Fan Solutions for smoke extraction

www.motralec.com / [email protected] / 01.39.97.65.10 Fan Solutions for smoke extraction Issue 4.1 EN www.motralec.com / service-com...
Author: Nathan Ryan
1 downloads 0 Views 1MB Size
www.motralec.com / [email protected] / 01.39.97.65.10

Fan Solutions for smoke extraction

Issue 4.1 EN

www.motralec.com / [email protected] / 01.39.97.65.10

You have to understand fire to master smoke extraction

Conflagration gases and fumes emitted by burning 10 kg of each material

Find out about our range of modern smoke extraction systems in this catalogue and see for yourself what good value intelligent smoke extract fans from Nicotra Gebhardt are. And above all: act on it before it is too late! We would be happy to advise you.

20.000 15.000 10.000

er

VC dP

Har

ood

pap

se

Cel

lulo

ard

lyw

Birc

hp

ard

dbo Har

um

pbo Chi

Lin

ole

e

P

len

GR

opy

ypr Pol

um

am

role Pet

e fo

Fle

xibl

ting hea

ne ose

Foa

mr

ubb

er

oil

5.000

Ker

We can offer you the world’s largest range of mechanical smoke extraction solutions – compiled in this brand new SafeAir catalogue. With our wall, roof, radial, axial and pulse fans, we master every form of smoke extraction, whatever the application. We thereby ensure maximum safety throughout any building – from the underground car park to the roof – and comply with all the statutory norms for building fire protection.

25.000

Amount of smoke [m3/h]

Perfect smoke extraction in the case of fire not only demands absolute understanding of the techniques used – it also calls for an understanding of the nature of fire and the flow of fumes. Nicotra Gebhardt sets standards in both aspects – by using CFD to simulate the flow of smoke, for example.

www.motralec.com / [email protected] / 01.39.97.65.10

Safe smoke extraction solutions from the cellar to the roof!

1

4 2 3

10 12

11

12

5

6

12 9

12

10

7

8

12

H

1 genovent smoke extractor roof fans, RDM 57

7 AGM Jetfan prevent smoke extractor pulse fan

2 genovent smoke extractor roof fan, RDM 56

8 RGM Jetfan prevent smoke extractor pulse fan

Smoke extraction

3 Radial smoke extractor fan, REM BU/RER 13; 17

9

Supply air

4 2 Centrifugal fans for supply air

10 Optical smoke detector

5 SLCS axial smoke extractor fan

11 Duct – F 90

6 RWM 57 smoke extractor wall fan

12 Smoke dampers

Smoke detector switchgear (out of fire zone)

H

Headroom according to garages regulation

www.motralec.com / [email protected] / 01.39.97.65.10

l



• •

• • •





5

3

8 4 10

7

ula ting

el



AGM: Thrust up to 52 N RGM: Thrust up to 75 N





• •

AGM: Thrust up to 52 N RGM: Thrust up to 75 N



• •

As necessary

I ns

s te te d



5

5

• • •



4

5

C oa

• •

5

4

c as

te e



5

3

ds

• • •

4 5

va n is e

• • •

2

5

G al



6 4

Alu min ium

ive t dr



+40 °C

SLCS AGM | RGM

B el

Dir

ect

ha

dr i v e

rg

e

120

sc Di

C– 0° 60

C– 0°

min

min 120

120 40



C–

³/h 30

0m 00

³/h

150 .

0m .0 0

³/h

65

00 57.

00

0m

0m

³/h

³/h 37.

00

0m

/h 31.

m³ 00 14. 0

RDM 56 | 57 RWM 57 REM BU | BI RER 13 | 17

• • •

• • • • •

1

Material

• • • •

• • • • • • • •

AGM | RGM [CO] PPSP System

Drive type

ing

Conveying medium

min

Flow rate

• •

www.motralec.com / [email protected] / 01.39.97.65.10

Smoke extract fans

RDM

RWM

REM

RER

Smoke Extract–Roof Fan with direct drive

Smoke Extract–Wall Fan with direct drive

Smoke Extract–Centrifugal Fan with direct drive

Smoke Extract–Centrifugal Fan with belt drive

Vertical discharge, motor separated from airflow, with outlet flaps, snow load class SL 1000 RDM 56 +400°C – 120 min. RDM 57 +600°C – 120 min.

Horizontal discharge, for wall installation, motor separated from airflow

single inlet, inlet and discharge sides with flange for duct system, motor separated from airflow. REM BU +400°C – 120 min. without insulating housing. REM BI +400°C – 120 min. with insulating housing.

single inlet, inlet and discharge sides with flange for duct system, motor separated from airflow. RER 13 +400°C – 120 min. welded, coated. RER 17 +400°C – 120 min. lock-seamed, galvanised.

SLCS

AGM

RGM

PPSP - Systems

Smoke Extract–Axial Fan with direct drive

Smoke Extract–Axial Fan with direct drive

Smoke Extract–Radial Fan with direct drive

Positive Pressure Smoke Protection – Systems

RWM 57 +600°C – 120 min.

 











 



 



 





  

For horizontal and vertical installation, motor in airflow. SLCS +300°C – 120 min. SLCS +400°C – 120 min. on request.

Axial Jet fan based on the pulse fan principle, motor in airflow. AGM 01/02 +300°C – 120 min. not reversible. AGM 11/12 +300°C – 120 min. reversible. AGM 06/16 for ventilation of CO gases and continuous standard ventilation up to +40 °C. Not reversible and reversible models.

Radial Jet fan based on the pulse fan principle, motor in airflow. RGM 91 +300°C – 120 min. REM 96 for ventilation of CO gases and continuous standard ventilation up to +40 °C.



For indoor stairwells, corridors and emergency tunnels.

EN-BR2-SafeAir-4.1 – PDF1-04.2012

www.motralec.com / [email protected] / 01.39.97.65.10

Nicotra Gebhardt Germany

Nicotra Gebhardt Italy

Nicotra Gebhardt GmbH Gebhardtstrasse 19-25 74638 Waldenburg Germany Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail [email protected]

Nicotra Gebhardt S.p.A Via Modena, 18 24040 Zingonia (BG) Italy Phone +39 035 873 111 Fax +39 035 884 319 E-mail [email protected]

nicotra-gebhardt.com