Refrigerated Compressed Air Dryers

A Company Refrigerated Compressed Air Dryers Deltech Hydrogard® HX Series refrigerated air dryers deliver dry air at an affordable cost. Deltech ...
7 downloads 5 Views 482KB Size
A

Company

Refrigerated Compressed Air Dryers

Deltech Hydrogard® HX Series refrigerated air dryers deliver dry air at an affordable cost.

Deltech Deltech’s Hydrogard® HX Series refrigerated air dryer is simple to operate and easy to maintain.

Dependable Operation Reheater reduces the amount of heat rejection to the ambient air No fouling of the condenser coils from dirt and dust that causes overheating and higher dew points in traditional dryers High evaporator color indicator alerts high temperatures inside the evaporator

HX7-50

Dryers meet CAGI ADF 100 standards

Lowest Operating Cost Maintenance is limited to routine cleaning of the drain

Versatile Installation Compact, lightweight design On/off switch Power on indicating light

HX75-425

6-foot power cord (7-125 scfm) No pipeline sweating - outlet air is reheated

Virtually Maintenance Free Timer-operated drain valve removes condensate (50 scfm and larger) Condenser coils do not foul from dirt and dust; coil spacing up to 4 times greater than traditional dryers

Performance at a Glance Easy to read color indicating suction temperature gauge Alerts high temperature inside chiller System Operation Monitor (optional 500 scfm and larger) • RS232 Port (included with SOM)

Features HX500-3000

No CFC’s Head Pressure Switch Fan Cycling Switch (15 scfm and larger) R134a refrigerant (optional 500 scfm and larger)

Small Footprint Unique heat exchanger • Increased surface area • More efficient than traditional designs • Combined air-to-air and air-to-refrigerant in one (50-150 scfm only) • Compact size

HX500-3000 (Optional)

Sizing Information

Example: Select a dryer for 95 scfm airflow at 90 psig

If inlet conditions are different from rating conditions, dryer capacity will be affected as shown in the Dryer Sizing Chart. Inlet air temperature, ambient air temperature, inlet pressure and air flow must be established before a dryer can be specified for your application.

(6.2 barg) inlet pressure, 90˚F (32˚C) inlet air temperature and 80˚F (27˚C) ambient air temperature conditions.

Step 1: On the Dryer Sizing Chart, locate the inlet air temperature, 90˚F (32˚C).

Step 2: At 90˚F (32˚C) inlet air temperature, read across the chart to 90 psig (6.2 barg) inlet air pressure. The correction factor is 1.18.

Step 3: To adjust the required flow for standard rating conditions, divide the required flow by 1.18.

95 scfm/1.18 = 80 scfm Step 4:

Using the ratings and dimensional data, select a dryer which has a rated capacity of 80 scfm or larger. Select Model HX100.

Step 5: Dryer capacity will also be affected if the ambient air temperature is different from 100˚F (38˚C). For accurate dryer sizing, divide the adjusted dryer flow determined in step 3 by the appropriate correction factor from the table. For 80˚F (27˚C) ambient air temperature, required dryer capacity is:

80 scfm/1.12 = 71 scfm From the ratings and dimensional data, select Model HX75.

The HX Heat Exchanger utilizes a Chevron plate angle that provides high heat transfer and low fouling risk. Models HX500-3000

Dryer Sizing Chart Inlet Air Temperature ˚F (˚C) 70 (21) 80 (27) 90 (32) 100 (38) 110 (43) 120 (49)

20 (1.4)

40 (2.8)

60 (4.1)

80 (5.5)

0.83 0.70 0.59 0.49 0.40 0.33

1.17 0.99 0.84 0.68 0.56 0.46

1.41 1.20 1.01 0.82 0.68 0.56

1.55 1.31 1.11 0.90 0.75 0.61

Correction Factors Ambient Air Temp ˚F (˚C) 80 (27) 90 (32) 100 (38) 110 (43) 120 (49) Inlet Air Pressure psig (barg) 90 100 110 125 (6.2) (6.9) (7.6) (8.6) Correction Factor 1.65 1.72 1.77 1.86 1.40 1.46 1.50 1.58 1.18 1.23 1.27 1.33 0.96 1.00 1.03 1.08 0.80 0.83 0.85 0.90 0.65 0.68 0.70 0.73

Correction Factor 1.12 1.06 1.00 0.94 0.88

150 175 200 (10.3) (12.1) (13.8) 1.96 1.66 1.40 1.14 0.95 0.78

2.02 1.72 1.45 1.18 0.98 0.80

2.08 1.77 1.49 1.21 1.00 0.82

225 (15.5) 2.15 1.83 1.53 1.25 1.03 0.85

Deltech

HX7-HX3000 Engineering Data Model

Flow Capacity1 scfm(Nm3/min)

HX7 HX10 HX15 HX25 HX35 HX50 HX75 HX100 HX125 HX150 HX200 HX250 HX300 HX425 HX500 HX600 HX800 HX1000 HX1250 HX1500 HX2000 HX2500 HX3000 1

2

7(0.2) 10(0.3) 15(0.4) 25(0.7) 35(1.0) 50(1.4) 75(2.1) 100(2.8) 125(3.5) 150(4.2) 200(5.7) 250(7.1) 300(8.5) 425(12.0) 500(14.2) 600(17.0) 800(22.7) 1000(28.3) 1250(35.4) 1500(42.5) 2000(56.6) 2500(70.8) 3000(85.0)

Pressure Drop2

Unit

psig(barg)

Voltage

3.2(.22) 4.2(.29) 3.2(.22) 5.0(.34) 5.0(.34) 4.8(.33) 3.2(.22) 5.0(.34) 4.5(.31) 5.0(.34) 2.7(.19) 2.9(.20) 3.7(.26) 2.9(.20) 4.5(.31) 4.4(.30) 2.3(.16) 3.5(.24) 5.0(.34) 5.0(.34) 5.0(.34) 5.0(.34) 5.0(.34)

115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 460-3-60 460-3-60 460-3-60 460-3-60 460-3-60 460-3-60 460-3-60 460-3-60 460-3-60 460-3-60

RLA

2.5 2.5 2.8 3.7 5.5 5.75 6.0 10.12 10.12 6.26 6.26 7.36 10.40 4.1 5.1 6.0 6.2 8.2 9.3 14.4 16.6 20.2 27.6

kW

Refrigerant Compressor LRA RLA hp

0.25 0.25 0.25 0.35 0.46 0.46 0.58 1.05 1.05 1.30 1.30 1.44 2.23 2.49 3.4 4.1 4.2 5.5 6.3 9.7 11.2 13.6 18.6

20.3 20.3 20.3 14.9 22.0 22.0 25.0 51.0 51.0 28.0 28.0 36.0 45.0 25.0 36.0 33.0 33.0 46.0 55.0 79.0 91.0 104.0 135.0

2.52 2.52 2.52 3.42 5.20 5.20 5.0 9.0 9.0 5.7 5.7 6.8 8.6 3.4 3.7 4.6 4.5 6.4 11.4 11.4 13.4 17.0 23.3

⁄8 ⁄8 1 ⁄8 1 ⁄5 3 ⁄10 3 ⁄10 1 ⁄2 5 ⁄6 5 ⁄6 1 1 1 1⁄4 12⁄3 2 2 3 3 3 5⁄8 4 5 1⁄2 7 1⁄2 10 12 1 1

Minimum Fan Circuit Motor Ampacity watts

3.1 3.1 3.6 4.7 6.9 7.2 7.5 12.7 12.7 7.8 7.8 9.2 13.0 5.1 6.0 7.2 7.3 9.8 11.2 17.3 19.9 24.4 34.7

N/A N/A 4 4 4 6 16 100 100 100 100 100 400 200 460 460 644 644 644 1,196 1,288 1,288 2,392

Fan Refrigerant Motor Refrigerant Charge RLA Type oz. gr.

N/A N/A .32 .32 .32 .55 1.0 1.12 1.12 .56 .56 .56 1.8 .74 1 1 1.4 1.4 1.4 2.6 2.8 2.8 5.2

R134a R134a R134a R134a R134a R134a R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22

5.3 5.3 3.5 8.8 10.2 17.1 19.4 31.7 33.9 44.1 43.4 44.1 77.6 88.2 CF CF CF CF CF CF CF CF CF

150 150 100 250 290 485 550 900 960 1,250 1,230 1,250 2,200 2,503 CF CF CF CF CF CF CF CF CF

Cooling Heat Air Flow Reject. cfm Btuh

N/A 520 N/A 741 141 1,113 141 2,780 141 3,225 176 5,393 345 6,655 587 10,005 587 10,675 587 13,903 587 13,676 587 19,070 2,225 24,464 2,225 27,783 1,500 30,300 1,700 40,300 2,750 46,200 2,750 61,900 3,025 76,300 3,750 98,500 5,500 122,824 6,050 154,939 7,500 188,840

Performance data obtained in accordance with CAGI Standard No. ADF 100, Refrigerated Compressed Air Dryer - Methods for Testing & Rating. Rating conditions are 1000F (37.80C) inlet temperature, 100 psig (6.9 bar) inlet pressure, 100% relative humidity, 1000F (37.80C) ambient temperature and 5 psi (0.34 bar) pressure drop. Pressure drop at rated conditions.

250 scfm model

1000 scfm model

Deltech HX7-35

HEAT EXCHANGER

EVAPORATOR

REHEATER

CHILLER

AUX. CONDENSER

AIR INLET

AIR OUTLET

HX50-425 AIR INLET SUCTION PRESSURE GAUGE

REHEATER

C.I.

AIR OUTLET

COLOR INDICATOR DRAIN OUTLET

CAPILLARY TUBE

CHILLER DRAIN SEPARATOR DRAIN VALVE

FILTER/DRYER

CAPILLARY TUBE

HOT GAS BY-PASS VALVE

DRAIN OUTLET HOT GAS BYPASS VALVE

REF. COMPRESSOR

FAN MOTOR THERMOSTAT

SUCTION STRAINER/ ACCUMULATOR

T.S. SUCTION STRAINER/ ACCUMULATOR

BLADES

COMPRESSOR

CONDENSER

AIR FLOW

FILTER/DRYER

*Models HX7 & HX10 use static condenser.

HX500-3000

CONDENSER F.P.S.

REF COMPRESSOR

FAN PRESSURE SWITCH

COOLING FAN

OUTLET AIR

AIR/AIR EXCHANGER

AIR/REFRIG. EXCHANGER

INLET AIR

SUCTION PRESSURE CONTROL

AIR FLOW ASSEMBLY SUCTION STRAINER/ ACCUMULATOR

Isolation Valve w/ Strainer and Automatic Drain Valve

HEAD PRESSURE CONTROL SEPARATOR

HOT GAS BYPASS VALVE

FAN MOTOR

FAN BLADES EXPANSION VALVE

FILTER / DRYER

CONDENSER

How it Works HX Series dryers use refrigeration cooling to condense entrained moisture out of the air stream. Warm saturated air enters the air-to-air heat exchanger where it is cooled by outgoing cold air. The inlet air is further cooled in the refrigeration chiller. Condensate is removed from the air stream by an automatic drain valve. Models HX7 through HX425 utilize a capillary tube and a hot gas bypass valve (HGBV) that regulates the flow of liquid refrigerant to the chiller, preventing freeze-ups. The HGBV is adjusted at the factory. Operation of the dryer is fully automatic. Models HX500 through HX3000 incorporate a unique design plate type heat exchanger, with a Chevron plate angle that provides high heat transfer and a low fouling risk. The compact, corrosion resistant, stainless steel, plate heat exchanger increases reliability while significantly reducing dryer size and weight. With this heat exchanger design the need for pre-filters is eliminated, providing a great benefit over the competitors’ heat exchanger designs. These models have a thermal expansion valve for precise metering of the refrigerant over a full range of flows. The HGBV works with the thermal expansion valve to prevent freeze-ups from 0-100% of load.

Operating Conditions Max. Inlet Pressure Max. Inlet Air Temp. Min. Inlet Air Temp. Max. Ambient Air Temp. Min. Ambient Air Temp.

7-425 scfm

500-3000 scfm

175 psig (12.1 barg) 120˚F (49˚C) 40˚F (4˚C) 113˚F (45˚C) 40˚F (4˚C)

230 psig (15.8 barg) 120˚F (49˚C) 40˚F (4˚C) 120˚F (49˚C) 40˚F (4˚C)

HX7-HX35

HX300-HX425

Front

Left

Back Back

Left

Front AIR OUTLET

HX500-HX3000

HX50-HX250

COOLING AIR FLOW

A B

AIR INLET

Top

COOLING AIR FLOW

Top L

W

H

OPTIONAL

H

D C

Front

Left Drain

Front

Back

Left

Specifications Model HX7 HX10 HX15 HX25 HX35 HX50 HX75 HX100 HX125 HX150 HX200 HX250 HX300 HX425 HX500 HX600 HX800 HX1000 HX1250 HX1500 HX2000 HX2500 HX3000

H inches/cm

W inches/cm

L inches/cm

15.4(39.1) 15.4(39.1) 22.9(58.1) 22.9(58.1) 22.9(58.1) 20.5(52.1) 27.2(69.1) 27.2(69.1) 35.1(88.9) 35.1(88.9) 35.1(88.9) 35.1(88.9) 42.9(109.0) 42.9(109.0) 55.0(139.7) 55.0(139.7) 55.0(139.7) 55.0(139.7) 55.0(139.7) 55.0(139.7) 60.0(152.4) 60.0(152.4) 60.0(152.4)

12.6(32.0) 12.6(32.0) 11.7(29.8) 11.7(29.8) 11.7(29.8) 11.3(28.7) 12.9(32.8) 12.9(32.8) 16.1(40.8) 16.1(40.8) 16.1(40.8) 16.1(40.8) 19.7(50.0) 19.7(50.0) 27.7(70.3) 27.7(70.3) 27.7(70.3) 27.7(70.3) 27.7(70.3) 27.7(70.3) 46.0(116.8) 46.0(116.8) 46.0(116.8)

12.6(32.0) 12.6(32.0) 21.5(54.6) 21.5(54.6) 21.5(54.6) 29.8(75.7) 29.8(75.7) 29.8(75.7) 38.8(98.5) 38.8(98.5) 38.8(98.5) 38.8(98.5) 46.1(117.0) 46.1(117.0) 36.0(91.4) 36.0(91.4) 36.0(91.4) 36.0(91.4) 36.0(91.4) 36.0(91.4) 66.0(167.6) 66.0(167.6) 66.0(167.6)

A B inches/cm inches/cm 1.7(4.4) 1.7(4.4) 1.7(4.4) 1.7(4.4) 1.7(4.4) 3.8(9.6) 4.0(10.2) 4.0(10.2) 5.6(14.2) 5.6(14.2) 5.0(12.6) 5.0(12.6) 13.4(34.0) 13.4(34.0) 6.9(17.5) 6.9(17.5) 6.9(17.5) 6.9(17.5) 6.9(17.5) 6.9(17.5) 20.5(52.1) 20.5(52.1) 20.5(52.1)

2.0(5.1) 2.0(5.1) 1.8(4.5) 1.8(4.5) 8.3(21.1) 19.1(48.5) 11.9(30.2) 11.9(30.2) 14.9(37.8) 14.9(37.8) 5.8(14.7) 5.8(14.7) 8.9(22.5) 8.9(22.5) 12.2(31.0) 12.2(31.0) 12.2(31.0) 12.2(31.0) 12.2(31.0) 12.2(31.0) 26.0(66.0) 26.0(66.0) 26.0(66.0)

C inches/cm

In-Out D Connections inches/cm Inches NPT

1.4(3.6) 1.4(3.6) 4.2(10.6) 4.2(10.6) 2.0(5.1) 8.7(22.2) 9.8(24.9) 9.8(24.9) 11.6(29.5) 11.6(29.5) 11.3(28.7) 11.3(28.7) NA NA NA NA NA NA NA NA 18.5 (47.0) 18.5 (47.0) 18.5 (47.0)

14.1(35.8) 14.1(35.8) 18.7(47.5) 18.7(47.5) 20.9(53.0) 3.8(9.6) 5.5(14.0) 4.4(11.2) 8.3(21.1) 8.3(21.1) 4.0(10.1) 4.0(10.1) 4.5(11.5) 3.9(10.0) 35.3(89.7) 35.3(89.7) 35.3(89.7) 35.3(89.7) 35.3(89.7) 35.3(89.7) 24.38 (61.9) 24.38 (61.9) 24.38 (61.9)

⁄8 ⁄8 ⁄2 1 ⁄2 3 ⁄4 3 ⁄4 3 ⁄4 1 1 1 1⁄2 2 2 2 1⁄2 2 1⁄2 2 1⁄2 2 1⁄2 3 3 3 3 4FPT 4FPT 4FPT 3 3

1

Approx. Ship Wt. lbs. kg 82 82 93 98 104 148 194 197 268 276 311 322 467 542 550 550 650 675 675 750 1,350 1,350 1,350

37 37 42 44 47 67 88 89 122 125 141 146 212 246 250 250 295 306 306 340 612 612 613

Unit Net Wt. lbs. kg 60 60 71 76 82 124 174 179 244 251 287 298 430 505 507 507 625 650 650 725 1,250 1,250 1,250

27 27 32 34 37 56 79 81 111 114 130 135 195 229 230 230 284 295 295 329 567 567 567

Note: Drain connections are 3/8” NPT up to 425 scfm. 1/4” NPT 500 scfm and up.

ISO9001 7-425 scfm

500-3000 scfm

500-3000 scfm

(Industrial Control Panel Enclosure)

Deltech A Flair Company

4647 S.W. 40th Avenue Ocala, Florida 34474 Tel 352-873-5700 Fax 352-873-5744 E-mail: [email protected] www.deltech-flair.com

U.S. Facilities Ocala, Florida New Castle, Delaware Stanley, North Carolina Houston, Texas

European Facilities Horndean, Hants, England Killarney, Ireland Etten-Leur, The Netherlands Tel 011-31-7650-85800 Fax 011-31-7650-85590

Canadian Facilities Brockville, Ontario Tel 800 893-5247 Fax 800 318-0952

Asian Facilities Jaipur, India Tokyo, Japan Pusan, Korea

Suggest Documents