POWERLOGIC® Power Monitoring and Control Systems Meter Comparison Table
Feature
Value
Phase Current
A, B, C, N
Volts, L-L
A-C, C-B, C-A
Volts, L-N
A-N, B-N, C-N
Real Power (kW)
A, B, C, total
Reactive Power (kVAR)
A, B, C, total
Apparent Power (kVA)
A, B, C, total
Power Factor (true)
A, B, C, total
Enercept Meters
3Ø total
Reactive Energy (kVARh)
3Ø total
Apparent Energy (kVAh)
3Ø total
Energy Accumulation Modes
Signed, Absolute, energy in, energy out
PM600
PM620
PM650
CM2150
CM2250
CM2350
CM2450
CM4000
kf
kq k k kf kf kf k
k
k
kq k k k k k k k k k k k k
k k k k k k k k k k k k k
k k k k k k k k k k k k k
k k k k k k k k k k k k kp
k k k k k k k k k k k k kp
k k k k k k k k k k k k kp
k k k k k k k k k k k k kp
k k k k k k k k k k k k k
M
M
M P
M P
M P
P
P
P
P
Opt
Opt
Opt
k k
k k k
k k k
k k k
k k k
Opt
k k k
k
k
k
k
k
k
k
k k k
k k k
k k k
k k k
k k k
k k k
k
k
k
k
k
k
k
k
k
k
k
k
k k
k k
k k
k k
k k
k k
64
128
128
512
k
k k
k k k k
KYZ Output Communications
Modbus RTU (M) POWERLOGIC (P)
Front Display THD, Voltage & Current
A, B, C
Current Demand
A, B, C, present & peak
Power Demand (kWd, kVARd, kVAd))
3Ø total, present & peak
Date/time stamping
Peak demands, power up/restart, resets
Predicted Power Demand
kW, kVAR, kVA
Advanced Demand Options
Synch to comms, sliding block calculation
Onboard Alarms
Under/over conditions. phase unbalance conditions
Min/Max Readings
Frequency, current, voltage, power, power factor, THD
kc
kj
Data and Event Logs
k
Downloadable Firmware Waveform Capture
Circuit Monitors
Enhanced
Frequency Real Energy (kWh)
Power Meters
Basic
k
M
Samples per cycle
Sag/Swell Detection Programmable Transient Detection Sequence of Events Recording Revenue Accuracy, ANSI
C12.16
C12.16
C12.16
C12.16
C12.16
C12.16
C12.16
C12.20s
Accuracy (of Reading)
Power/Energy Current/Voltage
1%
1%
.5% .25%
.5% .25%
.5% .25%
.4% .2%
.4% .2%
.4% .2%
.4% .2%
.2% .1%
Harmonic Response
Based on sample rate
10
10
31
31
31
31
31
31h
31h
127
k k
k k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
480
480
600
600
600
180v
180v
180v
180v
600v
k
k
UL Listed CUL CSA, CE, NOM Voltage Input
Direct Connect maximum
CTs Included q f p j v s h c
Neutral not available Total power only. Per phase power unavailable. With addition of IOM. Min/max real power only. With addition of PT's unit can monitor up to 1.7MV. Plus revenue metering security switch and tab for wire seal. Waveform capture up to 63rd harmonic.1. Neutral not available. 3 phase total only.
4
POWER MONITORING AND CONTROL
k k
4-2
© 2000 Square D All Rights Reserved
3/00
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Energy and Enercept Meters Class 3020, 3050 PowerLogic Energy Meter The Energy Meter provides the features required for sub-metering along with pricing and convenience that removes the hurdle from getting the information that is needed to make better decisions. The Energy Meter can be used for tenant sub-metering applications where the property manager or building owner may not initially desire a full blown energy management/information system. The Energy Meter can also be used in applications where load dis-aggregation is required. The Basic Energy Meter acts as a standalone meter with display. The Enhanced Energy Meter adds the capability of an optional communication board along with voltage input up to 600 Vac. A multi segment backlit LCD display presents energy consumption in kWh and MWh as applicable. In addition, the display automatically scrolls through the following variables: k kW k KVAR k PF k Volts per phase and 3 phase averagec k Amps per phase and three phase average c c Per phase values are not displayed on single phase meters.
The compatible current transformers (CT) are split-core style for ease of installation. The CT’s come in 125 A, 225 A, 800 A, 1600 A , and 5000 A ranges. The system accuracy including these compatible CT’s is 1% of reading from 2% to 100% of the rated current of the CT’s. The Energy Meter has an Infrared Serial port so that data can be retrieved from the meter using a PDA with infrared capabilities. Catalog Number
Description
EM-B EM-E EM-COB EM-CT01 EM-CT02
Energy Meter Basic Model Energy Meter Enhanced Model Energy Meter Comms Option Board (for Enhanced Model only) Energy Meter CT, 125A Energy Meter CT, 225A
EM-CT08 EM-CT16 EM-CT50
Energy Meter CT, 800A Energy Meter CT, 1600A Energy Meter CT, 5000A
PowerLogic Enercept Meter Enercept Meters consist of three interconnected split core CT’s with the metering and communication electronics built into one of the CT housings. Simply snap on the CT’s, connect the voltage inputs and communication lines, and installation is complete. There are two versions of the Enercept Meter – Basic and Enhanced. They differ only in the amount of metering information provided. The Basic meter reports power and energy only. The Enhanced version delivers 26 energy parameters, including power, energy, demand, volts, amps, power factor, and reactive power. Both versions can be used on either three phase or single phase systems. Enercept Meters employ the Modbus RTU 2-wire communication protocol and can utilize the same communication network and POWERLOGIC System Manager software as other POWERLOGIC devices. Data from the Enercept Meters can be presented within System Manager Software in tabular or graphical format, used for alarming and historical logging and trending, along with producing reports. This makes the Enercept Meter the perfect unit for sub-metering your entire facility. Description
Price
B01-2 B03-2 B04-3 B08-3 B08-4
Enercept Meter, Basic 100 A, 1.25" x 1.51" ID Enercept Meter, Basic 300 A, 1.25" x 1.51" ID Enercept Meter, Basic 400 A, 2.45" x 2.89" ID Enercept Meter, Basic 800 A, 2.45" x 2.89" ID Enercept Meter, Basic 800 A, 2.45" x 5.50" ID
$ 750. 773. 795. 818. 840.
B16-4 B24-4 E01-2 E03-2 E04-3
Enercept Meter, Basic 1600 A, 2.45" x 5.50" ID Enercept Meter, Basic 2400 A, 2.45" x 5.50" ID Enercept Meter, Enhanced 100 A, 1.25" x 1.51" ID Enercept Meter, Enhanced 300 A, 1.25" x 1.51" ID Enercept Meter, Enhanced 400 A, 2.45" x 2.89" ID
863. 885. 1000. 1030. 1060.
E08-3 E08-4 E16-4 E24-4 3050 2W485C
Enercept Meter, Enhanced 800 A, 2.45" x 2.89" ID Enercept Meter, Enhanced 800 A, 2.45" x 5.50" ID Enercept Meter, Enhanced 1600 A, 2.45" x 5.50" ID Enercept Meter, Enhanced 2400 A, 2.45" x 5.50" ID 2-Wire only 232-485 Converter
1090. 1120. 1150. 1180. 75.
3050 EMBK-3 3050 ME-SVR
Enercept Mounting Brackets (Set of 3) Modem Eserver, Data Logger
POWER MONITORING AND CONTROL
Catalog Number
4
72. 676.
3/00
PL1
Discount Schedule
© 2000 Square D All Rights Reserved
4-3
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Monitoring and Control Systems Metering Class 3020 Enercept Communications There are multiple methods for communicating with the Enercept Meter. The Enercept Meter can be tied directly to a computer, can be tied to an E-Server for data logging, or can be connected to a POWERLOGIC network with circuit monitors and power meters.
3050 2W485C
The E-Server is an energy information server that is perfect for:
POWERLOGIC PMX or SMS Software
k Energy aggregation of remote sites k Submetering/metering of large facilities Enercept Meters
k Energy allocation on campuses/bases It is ideal for remote monitoring applications as it provides a flexible, cost effective means to:
E-Server
k Gather energy usage information from multiple sources k Time and date stamp information and store it in battery backed memory (SRAM)
Phone Line
k Accessible from servers (PCs) via modem or local RS232 The E-Server accepts inputs from up to 20 Enercept Meters and consumption pulses from up to four other sources. The E-Server’s ability to accept standard pulsed inputs allows for easy integration of energy usage from water, gas, utility, and sewage meters.
Other Devices
4W-2W Converter
Power Meters The POWERLOGIC Power Meter is capable of replacing a full complement of basic analog meters. This cost effective, true RMS meter can operate as a stand-alone device or as part of a POWERLOGIC Power Monitoring and Control System to help reduce energy and maintenance costs by providing valuable information. k Certified ANSI C12.16 revenue accuracy
Description
k Display mounts in standard 1% meter cutout k Flexible mounting with separate meter and display POWER MONITORING AND CONTROL
Power Meter with Display
k Direct connect up to 600 Vac k Optional 2-Line LCD Display k POWERLOGIC & Modbus RS-485 communications k 0.25% accuracy on current and voltage k On-board event and data logging
Catalog Number
Price
Power Meter Module, Basic Instrumentation
PM600
$1129.
Power Meter Module, Basic Instrumentation, plus Demand, THD, Date/Time Stamping, Neutral Current
PM620
1360.
Power Meter Module, Min/Max, Alarms, Event and Data Storage, plus PM-620 Features
PM650
1678.
Power Meter Display with 1 Foot Cable Serial cable from PM to Display (4ft) Serial cable from PM to Display (12ft) Serial cable from PM to Display (30ft)
PMD32 SC104 SC112 SC130
318. 32. 53. 101.
4
k UL Listed, CSA Approved, CE Marking, NOM Approved
POWERLOGIC is a Registered Trademark of Square D Company or related companies.
4-4
© 2000 Square D All Rights Reserved
PL1
Discount Schedule
3/00
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Metering Class 3020, 3090 The POWERLOGIC Circuit Monitor is a multi-function, digital instrumentation, data acquisition and control device capable of replacing a variety of meters, relays, transducers and other components. Over 50 metered values plus extensive Min/Max data can be viewed on the six-digit LED display. Each Circuit Monitor offers true RMS metering and RS-485 communications standard. Models CM-2150 and above offer 0.2% accuracy true RMS metering and other powerful features such as automatic relay control, waveform capture, on-board event and data logging, and programmable logic for special applications like custom data logging and control function. On-board memory can be expanded to add 512K or 1024K to the CM-2150 and above. Optional add-on input/output modules provide status inputs, a pulse output, relay outputs and analog inputs and outputs. POWERLOGIC Circuit Monitors k Certified ANSI C12.16 revenue accuracy k True RMS Metering through the 31st harmonic Circuit Monitor
k High accuracy: 0.2% on current and voltage k Power quality readings displayed: THD and K-Factor k Harmonic Analysis Data through 63rd harmonic k Automatic Alarm/Relay control k On-board event and data logging k Waveform capture k UL Listed, CSA Approved, CE Marking, NOM Approved k MV-90 compatible Circuit Monitors and Accessories, except I/O Options Class 3020 3020 3020 3020 3020 3020 3020 3020 3020 3020 3020 3020 3020 3020 3020 3090 3090 3090 3090 3090 3090 3090
Catalog No. CM2150 CM2250 CM2350 CM2450 CM2150512K CM2250512K CM2350512K CM2450512K CM21501024K CM22501024K CM23501024K CM24501024K CM2000U CMMEM512K CMMEM1024K VPM277C1 CPM48 RTM317 SMA220 CMA100 CMA110 OCI2000
Description Circuit monitor with full instrumentation (0.2% accuracy), on-board data logging, 100K memory Circuit monitor with full instrumentation, CM2150 features, and waveform capture Circuit monitor with full instrumentation, CM2250 features, and disturbance monitoring Circuit monitor with full instrumentation, CM2350 features, and programmable logic Circuit monitor with full instrumentation (0.2% accuracy), on-board data logging, and 612K memory Circuit monitor with full instrumentation, CM2150 features, waveform capture, and 612K memory Circuit monitor with full instrumentation, CM2250 features, disturbance monitoring, and 612K memory Circuit monitor with full instrumentation, CM2350 features, programmable logic, and 612K memory Circuit monitor with full instrumentation (0.2% accuracy), on-board data logging, and 1124K memory Circuit monitor with full instrumentation, CM2150 features, waveform capture, and 1124K memory Circuit monitor with full instrumentation, CM2250 features, disturbance monitoring, and 1124K memory Circuit monitor with full instrumentation, CM2350 features, programmable logic, and 1124K memory Circuit monitor firmware upgrade kit Circuit monitor 512K memory upgrade kit Circuit monitor 1024K memory upgrade kit Voltage power module for circuit monitor (Series 2000), 480Y/277 V Control power module for circuit monitor (Series 2000), 18-60 Vdc Ride through module for circuit monitor (Series 2000) Surface-mounting adapter with hinged cover for circuit monitor (CM2000) Mounting collar for circuit monitor (CM2000) CM2000 Mounting adapter with accessory compartment Front panel optical communications interface for circuit monitor (CM2000)
Price $2894. 3869. 4547. 5247. 3389. 4364. 5042. 5742. 3669. 4644. 5322. 6022. 245. 495. 775. 231. 648. 376. 178. 86. 144. 773.
Input/Output Options for Circuit Monitor
I/O Module with 1 input and 1 output I/O Module with 8 inputs and 1 output I/O Module with 4 inputs and 4 outputs I/O Module with 2 analog and 8 digital I/O Module with 2 analog and 8 digital I/O Module with 8 analog and 8 digital I/O Module with 8 analog and 8 digital 2' I/O Ribbon Cable Extension With Mounting Hardwaref CM-2000 Ethernet Communications Modulek Remote mounted Ethernet Communications Modulek
Catalog Number IOM11 IOM18 IOM44 IOM441120 IOM441101 IOM444420 IOM444401 RIO110 ECM2000 ECMRM
Price $ 198. 456. 523. 1124. 1124. 1712. 1712. 114. 1325. 1375.
Status inputs can be used as counters, demand synch pulse inputs, and so on. Can be used with 3090 CMA-110. Form C mechanical relay outputs. Supports other POWERLOGIC compatible devices.
4
q f c k
Digital I/O Analog I/O Status Pulse Relay 0-5 Vdc 4-20 mA 0-1 mA Inputsq Outputs Outputsc or 4-20 mA Input Output Output 1 1 – – – – 8 1 – – – – 4 1 3 – – – 4 1 3 1 1 – 4 1 3 1 – 1 4 1 3 4 4 – 4 1 3 4 – 4 – – – – – – – – – – – – – – – – – –
POWER MONITORING AND CONTROL
Description
POWERLOGIC is a Registered Trademark of Square D Company or related companies.
3/00
PL1
Discount Schedule
© 2000 Square D All Rights Reserved
4-5
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Metering Class 3020, 3090 The POWERLOGIC Circuit Monitor CM4000 is a multi-function digital metering and monitoring device capable of replacing a variety of meters, relays, transducers, and other components. Data available for local viewing includes metered values plus extensive min/max, alarm, and analog/digital input data. Circuit Monitor data is available for viewing and recording via standard RS-485, RS-232, or optional Ethernet communications. Two 4-line x 20-character display options are available with user customizable displays. The CM4000 offers 0.1% accuracy, true RMS metering and other powerful features such as 512 points/cycle waveform capture, sag/swell monitoring, waveshape fault monitoring, sequence of events recording, and configurable I/O. The CM4000 can be equipped with either the standard current/ voltage module (CVM) for high accuracy metering or the transient detection version of the current/voltage module (CVM-T) for detecting and recording high speed voltage transients. The CVM-T and the CVM are interchangeable on any CM4000.
POWERLOGIC Circuit Monitor 4000 k True RMS metering through the 127th harmonic
k Field installable digital I/O card
k ANSI C12.20 Revenue Accuracy
k Field installable modular analog/digital I/O extender
k Neutral to ground voltage metering
k Revenue metering security switch and tab for wire seal
k Simultaneous communications port operation k Standard 1 RS-485 and 1 RS-232 Modbus RTU communications port (38.4 KBaud)
k Sag/swell disturbance monitoring
k Optional field installable Ethernet Communications Card with standard web pages
k Extended waveform capture (up to 30 sec)
k Two option card slots for field installable cards
k High speed transient voltage detection and recording
k Wiring diagnostics performed at user request k No PT’s required up to 600 V
k Sequence of events recording using GPS synchronization technology
k Standard 8 Mb of non-volatile memory (field upgradeable)
k UL Listed, CSA Approved, CE Marking, NOM Approved, FCC compliant
k Waveform capture with up to 512 samples/cycle k Oscillatory transient detection and recording
k Standard pulse output (KYZ)
POWERLOGIC Circuit Monitor 4000 Optional Displays k High Visibility remote VF (vacuum fluorescence) display with I/R communications port
k Displays metering data, min/max values, alarms, inputs
k Remote LC (liquid crystal) display with backlighting also available Circuit Monitor 4000
k Optional user configurable display screens
Description Instrumentation, On-board Data Logging Waveform Capture, Disturbance Recording, Configurable I/O, 0.1% Accuracy Same as CM-4000 plus Impulsive Transient Detection
Catalog No.
Priceq
CM4000 CM4000T
Accessories for Circuit Monitor 4000
POWER MONITORING AND CONTROL
Accessory
Catalog No.
Field installable I/O card with 4 status inputs, 3 relay outputs, and 1 pusle output (KYZ) I/O Extender module with 4 analog inputs and 4 analog outputs (4-20 mA) I/O Extender module with 4 status inputs and 4 analog outputs (4-20 mA) I/O Extender module with 8 status inputs I/O Extender module with no pre-installed I/Oc
IOC44 IOX0044 IOX0404 IOX08 IOX
Ethernet Communications Card; 100 Mb Fiber or 10/100 Mb UTP Ethernet port and 1 RS-485 master port Current/Voltage module Current/Voltage module with high speed transient detection 4-line x 20-character Liquid Crystal Display with backlighting 4-line x 20-character Vacuum Fluorescent Display with I/R port and Proximity Sensor
ECC21 CVM CVMT CMD-LC CMD-VF
I/R communications interface for the Vacuum Fluorescent Display 4 foot display cable 12 foot display cable 30 foot display cable
OCI-VF CAB4 CAB12 CAB30
Priceq
4
q Contact your nearest Square D/Schneider Electric sales office. c Contact your nearest Square D/Schneider Electric sales office for user-specified I/O options.
4-6
© 2000 Square D All Rights Reserved
PL1
Discount Schedule
3/00
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Trip Systems and Protective Relays Class 3010, 3030 POWERLOGIC Trip Unit for Low-Voltage Power Circuit Breakers k Includes all protection features of the standard Digitrip series k True RMS sensing k Local readout of metering and diagnostics k Remote monitoring via data communications at baud rates up to 19,200 bps: — RMS currents, per-phase and ground — Demand power and energy — Breaker status (open/closed/tripped) — Cause of trip (type, fault magnitude) — Protective settings and historical information k Integral to breaker - no external current or potential transformers required Digitrip RMS 810D
k POWERLOGIC System compatibility k Retrofit options available The POWERLOGIC trip unit for low-voltage power breakers integrates overcurrent protection, power metering and data communications into a single, compact unit. Featuring true RMS sensing, the trip unit utilizes the breaker’s current sensors and integral potential transformer module, simplifying installation and maintenance. POWERLOGIC application software is available to organize information in a variety of useful formats, and remote control is possible using programmable controllers or computers. Contact your nearest Square D/Schneider Electric sales office for prices. POWERLOGIC Digital Relay k Three-phase (ANSI 50/51) and ground (50/51N or 50/51G) overcurrent protection k User-selectable time-current curves k Local keypad and display of metering and diagnostics
POWERLOGIC Digital Relay
k Remote monitoring via data communications at baud rates up to 19,200 bps: — RMS currents, per-phase and ground — Demand currents, per-phase — Breaker status — Cause of trip (type, fault magnitude) k POWERLOGIC System compatibility k 120 Vac or 48/125 Vdc control power options The POWERLOGIC Digital Relay accepts current inputs from standard 5-Ampere current transformers and is suitable for a wide range of applications on medium-voltage circuits. Remote breaker operation is possible using programmable controllers or computers. Description
Price
DR LX S01 X0A TEN
$2624.
Digital Overcurrent Protective Relay (Three-Phase and Ground) 48/125 Vdc control power
DR LX S01 X0A TBN
2624.
Digital Overcurrent Protective Relay (Three-Phase and Ground) with data communications, 120 Vac control power
DR LX S01 S0A TEN
3279.
Digital Overcurrent Protective Relay (Three-Phase and Ground) with data communications, 48/125 Vdc control power
DR LX S01 S0A TBN
3279.
CSH 30 core balance CT ground fault sensor
CSH 30
117.
CSH 120 core balance CT ground fault sensor
CSH 120
254.
CSH 200 core balance CT ground fault sensor
CSH 200
419.
Rear Cover for Digital Relay
AMT813
207.
4
Catalog No.
Digital Overcurrent Protective Relay (Three-Phase and Ground) 120 Vac control power
POWER MONITORING AND CONTROL
Class 3030 – Protective Relays
POWERLOGIC is a Registered Trademark of Square D Company or related companies. Windows is a Trademark of Microsoft Corporation.
3/00
PL1
Discount Schedule
© 2000 Square D All Rights Reserved
4-7
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Application Software Class 3080 Powerful Software Solutions POWERLOGIC Power Monitoring and Control Systems provide a total, integrated system approach to power management. Circuit monitors and Power Meters provide a tremendous amount of data. POWERLOGIC Application Software turns that data into powerful, useful power monitoring information. Power Information Anytime, Anywhere k Microsoft Windows NT®/Windows® 98 software packages k Easy-to-use–designed with power system engineer in mind k Flexible architecture, from stand-alone PC to client/server k Real-time viewing with customization k Data sharing with ODBC database and client/server DDE over network as well as Active X/DCOM optional custom solutions
Customization
Shares SMS Data through DDE on Client
x
x
x
x
x
x
x
x
x
x
x
x
NT/98
The client application displays information collected by a POWERLOGIC network server. The client application must be used with either SMS-3000, SMS-1500, or PMX-1500. Note: Must be on same PC when used with SMS-1500, PMX-1500 or SMS-121
x
x
x
x
x
SMS1500
NT/98
Stand-alone POWERLOGIC power monitoring application which communicates to devices and displays information collected on the same PC. GFX is optional but must be located x on the same PC. No support for additional clients.
x
x
x
x
x
x
x
x
x
x
x
x
Power Monitoring Stand-alone EXPlorer Stand-alone
PMX1500
NT/98
Stand-alone POWERLOGIC power monitoring application which communicates to devices and displays information x collected on the same PC. GFX is optional but must be located on the same PC. No support for additional clients.
x
x
x
x
x
x
x
x
x
x
System Manager One-to-One Stand-alone
SMS121
NT/98
Stand-alone POWERLOGIC monitoring application which communicates to one device route only, any device type, any x supported communication method. GFX is optional but must be located in the same PC. No support for additional clients.
x
x
x
x
x
x
x
x
x
Add-On
NT/98
Interactive Graphics Client
GFX1000
System Manager Stand-alone
x
x
x
Create Graphical Drawings
Reports
x
SMS1000
x
Manual Control
The client application displays information collected by a POWERLOGIC network server. The client application must be used with SMS-3000.
System Manager Client
Includes POWERLOGIC network server and one SMS client. The POWERLOGIC network server must be located on the PC that is connected to the device network for polling and then x serving the data to client applications over the distributed PC LAN or on the same PC.c
Trending
x
PL Server
Waveform Capture
x
Alarm
x
Logging
x
Bar Charts
x
NT
Meter Panels
x
SMS3000
Real-Time Tables
x
System Manager NT Client/Server
Description
Supports GFX
x
Windows Platform
Set-up Devices and Routing
x
Catalog Number
Supports Network Clients
Automatic Tasks
Reads DDE Data from other Applications
x
Client/Ser.
Class 3080 Product Name
Communicate to Single Devices
x
Monitor Multiple Device Types
x
Application Software Feature Comparison
Communicate to Multiple Devices
x
Real-Time Displays System Manager™ software offers a variety of predefined and customizable real-time data displays.
PL Client
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
New Features Available in System Manager Version 3.1 k Advanced waveform display and harmonic capabilities, including: – Harmonic data spectral plot through the 63rd harmonic for quick analysis of circuit harmonics – Waveform capture overlays to easily compare phase relationships – Zooming control and selection of waveform sections for in depth analysis k Virtual circuit node feature allows you to report and record sums, differences or percentages of real-time monitored values. – Combine data from multiple devices. – Provides accurate cost allocation for departments and facilities. – Help avoid peak demands when there are multiple mains without a summation meter
k Modbus protocol support – Open communications allowing compatibility with Modbus speaking devices k Enhanced compatibility with other software applications k Support non-electrical utility monitoring, such as gas, water, and steam, with proper scaling and units k Tri-lingual language support
4
POWER MONITORING AND CONTROL
c Number of connected clients is dependent upon Windows NT version purchased. NT Workstation allows 10 clients. NT Server allows unlimited clients. DDE is counted as a connected client.
POWERLOGIC is a Registered Trademark of Square D Company or related companies. System Manager is a Trademark of Square D Company or related companies. NT/Windows is a Trademark of Microsoft Corporation.
4-8
© 2000 Square D All Rights Reserved
3/00
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Application Software Class 3080 POWERLOGIC Application Software Description s
Disturbance Monitoring Capture waveforms to analyze power disturbances.
Catalog Number
Price
System Manager™ Client/Server, Windows NT System Manager Client, Windows NT/98 Interactive Graphics Client, Windows NT/98 System Manager Standalone, Windows NT/98 Power Monitoring EXPlorer, Windows NT/98 System Manager One-to-One, Windows NT/98
SMS3000q SMS1000c GFX1000j SMS1500q PMX1500q SMS121q
t t $ 3600. t 4500. 1850.
POWERLOGIC Ethernet Driver for SMS-3000 Software Family
TCPMMS
q c j t q
950.
Requires RS232/RS485 converter or Ethernet Comms. Card. Requires 3080 SMS3000. Requires 3080 SMS3000 or SMS1500 or PMX1500 or SMS121. Contact your nearest Square D/Schneider Electric sales office for pricing. Network card required only for remote client applications and Ethernet communication to device network.
Minimum System Requirements The Square D POWERLOGIC application software requires a computer system with certain minimum requirements (see table below). For your convenience, Square D also offers complete computer systems which include all hardware and software required to meet your operating needs. Please refer to POWERLOGIC Workstations on page 4-12. The table below lists the minimum system requirements. The hard disk requirements for Windows, other software, and logging, memory should also be considered when choosing a computer. Note: Users can select any number of quantities to log. Therefore, the hard disk space required is dependent upon the number of quantities logged. Windows NT/98 SMS-3000a PMX-1500 SMS-1500 SMS-121
SMS-3000 PMX-1500 SMS-1500 SMS-121
Windows NTf Windows 98
Windows NTf Windows 98
VGA (Super VGA recommended)
VGA (Super VGA recommended)
Model
Pentium
486/66 (Pentium recommended)
RAM
64M (128M recommended)
64M (128M recommended)
Hard Disk
500Mp
500Mp
Program Size
50M c
50M c
SY/LINK Card
optional
...
RS-232 Port
required
...
Operating System
Interactive Graphics (GFX-1000) Display system-wide information on drawings such as one-line diagrams, front elevations, or site plans.
Display Mode
Network Card Modem Sound Card
t
t
14.4 or 28.8 (optional)
...
optional
optional
3.5" Drive
u
u
CD Drive
recommended
recommended
a SMS-3000 operates on Windows NT only. f Windows NT, version 4.0 or higher, required in SMS-3000. The other applications run on Windows NT 4.0 or Windows 98. p This figure takes into account only what SMS will use. Any additional applications must be considered separately. The amount of space taken up by SMS on the hard disk depends on whether logging data is stored on the same computer. c SMS uses about 8M; the additional is due to system components. t Required in SMS-3000, to support network clients; optional in other products. u Required unless CD drive is available.
4
For additional functionality, a Billing Module, SQL Database Module and Pager Module are also available. Please contact your nearest Square D/Schneider Electric sales office for pricing.
POWER MONITORING AND CONTROL
Additional Software Options
POWERLOGIC and SY/LINK are Registered Trademarks of Square D Company or related companies. Windows is a Trademark of Microsoft Corporation.
3/00
PL1
Discount Schedule
© 2000 Square D All Rights Reserved
4-9
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems System Components and Packaged Systems Class 3020, 3050, 3070 POWERLOGIC Ethernet Gateway The POWERLOGIC Ethernet Gateway provides a direct connection to Ethernet-TCP/IP networks to make power monitoring and power quality information available over new and existing local and wide area networks. Electrical distribution systems can be better managed using Ethernet technologies and the Internet. Class 3050 – POWERLOGIC Ethernet Gateway Description POWERLOGIC Ethernet Gateway–1 port POWERLOGIC Ethernet Gateway–2 ports
Ethernet Gateway
Type
Price
EGW1
$2385.
EGW2
4028.
POWERLOGIC Ethernet Gateway Mounting Brackets
EGWMBK
133.
POWERLOGIC Ethernet Gateway Null Modem Cable
EGWNMCl
37.
l One required per job for setup.
POWERLOGIC Ethernet Communication Modules The POWERLOGIC Ethernet Communication Module (ECM) connects POWERLOGIC and Modbus/Jbus devices to an industry-standard Ethernet network. The ECM receives, converts, and transmits data over Ethernet using Modbus TCP/IP protocol to your PC where the information can be monitored and analyzed with POWERLOGIC System Manager (SMS) software Class 3020 – POWERLOGIC Ethernet Communication Modules Catalog No.
Price
POWERLOGIC ECM for direct mounting to the back of a Series 2000 circuit monitor and without I/O module
Description
ECM2000
$1825.
POWERLOGIC ECM for remote mounting when circuit monitor is not present or circuit monitor has on-board I/O module
ECMRM
1875.
POWERLOGIC Interface for MICROLOGIC® Circuit Breakers
Ethernet Communication Modules
This interface collects and makes per-phase RMS and ground fault currents, circuit breaker data and trip setting and historical trip data available to the POWERLOGIC system. A single interface supports up to 8 circuit breakers. Class 3050 – POWERLOGIC Product Interfaces Description Product Interface for MICROLOGIC Circuit Breakersq
Catalog No.
Price
PIF3
$2611.
q Requires 1 CIM3F Communications Adapter per Circuit Breaker.
POWERLOGIC Packaged Systems POWERLOGIC is a flexible modular system. An easy way to start building a system is with a Quick Start Kit. These kits contain everything needed to start monitoring power. They include a Circuit Monitor, application software, and a communications cable. Class 3070 — Quick Start Kits Description Quick Start Kit including CM2350, SMS-121 software and OCI (3090 OCI2000)
Catalog No.
Price
QSK2350
$4965.
4
POWER MONITORING AND CONTROL
Product Interface for MICROLOGIC Circuit Breakers
MICROLOGIC and POWERLOGIC are Registered Trademarks of Square D Company or related companies.
4-10
© 2000 Square D All Rights Reserved
PL1
Discount Schedule
3/00
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Engineering Services Class 3000 Power System Studies The Square D Power System Analysis Group provides expertise in a variety of electrical power system studies. These studies can improve the reliability, safety and efficiency of all types of electrical systems, leading to long-term cost savings. For example, a harmonic analysis identifies equipment exposed to destructive harmonics, and provides solutions to increase product life and avoid damage or failure. System studies can provide economic benefits for small and large electrical systems, whether new or existing. Some of the more common system studies include: k Short-Circuit Analysis k Time-Current Coordination k Motor Starting / Voltage Drop k Motor Starting / Torque-Speed Acceleration Analysis k Safe Motor Re-energization k Harmonic Analysis k Transient Analysis k Power Factor Correction Analysis k Other System Specific Analysis For additional information and pricing, contact your nearest Square D/Schneider Electric sales office or write to: Square D Company, 2365 Harrodsburg Road, Suite B410, Lexington, KY 40504. Current in Amperes 1000 500
PU-1
FLA
200 100
3-SE Main 10-NE FDR 2-CS3 Fuse
50
T1-ANSI 20
Time in Seconds
IG-GRD RLY 1-UTIL RLY
10 5
2 1 .5
PMCS Technical Support There are several ways to receive top quality support on POWERLOGIC and POWERLINK products: k Phone 615-287-3400
.2
TX INRUSH X
.1
k Fax 615-287-3403 k Email:
[email protected]
.05
k D-Fax 800-557-4556 (PM&CS Index is Document #104)
.02 .01 .5
1
2
5
10
20
50
100 200
500 1000 2000
5000 10000
Time-Current Coordination Studies are just one of the many power system studies Square D can provide.
POWERLOGIC University POWERLOGIC University offers a number of courses covering POWERLOGIC and POWERLINK products. Training is conducted at the product headquarters, providing an opportunity to meet product developers. POWERLOGIC University Catalog Number
Price q
POWERLOGIC Fundamentals (Self Study Course)
PLUC120CR
q
POWERLINK Fundamentals
PLUC110
q
POWERLOGIC System Installation & Maintenance Certification
PLUC100
q
Comprehensive POWERLOGIC System
PLUC200
q
Comprehensive POWERLOGIC Bundle (2 Courses)
PLUC205
q
SMS-3000 Administrator Certification
PLUC300
q
Energy Management and Advanced Reporting
PLUC230
q
Power Quality with POWERLOGIC Systems
PLUC140
q
Customer Site Training
PLUCSite
q
POWERLOGIC Technical Support CD
PLUCD
q
POWERLOGIC/POWERLINK Priority Technical Support
PSUP100
q
4
PLUC210
POWER MONITORING AND CONTROL
Description POWERLOGIC Update Course
q Contact your nearest Square D/Schneider Electric sales office for schedules, course descriptions, and pricing.
POWERLINK, POWERLOGIC, MICROLOGIC and SY/LINK are Registered Trademarks of Square D Company or related companies.
3/00
PL1
Discount Schedule
© 2000 Square D All Rights Reserved
4-11
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
POWERLOGIC® Power Monitoring and Control Systems Power Management Services Class 3000 Power Monitoring and Control Systems Power System Integration
Power Management Services provides a complete range of design and operational services including specifying, developing, installing, commissioning, supporting, and training users of power monitoring and control systems and remote power switching systems. Engineers maintain expertise in many areas such as communications, personal computers, protective relaying, automatic control systems, and programmable controllers. k System Design and Bill of Material Recommendations k Remote Power Switching System Design k Develop Specifications, Drawings, Documentation k Automatic Control Systems/PLC Ladder Programming, including Load Shed/Peak Shaving Schemes k Custom Hardware/Software Solutions k Third Party Communications Interfaces k Configured Workstations, User Software Interfaces k On-Site Installation Assistance, Component Configuration & Startup k Metering Connection Verification/Testing k On-Site and Headquarters-based Customer Training k Troubleshooting Assistance, Support for Hardware and Software Products k Product Upgrades
Application Engineering can provide the total system solution
k Project Coordination k Power Monitoring Web Server Systems
POWERLOGIC Workstations Square D offers a complete systems approach to power monitoring. POWERLOGIC Application and Engineering provides POWERLOGIC Workstations — tested and approved personal computers completely configured based on the individual system requirements. POWERLOGIC Workstations are designed to handle large amounts of system information, and provide it to those who need it, when they need it. Workstations placed in key locations allow plant engineers, operators, maintenance personnel, and others to make informed decisions using real-time and historical information. Ordering Information POWERLOGIC Workstations should be ordered by description by specifying the following: PC hardware (POWERLOGIC can make recommendations if desired), optional equipment such as modems, printers, etc., and software to be installed and configured.
Application Engineering Catalog Number
Price
Engineering Services System Engineering and Project Coordination
...
q
Custom POWERLOGIC Engineering Services Hardware Personal Computer Workstations, Panels, Enclosures, Interfaces
...
q
Custom POWERLOGIC Engineering Services Software Ladder Logic Programming, Graphics, Reports, Macros
...
q
System Startup - On-site Commissioning
...
q
PowerLink AS Control Module Programming
...
q
Power Quality/Energy Management Engineering Studies
...
q
Portable Circuit Monitor Includes 1 CM2452 Circuit Monitor, VT and CT test leads, communications cables, canvas bag for leads, instruction bulletin
...
q
Portable Circuit Monitor with built-in 19.2k baud modem, or input/ouput module, or both
...
q
Power Management Remote Monitoring Services
...
q
Description
Power Quality/Energy Management
q Contact your nearest Square D/Schneider Electric sales office.
Contact your nearest Square D/Schneider Electric sales office for pricing. PMCS Technical Support
k Phone 615-287-3400 k Fax 615-287-3403 k Email:
[email protected] k D-Fax 800-557-4556 (PM&CS Index is Document #104)
4
POWER MONITORING AND CONTROL
There are several ways to receive top quality support on POWERLOGIC and POWERLINK products:
4-12
© 2000 Square D All Rights Reserved
PL1