M 110 Multi-jet Water Meter Traditional meter bodies, for horizontal installation, for risers

M 100 / M 110 Multi-jet Water Meter Traditional meter bodies, for horizontal installation, for risers ✘ ✘ ✘ ✘ ✘ ✘ ✘ Type MNR / MPR. Nominal flow rat...
Author: Sylvia McBride
8 downloads 2 Views 129KB Size
M 100 / M 110 Multi-jet Water Meter Traditional meter bodies, for horizontal installation, for risers

✘ ✘ ✘ ✘ ✘ ✘ ✘

Type MNR / MPR. Nominal flow rate Qn 1.5 ... 15. Wet-dial meter, with ultra-sensitive metering insert. Semi-dry-dial meter, with one-hundred-per-cent roller enclosure. Pulse transmitter, for remote read-off. Magnet pointer, for retrofittable contactor. Cold water up to 50 °C.

M 100 / M 110 Multi-jet Water Meters Technology you can trust

Semi-dry-dial meter MPR

Wet-dial meter MNR

Long-running It’s still true: the good old multi-jet water meter is our most success-ful meter. An inspired synthesis of old and new. ❏ Tried and tested: yes, indeed! ❏ International: yes, of course! ❏ Up-to-the-future: yes, depend on it! Harmonized It’s immediately noticeable: all our meters have the same head (except the Qn 15 model). This means that the meter head can be replaced with the head ring all the way through to the glass and the gasket. The metering inserts, too, are externally identical: the diameter at the register has been standardized. And we are still supplying riser meters in addition to our standard models for horizontal installation. First-class Our MNR excels in terms of exemplary accuracy over a significantly wider measuring range than specified for Class C. The suspended rotor is sensitive to even the tiniest of movements. Continuous loadings of approx. 1.4 Qn or briefly of 1.2 x Qmax are no problem. And the low pressure drop is second to none. Consummately engineered Material and design, metering accuracy and durability: in every category the MNR has what it takes and meets international standards.

MNR / MPR Versatile ✘







Wet-dial MNR Semi-dry-dial MPR

Reed contactor May be calibrated and certified ........................................................................... Pulse sequence litres/pulse Other pulse sequences 100/1 on request 1 000/1

❑ Cold water up to 30 °C. D 82 Qn 1.5 ... 3.5

Maintenance-friendly ✘

6.131.42 D 98 6.131.04

Certified Development and manufacture are subjected to systematic quality assurance procedures. As validated by certification to ISO 9001 for quality and ISO 14001 for environmental protection.

Qn 6 ... 15

❑ Installation Qn 1.5 ... 15 horizontal. Approval Class C, horizontal. ❑ Display capacity 99 999 m3. ❑ Minimum scale value 0.05 l.



✘ ✘

Standardized replaceable metering inserts. Premounted adapters for divergent meter bodies. Radically redesigned meter head. One single meter head fits all bodies from Qn 1.5 to 10.

Sturdy ✘

Advantageous Old meters may be returned, and upgraded with new MNR metering inserts: for eco-compatible economy!

MNR: Wet-dial meter with ultra-responsive metering insert for optimized sensitivity. MPR: Semi-dry-dial meter with pressure-proof enclosure. Clearly legible consumption display. MNR-KN: Special version with magnet pointer 100/1 or 1 000/1. After fitting our reed disk you will have a pulse meter. MNR-KG: Pulse-type register with cable exiting at the side. Cost-efficient read-off at an external location.



Can be briefly overloaded by 20 %. Linear curve characteristic.

Up-to-the-future ✘

Alternative ARTIST, a single meter for risers and down-pipes, and of course for horizontal metering points as well.



2

Overfulfils the EEC Guidelines and ISO 4064 for cold water. Meets the requirements of the future European Directive MID 001.

How to best handle the Multi-jet Meter

Laws and regulations Water meters must always be installed by properly trained craftspersons. The instructions below are designed to help you achieve optimum metering results. In addition, the applicable laws and regulations, as well as good engineering practice, must be strictly complied with! Operating temperature Cold water meters, approved for Tmax 30 °C, can be used in applications not involving statutory calibration requirements, for operating temperatures of up to Tmax 50 °C. But they must not be used for either warm or hot water. Transport and storage Do not drop and avoid any severe impact on the water meters. Any damage will result in inaccurate metering. In very cold weather, residues of test water may freeze inside the meters during transport. If this happens, allow the meters concerned to thaw out slowly in a frost-free room. The temperature must not exceed 50 °C. Only a frostproof room with no dust will protect your meters during storage. Also, the storage temperature should not exceed 50 °C: be careful around radiators! After a lengthy period of storage, retighten the meter heads to preclude the possibility of leaks.

Commissioning At commissioning, and after every time the pipes have been drained, always open the shutoff valves slowly, so that the meters, running dry at first, are started up gently. To preclude faulty indication and damage, never allow a water/ air mixture to flow through the meters.

Horizontal installation only

MNR, MPR

MNR-S: Riser installation

To avoid soiling of your meters, take them to the place of installation in their original packing, or at least use thread protection caps. Installation Give new or modified piping a thorough flush-out at as high a pressure as possible. Fit adapters in place of the meters. Install the water meters in a frostproof location permitting easy read-off. Make sure the direction of flow is correct, by checking the arrows on the meters themselves. The MNR is only approved for horizontal installation. The measuring points must be located so as to ensure that the meters are always completely filled with water.

During a period of frost, you should blow into the meter softly before installing it, to check whether it’s functioning properly. Make sure that all the materials used for the installation job are suitable for drinking water. We recommend using an installation clamp. It’s not essential to have a straight section of pipe upstream or downstream of the meter. Conversely, shutoff valves must be installed upstream and downstream of the meter. A drain cock is advisable. The valve downstream of the meter must under statutory regulations be fitted with an approved non-return valve. For safety’s sake, our meters can also be supplied with a non-return valve.

3

Calibration validity and maintenance Water meters used or provided in business transactions must be calibrated or certified. In conformance with the EEC Guidelines, the duration of calibration validity is 6 years for cold water meters and 5 years for warm water meters. These cycles have also proved appropriate as maintenance intervals for non-certified meters. Depending on the water quality and operating conditions involved, however, a shorter interval may be necessary. Warranty procedures If you need to make a guarantee claim on one of our water meters, please send it to us unopened and still with the lead seal unbroken, with a note specifying that the warranty is involved. Otherwise no incoming examination will be performed, and the cause of the damage concerned can no longer be reconstructed subsequently.

The standard meters

Multi-jet meter Meter size / nominal flow rate Nominal size

MNR, MPR Qn m 3/h 1.5 1.5 2.5 3.5 3.5 DN mm 15 15 20 20 25 DN inches 1/2 3/4 3/4 3/4 1 ............................................................................................................................................................................................................................................................................................................................ D1 Meter connection thread ISO 228/1 inches G 3/4 B G1B G1B G1B G 1 1/4 B D2 Connection pipe thread ISO 7/1 inches R 1/2 R 3/4 R 3/4 R 3/4 R1 ............................................................................................................................................................................................................................................................................................................................ L1 Meter length Standard mm 165 190 190 220 260 Option mm 145/170/190 165 165/220 — 175 L2 Connector length mm 40 50 50 50 60 ............................................................................................................................................................................................................................................................................................................................ B Width mm 100 100 100 100 100 ............................................................................................................................................................................................................................................................................................................................ H1 Centerline height mm 31 31 31 31 31 H2 Overall height mm 115 115 115 115 115 ............................................................................................................................................................................................................................................................................................................................ Weight kg 1.5 1.5 1.6 1.6 2.2 ............................................................................................................................................................................................................................................................................................................................ Class C Horizontal installation Maximum flow rate Qmax m3/h 3 3 5 7 7 Transitional flow rate Qt l/h 22.5 22.5 37.5 52.5 52.5 Minimum flow rate – Required Qmin l/h 15 15 25 35 35 – Actual Qmin l/h 12 12 20 20 20 ............................................................................................................................................................................................................................................................................................................................ Continuous load ca. 1.4 x Qn l/h 2 100 2 100 3 500 4 900 4 900 Temperature Tmax °C 50 50 50 50 50 Pressure rating PN 16 16 16 16 16 Flow capacity at 1 bar pressure loss m 3/h 4.4/4.7 4.4/4.7 6.7 7.2 7.2

MNR, MPR Qn 1.5 ... 15

B

H2 D1 H1

L1

L2

D2

4

Qn 1.5 2.5 3.5 6

10 15

EEC standards require head loss not to exceed 0.25 bar at Qn 1.0 bar at Qmax

1.0

Head loss in bar

0.1

0.01 0.1 0.2 0.3 0.5 Flow rate in m3/h

1

2 3 4 5

10

20 30 40 50

Multi-jet meter Meter size / nominal flow rate Nominal size

100

MNR, MPR Qn m3/h 6 6 10 15 15 DN mm 25 32 40 50 50 DN inches 1 1 1/4 1 1/2 2 2 ............................................................................................................................................................................................................................................................................................................................ D1 Meter connection thread ISO 228/1 inches G 1 1/4 B G 1 1/2 B G2B G 2 1/2 B Flange D2 Connection pipe thread ISO 7/1 inches R1 R 1 1/4 R 1 1/2 R2 — ............................................................................................................................................................................................................................................................................................................................ L1 Meter length Standard mm 260 260 300 270 270 Option mm — — — 300 300 L2 Connector length mm 60 60 70 60 — ............................................................................................................................................................................................................................................................................................................................ B Width mm 100 100 100 135 135 ............................................................................................................................................................................................................................................................................................................................ H1 Centerline height mm 43 43 46 51 83 H2 Overall height mm 130 130 153 174 189 ............................................................................................................................................................................................................................................................................................................................ Weight kg 2.5 2.5 3.7 7.5 10 ............................................................................................................................................................................................................................................................................................................................ Class C Horizontal installation Maximum flow rate Qmax m3/h 12 12 20 30 30 Transitional flow rate Qt l/h 90 90 150 225 225 Minimum flow rate – Required Qmin l/h 60 60 100 450 450 – Actual Qmin l/h 40 40 60 150 150 ............................................................................................................................................................................................................................................................................................................................ Continuous load ca. 1.4 x Qn l/h 8 400 8 400 14 000 21 000 21 000 Temperature Tmax °C 50 50 50 50 50 Pressure rating PN 16 16 16 16 16 Flow capacity at 1 bar pressure loss m3/h 12.8 12.8 22 30.5 30.5

MNR, MPR Qn 15 Flange

B

H2 132 x 132 H1

L1

5

The riser meters

Qn 1.5 2.5 3.5 6

10

EEC standards require head loss not to exceed 0.25 bar at Q n 1.0 bar at Qmax

Head loss in bar

1.0

0.1

0.01 0.1 0.2 0.3 0.5 Flow rate in m3/h

1

2 3 4 5

10

Multi-jet meter Meter size / nominal flow rate Nominal size

20 30 40 50

100

MNR-S, MPR-S Qn m 3/h 1.5 2.5 3.5 6 10 DN mm 20 20 25 25 40 DN inches 3/4 3/4 1 1 1 1/2 ............................................................................................................................................................................................................................................................................................................................ D1 Meter connection thread ISO 228/1 inches G1B G1B G 1 1/4 B G 1 1/4 B G2B D2 Connection pipe thread ISO 7/1 inches R 3/4 R 3/4 R1 R1 R 1 1/2 ............................................................................................................................................................................................................................................................................................................................ L1 Meter length mm 105 105 150 150 200 L2 Connector length mm 50 50 50 60 70 ............................................................................................................................................................................................................................................................................................................................ B1 Width mm 100 100 100 100 100 B2 Clearance Pipe axis to meter axis mm 80 80 94 94 120 ............................................................................................................................................................................................................................................................................................................................ H3 Distance mm 22 22 28 28 36 H4 Overall height mm 135 135 151 151 195 ............................................................................................................................................................................................................................................................................................................................ Weight kg 1.8 1.8 2.6 2.6 5.5 ............................................................................................................................................................................................................................................................................................................................ Class C Installation in risers Maximum flow rate Qmax m3/h 3 5 7 12 20 Transitional flow rate Qt l/h 22.5 37.5 52.5 90 150 Minimum flow rate – Required Qmin l/h 15 25 35 60 100 – Actual Qmin l/h 15 20 20 40 120 ............................................................................................................................................................................................................................................................................................................................ Continuous load ca. 1.4 x Qn l/h 2 100 3 500 4 900 8 400 14 000 Temperature Tmax °C 50 50 50 50 50 Pressure rating PN 16 16 16 16 16 Flow capacity at 1 bar pressure loss m 3/h 4 6.7 6.7 12 24

Wet-dial MNR-S Semi-dry-dial MPR-S ❑

MNR-S, MPR-S Qn 1.5 ... 10

Cold water up to 30 °C. Qn 1.5 ... 3.5 D 82

D2

6.131.42 D 98 6.131.04



❑ ❑

Qn 6 ... 10

Installation in risers. Approval Class C. Display capacity 99 999 m3. minimum scale value 0.05 l.

B1 D1

L2

L1

H4

H3

B2

6

The order numbers

MNR, MNR-S Wet-dial register. Class B certification. Body epoxy resin-coated.

Replacement meter Class B certification. Body painted.

MPR, MPR-S Semi-dry-dial register. Class B certification. Body epoxy resin-coated.

Replacement meter Class B certification. Body painted.

Flow Nominal Meter MNR MNR MPR MPR rate size length Replacement Replacement Qn meter meter m3/h inches mm Order No. Order No. Order No. Order No. ........................................................................................................................................................................................................................................... 1.5 1/2 145 R R R R 1.5 1/2 165 0524905 1198536 1135704 1198781 1.5 1/2 170 R R R R 1.5 1/2 190 R R R R 1.5 3/4 165 R R R R 1.5 3/4 190 1198307 1198552 1143243 1171344 ........................................................................................................................................................................................................................................... 2.5 3/4 165 R R R R 2.5 3/4 190 0186675 0184996 1135712 1149489 2.5 3/4 220 0501407 1156906 1156779 1198803 ........................................................................................................................................................................................................................................... 3.5 3/4 220 R R R R 3.5 1 175 R R R R 3.5 1 260 1198323 1198579 1198730 1198811 ........................................................................................................................................................................................................................................... 6 1 260 1171093 1198587 1198749 1198838 6 1 1/4 260 1171107 1198595 1198757 1198846 ........................................................................................................................................................................................................................................... 10 1 1/2 300 1171115 1198609 1198765 1198854 ........................................................................................................................................................................................................................................... 15 2 270 0636037 0695122 0647152 0695149 15 Flange 270 0636053 0695130 0647179 0695157 15 2 300 0636045 R 0647160 R 15 Flange 300 0636061 R 0647187 R Flange: 132 x 132 mm

R: on request

Flow Nominal Meter MNR-S MNR-S MPR-S MPR-S rate size length Replacement Replacement Qn -S -S meter meter m3/h inches mm Order No. Order No. Order No. Order No. .......................................................................................................................................................................................................................................... 1.5 3/4 105 1185027 1185035 1185183 1185175 .......................................................................................................................................................................................................................................... 2.5 3/4 105 0501533 0185538 1173355 1185191 ........................................................................................................................................................................................................................................... 3.5 1 150 1185213 1185221 1185256 1185264 ........................................................................................................................................................................................................................................... 6 1 150 0630977 1185108 1185329 1185337 ........................................................................................................................................................................................................................................... 10 1 1/2 200 0630993 0642487 0642479 1185345

Accessories

Description

Nominal size 1 pair inches Order No. ....................................................................................................................................... Connector 1/2 0501184 1 pair 3/4 0501124 1 0501147 1 1/4 0501206 1 1/2 0501161 2 0501101

7

MNR-KN

The order numbers for standard pulse sequences

MNR-KN, MNR-S-KN Magnet pointer 100/1, 1 000/1. Retrofit reed disk at any point in time. Class B certification. Body epoxy resin-coated.

Replacement meter On request. Class B certification. Body painted.

MNR-KG, MNR-S-KG Pulse-type register 100/1, 1 000/1. Other pulse sequences on request. Complete with pulse transmitter. Class A certification. Body epoxy resin-coated.

Reed contactor Contact load 24 V, 100 mA with suitable spark suppression, protection rating IP 67.

Flow rate Nominal Meter MNR-KN litres/pulse MNR-KG litres/pulse Qn size length 100/1 1 000/1 100/1 1 000/1 3 m /h inches mm Order No. Order No. Order No. Order No. ........................................................................................................................................................................................................................................... 1.5 1/2 145 R R R R 1.5 1/2 165 0646334 0637661 1185124 1185132 1.5 1/2 170 R R R R 1.5 1/2 190 R R R R 1.5 3/4 165 R R R R 1.5 3/4 190 R R R R ........................................................................................................................................................................................................................................... 2.5 3/4 165 R R R R 2.5 3/4 190 0646342 0637653 0562521 0562603 2.5 3/4 220 R R R R ........................................................................................................................................................................................................................................... 3.5 3/4 190 R R R 1185159 3.5 3/4 220 R R R R 3.5 1 175 R R R R 3.5 1 260 0649570 0649597 1185140 R ........................................................................................................................................................................................................................................... 6 1 260 0646369 0641944 0694142 0694150 6 1 1/4 260 0646350 0641928 0694169 0694177 ........................................................................................................................................................................................................................................... 10 1 1/2 300 0646377 0641952 0694185 0694193 ........................................................................................................................................................................................................................................... 15 2 270 0679917 0680036 0694223 0694231 15 Flange 270 0679933 0680052 0694207 0694215 15 2 300 R R R R 15 Flange 300 R R R R Flange: 120 x 120

R: on request

Flow rate Nominal size Meter length MNR-S-KN litres/pulse MNR-S-KG litres/pulse Qn -S -S 100/1 1 000/1 100/1 1 000/1 3 m /h inches mm Order No. Order No. Order No. Order No. ........................................................................................................................................................................................................................................... 1.5 3/4 105 0647500 0647713 R R ........................................................................................................................................................................................................................................... 2.5 3/4 105 0647519 0647721 1185086 0574345 ........................................................................................................................................................................................................................................... 3.5 1 150 0649678 0649686 R R ........................................................................................................................................................................................................................................... 6 1 150 0647527 0647748 R 0642517 ........................................................................................................................................................................................................................................... 10 1 1/2 200 0647543 0647764 0642525 0642533 R: on request

Accessories

Description Order No. ............................................................................................................................................................................................................................................ Reed disk, complete MNR-KN / MPR-KN 100 litres / 1 pulse 0645737 Cable length 1 m 1 000 litres / 1 pulse 0645745 ............................................................................................................................................................................................................................................ Reed pulse transmitter MNR-KG as spare part 0507062 Cable length 1 m

ELSTER Messtechnik GmbH Otto-Hahn-Strasse 25 D-68623 Lampertheim Phone +49 (0) 62 06 / 9 33-0 Telefax +49 (0) 62 06 / 9 33-100 [email protected] www.elstermesstechnik.com

L 01.12 e / 06.04 Changes may occur without notice