IRIS system – the panel Technical parameters
Up to 4 loops, 96 zones Up to 32 panels in a Network (TCP/IP protocol) Touch screen display System Sensor protocol - 198 devices per loop (99 detectors/ 99 modules). Teletek Electronics protocol – 250 devices per loop. Each loop comes with build in 2 isolators Each device has 40 symbols name. Day/Night mode Up to 128 programmable inputs/outputs – free programmable. Ethernet Interface for programming and monitoring USB Interface for firmware update Multilanguage support 10 000 events log New - Self addressing Power supply – 12V/4A Only 1 battery 12V/18Ah
Certificate EN54-2/4
SIMPO - Addressable Fire Alarm Panel
SIMPO
1 build in loop
Total loops capabilities - 2
16 Zone Led indicators
250 Devices per Loop – total of 500
Thermal Printer
Bus Network for multiple panel work
Extinguishing Expander
LCD display with 4 rows of 40 characters Easy to read and navigate screen and menu
IRIS
SIMPO
1-4
1-2
250/2km
250/2km
1000
500
500mA
500mA
20 per loop
20 per loop
250/1km
250/1km
Redundant processor
Yes
-
Zones
96
16
4 (EN54), 4 programmable
4 (EN54), 4 programmable
Yes
in development
in development
in development
32
32
Printer
External
External
Battery
1*12V/18Ah
1*12V/18Ah
Switching (100W)
Switching (65W)
Graphical (320/240) & touch screen
4*40 characters
10 000
10 000
Addressing with programmer
Yes
Yes
Self addressing
Yes
Yes
Auto addressing
in development
in development
Observer support
Yes
in development
Loops Devices per Loop Devices per System Maximum loop current Maximum loop sounders Maximum isolated devices
Outputs LAN Network Redundant Network Panels in network
Power Supply Display Event Log
Thermal Detector - SensoIRIS T110 Basic info
Type and sensitivity chosen from the panel (А2S,BS,A1R,) Default setting A2S – Fixed Temperature Day/Night sensitivity LED indication Optional build in isolator - SensoIRIS T110 IS. Addressing by means of hand-held programmer or the panel Comply EN54 – 5
Smoke Detector - SensoIRIS S130 Basic info
Sensitivity chosen from the panel Auto compensation Day/Night sensitivity Pre alarm LED indication Signal : Clean me now! Optional build in isolator - SensoIRIS S130 IS. Addressing by means of hand-held programmer or the panel Comply EN54 – 7
Multi criteria Detector - SensoIRIS M140
Basic info
Smoke and Thermal Detector Auto compensation of the smoke part Type and sensitivity chosen from the panel Day/Night sensitivity LED indication Optional build in isolator - SensoIRIS M140 IS. Addressing by means of hand-held programmer or the panel Comply EN54 - 5/7
Call Point - SensoIRIS MCP150 Technical data
Resettable element Standby LED indication Test by means of a special test key Optional: Transparent protective hinge cover Addressing by means of hand-held programmer or by the panel Comply EN54 - 11
SensoIRIS Modules Available modules
Module Isolator MIO – Module 2 Inputs/2 Outputs with Build-In Isolator MOUT – Module 1 Supervised Output with Build-In Isolator MINP – Module 1 mini Input MC-Z – Conventional Zone Module with Build-In Isolator MC-D – Conventional Detector Module (B24A) Addressing by means of hand-held programmer Comply EN54 - 18
SensoIRIS Modules Applications Module Isolator
For limit short circuits in the loop. Addressing by means of hand-held programmer or the panel When a short circuit occurs between two modules or between module and the build in Loop Isolator (Each loop card has 2 build-in isolators), all devices between will be shut down until the short is removed. According to EN-54-14 and Teletek Electronics recommends you each 32nd device to be an isolator module, or device with isolator
Senso IRIS IO Modules
SensoIRIS MIO 22 (two supervised inputs, two outputs, build-in isolator) SensoIRIS MIO 40 (four supervised inputs, build-in isolator) NEW !!! SensoIRIS MIO 04 (four outputs, build-in isolator) NEW !!! SensoIRIS MOUT (one supervised 24V potential output, externally powered, build-in isolator) SensoIRIS MOUT 240(mains switch output, build-in isolator) NEW !!! SensoIRIS MC-Z (module conventional zone, externally powered, build-in isolator) SensoIRIS MINP (mini input module)
SensoIRIS Modules Applications Module MIO – 0/2/4 inputs и 4/2/0 outputs
Useful for system automation The inputs are frequently used for receiving a signal from devices which are external for the system. For Devices like: Fire Extinguishing Panel Relays, Water Valve Relays, etc The outputs are relay contacts. For devices like: shutting down power panels, NON Stop Elevators, Ventilation, etc
Addressing by means of hand-held programmer or the panel
SensoIRIS Modules Applications Module MOUT – 1 Potential output
It is used mostly for conventional sounders. The power supply has to be from an external source.
Addressing by means of hand-held programmer
SensoIRIS Modules Applications Module MCZ – Conventional Zone Monitor
For conventional fire detectors.
Addressing by means of hand-held programmer The power supply can be provided either from the loop card or from an external power supply.
If it is from the loop card – output L+ has to be used (it limits the current up to 20 mA) If it is from an external power supply – output H+ has to be used (it limits the current up to 50 mA).
SensoIRIS Modules Applications Module MINP – 1 input
For receiving signals from an external devices (Dry contact), or for connecting devices with different purpose then fire alarm. Addressing by means of hand-held programmer or the panel
Example: Gas detector(conventional) The panel supports a custom message (up to 40 symbols)for this module, different then FIRE - The panel supports up to 128 such modules per system with different message for each one.
Programming device
Programming device for SensoIRIS detectors and modules Designed for reading and writing addresses to the devices
SensoIRIS strobes and sounders Basic info
2 sound levels (92 dB/100dB) – chosen from the panel 32 sound types – chosen from the panel Powered by loop Addressing by means of hand-held programmer or the panel Comply EN54 – 3
Models: Base Build sounder/strobes with optional build in isolator Wall mounting sounder-strobes with optional build in isolator Wall mounting sounders with optional build in isolator
Monitoring Software Alvis and Teletek Observer
New Software Development: • Better price • Lighter Interface • Easier Installation • More User Friendly
• A general-purpose tool to develop user specific monitoring and control system; • Suitable for monitoring and control of small and large protected areas; • No limitation of sort, quantity, producer the way of connection of devices; • Based on client-server architecture, allowing distributed division of the alarm and monitored system among several computers interconnected in a network; • The monitored panels can be connected to different computers and their operation can be controlled by another computer.
Software
Observer Monitoring Software
2013
Observer – technical parameters 23
Monitoring of up to 32 Fire panels Up to 32 000 devices ProsTE files support JPG files support Main Plan picture Each Zone picture support Multilanguage support Up to 10 000 Event log SensoIRIS devices support Remote panels control Administrator and Regular users Real time monitoring
Observer – Special Features and Advantages 24
Direct Proste files import (Device name, zone name, panel name and panel IP address) Devices Drag and drop placement Panels control Minimum programming Simple and User Friendly Interface Windows XP and Windows 7 support Multilanguage support Protection by means of password and hardware key (Dongle) Event audio signalization
Observer – Direct ProsTE files import Read
panels with ProsTE Set names for detectors and zones Save the settings to TDF file Read the file with Observer Just place the detectors over the Plan
25
Observer – Devices Drag and drop placement 26
Select
desired detector Drag and drop it over the plan Resize it to the dimensions needed
Observer – Each zone picture support 27
Load main plan picture Load individual plan for each zone Picture pop up in case of event
Observer – Password and hardware key protection 28
Administrator
password User password Hardware key dongle
Observer – Log file print function
Log file can be printed in specially designed view
29
Observer – Remote panel’s control 30
Evacuate Reset Silence
Alarm Silence Buzzer
Observer – Multilanguage support 31
Language
strings are easy for translation Language is easy for selection
Observer – Real Time Monitoring
User friendly interface Audio signalization in case of event Events dialog Devices dialog Panels dialog Log dialog
32