ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type General Description ZT301 is renewable USA/Japan/China/Ta...
4 downloads 0 Views 230KB Size
ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type General Description ZT301 is renewable USA/Japan/China/Taiwan market RS232 type universal remote control IC.It can control 8 devices at most , includes TV, VCR, Satellite receiver,Cable TV converter, CD, VCD, DVD, HIFI, Tape…

Features z Single chip 8-bit micro-controller

z Serial RS232 protocal baudrate selecting options.

z Operating voltage:2.2V to 5.5V

z TV has TV1 and TV2 two different data groups.

z Operating current:1.0mA to 5.1mA

z VCR1 VCR2 same data device includes VCD and

z Standby current: 1uA to 3uA z Low power dissipation z Ambient operating temperature:0 to +70 ℃ z Storage temperature:-55 to +150 ℃ z Resonator at 3.58M HZ z For TV , VCR, Satellite receiver, Cable TV

VCR and CD z CBL1 CBL2 same data device includes satellite receiver and cable TV converter. z AUX1 AUX2 same data device includes CD, TAPE, DVD, HIFI. z EPROM 24C02 can store 4 pcs of IR code data

converter, VCD, CD, DVD, Tape, HiFi … remote control.

Pin Description Pin

Function

P1.3

Baud rate setting bit3

Vdd

Positive power pin

P1.4

SDA

OSCO

Resonator pin(3.58M)

P1.5

SCL

OSCI

Resonator pin(3.58M)

P1.6

WP

GND

Ground pin

P1.7

IR LED output pin

/RES

System reset pin(Low active)

AGND

Ground pin

TEST

For test mode only

SPK1

DAC1 output(unused)

P0.0

Write data by serial

AVdd

Positive power pin

SPK2

DAC2 output(LED display pin)

P0.1 P0.2 P0.3 P0.4

Read data by serial

P0.5 P0.6 P0.7 P1.0

Baud rate setting bit0

P1.1

Baud rate setting bit1

P1.2

Baud rate setting bit2

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type Absolute Maximum Rating PARAMETER

RATING

UNIT

Supply Voltage to Ground

-0.3 to +5.0

V

Applied Voltage

-0.3 to +5.0

V

Power Dissipation

60

mW

Ambient OP Temperature

0 to +70



Storage Temperature

-55 to +150



TYP.

Min.

Unit

5.5

V

DC Characteristics Parameter

Min.

OP.Voltage

2.4

OP.Current

1.3

5.1

mA

Standby Current

1

3

uA

DAC output

3.67

mA

current Input High Voltage

0.8Vdd

Vdd

Input Low Voltage

0

0.2Vdd

AC Characteristics Parameter

Min.

CPU op. Frequency POR duration

TYP.

Min.

3.58 10

15

Unit MHZ

50

mS

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type

PAD Assignment

Note: (1) Dice Format IC dimension: 2230um(W) x 1930um(H) (2) Substrate connect to groung(GND) (3) Bonding should start from GND pin

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type

Universal Remote Control Apllication circuit 1

3.58MHZ Y1 2

C1 10-100pF

C2 10-100pF Vdd LED

U1

Write pin

Read pin

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Vdd OSCO OSCI GND /RES TEST X32O X32I P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 P2.0 P2.1 ZT201

IR LED SPK2 AVdd SPK1 AGND P1.7 P1.6 P1.5 P1.4 P1.3 P1.2 P1.1 P1.0 P2.7 P2.6 P2.5 P2.4 P2.3 P2.2

36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19

R? 4.7K

R? 4.7K

R? 4.7K

Q1 2N3904

S1 1 2 3 4

U? 1 2 3 4

8 7 6 5

Baud rate setting

A0 A1 A2 GND

Vdd WP SCL SDA

8 7 6 5

24C02 C4 .1uF

C3 100uF

Vdd

R? 100

R? 100

R? 100

WP SCL SDA GND

ZT301 Europe Universal Remote Control Circuit

※ Baudrate setting by switch(all open=9600BPS) ※ EPROM 24C02 can store IR code data by Read/Write pin or directly by WP SCL SDA

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type

Key functions: Setting Device Key: (※Device Key No sending any IR signal) Key Code

Device Name

Code Number

1

TV1

255

2

VCR1

255

3

CBL1

198

4

AUX1

249

5

TV2

113

6

VCR2

255

7

CBL2

198

8

AUX2

249

Key functions: (for TV and CBL) Key Code

TV(CBL)

Function Description

9

POWER

POWER

10

CH+

Channel Up

11

CH-

Channel Down

12

0/10

0 or 10

13

1

14

2

15

3

16

4

17

5

18

6

19

7

20

8

21

9

22

A_V

23

MUTE

24

VOL+

25

VOL-

26

DISPLAY

27

SELECT

28

ENTER

29

+

Increase

30

-

Decrease

31

LCR

Last Channel Recall

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type 32

CATV

33

MENU

34

SLEEP

35

TIME

36

MTS

Multi Language change

37

11/1-

11 or 1-

38

12/2-

12 or 2-

39

AUDIO

Special function

40

PA

Special function

41

PGM

Special function

42

MODE

Special function

43

INPUT

Special function

44

TXT

Special function

45

SAT

Special function

Key Code

VCR(AUX)

Function Description

9

POWER

POWER

10

CH+

Channel Up

11

CH-

Channel Down

12

0/10

13

1

14

2

15

3

16

4

17

5

18

6

19

7

20

8

21

9

22

A_V

23

MUTE

24

VOL+

25

VOL-

26

DISPLAY

27

SELECT/MENU

28

ENTER/SURE

Key functions: (for VCR and AUX)

ENTER or SURE

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type 29

+/UP

Increase or UP

30

-/DN

Decrease or DOWN

31

LCR/LEFT

LCR or LEFT

32

CATV/RIGHT

CATV or RIGHT

33

MENU/MODE

MENU or MODE

34

Fast Forward

35

TIME/CLEAR

TIME or CLEAR

36

MTS/AUDIO

MTS or AUDIO

37

11/1-

11 or 1-

38

12/2-

12 or 2-

39

Backward

40

RECORD

41

PGM/TITLE

PGM or TITLE

42

PLAY

43

PAUSE

44

STOP

45

SAT/SUB

SAT or SUBTITLE

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type

Key Code

SETUP functioms

Function

61 nnn(2 bytes)

SETUP TV1 nnn

62 nnn(2 bytes)

SETUP VCR1 nnn

3 digit number setting VCR1

63 nnn(2 bytes)

SETUP CBL1 nnn

3 digit number setting CBL1

64 nnn(2 bytes)

SETUP AUX1 nnn

3 digit number setting AUX1

65 nnn(2 bytes)

SETUP TV2 nnn

66 nnn(2 bytes)

SETUP VCR2 nnn

3 digit number setting VCR2

67 nnn(2 bytes)

SETUP CBL2 nnn

3 digit number setting CBL2

68 nnn(2 bytes)

SETUP AUX2 nnn

3 digit number setting AUX2

71(1 byte)

AUTOSCAN TV1

AUTOSCAN TV1

72(1 byte)

AUTOSCAN VCR1

AUTOSCAN VCR1

73(1 byte)

AUTOSCAN CBL1

AUTOSCAN CBL1

74(1 byte)

AUTOSCAN AUX1

AUTOSCAN AUX1

75(1 byte)

AUTOSCAN TV2

76(1 byte)

AUTOSCAN VCR2

AUTOSCAN VCR2

77(1 byte)

AUTOSCAN CBL2

AUTOSCAN CBL2

78(1 bye)

AUTOSCAN AUX2

AUTOSCAN AUX2

90(1 byte)

STOP AUTOSCAN

After STOP receive 1 byte code

3 digit number setting TV1

3 digit number setting TV2

AUTOSCAN TV2

number 56 nn XX….(62 bytes)

Send new IR code data

Send new IR code data nn device number 1 TV 2 VCR 3 CBL 4 AUX XX… Total 60 bytes IR code data

Note: 1.

All action must send first byte to wake up CPU and receive 06(ACK) from CPU, then you can begin to send again.

2.

When sending IR code data, nn mean device number 1=TV 2=VCR 3=CBL 4=AUX.

3.

When sending IR code data 60 bytes,each byte CPU will send back 06(ACK) for hand shaking.

4.

To stop AUTOSCAN,you must send 90 to stop,then you willl receive 1 byte of code number from CPU.

This document contains information on a new product under development by ZONTER. ZONTER reserves the right to change this product without notice. Fax:886-7-3890926 @ZONTER Industrial Co.,Ltd. 2005 All rights reserved. http://www.zonter.com.tw Tel:886-7-3829950

ZT301 (Renewable) Universal Remote Control IC (For USA/Japan/China/Taiwan market) RS232 Type

Handshaking Flowchart

Write 1 byte to wakeup MCU No

Read Check ACK(06)?

Yes Write 1 Byte again and next byte

Start

Stop Bit

(1) Start Bit always low Stop Bit always high (2) Above send 8 bits data is Ascii=65(01000001)