Belimo. Quality oriented safety in buildings We set standards. www.belimo.com
• Compact for space constrained locations • Three torque ranges: 30 in-lb, 70 in-lb, and 133 in-lb • Lowest current draws for the torque
&
• Auxiliary switch available • 24 VDC available • ISO 9001 quality control
D A M P E R A C T U AT O R S
®
Belimo is the worldwide leader in fire and smoke actuation.
Sonoma State University
Shell Point
FIESP Building
Pier 1 Imports
The Empire State Building
Canary Wharf
Sonoma, California
Fort Meyers, Florida
São Paulo, Brazil
Fort Worth, Texas
New York, New York
London, England
The Louvre
PeopleSoft
BOSE Corporation
Citibank
Mandalay Bay
Reichstag
Paris, France
Pleasanton, California
Framingham, Massachusetts
New York, New York
Las Vegas, Nevada
Berlin, Germany
Belimo is the largest Fire & Smoke Actuator manufacturer in the world.
2
State-of-the-art technology
Increased requirements
Belimo first produced actuators for
Legal fire protection regulations nor-
the European fire and smoke damper
mally only prescribe minimum re-
market in 1978. Belimo has consis-
quirements. Catastrophes with terri-
tently offered new technology since
ble consequences for people, tangi-
entering the market. Since 1978, Be-
ble assets, and high insurance costs,
limo’s market share has grown as
have caused the market to expect
actuator variations were released
more today than legal minimum from
to meet various worldwide require-
modern fire protection equipment. As
ments. The FSLF, FSNF, and FSAF
a result technical fire protection sys-
cover the needs of the United States
tems that take into account the in-
and regions of the world requiring
creased need for safety, have estab-
UL555 and UL555S listing.
lished themselves in practice.
Actuated dampers provide extra protection against the dangerous amounts of low-temperature toxic smoke that is produced before a fire actually breaks out.
Open damper
Closed damper
Open damper
Pressurized Zone
Closed damper
Smoke Zone
Open damper
Pressurized Zone
Closed damper
Re-openable dampers can assist in smoke control by allowing smoke to be exhausted from the fire zone and for fresh air to pressurize adjacent zones.
Active safety with motorized fire and smoke dampers • Warehouses employ smoke vents
Fire and smoke dampers are an inte-
and property in buildings is one of
to release smoke to the outside.
gral part of distribution systems and
the toughest demands that planners,
NFPA 204M allows fans in the roof
are critical links in the life safety sys-
builders, owners and operators are
with louvers and dampers in the
tems associated with most buildings.
side walls to control the smoke.
They offer extra protection against
Ensuring the safety of human life
called upon to face. Smoke related injuries and deaths outnumber fire re-
• Stairwell pressurization systems
the dangerous amounts of low tem-
lated injuries and deaths four to one.
combine fans and dampers to pre-
perature smoke often produced be-
This is a rising concern for the safety
vent smoke from entering the stair-
fore a fire actually breaks out. Re-
well from a burning floor.
stricting fires to the area of origin not
of people and fire fighters who need
• Building HVAC ducting systems
only helps stop fire spread but has
use motorized fire and smoke
been proven to allow sprinklers to
dampers to seal off individual
operate efficiently, and helps to en-
Tactical methods for smoke
zones. Dampers which are actu-
sure safety of human life.
control are: fans, smoke vents,
ated electrically can be controlled
and closed doors in combination with
from a central point and be inte-
dampers. Strategy varies
grated into safety control systems
with each situation.
allowing a relatively smoke free
to travel through building emergency exit routes as quickly as possible.
exit for occupants and entrance of fire fighters.
3
Belimo actuators: Optimized functionality for maximum safety.
M
Steel spring assembly • Heat resistant for reliability • Safety positions • Pretensioned for: – easier installation – higher contact pressure – assured damper sealing
5¡
Steel-toothed, cold-weld clamp The low thermal expansion coefficient steel clamp is the safest way to hold damper shafts without slipping.
TABLEAU 1 2 3
Auxiliary switches available in various configurations Actuator auxiliary switches signal damper position for testing in smoke control systems and where indicator lights are required.
Sturdy, galvanized steel housing
M Manual override available on FSAF 5¡ (Not available on FSLF or FSNF)
TABLEAU 1 2 3
1/2” threaded conduit connector.
Testing
designed for reliable performance in
Design
• Life cycle tests with rated load,
extreme conditions. There is no
The smoke and combination fire and
followed by 250/350°F cycle test
need to periodically cycle the
smoke damper actuator market has
simulating UL555S test conditions.
actuator.*
experienced serious problems in the
Fretting, corrosion and peeling of
past. The damper actuator has too
metal surfaces, has caused some
often been treated like a commodity
actuator gears to stick together.
item with low first cost being the #1
The damper can then stick open.
selection criteria.
This cannot occur with Belimo
As a result, noise, early failure, and
designed actuators.
operational problems have occurred.
• Alternating load variation to stress gears. • Ambient temperature testing from 30°F to 122°F. • All tests performed over an input voltage ranging from 108VAC to 132VAC. • A variety of functional tests to insure fail safe operation. • Extended life cycle tests at high torque loading. • Extended time stall tests per AMCA 520.
4
All steel V-bolt clamp Belimo clamps are 100% steel. The same saw-toothed cold weld clamp and V-bolt design is used on the fire and smoke actuators as is used in control applications. The V-bolt design will not crush hollow shafts.
Gearing
Belimo has sold over 24 million
Belimo is known for its precise
actuators with the 100% steel clamp.
tolerances and high quality gear
Its high quality has gained customer
boxes. Belimo’s FS gear boxes are
satisfaction.
In response to many of the difficulties, the UL555 and UL555S standards have been modified to require more stringent construction and testing. Belimo has designed the FS Series to ensure top quality actuation for smoke and combination dampers.
*Belimo does recommend periodic damper cycling per local code life safety testing requirements.
M
5¡
The Belimo product range: FSAF24-BAL-S
FSNF120-S US
•
•
•
•
•
•
•
•
•
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
0.23 A 10 VA
•
•
11 VA .1 A Auxiliary Switches
• •
•
Mechanical Accessories
• •
•
• •
•
• •
•
• •
•
•
•
•
•
•
•
27 VA
•
0.15A
•
•
•
•
•
5 VA
•
•
•
Consumption
•
• •
24 VAC/DC 120 VAC
FSAF24-BAL US
•
FSNF120 US
FSNF24-S US
•
FSAF24-SR-S US
•
FSAF24-SR US
•
•
FSAF120-S US
•
•
•
FSAF120 US
Power Supply* 24 VAC
•
•
•
FSAF24-S US
30 in-lb [3.5 Nm] minimum
•
•
FSAF24 US
70 in-lb [7.9 Nm] minimum
FSNF24 US
FSLF120-S
133 in-lb [15 Nm] constant
FSLF120 US
Torque
FSLF24-S
FSNF Series FSAF Series
FSLF24 US
FSLF Series
Model Number
Product Range /Technical Data
*230 VAC versions are available. -S models available with a variety of switch configurations. See data sheets available online.
Speed and temperature ratings
Engineered design criteria
Long service life
FSAF
250°F,