IRIS system the panel

IRIS system – the panel Technical parameters                  Up to 4 loops, 96 zones Up to 32 panels in a Network (TCP/IP protocol...
Author: Bruno Flowers
29 downloads 1 Views 3MB Size
IRIS system – the panel Technical parameters                 

Up to 4 loops, 96 zones Up to 32 panels in a Network (TCP/IP protocol) Touch screen display System Sensor protocol - 198 devices per loop (99 detectors/ 99 modules). Teletek Electronics protocol – 250 devices per loop. Each loop comes with build in 2 isolators Each device has 40 symbols name. Day/Night mode Up to 128 programmable inputs/outputs – free programmable. Ethernet Interface for programming and monitoring USB Interface for firmware update Multilanguage support 10 000 events log New - Self addressing Power supply – 12V/4A Only 1 battery 12V/18Ah

Certificate EN54-2/4

SIMPO - Addressable Fire Alarm Panel

SIMPO 

1 build in loop



Total loops capabilities - 2



16 Zone Led indicators



250 Devices per Loop – total of 500



Thermal Printer



Bus Network for multiple panel work



Extinguishing Expander

LCD display with 4 rows of 40 characters Easy to read and navigate screen and menu

IRIS

SIMPO

1-4

1-2

250/2km

250/2km

1000

500

500mA

500mA

20 per loop

20 per loop

250/1km

250/1km

Redundant processor

Yes

-

Zones

96

16

4 (EN54), 4 programmable

4 (EN54), 4 programmable

Yes

in development

in development

in development

32

32

Printer

External

External

Battery

1*12V/18Ah

1*12V/18Ah

Switching (100W)

Switching (65W)

Graphical (320/240) & touch screen

4*40 characters

10 000

10 000

Addressing with programmer

Yes

Yes

Self addressing

Yes

Yes

Auto addressing

in development

in development

Observer support

Yes

in development

Loops Devices per Loop Devices per System Maximum loop current Maximum loop sounders Maximum isolated devices

Outputs LAN Network Redundant Network Panels in network

Power Supply Display Event Log

Thermal Detector - SensoIRIS T110 Basic info

      

Type and sensitivity chosen from the panel (А2S,BS,A1R,) Default setting A2S – Fixed Temperature Day/Night sensitivity LED indication Optional build in isolator - SensoIRIS T110 IS. Addressing by means of hand-held programmer or the panel Comply EN54 – 5

Smoke Detector - SensoIRIS S130 Basic info

        

Sensitivity chosen from the panel Auto compensation Day/Night sensitivity Pre alarm LED indication Signal : Clean me now! Optional build in isolator - SensoIRIS S130 IS. Addressing by means of hand-held programmer or the panel Comply EN54 – 7

Multi criteria Detector - SensoIRIS M140

Basic info

       

Smoke and Thermal Detector Auto compensation of the smoke part Type and sensitivity chosen from the panel Day/Night sensitivity LED indication Optional build in isolator - SensoIRIS M140 IS. Addressing by means of hand-held programmer or the panel Comply EN54 - 5/7

Call Point - SensoIRIS MCP150 Technical data

     

Resettable element Standby LED indication Test by means of a special test key Optional: Transparent protective hinge cover Addressing by means of hand-held programmer or by the panel Comply EN54 - 11

SensoIRIS Modules Available modules

       

Module Isolator MIO – Module 2 Inputs/2 Outputs with Build-In Isolator MOUT – Module 1 Supervised Output with Build-In Isolator MINP – Module 1 mini Input MC-Z – Conventional Zone Module with Build-In Isolator MC-D – Conventional Detector Module (B24A) Addressing by means of hand-held programmer Comply EN54 - 18

SensoIRIS Modules Applications Module Isolator   



For limit short circuits in the loop. Addressing by means of hand-held programmer or the panel When a short circuit occurs between two modules or between module and the build in Loop Isolator (Each loop card has 2 build-in isolators), all devices between will be shut down until the short is removed. According to EN-54-14 and Teletek Electronics recommends you each 32nd device to be an isolator module, or device with isolator

Senso IRIS IO Modules       

SensoIRIS MIO 22 (two supervised inputs, two outputs, build-in isolator) SensoIRIS MIO 40 (four supervised inputs, build-in isolator) NEW !!! SensoIRIS MIO 04 (four outputs, build-in isolator) NEW !!! SensoIRIS MOUT (one supervised 24V potential output, externally powered, build-in isolator) SensoIRIS MOUT 240(mains switch output, build-in isolator) NEW !!! SensoIRIS MC-Z (module conventional zone, externally powered, build-in isolator) SensoIRIS MINP (mini input module)

SensoIRIS Modules Applications Module MIO – 0/2/4 inputs и 4/2/0 outputs  

  



Useful for system automation The inputs are frequently used for receiving a signal from devices which are external for the system. For Devices like: Fire Extinguishing Panel Relays, Water Valve Relays, etc The outputs are relay contacts. For devices like: shutting down power panels, NON Stop Elevators, Ventilation, etc

Addressing by means of hand-held programmer or the panel

SensoIRIS Modules Applications Module MOUT – 1 Potential output  



It is used mostly for conventional sounders. The power supply has to be from an external source.

Addressing by means of hand-held programmer

SensoIRIS Modules Applications Module MCZ – Conventional Zone Monitor 

 

For conventional fire detectors.

Addressing by means of hand-held programmer The power supply can be provided either from the loop card or from an external power supply.  

If it is from the loop card – output L+ has to be used (it limits the current up to 20 mA) If it is from an external power supply – output H+ has to be used (it limits the current up to 50 mA).

SensoIRIS Modules Applications Module MINP – 1 input





For receiving signals from an external devices (Dry contact), or for connecting devices with different purpose then fire alarm. Addressing by means of hand-held programmer or the panel

Example: Gas detector(conventional) The panel supports a custom message (up to 40 symbols)for this module, different then FIRE - The panel supports up to 128 such modules per system with different message for each one.

Programming device

 Programming device for SensoIRIS detectors and modules  Designed for reading and writing addresses to the devices

SensoIRIS strobes and sounders Basic info 

  



   

2 sound levels (92 dB/100dB) – chosen from the panel 32 sound types – chosen from the panel Powered by loop Addressing by means of hand-held programmer or the panel Comply EN54 – 3

Models: Base Build sounder/strobes with optional build in isolator Wall mounting sounder-strobes with optional build in isolator Wall mounting sounders with optional build in isolator

Monitoring Software Alvis and Teletek Observer

New Software Development: • Better price • Lighter Interface • Easier Installation • More User Friendly

• A general-purpose tool to develop user specific monitoring and control system; • Suitable for monitoring and control of small and large protected areas; • No limitation of sort, quantity, producer the way of connection of devices; • Based on client-server architecture, allowing distributed division of the alarm and monitored system among several computers interconnected in a network; • The monitored panels can be connected to different computers and their operation can be controlled by another computer.

Software

Observer Monitoring Software

2013

Observer – technical parameters 23

           

Monitoring of up to 32 Fire panels Up to 32 000 devices ProsTE files support JPG files support Main Plan picture Each Zone picture support Multilanguage support Up to 10 000 Event log SensoIRIS devices support Remote panels control Administrator and Regular users Real time monitoring

Observer – Special Features and Advantages 24



      



Direct Proste files import (Device name, zone name, panel name and panel IP address) Devices Drag and drop placement Panels control Minimum programming Simple and User Friendly Interface Windows XP and Windows 7 support Multilanguage support Protection by means of password and hardware key (Dongle) Event audio signalization

Observer – Direct ProsTE files import  Read

panels with ProsTE  Set names for detectors and zones  Save the settings to TDF file  Read the file with Observer  Just place the detectors over the Plan

25

Observer – Devices Drag and drop placement 26

 Select

desired detector  Drag and drop it over the plan  Resize it to the dimensions needed

Observer – Each zone picture support 27   

Load main plan picture Load individual plan for each zone Picture pop up in case of event

Observer – Password and hardware key protection 28

 Administrator

password  User password  Hardware key dongle

Observer – Log file print function 

Log file can be printed in specially designed view

29

Observer – Remote panel’s control 30

 Evacuate  Reset  Silence

Alarm  Silence Buzzer

Observer – Multilanguage support 31

 Language

strings are easy for translation  Language is easy for selection

Observer – Real Time Monitoring  

   

User friendly interface Audio signalization in case of event Events dialog Devices dialog Panels dialog Log dialog

32