Transceiver
CONTENTS
Transceiver Mini Series Mini OTDE-BFOC
6
Mini OTDE-FSMA
6
Mini UTDE-RJ45
6
Mini KTDE-BNC
6
Standard Series KTDE-V
8
KTDE-N
8
Channel Series KTDE-BNC (UP)
10
TRANSCEIVER
Hirschmann offers a complete system - ranging from the pure ethernet hub, FDDI concentrators, switches, bridges and routers to Fast ethernet and gigabit ethernet switches, all complete with single unit management. To complete the range, we offer transceivers, stand alone products, management and diagnostic software as well as accessories and manuals.
Hirschmann Transceivers enable the direct connection of end user machines onto a 10 Mbit/s CSMA/CD-LAN to IEE 802.3 standard. Whilst the compact optical mini transceiver uses BFOC or FSMA connections to connect directly onto the PC workstations AUI interface and any peripheral machines, standard transceivers and cable transceivers are installed using a coax segment. In this way savings can be made on expensive AUI cable and at the same time more economical extensive diagnostic options are available as well as integrated functions for security and durable network housing.
Hirschmann products attain the highest CE classification as well as all current VDE, SNMP, ANSI ISO and IEEE standards. This is exhaustively controlled during tests. Last but not least, the user friendliness of the network is of fundamental importance when it comes to building a modern network.
The high level of networking in the office environment makes it essential for a company to have a completely reliable user terminal connection; no firm can afford an inefficient network, let alone endure system crashes.
Whether coaxial, fibre optic or twisted pair technology, Hirschmann transceivers not only offer a secure connection between work group hubs and the company backbone, but also offer access from an external switch, to SQE-/Heart Beat Test as well as status and diagnostic LEDs.
Whenever it introduces a new product onto the market, Hirschmann gets closer to its ultimate aim of solving the most difficult task of customer orientated total quality management. Studies of customer satisfaction and the intensive exchange with users provide useful pointers.
Hirschmann transceivers are chosen as communications
Hirschmann offers solutions which are based on market needs. Customised, without any superfluous technical fittings, and with well thought out details to minimise total costs. They give you the certainty that they will suit any future requirements and therefore guarantee a high degree of investment protection.
During normal industrial operation, networks need to work
components for transporting information technology, because such networks themselves need to operate under severe environmental conditions. A further factor is the capacity to connect stations over great distances using LWL cable.
under the most critical environmental conditions: electromagnetic disturbance, heavy flows and atmospheric changes, high pollution, large temperature fluctuations or mechanical pressures. It is precisely for those very reasons that Hirschmann network components are developed for durability and reliability. They have to be mechanically sound, maintenance free and simple to install. Hirschmann transceivers are a good example of this commitment having been developed for use in a worst case scenario, so that they can be installed even in critical environmental conditions. Their ability to prevent system crashes has been proven time and again during independent MTBF studies.
5
The Hirschmann Mini Transceiver enables direct connection onto end user stations by using 10 Mbit/s CSMA/CD LAN to IEEE 802.3 standards in coaxial, fibre optic or twisted pair technology. The mini transceivers are so compact that they can be connected directly onto the AUI interfaces of PCs, work stations or peripheral units. In this way
• Connectable directly on to the user terminal which saves on expensive transceiver cabling • Extensive diagnostic possibilities through LEDs which simplify error searching. • Robust metal casing
you can save on the costs and avoid using expensive AUI cabling. The mini transceiver has an additional external display for SQE /Heart beat test, status and diagnostic LEDs as well as an integral Jabber protection function. The mini transceiver, Mini OTDE , comes as two versions, both with
BNC and the Mini UTDE is fitted with an RJ45 socket.
ASGE 1-RE
ECFL4 UYDE MIKE
Mini-UTDE
CYDE
MINI SERIES
BFOC and with FSMA connectors. The Mini KTDE is fitted with a
TP FO Mini-OTDE
COAX Mini-OTDE Mini-WG 8TP
BNCT-adapter Mini-KTDE
Mini Transceiver
Compact transceiver for safe user terminal connection onto fibre optic, twisted pair and coax or for the connection of work group hubs and on to the company backbone.
Product
Order No.
MINI OTDE-BFOC
943 303-021
MINI OTDE-FSMA
943 303-001
Operating voltage
+10,75 V to +15,75 V
Current
type 200 mA
Interfaces
10BASE-FL
- LWL interfaces
2 BFOC sockets IEC 874-10 or 2 FSMA sockets IEC 874-2
Transceiver interface
1 AUI port (15 pole sub D socket)
Operating distance
50/125 µm cable: 2,000 m/ca 11 dB
Distance degradation
62.5/125 µm cable: 3,000 m/ca 14 dB
Number of LEDs
P Power, TX Send data, RX
MINI OTDE-BFOC
receiving Data, CD collision detect, LS link status - Measurements W x H x D
44 x 21 x 91 mm
- Weight
130 g
- Operating temperature
0 °C to + 50 °C
Product
Order No.
MINI-UTDE-RJ45
943 270-001
Operating voltage
+10 V to +16 V
Current
type 38 mA
Interfaces
10BASE-T
- TP interfaces
8 pole screened RJ45 socket
- Transceiver interface
1 AUI port (15 pole sub D plug)
Operating distances
1 screened or unscreened twisted pair cable segment with a distance diminishing 11.5 dB at 5-10 Mhz (ZL = 100 Ω)
Display LEDs
MINI UTDE-RJ45
P Power, TX-DA sending data, CD collision detect, RX-DA Receiving data, LINK, APX
- Measurements W x H x D
44 x 21 x 82 mm
- Weight
130 g
- Operating temperature
0 °C to + 50 °C
Product
Order No.
MINI-KTDE-BNC
943 331-001
Operating voltage
+10 V to +16 V
Current
type 250 mA
Interfaces
10BASE2
- Coax interface
1 BNC socket
- Transceiver interface
1 AUI port (15 pole sub D plug)
Operating distances
1 coax segment max. 185 m long
Display LEDs
P Power, send / receive data, CD collision detect
- Measurements W x H x D
44 x 21 x 100 mm
- Weight
130 g
- Operating temperature
0 °C to + 50 °C
Accessories
Order No.
Wall holder for the
943 426-001
MINI KTDE-BNC
Mini transceiver
7
The standard Hirschmann transceiver enables connection to PCs, work stations or peripherals on a coax segment of a 10 Mbit/s CSMA/CD LAN using the IEEE 802.3 standard. The standard transceiver has an external display for the SQE / Heart Beat Test,
• Reliable transceivers to high quality assurance standards • Extensive diagnostic options with LEDs, which simplify error searches
status and diagnostic LEDs as well as an integrated Jabber protect
S TA N D A R D S E R I E S
function. The coax transceiver has two variations. The KTDE-V with a vampire clip and the KTDE-N with two N sockets.
KTDE-N KTDE-V
KTDE-N KTDE-V
AUI AUI
Mini-WG 8TP
TP
Standard Transceiver
Connection to the end user machine on coax segment (10Base5) or connection from work group hubs using coax
Product
Order No.
KTDE-V
943 258-001
Operating voltage
+10 V to +16 V
Current
type 250 mA (12 V without signal)
Interfaces
10BASE 5
- coax interfaces
1 cable piercing tap (vampire clip)
- Transceiver interfaces
1 AUI port (15 pole sub D plug)
Operating distances
1 coax segment max. 500 m long
Display LEDs
P Power, DA data, CD collision Detect
KTDE-N
Construction - Measurements W x H x D
100 x 33 x 92 mm
- Weight
480 g
- Operating temperature
0° C to + 50 °C
Product
Order No.
KTDE-N
943 259-001
Operating voltage
+10 V to +16 V
Current
type. 250 mA (12 V without signal)
Interfaces
10base5
- Coax interface
2 N sockets
- Transceiver interface
1 AUI port (15 pole Sub D plug)
Operating distances
1 coax segment max. 500 long
Display LEDs
P Power, DA data, CD collision detect
Construction - Measurements W x H x D
100 x 33 x 92 mm
- Weight
480 g
- Operating temperature
0 °C to + 50 °C
KTDE-V
9
CABLE CHANNEL SERIES
The Hirschmann cable channel transceiver
KTDE-BNC (UP)..
allows for the connection of PCs, work stations or peripherals onto a coax segment of a 10 Mbit/s CSMA/CD LAN to the IEEE 802.3 standard.
• By using built in cable channels no additional units are required at the work place • The KTDE-BNC (UP) offers a completely secure connection.
The cable channel transceiver has an external display for the SQE/ Heart Beat Test, status and diagnostic LEDs as well as an integrated Jabber protect function. The KTDE-BNC (UP), which is built in to the installation channels, offers an alternative to fuse box technology, an absolutely reliable user terminal anchor. The coax transceiver KTDE-BNC (UP) connects to two BNC boxes.
Cable channel transceiver
KTDE-BNC (UP)
AUI
Cable Channel Transceiver
AUI
End user connection on a coax segment (10Base2) for the building of a cable channel
Product
Order No.
KTDE-BNC (UP)
943 157-001
Operating voltage
+10 V to +16 V
Current usage
typically 250 mA (12 V/without signal)
Interfaces
10Base2
- Coax interface
2 BNC sockets
- Transceiver interface
1 AUI port (15 pole Sub D plug)
Operating distance
1 coax segment max. 185 m long
LED displays
P Power DA Data, CD collision detect
Mechanical construction - Measurements W x H x D
86 x 86 x 50 mm
- Weight
320 g
- Operating temperature
0° C to + 50 °C
Product
Order No.
CD-ROM manual for German and
943 590-001
KTDE-BNC (UP)
English includes the following manuals in Acrobat Reader Format - Manual for Advanced LAN Switch Release 1.5 - Manual for ETHERNET Version 3.1 - Manual for Management MIKE Release 3.2 - Manual for Management MultiMIKE Release 1.2 - Manual for FDDI Version 2.0 - Manual for Token Ring Version 1.1 - Manual for Bridge/Router Plug-in module ERISDN - Manual for FDDI/ Ethernet-Switch/ Router Plug-in module Version 1.0 - Manual for Management FCMA Release 3.0 - Manual for MultiLAN Switch Release 2.1 - User Guide HiWay Fast ETHERNET and ETHERNET/Fast ETHERNET Workgroup Switches - Installation and Configuration Guide for ATM Uplink Module - Installation and Configuration Guide for FDDI-DAS Uplink Module - Users Manual for HiWay ETHERNET Workgroup Hub
11
Richard Hirschmann GmbH & Co Stuttgarter Straße 45 – 51 D-72654 Neckartenzlingen Tel ++49-7127-14-1527 Fax ++49-7127-14-1542 email:
[email protected] Internet: www.hirschmann.de Richard Hirschmann Ges.m.b.H. Breitenfurterstraße 250 A-1230 Wien Tel ++43-1-865-7841 Fax ++43-1-865-7841 Richard Hirschmann Electronique SA 24, rue du Fer à Cheval-Z.I. F-95200 Sarcelles Tel ++33-1-39330288 Fax ++33-1-39905968 email:
[email protected] Richard Hirschmann Electronics UK Ltd. Kingswick House Kingswick Drive GB-Sunninghill, Berkshire SL5 7BH Tel ++44-1344-292220 Fax ++44-1344-292227 email: birgitta
[email protected] Richard Hirschmann Electronica Nederland B.V. Postbus 92 NL-1380 AB Weesp Tel ++31-294462544 Fax ++31-294480639 email:
[email protected] Richard Hirschmann of America Inc. Industrial Row P.O.Box 229 USA-Riverdale, N.J. 07457 Tel ++1-973-8355002-220 Fax ++1-973-8358354 Hirschmann España S.A. Calle Albalá 7 E-28037 Madrid Tel ++34-1-7540208 Fax ++34-1-7545177
DS 280 720-789