT WASTE

DW

DIRECT WASTE

FD

FLOOR DRAIN

FFD FS OSD

FUNNEL FLOOR DRAIN FLOOR SINK OPEN SITE DRAIN GAS

MBTU

1000 BTU/HR

CLUB BAR FOODSERVICE PLUMBING PLAN

1.39

DESCRIPTION

VISALIA, CA

QTY

RECREATION PARK

ITEM

of all indoor air cooled condensing units.

REVISION HISTORY 17 JULY 2007 18 JULY 2007 24 JULY 2007 5 SEPTEMBER 2007 19 SEPTEMBER 2007 28 SEPTEMBER 2007

THIS DRAWING IS PREPARED TO SHOW ONLY LOCATION AND ARRANGEMENT OF FIXTURES, EQUIPMENT, AND RELATED UTILITY CONNECTION REQUIREMENTS. NO ARCHITECTURAL OR ENGINEERING SERVICE IS INTENDED OR ASSUMED.

FS-3.2