550.38-TG2Y (1095)
®
STELLAR 2000 SPLIT-SYSTEM AIR CONDITIONERS “DB” SERIES - 10.00 SEER Models H*DB012 thru H*DB060 Nominal Capacity: 12 thru 60 MBH
DESCRIPTION The HDB Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of YORK’s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal application to provide a complete system. Electric heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces.
LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided,if required. Both quick connect and sweat connect models are available. Both service valves are firmly affixed to the unit. The sweat unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
FEATURES
TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
QUALITY CONDENSER COILS - The coil is constructed of copper tube and hardened aluminum fins for durability and long lasting efficient operation. The fins on the unit are protected with a decorative grille. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight.
LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motorbearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections and a single panel covering the electrical controls make servicing easy. SECURED SERVICE VALVES - Secured re-useable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
550.38-TG2Y
COOLING CAPACITY - With Air Handler and Coils UNIT MODEL
AIR HANDLER MODEL4
ELECT. HT. KW
W
COIL4 MODEL
COOLING7 NET MBH RATED CFM TOTAL SENS.
KW
SEER
SEER/ B.O.D.1
SEER/ S.V.2
EER3
8.7 12.4 12.6 17.0 16.9 19.3 20.7 25.9 27.0 29.0 28.2 33.7 35.2 41.7
1.42 2.05 2.11 2.45 2.47 2.94 2.96 3.77 3.85 4.30 4.33 5.20 5.22 5.98
10.00 10.00 10.30 10.10 10.50 10.30 10.30 10.10 10.40 10.00 10.20 10.00 10.20 10.00
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
-
8.70 8.50 8.50 9.40 9.70 9.70 9.50 9.30 9.50 9.10 9.10 8.80 9.10 9.80
1 & 3 PHASE HDB WITH AIR HANDLERS AND COILS H1DB012
N2AHD06 N2AHD06 N2AHD10
5,8,10,13 5,8,10,13 5,8,10,13,15,20
12 12 16
H1DB024
N2AHD10
5,8,10,13,15,20
16
H1DB030
N2AHD10 N4AHD14
5,8,10,13,15,20 5,8,10,13,15,20,25
16 22
H1DB036
N4AHD14
5,8,10,13,15,20,25
22
N2AHD14 N4AHD16 N2AHD16 N4AHD20 N4AHD20
5,8,10,13,15,20,25 5,8,10,13,15,20,25,30
22 26
5,8,10,13,15,20,25,30
26
5,8,10,13,15,20,25,30
26
H1DB018
H1DB042 H1DB048 H1DB060
G3HC018 G3HC018 G3HC024 G3HC024 G3HC030 G3HC030 G3HC036 G3HC036 G3HC042 G3HC042 G3HC048 G3HC048 G3HC060 G3HC060
450 650 650 850 850 1050 1050 1290 1290 1400 1400 1650 1650 1950
12.4 17.5 18.0 23.0 24.0 28.6 28.0 35.0 36.6 39.2 39.4 46.2 47.4 58.5
1 & 3 PHASE HDB WITH VARIABLE SPEED AIR HANDLERS AND COILS H1DB018
N1VSD10
5,8,10,13,15,20
16
H1DB024
N1VSD10
5,8,10,13,15,20
16
H1DB030
N1VSD10 N1VSD14
5,8,10,13,15,20
16 22
H1DB036
N1VSD14
5,8,10,13,15,20
22
H1DB042
N1VSD14 N2VSD20
5,8,10,13,15,20
22
H1DB048
N2VSD20
5,8,10,13,15,20
22
H1DB060
N2VSD20
5,8,10,13,15,20
22
G3HC024 G3HC024 G3HC030 G3HC030 G3HC036 G3HC036 G3HC042 G3HC042 G3HC048 G3HC048 G3HC060 G3HC060
650 850 850 1050 1050 1290 1290 1400 1400 1650 1650 1950
18.5 24.0 25.0 29.0 28.5 35.0 36.5 39.2 39.4 46.2 47.4 58.5
13.1 18.0 17.3 19.5 19.3 27.9 27.0 28.0 28.2 33.7 35.2 41.7
1.85 2.33 2.35 2.90 2.71 3.57 3.65 4.10 4.10 5.02 5.02 5.77
11.00 10.8 11.0 11.0 11.00 10.90 11.20 11.00 11.20 10.50 10.80 11.20
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
-
10.00 10.30 10.60 10.00 10.50 9.80 10.00 9.60 9.60 9.20 9.40 10.10
650 650 800 800 1035 1035 1250
18.0 18.5 23.2 23.4 28.2 28.4 34.4
13.5 13.1 16.7 16.8 20.8 21.0 25.1
1.99 2.05 2.58 2.55 2.89 2.85 3.85
10.00 10.50 10.00 10.00 10.40 10.80 10.00
10.58 -
-
9.00 9.10 9.00 9.10 9.75 10.00 8.95
800 800 1035 1250 1400
24.0 24.2 28.6 36.0 39.5
17.2 17.5 21.0 26.6 27.6
2.64 2.64 2.85 3.80 4.43
10.2 10.4 10.8 10.5 10.0
10.58 11.08 -
-
9.1 9.2 8.9 9.4 8.9
1 & 3 PHASE HDB WITH COOLING COIL AIR HANDLERS H1DB018 H1DB024 H1DB030 H1DB036
F1RC 018 F1RC 024 F1RC 024 F1RC 030 F1RC 030 F1RC 036 F1RC 036
2.5,5,7.5 5,7.5,10 5,7.5,10 5,7.5,10,15 5,7.5,10,15 5,7.5,10,15 5,7.5,10,15
18
-
1 & 3 PHASE HDB WITH HEAT PUMP COIL AIR HANDLERS H1DB024 H1DB030 H1DB036 H1DB042
F1RP024 F1RP030 F1RP030 F1RP036 F1RP042
5,7.5,10 5,7.5,10,15 5,7.5,10,15 5,7.5,10,15 5,7.5,10,15
18 21.5
-
Rated in accordance with DOE test procedures (Federal Register 12-27-79) and ARI Standards 210 and 270. MBH based on 80°F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1
B.O.D. = Blower Off Delay (Model #2FD06700224). S.V. = Solenoid Valve Kit (Model #2SV06700124). 3 EER (Energy Efficiency Ratio) is the total cooling output in BTU’s is at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. 4 To meet Florida R=4.2 insulation code requirements, substitute N1FA for N2AH, N3FA for N4AH, G1FC for G3HC and F1FC for F1RC models. All ratings remain the same. 5 P2MP, P2MPV and P2UR furnaces have B.O.D. standard. 6 Field transition required between furnace and coil. 7 Standard Cooling Operation is limited to 45 ° F outdoor ambient. 8 TXV = Thermal Expansion Valve Kit. Must be used with Hard Start Kit Accessory. N/R = Not Required. Blower Off Delay standard with air handler. 2
2
Unitary Products Group
550.38-TG2Y
COOLING CAPACITY - With 80% Furnace and Coils UNIT MODEL
FURNACE OUTPUT MBH
MODEL
W
COIL MODEL
RATED CFM
COOLING7 NET MBH KW TOTAL SENS.
SEER
EER3
1 & 3 PHASE HDB WITH UPFLOW FURNACE COILS H1DB012
H1DB018
H1DB024
H1DB030
H1DB036
H1DB042
H1DB048
H1DB060
G3US018 M3UF024 G3US018 M3UF024 G3UA024 M3UF032 G3UA030 M3UF024 G3UA024 G3UA036 M3UF032 G3UA037 M3UF044 G3UA036 M3UF032 G3UA037 M3UF044
450 450 650 650 650 650 800 800 850 850 850 850 850 1050 1050 1050 1050
13.1 13.1 18.2 18.0 18.0 18.0 24.4 23.0 24.0 24.8 23.0 24.8 23.8 29.6 27.6 29.6 28.8
9.5 9.1 13.6 12.9 12.8 12.8 18.2 16.8 18.0 18.8 16.8 18.8 17.3 21.9 18.7 21.9 21.0
1.40 1.43 1.98 1.99 2.00 2.00 2.42 2.39 2.50 2.53 2.49 2.54 2.57 2.98 2.85 2.98 2.99
10.00 10.00 10.40 10.10 10.40 10.40 10.30 10.10 10.10 10.50 10.10 10.50 10.20 10.30 10.30 10.40 10.30
9.40 9.20 9.20 9.00 9.00 9.00 10.10 9.60 9.60 9.80 9.20 9.80 9.30 9.90 9.70 9.90 9.60
16
G3UA036
1200
36.0
26.6
3.83
10.00
9.40
22
G3UA037 M3UF044 G3UA048
1250 1250 1250
36.0 36.0 37.0
26.6 24.9 27.0
3.83 3.72 3.49
10.10 10.50 10.30
9.40 9.70 10.60
22
G3UA048 G3UA060 M3UF044
1400 1400 1350
42.0 42.4 39.2
31.7 32.4 29.4
4.27 4.34 4.24
10.00 10.20 10.00
9.80 9.80 9.20
112
26
G3UA061 M3UF052
1400 1400
42.6 39.2
33.6 29.8
4.43 4.32
10.40 10.00
9.60 9.10
P2MPD165 P2MPD145 P2MPD165 P2MPD205
64 80 96 96
22
G3UA048 G2UT048 G3UA060
1600 1600 1600
48.2 48.0 48.6
36.4 36.2 36.7
5.13 5.10 5.21
10.00 10.00 10.20
9.40 9.40 9.30
P2MPD205
112
26
G3UA061 M3UF052
1600 1600
48.0 45.5
36.4 32.8
5.19 4.91
10.20 10.00
9.20 9.30
P2MPD205 P2MPD205 P2MPD205 P3UCB30
80 96 112 122
22
G3UA060
1950
60.0
42.4
5.97
10.00
10.00
26 32
G3UA061 M3UF064
1950 1975
60.0 56.5
42.1 40.8
5.98 5.91
10.00 10.00
10.00 9.60
P2MPD085
32
12
P2MPD085
32
12
P2MPD08 P2MPD125
48
16
P2MPD085
32
12
5
P2MPD12
48
P2MPD125
64
P2MPD145
80
22
P2MPD125 P2MPD125
48 64
16
P2MPD145
80
22
5
P2MPD12 P2MPD125 P2MPD165 P2MPD145 P2MPD165 P2MPD165 P2MPD145 P2MPD165 P2MPD205
48 64 64 80 96 64 80 96 96
P2MPD205
5
16
See Notes on Page 2.
SOUND RATINGS (ARI STANDARD 270) UNIT MODEL
H1DB UNIT
012 018 024 030 036 042 048 060
7.8 7.6 7.8 8.0 8.2 8.0 8.2* 8.0
SOUND RATING BELS H1DB WITH COMPRESSOR BLANKET ACCESSORY 7.6 7.6 -
CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI
* Compressor Blanket Factory Installed.
Unitary Products Group
3
550.38-TG2Y
COOLING CAPACITY - With 90% Furnace and Coils UNIT MODEL
MODEL
FURNACE OUTPUT MBH
W
COIL MODEL
RATED CFM
COOLING7 NET MBH KW TOTAL SENS.
SEER
EER3
1 & 3 PHASE HDB WITH UPFLOW FURNACE COILS H1DB012
P2URD08
37
14
P2URD08
37
14
P2URD08
55
17
H1DB018
H1DB024
H1DB030
P2URD10
55
P2URD12
74
17
P2URD14
98
21
P2URD10 P2URD10
55 74
17
P2URD14
98
21
74 76 98 112 76 94 112
17
H1DB042
P2URD12 P2URD16 P2URD14 P2URD20 P2URD16 P2URD20 P2URD20 P2URD20
130
24
76 94 112
21
H1DB048
P2URD16 P2URD20 P2URD20 P2URD20
130
24
P2URD20 P2URD20
94 130
21 24
H1DB036
H1DB060
21
21
G3US018 M3UF024 G3US018 M3UF024 G3UA024 M3UF032 G3UA024 G3UA036 M3UF032 G3UA037 M3UF044 G3UA036 M3UF032 G3UA037 M3UF044 G3UA036 G3UA037 M3UF044 G3UA048
450 450 650 650 650 650 850 850 850 850 850 1050 1050 1050 1050 1200 1250 1250 1250
13.1 13.1 18.2 18.0 18.0 18.0 24.0 24.8 23.0 24.8 23.8 29.6 27.6 29.6 28.8 36.0 36.0 36.0 37.0
9.5 9.1 13.6 12.9 12.8 12.8 18.0 18.8 16.8 18.8 17.3 21.9 18.7 21.9 21.0 26.6 26.6 24.9 27.0
1.40 1.43 1.98 1.99 2.00 2.00 2.50 2.53 2.49 2.54 2.57 2.98 2.85 2.98 2.99 3.83 3.83 3.72 3.49
10.00 10.00 10.40 10.10 10.40 10.40 10.10 10.50 10.10 10.50 10.20 10.30 10.30 10.40 10.30 10.00 10.10 10.50 10.30
9.40 9.20 9.20 9.00 9.00 9.00 9.60 9.80 9.20 9.80 9.30 9.90 9.70 9.90 9.60 9.40 9.40 9.70 10.60
G3UA048 G3UA060 M3UF044 G3UA061 M3UF052 G3UA048 G2UT048 G3UA060 G3UA061 M3UF052 G3UA060 G3UA061
1400 1400 1350 1400 1400 1600 1600 1600 1600 1600 1950 1950
42.0 42.4 39.2 42.6 39.2 48.2 48.0 48.6 48.0 45.5 60.0 60.0
31.7 32.4 29.4 33.6 29.8 36.4 36.2 36.7 36.4 32.8 42.4 42.1
4.27 4.34 4.24 4.43 4.32 5.13 5.10 5.21 5.19 4.91 5.97 5.98
10.00 10.20 10.00 10.40 10.00 10.00 10.00 10.20 10.20 10.00 10.00 10.00
9.80 9.80 9.20 9.60 9.10 9.40 9.40 9.30 9.20 9.30 10.00 10.00
See Notes on Page 2.
4
Unitary Products Group
550.38-TG2Y
COOLING CAPACITY - With 78% Furnace and Coils UNIT MODEL
FURNACE MODEL MODEL # MBH
W
COIL MODEL
RATED CFM
COOLING NET MBH KW TOTAL SENS.
SEER
EER
1 Phase HDB / UPFLOW FURNACE & COILS H1DB 018
P1SPD10 P1SPD12
H1DB 024 P1SPD16 P1SPD12 H1DB 030 P1SPD16 P1SPD12 H1DB 036 P1SPD16 P1SPD16 H1DB 042 P1SPD20 P1SPD16 H1DB 048 P1SPD20
H1DB 060
P1SPD20
40
17
40 60 60 80 40 60 60 80 40 60 60 80 60 80 100 120 60 80 80 80 100 120 80 100 120
17 17 20 20 17 17 20 20 17 17 20 20 20 20 23 23 20 20 23 23 23 23 23 23 23
G3UA024 M3UF032 G3UA036 M3UF032 G3UA037 M3UF044 G3UA036 M3UF032 G3UA037 M3UF044 G3UA036 M3UF044 G3UA037 G3UA048
650 650 850 850 850 850 1050 1050 1050 1050 1200 1250 1250 1250
18.0 18.0 24.8 23.0 24.8 23.8 29.6 27.6 29.6 28.8 36.0 36.0 36.0 37.0
12.8 12.8 18.8 16.8 18.8 17.3 21.9 18.7 21.9 21.0 26.6 24.9 26.6 27.0
2.00 2.00 2.53 2.49 2.54 2.57 2.98 2.85 2.98 2.99 3.83 3.72 3.83 3.49
10.4 10.4 10.5 10.1 10.5 10.2 10.30 10.30 10.40 10.30 10.0 10.5 10.1 10.3
9.0 9.0 9.8 9.2 9.8 9.3 9.9 9.7 9.9 9.6 9.4 9.7 9.4 10.6
G3UA048 G3UA060 M3UF044
1400 1400 1350
42.0 42.4 39.2
31.7 32.4 29.4
4.27 4.34 4.24
10.0 10.2 10.0
9.8 9.8 9.2
G3UA048 G3UT048
1600 1600
48.2 48.0
36.4 36.2
5.13 5.10
10.0 10.0
9.4 9.4
G3UT048 G3UA060
1600
48.6
36.7
5.21
10.2
9.3
G3UA060
1950
60.0
42.4
5.97
10.0
10.0
See Notes on Page 2
Unitary Products Group
5
550.38-TG2Y
COOLING CAPACITY UNIT MODEL
FURNACE OUTPUT MBH
MODEL
W
COIL MODEL
COOLING7 RATED CFM
NET MBH TOTAL SENS.
KW
SEER
SEER/ B.O.D.1
EER3
1 & 3 PHASE HDB WITH HORIZONTAL FURNACE COILS H1DB012
P2MPD085
H1DB018
P2MPD085
1.38 1.42 2.12 2.05 2.11
10.10 10.10 10.00
10.00 10.00 10.30
9.50 8.70 8.50 8.50 8.50
-6
M3HD024 M3HD036
850 850
24.0 24.8
17.8 19.2
2.60 2.60
10.20 10.40
-
9.20 9.50
16
G3HC024 G3HC030
850 850
23.0 24.0
17.0 16.2
2.45 2.47
10.00 10.50
10.10 10.50
9.40 9.70
-6
M3HD036
1050
29.0
21.5
2.99
10.20
-
9.70
16
G3HC030
1050
28.6
19.4
2.94
10.00
10.30
9.70
22
G3HC036
1050
28.0
20.1
2.96
10.00
10.30
9.50
-6
M3HD036 M3HD048
1200 1200
34.0 35.0
24.1 25.2
3.79 3.87
10.00 10.00
-
9.00 9.00
-6
G3HC036
1290
35.0
25.9
3.77
10.00
10.10
9.30
22
G3HC036 G3HC042
1290 1300
35.0 36.6
25.9 27.0
3.77 3.79
10.00 10.00
10.10 10.40
9.30 9.60
-6
M3HD048
1400
40.0
28.7
4.31
10.00
-
9.30
22
G3HC042
1400
39.2
28.0
4.30
-
10.00
9.10
26
G3HC048
1400
39.4
28.2
4.33
-
10.20
9.10
-6
M3HD048 M3HD060
1600 1600
47.2 47.6
33.6 33.7
5.19 5.21
10.00 10.00
-
9.10 9.10
-6
G3HC048 G3HC060
1650 1650
46.2 47.2
33.7 35.2
5.20 5.22
-
10.00 10.20
8.90 9.00
-
G3HC048 G3HC060 M3HD060
1650 1650 1950
46.2 47.2 58.0
33.7 35.2 40.9
5.20 5.22 5.91
10.00
10.00 10.20 -
8.90 9.00 9.80
-6
G3HC060
2000
58.5
41.3
5.97
10.00
-
9.80
26
G3HC060
2000
58.5
41.3
5.97
10.00
-
9.80
115 80 96 112
6
P2MPD14
P2HED12 P2HED16 P1HDD12 P1HDD16 P2MPD125
H1DB060
9.5 8.7 13.8 12.4 12.6
26
5
H1DB048
13.1 12.4 18.0 17.5 18.0
112
P1HDD12 P2MPD125
H1DB042
450 450 650 650 650
P2MPD205
P2HED12
H1DB036
M3HD024 G3HC018 M3HD024 G3HC018 G3HC024
P2MPD165 P2MPD145 P2MPD165 P2HED16 P2HED20 P1HDD16 P1HDD20 P2MPD165 P2MPD145 P2MPD165 P2MPD205 P2MPD205 P2HED16 P2HED20 P1HDD16 P1HDD20 P2MPD165 P2MPD205 P2MPD165 P2MPD205
P1HDD12 P2MPD125
H1DB030
32
-6 12 -6 12 16
48 40 60 47 69 48 64 40 60 47 69 48 64 80 40 60 80 47 69 92 48 64 64 80 96 80 100 92 115 64 80 96 96 112 80 100 92 115 64 80 96 96
P2HED12 H1DB024
32
P1HDD20 P2MPD205 P2MPD205 P2MPD205
See Notes on Page 2.
6
Unitary Products Group
550.38-TG2Y
COOLING CAPACITY UNIT MODEL
MODEL
FURNACE OUTPUT MBH
W
COIL MODEL
RATED CFM
COOLING7 NET MBH KW TOTAL SENS.
SEER
EER3
1 & 3 PHASE HDB WITH DOWNFLOW FURNACE COILS H1DB012 H1DB018
H1DB024
H1DB030
H1DB036
P2DPD105
48
P2DPD105 P1CDD10 P2DPD105 P2DPD125 P1CDD10 P1CDD12 P2DPD105 P2DPD125 P1CDD10 P1CDD12
48 57 48 64 57 76 48 64 57 76
P2DPD125
80
P2DPD125
80 80 92 95 80 92 95 104 114 104 114
5
P2DPD16
P1CDD16 H1DB042 H1DB048 H1DB060
P2DPD165 P1CDD16 P2DPD205 P1CDD20 P2DPD205 P1CDD20
G3CN030 M3CF032 G3CN030 M3CF032
450 450 650 650
13.5 13.2 18.0 18.0
9.3 9.4 13.0 12.6
1.40 1.36 1.93 1.92
10.20 10.20 10.10 10.10
9.60 9.70 9.30 9.40
16
G3CN030 M3CF032
850 850
23.0 23.0
17.2 17.2
2.48 2.47
10.00 10.00
9.30 9.40
16
G3CN030 M3CF032
1050 1050
28.0 27.5
20.1 20.0
3.08 2.96
10.00 10.00
9.10 9.30
22
G3CN042 M3CF044
1050 1050
28.0 29.0
20.1 20.8
3.00 2.96
10.00 10.00
9.30 9.70
22
G3CN042 M3CF044
1250 1250
36.0 35.0
26.5 25.1
3.80 3.78
10.00 10.00
9.20 9.20
22
G3CN042 M3CF044
1400 1400
39.0 39.0
27.9 27.8
4.28 4.29
10.00 10.00
9.10 9.10
26
G3CN060 M3CF052
1600 1600
46.2 46.0
33.7 33.2
5.20 4.91
10.00 10.00
8.90 9.40
26
G3CN060
1950
56.5
39.5
5.98
10.00
9.40
16 16
See Notes on Page 2.
COOLING PERFORMANCE MODEL
H1DB012
H1DB018
H1DB024
H1DB030
SUCT. T/P @ COMPR. TEMP. PSIG 35 61.5 40 68.5 45 76.0 50 84.0 35 61.5 40 68.5 45 76.0 50 84.0 35 61.5 40 68.5 45 76.0 50 84.0 35 61.5 40 68.5 45 76.0 50 84.0
AIR TEMP ON CONDENSER 75°F 95°F 115°F MBH KW MBH KW MBH KW 13.2 1.14 11.2 1.24 9.2 1.34 14.7 1.17 12.6 1.28 10.4 1.40 16.4 1.21 14.0 1.33 11.6 1.46 18.0 1.24 15.5 1.37 12.8 1.51 17.3 1.38 14.7 1.51 12.0 1.66 19.3 1.43 16.5 1.58 13.7 1.74 21.4 1.48 18.4 1.65 15.4 1.83 23.5 1.53 20.4 1.73 17.1 1.92 23.4 1.84 19.9 2.01 16.2 2.19 26.1 1.91 22.3 2.11 18.3 2.32 28.9 1.99 24.7 2.22 20.6 2.44 31.7 2.07 27.3 2.32 22.8 2.57 27.4 2.11 23.7 2.34 20.0 2.54 30.0 2.17 26.2 2.43 22.3 2.66 32.8 2.23 28.7 2.52 24.6 2.78 35.7 2.29 31.3 2.61 27.0 2.89
MODEL
H1DB036
H1DB042
H1DB048
H1DB060
SUCT. T/P @ COMPR. TEMP. PSIG 35 61.5 40 68.5 45 76.0 50 84.0 35 61.5 40 68.5 45 76.0 50 84.0 35 61.5 40 68.5 45 76.0 50 84.0 35 61.5 40 68.5 45 76.0 50 84.0
AIR TEMP ON CONDENSER 75°F 95°F 115°F MBH KW MBH KW MBH KW 34.4 2.80 30.0 3.09 25.5 3.35 37.7 2.89 33.0 3.21 28.2 3.51 41.1 2.98 36.2 3.34 31.1 3.67 44.6 3.06 39.4 3.46 34.1 3.82 37.4 3.20 32.1 3.49 26.7 3.71 41.5 3.37 35.8 3.67 30.1 3.92 45.7 3.52 39.5 3.85 33.0 4.14 49.7 3.67 43.3 4.01 36.3 4.33 45.0 3.54 36.9 3.84 30.5 4.03 47.9 3.69 41.1 4.03 34.4 4.27 52.2 3.84 45.1 4.24 38.0 4.53 56.7 3.99 49.3 4.44 41.5 4.80 50.2 4.52 45.1 5.45 39.9 6.39 54.7 4.65 49.1 5.60 44.0 6.45 59.2 4.80 53.5 5.69 47.9 6.58 63.8 4.97 57.8 5.83 51.4 6.79
NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 15° superheat and 15° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling. b. Decrease capacity 1% for each 2° decrease in sub-cooling. 3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°. Maximum recommended condensing temperature is 140°F.
Unitary Products Group
7
550.38-TG2Y
PHYSICAL AND ELECTRICAL DATA - 1 Ø MODELS H1DB... UNIT SUPPLY VOLTAGE NORMAL VOLTAGE RANGE 1 MIN. CIRCUIT AMPACITY MAX. OVERCURRENT DEVICE AMPS 2 COMPRESSOR TYPE RATED LOAD COMPRESSOR AMPS LOCKED ROTOR CRANKCASE HEATER RATED LOAD FAN MOTOR AMPS LOCKED ROTOR MIN. FIELD WIRE SIZE AWG 60°C COPPER CONDUCTORS 208V MAX. WIRE LENGTH FEET BASED ON 3% VOLTAGE DROP 230V FAN DIAMETER INCHES RATED HP FAN MOTOR NOMINAL RPM NOMINAL CFM FACE AREA SQ. FT. COIL ROWS DEEP FIN / INCH LIQUID LINE OD VAPOR LINE OD OPERATING WEIGHT LBS. 1
012
018
024
10.8 15 Recip. 8.0 35.0 NO 0.8 1.7
13.0 20 Recip. 9.7 54.0 NO 0.8 1.7
16.0 25 Recip. 12.1 57.0 NO 0.8 1.7
14
12
12
10
90 100 18 1/8 1075 1950 9.4 1 16 3/8 5/8 120
115 130 18 1/8 1075 1950 9.4 1 16 3/8 5/8 124
95 105 18 1/8 1075 1950 11.3 1 18 3/8 5/8 134
140 155 18 1/8 1075 1950 11.3 1 20 3/8 3/4 135
Utilization range “A” in accordance with ARI standard 110.
030 036 208/230-1-60 187 to 252 17.7 23.2 25 35 Inertia Inertia 13.5 17.3 68.0 94.0 NO YES 0.8 1.6 1.7 3.8
042
048
060
27.2 40 Recip. 20.5 120 YES 1.6 3.8
30.3 45 Inertia 23.0 105 YES 1.6 3.8
37.2 50 Scroll 28.5 170 NO 1.6 3.5
10
10
8
6
105 120 18 1/4 1075 2350 11.3 1 20 3/8 3/4 140
135 150 18 1/4 1075 2200 14.1 1 18 3/8 7/8 155
125 140 18 1/4 1075 2150 17.0 1 20 3/8 7/8 175
115 125 24 1/4 850 3000 20.0 1 18 3/8 7/8 210
H1DB060
8.0 15 Inertia 5.8 40 YES 0.8 1.8
H1DB048 46 460-3-60 432 to 504 9.7 15 Inertia 7.1 64 YES 0.8 1.8
2
Dual element fuses or HACR circuit breaker.
PHYSICAL AND ELECTRICAL DATA - 3 Ø MODELS UNIT SUPPLY VOLTAGE NORMAL VOLTAGE RANGE 1 MIN. CIRCUIT AMPACITY MAX. OVERCURRENT DEVICE AMPS 2 COMPRESSOR TYPE RATED LOAD COMPRESSOR AMPS LOCKED ROTOR CRANKCASE HEATER RATED LOAD FAN MOTOR AMPS LOCKED ROTOR MIN. FIELD WIRE SIZE AWG 60°C COPPER CONDUCTORS 208V 230V MAX. WIRE LENGTH FEET 460V BASED ON 3% VOLTAGE DROP 575V FAN DIAMETER INCHES RATED HP NOMINAL RPM FAN MOTOR NOMINAL CFM FACE AREA SQ. FT. ROWS DEEP COIL FIN / INCH LIQUID LINE OD VAPOR LINE OD OPERATING WEIGHT LBS. 1 2
8
H1DB036
15.2 25 Inertia 10.9 78 YES 1.6 3.8
H1DB048 H1DB060 25 208/230-3-60 187 to 253 20.0 22 30 30 Inertia Scroll 14.7 16.3 130 124 YES YES 1.6 1.6 3.8 3.5
H1DB036
11.4 15 Scroll 8.5 59.6 YES 0.8 2.0
H1DB048 H1DB060 58 575-3-60 517 to 633 8.5 8.0 15 15 Inertia Scroll 6.4 5.9 52 49.4 YES YES 0.5 0.6 1.1 1.5
12
10
10
14
14
14
14
14
105 120 18 1/4 1075 2350 11.3 1 20 3/8 3/4 140
145 160 18 1/4 1075 2150 17.0 1 20 3/8 7/8 169
155 170 24 1/4 850 3000 20 1 18 3/8 7/8 200
310 18 1/4 1075 2350 11.3 1 20 3/8 3/4 140
300 18 1/4 1075 2150 17.0 1 20 3/8 7/8 169
150 24 1/4 850 3000 20 1 18 3/8 7/8 200
425 18 1/4 1075 2150 17.0 1 20 7/8 7/8 169
440 24 1/4 850 3000 20 1.0 18 7/8 7/8 200
Utilization range “A” in accordance with ARI standard 110. Dual element fuses or HACR circuit breaker.
Unitary Products Group
550.38-TG2Y
DIMENSIONS 48" OVERHEAD CLEARANCE
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
C
B
H1DB012 THRU H1DB048
STANDARD GRILLE H1DB060
A
H
AIR IN 4 SIDES
G
VAPOR CONNECTION
5-1/2
LIQUID CONNECTION
MODEL H1DB012 H1DB018 H1DB024 H1DB030 H1DB036 H1DB042 H1DB048 H1DB060
3-1/8
A Height 20-1/8 20-1/8 24-1/8 24-1/8 24-1/8 30-1/8 36-1/8 31-1/8
Dimensions B Width 24 24 24 24 24 24 24 34-1/2
2-3/8
C Depth 24 24 24 24 24 24 24 34-1/2
Wiring K.O.’s* G H Power Control
Refrigerant Connections Line Size Quick Conn Liquid Vapor Liquid Vapor 5/8
7/8 1-1/8
7/8
3/8
3/4
M-6
M - 11
7/8
*Use the 7/8" KO with a 1/2" conduit fitting for #8 AWG wire or smaller. Use the 1-1/8" KO with a 3/4" conduit fitting for #6 AWG wire or smaller.
Unitary Products Group
9
550.38-TG2Y
TYPICAL FIELD WIRING - 1 Ø
ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60
POWER 24 VOLT CONTROL WIRING
FURNACE OR AIR HANDLER TERMINAL BLOCK C
Y
R
G
CONTROL FACTORY
W
CONTROL WIRING
CONTACTOR TERMINALS GROUND SCREW
COIL
Y
R
G
W
*
POWER WIRING
* Terminal W is only required on systems with heat.
ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
USE COPPER CONDUCTORS ONLY.
TYPICAL FIELD WIRING - 3 Ø ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC) AND/OR LOCAL CODES
POWER
POWER WIRING 208/230-3-60 460-3-60 575-3-60
CONTROL FACTORY 24 VOLT CONTROL WIRING
FURNACE OR AIR HANDLER TERMINAL BLOCK C
Y
R
G
W
Y
R
G
W
CONTACTOR TERMINALS GROUND SCREW
COIL
*
ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
10
* Terminal W is only required on systems with heat.
USE COPPER CONDUCTORS ONLY.
Unitary Products Group
550.38-TG2Y
TYPICAL INSTALLATION THERMOSTAT TO BLOWER MOTOR RELAY
WEATHERPROOF DISCONNECT SWITCH
TO POWER SUPPLY
12" REAR AND SIDES
NEC CLASS 1 WIRING
Sit unit on rubber elevator grommets to reduce noise and allow for proper drainage.
NEC CLASS 2 WIRING
TO COIL
48" OVERHEAD CLEARANCE
NOTE: All outdoor wiring must be weatherproof
Seal opening(s) with permagum or equivalent
Unitary Products Group
24" SERVICE ACCESS CLEARANCE
11
MATCHING INDOOR COMPONENTS Typical Application
Add-On Coils - For Furnace Application
➀
➀
UPFLOW FLATTOP M3UF
UPFLOW G3UA
3
1
6
4 2
5
Air Handlers - For Non-Furnace Application
➂ HORIZONTAL M3HD
F1RC / F1FC or F1RP / F1FP FAN COIL UNITS
N2AH, N4AH or N1FA, N3FA BLOWER
G3HC or G1FC COIL
➁ DOWNFLOW FLATTOP M3CF
➁ DOWNFLOW G3CN
➃ UPFLOW ➄ DOWNFLOW ➅ HORIZONTAL
➃ UPFLOW ➅ HORIZONTAL
ACCESSORIES Refer to Price Manual for specific model numbers. Stub Adapters - Available to adapt sweat connect units to quick connect coils or sweat connect coils to quick connect units. Precharged Line Sets - Available in 15, 25, 35 and 50 foot lengths for connection of quick connect models. Outdoor liquid ends have F-6 connectors, vapor ends have F-11 connectors. Indoor liquid ends have M-6 connectors, vapor ends have M-11 connectors. All indoor vapor ends are provided with a 90° bend. A 30 foot line set with straight ends is available for splicing to other lines for longer runs. All vapor lines are insulated with 1/2 sponge rubber. Start Assist Kit - Provides increased starting torque for areas with low voltage conditions. Hard Start Kits - Provides required starting torque for use with Solenoid Valve Kit.
Unitary Products Group P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A. Copyright by York International Corporation 1995. All Rights Reserved.
Off Cycle Timer - Provides a 5 minute off cycle to prevent rapid recycling of the compressor. Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. 2TH07700124 - One stage heat / One stage cool / Nonprogrammable. 2ET07700224 - One stage heat / One stage cool / Programmable, Electronic. 2ET07700324 - One stage heat / One stage cool / Programmable, Electronic. Blower Off Delay - Available to increase efficiency when using Yorkmate control. Installs on indoor section to maintain blower operation for approximately 1 minute on shutdown. Solenoid Valve Kit - Used to improve system performance. Compressor Blanket - Designed to further reduce the normal operating sounds for H1DB units.
SHU 15M 1195 .66
Code: EBY,EGY
550.38-TG2Y Supersedes: 550.38-TG1Y (295)