PRODUCT DATA SHEET PDS B72_E

PRODUCT DATA SHEET PDS B72_E TERMO-ROLL H2 Heat-shrinkable tubing on reel for Rolly2000 thermal transfer printers with appropriate ribbon Materi...
Author: Winfred Smith
1 downloads 0 Views 348KB Size


PRODUCT DATA SHEET

PDS B72_E

TERMO-ROLL H2 Heat-shrinkable tubing on reel for Rolly2000 thermal transfer printers with appropriate ribbon

Material:

Description:

H2 type heat-shrinkable tubing is used to provide highly legible and resistant • Extruded, cross-linked polyolefin identification of cables, pipes, conduits, etc within a minimum space. • 2:1 shrinkage ratio Halogen free composition provides flame retardancy and low smoke • Flame retardant emission characteristics suitable for safety critical applications including closed environments such as tunnels and subways, rail installations, marine • Halogen free and industrial applications. • Low Smoke Emission • Good resistance to fluids & solvents

Technical:

Minimum shrinkage temperature:

Property

Test method

Typical value

Tensile strength Elongation at break Longitudinal change Water absorption Specific gravity

ASTM D 638 ASTM D 638 ASTM D 2671 ASTM D 570 ASTM D 792

13 N/mm2 200% ≤ +5% ≤ -10% ≤ 0.15%

1.4 g/cm

3

• 90°C Operating temperature range: • -30°C to +105°C Standard colours: • White and yellow Storage:

Electrical:

• Store in original packaging Property

Test Method

Typical value

Dielectric strength Volume resistivity

ASTM D 2671 ASTM D 257

20 kV/mm 1014 ΩΩ cm

• Use within 3 years of the date of manufacture printed on the reel Temperature range: • 10°C÷25°C

Chemical : Property

Test Method

Typical value

Fungal resistance Chemical resistance Copper corrosion Oxygen index

AMS-DTL-7444 AMS-DTL-23053/5 ASTM D 2671B ASTM D 2863

Inert, no growth Good No corrosion 36%

Thermal : Property

Test Method

Typical value

No dripping, cracking or flowing Heat ageing 168 hours at 150°C ASTM D 638 Elongation 100% Low temperature flex. -30°C ASTM D 2671C No cracking Flammability ASTM D 635 Pass » flame retardant Heat shock 4 hours at 175°C

ASTM D 2671

·1/5·

Relative humidity range: • 45÷55%



PRODUCT DATA SHEET

PDS B72_E

Smoke density: Specification

Flame propagation

BS ISO 4589-2 Annex A France (NF16-101) NF T 51-071 & NF C 20-455 America (NFPA130) ASTM 162 Germany (DIN 5510-2) DIN 54837 UK (BS 6853)

Toxicity

Smoke generation

BS 6853 Ap. B1 BS 6853 D8.3 or NF X-70-100 NF X 70-100 NF X 10-702 BSS 7239 DIN ISO 5659

ASTM 662 DIN ISO 5659

Fire performance requirements for use on railway vehicles as per CEN/TS 45545-2:2013 Requirement Test methods

R23 EN ISO 4589-2

LOI(%) Typical value

Acceptance limits

EN ISO 5659-2 (25kW/m2-Flaming)

33.5

Ds max 49.5 (Flaming)

for HL1: ≥ 28% HL2: ≥ 28% HL3: ≥ 32%

for HL1: ≤ 600 HL2: ≤ 300 HL3: ≤ 150

NF X 70-100-1/-2

CITNLP 0.10 for HL1: ≤ 1.2 HL2: ≤ 0.9 HL3: ≤ 0.75

Indelibility of printed marking: • MIL-STD-202G test method 215 2002 Resistance to solvents (MIL81531/SAE-AS81531-1998 clause 3.4.3.) Passed with following black ribbons: TRR-055 843121,TRR-055 842121 • EN 50343:2003 Railway applications. Rolling stock. Rules for installation of cabling

Cembre SpA Via Serenissima, 9 - 25135 Brescia (Italy) Tel.: +39 030 36921 - Fax: +39 030 3365766 Web: www.cembre.com - Email: [email protected]

Prepared by Marketing dept. Date: 14/10/2015

· 2 / 5·



PRODUCT DATA SHEET

PDS B72_E

H2

HEAT-SHRINKABLE TUBING ladder-printable on one side only

LADDER

with ROLLY2000TR1 990980 printer and black ribbon TRR-055 842121.

H2-24 Colour white

H2-32 white

yellow

non-printable side, protected by transparent adhesive film

H2-48 white

yellow

H2-64 white

printable side

yellow

H2-95 white

yellow

H2-127 white yellow

4 2 1

TUBES PER STEP 12,5 mm

12,5 mm

12,5 mm

12,5 mm

H2-190 white yellow

25 mm

25 mm

H2-254 white yellow

50 mm

H2-381 white yellow

H2-508 white

Cable ext. Ø range 1,6 ÷ 2 mm (0.06” - 0.08” in.) Cable c.s.a range 0,25 ÷ 0,5 mm2 (26 - 20 AWG) Internal Ø before shrinking mm

Pre-cut length mm

Code

Tubes per step

Quantity

SW Code

12,5 25 50

H2-24-12.5-WH1 H2-24-25-WH1 H2-24-50-WH1

4 2 1

4.000 2.000 1.000

4800 4802 4804

12,5 25 50 12,5 25 50

H2-32-12.5-WH1 H2-32-25-WH1 H2-32-50-WH1 H2-32-12.5-YE1 H2-32-25-YE1 H2-32-50-YE1

4 2 1 4 2 1

4.000 2.000 1.000 4.000 2.000 1.000

4810 4812 4814 4810 4812 4814

12,5 25 50 12,5 25 50

H2-48-12.5-WH1 H2-48-25-WH1 H2-48-50-WH1 H2-48-12.5-YE1 H2-48-25-YE1 H2-48-50-YE1

4 2 1 4 2 1

4.000 2.000 1.000 4.000 2.000 1.000

4820 4822 4824 4820 4822 4824

12,5 25 50 12,5 25 50

H2-64-12.5-WH1 H2-64-25-WH1 H2-64-50-WH1 H2-64-12.5-YE1 H2-64-25-YE1 H2-64-50-YE1

4 2 1 4 2 1

4.000 2.000 1.000 4.000 2.000 1.000

4830 4832 4834 4830 4832 4834

12,5 25 50 12,5 25 50

H2-95-12.5-WH1 H2-95-25-WH1 H2-95-50-WH1 H2-95-12.5-YE1 H2-95-25-YE1 H2-95-50-YE1

4 2 1 4 2 1

2.000 1.000 500 2.000 1.000 500

4840 4842 4844 4840 4842 4844

12,7 12,7

50 50

H2-127-50-WH1 H2-127-50-YE1

1 1

500 500

4854 4854

19,1 19,1

50 50

H2-190-50-WH1 H2-190-50-YE1

1 1

500 500

4864 4864

25,4 25,4

50 50

H2-254-50-WH1 H2-254-50-YE1

1 1

300 300

4874 4874

38,1 38,1

50 50

H2-381-50-WH1 H2-381-50-YE1

1 1

300 300

4884 4884

50,8

50

H2-508-50-WH1

1

100

4894

2,4

Cable ext. Ø range 1,8 ÷ 2,8 mm (0.07” - 0.11” in.) Cable c.s.a range 0,5 ÷ 1 mm2 (24 - 18 AWG) 3,2 3,2

Cable ext. Ø range 2,8 ÷ 4,2 mm (0.11” - 0.16” in.) Cable c.s.a range 1 ÷ 2,5 mm2 (16 - 14 AWG) 4,8 4,8

Cable ext. Ø range 4,2 ÷ 5,8 mm (0.16” - 0.23” in.) Cable c.s.a range 4 ÷ 6 mm2 (12 - 10 AWG) 6,4 6,4

Cable ext. Ø range 5,8 ÷ 8 mm (0.23” - 0.31” in.) Cable c.s.a range 10 ÷ 16 mm2 (8 - 6 AWG) 9,5 9,5

Cable ext. Ø range 8 ÷ 11 mm (0.31” - 0.43” in.) Cable c.s.a range 25 ÷ 35 mm2 (4 - 2 AWG)

Cable ext. Ø range 11 ÷ 17 mm (0.43” - 0.66” in.) Cable c.s.a range 35 ÷ 50 mm2 (2 - 1/0 AWG) Cable ext. Ø range 17 ÷ 23 mm (0.66” - 0.90” in.) Cable c.s.a range 50 ÷ 120 mm2 (1/0 - 4/0 AWG) Cable ext. Ø range 23 ÷ 36 mm (0.90” - 1.42” in.) Cable c.s.a range 120 ÷ 240 mm2 (250- 500 MCM) Cable ext. Ø range 23÷ 48 mm (1.06” - 1.90” in.) Cable c.s.a range 240 ÷ 400 mm2 (500 - 800 MCM)

It is advisable to select the tubing size based on the actual external diameter of the cable rather than its indicative c.s.a, due to variations in insulation thickness and conductor format.

·3/5·



PRODUCT DATA SHEET

PDS B72_E

H2

HEAT-SHRINKABLE TUBING ladder-printable on both sides

LADDER

with ROLLY2000TR2 990981 printer and black ribbon TRR-055 842121.

Colour

Cable ext. Ø range 1,6 ÷ 2 mm (0.06” - 0.08” in.) Cable c.s.a range 0,25 ÷ 0,5 mm2 (26 - 20 AWG) Internal Ø before shrinking mm

white

2,4

yellow

2,4

H2-32 white

yellow

H2-48 white

yellow

H2-64 white

yellow

H2-95 white

yellow

H2-127

3,2 3,2

4,8 4,8

6,4 6,4

9,5

19,1

yellow

19,1

yellow

H2-381

25,4

38,1

yellow

38,1

white yellow

25 50 50 25 50

H2-48-25-WH2 H2-48-50-WH2 H2-48-50-WH2BULK H2-48-25-YE2 H2-48-50-YE2

2 1 1 2 1

2.000 1.000 5.000 2.000 1.000

4822 4824 4824 4822 4824

H2-64-25-WH2 H2-64-50-WH2 H2-64-50-WH2BULK H2-64-25-YE2 H2-64-50-YE2

2 1 1 2 1

2.000 1.000 3.000 2.000 1.000

4832 4834 4834 4832 4834

25 50 50 25 50

H2-95-25-WH2 H2-95-50-WH2 H2-95-50-WH2BULK H2-95-25-YE2 H2-95-50-YE2

2 1 1 2 1

1.000 500 2.000 1.000 500

4842 4844 4844 4842 4844

25 50 25 50

H2-127-25-WH2 H2-127-50-WH2 H2-127-25-YE2 H2-127-50-YE2

2 1 2 1

1.000 500 1.000 500

4852 4854 4852 4854

25 50 25 50

H2-190-25-WH2 H2-190-50-WH2 H2-190-25-YE2 H2-190-50-YE2

2 1 2 1

1.000 500 1.000 500

4862 4864 4862 4864

25 50 25 50

H2-254-25-WH2 H2-254-50-WH2 H2-254-25-YE2 H2-254-50-YE2

2 1 2 1

600 300 600 300

4872 4874 4872 4874

25 50 25 50

H2-381-25-WH2 H2-381-50-WH2 H2-381-25-YE2 H2-381-50-YE2

2 1 2 1

100 200 100 200

4882 4884 4882 4884

50 50

H2-508-50-WH2 H2-508-50-YE2

1 1

100 100

4894 4894

Cable ext. Ø range 23÷ 48 mm (1.06” - 1.90” in.) Cable c.s.a range 240 ÷ 400 mm2 (500 - 800 MCM) 50,8 50,8

front

printable side

printable side

25 50 50 25 50

Cable ext. Ø range 23 ÷ 36 mm (0.90” ÷ 1.42” in.) Cable c.s.a range 120 ÷ 240 mm2 (250 - 500 MCM)

white

H2-508

4812 4814 4814 4812 4814

Cable ext. Ø range 17 ÷ 23 mm (0.66 - 0.90 in.) Cable c.s.a range 50 ÷ 120 mm2 (1/0 - 4/0 AWG) 25,4

4802 4804 4802 4804

2.000 1.000 5.000 2.000 1.000

Cable ext. Ø range 11 ÷ 17 mm (0.43” - 0.66” in.) Cable c.s.a range 35 ÷ 50 mm2 (2 - 1/0 AWG)

white

2.000 1.000 2.000 1.000

2 1 1 2 1

Cable ext. Ø range 8 ÷ 11 mm (0.31” - 0.43” in.) Cable c.s.a range 25 ÷ 35 mm2 (4 - 2 AWG) 12,7

SW Code

H2-32-25-WH2 H2-32-50-WH2 H2-32-50-WH2BULK H2-32-25-YE2 H2-32-50-YE2

Cable ext. Ø range 5,8 ÷ 8 mm (0.23” - 0.31” in.) Cable c.s.a range 10 ÷ 16 mm2 (8 - 6 AWG) 9,5

Quantity

25 50 50 25 50

Cable ext. Ø range 4,2 ÷ 5,8 mm (0.16” - 0.23” in.) Cable c.s.a range 4 ÷ 6 mm2 (12 - 10 AWG)

yellow

white

H2-24-25-WH2 H2-24-50-WH2 H2-24-25-YE2 H2-24-50-YE2

Tubes per step 2 1 2 1

Cable ext. Ø range 2,8 ÷ 4,2 mm (0.11” - 0.16” in.) Cable c.s.a range 1 ÷ 2,5 mm2 (16 - 14 AWG)

12,7

H2-254

Code

Cable ext. Ø range 1,8 ÷ 2,8 mm (0.07” - 0.11” in.) Cable c.s.a range 0,5 ÷ 1 mm2 (24 - 18 AWG)

white

H2-190

Pre-cut length mm 25 50 25 50

back

H2-24

It is advisable to select the tubing size based on the actual external diameter of the cable rather than its indicative c.s.a, due to variations in insulation thickness and conductor format. · 4 / 5·

2 1

TUBES PER STEP 25 mm

25 mm

50 mm



PRODUCT DATA SHEET

PDS B72_E

H2

HEAT-SHRINKABLE TUBING continuous-printable on both sides

CONTINUOUS

printable: on one side with ROLLY2000TR1 990980 printer and black ribbon TRR-055 842121; on both sides with ROLLY2000TR2 990981 printer and black ribbon TRR-055 842121.

Colour white

Internal Ø before Cable ext. Ø shrinking mm range mm (in.) 2,4 3,2 4,8 6,4 9,5 12,7 19 25,4 38,1 50,8

yellow

2,4 3,2 4,8 6,4 9,5 12,7 19,1 25,4 38,1 50,8

1,6 ÷ 2 (0.06’’- 0.08’’) 1,8 ÷ 2,8 (0.07’’- 0.11’’) 2,8 ÷ 4,2 (0.11’’- 0.18’’) 4,2 ÷ 5,8 (0.16’’- 0.23’’) 5,8 ÷ 8 (0.23’’- 0.31’’) 8 ÷11 (0.31’’- 0.43’’) 11÷17 (0.43’’- 0.66’’) 17÷ 23 (0.66’’- 0.90’’) 23 ÷ 36 (0.90’’ - 1.42’’) 27 ÷ 49 (1.06’’ - 1.90’’) 1,6 ÷ 2 (0.06’’- 0.08’’) 1,8 ÷ 2,8 (0.07’’- 0.11’’) 2,8 ÷ 4,2 (0.11’’- 0.18’’) 4,2 ÷ 5,8 (0.16’’- 0.23’’) 5,8 ÷ 8 (0.23’’- 0.31’’) 8 ÷11 (0.31’’- 0.43’’) 11÷17 (0.43’’- 0.66’’) 17÷ 23 (0.66’’- 0.90’’) 23 ÷ 36 (0.90’’- 1.42’’) 27 ÷ 49 (1.06’’ - 1.90’’)

Cable c.s.a range mm2 (AWG) 0,25 ÷ 0,5 (26 - 20) 0,5 ÷1 (24 - 18) 1÷ 2,5 (16 - 14) 4÷6 (12 - 10) 10 ÷16 (8 - 6) 25 ÷ 35 (4 - 2) 35 ÷ 50 (2 - 1/0) 50 ÷120 (1/0 - 4/0) 120 ÷ 240 (250-500MCM) 240 ÷ 400 (500-800MCM) 0,25 ÷ 0,5 (26 - 20) 0,5 ÷1 (24 - 18) 1÷ 2,5 (16 - 14) 4÷6 (12 - 10) 10 ÷16 (8 -- 6) 25 ÷ 35 (4 - 2) 35 ÷ 50 (2 - 1/0) 50 ÷120 (1/0 - 4/0) 120 ÷ 240 (250-500MCM) 240 ÷ 400 (500-800MCM)

ROLLY2000TR2 to print on both sides

·5/5·

Code H2-24-WH3 H2-24-WH3-50 H2-32-WH3 H2-32-WH3-100 H2-48-WH3 H2-48-WH3-100 H2-64-WH3 H2-64-WH3-100 H2-95-WH3 H2-95-WH3-100 H2-127-WH3 H2-127-WH3-100 H2-190-WH3 H2-190-WH3-100 H2-254-WH3 H2-254-WH3-100 H2-381-WH3 H2-381-WH3-60 H2-508-WH3 H2-508-WH3-60 H2-24-YE3 H2-24-YE3-50 H2-32-YE3 H2-32-YE3-100 H2-48-YE3 H2-48-YE3-100 H2-64-YE3 H2-64-YE3-100 H2-95-YE3 H2-95-YE3-100 H2-127-YE3 H2-127-YE3-100 H2-190-YE3 H2-190-YE3-100 H2-254-WH3 H2-254-YE3-100 H2-381-YE3 H2-381-YE3-60 H2-508-YE3 H2-508-YE3-60

Continuous Quantity length m 20 1 50 1 20 1 100 1 20 1 100 1 20 1 100 1 15 1 100 1 15 1 100 1 15 1 100 1 15 1 100 1 15 1 60 1 15 1 60 1 20 1 50 1 20 1 100 1 20 1 100 1 20 1 100 1 15 1 100 1 15 1 100 1 15 1 100 1 15 1 100 1 15 1 60 1 15 1 60 1

ROLLY2000TR1 to print on one side

SW Code 7000 7000 7010 7010 7020 7020 7030 7030 7040 7040 7050 7050 7060 7060 7070 7070 7080 7080 7090 7090 7000 7000 7010 7010 7020 7020 7030 7030 7040 7040 7050 7050 7060 7060 7070 7070 7080 7080 7090 7090