www.motralec.com /
[email protected] / 01.39.97.65.10
Fan Solutions for smoke extraction
Issue 4.1 EN
www.motralec.com /
[email protected] / 01.39.97.65.10
You have to understand fire to master smoke extraction
Conflagration gases and fumes emitted by burning 10 kg of each material
Find out about our range of modern smoke extraction systems in this catalogue and see for yourself what good value intelligent smoke extract fans from Nicotra Gebhardt are. And above all: act on it before it is too late! We would be happy to advise you.
20.000 15.000 10.000
er
VC dP
Har
ood
pap
se
Cel
lulo
ard
lyw
Birc
hp
ard
dbo Har
um
pbo Chi
Lin
ole
e
P
len
GR
opy
ypr Pol
um
am
role Pet
e fo
Fle
xibl
ting hea
ne ose
Foa
mr
ubb
er
oil
5.000
Ker
We can offer you the world’s largest range of mechanical smoke extraction solutions – compiled in this brand new SafeAir catalogue. With our wall, roof, radial, axial and pulse fans, we master every form of smoke extraction, whatever the application. We thereby ensure maximum safety throughout any building – from the underground car park to the roof – and comply with all the statutory norms for building fire protection.
25.000
Amount of smoke [m3/h]
Perfect smoke extraction in the case of fire not only demands absolute understanding of the techniques used – it also calls for an understanding of the nature of fire and the flow of fumes. Nicotra Gebhardt sets standards in both aspects – by using CFD to simulate the flow of smoke, for example.
www.motralec.com /
[email protected] / 01.39.97.65.10
Safe smoke extraction solutions from the cellar to the roof!
1
4 2 3
10 12
11
12
5
6
12 9
12
10
7
8
12
H
1 genovent smoke extractor roof fans, RDM 57
7 AGM Jetfan prevent smoke extractor pulse fan
2 genovent smoke extractor roof fan, RDM 56
8 RGM Jetfan prevent smoke extractor pulse fan
Smoke extraction
3 Radial smoke extractor fan, REM BU/RER 13; 17
9
Supply air
4 2 Centrifugal fans for supply air
10 Optical smoke detector
5 SLCS axial smoke extractor fan
11 Duct – F 90
6 RWM 57 smoke extractor wall fan
12 Smoke dampers
Smoke detector switchgear (out of fire zone)
H
Headroom according to garages regulation
www.motralec.com /
[email protected] / 01.39.97.65.10
l
•
• •
• • •
•
•
5
3
8 4 10
7
ula ting
el
•
AGM: Thrust up to 52 N RGM: Thrust up to 75 N
•
•
• •
AGM: Thrust up to 52 N RGM: Thrust up to 75 N
•
• •
As necessary
I ns
s te te d
•
5
5
• • •
•
4
5
C oa
• •
5
4
c as
te e
•
5
3
ds
• • •
4 5
va n is e
• • •
2
5
G al
•
6 4
Alu min ium
ive t dr
•
+40 °C
SLCS AGM | RGM
B el
Dir
ect
ha
dr i v e
rg
e
120
sc Di
C– 0° 60
C– 0°
min
min 120
120 40
0°
C–
³/h 30
0m 00
³/h
150 .
0m .0 0
³/h
65
00 57.
00
0m
0m
³/h
³/h 37.
00
0m
/h 31.
m³ 00 14. 0
RDM 56 | 57 RWM 57 REM BU | BI RER 13 | 17
• • •
• • • • •
1
Material
• • • •
• • • • • • • •
AGM | RGM [CO] PPSP System
Drive type
ing
Conveying medium
min
Flow rate
• •
www.motralec.com /
[email protected] / 01.39.97.65.10
Smoke extract fans
RDM
RWM
REM
RER
Smoke Extract–Roof Fan with direct drive
Smoke Extract–Wall Fan with direct drive
Smoke Extract–Centrifugal Fan with direct drive
Smoke Extract–Centrifugal Fan with belt drive
Vertical discharge, motor separated from airflow, with outlet flaps, snow load class SL 1000 RDM 56 +400°C – 120 min. RDM 57 +600°C – 120 min.
Horizontal discharge, for wall installation, motor separated from airflow
single inlet, inlet and discharge sides with flange for duct system, motor separated from airflow. REM BU +400°C – 120 min. without insulating housing. REM BI +400°C – 120 min. with insulating housing.
single inlet, inlet and discharge sides with flange for duct system, motor separated from airflow. RER 13 +400°C – 120 min. welded, coated. RER 17 +400°C – 120 min. lock-seamed, galvanised.
SLCS
AGM
RGM
PPSP - Systems
Smoke Extract–Axial Fan with direct drive
Smoke Extract–Axial Fan with direct drive
Smoke Extract–Radial Fan with direct drive
Positive Pressure Smoke Protection – Systems
RWM 57 +600°C – 120 min.
For horizontal and vertical installation, motor in airflow. SLCS +300°C – 120 min. SLCS +400°C – 120 min. on request.
Axial Jet fan based on the pulse fan principle, motor in airflow. AGM 01/02 +300°C – 120 min. not reversible. AGM 11/12 +300°C – 120 min. reversible. AGM 06/16 for ventilation of CO gases and continuous standard ventilation up to +40 °C. Not reversible and reversible models.
Radial Jet fan based on the pulse fan principle, motor in airflow. RGM 91 +300°C – 120 min. REM 96 for ventilation of CO gases and continuous standard ventilation up to +40 °C.
For indoor stairwells, corridors and emergency tunnels.
EN-BR2-SafeAir-4.1 – PDF1-04.2012
www.motralec.com /
[email protected] / 01.39.97.65.10
Nicotra Gebhardt Germany
Nicotra Gebhardt Italy
Nicotra Gebhardt GmbH Gebhardtstrasse 19-25 74638 Waldenburg Germany Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail
[email protected]
Nicotra Gebhardt S.p.A Via Modena, 18 24040 Zingonia (BG) Italy Phone +39 035 873 111 Fax +39 035 884 319 E-mail
[email protected]
nicotra-gebhardt.com