GRUNDFOS DATA BOOKLET
Series 100 Series 100 circulator pumps 50/60 Hz
Contents
General data Performance range Product range, 1 x 230 V, 50 Hz Type keys GRUNDFOS ALPHA2 GRUNDFOS ALPHA+ UP, UPS GRUNDFOS COMFORT Applications Heating systems Domestic hot-water systems Cooling and air-conditioning systems Construction Material specification Installation Motor Pumped liquids Ambient and liquid temperatures Maximum system pressure Inlet pressure Energy labelling Curve conditions
3 5 6 6 6 6 6 7 7 7 7 8 8 8 9 9 10 10 10 10 10
Technical data Circulator pumps for heating systems Air separator pump Circulator pumps for domestic hot water GRUNDFOS COMFORT Special versions Product range, special versions
11 22 25 27 32 34
Accessories Pipe connections Grundfos controls Union and valve kits Insulation kits Service kit for ALPHA2 and ALPHA+ Timer and thermostat for COMFORT Fittings for COMFORT
40 41 43 43 43 43 44
Further product documentation WebCAPS WinCAPS
2
45 46
General data
Series 100
Performance range
50
GRUNDFOS ALPHA2
6
5
40
4
30
3
20
2
AL PH A2
ALP HA2
10
1
0
0 0.0
p [kPa] 50
0.4
0.8
1.2
1.6
XX-
2.0
40
AL PH A2 XX -50
2.4
2.8
H [m]
XX -60
Q [m³/h]
TM03 9502 4107
60
H [m]
GRUNDFOS ALPHA+
5
40
4
30
3
20
2
AL 10
1
0
0
ALP HA +X X -4
0.0
0.0
0.5
1.0
0.2
1.5
0.4
2.0
0
2.5
0.6
3.0
0.8
PH A+
XX -60
3.5
Q [m³/h] 1.0
Q [l/s]
TM01 9186 2505
p [kPa]
3
General data
60
10.0 8.0 6.0
40
4.0
UPS
2
0.2
UP
5-30
UP 25-20 UP
0.6
0.3
0.4
0.6
H [m]
0.6
4
0.4
UP 2
2014 B X
4.0
0.6
6.0
0.8 1.0
8.0Q [m³/h] 2.0
Q [l/s]
UP 25 -80 B
UP
30 N
S4 0-
50 F
B
0-15 N
UP 2 2
)
)
6
0F
0
UP 20 -
1 5 -1 4B
(F
0
-60 B UP 20-4 5N UPS 25-40 B
UP
0
0
UPS 2 5
UP
-8
(FB
0.8
-5
32
0B 2-8
1.0
8
-3
0.4
2.0
40
0
2.0
4.0
10
0
S
S
S3 UP
20
2-4
2-5
COMFORT, UP-N, UP(S)-B
6.0 40
2-2
32
0.8 1.0 0.2
p [kPa]
S3
S
S3
S3
2-6
UP
UP
0
F
0.4
UP
S3
25-8
0
4
UP
-8
1.0 0.8
UPS
40
UPS
UPS 25
S
UPS 2
5-1
20
UPS 25 -60 UPS 2 5-50 UPS 25 -40
2.0
10 8 6
25-1
S2
UP
20
UP
0-07 N
0.2
0.1 0
0.2
0.4
0.6
0.8
1
2
4
6
8
10
Q [m³/h] 0.2
4
TM00 9602 3701
100 80
H [m]
0.4
0.6
0.8 1.0
2.0
Q [l/s]
TM00 9603 0503
p [kPa]
Series 100
General data
Series 100
Product range, 1 x 230 V, 50 Hz Cast iron
Cast iron
Cast iron
Stainless steel/bronze
Stainless steel/bronze
Bronze
Brass
Liquid temperature
+2 °C to +95 °C
+2 °C to +110 °C
–25 °C to +110 °C
–25 °C to +95 °C
+2 °C to +110 °C
–25 °C to +110 °C
–25 °C to +95 °C
+2 °C to +95 °C
Control box position
TM03 8497 1707
Cast iron
TM03 8497 1707
Pump material
Pump type
z z
ALPHA2 32-60
z
Terminal box position
z TM02 7023 2303
z
ALPHA2 25-60 TM02 7023 2303
ALPHA2 15-60
ALPHA+ 15-40
z
ALPHA+ 25-40
z
ALPHA+ 32-40
z
ALPHA+ 15-60
z
ALPHA+ 25-60
z
ALPHA+ 32-60
z
UPS 25-20
z
UPS 32-20
z
UPS 25-30
z
UPS 32-30
z
UPS 25-40
z
UPS 32-40
z
UPS 25-50
z
UPS 32-50
z
UPS 25-60
z
UPS 32-60
z
TM02 7022 2303
ALPHA2 25-50
z
TM02 7024 2303
z
TM02 7024 2303
ALPHA2 32-40
TM02 7023 2303
z
TM02 7024 2303
z
ALPHA2 25-40
TM02 7024 2303
ALPHA2 15-40
z
z
z z z z
UPS 25-80
z
UPS 32-80 UPS 25-120
z
UPS 25-125
z
UPS 40-50 F
z
UPS 32-80 F
z
UPS 40-80 F
z z
UP 15-14
z
UP 20-14 UP 20-07 N
z
UP 20-15 N
z
UP 20-30 N
z z
UP 20-45 N UPS 25-40 B
z
UPS 25-60 B
z
z
UP 25-80 B
z
UPS 32-80 B
z
UPS 32-50 FB
z
UPS 40-50 FB
z
On request: Pump housing with air separator, type A. Special range of twin-head pumps and 60 Hz pumps, page 34.
5
General data
Series 100
Type keys GRUNDFOS ALPHA2 Example
GRUNDFOS COMFORT ALPHA2
25
-40
180
Example
Type range
Type range
Nominal diameter (DN) of suction and discharge ports [mm]
Type range: 15 = Rp 1/2, length 80 mm 20 = G 1 1/4, length 110 mm
Maximum head [dm]
Maximum head [dm]
: cast-iron pump housing N: stainless-steel pump housing A: pump housing with air separator
Brass pump housing Integrated isolating and non-return valves
Port-to-port length [mm]
24-hour timer
GRUNDFOS ALPHA+ Thermostat Example
ALPHA+
25
-40
(A)
(B)
180
Type range Nominal diameter (DN) of suction and discharge ports [mm] Maximum head [dm]
Pump housing with air separator
Bronze pump housing
Port-to-port length [mm]
UP, UPS Example
UP
S
D
40
Type range
S = electric
Twin-head pump
Nominal diameter (DN) of suction and discharge ports [mm]
Maximum head [dm] Pipe connection: = pipe thread (no letter = pipe thread) F = flange Pump housing: = cast iron (no letter = cast iron) N = stainless steel B = bronze A = pump housing with air separator, upward water flow K = cold-water version KU = cold-water version (filled terminal box)
6
UP 20 -14
-40
F
B
X
U
T
General data
Series 100
Applications The Grundfos circulator pumps, Series 100, are specifically designed for heating systems. The pumps are also suitable for circulation of domestic hot water and for circulation of liquid in cooling and airconditioning systems.
TM03 8990 4507
Heating systems For central and district heating systems, use pump type ALPHA2, ALPHA+ or UPS. The GRUNDFOS ALPHA2 and ALPHA+ automatically control the differential pressure by adjustment of pump performance to the actual heating demand, without the use of external components.
Fig. 1 One-pipe heating system
UPS can be operated at three different speeds. The pumps are used primarily for one- and two-pipe heating systems, but are also suitable, e.g. for mixing loops in large systems.
TM03 8989 4507
For underfloor heating systems, it is advisable to use the pump type ALPHA2 N, ALPHA+ B or UP(S) B, as the pumped liquid may often become aerated, causing an ordinary cast-iron pump housing to corrode.
Domestic hot-water systems For circulation in domestic hot-water systems, use type ALPHA2 N, COMFORT, UP N with stainless-steel pump housing or UP(S) B with brass/bronze pump housing.
Fig. 2 Two-pipe heating system
The UP N and UP(S) B can be connected to an on/off time switch to save energy. The on/off time switch can switch the pump on/off to limit pump operation to periods when hot water is usually required. TM03 9890 4507
GRUNDFOS COMFORT is available with integrated timer and thermostat. It is recommended to keep the operating temperature lower than 65 °C to avoid lime precipitation.
Cooling and air-conditioning systems
Fig. 3 Underfloor heating system
For cooling and air-conditioning systems, use standard pumps, type UPS, or special versions, type UPS K, depending on type and size. See Product range on page 5.
TM03 9887 4507
Temperature range: –25 °C to +95 °C –25 °C to +110 °C. These pumps are thus suitable for circulation of both cold and hot water.
Fig. 4 Domestic hot-water system
7
General data
Series 100
Construction The ALPHA2, ALPHA+, UP and UPS pumps are of the canned-rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. The pumps are characterised by
• carbon thrust bearing
2
• stainless-steel rotor can and bearing plate
5
• impeller in corrosion-resistant material
1 4
• pump housing of cast iron, bronze or stainless steel.
Material specification
TM00 9672 5196
3
• ceramic shaft and radial bearing
6
Fig. 6 UPS, N-version Pos. Component
Material Cast iron EN-GJL-150/200
1
Pump housing
2
Impeller
Composite, PP or PES
3
Shaft
Ceramics
4
Bearing
Ceramics/carbon
5
Bearing plate
Stainless steel
6
Thrust bearing Stainless steel/ retainer EPDM rubber Gaskets
Bronze Stainless steel
DIN W.-Nr. EN-JL 1020/ 1030 2.1176.01 1.4308
1.4301 1.4301
EPDM rubber
Fig. 5 ALPHA2 Pos. 1 9 11
12
8
Component
Material
Controller complete
Composite, PC
Rotor can
Stainless steel
Radial bearing
Ceramics
Shaft
Ceramics
Rotor cladding
Stainless steel
Thrust bearing
Carbon
Thrust bearing retainer
EPDM rubber
13
Bearing plate
Stainless steel
16
Impeller
Composite, PP or PES
18
Pump housing
Cast iron Stainless steel
Gaskets
EPDM rubber
EN/DIN W.-Nr.
AISI/ ASTM
1.4301
304
1.4301
304
The pump must always be installed with horizontal motor shaft. At start-up the rotor can is to be vented by removing the plug in the top of the motor. Within a short time, the rotor forces the remaining air out into the system via the shaft.
TM00 0361 5196
TM03 9728 4307
Installation
Fig. 7 Pumps with horizontal motor shaft
1.4301
304
EN-JL 1020 EN 1.4308
A48-25 B
General data Motor
Series 100
GRUNDFOS ALPHA2 The motor is a 4-pole, synchronous permanent-magnet motor.
UP and UPS pumps The motor is a 2- or 4-pole, asynchronous squirrel-cage motor in conformity with the EMC directive. The motors comply with EN 61000-6-2 and EN 61000-6-3.
The pump controller is incorporated in the control box which is fitted to the stator housing with two screws and connected to the stator via a terminal plug.
The terminal box and the motor-pump unit have been wet-tested to EN 60335-1: 2002 and EN 60335-2-51: 2003.
Incorporating the controller, the control box has a display and two selector buttons. The display is lit when the electricity supply is switched on and shows the actual power consumption.
Single-phase pumps are available in versions with one, two or three speeds.
The buttons are used for • selection of pump setting • activation or deactivation of Automatic Night SetBack. The controller complies with EN 61000-6-2 and EN 61000-6-3. The motor of GRUNDFOS ALPHA2 is protected by the electronics in the control box and requires no external motor protection. GRUNDFOS ALPHA+ The motor is a 2-pole, asynchronous squirrel-cage motor with radio noise filter to VDE 0875. The terminal box and motor-pump unit have been tested in accordance with VDE 0700. The terminal box is fitted to the stator housing with screws and connected to the stator via a terminal plug. Incorporating the controller, the terminal box has a selector switch and an indicator light for power on indication.
Three-phase pumps are available in versions with one or two speeds. The terminal box is easily accessible and has functional cable connecting terminals. The cable entry is tight and has a built-in cable relief. The cable entry of single-phase motors can be pushed out of its guide to facilitate the correct fitting of the cable. Insulation class: F/H. Cable connection: Pg 11 for 5.6 to 10 mm cable. The motor incorporates thermal overload or impedance protection. Therefore, no external motor protection is required.
Pumped liquids Depending on type, Grundfos circulator pumps are suitable for the following liquids: • clean, thin, non-aggressive and non-explosive liquids without solid particles or fibres • cooling liquids, not containing mineral oil • domestic hot water
The controller complies with EN 61800-3.
• softened water.
The motor of GRUNDFOS ALPHA+ is impedanceprotected and therefore requires no external motor protection.
The kinematic viscosity of water is υ = 1 mm2/s (1 cSt) at 20 °C. If the circulator pump is used for a liquid with a higher viscosity, the hydraulic performance of the pump will be reduced. Example: 50 % glycol at 20 °C means a viscosity of approx. 10 mm2/s (10 cSt) and a reduction of pump performance by approx. 15 %. When selecting a pump, the viscosity of the pumped liquid must be taken into consideration.
9
General data
Series 100
Ambient and liquid temperatures
Curve conditions
Liquid temperatures, see table on page 5.
The guidelines below apply to the performance curves on the following pages:
The ambient temperature for standard pumps with a permissible liquid temperature from +2 °C to +110 °C should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing.
Maximum system pressure Pump with unions (PN 10):
1.0 MPa (10 bar).
Flanged pump (PN 6/10):
0.6/1.0 MPa (6/10 bar).
Pump with Grundfos flanges: 1.0 MPa (10 bar).
To avoid cavitation noise and damage to the pump bearings, the following minimum pressures are required at the pump suction port.
Inlet pressure
85 °C
90 °C
110 °C
0.5 m head
2.8 m head
11.0 m head
0.049 bar
0.27 bar
1.08 bar
Energy labelling Grundfos circulator pumps, except GRUNDFOS COMFORT, UP N and twin-head pumps, are provided with the energy label. The energy label indicates the energy-saving level of the pump. The energy classification system has seven levels, i.e. from A to G. Level A is the best.
TM03 0868 0705
The energy label can be used to compare pumps of the same type and size.
Fig. 8 Energy label, A-labelled GRUNDFOS ALPHA2
10
• Test liquid: airless water. • The GRUNDFOS ALPHA2 and ALPHA+ curves apply to a density of ρ = 983.2 kg/m3 and a liquid temperature of 60 °C. The measurements for UP and UPS have been made at a water temperature of 80 °C for pumps for Great Britain (1 x 230/240 V) and 20 °C for other pumps. • All curves show average values and should not be used as guarantee curves. If a specific minimum performance is required, individual measurements must be made.
Inlet pressure
Liquid temperature
• The bold parts of the curves show the recommended performance range.
• The GRUNDFOS ALPHA2 and ALPHA+ curves apply to a kinematic viscosity of υ = 0.474 mm2/s (0.474 cSt). The UP and UPS curves apply to a kinematic viscosity of υ = 1 mm2/s (1 cSt). • The conversion between head H [m] and pressure p [kPa] has been made for water with a density of ρ = 1000 kg/m3. For liquids with other densities, e.g. hot water, the discharge pressure is proportional to the density.
Technical data
Circulator pumps for heating systems
ALPHA2 15-40, 25-40, 32-40
1 x 230 V, 50 Hz
4
30
3
20
2
10
1
0
0 0.0 0.0
0.4 0.1
0.8 0.2
1.2 0.3
1.6 0.4
2.0 0.5
0.6
Q [m³/h] Q [l/s ]
TM03 9436 4007
40
TM03 9215 3607
p H [kP a] [m]
Speed
P1 [W]
I1/1 [A]
Min.
5
0.05
System pressure:
Max. 10 bar
Max.
22
0.19
Liquid temperature:
+2 °C to +110 °C (TF 110)
Energy class:
A
Also available with:
Stainless-steel pump housing, type N (only ALPHA2 25-40 N 180)
Connections:
The pump incorporates overload protection.
Pump type
See "Union and valve kits" on page 40
Dimensions [mm]
Weights [kg] G
Net
Gross
Ship. vol. [m3]
79
1
1.9
2.1
0.00383
79
1 1/2
1.9
2.1
0.00383
127
81
1 1/2
2.1
2.3
0.00383
127
81
2
2.1
2.3
0.00383
L1
B1
B2
B3
B4
H1
H2
H3
ALPHA2 15-40
130
77
78
46
49
27
129
ALPHA2 25-40
130
77
78
46
49
27
129
ALPHA2 25-40 (N)
180
78
77
47
48
26
ALPHA2 32-40
180
78
77
47
48
26
11
Technical data
Circulator pumps for heating systems
ALPHA2 25-50
1 x 230 V, 50 Hz
5
40
4
30
3
20
2
10
1
0
0 0.0
0.4
0.0
0.1
0.8 0.2
1.2 0.3
1.6 0.4
2.0
0.5
2.4
0.6
0.7
Q [m³/h] Q [l/s ]
TM03 9697 4307
50
TM03 9215 3607
p H [kP a] [m]
Speed
P1 [W]
I1/1 [A]
Min.
5
0.05
System pressure:
Max. 10 bar
Max.
32
0.27
Liquid temperature:
+2 °C to +110 °C (TF 110)
Energy class:
A
Connections:
The pump incorporates overload protection.
Dimensions [mm]
Weights [kg]
L1
B1
B2
B3
B4
H1
H2
H3
G
Net
Gross
Ship. vol. [m3]
ALPHA2 25-50
130
77
78
46
49
27
129
79
1 1/2
1.9
2.1
0.00383
ALPHA2 25-50
180
78
77
47
48
26
127
81
1 1/2
2.1
2.3
0.00383
Pump type
12
See "Union and valve kits" on page 40
Technical data
Circulator pumps for heating systems
ALPHA2 15-60, 25-60, 32-60
1 x 230 V, 50 Hz
5
40
4
30
3
20
2
10
1
0
0 0.0
0.4
0.0
0.1
0.8 0.2
1.2 0.3
1.6 0.4
2.0
0.5
0.6
2.4 0.7
Q [m³/h] Q [l/s ]
TM03 9437 4007
50
TM03 9215 3607
p H [kP a] [m] 60 6
Speed
P1 [W]
I1/1 [A]
Min.
5
0.05
System pressure:
Max. 10 bar
Max.
45
0.38
Liquid temperature:
+2 °C to +110 °C (TF 110)
Energy class:
A
Also available with:
Stainless-steel pump housing, type N (only ALPHA2 25-60 N 180)
Connections:
The pump incorporates overload protection.
Pump type
See "Union and valve kits" on page 40
Dimensions [mm]
Weights [kg] G
Net
Gross
Ship. vol. [m3]
79
1
1.9
2.1
0.00383
79
1 1/2
1.9
2.1
0.00383
127
81
1 1/2
2.1
2.3
0.00383
127
81
2
2.1
2.3
0.00383
L1
H1
H2
H3
B1
B2
B3
E
ALPHA2 15-60
130
77
78
46
49
27
129
ALPHA2 25-60
130
77
78
46
49
27
129
ALPHA2 25-60 (N)
180
78
77
47
48
26
ALPHA2 32-60
180
78
77
47
48
26
13
Technical data
Circulator pumps for heating systems
ALPHA+ 15-40, 25-40, 32-40
1 x 230 V, 50 Hz
H [m] B3
4
H3
G
3
L
2
0 0.0
0.4
0
0.8 10
1.2
1.6
20
2.0 30
2.4
Q [m³/h]
40
Q [l/min]
B1
B2
H2
H1
Speed
P1 [W]
I1/1 [A]
Min.
20
0.09
Connections: System pressure:
See "Union and valve kits" on page 40 Max. 10 bar
Max.
45
0.22
Liquid temperature:
+2 °C to +110 °C (TF 110)
I
25
0.10
Energy class:
B
II
35
0.16
Also available with:
III
45
0.22
Bronze housing, type B (only ALPHA+ 25-40 B 180)
The motor incorporates thermal overload protection.
Pump type
Dimensions [mm] G
Net
Gross
Ship. vol. [m3]
H1
H2
H3
B1
B2
B3
ALPHA+ 15-40
130
28
103
57
92
48
77
1
2.4
2.6
0.00432
ALPHA+ 25-40
130
32
103
57
92
48
77
1 1/2
2.4
2.6
0.00432
ALPHA+ 25-40
180
32
103
57
92
48
77
1 1/2
2.6
3.0
0.00432
ALPHA+ 32-40
180
39
103
57
92
48
77
2
2.7
3.1
0.00432
Weights of bronze versions are approx. 10 % higher.
14
Weights [kg]
L
TM03 1632 2505
TM03 1344 1705
1
Technical data
Circulator pumps for heating systems
ALPHA+ 15-60, 25-60, 32-60
1 x 230 V, 50 Hz
H [m] 6
B3
H3
G
5 4
2 TM03 1345 1705
1 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h] 0
10
20
30
40
50
Q [l/min]
B1
B2
H2
H1
Speed
P1 [W]
I1/1 [A]
Connections:
See "Union and valve kits" on page 40
Min.
35
0.14
System pressure:
Max. 10 bar
Max.
80
0.34
Liquid temperature:
+2 °C to +110 °C (TF 110)
I
40
0.17
Energy class:
B
II
55
0.23
Also available with:
III
80
0.34
Bronze housing, type B (only ALPHA+ 25-60 B 180)
TM03 1632 2505
L
3
The motor incorporates thermal overload protection. Dimensions [mm]
Pump type
Weights [kg] G
Net
Ship. vol. [m3]
L
H1
H2
H3
B1
B2
B3
Gross
ALPHA+ 15-60
130
28
103
57
92
48
77
1
2.4
2.6
0.00432
ALPHA+ 25-60
130
32
103
57
92
48
77
1 1/2
2.4
2.6
0.00432
ALPHA+ 25-60
180
32
103
57
92
48
77
1 1/2
2.6
3.0
0.00432
ALPHA+ 32-60
180
39
103
57
92
48
77
2
2.7
3.1
0.00432
Weights of bronze versions are approx. 10 % higher.
UPS 25-20 / UPS 32-20 p [kPa]
H [m]
20
2.0
180
1 x 230 V, 50 Hz
1.5
2
10
1.0
1
5
0.5
0
0.0 0.0
0.0
0.4
0.1
0.8
0.2
1.2
0.3
1.6
0.4
2.0 Q [m³/h]
0.5
Q [l/s]
TM00 9386 2105
15
TM00 9756 2405
3
Speed
P1 [W]
I1/1 [A]
3
65
0.26
Connections: System pressure:
Max. 10 bar
2
40
0.18
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.11
Energy class:
F
Dimensions [mm]
3/4" or 1" unions and valves
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
UPS 25-20
180
32
102
75
51
1 1/2
2.6
2.8
0.004
UPS 32-20
180
39
102
75
51
2
2.6
2.8
0.004
Pump type
15
Technical data
Circulator pumps for heating systems
UPS 25-30 / UPS 32-30 p [kPa]
H [m]
25
2.5
180
1 x 230 V, 50 Hz
3
15
1.5
10
1.0
5
0.5
0
0.0
1
0.0
0.5
0.0
0.1
1.0
0.2
0.3
1.5
0.4
2.0
0.5
2.5
0.6
0.7
Q [m³/h]
0.8
Q [l/s]
TM00 9386 2105
2.0
2
TM00 9748 0397
20
Speed
P1 [W]
I1/1 [A]
Connections:
3/4" or 1" unions and valves
3
55
0.24
System pressure:
Max. 10 bar
2
40
0.16
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.10
Energy class:
D
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
UPS 25-30
180
32
102
75
51
1 1/2
2.6
2.8
0.004
UPS 32-30
180
39
102
75
51
2
2.6
2.8
0.004
Pump type
180
UPS 25-40 / UPS 32-40 p [kPa]
H [m]
40
4
1 x 230 V, 50 Hz
3 2
30
3
20
2
10
1
0
0
0.0
1.0
0.2
1.5
2.0
0.4
2.5
0.6
Q [m³/h]
0.8
Q [l/s]
Connections:
3/4", 1" or 11/4" unions and valves
Speed
P1 [W]
I1/1 [A]
3
45
0.20
System pressure:
Max. 10 bar
2
35
0.16
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.12
Energy class:
B
Cold-water version:
K for –25 °C to +95 °C (TF 95)
Pump type
16
0.5
TM00 9749 2405
0.0
TM00 9386 2105
1
Dimensions [mm] L
H1
H2
B1
Weights [kg] B2
G
Net
Gross
Ship. vol. [m3]
UPS 25-40
180
32
102
75
51
1 1/2
2.6
2.8
0.004
UPS 32-40
180
39
102
75
51
2
2.6
2.8
0.004
Technical data
Circulator pumps for heating systems
180
UPS 25-50 / UPS 32-50 p [kPa]
H [m]
40
4
30
3
20
2
10
1
0
0
1 x 230 V, 50 Hz
3 2
0.5
0.0
1.0
0.2
1.5
2.0
0.4
2.5
0.6
3.0
0.8
Q [m³/h]
Q [l/s]
TM00 9386 2105
0.0
TM00 9750 2105
1
Speed
P1 [W]
I1/1 [A]
Connections:
3/4", 1" or 1 1/4" unions and valves
3
50
0.23
System pressure:
Max. 10 bar
2
45
0.20
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
35
0.16
Energy class:
B
Cold-water version:
K for –25 °C to +95 °C (TF 95)
Dimensions [mm]
Pump type
L
H1
H2
B1
Weights [kg] B2
G
Net
Ship. vol. [m3]
Gross
UPS 25-50
180
32
102
75
51
1 1/2
2.6
2.8
0.004
UPS 32-50
180
39
102
75
51
2
2.6
2.8
0.004
180
UPS 25-60 / UPS 32-60 p [kPa]
H [m]
50
5
2
40
4
1
30
3
20
2
10
1
0
0
1 x 230 V, 50 Hz
0.0
0.5
1.0
0.2
1.5
2.0
0.4
0.6
2.5
3.0
0.8
Q [m³/h]
Q [l/s]
TM00 9386 2105
0.0
TM00 9751 2405
3
Speed
P1 [W]
I1/1 [A]
Connections:
3/4", 1" or 1 1/4" unions and valves
3
70
0.30
System pressure:
Max. 10 bar
2
60
0.27
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
50
0.22
Energy class:
C
Cold-water version:
K for –25 °C to +95 °C (TF 95)
Pump type
Dimensions [mm] L
H1
H2
B1
Weights [kg] B2
G
Net
Gross
Ship. vol. [m3]
UPS 25-60
180
32
102
75
51
1 1/2
2.6
2.8
0.004
UPS 32-60
180
39
102
75
51
2
2.6
2.8
0.004
17
Technical data
Circulator pumps for heating systems
180
UPS 25-80
70
7
60
6
50
5
40
4
30
3
20
2
10
1
0
0
8
3 2
1
0
1
0.0
2
3
0.5
4
5
1.0
6
1.5
7
8
Q [m³/h]
2.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
Connections:
3/4" or 1" unions and valves
3
190
0.83
System pressure:
Max. 10 bar
2
175
0.78
Liquid temperature:
–25 °C to +110 °C (TF 110)
1
130
0.60
Energy class:
D
Dimensions [mm]
UPS 25-80
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
130
82
52
1 1/2
4.2
4.5
0.008
Pump type
180
UPS 32-80 p [kPa] 80
TM00 8945 2105
H [m]
TM00 9754 2405
p [kPa] 80
1 x 230 V, 50 Hz
1 x 230 V, 50 Hz
H [m] 8
3 2
7 60
6 5
40
1
4 3
20
0 0
0.0
2
0.5
3
4
1.0
5
6
1.5
7
2.0
8
9
2.5
10
Q [m³/h]
3.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
Connections:
3/4" or 1" unions and 1 1/4" valves
3
240
1.05
System pressure:
Max. 10 bar
2
205
0.91
Liquid temperature:
–25 °C to +110 °C (TF 110)
1
135
0.62
Energy class:
D
Pump type UPS 32-80
18
1
TM00 9753 2405
1 0
TM00 8945 2105
2
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
39
130
82
60
2
4.8
5.1
0.0102
Technical data
Circulator pumps for heating systems
180
UPS 25-120 p [kPa]
H [m]
120
12
100
10
80
8
60
6
40
4
20
2
0
0
1 x 230 V, 50 Hz
3 2
0.5
0.0
1.0
0.2
1.5
0.4
2.0
2.5
0.6
3.0
0.8
3.5
1.0
Q [m³/h]
Q [l/s]
TM02 1329 2105
0.0
TM02 2205 3901
1
Speed
P1 [W]
I1/1 [A]
Connections:
3/4" unions and valves
3
235
1.02
System pressure:
Max. 10 bar
2
180
0.78
Liquid temperature:
–25 °C to +95 °C (TF 110)
1
120
0.53
Energy class:
F
Dimensions [mm]
UPS 25-120
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
130
82
69
1 1/2
4.4
4.6
0.006
180
UPS 25-125 p [kPa]
H [m]
120
12
100
10
80
8
60
6
40
4
20
2
0
0
Weights [kg]
L
Pump type
1 x 230 V, 50 Hz
3 2
0.0
Speed
0.5
1.0
0.2
1.5
0.4
2.0
2.5
0.6
3.0
0.8
3.5
1.0
P1 [W]
Q [m³/h]
Q [l/s]
TM02 2204 3901
0.0
TM02 1329 2105
1
I1/1 [A]
Connections:
3/4" unions and valves Max. 10 bar
3
270
1.18
System pressure:
2
210
0.93
Liquid temperature:
+2 °C to +95 °C (TF 95)
1
135
0.61
Energy class:
E
Pump type UPS 25-125
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
130
82
69
1 1/2
4.4
4.6
0.006
19
Technical data
Circulator pumps for heating systems
220
UPS 32-80 F p [kPa] 80
H [m] 8
3 2
7 60
1 x 230 V, 50 Hz
6 5
40
1
4 3 2
0 0
1
0.0
2
3
0.5
4
5
1.0
6
7
1.5
8
9
2.0
10
Q [m³/h]
2.5
3.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
240
1.05
2
205
0.91
1
135
0.62
5
40
4
30
3
20
2
10
1
0
0
System pressure:
Max. 6/10 bar
Liquid temperature:
+2 °C to +110 °C (TF 110)
Energy class:
D
Weights [kg]
H1
H2
B1
B2
Net
Gross
Ship. vol. [m3]
220
60
130
85
65
6.5
6.8
0.0112
UPS 40-50 F
50
1 1/4" screwed flanges or 32 mm flanges for welding
Dimensions [mm]
UPS 32-80 F
H [m]
Connections:
L
Pump type
p [kPa]
TM00 9393 2105
1 0
TM00 9753 2405
20
250
1 x 230 V, 50 Hz
3 2
0.0
2
0.5
3
4
5
1.0
6
1.5
7
8
9
2.0
Q [m³/h]
2.5
Q [l/s]
P1 [W]
I1/1 [A]
3
115
0.51
System pressure:
Max. 6/10 bar
2
110
0.48
Liquid temperature:
–25 °C to +110 °C (TF 110)
1
85
0.38
Energy class:
C
UPS 40-50 F
Connections:
1 1/2" screwed flanges or 40 mm flanges for welding
Speed
Pump type
20
1
TM00 9393 2105
0
TM00 9755 2405
1
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
Net
Gross
Ship. vol. [m3]
250
65
130
82
65
8.1
8.5
0.0122
Technical data
Circulator pumps for heating systems
250
UPS 40-80 F p [kPa] 80
H [m] 8
3 2
7 60
1 x 230 V, 50 Hz
6 5
40
1
4 3 2
0 0
0.0
1
2
0.5
3
4
1.0
5
6
1.5
7
2.0
8
9
10
2.5
Q [m³/h]
3.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
240
1.05
2
205
0.91
1
135
0.62
Pump type UPS 40-80 F
TM00 9389 2105
1 0
TM00 9753 2405
20
Connections:
1 1/2" screwed flanges or 40 mm flanges for welding
System pressure:
Max. 6/10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Energy class:
D
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
Net
Gross
Ship. vol. [m3]
250
65
130
82
65
8.1
8.5
0.0122
21
Technical data
Circulator pumps for heating systems
Air separator pump Grundfos Airlectric is a combined circulator pump and air separator. The air separator removes air from the centre of the system and thus offers optimum operating conditions for any automatic air vent – without extra installation cost.
TM00 8966 4296
The air-containing liquid is guided from the suction port to the nozzle of the air-separating chamber. In the nozzle, the liquid is caused to circulate considerably in the relatively large chamber, thus creating a low pressure in the top of the chamber. This low pressure combined with the now reduced low velocity of the liquid will cause a separation of air from the liquid. Due to its lower density, the air will escape through an automatic air vent fitted to the air-separating chamber. The air separator pump is available only for upward water flow. The pump housing has an Rp 3/8 thread for the air vent. The air vent is not supplied with the pump. Fig. 9 Air separator pump
22
Technical data
Circulator pumps for heating systems
ALPHA2 25-40 A
1 x 230 V, 50 Hz
4
30
3
20
2
10
1
0
0 0.0 0.0
0.4 0.1
0.8 0.2
1.2
1.6
0.3
0.4
2.0 0.5
Q [m³/h]
0.6
Q [l/s ]
TM03 9436 4007
40
TM03 9211 3607
p H [kP a] [m]
Speed
P1 [W]
I1/1 [A]
Min.
5
0.05
System pressure:
Max. 10 bar
Max.
22
0.19
Liquid temperature:
+2 °C to +110 °C (TF 110)
Energy class:
A
Connections:
The pump incorporates overload protection.
See "Union and valve kits" on page 40
Dimensions [mm]
Pump type ALPHA2 25-40 A
Weights [kg]
L1
B1
B2
B3
B4
H1
H2
H3
G
Net
Gross
Ship. vol. [m3]
180
64
91
34
65
50
137
71
1 1/2
3.1
3.3
0.0063
1 x 230 V, 50 Hz
ALPHA2 25-60 A
5
40
4
30
3
20
2
10
1
0
0 0.0
0.4
0.0
0.1
0.8 0.2
1.2 0.3
1.6 0.4
2.0
0.5
0.6
2.4 0.7
Q [m³/h] Q [l/s ]
TM03 9437 4007
50
TM03 9211 3607
p H [kP a] [m] 60 6
Speed
P1 [W]
I1/1 [A]
Min.
5
0.05
System pressure:
Max. 10 bar
Max.
45
0.38
Liquid temperature:
+2 °C to +110 °C (TF 110)
Energy class:
A
Connections:
The pump incorporates overload protection.
Pump type ALPHA2 25-60 A
See "Union and valve kits" on page 40
Dimensions [mm]
Weights [kg]
L1
H1
H2
H3
B1
B2
B3
E
G
Net
Gross
Ship. vol. [m3]
180
78
77
47
48
26
127
81
1 1/2
3.1
3.3
0.0063
23
Technical data
Circulator pumps for heating systems
180
ALPHA+ 25-40 A
1 x 230 V, 50 Hz
H [m] 4
Rp 3/8
B3
G
H3
3
L
2
0.0
0.4
0
0.8 10
1.2
1.6
20
2.0 30
2.4
Q [m³/h]
40
Q [l/min]
B1
B2
H2
H1
Connections:
TM03 1631 2505
0
TM03 1344 1705
1
See "Union and valve kits" on page 40
Speed
P1 [W]
I1/1 [A]
Min.
20
0.09
System pressure:
Max. 10 bar +2 °C to +110 °C (TF 110) B
Max.
45
0.22
Liquid temperature:
I
25
0.10
Energy class:
II
35
0.16
III
45
0.22
The motor incorporates thermal overload protection. Dimensions [mm]
Pump type ALPHA+ 25-40 A
Weights [kg]
L
H1
H2
H3
B1
B2
B3
G
Net
Gross
Ship. vol. [m3]
180
49
113
81
92
51
78
1 1/2
3.6
4.0
0.00542
ALPHA+ 25-60 A
180
1 x 230 V, 50 Hz
H [m] 6
Rp 3/8
B3
G
5
H3
4
2 TM03 1345 1705
1 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h] 0
10
20
30
40
50
Q [l/min]
B1
B2
H1
TM03 1631 2505
L
3
H2
Speed
P1 [W]
I1/1 [A]
Connections:
See "Union and valve kits" on page 40
Min.
35
0.14
System pressure:
Max. 10 bar
Max.
80
0.34
Liquid temperature:
+2 °C to +110 °C (TF 110)
I
40
0.17
Energy class:
B
II
55
0.23
III
80
0.34
The motor incorporates thermal overload protection.
Pump type ALPHA+ 25-60 A
24
Dimensions [mm]
Weights [kg]
L
H1
H2
H3
B1
B2
B3
G
Net
Gross
Ship. vol. [m3]
180
49
113
81
92
51
78
1 1/2
3.6
4.0
0.00542
Technical data
Circulator pumps for domestic hot water
UPS 25-20 A p [kPa]
H [m]
20
2.0
180
1 x 230 V, 50 Hz
2
10
1.0
1
5
0.5
0
0.0 0.0
0.4
0.0
0.1
0.8
1.2
0.2
1.6
0.3
0.4
2.0 Q [m³/h]
0.5
Q [l/s]
TM00 8931 2105
1.5
TM00 9756 2405
3
15
Speed
P1 [W]
I1/1 [A]
3
65
0.26
System pressure:
Max. 10 bar
2
40
0.18
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.11
Energy class:
F
Dimensions [mm]
UPS 25-20 A
25
2.5
Weights [kg]
L1
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
65
49
112
61
65
1 1/2
3.5
3.7
0.0053
UPS 25-30 A H [m]
3/4" or 1" unions and valves
L
Pump type
p [kPa]
Connections:
180
1 x 230 V, 50 Hz
3
15
1.5
10
1.0
5
0.5
0
0.0
1
0.0
0.0
0.5
0.1
1.0
0.2
0.3
1.5
0.4
2.0
0.5
0.6
2.5
0.7
Q [m³/h]
0.8
Q [l/s]
TM00 8931 2105
2.0
2
TM00 9748 0397
20
Speed
P1 [W]
I1/1 [A]
3
55
0.24
System pressure:
Max. 10 bar
2
40
0.16
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.10
Energy class:
D
Pump type UPS 25-30 A
Connections:
3/4" or 1" unions and valves
Dimensions [mm]
Weights [kg]
L
L1
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
65
49
112
61
65
1 1/2
3.5
3.7
0.0053
25
Technical data
Circulator pumps for domestic hot water
UPS 25-40 A p [kPa]
H [m]
40
4
180
1 x 230 V, 50 Hz
3 2
30
3
20
2
10
1
0
0 0.5
0.0
1.0
0.2
1.5
2.0
0.4
2.5
0.6
Q [m³/h]
0.8
Q [l/s]
TM00 9749 2405
0.0
TM00 8931 2105
1
Speed
P1 [W]
I1/1 [A]
3
45
0.20
Connections: System pressure:
3/4" or 1" unions and valves Max. 10 bar
2
35
0.16
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.12
Energy class:
B
Dimensions [mm]
Pump type UPS 25-40 A
Weights [kg]
L
L1
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
65
49
112
61
65
1 1/2
3.5
3.7
0.0053
UPS 25-60 A
180
p [kPa]
H [m]
50
5
2
40
4
1
30
3
20
2
10
1
0
0
1 x 230 V, 50 Hz
0.0
1.0
0.2
1.5
2.0
0.4
2.5
0.6
3.0
Q [m³/h]
0.8
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
70
0.30
System pressure:
Max. 10 bar
2
60
0.27
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
50
0.22
Energy class:
C
Pump type UPS 25-60 A
26
0.5
TM00 9751 2405
0.0
TM00 8931 2105
3
Connections:
3/4" or 1" unions and valves
Dimensions [mm]
Weights [kg]
L
L1
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
65
49
112
61
65
1 1/2
3.5
3.7
0.0053
Technical data
Circulator pumps for domestic hot water
GRUNDFOS COMFORT The water-conduction part of the pump is hermetically separated from the stator with a stainless-steel spherical separator. The motor can be separated from the pump housing, enabling easy maintenance and replacement. GRUNDFOS COMFORT is supplied with isolating shells.
Ambient and liquid temperatures Liquid temperature: +2 °C to +95 °C. It is recommended to keep the operating temperature lower than 65 °C to avoid lime precipitation. The ambient temperature should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing. Maximum system pressure PN 10: 1.0 MPa (10 bar).
TM01 9238 1500
Inlet pressure To avoid cavitation noise and damage to the pump bearing, the following minimum pressures are required at the pump suction port. Liquid temperature Inlet pressure
85 °C
95 °C
0.5 m head
2.8 m head
0.049 bar
0.27 bar
Fig. 10 GRUNDFOS COMFORT
Applications • Domestic hot-water systems in single- and twofamily houses • small heating systems • cooling and air-conditioning systems. Pumped liquids • Clean, thin, non-aggressive and non-explosive liquids without solid particles or fibres • cooling liquids, not containing mineral oil • domestic hot water • softened water. The kinematic viscosity of water is υ = 1 mm2/s (1 cSt) at 20 °C. If the circulator pump is used for a liquid with a higher viscosity, the hydraulic performance of the pump will be reduced. Example: 50 % glycol at 20 °C means a viscosity of approx. 10 mm2/s and a reduction of pump performance by approx. 15 %. When selecting a pump, the viscosity of the pumped liquid must be taken into consideration. Motor Enclosure class: IP 42. Insulation class: F.
27
Technical data
Circulator pumps for domestic hot water
80
UP 15-14 p [kPa]
1 x 230 V, 50 Hz
H [m] 1.2
H4 G
H3
1.0 0.8
0.4
0
0.0
L2 L1
0.6 4
TM01 8554 1602
8
0.0 0.00
0.1
0.2
0.04
0.3
0.4
0.08
TM01 9070 0503
0.2
Q [m³/h]
0.12
Q [l/s]
P1 [W]
I1/1 [A]
25
0.11
B1
H2
B2
H1
Connections:
Various fittings, see page 40
System pressure:
Max. 10 bar
Liquid temperature:
+2 °C to +95 °C (TF 95)
Dimensions [mm]
Pump type
L1
L2
H1
H2
H3
Weights [kg]
H4
B1
B2
G
Net
Ship. vol. [m3]
Gross
UP 15-14 B
80
–
25
13.5
133
–
79.5
84
Rp 1/2
1.00
1.12
0.0026
UP 15-14 BU
80
90
25
13.5
–
205
79.5
84
Rp 1/2
1.15
1.31
0.0034
UP 15-14 BT
80
–
25
13.5
155
–
79.5
84
Rp 1/2
1.05
1.24
0.0034
UP 15-14 BUT
80
90
25
13.5
–
205
79.5
84
Rp 1/2
1.16
1.32
0.0034
UP 20-14 p [kPa]
110
1 x 230 V, 50 Hz
H [m] 1.2
H4 H3
G
1.0 8
0.8
0.4
0
0.0
L1
0.6 4
0.00
0.2
0.04
0.3 0.08
0.4
Q [m³/h]
0.12
Q [l/s]
P1 [W]
I1/1 [A]
25
0.11
Pump type
28
0.1
B1
H2
B2
H1
Connections:
Various fittings, see page 40
System pressure:
Max. 10 bar
Liquid temperature:
+2 °C to +95 °C (TF 95)
Dimensions [mm] L1
H1
H2
H3
H4
TM01 8555 1602
0.0
TM01 9098 0503
0.2
Weights [kg] B1
B2
G
Net
Gross
Ship. vol. [m3]
UP 20-14 BX
110
25
21
133
–
79.5
84
G 1 1/4
1.20
1.35
0.0026
UP 20-14 BXU
110
25
21
–
205
79.5
84
G 1 1/4
1.35
1.51
0.0034
UP 20-14 BXT
110
25
21
155
–
79.5
84
G 1 1/4
1.25
1.44
0.0034
UP 20-14 BXUT
110
25
21
–
205
79.5
84
G 1 1/4
1.36
1.52
0.0034
Technical data
Circulator pumps for domestic hot water
UP 20-07 N p [kPa]
H [m]
6.0
0.6
150
1 x 230 V, 50 Hz
4.5 0.4 3.0 0.2
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Q [m³/h]
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
50
0.24
UP 20-07 N
1.0
5
0.5
0
0.0
0.0
Weights [kg]
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
150
25
100
75
43
11/4
2.1
2.3
0.004
0.5
0.1
1.0
0.2
0.3
1.5
2.0
0.4
0.5
Q [m³/h]
0.6 Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
65
0.28
UP 25-15 N
+2 °C to +110 °C (TF 110)
150
0.0
Pump type
Max. 10 bar
Liquid temperature:
1 x 230 V, 50 Hz
TM00 8932 2105
10
3/4" or 22 mm unions and valves
System pressure:
L
UP 20-15 N H [m]
Connections:
Dimensions [mm]
Pump type
p [kPa]
TM00 9760 0397
0.0
TM00 9765 0397
0.0
TM00 8932 2105
1.5
Connections:
3/4" or 22 mm unions and valves
System pressure:
Max. 10 bar
Liquid temperature:
+2 °C to +110 °C (TF 110)
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
150
28
100
75
43
1 1/4
2.1
2.3
0.004
29
Technical data
Circulator pumps for domestic hot water
H [m]
30
3.0
20
2.0
10
1.0
0
0.0 0.0
0.5
0.0
1.0
1.5
0.2
2.0
0.4
2.5
0.6
Q [m³/h]
0.8
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
75
0.31
UP 20-30 N
3/4" or 22 mm unions and valves
System pressure:
Max. 10 bar
Liquid temperature:
+2 °C to +110 °C (TF 110)
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
150
28
100
75
43
1 1/4
2.1
2.3
0.004
UP 20-45 N
150
1 x 230 V, 50 Hz
4
30
3
20
2
10
1
0
0
0.0
0.5
1.0
0.2
1.5
2.0
0.4
0.6
2.5
3.0
0.8
3.5
Q [m³/h]
1.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
115
0.50
Pump type UP 20-45 N
TM00 9759 2405
40
TM00 9388 2105
H [m]
0.0
30
Connections:
Dimensions [mm]
Pump type
p [kPa]
1 x 230 V, 50 Hz
TM00 8932 2105
p [kPa]
150
TM00 9752 0397
UP 20-30 N
Connections:
3/4" or 22 mm unions and valves
System pressure:
Max. 10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
150
28
123
82
51
1 1/4
4.0
4.3
0.004
Technical data
Circulator pumps for domestic hot water
UPS 25-40 B p [kPa]
H [m]
40
4
180
1 x 230 V, 50 Hz
3 2
30
3
20
2
10
1
0
0 0.5
0.0
1.0
1.5
0.2
2.0
0.4
2.5
0.6
Q [m³/h]
0.8
Q [l/s]
TM00 9749 2405
0.0
TM00 9386 2105
1
Speed
P1 [W]
I1/1 [A]
3
45
0.20
Connections: System pressure:
3/4", 1", 22 or 28 mm unions and valves Max. 10 bar
2
35
0.16
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
25
0.12
Energy class:
B
Dimensions [mm]
Pump type UPS 25-40 B
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
102
75
51
1 1/2
2.9
3.1
0.004
UPS 25-60 B p [kPa]
H [m]
50
5
2
40
4
1
30
3
20
2
10
1
0
0
Weights [kg]
L
180
1 x 230 V, 50 Hz
0.0
0.5
1.0
0.2
1.5
2.0
0.4
2.5
0.6
3.0
Q [m³/h]
0.8
Q [l/s]
TM00 9751 2405
0.0
TM00 9386 2105
3
Speed
P1 [W]
I1/1 [A]
3
70
0.30
System pressure:
Max. 6/10 bar
2
60
0.27
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
50
0.22
Energy class:
C
Cold-water version:
Type BK for –25 °C to +95 °C (TF 95)
Pump type UPS 25-60 B
Connections:
3/4", 1", 22 or 28 mm unions and valves
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
102
75
51
1 1/2
2.9
3.1
0.004
31
Technical data
Special versions
UP 25-80 B p [kPa] 80
H [m]
70
7
60
6
50
5
40
4
30
3
20
2
10
1
0
0
180
2
0.0
3
0.5
4
5
1.0
6
7
1.5
8
Q [m³/h]
2.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
190
0.83
Connections:
3/4”, 1", 22 or 28 mm unions and valves
System pressure:
Max. 10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Energy class:
D
Dimensions [mm]
UP 25-80 B
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
130
82
52
1 1/2
4.2
4.5
0.008
Pump type
UPS 32-80 B
180
1 x 230 V, 50 Hz
H [m] 8
3 2
7 60
TM00 9387 2105
1
TM00 9758 2405
8
0
p [kPa] 80
1 x 230 V, 50 Hz
6 5
40
1
4 3
1 0
0 0
0.0
2
0.5
3
4
1.0
5
6
1.5
7
2.0
8
9
2.5
10
Q [m³/h]
3.0
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
240
1.05
2
205
0.91
1
Pump type UPS 32-80 B
32
1
135
TM00 8945 2105
2
TM00 9753 2405
20
Connections:
0.62
1 1/4", 28 or 42 mm unions and 1 1/4” valves
System pressure:
Max. 10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Energy class:
D
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
39
130
82
60
2
5.2
5.5
0.0102
Technical data
Special versions
UPS 32-50 FB p [kPa]
H [m]
50
5
40
4
30
3
20
2
10
1
0
0
220
1 x 230 V, 50 Hz
3 2
1
0.0
2
3
0.5
4
5
1.0
6
1.5
7
8
2.0
9
Q [m³/h]
2.5
Q [l/s]
TM00 9332 2105
0
TM00 9755 2405
1
Speed
P1 [W]
I1/1 [A]
3
115
0.51
Connections:
2
110
0.48
System pressure:
Max. 6/10 bar
1
85
0.38
Liquid temperature:
–25 °C to +110 °C (TF 110)
Energy class:
C
Dimensions [mm]
Pump type UPS 32-50 FB
H [m]
50
5
40
4
30
3
20
2
10
1
0
0
Weights [kg]
L
H1
H2
B1
B2
220
60
130
82
65
UPS 40-50 FB p [kPa]
1 1/2" screwed flanges or 40 mm flanges for welding
G
Net
Gross
Ship. vol. [m3]
5.3
5.6
0.008
250
1 x 230 V, 50 Hz
3 2
0.0
1
2
0.5
3
4
5
1.0
6
1.5
7
8
2.0
9
2.5
Q [m³/h]
Q [l/s]
TM00 9333 2105
0
TM00 9755 2405
1
Speed
P1 [W]
I1/1 [A]
3
115
0.51
2
110
0.48
System pressure:
Max. 6/10 bar
0.38
Liquid temperature:
–25 °C to +110 °C (TF 110)
Energy class:
C
1
Pump type UPS 40-50 FB
85
1 1/2" screwed flanges or 40 mm flanges for welding
Connections:
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
250
75
130
82
75
G
Net
Gross
Ship. vol. [m3]
9.3
9.7
0.0122
33
Technical data
Special versions
Product range, special versions Pump type
50 Hz 1 x 230 V
UP 25-25
z
UP 32-25
z
UPS 25-20
z
UPS 32-20
z
UPS 25-40
z
UPS 32-40
z
UPS 25-50
z
UPS 32-50
z
UPS 25-60
z
UPS 32-60
z
UP 25-80
z
UP 32-80
z
UP 20-07 N
z
UP 20-15 N
z
UP 20-30 N
z
UP 20-45 N
z
UP 32-80 B
z
UP 40-50 FB
z
UP 20-30 NK
z
50 Hz 3 x 220 V
60 Hz 3 x 440 V
60 Hz 1 x 220 V
z
z
UP 25-80
z
UP 32-80
34
50 Hz 3 x 400 V
UPSD 32-50 F
z
UPSD 32-80 F
z
UPSD 40-50 F
z
UPSD 40-80 F
z
UP 25-72
z
UP 40-72
z
UP 20-62 N
z
UPS 25-42
z
UPS 25-62
z
UPS 20-32 N
z
Technical data
Special versions
UPSD 32-50 F
50
5
40
4
30
3
20
2
10
1
0
0
3 2
1
0
1
0.0
2
3
0.4
4
0.8
5
1.2
Q [m³/h]
1.6
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
110
0.47
2
100
0.46
System pressure:
Max. 6/10 bar
0.37
Liquid temperature:
–25 °C to +110 °C (TF 110)
1
80
UPSD 32-50 F
p
H [m]
Weights [kg]
L1
L2
L3
L4
H1
H2
B1
B2
B3
Net
Gross
Ship. vol. [m3]
220
125
95
82
70
130
134
119
128
12.6
13.0
0.0126
UPSD 32-80 F
[kPa]
1 1/4" screwed flanges or 32 mm flanges for welding
Connections:
Dimensions [mm]
Pump type
60
TM00 9396 2105
H [m]
1 x 230 V, 50 Hz
TM00 9768 2405
p [kPa]
220
220
1 x 230 V, 50 Hz
3 2
6 5
45 4 30
1
3 2
0 0
0.0
1
2
3
4
0.5
5
1.0
6
1.5
Q [m³/h]
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
245
1.04
2
210
0.92
1
Pump type UPSD 32-80 F
140
TM00 9335 2105
1 0
TM00 9769 0397
15
1 1/4" screwed flanges or 32 mm flanges for welding
Connections:
0.63
System pressure:
Max. 6/10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Dimensions [mm]
Weights [kg]
L1
L2
L3
L4
H1
H2
B1
B2
B3
Net
Gross
Ship. vol. [m3]
220
125
95
82
70
130
134
119
128
12.6
13.0
0.0126
35
Technical data
Special versions
UPSD 40-50 F
p
H
[kPa]
[m] 5
250
1 x 230 V, 50 Hz
3
45
2
4 30
3
1
2 15
0 0
2
0.0
0.5
4
6
1.0
8
1.5
2.0
10 Q [m³/h]
2.5
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
140
0.60
2
130
0.57
1
90
UPSD 40-50 F
0.40
60
6
System pressure:
Max. 6/10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Weights [kg]
L1
L2
L3
L4
H1
H2
B1
B2
B3
Net
Gross
Ship. vol. [m3]
250
150
100
82
75
130
134
119
128
14.1
14.5
0.0126
UPSD 40-80 F
H [m]
1 1/2" screwed flanges or 40 mm flanges for welding
Connections:
Dimensions [mm]
Pump type
p [kPa]
TM00 9335 2105
0
TM00 9767 0397
1
250
1 x 230 V, 50 Hz
3 2
5 45 4 1
30
3 2
0 0
0.0
0.5
4
6
1.0
8
1.5
2.0
10 Q [m³/h]
2.5
Q [l/s]
1 1/2" screwed flanges or 40 mm flanges for welding
Speed
P1 [W]
I1/1 [A]
3
240
1.05
System pressure:
Max. 6/10 bar
2
205
0.91
Liquid temperature:
–25 °C to +110 °C (TF 110)
1
135
0.62
Pump type UPSD 40-80 F
36
2
TM00 8972 2105
1 0
TM00 9766 0397
15
Connections:
Dimensions [mm]
Weights [kg]
L1
L2
L3
L4
H1
H2
B1
B2
B3
Net
Gross
Ship. vol. [m3]
250
150
100
82
75
130
134
119
128
14.1
14.5
0.0126
Technical data
Special versions
UP 20-62 N p [kPa]
150
3 x 440 V, 60 Hz
H [m] 7
60
6 5
45 4 30
3
TM00 8964 2105
2 15
0
TM00 9764 0397
1 0 0
1
2
0.0
3
4
0.5
5 Q [m³/h]
1.0
Q [l/s]
P1 [W]
Speed 1
Connections:
I1/1 [A]
180
0.30
Max. 10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Dimensions [mm]
UP 20-62 N
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
150
26
123
80
51
1 1/4
4.0
4.3
0.008
Pump type
UP 25-72 p [kPa]
3/4" or 22 mm unions and valves
System pressure:
180
3 x 440 V, 60 Hz
H [m] 7
60
6 5
45 4 30
3 2
TM00 9762 0397
1 0
0 0
0.0
1
2
0.5
3
4
5
1.0
6
1.5
7
2.0
Q [m³/h]
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
185
0.31
Pump type UP 25-72
TM00 8960 2105
15
Connections:
3/4" or 1" unions and valves
System pressure:
Max. 10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
130
80
52
1 1/2
4.3
4.6
0.008
37
Technical data UP 40-72 F p [kPa]
250
3 x 440 V, 60 Hz
H [m] 7
60
6 5
45 4 30
3 2
0
0 0
1
0.0
2
3
0.5
4
1.0
5
6
7
1.5
8
2.0
9
10 Q [m³/h]
2.5
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
230
0.35
4.0
Max. 10 bar
Liquid temperature:
–25 °C to +110 °C (TF 110)
Weights [kg]
H1
H2
B1
B2
Net
Gross
Ship. vol. [m3]
250
65
130
80
65
7.4
7.8
0.0122
UPS 25-42
40
System pressure:
Dimensions [mm]
UP 40-72 F
H [m]
1 1/2" screwed flanges or 40 mm flange for welding
Connections:
L
Pump type
p [kPa]
TM00 8962 2105
1
TM00 9763 0397
15
180
1 x 220 V, 60 Hz
3
35 30
3.0 2
25 20
2.0
15
0
0.0 0.0
0.0
1.0
0.2
1.5
0.4
2.0
0.6
2.5
3.0
3.5
0.8
1.0
Q [m³/h]
Q [l/s]
Speed
P1 [W]
I1/1 [A]
3
85
0.40
2
50
0.26
1
Pump type UPS 25-42
38
0.5
30
TM00 9386 2105
1
1.0
5
TM01 0152 0597
10
3/4" or 22 mm unions and 3/4” or 22 mm valves
Connections:
0.15
System pressure:
Max. 10 bar
Liquid temperature:
+2 °C to +110 °C (TF 110)
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
102
75
51
1 1/2
2.6
2.8
0.004
Technical data UPS 25-62 H [m]
50
5
40
4
30
3
20
2
10
1
0
0
3
2
1
0.0
0.0
0.5
0.1
1.0
0.2 0.3
1.5
0.4
2.0
2.5
0.5 0.6
0.7
3.0
3.5
0.8 0.9
Q [m³/h]
1.0
1.1 Q [l/s]
TM00 9386 2105
6
TM01 0153 0597
60
1 x 220 V, 60 Hz
Speed
P1 [W]
I1/1 [A]
Connections:
3/4" or 1" unions and valves
3
115
0.51
System pressure:
Max. 10 bar
2
65
0.30
Liquid temperature:
+2 °C to +110 °C (TF 110)
1
35
0.17
Dimensions [mm]
UPS 25-62
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
180
32
102
75
51
1 1/2
2.6
2.8
0.004
H [m]
30
3.0
20
2.0
10
1.0
0
0.0 0.0
0.0
150
0.5
1.0
0.2
1.5
0.4
2.0
2.5 Q [m³/h]
0.6
Q [l/s]
Speed
P1 [W]
I1/1 [A]
1
95
0.43
Pump type UP 20-32 N
1 x 220 V, 60 Hz
TM00 8932 2105
UP 20-32 N p [kPa]
Weights [kg]
L
Pump type
TM01 0154 0597
p [kPa]
180
3/4" or 22 mm unions and 3/4" or 22 mm valves
Connections: System pressure:
Max. 10 bar
Liquid temperature:
+2 °C to +110 °C (TF 110)
Dimensions [mm]
Weights [kg]
L
H1
H2
B1
B2
G
Net
Gross
Ship. vol. [m3]
150
28
100
75
43
1 1/4
2.1
2.3
0.004
39
Accessories
Series 100
Pipe connections Unions
20-xx
G 1 1/4
N, B
25-xx 32-xx
1/2
3/4
z
z
z
G 1 1/2
B
1 1/4
1
z
z
3/4
z
1
1 1/4
z
z
∅22
∅28
∅10 ∅12 ∅15 ∅18 ∅22 ∅28 ∅42
z
TM00 9677 2097
TM00 9680 5196
mm
TM00 9679 5196
1 1/4
G2
B
1
mm
TM00 9678 5196
TM00 9681 2097
Pump connection
Pump type
Rp
R
Rp
Flanges
Pump type 21-xxF
Oval
36-xxF
Square
32-xxF
PN 6 PN 10
40-xxF
PN 6 PN 10 PN 6 PN 10
B B
z = Cast iron = Brass/bronze
40
3/4
1
z
z
1 1/4 1 1/2 1/2 z
z
3/4
1 1 1/4 ∅22
∅28
Rp (mm)
3/4 1 1 1/4 1 1/2 2 ∅32 ∅40 ∅50 1 1/4
1
TM00 9686 5196
TM00 9684 2097
TM00 9683 5196
TM00 9682 5196
Pump connection
Rp (mm)
mm
TM00 9685 5196
Rp Rp
∅32 ∅40
z
z
z
z
z
z
z
z z z
z z z z
z z
Accessories
Series 100
Grundfos controls TS 3: On/off time switch The on/off time switch is designed for wall mounting. The time switch automatically switches the pump on/off at preset intervals. It is available with 24-hour or week dial. Time switch
Product number 1 x 220 V
TS 3/T
24-hour dial
96406992
TS 3/W
Week dial
96406993
I TM01 0205 2602
Type
Fig. 11 TS 3
ST 200: On/off time switch and timed speed control The ST 200 control is designed to control all singlephase UP and UPS pumps. The control automatically changes over from one speed to another at preset intervals or only switches on/off (according to wiring). Product number 1 x 220 V
ST 200
24-hour dial
60041110
ST 200/TG
24-hour dial with battery back-up
60041210
ST 200/WG
Week dial with battery back-up
60041310
TM00 5142 5094
Time switch
Fig. 12 ST 200
SAT 200: On/off time switch and timed speed control The SAT 200 control has the same functions as the above-mentioned ST 200 control, but in addition, the SAT 200 features a built-in fuse and shorter intervals. Product number 1 x 220 V
Type
Time switch
SAT 200/TG
24-hour dial with battery back-up
60010210
SAT 200/WG
Week dial with battery back-up
60010310
12
9
3
6
TM00 5143 5094
Type
Fig. 13 SAT 200
41
Accessories
Series 100
GES 200: Timed changeover between pump heads The GES 200 control is designed to control all singlephase twin-head pumps. The control automatically changes over between the two pump heads at preset intervals.
Type
Time switch
GES 200/WG
Week dial with battery back-up
TM00 9103 4396
By selecting different speeds for the duty pump and the standby pump, a speed control facility can be obtained (e.g. left pump on speed 3, right pump on speed 2). Product number 1 x 220 V 60020310
Fig. 14 GES 200/WG
ET 2: Temperature switch The ET 2 temperature switch can be used in conjunction with ST 200, SAT 200 and GES 200 controls. The ET 2 is a switch controlling according to the outdoor, room, flow-pipe or return-pipe temperature. Control signal
Temperature (outdoor, room, flow pipe, return pipe)
Type
ET 2
Temperature switch
Product number
With housing and outdoor sensor
ID4383
With sensor for external pipe mounting
ID4384
With sensor for internal pipe mounting and bushing
ID4385
Differential-pressure controls are also available. Terminal block The terminal block is fitted to the terminal box and used for the connection of external controls (e.g. for external changeover between two speeds).
Terminal block
Product number TM00 5144 5094
Type
605003
Fig. 15 Terminal block
42
Accessories
Series 100
Pump type ALPHA2 25-40, 25-40 A, 25-50, 25-60, 25-60 A ALPHA+ 25-40, 25-40 A, 25-60, 25-60 A
ALPHA2 25-40 N, 25-60 N ALPHA+ 25-40B, 25-60 B
ALPHA2 32-40, 32-60 ALPHA+ 32-40, 32-60
Service kit for ALPHA2 and ALPHA+
Description
Material
Product number
3/4" unions
Cast iron
529921
1 " unions
Cast iron
529922
Brass
519805
3/4" valves 1 " valves
Brass
519806
3/4" unions
Brass
529971
1 " unions
Brass
529972
3/4" valves
Brass
519805
1 " valves
Brass
519806
1 " unions
Cast iron
509921
1 1/4" unions
Cast iron
509922
TM01 9911 3400
Union and valve kits
Insulation kits Series 100 can be fitted with two insulating shells. The thickness of the insulating shells corresponds to the nominal diameter of the pump. The insulation kit, which is tailored to the individual pump type, encloses the entire pump housing. The two shells are easily fitted around the pump.
Fig. 17 Plug Description
Product number
Plug - ALPHA2 and ALPHA+
595562
Timer and thermostat for COMFORT According to the table below, the pump types B, BT, BX and BXT can be upgraded with a 24-hour timer. The timer for the pump types BT and BXT includes a thermostat for replacement.
Fig. 16 Insulating shells
ALPHA2 and ALPHA+ XX-40, XX-50, XX-60
Product number
UP 15-14 BUT
ALPHA2 and ALPHA+ 25-40 A, 25-60 A
505822
UP 20-14 BX
UPS 25-20
505821
UP 20-14 BXU
UPS 32-20
505821
UP 20-14 BXT
UPS 25-30
505821
UPS 32-30
505821
UPS 25-40
505821
UPS 32-40
505821
UPS 25-60
505821
UPS 32-60
505821
UPS 25-80
525242
UPS 32-80
525242
UPS 25-20 A
505822
UPS 25-30 A
505822
UPS 25-40 A
505822
UPS 25-60 A
505822
UPS 40-50 F
525243
UPS 25-40 B
505821
UPS 25-60 B
505821
UP 25-80 B
525242
UPS 32-80 B
525242
UPS 40-50 FB
525243
UP 20-14 BXUT
24-hour timer + thermostat
96433891 z z
UP 15-14 BT
505821
Product number
24-hour timer
Isolating valve and non-return valve
UP 15-14 B UP 15-14 BU
Insulation kit for pump type
Thermostat
Pump type
24-hour timer
TM03 9505 4107
Supplied with
z
96433892
z z
z z
96433891
z z
z
z
z
96433892
43
Accessories
Series 100
44
Product number
TM01 8539 0300
Extension set Length = 35 mm each
Rp 1/2 / G 1 1/4
Brass
96433911
TM01 8540 0300
Extension set Length = 25 mm each
Rp 1/2 / G 1 1/2
Brass
96433912
TM01 8541 0300
Extension set Length = 30 mm each
Rp 1/2 / G 1
Brass
96433913
TM01 8647 0300
Non-return valve
1/2
Brass
96433904
TM01 8648 0300
Isolating valve
1/2
Brass
96433905
TM01 8542 0300
Extension set Length = 40 mm
G 1 1/4 / G 1 1/4
Brass
96436559
TM01 8643 0300
UP 15-XX UP 20-XX
Material
Union set
G 1 1/4 x 15 mm int. / R 1/2 ext.
Brass
96433907
TM01 8644 0300
UP 20-XX
Connection
Union set
G 1 1/4 x Rp 3/4 int.
Brass
96433908
TM01 8645 0300
UP 15-XX
Fitting
Description
Union set
G 1 1/4 x Rp 1/2 int. / R 3/4 ext.
Brass
96433909
Union set
G 1/4 x 22 mm int.
Brass
96433910
Flange Union nut Hose
PP CuZn40Pb2 PE
96433906
TM01 8560 0300
Pump type
TM01 8646 0300
Fittings for COMFORT
Venting flange
Further product documentation WebCAPS
Series 100
WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalogue • Literature • Service • Sizing • Replacement • CAD drawings.
Catalogue This section is based on fields of application and pump types, and contains • technical data • curves (QH, Eta, P1, P2, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation • product photos • dimensional drawings • wiring diagrams • quotation texts, etc.
Literature In this section you can access all the latest documents of a given pump, such as • data booklets • installation and operating instructions • service documentation, such as Service kit catalogue and Service kit instructions • quick guides • product brochures.
Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.
45
Further product documentation
Series 100
Sizing
0
1
This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. • analyse your selected pump via the built-in life cycle cost tool • determine the flow velocity in wastewater applications, etc.
Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.
CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: • .dxf, wireframe drawings • .dwg, wireframe drawings. 3-dimensional drawings: • .dwg, wireframe drawings (without surfaces) • .stp, solid drawings (with surfaces) • .eprt, E-drawings.
WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 18 WinCAPS CD-ROM
46
47
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence
V7124413 1207 Repl. V7124413 1105
GB
GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00 www.grundfos.com
Subject to alterations.