Install T8 Tube Lights in T5 holder's

NEW T8 Tube Light for T5 holder --can replace T5 Tube Light Ideal for decorative and ambient lighting in retail outlets, hotels, restaurants, governm...
Author: Jesse Ramsey
5 downloads 0 Views 911KB Size
NEW T8 Tube Light for T5 holder --can replace T5 Tube Light

Ideal for decorative and ambient lighting in retail outlets, hotels, restaurants, government buildings, warehouses and multiunit residences

Install T8 Tube Lights in T5 holder's • More high-watt Tube Lights can be used—21-23W •More brightness than T5 Tube Light •More heat-dissipating than T5 Tube Light •Lower lumen depreciation Germany Patent: Gebrauchsmusters / Nr. 20 2011 052 005.6 Japan Patent: Registration Number: 3173203 High efficacy accent light *

• 50,000-hour rated average life • Superior color rendering with 80CRI • Instant-on light • Emits virtually no UV/IR light in the beam • Contains no mercury • Unsurpassed light uniformity Easy to experience • Offers omni-directional light for ambient illumination • 5 years limited warranty

T8 Tube Light Product specification (Subject to change without notice) Item Number

Power (watts)

Dimension

Light source

LT-T512-21WE09

21W

Dia.26 x 1170mm

SMD2835*144pcs

G13

LT-T512-23WE09

23W

Dia.26 x 1170mm

SMD2835*144pcs

G13

Light base

Certification

Warranty

UL, cUL, DLC in Pending UL, cUL, DLC in Pending

5 years 5 years

Electrical and Technical Data (Subject to change without notice) Item Number

Power (watts)

LT-T512-21WE09

21W

LT-T512-23WE09

23W

Input

View

Input Voltage

Frequency

Angle

PF

100-277V

50-60Hz

120°

>0.99

100-277V

50-60Hz

120°

CRI

2500lm-clear cover

2570lm-clear cover

Min.80

4000-6000

2650lm-clear cover

2770lm-clear cover

Min.80

4000-6000

Approx. Lumens @4000K

50,000 50,000

>0.99

Approx. Lumens @5000K, 6000K

Rated Avg. Life (Hours)

Color Temp. (Kelvin)

Shipping Data (Subject to change without notice) Inner box Dimensions (L x W x H) (mm)

Item Number LT-T812-21WE09 LT-T812-23WE09

Carton Dimensions (L x W x H) (mm.)

1230 x 45 x 45 1230 x 45 x 45

Qty. of Per Carton

Per Carton Gross Weight (KG)

1250 x 215 x 220

25pcs

18.0

1250 x 215 x 220

25pcs

18.0

Approx. Qty. of per 20 container (pcs.)

LT-T812-21W(23w)E09 Size Diagram

A: 1149mm B: 1157mm C: 1165mm

D: 26mm E: 31mm

F: 16mm G: 5mm

Size Diagram comparison between original T8 ends and T5 ends T8 ends

T5 ends

5.0

Photometry: LT-T812-21WE09

Approx. Qty. of per 40 container (pcs.)

Quick Installation Guide T8 Tube Light Energy Saving Data Energy Effciency, Reducing carbon dioxide emissions Estimated Lighting Costs Using a 36W Fluorescent Lamp Present Wattage x Annual Operating Hours .

.

. ÷1,000 x kWh rate of $0.11 x 100 lamps per space

.

= = = =

.

.

40 W 3,000 hrs 120,000 watt-hours

120 $ 13.2 $ 1320

kWh per year per year annual energy cost per space

Estimated Lighting Costs Using a 21W T8 Tube Light Present Wattage x Annual Operating Hours .

21

. ÷1,000 x kWh rate of $0.11 x 100 lamps per space

.

=

.

= = = .

Total Estimated Annual Savings

Reducing carbon dioxide emissions:

3,000 63,000 63 $6.93 $693

W hrs watt-hours kWh per year per year annual energy cost per space

. =

$627

8 ton CO2 /year

Based on 100 lamps per space operating at 3,000 hours per year.

This energy saving example shows an application of 100 tubes in a space currently using 100 incandescent 36W, operating 3,000 hours per year at a cost of $0.11 per kWh. Your actual savings may vary depending on the energy costs in your geographic location. Replacing 100 standard incandescent 36W fluorescent tubes with the 18W T8 Tube Lights can provide significant energy cost savings of $627 per year! Potential savings from the reduction savings from the reduction in HVAC costs as a result of using a lower wattage bulb that emits less heat is an additional benefit not included in this example.

Instructions Please take the time to read this quick installation guide. The guide contains important information and notes regarding the installation and operation of The T8 Tube Light Specifier Series. •T8 Tube Light Specifier Series are suitable to replace either. During replacement, rewiring is necessary, please follow the installation steps. Traditional fluorescent tube wiring diagram

VS

LED tube wiring diagram (Retrofit is MUST)

Replace Instructions

• Retrofit Luminaire with One Tube

1. Remove diffuser (if applicable) and fluorescent tube. 2. Retrofit all wires which are connected to the ballast.

VS

3. Install this Tube Light directly. 4. Repeat steps 1 to 3 for each additional bulb\ ballast based on illustration below.

• Retrofit Luminaire with Two Tubes and one ballast

Luminare Description 1. This LED tube is suitable to be installed in T8 standard luminaries. 2. Ensure all parts and accessories are in the package, included instruction, filed- applied label and tubular LED lamp. 3. Please make sure the existed luminaire dimension is large enough to replace This LED tubes.

VS

• Retrofit Luminaire with Three/Four Tubes and one ballast

V S

• Retrofit Luminaire with Three/Four Tubes and two ballasts

V S

Note: All wires must be joined by insulated tape and terminal block as following, Accessibility of a live part is prohibited.

Only a qualified electrician is permitted to install this Tube Light.

Packing

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS WARNING: “THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.”

1. Risk of fire or electric shock. The electrical rating of these products are 100~277V, the installer must determine whether they have 100~277V at the luminaire before installation. 2. Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when installing of reflector kit hardware. Check for enclosed wiring and components. 3. Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. 4. Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. 5. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. 6. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation DANGER-RISK OF SHOCK-DISCONNECT POWER BEFORE INSTALLATION. CAUTIONS: 1. Suitable for dry and damp locations. 2. Do not use with Dimmers. 3. Not for use in totally enclosed luminaires. 4. This device is not intended for use with emergency exit fixtures or emergency lights. 5. Before replacing, turn off power and let lamp cool to avoid electrical shock or burn. 6. Risk of electric shock. Do not use where directly exposed to water. 7. This device is not intended for use with emergency exits. 8. Lamps must be operated within an ambient fixture temperature of -22F (-30c) and 113F (45c) co comply with all safety and warranty regulations.

Light and Energy International, LLC, P.O. Box 51960, Sparks, NV 89434 USA

Suggest Documents