http://support.automation.siemens.com/WW/view/en/4017022&td=1
6AV6545-0AA15-2AX0
TOUCH PANEL TP070 5,7" STN-DISPLAY
Technical Data
As of 2008-10-26 Supply voltage Supply voltage permissible range Type of voltage Rated current
DC 24 V DC +18 to +30 V DC 0.24 A
Memory Type of storage Type Memory usable for project data/Options
Flash / RAM 128 kByte Usable memory for user data / Without additional memory for options
Time Clock Type
Software clock, Not battery backed
Configuration Configuration tool 1st configuration package Version Configuration tool Type 2nd configuration package Version Configuring tool Type
MicroWin / TP designer As of Version 1 (must be ordered separately) MicroWin / TP designer Version 1 MicroWin TP designer No
Display Display type Design of the display Size Screen diagonal Resolution (WxH in pixel) Width Height Color type MTBF backlighting (at 25 °C)
STN, 4 Blue levels STN 5,7 Zoll 5.7 " 320 x 240 320 240 Blue levels Approx. 50000 h
Expansions to operator processcommunication DC 24 V direct key module/outputs CPI module
No No
Operating mode Operating elements Operating options Function keys, programmable
Page 1 of 6
Touchscreen Touch None
5/7/2010 3:10:43 PM
http://support.automation.siemens.com/WW/view/en/4017022&td=1
Touchscreen Numeric/alphabetical input hexadecimal keyboard Multi-key operation Connection for mouse/keyboard/barcode reader external mouse external keyboard Connection for barecode reader
analog, resistive Yes / No Yes No -/-/-
Degree of protection Front IP (at front) Rear IP (rear)
IP65 IP65 IP20 IP20
Certifications & Standards Certifications
CE, FM Class I Div. 2, UL, CSA, cULus
Ambient conditions Mounting position maximum permissible angle of incliniation without external ventilation max. relative humidity (in %)
Vertical +/- 35° 85 %
Temperature Operation (vertical installation) Operation (max. tilt angle) Transport, storage
0 to +50°C 0 to +40°C -20 to +60°C
Type of output Info LED Power LED Error LED LED colors
No No No None
interfaces Interfaces Number of interfaces/according to RS 485 Transmission rate, max. PC card slot CF card slot Multi Media Card slot USB Ethernet Special interfaces
1 x RS-485 (Max. 0,0192 Mbit/s) 1 0.0192 Mbit/s No No No No No No
Operating systems Operating system
Windows CE
other free hHotline Warranty period
Yes 1 Jahr(e)
Processor Processor Processor type
RISC 32Bit RISC 32Bit
Drives Design of drive/storage medium, CD-ROM Design of drive/storage medium, diskette Design of drive/storage medium, hard disk
No No No
Functionality under ProTool Flush display
Page 2 of 6
Yes
5/7/2010 3:10:43 PM
http://support.automation.siemens.com/WW/view/en/4017022&td=1
Help system Number of info. texts Memory requirement for first unit Memory requirement for each additional unit Number of tooltips Memory requirement for first unit Memory requirement for each additional unit Status/control
No 0 10 Byte 10 Byte 0 10 Byte 10 Byte Not possible
Message system Number of operating messages
0
Recipes Memory requirement for first unit Memory requirement for each additional unit
0 Byte 0 Byte
Number of process images Number of process images Memory requirement for first unit Memory requirement for each additional unit Number of variables Number of variables of Date & Time type Number of variables of internal variable type Number of initial values Limit values
30 11176 Byte 72 Byte 50 0 50 0 No
Image elements Text objects Number of fields per screen Number of variables per screen Permanent window/default Image selection via PLC Index of images Start image configurable Image number in the PLC Return Graphics object Number of icons Memory requirement for first unit Memory requirement for first unit Memory requirement for each additional unit Memory requirement for each additional unit Number of screen filling icons Memory requirement for first unit Memory requirement for first unit Memory requirement for each additional unit Memory requirement for each additional unit dynamic objects Memory requirement for first unit Memory requirement for each additional unit Number of bars per chart Direction Limit value lines Number of alphanumerical fields Number of alphanumerical fields per screen Memory requirement for first unit Memory requirement for each additional unit
Page 3 of 6
80 Text elements 20 10 N No No Yes Yes No Bitmaps, Icons, Icon (screen filling) 20 264 Byte 264 Byte 208 Byte 208 Byte 1 7240 Byte 7240 Byte 5280 Byte 5280 Byte Bar graphs 0 Byte 0 Byte 3 vertical / horizontal No 50 10 648 Byte 192 Byte
5/7/2010 3:10:43 PM
http://support.automation.siemens.com/WW/view/en/4017022&td=1
Number of numerical fields Number of numerical fields per screen Memory requirement for first unit Memory requirement for each additional unit Number of date and time fields Memory requirement for first unit Memory requirement for each additional unit Number of password fields Memory requirement for first unit Memory requirement for each additional unit Number of sliders per screen Memory requirement for first unit Memory requirement for each additional unit Numbr of analog indicators per image Memory requirement for first unit Memory requirement for each additional unit Number of visible switches per project Number of visible switches per screen Memory requirement for first unit Memory requirement for each additional unit Number of invisible switches per screen Memory requirement for first unit Memory requirement for each additional unit Number of status switches per project Memory requirement for first unit Memory requirement for each additional unit Memory requirement for first unit Memory requirement for each additional unit
50 10 648 Byte 192 Byte 0 0 Byte 0 Byte 0 0 Byte 0 Byte 0 0 Byte 0 Byte 0 0 Byte 0 Byte 20 0 0 Byte 0 Byte 0 0 Byte 0 Byte 20 0 Byte 0 Byte 0 Byte 0 Byte
Lists Memory requirement for first unit Memory requirement for first unit Memory requirement for each additional unit Memory requirement for each additional unit
0 Byte 0 Byte 0 Byte 0 Byte
Data medium support Data medium support
None
Recording Logging/Printing
Not possible
Fonts Keyboard character sets
US American
Languages Number of online languages Number of online languages per project Memory requirement for first unit Memory requirement for each additional unit Configuration languages Fonts
1 5 10 Byte 10 Byte D, GB, F, I, E Tahoma, all freely scalable
Transfer (Upload/Download) Transfer of configuration
serial
Download optional software Operating system update
Y Y
Process coupling Connection to controller
Page 4 of 6
S7-200, See section "System Links"
5/7/2010 3:10:43 PM
http://support.automation.siemens.com/WW/view/en/4017022&td=1
S5 serial PROFIBUS DP S7-200 PPI (point-to-point) PPI network MPI PROFIBUS DP S7- 300/400 MPI PROFIBUS DP PROFINET IO TI 505 Point-to-point Network Allen Bradley (DF1) Point-to-point Network Allen Bradley (DH485) Point-to-point Network Mitsubishi (FX) Point-to-point Network Mitsubishi (MP4) Point-to-point Network Telemecanique (ADJUST) Point-to-point Network Telemecanique (Uni-Telway) Point-to-point Network OMRON (LINK/Multilink) Point-to-point Network Modicon (Modbus) Point-to-point Network GE-Fanuc (SNP) Point-to-point Network
No No No Yes No No Yes No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No
Functions Key repeat TAB sequence Calculating functions Animate Menu tree editor Unit switchover Booting via external memory
No No Yes No No No No
Service tools/configuration aids Touch calibration Backup/Restore
Page 5 of 6
Yes No
5/7/2010 3:10:43 PM
http://support.automation.siemens.com/WW/view/en/4017022&td=1
Simulation Language tool System messages Edit Device switchover Delta transfer Monitoring the battery, memory,... Trace (operation archive)
No No No No No No No
Expandability/openness Open Platform Program (OPP)
No
Mechanics Type of housing (front) Mounting technology
Plastic Clamp terminals
Dimensions Front of enclosure (W x H) Mounting cutout/Device depth (W x H/D) in mm
212 mm x 156 mm 198 mm x 142 mm / 45 mm Device depth
Weights Weight
0.7 kg
© Siemens AG 2010 - Corporate Information - Privacy Policy - Terms of Use
Page 6 of 6