Company References
Telecommunication United Kingdom
Project : International provider of fiber-based communications services to largest Internet carriers Installation description: n. 15 sites all-over Europe and Far East for data center cooling and monitoring by RC control system
Period: 2005 - 2010 Application: Data center End user name: Level (3) Communications – London (U.K.) Plant type: Free cooling and air cooled liquid chillers, chilled water and direct expansion CRAC units Total installed Cooling capacity: 41 MW Installed equipments: nr. 42 x free cooling liquid chillers in all European sites nr. 8 x air cooled liquid chillers, 5 in European and 3 in Far East sites nr. 454 x chilled water CRAC units in all European sites nr. 76 x direct expansion CRAC unit in Far East
Solution: MAXIMO, UNICO, PEGASUS
MAXIMO Free-cooling chillers
PEGASUS CRAC units
UNICO Air cooled chillers 2
Telecommunication Italy
Period: 2010 - 2012 Application: Data Center & Operational Building End user name: Vodafone - Milan (ITALY) Plant type: multifuntion chillers + TLC units Total installed Cooling capacity: 9.0 MW Project: leading European provider of mobile communications Installation description: the whole project is focused on sustainability, integration with the environment and on energy efficiency. The installation reflects a modern way of working, interactive and flexible, made possible by new technologies.
Installed equipments: Air cooled liquid chillers, packaged air conditioners for indoor or outdoor installation
Solution: flexibility of RC units with application for data storage & backup as well as for mobile TLC MINIPAC Air conditioners for outdoor installation
GLIDER Air cooled chillers ENERTEL Air conditioners for indoor installation
UNICO SCREW Air cooled chillers 3
Telecommunication Sweden Period: 2009 - 2011 Application: Data center End user name: Telecity Group - Stockholm (SWEDEN) Plant type: Free cooling chiller, water cooled chiller with magnetic levitation centrifugal compressors Total installed Cooling capacity: 10 MW Project : leading provider of premium network independent data centres in Europe Installation description: the units have been selected to maximize efficiency, to compliment the sustainable development of the whole building on Stockholm 1 & 2 sites Data Centre
Installed equipments: nr. 7 x free cooling chillers nr. 1 x water cooled chiller with magnetic levitation centrifugal compressor
Solution: GLIDER FREE, FRIGO TURBO FRIGO TURBO Water cooled chillers with centrifugal compressors
GLIDER FREE Free-cooling chillers
4
Data Center United Kingdom
Project : world's leading financial management and advisory companies, providing financial advice and investment banking services. Installation description: fully customized CRAC units & chillers supply for U.K. Data Centre & Offices cooling
Period: 2007 - 2010 Application: Data center End user name: Merrill Lynch – London (U.K.) Plant type: Free cooling, conventional and magnetic levitation centrifugal liquid chillers, chilled water CRAC units Total installed Cooling capacity: 30 MW Installed equipments: nr. 3 x air cooled liquid chillers, nr.12 x free cooling chillers nr. 8 x air cooled chillers with magnetic levitation centrifugal compressors nr. 90 x chilled water CRAC units
Solution: MAXIMO SCREW, UNICO TURBO, UNICO SCREW, NEXT CW NEXT CRAC units
MAXIMO SCREW Free-cooling chillers
UNICO SCREW Air cooled chillers
UNICO TURBO Air cooled chillers with centrifugal compressors
5
Data Center United Kingdom Period: 2009 - 2010 Application: Data center
End user name: Barclays Capital Plant type: Free cooling, air cooled and magnetic levitation centrifugal liquid chillers, CRAC units Total installed Cooling capacity: 16 MW Installed equipments: nr. 3 x air cooled liquid chillers, Project : International investment bank with presence in all major markets around the world. Installation description: system conceived for full reliability, high energy saving, low noise cooling of U.K. Data Centre & Offices
nr.12 x water cooled chillers with magnetic levitation centrifugal compressors nr. 3 x air cooled screw chillers nr. 52 x chilled water CRAC units
Solution: FRIGO TURBO, UNICO SCREW, NEXT CW
UNICOSCREW Air cooled chillers NEXT CRAC units
FRIGO TURBO Water cooled chillers with centrifugal compressors
6
Data Center Poland Period: March 2011 Application: MOTOROLA Server Rooms End user name: MOTOROLA (POLAND) Plant type: Chilled Water System Total installed cooling / heating capacity: 1200kW Installed equipments: nr. 2 x free cooling chillers nr. 1 x air cooled chiller
Project : MOTOROLA GREEN OFFICE Installation description: water cooled system + FREE COOLING
nr. 11 x CRAC units nr. 10 x CRAC units for blade servers
Solution: GLIDER, GLIDER FREE, NEXT CW, COOLSIDE CW
COOLSIDE CRAC units for blade server
NEXT CRAC units
GLIDER Air cooled chillers
GLIDER FREE Free coolibgchillers 7
Data Center Italy
Period: 2010-2011
Application: Data centre End user name: Unicredit Bank (ITALY) Plant type: Liquid chillers, chilled water CRAC units Total installed Cooling capacity: 5.6 MW
Project : leading international Italian bank with presence in all over Europe. Installation description: an example of single source responsibility where RC is supplying CRAC units and chillers for Verona Data Centre cooling
Installed equipments: nr. 1 x air cooled liquid chillers nr. 4 x water cooled liquid chillers nr. 206 x chilled water CRAC units with EC fans
Solution: UNICO SCREW, FRIGO SCREW, PEGASUS with EC fans for highest energy saving
UNICO SCREW Air cooled chillers
PEGASUS CRAC units
FRIGOSCREW Water cooled chillers
8
Office Buildings United Kingdom
Period: 2012 Application: Data center & operational building End user name: Fox Santander Bank – London (U.K.) Plant type: conventional air cooled chillers Total installed Cooling capacity: 10 MW Project: is a diversified retail and commercial bank with around 15,000 branches.
Installed equipments: nr. 20 x air / water cooled chillers
Installation description: system conceived for full reliability, high energy saving, low noise emission Solution: GLIDER, MANTA
GLIDER Air cooled chiller
MANTA Water cooled chiller
9
Office Buildings United Kingdom
Period: 2012 Application: Operational Building End user name: British Airways (U.K.) Plant type: conventional air cooled chillers Total installed Cooling capacity: 1.5 MW Installed equipments: nr. 2 x air cooled chillers with magnetic levitation centrifugal compressors Project : U.K. flag carrier airline and second largest measured by passengers carried. Installation description UNICO TURBO FL Solution: filling out the request of high efficiency using the magnetic levitation compressor
UNICO TURBO FL Air cooled chiller with centrifugal compressors
CQ212
10
Office Buildings Italy
Period: 2012 Application: Operational Building End user name: Aeronautica Militare Pozzuoli (ITALY) Plant type: multifunction chillers Total installed Cooling capacity: 0.6 MW Installed equipments: nr. 1 x multifunction chiller Project: heating and cooling request Installation description: strategic cooling of mission critical building Solution: MULTIPLO SCREW
MULTIPLO SCREW Multifunction chiller 11
Hotels Italy
Period: 2012 Application: congress centre End user name: Chia Laguna Resort – Sardinia (ITALY) Plant type: multifunction chillers
Total installed Cooling capacity: 0.7 MW Project: Luxury hotel with congress centre set in one of the most enchanting sceneries in Southern Sardinia.
Installed equipments: nr. 1 multifunction chiller
Installation description: request of heating and cooling performances at the same time to ensure highest energy efficiency and best comfort Solution: MULTIPLO SCREW
MULTIPLO SCREW Multifunction chiller 12
University Russia
Period: 2008 Application: Physics Researches Institute End user name: Moscow, Zelenograd (RUSSIA) Plant type: Free cooling chillers Total installed Cooling capacity: 6,5 MW Installed equipments: nr. 4 x air cooled chillers Project: University Campus Installation description: cooling supply Solution: MAXIMO SCREW
MAXIMO SCREW Free cooling chillers
13
Retail Belgium
Period: 2012 Application: CITY 2 End user name: COFELY Services Plant type: shopping centre – Brussels (BELGIUM) Total installed Cooling capacity: 2,4 MW Project: Located in “Rue Neuve”, in the heart of the city of Brussels, City 2, with its 51.000 m², is the largest urban shopping centre in Belgium.
Installed equipments: nr. 4 x air cooled chillers with magnetic levitation centrifugal compressors
Installation description: large surfaces comfort cooling by technological system focused on energy efficiency and low running costs Solution: UNICO TURBO FL
UNICO TURBO FL Air cooled chiller with centrifugal compressors
CQ212
14
Retail Italy
Period: 2012 Application: Milano Portello mall End user name: Vittoria Assicurazioni, Milano, Italy
Plant type: air cooled chillers Total installed Cooling capacity: 2,3MW Project: Milano Portello with its over 50 shops is one of the largest malls in Milano. Located in North-West part of the town , easily reachable, represents a usual aim for people living in Milano and suburbs.
Installed equipments: nr. 3 x air cooled chillers
Installation description: simultaneous production of hot and cold water . Solution: UNICO SCREW
UNICO SCREW Air cooled chillers
CQ212
15
Industry Sweden
Period: 2012 Application: Stora Enso industry End user name: Stora Enso, Skoghall, Sweden Plant type: water cooled chiller
Total installed Cooling capacity: 570kW Project: Stora Enso is the global re-thinker of the biomaterials, packaging, paper and wood products industry.
Installed equipments: nr. 1 water cooled chiller
Installation description: Double function of chilling (7°C) the mechanical equipment of wood treatment and re-using the heat coming from the gas condensation process to warm up (45°C ) the raw material transformed. Solution: MANTA 570
MANTA Water cooled chiller
CQ212
16
Office Buildings Luxemburg
Centre Drosbach by Indiact
Period: 2012 Application: Drosbach Centre End user name: Indiact, Luxemburg Plant type: water cooled chillers Total installed Cooling capacity: 1MW
Project: Drosbach is one of the largest office and congress centre in Luxemburg. Drosbach offers conference halls meeting rooms, dining halls as well as all necessary facilities for any kind of meeting.
Installed equipments: nr. 2 x water cooled chillers with magnetic levitation centrifugal compressors
Installation description: very high energy savings with the state of the art in terms of components for high tech liquid chiller machines Solution: FRIGO TURBO
FRIGO TURBO Water cooled chillers with centrifugal compressors
CQ212
17
Data Center Belgium Period: 2012 Application: Data center
End user name: Smals Data Center Plant type: liquid chillers, chilled water CRAC units Total installed Cooling capacity: 2.0 MW
Project: Smals is a hosting site for servers, mainly government in Brussels
Installed equipments: nr. 3 x A class water cooled chillers nr.27 x chilled water CRAC units
Installation description: The chillers, energy CLASS A matched to the chilled water CRAC units represent the best solution for any high energy saving large Data Centre Solution: FRIGO SCREW CLA, NEXT CW
NEXT CRAC units
FRIGO SCREW CLA Water cooled chillers
CQ212
18
Data Center Iran
Period: 2012 Application: Data Center End user name: TCI, Telecommunication Company of Iran, Iran Plant type: liquid chillers, chilled water CRAC units Total installed Cooling capacity: 500kW Project: Data Centre of TCI, public telecommunication company in Iran
Installed equipments: nr. 2 x air cooled chillers nr. 5 x chilled water CRAC units
Installation description: The installed chillers, matched to the chilled water CRAC units represent the best cost effective solution for small to medium Data Centre Solution: EAGLE, NEXT CW, HEAT HUNTER
EAGLE Air cooled chillers
CQ212
HEAT HUNTER CRAC units displacement type
NEXT CRAC units downflow type 19
Research Centre Italy Period: 2012 Application: Development Research Center End user name: Ericsson, Genoa, Italy Plant type: air cooled liquid chillers, chilled water CRAC units Total installed Cooling capacity: 1,5MW
Project: The most important Ericsson Development Research Center in Italy, one of the leading centers for ultra-fast broadband networks. Installation description: The installed units are the best answer to the need of precise thermo-hygrometric and air purity conditions granting the optimal environment for Ericsson equipments
Installed equipments: nr.20 x chilled water CRAC units
nr.1 x A class liquid chiller with magnetic levitation centrifugal compressor
Solution: NEXT CW , UNICO TURBO
NEXT CRAC units
UNICO TURBO Air cooled chillers
20
Conference Centre Belgium
Period: 2011 Application: Diamant Building End user name: Diamant, Brussels, Belgium Plant type: air cooled liquid chiller Total installed Cooling capacity: 1MW
Project: Diamant Brussels is a leading conference centre close to the centre of Brussels with twenty comfortable modular rooms with functional furniture.
Installed equipments: nr. 2 x A class air cooled liquid chiller equipped with magnetic levitation centrifugal compressors
Installation description: One of the most important characteristics of the installed units is the high energy efficiency granted by two stage centrifugal compressor with variable speed and magnetic levitation oil-free bearings. Solution: UNICO TURBO
UNICO TURBO Air cooled chillers
21
Business Centre Russia Period: 2011 Application: PREO 8 Business Centre
End user name: PREO 8, Moscow, Russia Plant type: air cooled and free cooling liquid chillers Total installed Cooling capacity: 7MW Project: PREO 8 is a new Business Centre, located in a historical district of Moscow, adjacent to Preobrazhenskaya Square metro station, offering Modern architectural solutions and efficient planning of the office spaces.
Installed equipments: nr.3 x air cooled liquid chillers nr.2 x free cooling liquid chillers
Installation description: the installed units grant high energy efficiency and reduced operating costs, two units are equipped with free cooling system. Solution: GLIDER, GLIDER FREE
GLIDER FREE Free-cooling chillers
GLIDER Air cooled chillers
22
Religious Centre Indonesia
Period: 2012 Application: Islamic Centre End user name: Jakarta, Indonesia Plant type: air cooled liquid chiller Total installed Cooling capacity: 3MW Project: The Islamic Centre of Jakarta with its multifunctional monumental building, voted to religion, education and business, acts as a point of reference and prototype for the Islamic Centres in Indonesia.
Installed equipments: nr.6 x A class air cooled liquid chiller
Installation description: the installed units grant high energy efficiency and reduced operating costs Solution: GLIDER CLA
GLIDER Air cooled chillers
CQ212
23
Retail South Africa Period: 2012 Application: Moolman Group, Makro Mangaung, Bloemfontein End user name: Makro Bloemfontein, South Africa Plant type: air cooled liquid chiller, air cooled heat pump liquid chiller Total installed Cooling capacity: 1MW Project: The new Makro store, developed by The Moolman Group, is located on the western side of Bloemfontein and attracts shoppers from all over the province and from neighboring Lesotho. Installation description: The heat pump chillers series are the ideal solution for those applications where the air conditioning is needed all year long, cooling in summer and heating in winter Solution: GLIDER, GLIDER HP
Installed equipments: nr.1 x air cooled liquid chiller nr.1 x air cooled heat pump liquid chiller
GLIDER Air cooled chillers
CQ312
24
Office Buildings Switzerland
Period: 2010 Application: Rolex HQ End user name: Rolex, Geneve Plant type: CRAC unit, chilled water CRAC unit Total installed Cooling capacity: 30kW
Project: Rolex SA is a Swiss watchmaking manufacturer of high-quality, luxury wristwatches. Rolex watches are popularly regarded as status symbol. Installation description: The installed units are the best answer to the need of a precise control of the thermohygrometric and air purity conditions, granting the optimal environment for electronic equipment to work. Solution: NEXT DW, NEXT CW
Installed equipments: nr.1 chilled water CRAC unit nr.1 CRAC unit
NEXT CRAC units
CQ410
25