6
FANS, COOLERS & HEATERS In this Section
Questions? Answers at… Western US: 1-866 CED-ELEV
OR s&AX
%ASTERN53
OR s&AX
or visit us online at
“SEF-E” 2-Speed Propeller Fan . 6.2 “SOE” Dust and Moisture-Proof Blower Wheel Fan . . . . . . . . . . 6.2 “AA” 3-Speed Blower Wheel Fan 6.2 One and Two-Speed Fans . . . . . . 6.3 Two-Speed Exhaust Fans . . . . . . . 6.3 Fan Replacement Parts. . . . . . . . . 6.3 Stand-by Emergency Ventilation for Glass Elevators . . . . . . . . . . 6.3 Emergency Power Supply . . . . . . 6.3 Grills . . . . . . . . . . . . . . . . . . . . . . . . 6.4 Lighted Grills . . . . . . . . . . . . . . . . . 6.4 Heater for Elevator Cab . . . . . . . . 6.4 Tank Heaters . . . . . . . . . . . . . . . . . 6.4 SEIM Tank Cooler . . . . . . . . . . . . . 6.5 Oil-to-Air Heat Exchanger with pump-motor and electric fan . 6.5
www.cedelevator.com
for 24 hour order entry, cross reference data base, product specifications with pictures and much more! Full line catalog available on request 91
6.1
6
Exhaust Fans 2 and 3-Speed Part Number
HP
RPM
FLA
Volts
Phase
Cycle
Cap.
Speeds
06-02016 06-02020
16.4 Watt 14.3 Watt
1450 1250
.77 .41
115 220/230
Single Single
60 50
None None
2 2
Component Specifications
MOUNTING TEMPLATE
11-7/8 DIAMETER HOLE IN CAB
WIRING DIAGRAM
9/32 DIAMETER (4) HOLES EQUALLY SPACED ON 13-3/8 D.B.C.
5.84 REF.
14.00 DIAMETER
FOAM RUBBER PADS
Style Exhaust Pressure configuration by special order only Maximum CFM 350 Features Smallest and least expensive
Model ”SOE“ Dust and Moisture-Proof Blower Wheel Fan
■
FANS, AIR CONDITIONERS & HEATERS
■
Model ”SEF-E“ 2-Speed Propeller Fan
Part Number
HP
RPM
FLA
Volts
Phase
Cycle
Cap.
Speeds
06-01068 06-01070
1/33 1/33
1050 625
.84 .61
115 220/230
Single Single
60 50
None None
3 3
RUBBER MTG. GROMMET
Component Specifications
7.06 TOP OF CAB
Style Exhaust configuration Dust, moisture and explosion-proof models available Maximum CFM 480 Features Most commonly used
15.56
WIRING DIAGRAM
15.18
3.15
Repair Kit #06-01066
FOAM RUBBER PADS
Model ”AA“ 3-Speed Blower Wheel Fan Part Number
HP
RPM
FLA
06-01058 06-01059
1/12 1/12
825 675
1.9 1.4
Volts
Phase
115 Single 220/230 Single
Cycle
Cap.
Speeds
60 50
5 MFD, 370V 5 MFD
3 3
Component Specifications
WIRING DIAGRAM
6.2
Questions? Answers at…
Style Exhaust configuration Dust, moisture and explosion-proof models available Maximum CFM 510 Features Double air inlet for quietest operation Repair Kit #96-13502
Western US: 866 CED-ELEV Eastern US: 866-253-2915
OR s&AX OR s&AX
92
6
Blower and Exhaust Fans
■
One & Two-Speed Fans
Part Number
SSF3C SSFE SSF3R TSF1 TSFE
CFM
Volts
380 325 380 345-300 325-290
115V AC 220VAC, 50-60 HZ 115V AC 115V AC 220VAC, 50-60 HZ
FANS, AIR CONDITIONERS & HEATERS
Engineered for maximum air distribution, our fans are totally enclosed, prelubricated, and easy to install. The 12" x 12" x 41⁄4" 16-gauge steel cage houses a low rpm motor with five blade fan that is both quiet and dependable. Height Speeds
41⁄4" 41⁄4" 41⁄2" 41⁄4" 41⁄4"
1 1 1 2 2
Two-Speed Exhaust Fans
SSF3, TSF1
12” diameter, welded steel housing. Part Number
Maximum CFM
Volts
Height
Speeds
TSFE1420 TSFE1424
375 375
115V AC 115V AC
41⁄2" 31⁄2"
2 2
■
Fan Replacement Parts Part Number
Description
21FN001 21FN002 A01FN001 A01FN002 A01FN003
Single-speed fan motor Two-speed fan motor Two-speed suction blade Single-speed suction blade Single-speed push blade
Stand-by Emergency Ventilation for Glass Elevators
TSFE1420
Ideal for use in glass elevators exposed to direct sunlight. Our fan with emergency power source is designed to exceed the minimum ANSI A17.11989 Section 204.2C requirement of one hour. Bulb type thermostat operates the fan when elevator temperature reaches 80° and shuts off when temperature decreases to 75,° allowing greater time frame for emergency operation. Part Number
SSF4DC
Maximum CFM
Volts
300
12V DC (fan and motor)
PP/SSF4DC
Emergency Power Supply s3EALEDLEADACIDBATTERIESFORUNIFORMDISCHARGEPERFORMANCE s6SOLIDSTATECHARGINGSYSTEMCONSTANTLYMAINTAINS battery charge s)NTHEEVENTOFAPOWERFAILURE THEPOWERSUPPLYWILLRESTORE the charge at the rate of 8 hours for every 4 hours of discharge s#ANBEMOUNTEDHORIZONTALLYORVERTICALLY s HOURPOWERSUPPLY s4ESTSWITCH s)NDICATORLIGHTSCHARGING
Part Number PP/SSF4DC (Replacement supply)
SSF4DC
Questions? Answers at…
Western US: 866 CED-ELEV Eastern US: 866-253-2915
93
OR s&AX OR s&AX
6.3
6 FANS, AIR CONDITIONERS & HEATERS
■
Grills, Heater & Tank Heaters Grills ADGE145SFL ADG-12S
Part Number
Diameter (inches)
Finish
ADG-10 ADG-12 ADG-16 ADG-12S ADG-12B
10 12 16 12
white white white silver BRONZE
Lighted Grills Combination glare-free fluorescent light and air distribution grille. One 40 watt circle line lamp. Durable plexiglass light diffuser. Mounts independent of fan. Part Number
Finish
■
ADGE145SFL Stainless ADGE145BFL "RONZE ADG-FL-CVR (Replacement Fluorescent Cover) ADGE145SI* Stainless ADGE145BI* "RONZE * Incandescent lighting–four 40 watt lamps
Heater for Elevator Cab Ceiling mounted fan forced heater is ideal for parking garages and other area installations Part Number QCH-1151 s.AVAJOWHITESTEELFACEPLATE s,IGHTWEIGHT LBS sWATTS"45HOUR s6!#POWER AMPS s2EMOTETHERMOSTAT s4HERMALCUTOUTTOPREVENTOVERHEATING
Tank Heaters TH120F
THO
TANK HEATER WORKSHEET
The integral thermostat is set for 100° F, has 275W, 6 AND(Z INSTOCK0ERMANENTLYMOUNTED so that turbulence will not move heater in tank. Custom made for your specific applications (Note: “A” Dimension must not exceed 48" maximum. See worksheet for installation specs and size requirements.) Part Number Description
TH120 TH120F THO
(Same as TH120 with standard 40" flex cord) (20 amp red on/off switch with cover)
Tank Heater Worksheet
TH120
Recommended Installation:
6.4
Questions? Answers at…
Western US: 866 CED-ELEV Eastern US: 866-253-2915
OR s&AX OR s&AX
1. If possible, locate heater at bottom of tank, or with minimum of 4" of oil cover. 2. Make all knock-outs and holes above high oil mark in tank. 3. Mount standard switch and cover in utility box if required for summer–winter operation (not furnished, optional). 94
6
Tank Coolers
■
Oil Cooler
FANS, AIR CONDITIONERS & HEATERS
The Oil Cooler can be mounted to the power unit or located in a remote location. When the oil temperature in the reservoir reaches a preset limit, it is circulated throught the radiator. This process reduces the oil temperature by nearly 40°F depending on site conditions. The oil is also filtered as it runs through the system, which results in enhanced performance and extended component life. The filter head has a sight guage to indicate when the filter needs to be changed.
■
Technical data: s(0 6!# PHASE &,!PUMPMOTOROR 208-230 VAC, 1 phase, 3.6 FLA pump motor s(0 6!# PHASE &,!#&-FAN motor or 208-230 VAC, 1 phase, 1.4 FLA 1900 CFM fan motor s(EATREMOVAL "45HR ²&TEMPDELTA s'0- 03)CASTIRONPUMP s7EIGHSAPPROXIMATELYLBS s!DJUSTABLETHERMOSTATCONTROL sDBATFT s%LECTRICALREQUIREMENT 6!# PHASE AMP separate circuit sMICRONlLTERINHYDRAULICOILLINE s&ILTERHEADWITHSIGHTGAUGETOINDICATEWHENTHElLTER needs to be changed s(EAVYGAUGEFRAMECONSTRUCTION s)NCLUDESALLlTTINGSANDHARDWARENEEDEDFOR ADJACENT MOUNTINSTALLATION s)NCLUDESINSTRUCTIONSFORINSTALLATION Part Number 10248 Replacement Filter Part Number 1953
Oil-to-Air Heat Exchanger with pump-motor and electric fan s3TABILIZESTHEOILTEMPERATURE s/PERATESINTHEBYPASSmOWINDEPENDENTOFTHEPOWERUNIT s#ONTROLLEDBYADJUSTABLETHERMOSTATINPOWERUNIT s,OCATEDNEXTTOPOWERUNIT s!DJUSTABLETHERMOSTATANDWALLMOUNTINGBRACKETSINCLUDED Part Number Voltage
Motor
Cooling Capacity
Weight
BUCR2S BUCR3S BUCR4S
1
⁄2 HP 2 HP 2 HP
12,100 BTU/hr 29,000 BTU/hr 47,800 BTU/hr
145 lbs 165 lbs 180 lbs
220/460V 220/460V 220/460V
Dimensions Part Number
D1
D2
D
H
L1
L
BUCR2S BUCR3S BUCR4S
7" 9" 12"
13" 16" 17"
20" 25" 29"
15" 18" 21"
8" 8" 11"
15" 17" 19"
Available Options s#ONTROLLERSTARTER CIRCUITBREAKER FUSESANDTERMINALBLOCKS s&LEXIBLEHOSES s2EPLACEMENTMOTORSBUCR2SM & BUCR4SM 95
Questions? Answers at…
Western US: 866 CED-ELEV Eastern US: 866-253-2915
OR s&AX OR s&AX
6.5
Notes
Questions? Answers at…
Western US: 866 CED-ELEV Eastern US: 866-253-2915
OR s&AX OR s&AX Full line catalog available upon request
96