POWER STORAGE SYSTEM STORAGE SYSTEM FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS

POWER STORAGE SYSTEM 5.7 | 7.6 | 9.6 | 11.5 STORAGE SYSTEM FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS German design More independence Modular batte...
Author: Benedict Woods
3 downloads 0 Views 703KB Size
POWER STORAGE SYSTEM 5.7 | 7.6 | 9.6 | 11.5 STORAGE SYSTEM FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS

German design More independence Modular battery technology Easy transportation and installation

TECHNICAL DATA PowER BATTERY High voltage, high efficiency, low stress operation Modular concept, 3 to 6 modules Easy handling, plug & play Lithium-iron-phosphate cell chemistry Cells with extra ceramic coated separator Space-saving design German Battery Management System 6 kW charge & discharge power

Power Battery

5.7

7.6

9.6

11.5

5,7 kWh 5,1 kWh 6000 180 V ... 260 V 230 V 4600 W / 4600 W 20 A / 20 A ‹5W

7,6 kWh 6,8 kWh

9,6 kWh 8,6 kWh

11,5 kWh 10,3 kWh

240 V ... 346 V 307 V 6000 W / 6000 W 20 A / 20 A

300 V ... 432 V 384 V 6000 W / 6000 W 20 A / 20 A

360 V ... 520 V 461 V 6000 W / 6000 W 20 A / 20 A

1,36x0,35x0,37 m 126 kg 5

1,61x0,35x0,37 m 150 kg 6

ELECTRICAL PARAmETERS

Nominal capacity Usable capacity (90% DoD) Cycle Life (at 80% remaining capacity) Voltage range Nominal voltage Maximum charge / discharge power Maximum charge / discharge current Standby consumption INTERFACE

Power storage interface

CAN

GENERAL

Battery technology Dimensions (height x width x depth) Weight (single module 24kg) Number of battery units IP degree of protection Type of installation Operating temperature range Connector type

LiFePO4 0,87x0,35x0,37 m 1,12x0,35x0,37 m 78 kg 102 kg 3 4 IP42 floor stand / indoor +5°C ... +40°C Weidmüller PV-Stick (MC4 compatible)

SAFETY / STANDARDS

Safety class Certificates EMC Safety

1 CE, UN 38-3, IEC 62619, IEC 62133, Safety guidelines Li-Ion-homestoragesystems BVES EN61000-6-2, EN61000-6-3, EN61000-3-2, EN61000-3-3 EN/IEC62109-1, EN/IEC62109-2

BLoCk DIAGRAm

CAN

TECHNICAL DATA PowER SToRAGE 3-phase output 2 independent MPP inputs for PV Up to 100% imbalance of MPPs Extra wide PV-voltage range High-voltage, low loss battery input Intelligent energy storage management Integrated grid management functions Easy setup via Power App solution Silent fanless cooling Power Storage

4.0

5.0

6.0

DC-INPUT

Max. recommended DC power Rated DC power MPPT Input per MPPT Maximum DC current per MPPT Rated DC voltage DC start up voltage / power DC voltage range MPP voltage range Maximum voltage DC Connector type

5000 W 6250 W 4200 W 5250 W 2 (paralleling possible) 1 12 A (24 A in parallel mode) 700 V 150 V / 25 W 140 V ... 1000 V 265 V ... 800 V 1000 V Weidmüller PV-Stick (MC4 compatible)

7500 W 6300 W

BATTERY-INPUT

DC voltage range Maximum charge / discharge current Maximum charge / discharge power Connector type

150 V ... 600 V 20 A / 20 A 6000 W / 4000 W 6000 W / 5000 W Weidmüller PV-Stick (MC4 compatible)

6000 W / 6000 W

AC-oUTPUT (GRID moDE)

Rated AC output power Maximum active power Maximum apparent power Nominal AC current per phase Maximum AC current per phase Rated frequency Frequency range Max. switch-on current Max. fault current (RMS) Rated AC voltage AC voltage range Total harmonic distortion (THD) Reactive power factor (cos phi) Anti-islanding operation Earth fault protection DC current injection Required phases, grid connections Number of feed-in phases Grid voltage monitoring Type of AC connection

4000 W 5000 W 4000 W 5000 W 6300 VA 6300 VA 5,8 A 7,3 A 9,1 A 9,1 A 50 Hz / 60 Hz 45 Hz ... 65 Hz 13 A, 0,1ms 285 mA 230V / 400 V (L1, L2, L3, N, PE) 180V ... 270V ‹ 2% at rated power 1 (adjustable range 0,8 cap….0,8 ind ) Yes RCD ‹ 0,5% In 3 (L1, L2, L3, N, PE) 3 3-phase Spring clamps

6000 W 6000 W 6300 VA 8,7 A 9,1 A

PERFoRmANCE

Stand-by consumption Maximum effi ciency ( PV – Grid ) European effi ciency ( PV – Grid) Maximum effi ciency ( PV – Battery – Grid ) Topology

‹ 4,0 W 98,16% 97,6% 97,3% Transformerless

97,7%

97,9%

OTHER

PV – DC-switch DC / AC overvoltage protection Data interface Display Cooling IP degree of protection Max. operating altitude Max. relative humidity Typical noise Operating temperature range Type of installation Dimensions (height x width x depth) Weight

Integrated Category II / Category III WIFI, optional: RS485, Multifunctional dry contact, 4 x digital in, 2 x digital in/out LCD dot matrix 128 x 64 with backlight Convection IP 42 2000 m 4 – 100% (non condensing) ‹ 35 dB -25°C … 60°C (40° at full load) Wall mounting 570 x 585 x 200 mm 26 kg

SAFETY / STANDARDS

Safety class Overload behaviour Certificates EMC Safety

1 Working point adjustment CE, DIN VDE 0126-1-1, VDE-AR-N 4105:2011-08, EN 50438 EN61000-6-2, EN61000-6-3, EN61000-3-2, EN61000-3-3 EN/IEC62109-1, EN/IEC62109-2

Block Diagram

Power Sensor

Power Switch

Easy to install High accuracy Detection of home consumption

Easy installation Retrofitting possible 3-phase power supply Secure supply during power outage

GENERAL

Maximum current Accuracy Dimensions (height x width x depth) Current sensor cable length IP degree of protection Type of installation Operating temperature range

GENERAL

3 x 50 A 1,5 % 91 x 72 x 44mm 1m IP20 DIN rail mounting / Split core +5°C ... +40°C

INTERFACE

Power Inverter Interface

Current loop

Maximum current IP degree of protection Type of installation Operating temperature range

3 x 32 A IP20 Wall mounting +5°C ... +40°C

INTERFACE

Power Inverter Interface

RS485

SYSTEm oVERVIEw

Current loop

PV-Generator 1

Power Storage

Power Switch RS485

CAN

PV-Generator 2

Power Battery

moNIToRING

Powerful RCT App Comprehensive Data visualisation System monitoring Configuration possible One click update Anytime, anyplace

Link to Google Play

Household

E-Mobility

Power Sensor

Public Grid

localy produced with 100% green power

Your local merchant:

INFORMATION & DISTRIBUTION RCT Power GmbH Line-Eid-Str. 1 78467 Konstanz Germany

© RCT Power GmbH revisions reserved Version 09/2016

Phone: +49 7531 99677 0 [email protected] www.rct-power.com