Installation Modular Industrial ETHERNET Backbone Switch MACH 4000 Familie M4-FAST 8SFP. M4-FAST 8TP-RJ45-PoE FAULT RL1 RL2

Anwender-Handbuch Installation Modular Industrial ETHERNET Backbone Switch MACH 4000 Familie LS/DA M4-FAST 8SFP 1 2 3 4 5 6 7 8 MEDIA SLOTS...
Author: Hajo Frei
4 downloads 2 Views 4MB Size
Anwender-Handbuch Installation Modular Industrial ETHERNET Backbone Switch MACH 4000 Familie

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

MEDIA SLOTS 3 1

4 2 SLOT.PORT

P

P1

P2

P3

P4

RM

RL1

RL2

FAN

RUN

L/D

FDX

1000

AN

TP/FO

2

1

7

5

8

3

6

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

1

P

M4-FAST 8TP-RJ45-PoE

4

7

2

5

8

3

6

P

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

P

MACH 4002 48+4G RING LED PORT STBY TEST

4

2

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-8TP-RJ45

LED

1

LS/DA 6.1

LED

RL1

6.16 LS/DA

V.24

FAULT

M4-AIR

USB

SELECT RL2 LS

DA

LS

5.1

DA

LS

5.2

DA

LS

5.3

DA

6.1 6.2

5.4

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

MACH 4002-48+4G LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

MEDIA SLOTS 3 1

4 2 SLOT.PORT

P2

P3

RM

RL1

RL2

FAN

RUN

L/D

P

FDX

P1

1000

AN

TP/FO

2

1

7

5

8

3

6

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

1

P

M4-FAST 8TP-RJ45-PoE

P4

4

7

2

5

8

3

6

P

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

P

MACH 4002 48+4G RING LED PORT STBY TEST

4

2

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-8TP-RJ45

LED

1

LS/DA 6.1

LED

RL1

V.24

FAULT

M4-AIR

USB

SELECT RL2

6.1

6.2

6.4

6.3

6.5

6.6

6.7

6.8

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

MACH 4002-24G LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

MEDIA SLOTS 3 1

4 2 SLOT.PORT

P2

P3

RM

RL1

RL2

FAN

RUN

L/D

P

FDX

P1

1000

AN

TP/FO

2

1

7

5

8

3

6

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

P

M4-FAST 8TP-RJ45-PoE

P4

1

4

7

2

5

8

3

6

P

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

P

MACH 4002 48+4G RING LED PORT STBY TEST

4

2

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-8TP-RJ45

LED

1

LS/DA 6.1

LED

RL1

6.16 LS/DA

V.24

FAULT

M4-AIR

USB

SELECT RL2

6.1

6.2

6.4

6.3

6.5

6.6

6.7

6.8

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

MACH 4002-48G LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

MEDIA SLOTS 3 1

4 2 SLOT.PORT

P2

P3

RM

RL1

RL2

FAN

RUN

L/D

P

FDX

P1

1000

AN

TP/FO

2

1

7

5

8

3

6

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

1

P

M4-FAST 8TP-RJ45-PoE

P4

4

7

2

5

8

3

6

P

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

P

MACH 4002 48+4G LED RING PORT STBY TEST

4

2

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-8TP-RJ45

LED

1

LS/DA 6.1

LED

RL1

V.24

FAULT

M4-AIR

USB

SELECT RL2

5.1

5.2

6.1 6.2

5.3

6.3 6.4

6.5 6.6

6.7 6.8

MACH 4002-24G+3X LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

MEDIA SLOTS 3 1

4 2 SLOT.PORT

P2

P3

RM

RL1

RL2

FAN

RUN

L/D

P

FDX

P1

1000

AN

TP/FO

P4

2

1

7

5

8

3

6

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

1

P

M4-FAST 8TP-RJ45-PoE

4

7

2

5

8

3

6

P

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

P

MACH 4002 48+4G RING LED PORT STBY TEST

4

2

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-8TP-RJ45

LED

1

LS/DA 6.1

LED

RL1

6.16 LS/DA

V.24

FAULT

M4-AIR

USB

SELECT RL2

5.1

5.2

5.3

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

MACH 4002-48G+3X MACH 4000 Release

04/08

Technische Unterstützung [email protected]

Die Nennung von geschützten Warenzeichen in diesem Handbuch berechtigt auch ohne besondere Kennzeichnung nicht zu der Annahme, daß solche Namen im Sinne der Warenzeichenund Markenschutz-Gesetzgebung als frei zu betrachten wären und daher von jedermann benutzt werden dürften.

© 2008 Hirschmann Automation and Control GmbH Handbücher sowie Software sind urheberrechtlich geschützt. Alle Rechte bleiben vorbehalten. Das Kopieren, Vervielfältigen, Übersetzen, Umsetzen in irgendein elektronisches Medium oder maschinell lesbare Form im Ganzen oder in Teilen ist nicht gestattet. Eine Ausnahme gilt für die Anfertigungen einer Sicherungskopie der Software für den eigenen Gebrauch zu Sicherungszwecken. Bei Geräten mit eingebetteter Software gilt die Endnutzer-Lizenzvereinbarung auf der mitgelieferten CD. Die beschriebenen Leistungsmerkmale sind nur dann verbindlich, wenn sie bei Vertragsschluß ausdrücklich vereinbart wurden. Diese Druckschrift wurde von Hirschmann Automation and Control GmbH nach bestem Wissen erstellt. Hirschmann behält sich das Recht vor, den Inhalt dieser Druckschrift ohne Ankündigung zu ändern. Hirschmann gibt keine Garantie oder Gewährleistung hinsichtlich der Richtigkeit oder Genauigkeit der Angaben in dieser Druckschrift. Hirschmann haftet in keinem Fall für irgendwelche Schäden, die in irgendeinem Zusammenhang mit der Nutzung der Netzkomponenten oder ihrer Betriebssoftware entstehen. Im übrigen verweisen wir auf die im Lizenzvertrag genannten Nutzungsbedingungen. Printed in Germany (25.4.08) Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 72654 Neckartenzlingen Telefon +49 1805 141538

039 534-001-07-0408

Inhalt Sicherheitshinweise

5

Über dieses Handbuch

11

Legende

11

1

Beschreibung des Gerätes

12

1.1

Grundgerät MACH 4000

13

1.2

Spannungsversorgung 1.2.1 Spannungsversorgung Geräterückseite 1.2.2 Netzteil-Grundgerät M4-POWER

18 19 19

1.3

Lüftereinschub M4-AIR und M4-AIR-T

20

1.4

Integriertes Basisboard 1.4.1 Linker Bereich des Basisboards 1.4.2 Rechter Bereich des Basisboards

21 22 23

1.5

Medienmodule 1.5.1 M4-8TP-RJ45 1.5.2 M4-FAST 8TP-RJ45-PoE 1.5.3 M4-FAST 8-SFP 1.5.4 M4-GIGA 8-SFP

24 25 25 26 26

2

Montage und Inbetriebnahme

27

2.1

Montage des Gerätes 2.1.1 Auspacken und Prüfen 2.1.2 Montage der Medienmodule 2.1.3 Montage der SFP/XFP-Module 2.1.4 Montage des Netzteils an der Geräterückseite 2.1.5 Montage der Netzteileinschübe im Netzteil-Grundgerät M4-POWER 2.1.6 Aufstellen oder Montage des Switch-Grundgerätes im 19"-Rack 2.1.7 Erdung des Gerätes 2.1.8 Montage des Netzteil-Grundgerätes, Verbinden mit dem MACH 4000 2.1.9 Verdrahtung des Meldekontakt-Klemmblockes 2.1.10Anschluss der Versorgungsspannung, Inbetriebnahme 2.1.11Montage der Datenleitungen

27 27 27 28 29

MACH 4000 Release

04/08

29 30 32 32 33 34 35 3

2.1.12Austauschen des Lüftereinschubs M4-AIR / M4-AIR-T

38

2.2

Anzeigenelemente

39

2.3

Grundeinstellungen vornehmen

43

2.4

Demontage 2.4.1 Demontage der Medienmodule 2.4.2 Demontage der SFP/XFP-Module

45 45 45

3

Technische Daten

46

Allgemeine technische Daten Schnittstellen EMV und Festigkeit Netzausdehnung Leistungsaufnahme/Leistungsabgabe Lieferumfang Bestellnummern/Produktbezeichnung Zubehör Zugrundeliegende Normen und Standards Zertifizierungen

46 47 47 47 49 49 50 51 52 52

Weitere Unterstützung

53

4

4

MACH 4000 Release

04/08

Sicherheitshinweise Dieses Handbuch enthält Hinweise, die Sie zu Ihrer persönlichen Sicherheit, sowie zur Vermeidung von Sachschäden beachten müssen. U Bestimmungsgemäßer Gebrauch Bitte beachten Sie folgendes: Das Gerät darf nur für die im Katalog und in der technischen Beschreibung vorgesehenen Einsatzfälle und nur in Verbindung mit von Hirschmann empfohlenen bzw. zugelassenen Fremdgeräten und -komponenten verwendet werden. Der einwandfreie und sichere Betrieb des Produktes setzt sachgemäßen Transport, sachgemäße Lagerung, Aufstellung und Montage sowie sorgfältige Bedienung und Instandhaltung voraus. U Versorgungsspannung Aus Sicherheitsgründen darf die in den Einschubnetzteilen eingebaute Sicherung nicht ausgetauscht werden. V Tauschen Sie ein defektes Einschubnetzteil komplett aus. V Schalten Sie ein Gerät nur ein, wenn das Gehäuse verschlossen ist. Verschließen Sie leere Steckplätze mit Abdeckblenden. V Die Geräte dürfen nur an die auf dem Typschild aufgedruckte Versorgungsspannung angeschlossen werden. V WARNUNG: Installieren Sie in den nicht geerdeten Spannungskabeln für jeden Spannungsversorgungsanschluss eine Eingangssicherung. Verwenden Sie für den AC-Eingang der AC/DC-Netzteileinschübe eine Nenngröße von nicht mehr als 10 A - Charakteristik B. Verwenden Sie für den DC-Eingang der DC-Netzteileinschübe an P1 und P2 eine Nenngröße von nicht mehr als 20 A - Charakteristik Slow Blow. Verwenden Sie simultan an P1 und P2 keine redundante Spannungsversorgung, wenn eine der "+" Verbindungen von P1 oder P2 geerdet ist. Verwenden Sie für die Stromleiter am Spannungseingang der AC/ DC-Netzteileinschübe einen Leitungsquerschnitt von mindestens 1,0 mm². Verwenden Sie für die Stromleiter am Spannungseingang der DCNetzteileinschübe einen Leitungsquerschnitt von mindestens 2,5 mm². V Die DC-Module (M4-...-...VDC 300W) sind für den Betrieb mit Sicherheitskleinspannung ausgelegt. Entsprechend dürfen an die Versorgungsspannungsanschlüsse nur PELV-Spannungskreise oder wahlweise SELV-Spannungskreise mit den Spannungsbeschränkungen gemäß IEC/EN 60950-1 angeschlossen werden. MACH 4000 Release

04/08

5

V Schließen Sie die Netzspannung nur an, wenn die Netzteile mit dem Gehäuse fest verschraubt sind. V Falls Sie das Netzteil-Grundgerät M4-POWER einsetzen: Prüfen Sie die Konfiguration der Anschlussstecker und des Stromversorgungskabels zum Switch-Grundgerät, bevor Sie eine externe Spannung an die M4-POWER-Eingänge anschließen. V Verwenden Sie nur Anschlussleitungen, die für einen Temperaturbereich von 0°C bis 60 °C zugelassen sind. V WARNUNG: Die Stromversorgungskabel zwischen dem Netzteil-Grundgerät M4POWER und dem MACH 4000 sind nicht hot swapable. Beachten Sie die Reihenfolge bei der Verkabelung: Schließen Sie zuerst das/die Stromversorgungskabel zwischen M4-POWER und MACH 4000 an. Schließen Sie danach die Stromversorgung (AC oder DC, je nach Netzteileinschub) für das M4-POWER an. Relevant für Nordamerika: V WARNUNG: Installieren Sie in den nicht geerdeten Spannungskabeln für jeden Spannungsversorgungsanschluss eine Eingangssicherung. Verwenden Sie für den AC-Eingang der AC/DC-Netzteileinschübe eine Nenngröße von nicht mehr als 10 A - Charakteristik Slow Blow. Verwenden Sie für den DC-Eingang der DC-Netzteileinschübe an P1 und P2 eine Nenngröße von nicht mehr als 20 A - Charakteristik Slow Blow. Verwenden Sie simultan an P1 und P2 keine redundante Spannungsversorgung, wenn eine der "+" Verbindungen von P1 oder P2 geerdet ist. Verwenden Sie für die Stromleiter am Spannungseingang der AC/ DC-Netzteileinschübe einen Leitungsquerschnitt von mindestens AWG16. Verwenden Sie für die Stromleiter am Spannungseingang der DCNetzteileinschübe einen Leitungsquerschnitt von mindestens AWG12. V Nur Kupferdraht/Leiter der Klasse 1 60/75°C oder 75°C verwenden. U Schirmungsmasse Die Schirmungsmasse der anschließbaren Twisted-Pair-Leitungen ist elektrisch leitend mit der Frontblende verbunden. V Achten Sie beim Anschließen eines Kabelsegmentes mit kontaktiertem Schirmungsgeflecht auf mögliche Erdschleifen.

6

MACH 4000 Release

04/08

U Gehäuse Das Öffnen des Gehäuses bleibt ausschließlich den von Hirschmann autorisierten Technikern vorbehalten. Die Erdung erfolgt über die Stromversorgungsanschlüsse. V Achten Sie auf die Übereinstimmung der elektrischen Installation mit lokalen oder nationalen Sicherheitsvorschriften. V Die Lüftungsschlitze dürfen nicht bedeckt werden, so dass die Luft frei zirkulieren kann. V Der Abstand zu den Lüftungsschlitzen des Gehäuses muss mindestens 10 cm betragen. V Stecken Sie niemals spitze Gegenstände (schmale Schraubendreher, Drähte oder Ähnliches) in das Innere des Produktes! Es besteht die Gefahr eines elektrischen Schlags. V Verschließen Sie leere Steckplätze mit Abdeckblenden. V Module, Lüfter und Netzteile eines eingeschalteten Gerätes dürfen nur von einer Elektrofachkraft ein- oder ausgebaut werden. V Das Basis Board darf nicht ausgebaut werden. Das Ausbauen des Basis Boards führt zum Garantieverlust. V Das Gehäuse ist in horizontaler Lage einzubauen. V Nach dem Ausschalten des Gerätes drehen sich die Lüfterrotoren noch einige Sekunden weiter. Greifen Sie nicht in einen sich drehenden Lüfter! V Der Innenbereich der Grundgeräte ist kein Benutzerbereich! Greifen Sie wegen hoher Energiedichten nicht in den Innenbereich eines eingeschalteten Gerätes. V Das Gerät hat bei voller Bestückung mit Medienmodulen ein Gewicht von bis zu 10 kg. Beachten Sie die gesetzlich festgelegten Höchstwerte beim Handhaben von Lasten. V Falls Sie das Gerät in einem 19"-Schaltschrank betreiben: Montieren Sie Gleitschienen/Tragschienen zur Aufnahme des Gerätegewichtes (siehe “Aufstellen oder Montage des Switch-Grundgerätes im 19"Rack” auf Seite 30). WARNUNG: Bei Montage im 19"-Schaltschrank ohne Gleitschienen/Tragschienen kann es durch Verstärkung der Vibration zu Beschädigungen am Gerät und/oder dessen Einschüben kommen. WARNUNG: Achten Sie beim Einbau darauf, dass die Lüftungsschlitze frei bleiben, da es sonst zu Schäden durch Überhitzung kommen kann.

MACH 4000 Release

04/08

7

U Umgebung Das Gerät darf nur bei der angegebenen maximalen Umgebungslufttemperatur und bei der angegebenen relativen Luftfeuchtigkeit (nicht kondensierend) betrieben werden. V Wählen Sie den Montageort so, dass die in den Technischen Daten angegebenen klimatischen Grenzwerte eingehalten werden. V Verwendung nur in einer Umgebung mit Verschmutzungsgrad gemäß den Technischen Daten. U Anforderung an die Qualifikation des Personals Qualifiziertes Personal im Sinne dieser Betriebsanleitung bzw. der Warnhinweise sind Personen, die mit Aufstellung, Montage, Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und die über die ihrer Tätigkeit entsprechenden Qualifikationen verfügen, wie z.B.: D Ausbildung oder Unterweisung bzw. Berechtigung, Stromkreise und Geräte bzw. Systeme gemäß den aktuellen Standards der Sicherheitstechnik ein- und auszuschalten, zu erden und zu kennzeichnen; D Ausbildung oder Unterweisung gemäß den aktuellen Standards der Sicherheitstechnik in Pflege und Gebrauch angemessener Sicherheitsausrüstungen; D Schulung in erster Hilfe. U Allgemeine Sicherheitsvorschriften Dieses Gerät wird mit Elektrizität betrieben. Beachten Sie genauestens die in der Betriebsanleitung vorgeschriebenen Sicherheitsanforderungen an die anzulegenden Spannungen! Bei Nichtbeachten der Warnhinweise können deshalb schwere Körperverletzungen und/oder Sachschäden auftreten. V Nur entsprechend qualifiziertes Personal sollte an diesem Gerät oder in dessen Nähe arbeiten. Dieses Personal muss gründlich mit allen Warnungen und Instandhaltungsmaßnahmen gemäß dieser Betriebsanleitung vertraut sein. V Der einwandfreie und sichere Betrieb dieses Gerätes setzt sachgemäßen Transport, fachgerechte Lagerung und Montage sowie sorgfältige Bedienung und Instandhaltung voraus. V Nehmen Sie nur unbeschädigte Teile in Betrieb! V Verwenden Sie die Geräte nur wie im vorliegenden Handbuch vorgesehen. Beachten Sie insbesondere alle Warnungen und sicherheitsrelevanten Hinweise. V Eventuell notwendige Arbeiten an der Elektroinstallation dürfen nur von einer hierfür ausgebildeten Fachkraft durchgeführt werden.

8

MACH 4000 Release

04/08

WARNUNG: LED- oder LASER-Komponenten gemäß IEC 60825-1 (2001): LASER KLASSE 1 - CLASS 1 LASER PRODUCT. LICHT EMITTIERENDE DIODE KLASSE 1 - CLASS 1 LED PRODUCT. U Nationale und internationale Sicherheitsvorschriften V Achten Sie auf die Übereinstimmung der elektrischen Installation mit lokalen oder nationalen Sicherheitsvorschriften. U ESD-Hinweise Die Medienmodule sind mit elektrostatisch empfindlichen Bauteilen bestückt. Diese können durch die Einwirkung eines elektrischen Feldes oder durch Ladungsausgleich beim Berühren der Karte zerstört oder in der Lebensdauer beeinflusst werden. Aus diesem Grund sind die Karten bei der Auslieferung in einem leitfähigen ESD-Schutzbeutel verpackt. Die Verpackung ist wieder verwendbar. Beachten Sie unbedingt die folgenden Schutzmaßnahmen für elektrostatisch gefährdete Baugruppen: V Stellen Sie einen elektrischen Potentialausgleich zwischen sich und ihrer Umgebung her, z. B. durch ein Handgelenkband, das Sie an das Grundgerät (Rändelschraube einer Interface-Karte) anklemmen. Ein Grundgerät ist bei angeschlossenem Netzkabel über den Netzanschluss geerdet. V Nehmen Sie erst jetzt die Karte aus dem leitfähigen Beutel heraus. V Lagern Sie die Karten außerhalb des Grundgerätes nur in einem leitfähigen ESD-Schutzbeutel. Für den sicheren Umgang mit elektrostatisch gefährdeten Baugruppen sind ESD-Schutz-Feldausrüstungen erhältlich. Weitere Informationen über elektrostatisch gefährdete Baugruppen finden Sie in der DIN/IEC 47 (Sec) 1330; Ausgabe Februar 1994 und DIN EN 100 015. U Hinweis zur CE-Kennzeichnung Die Geräte stimmen mit den Vorschriften der folgenden Europäischen Richtlinien überein: 73/23/EWG, 89/336/EWG (geändert durch RL 91/263/EWG, 92/31/EWG und 93/68/EWG). Die EU-Konformitätserklärung wird gemäß der obengenannten EURichtlinien für die zuständigen Behörden zur Verfügung gehalten bei: Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 D-72654 Neckartenzlingen Telefon 07127 14 1480

MACH 4000 Release

04/08

9

Das Produkt ist einsetzbar im Wohnbereich (Wohnbereich, Geschäftsund Gewerbebereiche sowie Kleinbetriebe) sowie im Industriebereich. D Störfestigkeit: EN 61000-6-2:2001 D Störaussendung: EN 55022:1998 + A1 2000 + A2 2003, Class A WARNUNG: Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen durchzuführen. Voraussetzung für die Einhaltung der EMV-Grenzwerte ist die strikte Einhaltung der in dieser Beschreibung und Betriebsanleitung angegebenen Aufbaurichtlinien. U FCC-Hinweis: Es wurde nach entsprechender Prüfung festgestellt, dass dieses Gerät den Anforderungen an ein Digitalgerät der Klasse A gemäß Teil 15 der FCC-Vorschriften entspricht. Diese Anforderungen sind darauf ausgelegt, einen angemessenen Schutz gegen Funkstörungen zu bieten, wenn das Gerät im gewerblichen Bereich eingesetzt wird. Das Gerät erzeugt und verwendet Hochfrequenzen und kann diese auch ausstrahlen, und wenn es nicht entsprechend dieser Betriebsanleitung installiert und benutzt wird, kann es Störungen des Funkverkehrs verursachen. Der Betrieb dieses Gerätes in einem Wohnbereich kann ebenfalls Funkstörungen verursachen; der Benutzer ist in diesem Fall verpflichtet, Funkstörungen auf seine Kosten zu beseitigen. U Recycling Hinweis: Dieses Produkt ist nach seiner Verwendung entsprechend den aktuellen Entsorgungsvorschriften Ihres Landkreises / Landes / Staates als Elektronikschrott einer geordneten Entsorgung zuzuführen.

10

MACH 4000 Release

04/08

Über dieses Handbuch Folgende Handbücher sind als PDF-Dateien auf der beigelegten CD ROM enthalten: D D D D D D

Anwender-Handbuch „Installation“ Anwender-Handbuch „Grundkonfiguration“ Anwender-Handbuch „Redundanzkonfiguration“ Anwender-Handbuch "Routerkonfiguration" Referenz-Handbuch „Web-based Interface“ und Referenz-Handbuch „Command Line Interface“

Die Netzmanagement Software HiVision bietet Ihnen weitere Möglichkeiten zur komfortablen Konfiguration und Überwachung: D D D D D D

Ereignislogbuch. Konfiguration von „System Location“ und „System Name“. Konfiguration des Netzadressbereichs und der SNMP-Parameter. Speichern der Konfiguration auf den Switch. Gleichzeitige Konfiguration mehrerer Switches. Konfiguration der Portanzeigefarbe Rot für einen Verbindungsfehler.

Mit der Netzmanagement Software Industrial HiVision erhöhen Sie Ihre Netzwerksicherheit in industriellen Anwendungsgebieten: D D D D D

ETHERNET-Frühwarnsystem Einfache Überwachung von industriellen Netzen Schnelle Visualisierung Schnittstelle zu Diagnose und Konfigurationsprogrammen Kostengünstiger Einstieg

Legende Die in diesem Handbuch verwendeten Auszeichnungen haben folgende Bedeutungen: D

Aufzählung

V

Arbeitsschritt

U

Zwischenüberschrift

MACH 4000 Release

04/08

11

1

Beschreibung des Gerätes

Das modulare, industrietaugliche Gigabit-ETHERNET-System MACH 4000 wird als industrielles Backbonesystem eingesetzt sowie in Applikationen mit hohem Datenaufkommen wie z.B. Voice/Video over IP. Beim MACH 4000 handelt es sich um ein modulares, industrietaugliches Gigabit-ETHERNET-System im 19" Gehäuse, welches auch für den Einsatz als industrielles Backbone-System geeignet ist. Die MACH 4000 Geräte sind konzipiert für die speziellen Anforderungen der industriellen Automatisierung. Sie erfüllen die relevanten Industrie-Normen, bieten eine sehr hohe Betriebssicherheit auch unter extremen Bedingungen, langjährige Verfügbarkeit und Flexibilität. Die Spannungsversorgung erfolgt über ein AC- oder DC-Netzteil an der Geräterückseite oder redundant über ein Netzteil-Grundgerät mit bis zu drei hot-swap fähigen Netzteileinschüben. Die Switches und das Netzteil-Grundgerät eignen sich für die Montage im 19"-Rack. Das HIPER-Ring Redundanzkonzept ermöglicht eine schnelle Rekonfiguration und eine einfache Projektierung mit nur einer zusätzlichen Verbindung. Die Diagnose-LEDs zur Anzeige der Betriebsparameter ermöglichen einen schnellen Überblick. Über einen Web-Browser, über Telnet, mit einer Managementsoftware (z.B. HiVision) oder lokal am Switch (V.24-Schnittstelle) steht Ihnen ein komfortables Management zur Verfügung. Der MACH 4000 ermöglicht den Aufbau von geswitchten Industrial ETHERNET-Netzen nach der Norm IEEE 802.3 und 802.3u mit Kupfertechnik oder Lichtwellenleiter in Linien- und Ringstruktur. Endgeräte und weitere Infrastukturkomponenten lassen sich über Twisted-Pair-Kabel, Multimode-LWL und Singlemode-LWL anschließen. Die Twisted-Pair-Ports unterstützen Autocrossing, Autonegotiation und Autopolarity. Das Medienmodul M4-FAST 8TP-RJ45-PoE unterstützt Power over ETHERNET nach IEEE 802.3af. Die Geräte bieten Ihnen, abhängig von der gewählten Software, einen großen Funktionsumfang: D Redundanzfunktionen (Rapid Spanning Tree, Redundante Ringstruktur, HIPER-Ring, Redundante Kopplung, Link Aggregation, Redundante Stromversorgung) D Schutz vor unberechtigtem Zugriff D Systemzeit im Netz synchronisieren D Netzlaststeuerung D Funktionsdiagnose D Diagnose (Hardware-Selbsttest)

12

MACH 4000 Release

04/08

D D D D D D D D D D D

Reset Priorität VLAN Topologie-Erkennung Web-based Interface Command Line Interface CLI SNMP 802.1x Port-Authentifizierung Real Time Clock Routing Access Control List ACL

Die Ergänzung der Backbone Switches der MACH Familie durch die Switches der Open Rail Familie RS20/RS30/RS40 und der MICE Familie, das drahtlose Übertragungssystem BAT, das Sicherheitssystem EAGLE und Produkte für den Kontrollraum LION gewährleisten eine durchgängige Kommunikation über alle Ebenen des Unternehmens hinweg.

Grundgerät MACH 4000

Abb. 1:

Aufbau des Grundgerätes (Beispiel: MACH 4002-48+4G)

MACH 4000 Release

zw e M i sc el h de al ko tba nt re ak te (P or 1 ts 6 6. TP 1 -P bi o s rt 6. s ex 16 te V ) rn .2 4 es Z M ug an a ag ng U em für SB e -B nt uc hs e

LE



fte D Be rei -A s ns nz ch ch ei rif ge tu ub e n SE lemg d LE e er CT nte LE -Ta s D A ter n z el e em ig ene4 (P C te o or m ts b 5. o1 P bi or s ts 5. 4)

M e (E di in en sc m M hubodu ed ) l1 (E i in en sc m Ba hubodu ) l3 (insis bo t e Po g a rt rie rd 5. rt 1 ) bi s M 5. e 4 (E di in en sc m M hubodu ed ) l2 (E i in en sc m Ba hubodu ) l4 (insis bo t e Po g a rt rie rd 6. rt 1 ) bi s G 6. er 16 N ät et e Ex zt rü e c M t. A il kse 4 Ex -P nsc ite: O M t. A W hlu 4- n ER ß zu PO sc W hlu ER ß zu

1.1

04/08

13

Abb. 2: RL1 FDX

RM L/D

1000

RL2

P2

RING LED PORT STBY TEST

P1

P

LED

2

AN

Basisboard (integriert) Port 5.1 bis 5.3, 10 Gbit/s, XFP

Medienmodul 1 (Einschub) Port 1.1 bis 1.8, 10/100/1000 Mbit/s

3

4

5

6

7

8 1

RUN

RL1

RL2 1000

LED RING PORT STBY TEST

FDX

RM

P2

LED

2

AN

FAN

P3

SLOT.PORT

RUN

1

TP/FO

SELECT

MACH 4002 48+4G

M4-8TP-RJ45

2

3

6.1

4

6.2

5

6.3

6.5 6.6

LED

5.1

6

5

4 8

7

LS/DA

P

P

6.7

M4-FAST 8SFP

6.8

RL2

RL1

LS/DA 6.1

M4-FAST 8TP-RJ45-PoE

6

7

8 1

5.3

7 8

P

P

RL2

RL1

LS/DA 6.1

M4-FAST 8TP-RJ45-PoE

M4-FAST 8SFP

2

3

4

5

6

7

8

2

6.3 6.4

6.5 6.6

3

6.7 6.8

4

5

6

7

8

V.24

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

V.24

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

1

6.1 6.2

MACH 4002-24G+3X

5.2

6

5

4

LS/DA

1

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

MACH 4002-24G

6.4

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

1

LED

3

M4-FAST 8SFP

SELECT

MACH 4002 48+4G

2

P4

1

TP/FO

3 1

P1

L/D

2

MEDIA SLOTS

P

M4-AIR

4 2

FAN

P3

Basisboard (integriert) Port 6.1 bis 6.8, 100/1000 Mbit/s, SFP (alternativ zu den RJ45-Ports 6.1 bis 6.8)

Medienmodul 1 (Einschub) Port 1.1 bis 1.8, 10/100/1000 Mbit/s

P4

1

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

3

M4-FAST 8SFP

M4-8TP-RJ45

2 4 2

3 1 SLOT.PORT

MEDIA SLOTS

FAULT

14 FAULT

M4-AIR 5

3

USB

8

7

4 5 6

1 2 3

USB

8

7

LS/DA

4

6

2

LS/DA 1

R

P

R

P

Basisboard (integriert), RJ45 Port 6.1 bis 6.8, 10/100/1000 Mbit/s

Medienmodul 2 (Einschub) Port 2.1 bis 2.8, 10/100/1000 Mbit/s

Basisboard (integriert), RJ45 Port 6.1 bis 6.16, 10/100/1000 Mbit/s

Medienmodul 2 (Einschub) Port 2.1 bis 2.8, 10/100/1000 Mbit/s

Je nach MACH 4000 Gerätevariante stehen Ihnen folgende Ports und Slots zur Bestückung mit Medienmodulen zur Verfügung:

Ports und Medienmoduleinschübe am MACH 4002-24...

Release

MACH 4000

04/08

Release

04/08

P2 RL2 1000

RING LED PORT STBY TEST

P1 RL1 FDX

P

L/D

LED

2

AN

FAN

P3

SLOT.PORT

P4 RUN

1

TP/FO

Basisboard (integriert) Port 5.1 bis 5.3, 10 Gbit/s, XFP

Medienmodul 1 (Einschub) Port 1.1 bis 1.8, 10/100/1000 Mbit/s

Medienmodul 3 (Einschub) Port 3.1 bis 3.8, 10/100/1000 Mbit/s

6

7

8 1

P2 RL2 1000

RING LED PORT STBY TEST

P1 RL1 FDX

LED

2

AN

P4

1

2

3

4

DA

5

LS

DA

5.3

LS

RUN

6

7

8 1

P1 RL1

P2 RL2 1000

LED RING PORT STBY TEST

FDX

P RM

LED

2

AN

FAN

P3

SLOT.PORT

RUN

1

TP/FO

SELECT

MACH 4002 48+4G

M4-8TP-RJ45

3

4

6.2

5

6.3

LED

5.1

DA

8

7

P

P

5.4

LS

DA

RL2

RL1

LS/DA 6.1

M4-FAST 8TP-RJ45-PoE

M4-FAST 8SFP 1

2

6.5 6.6

6

5

4 8

7

LS/DA

P

P

6.7

6.8

RL2

RL1

LS/DA 6.1

M4-FAST 8TP-RJ45-PoE

M4-FAST 8SFP

6

7

8 1

6.1 6.2

6.3 6.4

5.3

8

7

P

P

RL2

RL1

LS/DA 6.1

M4-FAST 8TP-RJ45-PoE

M4-FAST 8SFP

4

5

6

7

8

1

2

6.5 6.6

3

6.7 6.8

4

6.9 6.10

5

6.11 6.12

6

6.13 6.14

7

6.15 6.16

8

V.24

2

6.3 6.4

6.5 6.6

3

6.7 6.8

4

6.9 6.10

5

6.11 6.12

6

6.13 6.14

7

6.15 6.16

8

V.24

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

5

2 3

8

5

USB

7

4

6

2

6.16 LS/DA

V.24

USB

8

7

3

1

USB

8

7

LS/DA

4

6

1

6.16 LS/DA

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

1

6.1 6.2

5

3

LS/DA

4

6

2

LS/DA 1

6.16 LS/DA

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

MACH 4002-48G+3X

5.2

6

5

4

LS/DA

3

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

MACH 4002-48G

6.4

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

2

6.1

2

1

LED

3

M4-FAST 8SFP

SELECT

MACH 4002 48+4G

3 1

P4

1

TP/FO

6

5

4

LS/DA

MACH 4002 48+4G

5.2

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

LS

MEDIA SLOTS 4 2

FAN

P3

SLOT.PORT

M4-8TP-RJ45

M4-FAST 8SFP

5.1

3

4 2

LED

2

P

L/D

5

3 1

L/D

M4-AIR

4

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

3

MEDIA SLOTS

RM

M4-AIR

Basisboard (integriert) Port 6.1 bis 6.8, 100/1000 Mbit/s, SFP (alternativ zu den RJ45-Ports 6.1 bis 6.8)

Medienmodul 1 (Einschub) Port 1.1 bis 1.8, 10/100/1000 Mbit/s

Medienmodul 3 (Einschub) Port 3.1 bis 3.8, 10/100/1000 Mbit/s

SELECT

MACH 4002 48+4G

M4-8TP-RJ45

2

3

1 2

M4-FAST 8SFP

3 1 4 2

MEDIA SLOTS

RM

M4-AIR

Basisboard (integriert) Port 5.1 bis 5.4, RJ45 10/100/1000 Mbit/s, alternativ SFP 1000 Mbit/s

Medienmodul 1 (Einschub) Port 1.1 bis 1.8, 10/100 Mbit/s

Medienmodul 3 (Einschub) Port 3.1 bis 3.8, 10/100 Mbit/s FAULT FAULT

MACH 4000 FAULT

Abb. 3:

Ports und Medienmoduleinschübe am MACH 4002-48...

15

R

P

R

P

R

P

Basisboard (integriert), RJ45 Port 6.1 bis 6.16, 10/100/1000 Mbit/s

Medienmodul 2 (Einschub) Port 2.1 bis 2.8, 10/100/1000 Mbit/s

Medienmodul 4 (Einschub) Port 4.1 bis 4.8, 10/100/1000 Mbit/s

Basisboard (integriert), RJ45 Port 6.1 bis 6.16, 10/100/1000 Mbit/s

Medienmodul 2 (Einschub) Port 2.1 bis 2.8, 10/100/1000 Mbit/s

Medienmodul 4 (Einschub) Port 4.1 bis 4.8, 10/100/1000 Mbit/s

Basisboard (integriert), RJ45 Port 6.1 bis 6.16, 10/100 Mbit/s

Medienmodul 2 (Einschub) Port 2.1 bis 2.8, 10/100 Mbit/s

Medienmodul 4 (Einschub) Port 4.1 bis 4.8, 10/100 Mbit/s

Abb. 4:

16

MACH 4000, Anzahl Ports und Medienmodule

Release

MACH 4000

04/08

-

MACH 4002-48G

MACH 4002-24G+3X

MACH 4002-48G+3X

3)

2)

48

24

48

24

4

TPPorts 10/100 1000 Mbit/s

-

-

8

8

4

3

3

-

-

-

Combo XFPPorts Slots TP/SFP 10 10/100 Gbit/s 1000 Mbit/s

M4-8TP-RJ45, M4-8TP-RJ45-PoE oder M4-FAST 8-SFP

SFP 100/1000 Mbit/s

SFP 1000 Mbit/s

-

MACH 4002-24G

1)

48

TPPorts 10/100 Mbit/s

Maximale Port-Anzahl

MACH 4002-48+4G

MACH 4000Grundgerät

-

-

-

-

16

TPPorts 10/100 Mbit/s

16

8

8

-

-

TPPorts 10/100 1000 Mbit/s

Maximale Anzahl Medienmodule

-

8 2)

-

3

3

-

8 2)

-

-

4 1)

-

-

-

-

4 3)

4

2

4

2

-

Combo XFP- 10/100 10/100 Ports Slots Mbit/s 1000 Mbit/s TP/SFP 10 10/100 Gbit/s 1000 Mbit/s

Anzahl fest installierte Ports (Basisboard)

106 W

157 W

110 W

163 W

137 W

Max. PoELeistung

Die Geräte sind konform zu den Spezifikationen der Norm D ISO/IEC 8802-3u 100BASE-TX/-1000BASE-TX D ISO/IEC 8802-3 100BASE-FX D ISO/IEC 8802-3 1000BASE-SX/LX D ISO/IEC 8802-3 10GBASE-SR/LR Die Grundgeräte MACH 4000 sind 2 HE hoch (ca. 88mm) und bieten Ihnen, je nach Gerätevariante und Bestückung mit Medienmodulen, D bis zu 48 Fast ETHERNET-Ports D bis zu 48 Gigabit ETHERNET-Ports D bis zu drei 10Gigabit ETHERNET-Ports. (siehe Tabelle “MACH 4000, Anzahl Ports und Medienmodule” auf Seite 16) Sie haben die Möglichkeit, die Grundgeräte mit unterschiedlichem Funktionsumfang zu bestellen (siehe Tabelle “Bestellnummern/Produktbezeichnung” auf Seite 50). Die mitgelieferte Software legt den Funktionsumfang fest: D Software Layer 2 Professional (L2P) D Software Layer 3 Enhanced (L3E), statisches Routing D Software Layer 3 Professional (L3P), Multicast Routing Ein Grundgerät verfügt je nach Gerätevariante über zwei oder vier Steckplätze für Medienmodule (Module 1-2 bwz. 1-4), die hot swap-fähig sind und je 8 Fast-ETHERNET-/Gigabit-ETHERNET-Ports zur Verfügung stellen. Die Medienmodule unterscheiden sich in der Anzahl der Schnittstellen und dem Medientyp zum Anschluss von Segmenten. Unterhalb der Module befindet sich das integrierte Basisboard. Es verfügt D beim MACH 4002-48+4G über 4 Gigabit-ETHERNET-Ports (Comboports, d.h. SFP-Schächte für 1000BASE-SX bzw. 1000BASE-LX und RJ45-Buchsen für 10/100/1000BASE-TX, Modul 5) und 16 Fast ETHERNET-Ports (10/100BASE-TX, Modul 6). D beim MACH 4002-24G über 8 Gigabit-ETHERNET-Ports (SFP-Schächte für 100BASE-FX, 1000BASE-SX/LX, Modul 6, alternativ zu den RJ45Ports 6.1 bis 6.8) und 8 Gigabit-ETHERNET RJ45-Ports (10/100/ 1000BASE-TX, Modul 6). D beim MACH 4002-48G über 8 Gigabit-ETHERNET-Ports (SFP-Schächte für 100BASE-FX, 1000BASE-SX/LX, Modul 6, alternativ zu den RJ45Ports 6.1 bis 6.8) und 16 Gigabit-ETHERNET RJ45-Ports (10/100/ 1000BASE-TX, Modul 6). D beim MACH 4002-24G+3XP über drei 10Gigabit-ETHERNET-Ports (XFP-Schächte für 10GBASE-SR/LR, Modul 5) und 8 Gigabit-ETHERNET RJ45-Ports (10/100/1000BASE-TX, Modul 6). D beim MACH 4002-24G+3XP über drei 10Gigabit-ETHERNET-Ports (XFP-Schächte für 10GBASE-SR/LR, Modul 5) und 16 Gigabit-ETHERNET RJ45-Ports (10/100/1000BASE-TX, Modul 6).

MACH 4000 Release

04/08

17

Das Basisboard besitzt an seiner Frontseite neben den 10Gigabit- (falls vorhanden), Gigabit- und Fast ETHERNET-Ports folgende Anschlüsse: D eine USB-Buchse für den Anschluss eines AutoConfiguration Adapters ACA21-USB, D eine V.24-Buchse für den Netzmanagementzugang D zwei Meldekontakte, die gemeinsam auf einer Buchse integriert sind. Der LED-Anzeigenblock an der linken Seite des Basisboards informiert Sie über den Gerätezustand. Über den SELECT-Taster legen Sie die Bedeutung der LED-Anzeigen fest. Vorne links im MACH 4000 Grundgehäuse befindet sich ein austauschbarer Lüftereinschub. An der Geräterückseite befindet sich ein Steckplatz für ein Netzteil: D AC-Netzteileinschub 300W D 24 VDC-Netzteileinschub 300W (2 Anschlüsse über Dioden gekoppelt) D 48 VDC-Netzteileinschub 300W (2 Anschlüsse über Dioden gekoppelt) Ebenfalls an der Geräterückseite befinden sich zwei externe Eingänge (Spannungseingang Nr. 3 + 4) zur redundanten Spannungsversorgung über das Netzteil-Grundgerät M4-POWER. Das Netzteil-Grundgerät M4-POWER ermöglicht eine redundante Stromversorgung. Das/die Stromversorgungskabel zwischen M4-POWER und MACH 4000 werden an der Geräterückseite des MACH 4000 angeschlossen. M4-POWER bietet Ihnen 3 Steckplätze für Netzteileinschübe: D AC-Netzteileinschub 300W D 24 VDC-Netzteileinschub 300W (2 Anschlüsse über Dioden gekoppelt) D 48 VDC-Netzteileinschub 300W (2 Anschlüsse über Dioden gekoppelt).

1.2

Spannungsversorgung

An der Geräterückseite befindet sich ein Einschubplatz für ein Netzteil (AC oder DC) sowie zwei Eingänge zur redundanten Spannungsversorgung über das Netzteil-Grundgerät M4-POWER.

18

MACH 4000 Release

04/08

Steckplatz für Netzteileinschub (Spannungseingang Nr. 1 und, falls vorhanden, Nr. 2) M4-POWER-Anschluss (Spannungseingang Nr. 3, extern) M4-POWER-Anschluss (Spannungseingang Nr. 4, extern) Abb. 5:

Geräterückseite des MACH 4000 Grundgerätes

1.2.1

Spannungsversorgung Geräterückseite

U Netzteileinschübe für Switch-Grundgerät MACH 4000 D M4-S-AC/DC 300W D M4-S-24VDC 300W, 2 Eingänge für redundante Stromversorgung D M4-S-48VDC 300W, 2 Eingänge für redundante Stromversorgung siehe “Bestellnummern/Produktbezeichnung” auf Seite 50. Hinweis: Die Netzteileinschübe des Netzteil-Grundgerätes M4-POWER können nicht für das Switch-Grundgerät verwendet werden.

M4-S-AC/DC 300W

M4-S-48VDC 300W M4-S-24VDC 300W

1.2.2

Netzteil-Grundgerät M4-POWER

Das Netzteil-Grundgerät M4-POWER dient der redundanten Stromversorgung. Es verfügt über drei Steckplätze für Netzteileinschübe. Die Netzteileinschübe sind während des Betriebes (hot-swapable) austauschbar. Mit einem Netzteil-Grundgerät M4-POWER können Sie, je nach Bestückung mit Netzteileinschüben, die redundante Stromversorgung für mehrere MACH 4000 Geräte realisieren. V Verwenden Sie für die Verbindung von den Netzteilen des M4-POWER zum M4-POWER-Anschluss an der Geräterückseite des MACH 4000 das den Netzteileinschüben M4-P-xx beiliegende Stromversorgungskabel. MACH 4000 Release

04/08

19

Netzteileinschub 1

Netzteileinschub 2

Netzteileinschub 3

Netzteil-Grundgerät M4-POWER, Gerätefront (Bestückung mit bis zu 3 Netzteileinschüben)

1 2 3 Netzteil-Grundgerät M4-POWER, Geräterückseite

Abb. 6:

Netzteil-Grundgerät M4-POWER

U Netzteileinschübe für Netzteil-Grundgerät M4-POWER D M4-P-AC/DC 300W D M4-P-24VDC 300W, 2 Eingänge für redundante Stromversorgung D M4-P-48VDC 300W, 2 Eingänge für redundante Stromversorgung siehe “Bestellnummern/Produktbezeichnung” auf Seite 50. Hinweis: Die Netzteileinschübe des Switch-Grundgerätes können nicht für das Netzteil-Grundgerät verwendet werden.

1.3

Lüftereinschub M4-AIR und M4-AIR-T

An der Frontseite des MACH 4000-Gehäuses befindet sich links der Lüftereinschub M4-AIR bzw. M4-AIR-T. Sie können den Lüftereinschub während des Betriebes austauschen (siehe “Austauschen des Lüftereinschubs M4AIR / M4-AIR-T” auf Seite 38). D M4-AIR: Lüftereinschub für Switch-Grundgerät MACH 4000 ohne Temperatursensor. D M4-AIR-T: Lüftereinschub für Switch-Grundgerät MACH 4000 mit temperaturabhängiger Lüfterdrehzahl. Die Lüfterdrehzahl des M4-AIR-T kann temperaturabhängig gesteuert oder konstant auf Maximalwert gehalten werden.

20

MACH 4000 Release

04/08

Hinweis: Die UL-Zertifizierung für die MACH 4000-Familie umfaßt den M4-AIR-T noch nicht. Für UL-Konformität verwenden Sie den Lüftereinschub M4-AIR.

M4-AIR

M4-AIR-T MEDIA SLOTS 3 1

MEDIA SLOTS 3 1

4 2 SLOT.PORT

4 2 SLOT.PORT

LED

LED

P

P1

P2

P3

P4

P

P1

P2

P3

P4

RM

RL1

RL2

FAN

RUN

RM

RL1

RL2

FAN

RUN

L/D

FDX

1000

AN

TP/FO

L/D

FDX

1000

AN

TP/FO

RING LED PORT STBY TEST PoE

RING LED PORT STBY TEST PoE

1

1

M4-AIR-T

M4-AIR

Abb. 7:

Lüftereinschübe M4-AIR und M4-AIR-T

U DIP-Schalter "USER DIP" beim Lüftereinschub M4-AIR-T Schalterstellung Fan Fullspeed Silent Fullspeed

USER DIP

Fan Fullspeed Silent

1.4

Silent

Funktion

Vorteil

Temperatursensor-Überwachung deaktiviert, Lüfterdrehzahl konstant hoch Temperatursensor-Überwachung aktiviert, Lüfterdrehzahl temperaturabhängig (Werkseinstellung)

Gleichbleibend hoher Luftdurchsatz über den gesamten Betriebstemperaturbereich Niedrigerer Geräuschpegel des Lüfters im Bürotemperaturbereich

Integriertes Basisboard

Das integrierte Basisboard bietet Ihnen, abhängig von der Gerätevariante, eine unterschiedliche Anzahl und Art von Ports (siehe Abbildung “MACH 4000, Anzahl Ports und Medienmodule” auf Seite 16, Spalte "Fest installierte Ports (Basisboard)"). LS/DA 6.1

LED

RL1

6.16 LS/DA

FAULT

MACH 4002 48+4G

V.24

USB

V.24

USB

SELECT RL2 LS

DA

LS

5.1

DA

LS

5.2

DA

LS

5.3

DA

6.1 6.2

5.4

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

Basisboard MACH 4002-48+4G LS/DA 6.1

LED

RL1

FAULT

MACH 4002 48+4G

SELECT RL2

6.1

6.2

6.3

6.4

6.5

6.6

6.7

6.8

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

Basisboard MACH 4002-24G

MACH 4000 Release

04/08

21

LS/DA 6.1

LED

RL1

6.16 LS/DA

FAULT

MACH 4002 48+4G

V.24

USB

V.24

USB

SELECT RL2

6.1

6.2

6.4

6.3

6.5

6.6

6.8

6.7

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

Basisboard MACH 4002-48G LS/DA 6.1

LED

RL1

FAULT

MACH 4002 48+4G

SELECT RL2

5.1

5.2

6.1 6.2

5.3

6.3 6.4

6.5 6.6

6.7 6.8

Basisboard MACH 4002-24G+3X LS/DA 6.1

LED

RL1

6.16 LS/DA

V.24

FAULT

MACH 4002 48+4G

USB

SELECT RL2

5.1

5.2

6.1 6.2

5.3

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

Basisboard MACH 4002-48G+3X

1.4.1

Linker Bereich des Basisboards

U Vier Gigabit ETHERNET-Ports (Combo) beim MACH 4002-48+4G Im linken Teil des Basisboards befinden sich vier Gigabit ETHERNETPorts (Ports Nummer 5.1 bis 5.4) zum Anschluss von Netzsegmenten. Sie sind als RJ45-Buchse mit jeweils zwei integrierten LEDs und SFPSchacht ausgeführt.

LS

5.1

DA

LS

5.2

DA

LS

5.3

DA

LS

DA

5.4

Ist ein SFP-Aufsteckmodul montiert, wird die RJ45-Buchse abgeschaltet. Die LEDs gelten jeweils für den aktiven Port. Mittels SELECT-Taster kann der TP- oder der FO-Anschluss geprüft werden. Bestellnummern für SFP-Aufsteckmodule siehe “Bestellnummern/Produktbezeichnung” auf Seite 50. U Acht Gigabit ETHERNET-Ports (Combo) beim MACH 4002-24G und MACH 4002-48G Im linken Teil des Basisboards befinden sich acht Gigabit ETHERNETPorts (Ports Nummer 6.1 bis 6.8) zum Anschluss von Netzsegmenten. Sie sind als SFP-Schacht ausgeführt und alternativ zu den RJ45-Ports 6.1 bis 6.8. verwendbar.

22

MACH 4000 Release

04/08

6.1

6.2

6.4

6.3

6.5

6.6

6.7

6.8

Bestellnummern für SFP-Aufsteckmodule siehe “Bestellnummern/Produktbezeichnung” auf Seite 50. U Drei 10Gigabit ETHERNET-Ports (XFP) beim MACH 4002-24G+3X und MACH 4002-48G+3X Im linken Teil des Basisboards befinden sich drei 10Gigabit ETHERNETPorts (Ports Nummer 5.1 bis 5.3) zum Anschluss von Netzsegmenten. Sie sind als XFP-Schacht ausgeführt.

5.1

5.2

5.3

Folgende XFP-Aufsteckmodule (10Gigabit ETHERNET SFP Transceiver) stehen Ihnen für den MACH 4002-...-3X zur Verfügung: D M-XFP-SR/LC D M-XFP-LR/LC D M-XFP-ER/LC D M-XFP-ZR/LC Bestellnummern für XFP-Aufsteckmodule siehe “Bestellnummern/Produktbezeichnung” auf Seite 50. 1.4.2

Rechter Bereich des Basisboards

U 16 Fast ETHERNET-Ports beim MACH 4002-48+4G Im rechten Teil des Basisboard befinden sich 16 * 10/100BASE-TX-Ports (Ports Nummer 6.1 bis 6.16) zum Anschluss von Netzsegmenten. Die Ports sind als RJ-45 Anschlüsse ausgeführt.

FAULT

6

6.1 6.2

6.3 6.4

MACH 4000 Release

04/08

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

23

U 16 Gigabit ETHERNET-Ports beim MACH 4002-48G und MACH 4002-48G+3X Im rechten Teil des Basisboard befinden sich 16 * 10/100/1000BASETX-Ports (Ports Nummer 6.1 bis 6.16) zum Anschluss von Netzsegmenten. Die Ports sind als RJ-45 Anschlüsse ausgeführt. Beim MACH 4002-48G sind die RJ45-Ports 6.1 bis 6.8 alternativ zu den SFP-Ports 6.1 bis 6.8. im linken Bereich des Basisboards verwendbar (Combo-Ports).

FAULT

6

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

6.9 6.10

6.11 6.12

6.13 6.14

6.15 6.16

FAULT

U Acht Gigabit ETHERNET-Ports beim MACH 4002-24G und MACH 4002-24G+3X Im rechten Teil des Basisboard befinden sich 8 * 10/100/1000BASE-TXPorts (Ports Nummer 6.1 bis 6.8) zum Anschluss von Netzsegmenten. Die Ports sind als RJ-45 Anschlüsse ausgeführt. Beim MACH 4002-24G sind die RJ45-Ports 6.1 bis 6.8 alternativ zu den SFP-Ports 6.1 bis 6.8. im linken Bereich des Basisboards verwendbar (Combo-Ports).

6.1 6.2

1.5

6.3 6.4

6.5 6.6

Medienmodule

M4-8TP-RJ45

24

6.7 6.8

M4-FAST 8TP-RJ45-PoE

MACH 4000 Release

04/08

M4-GIGA 8-SFP

M4-FAST 8-SFP

Abb. 8:

Fast ETHERNET und Gigabit ETHERNET Medienmodule

MACH 4000-Gerät

M4-8TP-RJ45

MACH 4002-48+4G 0 - 4 Module MACH 4002-24G... 0 - 2 Module MACH 4002-48G... 0 - 4 Module

M4-FAST 8TPRJ45-PoE 0 - 4 Module 1) 0 - 2 Module 1) 0 - 4 Module 1)

M4-FAST 8-SFP M4-GIGA 8-SFP 0 - 4 Module 0 - 2 Module 0 - 4 Module

0 Module 0 - 2 Module 0 - 4 Module

Tab. 1: Mögliche Bestückung der MACH 4000-Geräte mit Medienmodulen 1)

Beachten Sie die PoE-Leistungsgrenzen (siehe Abbildung “MACH 4000, Anzahl Ports und Medienmodule” auf Seite 16).

1.5.1

M4-8TP-RJ45

Das Medienmodul M4-8TP-RJ45 bietet Ihnen acht 10/100BASE-TX Ports (RJ-45 Anschlüsse) zum Anschluss von Netzsegmenten. M4-8TP-RJ45

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

P

1.5.2

M4-FAST 8TP-RJ45-PoE

Das Medienmodul M4-8TP-RJ45-PoE bietet Ihnen acht 10/100BASE-TX Ports (RJ-45 Anschlüsse) zum Anschluss von Netzsegmenten. Es unterstützt Power over ETHERNET auf Datenleitungen nach IEEE 802.3af. Die maximale Leistung, die Ihnen für alle Ports zusammen für PoE-Anwendungen zur Verfügung steht, sind in Tabelle “MACH 4000, Anzahl Ports und Medienmodule” auf Seite 16 aufgelistet. Pro Grundgerät können bis zu vier M4-FAST 8TP-RJ45-PoE Module eingesetzt werden. Die Anzahl der Ports, welche PoE-Endgeräte mit Strom versorgen, ist abhängig von der zur Verfügung stehenden Gesamtleistung. Die Stromeinspeisung erfolgt auf die Datenleitungen. Die einzelnen Ports sind zueinander nicht potentialgetrennt.

MACH 4000 Release

04/08

25

M4-FAST 8TP-RJ45-PoE

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

1.5.3

M4-FAST 8-SFP

Das Medienmodul M4-FAST 8-SFP besitzt acht 100BASE-FX Ports (SFPSchächte zur Montage von SFP-Modulen). M4-FAST 8SFP

LS/DA

1

2

1

2

3

3

4

4

5

5

6

6

7

S 7

8

1

4

7

2

5

8

3

6

P

8

Folgende SFP-Aufsteckmodule (Fast ETHERNET SFP Transceiver) stehen Ihnen für das Medienmodul M4-FAST 8-SFP zur Verfügung: D M-FAST SFP-MM/LC D M-FAST SFP-SM/LC D M-FAST SFP-SM+/LC D M-FAST SFP-LH/LC Bestellnummern für SFP-Aufsteckmodule siehe “Bestellnummern/Produktbezeichnung” auf Seite 50. 1.5.4

M4-GIGA 8-SFP

Das Medienmodul M4-GIGA 8-SFP besitzt acht 100/1000BASE-FX Ports (SFP-Schächte zur Montage von SFP-Modulen).

M4-FAST 8SFP

LS/DA

1

2

1

2

3

3

4

4

5

5

6

6

7

S 7

8

1

4

7

2

5

8

3

6

P

8

Folgende SFP-Aufsteckmodule stehen Ihnen für das Medienmodul M4-GIGA 8-SFP zur Verfügung Gigabit ETHERNET SFP Transceiver: D M-SFP-SX/LC D M-SFP-LX/LC D M-SFP-LH+/LC D M-SFP-LH+/LC Fast ETHERNET SFP Transceiver: D M-FAST SFP-MM/LC D M-FAST SFP-SM/LC D M-FAST SFP-SM+/LC D M-FAST SFP-LH/LC Bestellnummern für SFP-Aufsteckmodule siehe “Bestellnummern/Produktbezeichnung” auf Seite 50.

26

MACH 4000 Release

04/08

2

Montage und Inbetriebnahme

Das Gerät ist für die Praxis in der rauhen Industrie-Umgebung entwickelt. Dementsprechend einfach ist die Installation. Das Gerät wird in betriebsbereitem Zustand ausgeliefert. In der Praxis hat sich folgende thematische Reihenfolge bei der Montage des Gerätes bewährt: D Auspacken und Prüfen D Montage der Medienmodule D Montage der SFP/XFP-Module D Montage des Netzteils an der Geräterückseite D Montage der Netzteileinschübe im Netzteil-Grundgerät M4-POWER D Aufstellen oder Montage des Gerätes im 19"-Rack D Erdung des Gerätes D Montage des Netzteil-Grundgerätes, Verbinden mit dem MACH 4000 D Verdrahtung des Meldekontakt-Klemmblockes D Anschluss der Versorgungsspannung, Inbetriebnahme D Montage der Datenleitungen

2.1

Montage des Gerätes

2.1.1

Auspacken und Prüfen

V Überprüfen Sie, ob das Paket komplett bei Ihnen angekommen ist, siehe “Lieferumfang” auf Seite 49. V Überprüfen Sie die Einzelteile auf Transportschäden. 2.1.2

Montage der Medienmodule

Der Switch besitzt vier Einschübe zur Aufnahme von Medienmodulen. Die Anzahl der anschließbaren Netzsegmente hängt von der Anzahl der installierten Medienmodule ab. Bei voller Bestückung mit vier Medienmodulen à 8 Ports erhalten Sie zusätzlich zu den Ports des Basisboards 32 weitere Ports zum Anschluss von Netzsegmenten. Durch den modularen Aufbau des Gerätes können Sie eine Erweiterung des Netzes durch Einbau der gewünschten Medienmodule problemlos selbst durchführen. Die Medienmodule sind während des Netzbetriebes in die Geräte ein- und aussteckbar (hot-swappable).

MACH 4000 Release

04/08

27

Step 1

Step 2

Step 3

V Beachten Sie die “ESD-Hinweise” auf Seite 9“ und die “Sicherheitshinweise” auf Seite 5ff. V Verschließen Sie die gesamte Frontfläche neben den Medienmodulen mit Abdeckblenden. Damit ist eine optimale Abschirmung und Konvektion gegeben. Die Steckplätze für die Medienmodule sind gleichwertig. Sie können beliebig gewählt werden. V Entfernen Sie die Abdeckblende, um das Medienmodul einstecken zu können. V Achten Sie auf die Stellung der blauen Einführgriffe (siehe Abb., Step 1) V Führen Sie das Medienmodul nicht ganz bis zum Anschlag in den ausgewählten Steckplatz ein (siehe Abb., Step 2). V Achten Sie auf eine gute Verbindung der Messerleisten des Medienmoduls mit den Federleisten des Systembusses. V Führen Sie das Medienmodul bis zum Anschlag in den ausgewählten Steckplatz ein, indem Sie die blauen Einführgriffe zudrücken. (siehe Abb., Step 3). V Verschrauben Sie die beiden Rändelschrauben in der Frontblende des Medienmodules mit dem Rahmen des Grundgerätes. 2.1.3

Montage der SFP/XFP-Module

Fast ETHERNET Fiberoptic SFP-Modul

28

Gigabit ETHERNET Fiberoptic SFP-Modul

10Gigabit ETHERNET Fiberoptic XFP-Modul

MACH 4000 Release

04/08

V Vor der Befestigung eines SFP- oder eines XFP-Moduls entfernen Sie zunächst die Schutzkappe des SFP-/XFP-Moduls. V Schieben Sie das SFP-/XFP-Modul mit geschlossener Verriegelung in den Sockel, bis es hörbar einrastet.

Hinweis: Setzen Sie ausschließlich SFP-/XFP-Module von Hirschmann ein. 2.1.4

Montage des Netzteils an der Geräterückseite

V Entfernen Sie die Abdeckblende. V Schieben Sie das Netzteil in den Führungsschienen oben und unten passend bis zum Anschlag in das Grundgerät ein. V Achten Sie auf eine gute Verbindung der Messerleiste des Netzteileinschubs mit der Federleiste des Systembusses. V Verschrauben Sie die vier Schlitzschrauben in der Frontblende des Netzteileinschubs mit dem Rahmen des Grundgerätes. 2.1.5

Montage der Netzteileinschübe im Netzteil-Grundgerät M4-POWER

Tauschen Sie einen defekten Netzteileinschub nur durch einen Netzteileinschub des Typs M4-P-... 300W aus (siehe “Bestellnummern/Produktbezeichnung” auf Seite 50). V Entfernen Sie die Netzspannungszuleitung.

MACH 4000 Release

04/08

29

V Lösen Sie die acht Schrauben zur Befestigung des Netzteileinschubs im Grundgerät und ziehen Sie den Netzteileinschub aus dem Grundgerät heraus bzw. entfernen Sie die Abdeckblende des Netzteilsteckplatzes. V Schieben Sie den neuen Netzteileinschub in den Führungsschienen oben und unten passend bis zum Anschlag in das Grundgerät ein. V Achten Sie auf eine gute Verbindung der Messerleiste des Netzteileinschubs mit der Federleiste des Systembusses. V Verschrauben Sie die Schlitzschrauben in der Frontblende des Netzteileinschubs mit dem Rahmen des Grundgerätes. V Schließen Sie die Netzspannungszuleitung an. Hinweis: Das Anzugsdrehmoment beträgt D 7 lb in. (0,791 Nm) für Eingangsanschlüsse. D 11 lb in. (1,243 Nm) für alle Feldverdrahtungsklemmblöcke. 2.1.6

Aufstellen oder Montage des Switch-Grundgerätes im 19"-Rack

U Aufstellen Verwendung der Grundgeräte als Tischgerät: V Kleben Sie die mitgelieferten Gummifüße an die Unterseite des Gerätes. – Hierzu lösen Sie zuerst die Schutzfolie von der Klebefolie der Gummifüße. – Kleben Sie je einen Gummifuß im Abstand von ca. 2 cm von den Ecken des Gerätes entfernt auf. Hinweis: Die Klebefläche sollte staub- und fettfrei sein. U Einbauen Die Geräte sind für den Einbau in einen 19"-Schrank vorbereitet. V Achten Sie auf ausreichende Belüftung. Sehen Sie eventuell einen Lüfter für den 19" Schrank vor. So vermeiden Sie ein Überhitzen der Grundgeräte. V Bemessen Sie die Tiefe des 19" Schrankes so, dass das Netzkabel und ggf. die Stromversorgungskabel von hinten und die Kabel für die Datenleitungen von vorne zugeführt werden können. Falls Sie das Gerät in einem 19"-Schaltschrank betreiben, sind Gleitschienen/Tragschienen (nicht im Lieferumfang enthalten) zur Aufnahme des Gerätegewichtes zu montieren.

z 30

WARNUNG: Bei Montage im 19"-Schaltschrank ohne Gleitschienen/Tragschienen kann es durch Verstärkung der Vibration zu Schäden am Gerät und/oder dessen Einschüben kommen. MACH 4000 Release

04/08

Für weitere Informationen zu Gleitschienen/Tragschienen und deren Montage wenden Sie sich bitte an Ihren Schaltschrankhersteller. V Montieren Sie die Gleitschienen/Tragschienen, wie vom Hersteller vorgesehen, im 19"-Schaltschrank, und sorgen Sie dafür, dass der MACH 4000 auf beiden Schienen aufliegt.

M4-

AIR

MED 3 1

IA

SLO TS

M4-

SLO 4 T.PO 2 P LED RT P1 RM P2 RL1 P3 L/D RL2 P4 FDX FAN RING POR 1000 RUN T STB Y LED AN TP/F TEST O 2 1

M4-

FAS T 8SF P 1

8TP

-RJ4 5

2

MA

LS

1 MA CH

CH

3 DA LS

4002

2 48+4 G

4 DA LS

3

5 DA LS

4

LED SELEC T

6 DA LS

5

7 DA LS

6

40

8 DA LS

7

1 DA

2 LS

3

8

DA

6.1

LS/D A 4 7 5 8 6 P

M46.2 6.3

FAS T 8SF P

P

1

M4FAS T 8TPRJ45 -PoE

6.4

1

3 DA LS

6.6

2 LS/DA

4 DA LS

6.1

3

6.7

5

Gleitschiene/ Tragschiene

DA LS

RL1

4

FAULT

6.8

00

2 LS

6.5

6 DA LS

5

RL2

7 DA LS

6

8 DA

6.1 6.2

LS

7 6.3 6.4

1 DA

2 LS

8 6.5 6.6

3 DA

LS/D A 4 7 5 8 6 P

6.7 6.8

R

V.24 USB

An den Seiten des Gerätes sind im Lieferzustand zwei Haltewinkel vormontiert (siehe Abbildung unten).

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

MEDIA SLOTS 3 1

4 2 SLOT.PORT

P2

P3

RM

RL1

RL2

FAN

RUN

L/D

P

FDX

P1

1000

AN

TP/FO

2

1

7 8

6

LS/DA

M4-FAST 8SFP

1

2

3

4

5

6

7

8

1

P

M4-FAST 8TP-RJ45-PoE

P4

4

7

2

5

8

3

6

P

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

R

P

MACH 4002 48+4G RING LED PORT STBY TEST

4 5

3 LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-8TP-RJ45

LED

1 2

LS/DA 6.1

LED

RL1

V.24

FAULT

M4-AIR

USB

SELECT RL2

6.1

6.2

6.3

6.4

6.5

6.6

6.7

6.8

6.1 6.2

6.3 6.4

6.5 6.6

6.7 6.8

V Befestigen Sie das Gerät mit den Haltewinkeln durch Verschrauben im Schaltschrank.

z

MACH 4000 Release

04/08

WARNUNG: Achten Sie beim Einbau darauf, dass die Lüftungsschlitze frei bleiben, da es sonst durch Überhitzung zu Schäden am Gerät kommen kann.

31

2.1.7

Erdung des Gerätes

Die Erdung des Gerätes erfolgt über die Stromversorgungsanschlüsse. Hinweis: Die Schirmungsmasse der anschließbaren Twisted-Pair-Leitungen ist elektrisch leitend mit der Frontblende verbunden. Beim Betrieb über das 230/120 VAC-Netzteil ist das Gerät über den SchukoStecker geerdet. Beim Betrieb mit externer DC-Spannung über die M4-POWER-Anschlüsse wird das Gerät über den M4-POWER-Anschluss geerdet. 2.1.8

Montage des Netzteil-Grundgerätes, Verbinden mit dem MACH 4000

V Verbinden Sie Switch-Grundgerät und Netzteil-Grundgerät M4-POWER mit dem im Lieferumfang enthaltenen Montagewinkel. V Zur redundanten Stromversorgung verbinden Sie das/die Netzteil(e) im Netzteil-Grundgerät M4-POWER über das Stromversorgungskabel mit dem M4-POWER-Anschluss an der Geräterückseite des MACH 4000.

z

32

WARNUNG: Die Stromversorgungskabel zwischen dem Netzteil-Grundgerät M4-POWER und dem MACH 4000 sind nicht hot swapable. Beachten Sie die Reihenfolge bei der Verkabelung: Schließen Sie zuerst das/die Stromversorgungskabel zwischen M4-POWER und MACH 4000 an. Schließen Sie danach die Stromversorgung (AC oder DC, je nach Netzteileinschub) für das M4-POWER an.

MACH 4000 Release

04/08

Nicht hot swapable

4 3

M4-S-AC/DC 300W

MACH 4000 Geräterückseite

M4-S-AC/DC 300W

MACH 4000 Geräterückseite

4 3

1 2 3

M4-POWER

Netzteil-Grundgerät M4-POWER Geräterückseite

Step 1: MACH 4000 Gerät(e) an M4-POWER anschließen Netzteileinschub 1 Netzteileinschub 2

nicht bestückt Netzteil-Grundgerät M4-POWER Gerätefront Beispiel: Bestückung mit 2 Netzteileinschüben

Step 2: M4-POWER an Stromversorgung anschließen Redundante Stromversorgung eines oder mehrerer MACH 4000-Geräte über das Netzteil-Grundgerät M4-POWER

2.1.9

Verdrahtung des Meldekontakt-Klemmblockes FAULT

Abb. 9:

RL1

RL2

Abb. 10:

4poliger Meldekontakt

D Der Meldekontakt ("FAULT") dient der Funktionsüberwachung des Gerätes und ermöglicht damit eine Ferndiagnose. Die Art der Funktionsüberwachung können Sie im Management festlegen. D Über das Management können Sie ferner den Meldekontakt manuell schalten und somit externe Geräte steuern. Über den potentialfreien Meldekontakt (Relaiskontakt, Ruhestromschaltung) wird durch Kontaktunterbrechung gemeldet: D der Ausfall mindestens einer Versorgungsspannung. D eine dauerhafte Störung im Gerät. MACH 4000 Release

04/08

33

D der fehlerhafte Linkstatus mindestens eines Ports. Die Meldung des Linkstatus kann pro Port über das Management maskiert werden. Im Lieferzustand erfolgt keine Verbindungsüberwachung. D der Entfall der Redundanzgewährleistung D Fehler beim Selbsttest. Im Stand-by-Modus werden folgende Zustände gemeldet: D Steuerkabel unterbrochen D Steuerkabel kurzgeschlossen D Partnergerät ist im Stand-by-Modus Im Normalmodus werden folgende Zustände gemeldet: D Steuerkabel kurzgeschlossen D Partnergerät ist im Normalmodus Im RM-Betrieb wird zusätzlich folgender Zustand gemeldet: D Ringredundanz gewährleistet. Im Lieferzustand erfolgt keine Überwachung der Ringredundanz V Ziehen Sie den Klemmblock vom Gerät ab und verdrahten Sie die Meldeleitungen. V Montieren Sie den Klemmblock für die beiden Meldekontakte an der Frontseite des Gerätes. Beachten Sie das Einrasten der Rastverriegelung. 2.1.10 Anschluss der Versorgungsspannung, Inbetriebnahme V Die Geräte dürfen nur an die auf dem Typschild aufgedruckten Netzspannung angeschlossen werden. Schließen Sie das Netzkabel an und verbinden dieses mit der Netzspannung. Beachten Sie die Zugentlastung.

z

WARNUNG: Die DC-Module (M4-...-...VDC 300W) sind für den Betrieb mit Sicherheitskleinspannung ausgelegt. Entsprechend dürfen an die Versorgungsspannungsanschlüsse nur PELV-Spannungskreise oder wahlweise SELV-Spannungskreise mit den Spannungsbeschränkungen gemäß IEC/EN 60950-1 angeschlossen werden.

Die externe Versorgungsspannung ist redundant anschließbar (siehe “Spannungsversorgung” auf Seite 18). Beide Eingänge sind entkoppelt. Bei redundanter Einspeisung versorgt das Netzgerät mit der höheren Ausgangsspannung das Gerät alleine. Die Versorgungsspannung ist galvanisch vom

34

MACH 4000 Release

04/08

Gehäuse getrennt. Die Erdung der DC-Module (M4-...-...VDC 300W) erfolgt über einen Anschluss der 3-poligen DC-Buchse. Mit dem Einschalten der Einschubnetzteile nehmen Sie das Gerät in Betrieb. Hinweis: Bei nicht redundanter Zuführung der Versorgungsspannung meldet das Gerät den Ausfall einer Versorgungsspannung. Sie können diese Meldung verhindern, indem Sie die Versorgungsspannung über beide Eingänge zuführen oder die Konfiguration im Management ändern. Hinweis: Die 0V-Anschlüsse innerhalb eines DC-Moduls (M4-...-...VDC 300W) sind miteinander verbunden.

0V

Abb. 11:

+

Steckerbelegung der DC-Buchse (externe Versorgungsspannung)

2.1.11 Montage der Datenleitungen An den Ports des Gerätes können Sie über Twisted-Pair bzw. LWL-Kabel Endgeräte oder weitere Segmente anschließen. U 10/100 Mbit/s-Twisted-Pair-Anschluss 10/100 Mbit/s Ports (RJ45-Buchse) ermöglichen den Anschluss von Endgeräten oder unabhängigen Netzsegmenten nach den Standards IEEE 802.3 100BASE-TX / 10BASE-T. Diese Ports unterstützen: D Autonegotiation D Autopolarity D Autocrossing (bei eingeschaltetem Autonegotiation) D 100 Mbit/s halbduplex, 100 Mbit/s vollduplex, D 10 Mbit/s halbduplex, 10 Mbit/s vollduplex. Lieferzustand: Autonegotiation aktiviert mit Ausnahme der Ringports: 100 Mbit/s vollduplex. Die Gehäuse der Buchsen sind galvanisch mit der Frontblende verbunden.

MACH 4000 Release

04/08

35

n.c. n.c. TDn.c. n.c. TD+ RDRD+

Abb. 12:

Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1

Pinbelegung einer TP/TX-Schnittstelle im MDI-X-Modus, RJ45-Buchse

U 10/100 Mbit/s-Twisted-Pair-Anschluss PoE 10/100 Mbit/s Ports (RJ45-Buchse) ermöglichen den Anschluss von Endgeräten oder unabhängigen Netzsegmenten nach den Standards IEEE 802.3 100BASE-TX / 10BASE-T und IEEE 802.3af (Power over ETHERNET auf Datenleitungen). Diese Ports unterstützen: D Autonegotiation D Autopolarity D Autocrossing (bei eingeschaltetem Autonegotiation) D 100 Mbit/s halbduplex, 100 Mbit/s vollduplex, D 10 Mbit/s halbduplex, 10 Mbit/s vollduplex. D Power over ETHERNET. Die maximale Leistung, die Ihnen für alle Ports zusammen für PoE-Anwendungen zur Verfügung steht, sind in Tabelle “MACH 4000, Anzahl Ports und Medienmodule” auf Seite 16 aufgelistet. Lieferzustand: Autonegotiation aktiviert mit Ausnahme der Ringports: 100 Mbit/s vollduplex. Die Gehäuse der Buchsen sind galvanisch mit der Frontblende verbunden. Die Spannung wird über die signalführenden Adernpaare eingespeist. n.c. n.c. TDn.c. n.c. TD+ RDRD+

Abb. 13:

Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1

Pinbelegung einer TP/TX-Schnittstelle im MDI-X-Modus, RJ45-Buchse

U 10/100/1000 Mbit/s-Twisted-Pair-Anschluss 10/100/1000 Mbit/s Twisted-Pair-Ports (RJ45 Buchse) ermöglichen den Anschluss von Endgeräten oder unabhängigen Netzsegmenten nach dem Standard IEEE 802.3-2000 (ISO/IEC 8802-3:2000) 1000BASE-TX. Diese Ports unterstützen: D Autonegotiation D Autopolarity D Autocrossing (bei eingeschaltetem Autonegotiation) D 1000 Mbit/s vollduplex 36

MACH 4000 Release

04/08

D 100 Mbit/s halbduplex, 100 Mbit/s vollduplex, D 10 Mbit/s halbduplex, 10 Mbit/s vollduplex. Lieferzustand: Autonegotiation. Die Gehäuse der Buchsen sind galvanisch mit der Frontblende verbunden. Die Pinbelegung entspricht MDI-X. BI_DCBI_DC+ BI_DABI_DDBI_DD+ BI_DA+ BI_DBBI_DB+

Abb. 14:

Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1

Pinbelegung der 1000 Mbit/s Twisted-Pair-Schnittstelle

U 100 Mbit/s-LWL-Anschluss 100 Mbit/s-LWL-Ports (SFP-Schacht) ermöglichen den Anschluss von Endgeräten oder unabhängigen Netzsegmenten nach dem Standard IEEE 802.3 100BASE-FX. Diese Ports unterstützen: D Vollduplex Betrieb Lieferzustand: Vollduplex. Hinweis: Stellen Sie sicher, dass Sie LH-Ports nur mit LH-Ports, SMPorts nur mit SM-Ports und MM-Ports nur mit MM-Ports verbinden. U 1 Gbit/s-LWL-Anschluss 1 Gbit/s-LWL-Ports (SFP-Schacht) ermöglichen den Anschluss von Endgeräten oder unabhängigen Netzsegmenten nach dem Standard IEEE 802.3-2000 (ISO/IEC 8802-3:2000) 1000BASE-SX bzw. 1000BASE-LX. Diese Ports unterstützen: D Autonegotiation D Vollduplex Betrieb Lieferzustand: Autonegotiation. Hinweis: Stellen Sie sicher, dass Sie LH-Ports nur mit LH-Ports, SXPorts nur mit SX-Ports und LX-Port mit LX-Ports verbinden. U 10 Gbit/s-LWL-Anschluss 10 Gbit/s-LWL-Ports (XFP-Schacht) ermöglichen den Anschluss von Endgeräten oder unabhängigen Netzsegmenten nach dem Standard IEEE 802.3ae-2002 (ISO/IEC 8802-3:2002) 10GBASE-SR/LR. Diese Ports unterstützen: D Vollduplex Betrieb Lieferzustand: Vollduplex FDX.

MACH 4000 Release

04/08

37

Hinweis: Stellen Sie sicher, dass Sie SR-Ports nur mit SR-Ports, LRPorts nur mit LR-Ports, ER-Ports nur mit ER-Ports und ZR-Ports nur mit ZR-Ports verbinden. V Montieren Sie die Datenleitungen entsprechend Ihrer Anforderungen. 2.1.12 Austauschen des Lüftereinschubs M4-AIR / M4-AIR-T

Der Lüftereinschub ist austauschbar. Der Austausch kann während des Betriebs von einer Elektrofachkraft durchgeführt werden. Abhängig von der Umgebungstemperatur kann das Gerät maximal ein bis zwei Minuten mit ausgebautem Lüftereinschub betrieben werden. U Demontage M4-AIR / M4-AIR-T V Lösen Sie die beiden Schrauben in der Frontblende des Lüftereinschubs M4-AIR / M4-AIR-T. Achtung: Nach dem Ausschalten des Gerätes drehen sich die Lüfterrotoren noch einige Sekunden weiter. Greifen Sie nicht in einen sich drehenden Lüfter! V Ziehen Sie den Lüftereinschub wenige Zentimeter heraus und warten Sie, bis die Lüfter still stehen, bevor Sie ihn ganz herausziehen. U Montage M4-AIR / M4-AIR-T V Demontieren Sie den auszutauschenden Lüftereinschub wie oben beschrieben. V Führen Sie den Lüftereinschub in den Führungsschienen oben und unten passend bis zum Anschlag in das Grundgerät ein. V Achten Sie auf eine gute Verbindung der Messerleiste des Lüftereinschubs mit der Federleiste des Systembusses. V Verschrauben Sie die beiden Rändelschrauben in der Frontblende des Lüftereinschubs mit dem Rahmen des Grundgerätes.

38

MACH 4000 Release

04/08

2.2

Anzeigenelemente

Nach dem Anlegen der Betriebsspannung startet und initialisiert die Software. Danach führt das Gerät einen Selbsttest durch. Während diesen Aktionen leuchten die unterschiedlichen LEDs auf. Die Aktionen dauern knapp 60 Sekunden.

Gerätestatus

LS 1 DA LS 2 DA

M4-8TP-RJ45

LED P

P1

P2

P3

P4

RM

RL1

RL2

FAN

RUN

L/D

FDX

1000

AN

TP/FO

MACH 4002 48+4G

Port-Anzeigestatus

RING LED PORT STBY TEST PoE

LED

1 SELECT

U Gerätestatus Diese LEDs geben Auskunft über Zustände, die Auswirkung auf die Funktion des gesamten Gerätes haben. P- Power (grüne LED) leuchtet grün leuchtet nicht P1 - Power 1 (grüne LED) leuchtet grün leuchtet nicht blinkt grün P2 - Power 2 (grüne LED) leuchtet grün leuchtet nicht blinkt grün P3 - Power 3 (grüne LED) leuchtet grün leuchtet nicht blinkt grün P4 - Power 4 (grüne LED) leuchtet grün leuchtet nicht blinkt grün

MACH 4000 Release

04/08

Bedeutung Interne Versorgungsspannung liegt an Interne Versorgungsspannung ist zu niedrig Bedeutung Versorgungsspannung 1 am Netzteileinschub liegt an Versorgungsspannung 1 am Netzteileinschub liegt nicht an oder ist zu niedrig Versorgungsspannung 1 liegt an, aber Netzteileinschub meldet einen Fehler Bedeutung Versorgungsspannung 2 am Netzteileinschub liegt an Versorgungsspannung 2 am Netzteileinschub liegt nicht an oder ist zu niedrig Versorgungsspannung 2 liegt an, aber Netzteileinschub meldet einen Fehler Bedeutung Versorgungsspannung 3 am externen Eingang 3 liegt an Versorgungsspannung 3 am externen Eingang 3 liegt nicht an oder ist zu niedrig Versorgungsspannung 3 liegt an, aber Netzteileinschub meldet einen Fehler Bedeutung Versorgungsspannung 4 am externen Eingang 4 liegt an Versorgungsspannung 4 am externen Eingang 4 liegt nicht an oder ist zu niedrig Versorgungsspannung 4 liegt an, aber Netzteileinschub meldet einen Fehler

39

RM - Redundanz Manager (grün/gelbe LED) leuchtet grün leuchtet gelb leuchtet nicht blinkt grün RL1 - Relay 1, Meldekontakt (rot/gelbe LED) leuchtet rot leuchtet gelb leuchtet nicht

RL2 - Relay 2, Meldekontakt (rot/gelbe LED) leuchtet rot leuchtet gelb leuchtet nicht

FAN - Lüfter-Sammelstatus (grün/gelbe LED) leuchtet grün leuchtet gelb

RUN - BOOT/RUN (grün/gelbe LED) leuchtet grün blinkt grün leuchtet nicht

Bedeutung RM-Funktion aktiv, redundanter Port nicht aktiv RM-Funktion aktiv, redundanter Port aktiv RM-Funktion nicht aktiv Fehlkonfiguration des HIPER-Rings (z.B. Ring nicht an Ringport angeschlossen. Bedeutung Der Meldekontakt 1 ist offen, d.h. er meldet einen Fehler. Der Meldekontakt 1 ist offen, die „Manuelle Einstellung“ ist aktiv Der Meldekontakt 1 ist geschlossen, d.h. er meldet keinen Fehler oder wurde über die „Manuelle Einstellung“ geschlossen. Bedeutung Der Meldekontakt 2 ist offen, d.h. er meldet einen Fehler. Der Meldekontakt 2 ist offen, die „Manuelle Einstellung“ ist aktiv Der Meldekontakt 2 ist geschlossen, d.h. er meldet keinen Fehler oder wurde über die „Manuelle Einstellung“ geschlossen. Bedeutung Der Lüftereinschub ist vorhanden und kein Lüfter meldet einen Fehler. Der Lüftereinschub ist vorhanden und mindestens ein Lüfter meldet einen Fehler oder der Lüftereinschub ist nicht vorhanden. Bedeutung System ist betriebsbereit System bootet System ist im Reset-Zustand

U Port-Anzeigestatus Jedes Medienmodul verfügt über eine LED je Port. Die Bedeutung dieser Portstatus-LEDs ist abhängig von der Einstellung am Grundgerät. Mit dem Taster „SELECT“ am Grundgerät legen Sie die Anzeigebedeutung fest. V Drücken Sie den Taster ca. 2 Sekunden lang, um die Bedeutung weiter zu schalten. Bleibt die Taste ca. 20 Sekunden unbetätigt, dann wechselt der Anzeigestatus zurück auf „L/D“. L/D - Daten, Linkstatus (grüne LED) leuchtet grün

40

Bedeutung Die Port-LEDs der Medienmodule zeigen den Verbindungsstatus an. MACH 4000 Release

04/08

FDX - Vollduplex (grüne LED) leuchtet grün 1000 - 10/100/1000 Mbit/s (grüne LED) leuchtet grün

Bedeutung Die Port-LEDs der Medienmodule zeigen die Verbindungsart voll- oder halbduplex an. Bedeutung Die Port-LEDs der Medienmodule zeigen die eingestellte Übertragungsgeschwindigkeit.

AN - Autonegotiation (grüne LED) leuchtet grün

Bedeutung

RING PORT - Ringport (grüne LED) leuchtet grün

Bedeutung

STBY - Stand by (grüne LED) leuchtet grün

Die Port-LEDs der Medienmodule zeigen die Portkonfigurationsart an.

Die Port-LEDs der Medienmodule zeigen die Zugehörigkeit zum HIPER-Ring an. Bedeutung Die Port-LEDs der Medienmodule zeigen die Zugehörigkeit zu einer redundanten Kopplung von Netzsegmenten an.

LED TEST - Leuchtdiodentest Bedeutung (grüne LED) leuchtet grün Der Test der Status-, Anzeigestatus- und PortstatusLEDs ist aktiv. Die Status LED „RM“ blinkt grün/gelb. Die Status LED "FAULT" blinkt rot. Die Anzeigestatus-LEDs blinken grün. Die Portstatus-LEDs der Medienmodule blinken grün/ gelb. TP/FO - Twisted Pair / Fiber Bedeutung Optic (grüne LED) leuchtet grün Die Port-LEDs der Medienmodule zeigen die Medienart an. Alle Anzeigestatus-LEDs Bedeutung (grüne LEDs) Lauflicht Initialisierungsphase nach Neustart 1 (grüne LED) Bedeutung Service-LED PoE oder 2 (grüne LED) Bedeutung leuchtet grün Die Port-LEDs der Medienmodule zeigen den PoEStatus an (Power over Ethernet).

U AutoConfiguration Adapter ACA RUN, 1 - Speicheroperationen des AutoConfiguration Adapter ACA anzeigen blinken alternativ: LEDs blinken synchron; 2 mal pro Sekunde LEDs blinken synchron; 1 mal pro Sekunde

MACH 4000 Release

04/08

Bedeutung Fehler bei der Speicheroperation. Laden der Konfiguration vom ACA. Speichern der Konfiguration in den ACA.

41

U Portstatus LS/DA

8

1

4

7

2

5

8

3

6

M4-FAST 8SFP

1

2

3

4

5

6

7

8

P

8 DA

LS 1 DA LS 2 DA LS 3 DA LS 4 DA LS 5 DA LS 6 DA LS 7 DA LS 8 DA

M4-FAST 8TP-RJ45-PoE

P

LS/DA 6.1

V

FAULT

RL1

6.16

RL2 LS

DA

LS

DA

61

63

65

67

69

6 11

6 13

6 15

Diese LEDs zeigen portbezogene Informationen an. Pro Port stehen D zwei einfarbige LEDs oder D eine zweifarbige LED zur Verfügung. Den Inhalt der Information stellen Sie mit dem Taster am Grundgerät ein (siehe “Port-Anzeigestatus” auf Seite 40). 1 bis n - Daten, Linkstatus (grün/gelbe LED) leuchtet nicht leuchtet grün blinkt grün (1 Mal pro Periode) blinkt grün (3 Mal pro Periode) blitzt gelb 1 bis n - FDX (grün/gelbe LED) leuchtet nicht leuchtet grün 1 bis n – 1000 (grün/gelbe LED) leuchtet nicht leuchtet grün leuchtet gelb blinkt grün/gelb 1 bis n – AUTONEG (grün/gelbe LED) leuchtet grün 1 bis n – TP/FO Twisted Pair / Fiber Optic (grün/gelbe LED) leuchtet gelb leuchtet grün leuchtet nicht

42

Bedeutung keine gültige Verbindung. gültige Verbindung. Port ist auf Stand-by geschaltet (Port 1). Port ist ausgeschaltet. Datenempfang. Bedeutung Halbduplex ist aktiv. Vollduplex ist aktiv. Bedeutung 10 Mbit/s ist aktiv. 100 Mbit/s ist aktiv. 1000 Mbit/s ist aktiv. 10000 Mbit/s ist aktiv. Bedeutung Autonegotiation ist aktiv. Bedeutung Fiber Optic wurde ausgewählt. Die Port-LEDs der Medienmodule zeigen LWL-Ports an. Twisted Pair wurde ausgewählt. Die Port-LEDs der Medienmodule zeigen Twisted-Pair-Ports an. Autoselect, kein Medium ist ausgewählt

MACH 4000 Release

04/08

1 bis n – RING PORT (grün/gelbe LED) leuchtet grün 1 bis n – STAND-BY (grün/gelbe LED) leuchtet grün leuchtet gelb blinkt grün/gelb 1 bis n – LED TEST (grün/gelbe LED) leuchtet nicht blinkt grün/gelb 1 bis n – PoE (grün/gelbe LED) leuchtet grün leuchtet gelb leuchtet nicht

2.3

Bedeutung Dieser Port gehört zum HIPER-Ring. Bedeutung Anschluss-Port für die Datenleitung. Anschluss-Port für die Steuerleitung. kein Stand-by-Partner vorhanden. Bedeutung LED defekt. LED Test ist aktiv. Bedeutung Ein PoE-Endgerät hat sich angemeldet und erhält Spannung über PoE. Power over ETHERNET Funktion aktiviert, aber es wird keine Spannung über PoE geliefert. Kein PoE-Port oder: Power over ETHERNET Funktion deaktiviert (PoE Portstatus = Disabled).

Grundeinstellungen vornehmen

Bei der Erstinstallation des Gerätes ist die Eingabe von IP-Parametern notwendig. Das Gerät bietet 6 Möglichkeiten zur Konfiguration der IP-Adressen: D D D D D D

Eingabe über den V.24-Anschluss Eingabe mit Hilfe des HiDiscovery Protokolls Konfiguration über BOOTP Konfiguration über DHCP Konfiguration über DHCP Option 82 AutoConfiguration Adapter

U Lieferzustand D IP-Adresse: Gerät sucht IP-Adresse über DHCP D Password für Management: Login: user, Paßwort: public (nur Leserecht) Login: admin, Paßwort: private (Lese- und Schreibrecht) D V.24-Datenrate: 9.600 Baud D Ringredundanz: ausgeschaltet D ETHERNET-Ports: Linkstatus wird nicht ausgewertet (Meldekontakt) D Optische 100 Mbit/s-Ports: 100 Mbit/s Fullduplex Optische 10 Gbit/s-Ports: 10 Gbit/s Fullduplex Alle anderen Ports: Autonegotiation D Redundanz Manager ausgeschaltet D Stand-by-Kopplung ausgeschaltet MACH 4000 Release

04/08

43

U USB-Schnittstelle An der USB-Buchse steht eine Schnittstelle für den lokalen Anschluss eines AutoConfiguration Adapters ACA 21-USB zur Verfügung. Er dient zum Speichern/Laden der Konfiguration und zum Laden der Software. Kontaktnummer 1 2 3 4

Signalname VCC - Data + Data Ground

U V.24-Schnittstelle (externes Management) An der RJ11-Buchse (V.24-Schnittstelle) steht eine serielle Schnittstelle für den lokalen Anschluss einer externen Managementstation (VT100Terminal oder PC mit entsprechender Terminalemulation) zur Verfügung. Damit kann eine Verbindung zum Command Line Interface CLI und zum Systemmonitor hergestellt werden. Einstellungen VT 100-Terminal Speed Data Stopbit Handshake Parity

9.600 Baud 8 bit 1 bit off none

Das Gehäuse der Anschlussbuchse ist galvanisch mit der Frontblende des Gerätes verbunden. Die V.24 Schnittstelle besitzt keine galvanische Trennung von der Versorgungssannung. RJ11 Pin 6

DB9 Pin 5 Pin 8

Pin 1

CTS n.c. TX GND RX RTS

1 2 3 4 5 6

2 3 5

Pin 1

Abb. 15:

Pinbelegung der V.24-Schnittstelle

Hinweis: Die Bestellnummer für das separat zu bestellende Terminalkabel finden Sie im Kapitel “Technische Daten” auf Seite 46 ff. Eine ausführliche Beschreibung zur Konfiguration finden Sie im „Anwender-Handbuch Grundkonfiguration“ auf der CD-ROM.

44

MACH 4000 Release

04/08

2.4

Demontage

2.4.1

Demontage der Medienmodule

Step 1

Step 2

Step 3

V Beachten Sie die “ESD-Hinweise” auf Seite 9“ und die “Sicherheitshinweise” auf Seite 5ff. V Hebeln Sie das ausgewählte Medienmodul aus dem Steckplatz, in dem Sie die blauen Einführgriffe ziehen (siehe Abb., Step 1 und 2). V Ziehen Sie das Medienmodul aus dem Steckplatz (siehe Abb., Step 3). V Verschließen Sie den Steckplatz mit einer Abdeckblende. V Verschrauben Sie die vier Rändelschrauben der Abdeckblende mit dem Rahmen des Grundgerätes. 2.4.2

Demontage der SFP/XFP-Module

V Ziehen Sie das SFP/XFP-Modul an der geöffneten Verriegelung aus dem Sockel heraus. V Verschließen Sie das SFP/XFP-Modul mit der Schutzkappe.

MACH 4000 Release

04/08

45

3

Technische Daten

Allgemeine technische Daten Abmessungen Montage Masse Stromversorgung

MACH 4002-... M4-POWER MACH 4002-... M4-POWER MACH 4002-... MACH 4002-...

Betriebsspannung M4-S-AC/DC 300W M4-S-24VDC 300W M4-S-48VDC 300W M4-P-AC/DC 300W M4-P-24VDC 300W M4-P-48VDC 300W Pufferzeit M4-P-AC/DC 300W M4-...-24VDC 300W M4-...-48VDC 300W Stromaufnahme M4-S-AC/DC 300W M4-S-24VDC 300W M4-S-48VDC 300W M4-P-AC/DC 300W M4-P-24VDC 300W M4-P-48VDC 300W Einschaltstrom M4-S-AC/DC 300W M4-P-AC/DC 300W Überstromschutz am Eingang Potentialdifferenz M4-...-...VDC 300W zwischen Eingangsspannung und Gehäuse Umgebung Lagerungstemperatur Luftfeuchtigkeit Luftdruck Betriebstemperatur MACH 4002-... M4-S-xx, M4-P-xx M-SFP-xx/xx M-XFP-xx/xx M-FAST SFP-xx/xx M4-AIR / M4-AIR-T M4-8TP-RJ45 M4-8TP-RJ45 PoE M4-FAST 8-SFP M4-GIGA 8-SFP Verschmutzungsgrad Schutzklassen Laserschutz Schutzklasse

46

B x H x T: 480 mm x 88 mm x 435 mm B x H x T: 480 mm x 88 mm x 435 mm 19"-Schaltschrank 19"-Schaltschrank 7,5 kg Netzteil M4-S-xx oder Netzteil-Grundgerät M4-POWER mit Netzteil M4-P-xx, bitte separat bestellen 100-240 VAC +/- 10% 24 VDC (19,2 V - 32 V) 1) 48 VDC (38,4 V - 60 V) 1) 100-240 VAC +/- 10% 24 VDC (19,2 V - 32 V) 1) 48 VDC (38,4 V - 60 V) 1) min. 1/2 Netzperiode min. 10 ms bei 20,4 VDC min. 10 ms bei 40,8 VDC max. 1,7 A (240 VAC), max. 4,0 A (100 VAC) max. 16,0 A (24 VDC), max. 20 A (19,2 - 32 VDC) max. 8,0 A (48 VDC), max. 10 A (38,4 - 60 VDC) max. 1,7 A (240 VAC), max. 4,0 A (100 VAC) max. 16,0 A (24 VDC), max. 20 A (19,2 - 32 VDC) max. 8,0 A (48 VDC), max. 10 A (38,4 - 60 VDC) typ.

Suggest Documents