Air sampling
Consumables solutions dust
heat
noise
gas
vibration
light
www.casellameasurement.com
Think Environment Think Casella
Air sampling
Consumables solutions With over 200 years of history, Casella Measurement is today a reputable leader in the development, manufacture and supply of industrial hygiene, occupational health and environmental monitoring instrumentation. As a global company with offices and distributors worldwide, Casella CEL ensure quality service worldwide. The range of air sampling consumables within this catalogue compliment the market leading air sampling pumps that Casella CEL is renowned for - For all your air sampling needs, think Casella CEL.
How To Guide
3
Air Sampling Pumps
6
Personal Air Sampling Pumps (TUFF)
6
Air Sampling Kits
7
Air Sampling Accessories
8
Sampling Heads
8
Asbestos Sampling Media
9
Gas & Vapour Sampling
9
Blank Sampling Cassette Housings
10
Pre-Loaded Cassette Housings
10
Pre-Weighed Filter Cassettes
11
Match Weighed Cassettes
11
Cassette Accessories
11
Impingers and Bubblers
12
Tedlar and Teflon bags
12
Calibration Devices and Adaptors
13
Filters 14
3˚80db16˚
db16˚2.5m/s 2.5m/s130db5.0m/s13˚80db16˚ 3
3
0db16˚4mg/m 0db5.0m/s13˚80db16˚
˚80db16˚ 30db5.0m/s13˚80db16˚
m/s130db5.0m/s13˚80db16˚
GFA
14
MCE
14
PVC
15
PTFE
15
16
Polycarbonate
Quartz
16
Silver
17
17
Support Pads
Sorbent Tubes
18
19
Charcoal
Silica
19
Chromosorb
19
Porapak
20
Tenax
20
XAD
20
Colorimetric Tubes
21
22
Sampling Pumps for Tubes
Notes
2
23
Sampling for particulates, dusts and fumes
Sampling Heads and Cassettes
A complete range of sampling media is available. These filters are used in conjunction with sampling heads or as integral sampling cassettes.
A variety of sampling heads and cassettes are available for asbestos, total inhalable, respirable and other dust fractions. Please refer to the relevant section of the catalogue for further details.
Always refer to the relevant sampling guidance and methodologies (eg. MDHS, OSHA or NIOSH) to ensure selection of the correct sampling media for the analyte to be sampled.
Sampling Train A typical sampling train includes a sampling head (or cassette) complete with filter inserted, connected via a length of tubing to the air sampling pump. Each sampling head requires a specific flow rate and this is set via a calibrator prior to and after sampling. These may be via a simple rotameter or digital flowmeter:
Example of an inhalable head with rotameter
37mm Cassette w/ MCE Filters
25mm Asbestos PCM Cassette
Inhalable Dust Sampler
Cassette with transport clip for Inhalable Dust Sampler
Sampling Filter Media PTFE Filter Membrane • Used for post sampling chemical analysis
Air Sampling Pumps
The volume of air is measured and calculated as a concentration expressed as mg/m3 or parts per million (ppm).
Air Sampling Accessories
The basis for air sampling is to sample a volume of air through a suitable sampling medium, usually paper or solid filter media for particulates and fumes and through sorbent materials for gases and vapours. Another is via impingers and bubblers or a grab sample taken into a gas sampling bag.
How to guide
Introduction to Air Sampling
Filters
• Strong, chemically resistant membranes for air monitoring and sampling in aggressive environments
PVC Membrane Filter • For sampling airborne metals, silica, and dust
• Assures gravimetric stability. Low moisture pick-up and low tare weight • Low ash. Provides interference-free silica determinations
Example of a respirable head with digital flow meter
Glass Microfibre Filter (GFA)
Sorbent Tubes
• Post sampling chemical analysis
• Fastest flow rate and high load capacity • Retention of particles to sub-micron size
Dry Cal
• Most commonly used media for gravimetric dust samples
®
• Inert fibre composition
Primary Flow Meter
• Free of binders or additives
The sampling head should then be mounted on the individual to be sampled, within 30 cms of the breathing zone.
To order call: +44 (0)1234 844 100 or visit www.casellameasurement.com/consumables
Colourmetric Tubes
• Temperature range up to 500°C
3
How to guide
Suitable for a broad range of air monitoring applications
• Smooth glass-like surface with cylindrical pores for maximum particulate capture
• Heat treated for reduction of trace organics and superior chemical purity
• Precise pore sizes and pore distribution for absolute filtration and separation
• High temperature use for analysis of acidic gases and stack sampling aerosols
• Very low extractables
• High flow rate and filtration efficiency
• E xcellent chemical resistance and thermal stability
MCE filter
Air Sampling Accessories
Polycarbonate Membrane Filter
Air Sampling Pumps
Quartz filter
• Suitable for air monitoring applications
• Superior strength
Developed from a mixture of cellulose acetate and cellulose nitrate, MCE membrane filters are one of the most widely used filters in both air monitoring and analytical applications. Not subject to moisture issues and an economical membrane for air monitoring applications
Silver Membrane Filters • 9 9.97% pure silver • High temperature resistance • High chemical resistance • Economical – can be cleaned & reused • Smooth surface for particle capture and easy observation
• Dissolves completely using standard digestion procedures
Material MCE
Filters
PVC
PTFE
Sorbent Tubes
Polycarbonate
Silver
Colourmetric Tubes 4
• Biologically inert
Glass Fibre
Quartz
Main Properties •R eadily soluble for atomic absorption analysis •R eadily rendered transparent for transmitted light microscopy •D issolve and clear easily • L ow moisture pick up. •N on-oxidizing surface •S ilica-free • L ow ash membrane • L ow tare weight for gravimetric analysis • Hydrophobic • Inert to solvents, acids & bases •A ggressive environments
• Hydrophobic •M icroscopically smooth surface •P recise pore sizes • Inert •S trong •W ide solvent compatibility •H igher temperature tolerance • Autoclavable •U niform porosity and thickness •U p to C500 degree range • Inert composition •H igh particulate retention •H eat treated • L ow level metals content •H igh temperature 300°C • Autoclavable •H igh filtration efficiency
Air Sampling Applications • Metal dust analysis • Asbestos & man-made fibers • Air Quality
Sampling for solvents and vapours
• Gravimetric analysis • Hexavalent chromium • Silica
Sampling Train
• Alkaline dusts • PAH’s • Pesticides • Isocyanates • Ambient Air quality • Scanning electron microscopy • Asbestos fibers
Solvents, gases and vapours are sampled actively using air sampling pumps and sorbent tubes, into bubblers, gas bags, direct reading tubes or passively using diffusive sampling badges.
Typical sampling train for gas and vapour adsorbent tube sampling requires a tube with ends broken off inserted into a tube holder and connected to a pump. The pump may be a specific low flow pump or a medium flow pump (Tuff or Apex) with a Constant Pressure Controller (CPC) and low flow adaptor assembly connected. (as shown below). Flow rate (typically 10-120ml/min) needs to be set prior to and post sampling. Constant Pressure Controller
Flow
Low Flow Adaptor
Flow
• Bromine • Asbestos by TEM • Silica by x-ray diffraction
Sorbent Tube in Tube Holder
Apex Pump
• General gravimetric • Isocyanates • Ethylene glycol • Air Quality Fractions • General air sampling • High temperature applications • Stack sampling • Diesel particulates • Acidic gases
Constant Pressure Controller Dry Cal Flowmeter
Flow
Low Flow Adaptor
TEMP19.48
Dry Cal
®
Sorbent Tube in Tube Holder
2.5
Primary Flow Meter
Outlet
Flow
Apex Pump
Bubblers and Impingers
Sorbent materials are used which adsorb the vapour or gas onto
These are used for adsorption of particles acids,
their surface during sampling and this is then desorbed from the
alkalis, vapours and gases via a liquid sorbent. The
material (via other chemicals or thermally) and subjected to further
detection is by dissolution or by chemical reaction.
chemical analysis typically via a gas chromatograph.
Impingers have a tapered outlet which allows
Organic vapors and gases can be collected using several different
particulate matter to exit at high velocity, hit the flask
sampling media including charcoal sampling tubes in conjunction
bottom and be captured into the solution, whilst
with Casella CEL low-flow sampling pumps. For each analyte,
bubblers are open or fritted to increase surface area
a suitable reference work or methodology is consulted. You can
so the gases can be absorbed into solution, these are
refer to Casella Air Sampling Solutions (www.airsamplingsolutions.
generally the preferred solution for gas and vapour
com) or the relevant MDHS, NIOSH or other in territory sampling
sampling.
methodologies for specific details on required sampling media,
Impingers and bubblers can be positioned in an area,
sampling rates, and sampling times for specific chemicals.
held or worn in a holster.
Flow rates vary but generally have to be slow enough for the vapours to be absorbed and are in the range 20–100ml/min. There are generally two sizes of tubes, small and large. For most
Typical sampling train for bubblers:
routine sampling the small size will suffice but in suspected high
Optional items for use ONLY in low flow applications
concentration areas the larger size may be more appropriate to avoid saturation of the tubes. Always refer to the sampling
Constant Pressure Controller P109027
methodologies for the media and the required sample volume and
Low Flow Adaptor P109026
flow rate.
Typical sorbent sampling tube.
Flow
Flow
Carbon Trap P109018
TEMP 19.48
2.5
Air Sampling Accessories
Air Sampling Pumps
How to guide
Solid Sorbent Sampling Tubes
Impinger / Bubbler
Diffusive (Passive) Sampling Diffusive or passive samplers are also used for
Filters
Sampling Pump
background sampling. Badges are opened for sampling, worn on the person, sealed and sent off for analysis where the substances are desorbed via another solvent and subjected to gas chromatography.
Chromopak, Tenax and others. Silica gel is also used as the adsorbent material for polar hydrocarbons, low molecular weight mercaptans, methanol, amines and inorganic acids. Some specially reagent treated tubes are also used eg 2,4-dinitrophenylhydrazine for aldehyde sampling, sulphuric acid treated for ammonia.
Gas Sampling Bags These are constructed from a range of materials. The bags are used with a sampling pump and can be used for grab
Sorbent Tubes
Various adsorbent materials are used including Charcoal,
sampling or for longer term sampling at lower
Most tubes have several layers of material, where the smaller layer
flow rates. A range of capacities is available.
is the back up layer and should be closest to the sampling pump inlet (If printed arrows are present, point arrow towards pump). tube in an approximately vertical position on the body and the tube sealed with the cap ends and sealing tape and sent off for analysis.
Direct Reading Colour Detection Tubes These are glass vials, filled with chemical reagents that react to a specific chemical or family of chemicals. A known volume sample is drawn through the tube via a hand
The two layers will be analysed separately, and if the back up layer is more that 10% of the main layer the tube is deemed as saturated, and the sample will be discarded.
syringe for a set number of pulls (indicated on the tube). If the targeted chemical is present, the reagent in the tube changes colour, with the length of the colour read against
Charcoal tubes are the most common type of tube for organic
a concentration scale on the tube. Select the appropriate
vapour sampling, but are not always suitable.
tube for the required hazard.
To order call: +44 (0)1234 844 100 or visit www.casellameasurement.com/consumables
Colourmetric Tubes
Both ends of the tube are broken off, the sample taken with the
5
Personal Sampling Pumps How to guide
TUFF™ Air Sampling Pump
Air Sampling Pumps
The TUFF range of personal air sampling pumps offer the user an extremely robust, rubber overmoulded unit designed specifically for use in harsh monitoring environments. With the range offering a wide flow rate from 5 ml/ min* to 4.5 l/min. TUFF pumps are ideally suited to a wide range of occupational health sampling applications from simple abatement sampling of lead and asbestos, to more specialised industrial hygiene monitoring of dusts, fumes and vapours. The units offer excellent functionality at a competitive price.
Air Sampling Accessories
TUFF has been ergonomically designed for user comfort with easy to read display and high intensity alarm LED’s for fault indication. The TUFF range meet EN1232 and NIOSH 0600 requirements for personalised sampling pumps in workplace environments.
TUFF pumps are available with either 3 or 4.5 l/ min maximum flow rate capability. Standard, Plus and Pro models then provide different levels of functionality and programmability: TUFF Standard Models: Entry level pumps for abatement and general sampling applications. With simple single point flow setting, elapsed run time counter and run mode only. Simple battery life indication. Drop in fast charger. TUFF Plus Models:
Key Features
Offer additional functionality including: Display of flow set point, real time flow rate, accumulated sample time and volume. Programmable Run Duration mode. Upgradeable to Pro.
• Robust and reliable design for harsh environments (IP54)
Intrinsically Safe (I.S.) Models:
• Rubber over-moulded sealed case • Outstanding operational duration
Filters
• Exceptional flow control • Convenient drop in charging/storage system • Intelligent battery management – Fast battery charge 20hrs 1.7Ah
*with low flow adaptor
Ordering Information: Pumps are configured when ordered via a selection matrix. All part numbers start with the letter ‘P’, then select if intrinsic safety is required, then select the pump variant you require – either 3 or 4.5 l/min flow range, standard, Plus or Pro variant and select the appropriate prefix. Then select the battery you require standard (1.7Ah) or high capacity (2.7Ah). Finally select if charger is required. The corresponding ‘P’ number is the part number used for ordering.
Product: 30 Non-I.S. 31 I.S. 32 M1 Certified I.S. for Mining
Pump Variants: Tuff 3 31 Tuff 3 + 32 Tuff 3 Pro 33 Tuff 4 41 Tuff 4 + 42 Tuff 4 Pro 43
Charger: None 0 1way 1
Battery: No Battery 0 Standard 1 High Capacity 2
Pumps can be configured to application by completing the matrix: P
Product
Variant
3
x
x
x
Battery
Charger
x
x
Air Sampling Accessories