Inspection Report. Bob Doe. Precise Home Inspections LLC. Property Address: Beach Blvd. Orange Beach Al Inspected Property

Precise Home Inspections LLC Doe Inspection Report Bob Doe Property Address: 14376 Beach Blvd Orange Beach Al 36561 Inspected Property Unit Entry ...
Author: Camilla Watts
4 downloads 0 Views 1MB Size
Precise Home Inspections LLC

Doe

Inspection Report Bob Doe Property Address: 14376 Beach Blvd Orange Beach Al 36561

Inspected Property

Unit Entry Door

Precise Home Inspections LLC

14376 Beach Blvd

Page 1 of 37

Precise Home Inspections LLC

Doe Brad Robbins HI# 4044 8810 Lea Brook St Fairhope, AL 36532 251-680-3291

14376 Beach Blvd

Page 2 of 37

Precise Home Inspections LLC

Doe

Table of Contents Cover Page Table of Contents Intro Page 1 Exterior 2(A) Living Room 2(B) Laundry Room 2(C) Bedrooms 2(D) Bathrooms 3 Kitchen Components and Appliances 4 Plumbing System 5 Electrical System 6 Heating / Central Air Conditioning General Summary Invoice Attachments Agreement

14376 Beach Blvd

Page 3 of 37

Precise Home Inspections LLC

Doe

Date: 1/30/2015

Time: 12:00 PM

Report ID: 316

Property: 14376 Beach Blvd Orange Beach Al 36561

Customer: Bob Doe

Real Estate Professional: Nate Duhe Keller Williams

Comment Key or Definitions The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property. Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear. Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. Not Present (NP) = This item, component or unit is not in this home or building. Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. This condominium inspection is a partial inspection and is performed on only those components that the buyer or homeowner is responsible for. It does not include the exterior components of the property, crawlspace or attic and all of the components contained therein as this is usually owned by the association and is not owned by the buyer or home owner. It is up to the buyer to determine if any of these excluded areas are in fact the buyers responsibility and if so, to notify the inspector so these areas will be inspected. Please note a different charge will apply should the buyer want these areas inspected. It also is not possible in some cases to inspect attic areas where a duplex unit exist and the buyer is purchasing the lower unit, or vice versa. Our company makes no representation as to the condition of these areas that were not inspected. In Attendance: Standards of Practice: NACHI National Association of Certified Vacant (inspector only) Home Inspectors

Type of building: Condominium

Approximate age of building: 10 years old

Temperature: Below 65

Weather: Clear

Ground/Soil surface condition: Dry

Rain in last 3 days: No

14376 Beach Blvd

Page 4 of 37

Precise Home Inspections LLC

Doe

1. Exterior The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.

Balcony Overview

Styles & Materials Siding Style: EIFS

Exterior Entry Doors: Sliding IN

1.0 Doors



1.1 Windows



1.2 Decks, Balconies, Porches, Patios, Stops, Railings



1.3 Outlets, Fixtures,Electrical (Exterior)



IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

IN

NI NP RR

NI NP RR

The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 5 of 37

Precise Home Inspections LLC

Doe

2(A) . Living Room The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Living Room Overview

Styles & Materials Ceiling Materials:

Wall Material:

Drywall

Drywall

Floor Covering(s): Tile

Interior Doors: Wood Sliding Door (Exterior) IN

NI NP RR

2.0.A Ceilings



2.1.A Walls



2.2.A Floors



2.3.A Doors (Representative number)



2.4.A Windows (Representative number)



2.5.A Outlets, Switches and Fixtures



IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

14376 Beach Blvd

IN

NI NP RR

Page 6 of 37

Precise Home Inspections LLC

Doe

2.0.A The Sheetrock on the ceiling has stress cracks present in the Living Room. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.A Item 1(Picture) Ceiling stress cracks present 2.1.A There are water streaks on a wall (right facing wall). This is from condensation build up on the aluminum air register. This is cosmetic damage. Repair as needed.

2.1.A Item 2(Picture) Air register above water streaks 2.1.A Item 1(Picture) Water streaks present The interior of the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 7 of 37

Precise Home Inspections LLC

Doe

2(B) . Laundry Room The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Laundry Room Overview

Styles & Materials Ceiling Materials: Drywall

Interior Doors: Wood

Wall Material: Drywall

Floor Covering(s): Tile

Clothes Dryer Vent Material: Flexible Metal IN

2.0.B Ceilings



2.1.B Walls



2.2.B Floors



2.3.B Doors (Representative number)



2.4.B Outlets, Switches and Fixtures



2.5.B Clothes Dryer Vent Piping



2.6.B Hot and Cold water supply lines



IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

IN

NI NP RR

NI NP RR

The interior of the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 8 of 37

Precise Home Inspections LLC

Doe

2(C) . Bedrooms The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Front Left Bedroom Overview

Left Middle Bedroom Overview

Master Bedroom Overview

Styles & Materials Ceiling Materials: Drywall

Interior Doors: Wood

Wall Material: Drywall

Floor Covering(s): Tile

Window Types: Aluminum IN

NI NP RR

2.0.C Ceilings



2.1.C Walls



2.2.C Floors



2.3.C Doors (Representative number)



2.4.C Windows (Representative number) 2.5.C Outlets, Switches and Fixtures IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

14376 Beach Blvd

• • IN

NI NP RR

Page 9 of 37

Precise Home Inspections LLC

Doe

2.0.C (1) The Sheetrock on the ceiling has stress cracks present in the Front Left Bedroom. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.C Item 1(Picture) Ceiling stress cracks present in Front Left bedroom 2.0.C (2) The Sheetrock on the ceiling has stress cracks present in the Left Middle Bedroom. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.C Item 2(Picture) Ceiling stress cracks present in Left Middle Bedroom

14376 Beach Blvd

Page 10 of 37

Precise Home Inspections LLC

Doe

2.0.C (3) The Sheetrock on the ceiling has stress cracks present in the Master Bedroom. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.C Item 3(Picture) Ceiling stress cracks present in Master Bedroom 2.1.C There is a hole in the wall in the Left Middle Bedroom. This is from the entry door knob striking the wall. This is cosmetic damage. Repair as necessary using a qualified person.

2.1.C Item 1(Picture) Damaged wall at Left Middle Bedroom

14376 Beach Blvd

Page 11 of 37

Precise Home Inspections LLC

Doe

2.4.C Could not open the window in the Left Middle Bedroom. Repair or replace as necessary using a qualified person.

2.4.C Item 1(Picture) Could not open the window Left Middle Bedroom The interior of the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 12 of 37

Precise Home Inspections LLC

Doe

2(D) . Bathrooms The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Master Bathroom Overview

Hall Bathroom Overview

Styles & Materials Ceiling Materials: Drywall

Interior Doors: Wood

Wall Material: Drywall

Cabinetry: Wood

Floor Covering(s): Tile

Countertops: Cultered Marble IN

2.0.D

Ceilings

2.1.D

Walls



2.2.D

Floors



2.3.D

Doors (Representative number)



2.4.D

Outlets, Switches and Fixtures



2.5.D

Counters and a represnetative number of cabinets



2.6.D

Plumbing Drain and Vent Systems

2.7.D

Plumbing Water Supply Faucets and Fixtures



2.8.D

Exhaust Fans



2.9.D

Toilet







2.10.D Shower Surround IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

14376 Beach Blvd

NI NP RR

• IN

NI NP RR

Page 13 of 37

Precise Home Inspections LLC

Doe

2.0.D The Sheetrock on the ceiling has stress cracks present in the Master Bathroom. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.D Item 1(Picture) Ceiling stress crack at Master Bathroom 2.6.D Slow tub drain in the Hall Bathroom. Possible clog. Repair as needed using a qualified person.

2.6.D Item 1(Picture) Slow tub drain in the Hall Bathroom

14376 Beach Blvd

Page 14 of 37

Precise Home Inspections LLC

Doe

2.10.D (1) Tile grout cracking at Master Bathroom shower surround. Repair as needed using a qualified person.

2.10.D Item 1(Picture) Tile grout cracking at Master Bathroom 2.10.D (2) Shower surround tile is not flush in Hall Bathroom. The tile is secure to the wall. Repair as needed using a qualified person.

2.10.D Item 2(Picture) Shower surround tile not flush in Hall Bathroom The interior of the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 15 of 37

Precise Home Inspections LLC

Doe

3. Kitchen Components and Appliances The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.The home inspector shall

observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.

Kitchen Overview

Styles & Materials Ceiling Material: Drywall

Dishwasher Brand: GENERAL ELECTRIC

Built in Microwave: GENERAL ELECTRIC

Wall Materials: Drywall

Disposer Brand: BADGER

Refrigerator: General Electric

Floor Materials: Tile

Range/Oven: GENERAL ELECTRIC

Cabinetry: Wood

Countertop: Granite

14376 Beach Blvd

Page 16 of 37

Precise Home Inspections LLC

Doe IN

NI NP RR

3.0

Ceilings



3.1

Walls



3.2

Floors



3.3

Pantry/Closet Doors



3.4

Counters and a Representative Number of Cabinets



3.5

Plumbing Drain and Vent Systems



3.6

Plumbing Water Supply Faucets and Fixtures



3.7

Outlets, Wall Switches and Fixtures



3.8

Dishwasher



3.9

Ranges/Ovens/Cooktops



3.10 Food Waste Disposer 3.11 Microwave Cooking Equipment 3.12 Refrigerator IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

• • • IN

NI NP RR

3.0 The Sheetrock on the ceiling has stress cracks present in the Kitchen. This damage is considered cosmetic. A qualified person should repair as needed.

3.0 Item 1(Picture) Ceiling stress crack present

14376 Beach Blvd

Page 17 of 37

Precise Home Inspections LLC

Doe

3.1 The Sheetrock on the wall has a stress crack present in the Kitchen (above the Bar). This damage is considered cosmetic. A qualified person should repair as needed.

3.1 Item 1(Picture) Wall has stress crack present 3.10 The food disposer would not operate or is non functional. I recommend repair or replace as needed using a qualified person.

3.10 Item 1(Picture) Waste disposal not working The interior of the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. The built-in appliances of the home were inspected and

reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 18 of 37

Precise Home Inspections LLC

Doe

4. Plumbing System The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.

Hot water heater product information decal

Hot water heater overview

Styles & Materials Water Source: Public

Plumbing Water Distribution (inside condo):

Plumbing Waste Line: PVC

PEX

Water Heater Power Source:

Water Heater Capacity: 38 Gallons

Electric

Water Heater Location: Closet (adjacent to Kitchen)

Water Heater Manufacturer: RICHMOND

Water Heater Age: 3 years old IN

4.0 Plumbing Drain, Waste and Vent Systems



4.1 Plumbing Water Supply and Distribution Systems and Fixtures



4.2 Hot Water Systems, Controls, Chimneys, Flues and Vents



4.3 Water Shut-off Device IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

14376 Beach Blvd

NI NP RR

• IN

NI NP RR

Page 19 of 37

Precise Home Inspections LLC

Doe

The plumbing in the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 20 of 37

Precise Home Inspections LLC

Doe

5. Electrical System The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.

Condo electrical panel

Condo electrical panel wiring

Styles & Materials Electrical Service Conductors: Below ground

Electric Panel Manufacturer: GENERAL ELECTRIC

Panel capacity: 200 AMP

Branch wire 15 and 20 AMP: Copper

Panel Type: Circuit breakers

Wiring Methods: Romex

Dryer Power Source: 220 Electric

14376 Beach Blvd

Page 21 of 37

Precise Home Inspections LLC

Doe IN

5.0

Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels



5.1

Branch Circuit Conductors, Overcurrent Devices and Compatibilty of their Amperage and Voltage



Connected Devices and Fixtures (Observed from a representative number 5.2 operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)



Polarity and Grounding of Receptacles Within 6 Feet of Interior Plumbing 5.3 Fixtures, and All Receptacles in Garage, Carport, Exterior Walls of Inspected Structure



5.4 Location of Main and Distribution Panels



5.5 Smoke Detectors



5.6 Carbon Monoxide Detectors IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

NI NP RR

• IN

NI NP RR

5.4 The condo unit main panel is located to the right of the unit entry door. The electrical system of the condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 22 of 37

Precise Home Inspections LLC

Doe

6. Heating / Central Air Conditioning The home inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to home; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms.

14376 Beach Blvd

Page 23 of 37

Precise Home Inspections LLC

Doe

Roof Mount AC unit

Roof Mount AC unit product information decal

Interior heat/air distribution unit product information decal

Interior heat/air distribution unit overview

Styles & Materials Heat Type: Electric heat Forced Air

Heat System Brand: TRANE

Cooling Equipment Type: Electric Cooling

14376 Beach Blvd

Energy Source: Electric

Number of Heat Systems (excluding wood): One

Ductwork: Insulated

Cooling Equipment Energy Source:

Filter Type: Disposable

Central Air Manufacturer: TRANE

Electricity

Page 24 of 37

Precise Home Inspections LLC Number of AC Only Units: One

Doe Age of Heat/AC Air Distribution System: 10 years old IN

6.0 Heating Equipment



6.1 Normal Operating Controls



6.2 Automatic Safety Controls



Distribution Systems (including fans, pumps, ducts and piping, with 6.3 supports, insulation, air filters, registers, radiators, fan coil units and convectors)



6.4 Presence of Installed Heat Source in Each Room



6.5 Cooling and Air Handler Equipment



6.6 Normal Operating Controls



6.7 Presence of Installed Cooling Source in Each Room



6.8 Supply vs Return Air Differential IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

NI NP RR

• IN

NI NP RR

6.3 The HVAC system was last serviced on 8-7-2014.

6.3 Item 1(Picture) Last known service date 6.5 The roof mount AC unit has a sufficient amount rust present. This is normal for a 10 year old unit at the beach. The unit was operating as intended at the time of inspection. This is for your information.

6.5 Item 1(Picture) Roof mount AC unit

14376 Beach Blvd

Page 25 of 37

Precise Home Inspections LLC

Doe

6.8 The ambient air test was performed by using thermometers on the air handler of Air conditioner to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air temperature on your system read 48.2 degrees, and the return air temperature was 64.2 degrees. This indicates the range in temperature drop is normal.

6.8 Item 1(Picture) Supply air temperature is 48.2 degrees

6.8 Item 2(Picture) Return air temperature is 64/2 degrees

The heating and cooling system of this condominium was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

14376 Beach Blvd

Page 26 of 37

Precise Home Inspections LLC

Doe

General Summary

Precise Home Inspections LLC 8810 Lea Brook St Fairhope, AL 36532 251-680-3291 Customer Bob Doe Address 14376 Beach Blvd Orange Beach Al 36561 The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

2(A). Living Room 2.0.A Ceilings Repair or Replace The Sheetrock on the ceiling has stress cracks present in the Living Room. This damage is considered cosmetic. A qualified person should repair as needed.

14376 Beach Blvd

Page 27 of 37

Precise Home Inspections LLC

Doe

2(A). Living Room

2.0.A Item 1(Picture) Ceiling stress cracks present 2.1.A Walls Repair or Replace There are water streaks on a wall (right facing wall). This is from condensation build up on the aluminum air register. This is cosmetic damage. Repair as needed.

2.1.A Item 2(Picture) Air register above water streaks 2.1.A Item 1(Picture) Water streaks present

2(C). Bedrooms 2.0.C Ceilings Repair or Replace (1) The Sheetrock on the ceiling has stress cracks present in the Front Left Bedroom. This damage is considered cosmetic. A qualified person should repair as needed.

14376 Beach Blvd

Page 28 of 37

Precise Home Inspections LLC

Doe

2(C). Bedrooms

2.0.C Item 1(Picture) Ceiling stress cracks present in Front Left bedroom (2) The Sheetrock on the ceiling has stress cracks present in the Left Middle Bedroom. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.C Item 2(Picture) Ceiling stress cracks present in Left Middle Bedroom (3) The Sheetrock on the ceiling has stress cracks present in the Master Bedroom. This damage is considered cosmetic. A qualified person should repair as needed.

14376 Beach Blvd

Page 29 of 37

Precise Home Inspections LLC

Doe

2(C). Bedrooms

2.0.C Item 3(Picture) Ceiling stress cracks present in Master Bedroom 2.1.C Walls Repair or Replace There is a hole in the wall in the Left Middle Bedroom. This is from the entry door knob striking the wall. This is cosmetic damage. Repair as necessary using a qualified person.

2.1.C Item 1(Picture) Damaged wall at Left Middle Bedroom 2.4.C Windows (Representative number) Repair or Replace Could not open the window in the Left Middle Bedroom. Repair or replace as necessary using a qualified person.

14376 Beach Blvd

Page 30 of 37

Precise Home Inspections LLC

Doe

2(C). Bedrooms

2.4.C Item 1(Picture) Could not open the window Left Middle Bedroom

2(D). Bathrooms 2.0.D Ceilings Repair or Replace The Sheetrock on the ceiling has stress cracks present in the Master Bathroom. This damage is considered cosmetic. A qualified person should repair as needed.

2.0.D Item 1(Picture) Ceiling stress crack at Master Bathroom 2.6.D Plumbing Drain and Vent Systems Repair or Replace Slow tub drain in the Hall Bathroom. Possible clog. Repair as needed using a qualified person.

14376 Beach Blvd

Page 31 of 37

Precise Home Inspections LLC

Doe

2(D). Bathrooms

2.6.D Item 1(Picture) Slow tub drain in the Hall Bathroom 2.10.D Shower Surround Repair or Replace (1) Tile grout cracking at Master Bathroom shower surround. Repair as needed using a qualified person.

2.10.D Item 1(Picture) Tile grout cracking at Master Bathroom (2) Shower surround tile is not flush in Hall Bathroom. The tile is secure to the wall. Repair as needed using a qualified person.

14376 Beach Blvd

Page 32 of 37

Precise Home Inspections LLC

Doe

2(D). Bathrooms

2.10.D Item 2(Picture) Shower surround tile not flush in Hall Bathroom

3. Kitchen Components and Appliances 3.0

Ceilings Repair or Replace The Sheetrock on the ceiling has stress cracks present in the Kitchen. This damage is considered cosmetic. A qualified person should repair as needed.

3.0 Item 1(Picture) Ceiling stress crack present 3.1

Walls Repair or Replace The Sheetrock on the wall has a stress crack present in the Kitchen (above the Bar). This damage is considered cosmetic. A qualified person should repair as needed.

14376 Beach Blvd

Page 33 of 37

Precise Home Inspections LLC

Doe

3. Kitchen Components and Appliances

3.1 Item 1(Picture) Wall has stress crack present 3.10 Food Waste Disposer Repair or Replace The food disposer would not operate or is non functional. I recommend repair or replace as needed using a qualified person.

3.10 Item 1(Picture) Waste disposal not working

14376 Beach Blvd

Page 34 of 37

Precise Home Inspections LLC

Doe

Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Brad Robbins

14376 Beach Blvd

Page 35 of 37

Precise Home Inspections LLC

Doe

INVOICE

Precise Home Inspections LLC 8810 Lea Brook St Fairhope, AL 36532 251-680-3291 Inspected By: Brad Robbins

Inspection Date: 1/30/2015 Report ID: 316

Customer Info:

Inspection Property:

Bob Doe

14376 Beach Blvd Orange Beach Al 36561

Customer's Real Estate Professional: Nate Duhe Keller Williams Inspection Fee: Service Condo Inspection

Price

Amount

Sub-Total

225.00

1

225.00

Tax $0.00 Total Price $225.00 Payment Method: Credit Card Payment Status: Paid Note: Invoice with Report

14376 Beach Blvd

Page 36 of 37

Precise Home Inspections LLC

Doe

Precise Home Inspections LLC 8810 Lea Brook St Fairhope, AL 36532 251-680-3291

Report Attachments ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments. Agreement