HANDBOOK FOR BATTERYLESS TELEPHONE SYSTEM 4000 (2000 GENERATION)

PHONTECH

Handbook rev. no.4 Oct.2004

Handbook page 2/43

BATTERYLESS TELEPHONE SYSTEM 4000 User Manual content Document no.

Description

Unit type

N/A N/A A-9292 99400-000-DE 99400-000-CO 99400-006-ML-01 99400-006-ML-02 99400-007-ML-01 99400-007-ML-02 99400-009-ML-01 99400-009-ML-02 99400-010-ML-01 99400-010-ML-02 99400-011-CD 99400-011-CA 00400-002-ML 00400-002-IW 96900-000-ML 96900-000-IW 00900-002-ML 96900-011-ML 88000-005-ML 88100-004-DE N/A 99400-012-EC 99400-013-EC 99400-014-EC 99400-015-EC 99400-017-EC

Handbook frontpage User Manual content DNV Type Approval Certificate System Description Commissioning procedure Single line tlph. unit, - Flush mount Single line tlph. unit, - Flush mount Single line tlph. unit, - Wall mount Single line tlph. unit, - Wall mount 12 line tlph. unit, - Flush mount 12 line tlph. unit, - Flush mount 12 line tlph. unit, - Wall mount 12 line tlph. unit, - Wall mount Relay module for tlph. units Relay module for tlph. units Headset plugbox w/call stop Headset plugbox w/call stop Relay unit Relay unit Headset w/chest switch Headset plugbox Headset w/chest switch & plug Alarm horn Rotating beacon Single line tlph. unit, External connection Single line tlph. unit, External connection 12 line tlph. unit, External connection 12 line tlph. unit, External connection BTS 4000 – Single line system External cabling BTS 4000 – 12 line system External cabling

BTS-4000 BTS-4000 BTS 4000 BTS-4000 BTS-4000 4050/4051 4050/4051 4050/4051 4050/4051 4060/4061 4060/4061 4060/4061 4060/4061 N/A N/A 4018 4018 9000 9000 9010 9011 0018 1009 R300/301 4050 4051 4060 4061 BTS-4000

1 2 3 4-17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42

1 of 1 1 of 1 1 of 3 1-14 1 of 1 Annex A Annex B Annex C Annex D Annex E Annex F Annex G Annex H Annex I Annex J Annex K Annex L Annex M Annex N Annex O Annex P Annex Q Annex R Annex S Annex T Annex U Annex V Annex W Annex X

BTS-4000

43

Annex Y

99400-018-EC

Page Page (pdf) Paper copy

Handbook page 3/43

Handbook page 4/43

PHONTECH

Doc.No.: 99400-000-DE

BATTERYLESS TELEPHONE SYSTEM 4000 SERIES 4050/4051/4055/4060/4061.

SYSTEM DESCRIPTION. LIST OF CONTENTS: 1. 2. 3. 4. 5. 6.

page

GENERAL DESCRIPTION LIST OF TELEPHONE UNITS ADDITIONAL EQUIPMENT LIST OF FACILITIES BASIC MEANS OF OPERATION INSTALLATION • • • • • • • • • • •

2 3 4 7 8 10

SYSTEM CONFIGURATION MOUNTING CABLE TERMINATION CABLE REQUIREMENTS GLANDING SCREENING FERRULING MARKING FASTENING PRESERVATION VOLUME ADJUSTMENT

7. TECHNICAL DATA 8. SINGLE LINE DIAGRAM - 12 LINE SYSTEM 9. SINGLE LINE DIAGRAM - SINGLE LINE SYSTEM

01

18.01.2002

REVISION EM -904

0

09.05.2001

FINAL DOCUMENTATION

TLY

TBA

TLY

REASON FOR ISSUE

PREPARED

CHECKED

APPROVED

REV No:

ISSUE DATE

TBA

TITLE: BATTERYLESS TELEPHONE SYSTEM

RS

TBA

12 13 14

This document is the property of PHONTECH and must not be copied or shown to a third person without our written acceptance. In the interest of product improvement, PHONTECH reserves the right to alter specification and design without notice.

SIZE: A4

DESCRIPTION

UED no: M002

DOC no: 99400-000-DE FILE NAME:

99400-000-DE

V:\prosjekt\SERIE\4\4050-51-56-57-60-61 fellesdokumenter\desc\99400-000-DE.doc Page 1 of 14

Handbook page 5/43

PHONTECH

Doc.No.: 99400-000-DE

1. GENERAL DESCRIPTION The batteryless telephone system is developed and manufactured at phonTECH A/S. The different modules in the system are designed to meet the need and demand for nonpowered internal communication on ships. Basically the system is divided into two types, the single line system (4050/4051) for end-to end communication between two stations, like the bridge and the machinery spaces. The second type is the 12 lines system, (4060/4061) for up to 12 stations. The 4055 type is a weatherproof telephone for rougher environments. Equipped with weatherproof handset. The compact design provides good installation possibilities, with a minimum space requirement. The flush mounting units are adapted to the DIN 144x144 standard for easy mounting in the bridge and engine control consoles. The modules may also be wall mounted; this requires a wall mounting back-box. (Optional) The different units are prepared for gland mounting, i.e. holes have been fitted for a wide range of cable glands. Several additional types of equipment may be connected to the Batteryless Telephone System, like headset connector boxes, extra headsets, power supplies, external signal devices relay switch boxes, etc.

.

Page 2 of 14

Handbook page 6/43

PHONTECH

Doc.No.: 99400-000-DE

2. LIST OF TELEPHONE UNITS Type BTS 4061. Type BTS 4060 Type BTS 4051 Type BTS 4050 Type BTS 4055

EXAMPLE:

12 lines amplified battery’s telephone. 12 lines battery’s telephone. Single line amplified battery’s telephone. Single line battery’s telephone. 12 lines WP (weatherproof) telephone. Bulkhead mounting.

BTS 4060 - 12 lines battery’s telephone. PHONTECH

.

Page 3 of 14

Handbook page 7/43

PHONTECH

Doc.No.: 99400-000-DE

3. ADDITIONAL EQUIPMENT. Type 4018 Type 9000 Type 0018 Type 9010 Type 99400-011 Type 4052 Type 4053

Headset Plug-box with Call stop. External signal device relay switchbox. Headset with chest switch and plug. Headset with chest switch. Relay plug-in module for external signal device. Junction box type I (12 ext.) Junction box type II (8 ext.)

4018

H E A D S E T

CALL STOP

9000

.

Page 4 of 14

Handbook page 8/43

PHONTECH

Doc.No.: 99400-000-DE

.

Page 5 of 14

Handbook page 9/43

PHONTECH

Doc.No.: 99400-000-DE

RELAY MODULE (PCB 99400-011) A relay module for activation of external signal device can be installed in the following units: - 4050 / 4051 / 4055 / 4060 / 4061

The relay module is to be mounted by the installer. The unit is delivered separately, and is to be plugged into the appropriate telephone unit. • • • • •

.

Open the backbox on the telephone unit. Plug the relay unit into the receptacle on the PCB inside the telephone. Make sure the connector pins make contact. Snap the stand off`s (2pcs) into the holes in the PCB. Make the connections according to the installation drawings 99400-017-EC or 99400-018EC. If DC voltage is used, make sure the polarity is correct. (Indication on the dwgs. 99400017-EC and 99400-018-EC)

Page 6 of 14

Handbook page 10/43

PHONTECH

Doc.No.: 99400-000-DE

4. LIST OF FACILITIES. • • • • -

.

12 LINES BATTERYLESS TELEPHONE WITH AMPLIFIER 4061. Handset with PTT button. Noise cancelling microphone. Piezo - electric buzzer for call indication. Call led. 20 seconds call delay timer. (24 VDC required) Call stop button. Call line rotary selector switch. Back lightning of the line selector and the call stop button. (24 VDC required) Extreme low current drain speech amplifier. 12 LINES BATTERYLESS TELEPHONE 4060. Handset with PTT button. Noise cancelling microphone. Piezo- electric buzzer for call indication. Call led. 20 seconds call delay timer. (24 VDC required) Call stop button. Call line rotary selector switch. Back lightning of the line selector and the call stop button. (24 VDC required)

SINGLE LINE BATTERYLESS TELEPHONE WITH AMPLIFIER 4051. Handset with PTT button. Noise cancelling microphone. Piezo- electric buzzer for call indication. Call led. 20 seconds call delay timer. (24 VDC required) Call stop button. Back lightning of the call stop button. (24 VDC required) Extreme low current drain speech amplifier. SINGLE LINE BATTERYLESS TELEPHONE 4050. Handset with PTT button. Noise cancelling microphone. Piezo- electric buzzer for call indication. Call led. 20 seconds call delay timer. (24 VDC required) Call stop button. Back lightning of the call stop button. (24 VDC required)

Page 7 of 14

Handbook page 11/43

PHONTECH

Doc.No.: 99400-000-DE

5. BASIC MEANS OF OPERATION. •

GENERAL

The batteryless telephone system is operated by means of the handset with PTT switch, the call line selector switch, (4055/4061/4060 only) and the call generator crank. There is no priority between units in the system and several users can join the system simultaneously. All users will then join the same conversation. The units are equipped with screw terminals for connection of a headset, phonTECH type 9010. The below will give a brief description of how to operate the batteryless telephone system. •

MAKE A CALL TO ANOTHER STATION (4055/4061/4060)

1. Lift the handset. See sketch on page 9 for movement. 2. Select the line by means of the line selector. 3. Crank the generator 3-5 turns. •

ANSWER A CALL FROM ANOTHER STATION. (ALL TYPES 4055/4061,4060,4051,4050)

1. Lift the handset (See sketch on page 9 for movement) and press the PTT button. Keep the button pressed at all times during conversation. 2. Optional headset: Set the PTT switch to ON and answer the call. 3. NOTE: IF EXTERNAL POWER IS CONNECTED TO THE SYSTEM, THE CALL DELAY TIMER WILL KEEP THE CALL LED ON THE TELEPHONE ILLUMINATED FOR ABOUT 20 SECONDS. TO UNLIT THE LED, PRESS THE “CALL STOP” BUTTON ON THE TELEPHONE, OR ON THE HEADSET PLUG-BOX 4018. 4. NOTE: IF EXTERNAL POWER IS CONNECTED TO THE SYSTEM, AND ANY ADDITIONAL SIGNAL DEVICE IS CONNECTED TO THE TELEPHONE, THE CALL DELAY TIMER WILL KEEP THE SIGNAL DEVICE ACTIVE FOR ABOUT 20 SECONDS. TO SILENT THE SIGNAL DEVICE, PRESS THE “CALL STOP” BUTTON ON THE TELEPHONE, OR ON THE HEADSET PLUG-BOX TYPE 4018. •

TERMINATE A CONVERSATION. (ALL TYPES 4055/4061,4060,4051,4050)

1. Replace the handset in the holder. (See sketch on page 9 for movement) 2. On optional headset set the PTT switch on the chest-switch back to normal position. •

MAKE A CALL TO ANOTHER STATION ON SINGLE LINE SYSTEM (4051/4050).

1. Lift the handset (See sketch on page 9 for movement) and press the PTT button. Keep the button pressed at all times during conversation. 2. Crank the generator 3-5 turns.

.

Page 8 of 14

Handbook page 12/43

PHONTECH

Doc.No.: 99400-000-DE •

Headset type 9010 - Operation

Make a call out from the telephone to another station: 1. Put the headset on, with the microphone close to your mouth. 2. Select line, operate the call crank on the telephone. 3. If / when the call is answered, set the talk -switch to on or temporary on. Keep the talk switch operated at all times during conversation. 4. After the conversation, set the talk-switch back to off position.

Answer a call from another station: 1. Put the headset on, with the microphone close to your mouth. 2. Set the talk -switch to on or temporary on. 3. After the conversation, set the talk-switch back to off position.

.

Page 9 of 14

Handbook page 13/43

PHONTECH

Doc.No.: 99400-000-DE

6. INSTALLATION. •

SYSTEM CONFIGURATION:

The system is to be configured by the installer. Each telephone must be connected to different “call number” with regards to the Line selector (rotary switch). This is done by means of links in each telephone. The link is to be connected between terminal 13 and the desired call number. (1-12) Consult the installation drawing 99400-017-EC and 99400-018-EC for examples. •

MOUNTING:

The telephone units (all types) are delivered for flush mounting. Optional wall mounting boxes are delivered upon request. PhonTECH highly recommends the use of junction boxes for the external cable distribution. The junction box must be located as close to the amplified telephone (4051/4061) unit as possible. On request PhonTECH will supply the junction box. Type 4052 and/or 4053. The sub-units (9000/4018/) are delivered with wall mounting box as standard. Ref. actual Data sheet for each unit and Technical specification for mounting details. •

COMPASS SAFE DISTANCE

Compass type Standard Steering Stand by steering Emergency •

Safe distance BTS-4050/4051 / 4060/4061 1,7m 0,95m

CABLE TERMINATION.

All termination according to the External Cabling diagram (example) 99400-017/18-EC. In most cases Phontech will supply a detailed custom designed “system cable diagram” for the actual delivery. •

CABLE REQUIREMENTS.

All cables used with the Batteryless Telephone System to be of approved ship cable type. ESPECIALLY IMPORTANT: o Common outer screen. o Individually twisted pairs.

.

Page 10 of 14

Handbook page 14/43

PHONTECH

Doc.No.: 99400-000-DE o Recommended conductor area is 0.75 sq.mm. o All cabling in the batteryless telephone system to be a separate network. o DO NOT COMBINE WITH OTHER CABLES. THIS IS TO PREVENT DISTURBANCE AND NOISE CAUSED BY INTERFERENCE. •

GLANDING.

The cables enter the units by means of cable glands. Where cable glands are not supplied from factory, the installer must adapt the glands to the actual cable outer diameter. This is to obtain the specified ingress protection. •

SCREENING.

The cable screen must be terminated to the ships GND in the “main unit” (4051/4061). The cable screen must be connected through the junction box(s) and terminated in terminal no 21 or earth stud in all telephones . Ref. drawings 99400-017-EC or 99400-018-EC. •

FERRULING.

The conductors to be ferruled prior to termination onto the screw terminals. •

MARKING.

Each cable to be marked with cable number. Each conductor to be marked with the specific termination number. Please note that Phontech uses plug-able screw terminals as standard. This is to make the installation and service work as smooth as possible. •

FASTENING.

Where applicable, the cables and the conductors shall be strapped to the structure. •

PRESERVATION.

Prior to, during, and after completion of the installation the equipment surfaces to be protected against acid holding fluids, pollution, moist, impacts etc. This in order to avoid damaged equipment for which Phontech will void warranty claims. •

VOLUME ADJUSTMENT

Common volume adjustment for the whole system may be adjusted inside BTS 4061 on the circuit board, R13. Adjust to “proper” audio level in the “earpiece” during a normal conversation.

.

Page 11 of 14

Handbook page 15/43

PHONTECH

Doc.No.: 99400-000-DE

7. TECHNICAL DATA. TELEPHONE UNITS 4050/4051/4060/4061 Dimensions flush mounting: 240 x 144 x 70 mm. (h x w x d) Cut- out measurement flush mounting: 212 x 116 mm. (h x w) Dimensions wall mounting wall mounting box included: 242 x 146 x 73 mm. (h x w x d) Type 4050/51/60/61: add 78 mm to depth for handset. Weight flush mounted: Weight wall mounted:

1,4 kg. 1,8 kg.

Operation voltage 24 VDC (optional) Ingress protection: IP 44. Technical data for substations etc., see data sheets for each unit.

TECHNICAL DATA. WP TELEPHONE UNIT 4055.

Dimensions flush mounting: 240 x 144 x 70 mm. (h x w x d) Cut- out measurement flush mounting: 212 x 116 mm. (h x w) Dimensions wall mounting wall mounting box included: 242 x 146 x 73 mm. (h x w x d)

Type 4055: add 115 mm to depth for handset. Weight flush mounted: Weight wall mounted:

1,4 kg. 1,8 kg.

Operation voltage 24 VDC (optional) Ingress protection: IP 44.

.

Page 12 of 14

Handbook page 16/43

PHONTECH

Doc.No.: 99400-000-DE

8. SINGEL LINE DIAGRAM – 12 LINE SYSTEM

.

Page 13 of 14

Handbook page 17/43

PHONTECH

Doc.No.: 99400-000-DE

9. SINGEL LINE DIAGRAM – SINGLE LINE SYSTEM

.

Page 14 of 14

Handbook page 18/43

PHONTECH

COMMISSIONING PROCEDURE

Use the tables below as guide during the commissioning of the batteryless telephone system. Installation (site):__________________________________ Customer/ client:__________________________________ Hull / building no:__________________________________

SCOPE OF SUPPLY Qty. Unit

Type no. Serial no. Comments

COMMISSIONING TESTS NO

ACTION

1

Check if the handbook is delivered and available for commissioning. Check the installation according to installation instructions. Ref, doc. 99400-000-DE (Twisted pairs / screening) Check call line assignment in telephones: (Link n-13) Check call signals and speech communication in the hole system. Check the additional signal devises (if installed) is operating. (20 sec. Timer)

2

3 4 5

RESPONSE (OK/FAILED)

COMMENTS

DATE DUE FOR CORRECTION

Date:___________________ Customer / clients authorized representative signature:_______________________________ Phontechs representative signature: Adresse: Bromsveien 19, N-3183 Horten Tlf.: +47 33083500 fax: 33083501 www.phontech.no fellesdokumenter\doc\99400-000-CO.doc

_______________________________ Page 1 of 1 V:\prosjekt\SERIE\4\4050-51-56-57-60-61

Handbook page 19/43

Handbook page 20/43

Handbook page 21/43

Handbook page 22/43

Handbook page 23/43

Handbook page 24/43

Handbook page 25/43

Handbook page 26/43

Handbook page 27/43

Handbook page 28/43

PHONTECH

Doc.No.: 99400-011-CA

RELAY SWITCH BOARD FOR BATTERYLESS SYSTEM 99400-001-CD DESCRIPTION

The Batteryless Telephone Board 99400-001 is designed and produced by phonTECH communication a/s, Horten in Norway. The board is a plug-in module supporting switching facility for external signal device in the batteryless telephone system. Switching capacity: 24 VDC: 115 VAC: 220 VAC:

150 VA 700 VA 1500 VA

Operation voltage: Relay coil:

24 VDC

TITLE:

PHONTECH

RELAY SWITCH BOARD FOR BATTERYLESS SYSTEM DESCRIPTION

This document is the property of DOC. NO: PHONTECH AS, and must not be copied or shown to a third party without our written acceptance.

DATE

000228

AUTH.

t.ly

In the interest of product improvement FILE: PHONTECH AS reserves the right to alter the specification and design UED No.: M002 without notice.

CHK.

tba

APPR.

tly

99400-011-CA 99400-011-CA REF:

Page 1 of 1 V:\prosjekt\SERIE\4\99400011.pcb\DESC\99400-011-CA.doc

0

REV.

-

CO.

010509

t.ly

DATE

SIGN

Handbook page 29/43

Handbook page 30/43

Handbook page 31/43

Handbook page 32/43

Handbook page 33/43

Handbook page 34/43

Handbook page 35/43

Handbook page 36/43

Doc.No.: 88100-004-DE

Material / color/ Finish Mounting Weight IP rating Operating voltage Tone frequency 1 (ST2 shorted) Tone frequency 2 (ST2 open) Sweep frequency 1 (ST3 shorted) Sweep frequency 2 (ST3 open)

0 REV No:

STRAP ST 1

STRAP ST 3

SHORTED SHORTED OPEN OPEN

SHORTED OPEN SHORTED OPEN

010927 ISSUE DATE

SPL (SOUND PRESSURE LEVEL) 110.7 dB 110.9 dB 107.7 dB 107.7 dB

FINAL DOCUMENTATION

t.ly

REASON FOR ISSUE

PREPARED

TITLE: ALARMHORN TYPE 1009 / 24 VDC DESCRIPTION. Page 1 of 1

ABS / RAL 7035 Stainless steel bracket 1.1 kg IP 56 DCV 20-28 900-1250 Hz. 670- 925 Hz 3 Hz 0.6 Hz.

CHECKED

APPROVED

SPL A- WEIGHTED. 111.3 dB 111.4 dB 107.7 dB 107.7 dB

This document is the property of PHONTECH and must not be copied or shown to a third person without our written acceptance. In the interest of product improvement, PHONTECH reserves the right to alter specification and design without notice.

SIZE: A4

UED no: NA

DOC no: 88100-004-DE FILE NAME:

88100-004-DE.doc

Handbook page 37/43

File ref.: R300 blinklys.doc The R300 and R301 is an effective heavy duty powerful revolving light in a ABS housing. It has a polygon reflector and a polycarbonate dome. The housing is equipped with a 3 mm neoprene gasket and tree M6 fixing bolts in bottom. The dome can be replaced without tools, and is available in red, amber, blue, green and clear. þ High intensity þ Weather resistant IP-65 Art.no. R301-14 R300-05 Accessories : R300 VB LE 152 LE 154

þ Different lens colours þ Reliable.

Voltage

Current consumptio n

Light bulb

Revolving speed

Weight

24 VDC

3,0 Amp.

160 RPM

0,98 kg.

230 VAC

0,2 Amp.

H1 24V/70W (Halogen) E14 / 230v / 40W

120 RPM

0,98 kg.

Wallmounting Bracket for R300 and R301 Long Life Lamp E14 Mignon 40W 240V 8.000 hours, Clear Long Life Lamp E14 Mignon 60W 240V 8.000 hours, Clear

Fixing holes 3 x ø7 ø130

250

o

M20 conduit knockout

120 (=2 x r)

ø150

Wallmounting Bracket Type R300 VB 165

Cable Entry M10

164

50

101

50 50

Fixing holes 3 x ø6,3

Phontech as • PO. Box 274 • N-3192 Horten, NORWAY Telephone +47 3308 3500 • Fax: +47 3308 3501 • E-mail: [email protected]

Handbook page 38/43

Handbook page 39/43

Handbook page 40/43

Handbook page 41/43

Handbook page 42/43

Handbook page 43/43