Next generation SCR system for fuel-efficient NOx reduction Conference Selective Catalytic Reduction 2011 26 - 28 September, 2011, Dorint Pallas Wiesbaden, Germany Dr. Tue Johannessen Amminex A/S
[email protected]
IQPC - SCR 2011
1
The environmental paradox: Low CO2 - but at the expense of NOX? • • •
NO2 is already today a major problem in many European cities Focus on low CO2 ⇒ efficient engines. Efficient diesel engines ⇒ low exhaust temperature –
(often below 200°C
⇒ Significant challenge for future legislative targets and off-cycle NOx control with AdBlue® Annual mean NO2 concentration (ug/m3) in London
Limit for 2010
IQPC - SCR 2011
2
US study on off-cycle performance with urea-SCR Pick-up truck
Avg. urban engine-out (No DEF) Urban driving – with DEF in the tank
Average urban tailpipe 0.2 g/bhp-hr
DEF = Diesel Exhaust Fluid = North America generic name for Aqueous Urea Solution
IQPC - SCR 2011
3
Ammonia-SCR: High NOx reduction potential in cold exhaust
•
NOx conversion data with NH3 provided by Haldor Topsøe A/S
1.0
Test conditions:
0.8
– – – – –
•
250 ppm NOx Conversion measured with 20 ppm NH3 slip Space velocity: 63000 hr-1. Catalyst: Fe-zeolite; aged for 50hr at 750C NO2 content: NO2/NOx= 0.3
Curve for AdBlue is based on the assumption that: –
–
AdBlue gives as high conversion as pure ammonia gas as long as injection is possible (urea hydrolysis complete) Steady-state AdBlue injection requires an exhaust temperature of 190-200°C (e.g. Dr. Rusch: “Urea SCR – Interaction of spray generation and exhaust system”, CTI Forum: SCR systems, Stuttgart, Oct. 08)
NOX conversion relative to 200 ° C
•
Urban NOx control with ammonia gas
0.6 NH3-dosing: Normalized conversion (NO2/NOx=0.3)
0.4
AdBlue (inj. at Tscr >190 °C)
0.2
Illustration of urban NOx control potential with liquid injection (AdBlue)
0.0 150
160
170
180
190
200
SCR catalyst temperature (°°C) IQPC - SCR 2011
4
AdAmmineTM: Safe storage enables ammonia for mobile applications Ammonia is very useful in many applications – incl. mobile and portable •
Storage of ammonia as pressurized liquid is inherently dangerous :
•
AdAmmineTM: Safe storage in compacted solid provides the safety essentially without loss of volumetric capacity:
AdAmmine: Usable capacity: ∼ 450g NH3 per liter AdAmmine Ammonia release: Controlled thermal desorption Sr(NH3)XCl2 ↔ Sr(NH3)X-1Cl2 + NH3 IQPC - SCR 2011
5
How safe is it? •
Ammonia stored in an AdAmmine cartridge is about four orders of magnitude less ‘accessible’ than pressurized anhydrous ammonia.
•
Even with a broken automotive cartridge/connector, passive release is very slow
•
–
About 300 days before 1.65kg has diffused out of the broken cartridge at ambient conditions
–
3.6 liter cartridge for LD/automotive:
Fire test shows no risk of cartridge bursting. –
Plastic connector melts and causes controlled venting of ammonia. Vented ammonia is oxidized in the flames.
IQPC - SCR 2011
6
Amminex ASDS technology: Ammonia Storage and Delivery Systems •
Amminex is working jointly with OEMs primarily on two system variants
•
ASDS-1: Electrical system for small/medium cars – – –
•
Two smaller main cartridges pr. system 3.5-4.5 liter cartridges Control strategy for low fuel economy impact
ASDS-2: Engine coolant system for MD/HD – –
Main cartridge(s) is approx. 11 liters Modular system concept (1-3 cartridges)
Key features: • Start-up unit: Rapid dosing after cold start • Main unit(s): System capacity • AFM: Dosing manifold • SW: Control of NH3-release on-demand IQPC - SCR 2011
7
ASDS-2: Example of system for MD/HD •
Two-tank system – –
•
∼ 11 liter cartridge (∼24 liter AdBlue) 4.5kg NH3 per main unit
Start-up unit –
1.2 liter; 550W heater
• • • •
AFM (ammonia Flow Manifold) Heating/Mounting bracket Stand-alone ‘Box’ for easy installation ASDS-controller + Amminex SW
•
Production parts:
Ammonia dosing performance: –
Dosing turn-down ratio is at least 1/100 • •
–
Example: Min/Max: 1/100 mg NH3/s (or zero flow). Can be varied by control SW.
Accuracy is at least ±5% on actual measured value in the entire range (not ‘just’ ± 5% of max. flow).
IQPC - SCR 2011
8
Off-cycle NOx control during urban driving: Improved SCR performance without additional fuel penalty
NOx conversion / Catalyst temperature (°C) / Flow [mg/s], Temperature [°C], Speed [kmph] Speed (km/hr) / Ammonia dosing
250 SCR_avg_T [°C] NOx_conversion [%] Vehicle_speed [kmph] Ammonia_dosed [mg/s]
Required catalyst temperature for operating AdBlue: > 200-225°C 200
SCR Catalyst temperature
150
High NOx conversion possible with continuous “cold” exhaust gas using Amminex solid storage technology.
100
50
0 0
500
1000
1500
2000
2500
3000
3500
4000
4500
Time [s]
IQPC - SCR 2011
9
ASDS-1: Electrically heated system for passenger cars
IQPC - SCR 2011
10
Example of components for automotive system • • • • •
Start-up unit Main cartridge(s) Compact Ammonia Flow Manifold (AFM) Heating/mounting structure for main cartridges DCU with software
IQPC - SCR 2011
11
Key performance parameters •
Dosing of pure ammonia gas – – –
•
Time-to-dose from cold start: – –
•
Generally in the 60-180s range Depends on cold soak temperature, size and heating power
Power consumption: – –
•
Example of applied dosing ranges: [0-30], [0-50] mg NH3/s Turn-down is at least 1:100 High dosing accuracy (e.g. ± 5% on measured value)
Peak power: 250W Average power consumption: 30-70W
Main unit storage capacity: 450 g NH3 (available NH3) per liter AdAmmineTM
IQPC - SCR 2011
12
CO2-friendly control SW strategy for ASDS-1 • • •
From a vehicle integration standpoint, electrical current is simpler than coolant ‘current’ Target: Keep power low by using the STU ‘all the time’. Only use electrical power for heat main unit to transfer ammonia back into the STU (regeneration).
STU fill level
Main unit fill level
Regeneration of STU by “activation of main unit Time (Weeks) IQPC - SCR 2011
13
Automotive AFM design High accuracy and robustness Attractive component cost structure Parts from automotive suppliers Dosing specs: – –
•
Dynamic turn-down ratio: 1:100 (e.g. 0.3 to 30 mg NH3/s) Accuracy: ±5% on measured value in entire dosing range
Operating pressure: – –
Pressure: 2 bar(a) < PCartridge < 6 bar(a) Exhaust back-pressure: Accuracy is not sensitive to dynamic changes in exhaust back-pressure caused by engine load.
On-going endurance test: 75 million valve cycles reached ! 90 kg ammonia dosed Accuracy remains at of ±5% on actual value.
Error on actual dosed mass (%)
• • • •
IQPC - SCR 2011
5.0% 2.5% 0 mill
0.0% 0
10
20
43 mill
30
75 mill
-2.5% -5.0%
Dosing demand [mg NH3/s]
14
Example from automotive testing of NH3-SCR
M. Fischer. Honda R&D Europe, Emission Control Concepts, November 2010 15 IQPC - SCR 2011
High conversion – even for under-floor SCR position Source: M. Fischer. Honda R&D Europe
•
NEDC test result with 200°C SOI temperature for Urea and 120°C for Ammonia
Vehicle Speed NOx Engine Out NOx post SCR Urea NOx post SCR NH3
59% less NOx
AdBlue
80
97
NH3
60 49
40
42
20 10
300
Temperature [C]
NOx conversion [%]
100
Temperature upstream SCR Temperature downstream SCR SCR catalyst Temperature
250 200
SOI time difference between Urea and NH3 gas Start of injection Urea SCR Start of injection NH3 SCR
150 100 50
0
0
Phase 1
Phase 2
0
200
400
600
800
1000
1200
Time [s]
IQPC - SCR 2011
16
High uniformity, no risk of deposits, low pressure drop • • •
Exhaust interface is a steel tube – not an injector. No droplets – high flexibility. High uniformity index at different exhaust flow conditions is demonstrated (the actual interface designed by Honda not disclosed) Source: M. Fischer. Honda R&D Europe
IQPC - SCR 2011
17
Benefits for exhaust system design •
High uniformity with direct ammonia gas dosing
•
Flexibility in SCR configuration – – –
•
Close coupled Under-floor SCR-coated filter
Flexibility in exhaust configuration – – –
No risk of deposits Low pressure drop possible at ammonia inlet zone Significantly reduced corrosion risk (no acids intermediate of urea hydrolysis)
IQPC - SCR 2011
18
AdAmmineTM industrialization
IQPC - SCR 2011
19
Amminex manufacturing for MD/HD • • • •
Approx. 11 liter unit. Material: Aluminum 4.5kg ammonia available for onboard usage. Quick-connector –
• • • • •
Rapid exchange possible
Approx. 500W heater (12V) Approx. 1.2 liter Quick-connector (gas) Electrical connector Other designs can be developed according to application requests. IQPC - SCR 2011
20
The first AdAmmine plant: Nyborg, Denmark
Land : 45.800m2. Building: 6.424 m2 (up to 20.000 m2 allowed) Administration, lab, cantina : 850 m2 Production: 5.600 m2
IQPC - SCR 2011
21
The first 10 ton of NH3 at Nyborg
IQPC - SCR 2011
22
Applicable standards for AdAmmineTM cartridges •
AdAmmineTM is not classified as hazardous goods for on-road, sea or air transportation
•
European REACH: No outstanding issues
•
AdAmmineTM cartridges do not have to fulfill requirements of the European Pressure Directive
•
Amminex has environmental approval for the Danish AdAmmineTM plant: – –
45 ton on-site ammonia storage Warehouse: • •
•
10,000 HD cartridges 10,000 Start-up units
Amminex HQ is ISO 9001 certified. –
Production facility will be ISO and TS certified
IQPC - SCR 2011
23
AFTERMARKET CARTRIDGE SERVICING & REFILLING
IQPC - SCR 2011
24
Servicing strategy and aftermarket •
Standard production method: First-fit cartridges on new vehicles
•
Cartridge replacement: Depleted cartridge is exchanged with a full unit (e.g. at OEM service station or fleet). Rapid exchange via quick-connecting (hot-swapping possible)
•
Depleted cartridges can be: – –
•
Resaturated at a decentralized facility (however not directly at OEM dealer or Fleet) Once “exhausted”, a cartridge can be recycled completely with full utilization of raw materials.
The AdAmmineTM “aerosol can” –
For certain limited applications, the cartridge strategy may be complete recycle because the value of the “housing” is low compared to the additional efforts of quality assuring a cartridge in a resaturation scenario.
IQPC - SCR 2011
25
Aftermarket: AdAmmineTM cartridges – similarities with propane distribution Propane canister (one-time use) 0.5-1kg propane
Propane transported in bottles: hazardous goods (logistics “risk fee”) Solid AdAmmineTM cartridges: not hazardous goods
Price in retail: $2.5-3 EUR (Including VAT)
Propane bottle (refill) 11kg propane Price in retail: 11-13 EUR
IQPC - SCR 2011
26
Refilling (resaturation) •
US strategy: –
•
Done by industrial partner on a license basis
Europe –
Initially, refill can be done at Amminex facility • •
–
•
Amminex plant is an existing ammonia ‘hub’ Ex. Works with 3rd party logistics company
Refill
By industrial partner
Other regions –
To be done on a license basis.
IQPC - SCR 2011
27
Examples of AdBlue price levels Cans
AdAmmineTM logistics
No of Cans Price (£/litre) 10 x 10L = 1.60/litre 100 litres 40 x 10L = 0.85/litre 400 litres 400 x 10L = 0.77/litre 4000 litres
Delivery Total Price (£ net)
IBCs
Price (EUR/liter)
Free
£
160
100
Free
£
340
400
Free
£
3080
4000
Drums No of Drums 2 x 210L = 420 litres 12 x 210L = 2540 litres 24 x 210L = 5040 litres
Liter
Cans ∼ Cartridges Drums ∼ Pallets 1244.6 IBCs ∼ £Containers
Price Delivery Total Price (£ net) (£/litre) 0.575/litre Free £ 241.5 0.49/litre
Free
0.46/litre
Free
£
Liter
2318.4
1.92
€
1.02
€
0.92
Price (EUR/liter) 420 2540 5040
Cost level for end-users Delivery Total Price (£ net) Liter depends on usage pattern
No of IBC's Price (£/litre) 1 x IBC = 0.400/litre Free 1000 litres 5 x IBC = 0.379/litre Free 5000 litres 10 x IBC = 0.365/litre Free 10000 litres
€
€
0.69
€
0.59
€
0.55
Price (EUR/liter)
£
400 + deposit
1000
£
1895 + deposit
5000
£
3650 + deposit
10000
€
0.48
€
0.45
€
0.44
Source: http://www.adblueonline.co.uk/home.php IQPC - SCR 2011
28
Bulk ammonia: Yara’s ammonia plants in Europe. •
There is a dialogue with Yara to use the synergy between existing NH3 plants and the establishment of cartridge recharge facilities to support development of infrastructure and for AdAmmineTM aftermarket.
Porsgrunn
Sluiskil Brunsbüttel Le Havre
Tertre
Ferrara
IQPC - SCR 2011
29
Summary: A few key-numbers •
2.4: Volume saving factor relative to liquid urea tank with same ammonia quantity
•
27: Number of pending patent families
•
9: Solid benefits: – – – – – – – – –
AdAmmine™: Safe solid-state ammonia storage. Direct, on-demand ammonia dosing to the SCR catalyst. High storage capacity. High dosing accuracy. No liquid injection and no risk of deposits in the exhaust line. High NOx conversion – also during urban driving. Mechanically simple – no problems with freezing. Customer-friendly: No refilling – fast cartridge replacement. Stable NOx reductant: Very long cartridge shelf life
•
70: Current number of employees in Amminex.
•
50: Number of millions of Euro invested in Amminex A/S –
•
20 Million Euro invested by Faurecia in January 2011.
2011: Year of first AdAmmineTM plant PPAP IQPC - SCR 2011
30