DXN
Features and Ratings
p. 178
Certifications and Testing
p. 179
Operation
p. 180
DXN20
p. 181
DXN30
p. 183
DXN60
p. 185
Dimensions
p. 187
Hazardous location rated plugs and receptacles DXN Series plugs and receptacles are convenient, lightweight devices that are safe for use in hazardous environments such as refineries or silos where exposure to flammable gas or dust is a concern. The DXN’s compact size and durable construction makes them easy to handle and well suited for in-line connections of electrical equipment. The DXN’s dead front construction assures electrical safety by preventing user access to live parts. IP66+IP67 ratings are achieved as soon as the plug and receptacle are mated, making them the perfect choice for wet or dusty environments.
Main Advantages u u 177
u
Easy to handle due to compact, lightweight design Available in in-line and wall/panel mounted configurations CSA, ATEX and IECEx rated for use in Zones 1 and 2 (gas) and Zones 21 and 22 (dust).
Product Features
Operating Instructions
Pushbutton Pawl / OFF Button Spring-Loaded Butt-Style Contacts
Provides quick, safe and easy current interruption.
Silver-Nickel Contacts
Ensures optimal contact force and superior electrical performance over thousands of operations.
Silver-nickel contact material provides superior conductivity, durability and corrosion resistance. Hazardous Location Termination Areas Includes enhanced creepage and clearance distances and specially designed terminals to ensure perfect and permanent clamping.
1 To connect, align the red dots, push the plug partially in, then turn clockwise slightly to line up the latch with the catch.
Explosion Proof Arc Chamber Withstands internal pressure due to gas/dust ignited by arcing and isolates it from the outside environment. Explosion Proof Flame Path
Casing Self-extinguishing, non-static, material provides outstanding resistance to mechanical abuse and chemicals.
Lid When closed, the lid maintains IP66+IP67 protection for the receptacle after removal of the plug.
Dissipates internal pressure created during arcing while also preventing any associated ignition sources from reaching the surrounding atmosphere.
2 Push the plug fully home until it is held in place by the latch The circuit is now closed.
General Ratings Amperage
20 to 60A
Voltage
600 VAC*
Frequency
50-400 Hz
Horsepower
1/4 to 20 hp
Environmental
IP66+IP67
Temperature
min -40°F/max 140°F
Highlighted Feature Dead Front
3 To disconnect, depress the latch and pull the plug simultaneously. This breaks the circuit. The plug contacts are now dead.
* DXN30 and DXN60 devices are 550VAC if ordered with
optional auxiliary contacts.
Hazardous Duty Listings Class I, Zone 1 Ex IIC T*, Class II, Zone 21 Class I, Zone 1 AEx, de IIC T*
ATEX II 2 G/D Ex ed IIC T* Ex ED A2I T*
Class I Division 2 Gr A, B, C, D
The dead front on the DXN receptacle provides protection from accidental tool and wire insertion.
Class II Division 2 Gr E, F, G
4
* See temperature tables in product sections.
See following page for additional ratings detail.
Plug & Receptacle Listings Category Plugs and Receptacles
CSA IEC C22.2 No. 182.1
Rotate 30° counterclockwise and then withdraw the plug. The safety shutter prevents access to live parts.
60309-1
CE ratings available upon request 178
HAZARDOUS LOCATION
CSA
DXN Certifications Hazardous Duty Certification (example) DXN’s have CSA and ATEX certifications for use in hazardous locations.
CSA Class I, Zone 1, Ex de IIC T6*, Class II, Zone 21 Class I, Zone 1, AEx de IIC T6* Class I Division 2 Gr A,B,C,D Class I – Indicates suitability for use in applications where flammable Gases, Vapors, or Mists may be present. Zone I – Indicates suitability for use in applications where an explosive environment is likely to occur. Division 2 – Indicates suitability for use where exposure to the hazard occurs under abnormal conditions. GR A,B,C,D – Indicates suitability for use in areas that may contain Acetylene, Hydrogen, Ethylene, or Propane. Class II Division 2 Gr E,F,G Class II – Indicates suitability for use in applications where explosive dust atmosphere may occur. Division 2 – Indicates suitability for use where hazard exposure occurs under abnormal conditions. GR E,F,G – Indicates suitability for use in areas where Magnesium, Coal or Grain dust may occur. CSA certification based on IEC 60079-0, 60079-1, 60079-7
ATEX and IECEx II 2 G/D Ex de IIC T6* II – Indicates suitability for installation in surface applications (as opposed to underground mine applications). 2 – Indicates suitability for use where a high level of protection is required and where the presence of an explosive atmosphere is likely to occur (Zone 1 and Zone 21 environments). G/D – Indicates suitability for installation in areas that may contain flammable gases, vapors/mists, or dusts. T85°C* – Indicates a maximum surface temperature of the product of 85°C, at 40°C ambient. Ex de – Indicates that explosion protection is provided with (e) increased safety in the conductor termination area, and (d) flame proof chambers for making and breaking the current that can withstand the pressure of internal ignition and that prevent arcs, flame or other ignition events from being communicated to the surrounding atmosphere. IIC – Indicates suitability for installation in areas where exposure to any type of gas, including the most dangerous subdivision C gases may occur. T6* – Temperature class – the maximum product surface temperature is 185°F (85°C) for ambient temperature of 104°F (40°). ATEX certification was performed by LCIE. * Temperature ratings vary depending on product and ambient temperature. See specific product section for temperature ratings.
Electrical Performance Testing Model
179
Mechanical Endurance
Key Performance Tests Passed Electrical Overload Temperature Endurance1 Testing2 Rise (max)
Dielectric Test
DXN20
-
5000 Operations
50 Operations
30°C
2 x V (rated) + 1000V
DXN30
1000 Cycles
1000 Operations
50 Operations
30°C
2 x V (rated) + 1000V
DXN60
1000 Cycles
1000 Operations
50 Operations
30°C
2 x V (rated) + 1000V
1
@ 100% of rated current and voltage and 0.6 power factor
2
@125% of rated current, 110% of rated voltage, & 0.6 power factor
DXN Operation Arcing is a natural occurrence when electrical contacts make and break under load. The purpose of a hazardous duty product is to prevent arcing from igniting hazardous gases or dusts present in the atmosphere into an explosion that may cause personal injury or damage to facilities and equipment. The DXN accomplishes this with specially designed flame-proof arc chambers. The arc chambers are sized to minimize the amount of atmospheric gas or air/dust mixture that may ignite during arcing and are built to contain this internal mini-explosion and withstand the pressure that it generates. The length and width of the flame-proof pathways are very precisely designed to provide for the effective dissipation of the pressure, while also ensuring that the arcing and internal ignitions of gases or air/dust mixture in the arc chamber are totally isolated from the surrounding atmosphere.
1
Flame-Proof Paths
Arc Chamber
2
1 When the plug and receptacle are connected, the
flameproof arc chamber is completed with pressure relief/arc extinguishing pathways between the outer diameter of the plug contact and its associated contact hole in the safety shutter and between the main interior component and receptacle contact base.
2 DXN’s are current interrupting rated devices. They can
safely make and break under full load and also during moderate overload situations. During the making or breaking of the contacts, the arc chamber completely contains any ignitions of gas or dust due to arcing and the flame-proof pathways dissipate the pressure.
3
3 As the plug is being inserted or removed, the flame-proof
arc chamber and pathways are maintained. This ensures continuous hazardous duty protection and the safety of the user.
4 When the plug and receptacle are disconnected, the
4
receptacle maintains a flame-proof chamber. In this case, the flame-proof pathway exists between the safety shutter and the main interior component. The shutter also prevents access to live parts, providing users with the safety of a dead front. The plug must be inserted into the safety shutter and be rotated in order to access the receptacle contacts.
HAZARDOUS LOCATION
180
DXN – 20A
DXN20
Hazardous Location Plugs & Receptacles Receptacle (female)
Ratings
Inlet (male)
• Voltage 480 VAC • Current Interruption Capability For current interrupting (AC) • Horsepower Ratings 120V 1Ø 1/2 hp 240V 3Ø 2 hp 480V 3Ø 5 hp 600V 3Ø 5 hp
!
• Environmental Ratings IP66+IP67
Receptacles & Inlets must be mounted to a DXN handle, angle or wall box.
Standard DXN20 lid opens to 120° Hazardous Location rating terminology and labeling is different for CE marked products – For international configurations (CE) visit meltric.com/international-catalog or contact customer service.
Part # Part # Voltage Polarity Voltage Polarity Poly Poly
• Wiring Capacity Min 16 AWG Max 10 AWG * Based on THHN wire sizes
1P+N+G 22-14165 1P+N+G 22-18165 120V 120V
• Listings CSA, IECEx, ATEX
125V 125V 1P+N+G 22-14075 1P+N+G 22-18075
customer service
3P+G 22-14163 3P+G 22-18163 208V 208V
• DXN20 Ratings Label
3P+N+G 22-14167 3P+N+G 22-18167 208V 208V
2P+G 22-14162 2P+G 22-18162 208V 208V
* For CE rated devices, contact
-40°C ≤Ta ≤+60°C Class I Zone1 Ex de IIC T5 DIP A21 T90°C Class I Zone1 AEx de IIC T5 tD 21 T90°C Class I div 2 Gr IIC (A,B,C,D) Class II div 2 Gr E,F,G cCSAus 208161-1144106X
The CSA ratings are applicable for
USA and Canada
250V 250V 2P+G 22-14072 2P+G 22-18072 250V 250V 3P+G 22-14073 3P+G 22-18073 250V 250V 2P+N+G 22-14076 2P+N+G 22-18076 277V 277V 1P+N+G 22-14045 1P+N+G 22-18045 480V 480V 2P+G 22-14042 2P+G 22-18042
3P+G 22-14043 3P+G 22-18043 480V 480V
• Temperature Table Ambient Temperature Gas
480V 480V 3P+N+G 22-14047 3P+N+G 22-18047
Dust
-40°F < Ta < 104°F
T6
T70°C
-40°F < Ta < 140°F
T5
T90°C
600V 600V 2P+G 22-14142 2P+G 22-18142 600V 600V 3P+G 22-14143 3P+G 22-18143 600V 600V 3P+N+G 22-14147 3P+N+G 22-18147
Devices rated for hazardous locations are not returnable. Receptacle Options
Main Options 5/16” hole
Padlock Pawl
Part #
Padlock Pawl
Recept # - 843
Metal Pawl on Poly Receptacle
Recept # - 924
Closed Lid Configuration
Recept # - R
180˚ Lid Opening
Recept # - 180
Inlet Options No Lockout Hole
Part # Inlet # - A155
Normally Closed Lid Configuration (unlatched)
180° Lid Opening
How to Order
Receptacle and Inlet (see above)
(for connecting to wall mounted inlets)
+ See pgs 205-214 for detailed information on these options 181
+
Accessories Angle, Handle, etc are interchangeable (see opposite page)
DXN20 Order Example: To order a padlock pawl on a receptacle, add -843 to the part number. DXN20 Poly receptacle 3P+G=22-14043-843 Appropriate accessory part numbers must also be included on the order.
DXN20
Installation Accessories Handles
For Zone 1/21 applications
For use with Class I/II Division 2 or Zone 1 /21 fittings
Cable Range Poly Handle w/Bushing+
Angles
Nylon 30° Angle
NPT Poly Handle w/NPT***
.31 - .51
22-1A013-20P+
1/2”
22-1A013-12***
.51 - .75
22-1A013-25P+
3/4”
22-1A013-34***
.67 - .98
22-1A013-32P
DXN accessories are not returnable.
22-1A027
+
+ ATEX rated for use in Zone 1/21, not listed for Class I or II, Division 2.
*** For use in Class I or II, Division 2 or Zone 1/21 depending on fitting used. Fitting manufactured by others.
Wall Boxes
Cable Range
NPT
.312 - .625
1/2”
.438 - .812
3/4”
NPT sizes are determined by the cable diameter and third party cord grip.
NPT
82.3 in 3+ Cable Range
Poly 70° ++ Wall Box
NPT
.393 - .551
22-1AB58
4.5 in 3+ NPT
4.5 in 3+
75.0 in3+
Poly 30°* Wall Box
Poly 30°** Wall Box
Poly 70°*** Alum Wall Box
1/2”
22-1A023-12-T
22-1A023-12-B
22-1A058-12
3/4”
22-1A023-34-T
22-1A023-34-B
22-1A058-34
1”
–
–
1 1/4”
–
–
22-1A058-114
1 1/2”
–
–
22-1A058-112
Accessory Spotlight Receptacle Lockout Pin
22-1A058-1
+ Interior volume with receptacle installed. ++ Poly cord grip is located on the top of box.
* NPT thread on top. ** NPT thread on bottom. For bottom cord entry, rotate the box 180°. *** NPT is drilled on top of aluminum box as standard. For NPT on side only, add an “L” suffix. To switch from top to bottom or left to right the box can be rotated 180°.
Miscellaneous Accessories
* Set of Two (2)
NPT Guidelines
A 5/16” lockout pin can be ordered to securely lockout receptacles that include the ‘padlockable pawl’ option. Alternatively the user can utilize a lock with a 5/16” shank. Locks with smaller shanks will NOT securely lockout a receptacle pawl.
Order Example A typical order should include an inlet part number, a receptacle part number AND the matching handles, angles or other required accessories.
For Male Devices Only
Finger Drawplates
Protective Cap
Receptacle + Lockout Pin
61-1A346
22-1A426
LP-843
* Recommended for cord to cord assembly applications, for easier connector closure. + Requires Padlockable Pawl option (-843) on receptacle.
NEiW ngs
HP rated DXN20 AMPS
VAC (Max) @ 60 Hz
Phases
HP Rating
20 20 20 20
120V
1Ø 3Ø 3Ø 3Ø
1/2 hp 2 hp 5 hp 5 hp
480V 600V
HAZARDOUS LOCATION
Rat
DXN20 Horsepower Ratings
240V
Male Inlet with Handle (Plug) 22-18043 + 22-1A013-20P
• HP ratings are based on CSA certification
Female Receptacle with Wall Box 22-14043 + 22-1A023-12-T 182
DXN – 30A
DXN30
Hazardous Location Plugs & Receptacles Receptacle (female)
Ratings
Inlet (male)
• Voltage 600 VAC • Current Interruption Capability For current interrupting (AC) • Horsepower Ratings 120V 1Ø 1 hp 240V 3Ø 5 hp 480V 3Ø 10 hp 600V 3Ø 15 hp
Receptacles & Inlets must be mounted to a DXN handle, angle or wall box.
• Environmental Ratings IP66+IP67 • Wiring Capacity Min 14 AWG Max 6 AWG Aux Contacts - Max 10 AWG * Based on THHN wire sizes
Standard DXN30 lid opens to 120° Hazardous Location rating terminology and labeling is different for CE marked products – For international configurations (CE) visit meltric.com/international-catalog or contact customer service.
Part # Part # Voltage Polarity Voltage Polarity Poly Poly 1P+N+G 22-34165 1P+N+G 22-38165 120V 120V 125V 125V 1P+N+G 22-34075 1P+N+G 22-38075
• Listings CSA, IECEx, ATEX
2P+G 22-34162 2P+G 22-38162 208V 208V
* For CE rated devices, contact customer service
3P+G 22-34163 3P+G 22-38163 208V 208V 3P+N+G 22-34167 3P+N+G 22-38167 208V 208V
• DXN30 Ratings Label
250V 250V 2P+G 22-34072 2P+G 22-38072
-40°C ≤Ta ≤+60°C Class I Zone1 Ex de IIC T4 DIP A21 T98°C Class I Zone1 AEx de IIC T4 tD 21 T98°C Class I div 2 Gr IIC (A,B,C,D) Class II div 2 Gr E,F,G cCSAus 208161-1144106X
The CSA ratings are applicable for
250V 250V 3P+G 22-34073 3P+G 22-38073 250V 250V 2P+N+G 22-34076 2P+N+G 22-38076 277V 277V 1P+N+G 22-34045 1P+N+G 22-38045 480V 480V 2P+G 22-34042 2P+G 22-38042
USA and Canada
3P+G 22-34043 3P+G 22-38043 480V 480V
• Temperature Table
480V 480V 3P+N+G 22-34047 3P+N+G 22-38047
Ambient Temperature Gas
Dust
600V 600V 2P+G 22-34142 2P+G 22-38142
-40°F < Ta < 104°F
T6
T57°C
3P+G 22-34143 3P+G 22-38143 600V 600V
-40°F < Ta < 140°F
T5
T77°C
3P+N+G 22-34147 3P+N+G 22-38147 600V 600V
Devices rated for hazardous locations are not returnable.
Main Options 5/16” hole
Receptacle Options
Padlock Pawl
Normally Closed Lid Configuration (unlatched)
180° Lid Opening
Part #
With 2 Auxiliary/Pilot Contacts* Inlet # - 972
Padlock Pawl
Recept # - 843
No Lockout Hole
Metal Pawl on Poly Receptacle
Recept # - 924
Closed Lid Configuration
Recept # - R
180˚ Lid Opening
Recept # - 180
* Not available with 600V devices, use -972-S74 for 550VAC.
Inlet # - A155
Option Spotlight 2 Auxiliary Contacts
How to Order
Receptacle and Inlet (see above)
+
183
Inlet Options
With 2 Auxiliary/Pilot Contacts* Recept # - 972
(for connecting to wall mounted inlets)
See pgs 205-214 for detailed information on these options
Part #
+
Accessories Angle, Handle, etc are interchangeable (see opposite page)
2 auxiliary/pilot contacts can be added for signal or control circuits. Avoid the need for separate connectors. To order add -972 to the inlet and receptacle part numbers.
DXN30
Installation Accessories Handles
For Zone 1/ 21 applications
For use with Class I/II Division 2 or Zone 1 /21 fittings
Cable Range Poly Handle w/Bushing+
Angles
Nylon 30° Angle
NPT Poly Handle w/NPT***
.31 - .51
22-3A013-20P+
3/4”
22-3A013-34***
.51 - .75
22-3A013-25P+
1”
22-3A013-1***
.67 - .98
22-3A013-32P
.95 - 1.26
22-3A013-40P+
DXN accessories are not returnable.
22-3A027
+
+ ATEX rated for use in Zone 1/21, not listed for Class I or II, Division 2.
*** For use in Class I or II, Division 2 or Zone 1/21 depending on fitting used. Fitting manufactured by others.
Wall Boxes
Cable Range
NPT
.438 - .812
3/4”
.660 - 1.000
1”
NPT sizes are determined by the cable diameter and third party cord grip.
NPT
5.4 in 3+* NPT
81.9 in 3+ Cable Range
Poly 70° ++ Wall Box
.472 - .708
22-3AB58
Poly 70° ++ Poly 30°* Wall Box NPT Wall Box 1/2”
3/4”
– 22-3A023-34-T
5.4 in 3+* Poly 30°** Wall Box
75.0 in3+ Poly 70°*** Alum Wall Box
–
Accessory Spotlight Receptacle Lockout Pin
22-3A058-12
22-3A023-34-B
22-3A058-34
1”
–
–
1 1/4”
–
–
22-3A058-114
22-3A058-1
1 1/2”
–
–
22-3A058-112
+ Interior volume with receptacle installed. ++ Poly cord grip is located on the top of box.
* NPT thread on top. ** NPT thread on bottom. For bottom cord entry, rotate the box 180°. *** NPT is drilled on top of aluminum box as standard. For NPT on side only, add an “L” suffix. To switch from top to bottom or left to right the box can be rotated 180°.
Miscellaneous Accessories
* Set of Two (2)
NPT Guidelines
A 5/16” lockout pin can be ordered to securely lockout receptacles that include the ‘padlockable pawl’ option. Alternatively the user can utilize a lock with a 5/16” shank. Locks with smaller shanks will NOT securely lockout a receptacle pawl.
Order Example A typical order should include an inlet part number, a receptacle part number AND the matching handles, angles or other required accessories.
For Male Devices Only
Finger Drawplates
Protective Cap
Receptacle + Lockout Pin
61-3A346
22-3A426
LP-843
* Recommended for cord to cord assembly applications, for easier connector closure.
+
Requires Padlockable Pawl option (-843) on receptacle.
NEiW ngs
HP rated DXN30 AMPS
VAC (Max) @ 60 Hz
Phases
HP Rating
30 30 30 30
120V
1Ø 3Ø 3Ø 3Ø
1 hp 5 hp 10 hp 15 hp
480V 600V
HAZARDOUS LOCATION
Rat
DXN30 Horsepower Ratings
240V
Male Inlet with Handle (Plug) 22-38043 + 22-3A013-25P
• HP ratings are based on CSA certification
Female Receptacle with Wall Box 22-34043 + 22-3A023-34-T 184
DXN – 60A
DXN60
Hazardous Location Plugs & Receptacles Receptacle (female)
Ratings
Inlet (male)
• Voltage 600 VAC • Current Interruption Capability For current interrupting (AC) • Horsepower Ratings 120V 1Ø 2 hp 240V 3Ø 7.5 hp 480V 3Ø 20 hp 600V 3Ø 20 hp
Receptacles & Inlets must be mounted to a DXN handle, angle or wall box.
• Environmental Ratings IP66+IP67 • Wiring Capacity Min 10 AWG Max 4 AWG Aux Contacts - Max 10 AWG * Based on THHN wire sizes
Standard DXN60 lid opens to 120° Hazardous Location rating terminology and labeling is different for CE marked products – For international configurations (CE) visit meltric.com/international-catalog or contact customer service.
Part # Part # Voltage Polarity Voltage Polarity Poly Poly 1P+N+G 22-64165 1P+N+G 22-68165 120V 120V 125V 125V 1P+N+G 22-64075 1P+N+G 22-68075
• Listings+ CSA, IECEx, ATEX
2P+G 22-64162 2P+G 22-68162 208V 208V 3P+G 22-64163 3P+G 22-68163 208V 208V
* For CE rated devices, contact
customer service
3P+N+G 22-64167 3P+N+G 22-68167 208V 208V
• DXN60 Ratings Label
250V 250V 2P+G 22-64072 2P+G 22-68072
-40°C ≤Ta ≤+60°C Class I Zone1 Ex de IIC T5 DIP A21 T100°C Class I Zone1 AEx de IIC T5 tD 21 T100°C Class I div 2 Gr IIC (A,B,C,D) Class II div 2 Gr E,F,G cCSAus 208161-1144106X
The CSA ratings are applicable for
USA and Canada
Dust
-40°F < Ta < 104°F
T6
T80°C
-40°F < Ta < 140°F
T4
T100°C
Main Options 5/16” hole
250V 250V 2P+N+G 22-64076 2P+N+G 22-68076 277V 277V 1P+N+G 22-64045 1P+N+G 22-68045 480V 480V 2P+G 22-64042 2P+G 22-68042
3P+G 22-64043 3P+G 22-68043 480V 480V 480V 480V 3P+N+G 22-64047 3P+N+G 22-68047
• Temperature Table Ambient Temperature Gas
250V 250V 3P+G 22-64073 3P+G 22-68073
2P+G 22-64142 2P+G 22-68142 600V 600V 600V 600V 3P+G 22-64143 3P+G 22-68143
3P+N+G 22-64147 3P+N+G 22-68147 600V 600V
Devices rated for hazardous locations are not returnable. Receptacle Options
Padlock Pawl
Normally Closed Lid Configuration (unlatched)
185
Inlet Options
Part #
With 2 Auxiliary/Pilot Contacts* Recept # - 972
With 2 Auxiliary/Pilot Contacts* Inlet # - 972
Padlock Pawl
Recept # - 843
No Lockout Hole
Metal Pawl on Poly Receptacle
Recept # - 924
Closed Lid Configuration
Recept # - R
180˚ Lid Opening
Recept # - 180
* Not available with 600V devices, use -972-S74 for 550 VAC.
Inlet # - A155
Option Spotlight 2 Auxiliary Contacts
How to Order
Receptacle and Inlet (see above)
+ See pgs 205-214 for detailed information on these options
Part #
+
Accessories Angle, Handle, etc are interchangeable (see opposite page)
2 auxiliary/pilot contacts can be added for signal or control circuits. Avoid the need for separate connectors. To order add -972 to the inlet and receptacle part numbers.
DXN60
Installation Accessories Handles
For use with Class I/II Division 2 or Zone 1 /21 fittings
For Zone 1/ 21 applications
Cable Range Poly Handle w/Bushing+ .51 - .75
22-6A013-25P+
.67 - .98
22-6A013-32P+
.95 - 1.26
22-6A013-40P+
Angles
Nylon 30° Angle
NPT Poly Handle w/NPT***
1”
DXN accessories are not returnable.
22-6A027
22-6A013-1***
NPT Guidelines Cable Range
NPT
*** For use in Class I or II, Division 2 or Zone 1/ 21 depending on fitting used. Fitting manufactured by others.
.660 - 1.000
1”
Wall Boxes
NPT sizes are determined by the cable diameter and third party cord grip.
+ ATEX rated for use in Zone 1/21, not listed for Class I or II, Division 2.
NPT 11.1 in3+ NPT
183.3 in3+ Cable Range
Poly 70° ++ Wall Box
NPT
.629 - .984
22-6AB58
11.1 in3+
170.0 in3+
Poly 30°* Wall Box
Poly 30°** Wall Box
Poly 70°*** Alum Wall Box
1/2”
–
–
22-6A058-12
3/4”
–
–
22-6A058-34
1”
22-6A023-1-T
22-6A023-1-B
Finger Drawplates
22-6A058-1
1 1/4”
–
–
22-6A058-114
1 1/2”
–
–
22-6A058-112
+ Interior volume with receptacle installed. ++ Poly cord grip is located on the top of box.
* NPT thread on top. ** NPT thread on bottom. For bottom cord entry, rotate the box 180°. *** NPT is drilled on top of aluminum box as standard. For NPT on side only, add an “L” suffix. To switch from top to bottom or left to right the box can be rotated 180°.
Miscellaneous Accessories
* Set of Two (2)
Accessory Spotlight
Finger drawplates are recommended for easier connector closure on cord to cord assemblies.
Order Example A typical order should include an inlet part number, a receptacle part number AND the matching handles, angles or other required accessories.
For Male Devices Only
Finger Drawplates
Protective Cap
Receptacle + Lockout Pin
61-6A346
22-6A426
LP-843
* Recommended for cord to cord assembly applications, for easier connector closure.
+
Requires Padlockable Pawl option (-843) on receptacle.
NEiW ngs
HP rated DXN60 AMPS
VAC (Max) @ 60 Hz
Phases
HP Rating
60 60 60 60
120V
1Ø 3Ø 3Ø 3Ø
2 hp 7.5 hp 20 hp 20 hp
480V 600V
HAZARDOUS LOCATION
Rat
DXN60 Horsepower Ratings
240V
Male Inlet with Handle (Plug) 22-68043 + 22-6A013-32P
• HP ratings are based on CSA certification
Female Receptacle with Wall Box 22-64043 + 22-6A023-1-T 186