Inverter Wall Mounted

Warning PLXRHK1502 Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with you...
9 downloads 2 Views 1MB Size
Warning

PLXRHK1502 Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer.

Caution

Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

DEALER

DAIKIN MALAYSIA SDN. BHD. Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia. www.daikinmalaysia.com DAIKIN INDUSTRIES, LTD. Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan.

Specifications, designs and other content appearing in this brochure are current as of March 2016 but subject to change without notice.

© All rights reserved. Y.K.

Inverter Wall Mounted

Heat Pump FTWS-A Series

Seamless

Elegance

Key Design Concept Cool mode

Heat mode

The gentle lateral curves formed on both sides of this product make it look thinner when installed, thus causing a less oppressive sense. By using many beautifully curved lines that resemble botanical plants, we aimed to create a product with an elegant look and a sense of closeness.

New Wall Mounted A captivating beauty that blends effortlessly with any interior décor and lifestyle. Its curved contour profile with glossy pearl white finishing matched any interior and decor. The contemporary luminescent light that indicates the cool and heat mode can be switched on and off based on personal preference. This unit is truely a blend of style and functonality.

1

2

Compact & Light

Servicing & Installation

Features

Outdoor

Easy access for wiring installation at back panel.

Width: 765mm

Valve positioned at back top panel for easy servicing.

“U-Shape base pan leg front eases installer in fixing unit position.” Installer may fix the bolt before installing the unit.

Height: 420mm Ergonomic handler position for transportation and installation.

Depth: 291mm

Weight: 24kg 3

Drain pan panel for effective water drainage.

Drain hose located at lowest base point of outdoor to ensure smooth water drainage. 4

Comforting

Silence

• Low sound levels at 21dBA to make sure you have peaceful, undisturbed quality sleep.

5

Smarter Way To Save Energy

• Sleep Mode ensures a comfortable environment for a restful sleep. Set temperature is increased or decreased gradually from set temperature to achieve the cozy atmosphere.

POWERFUL

• TiAP (Titanium Apatite Photocatalytic Air-Purifying Filter) that traps microscopic airborne dust particles, absorbs organic contaminants, eliminates bacteria and viruses and breaks down odours.

Reduction of energy consumption while maintaining room comfort.

Maximum cooling/heating power for rapid cooling /heating of the room within the shortest period of time.

ECO+ SENSE

Automatically controls air conditioner operation according to human activity in a room

TiAP

Titanium Apatite Photocatalytic air-purifying filter.

6

SenseFunction Daikin’s FTWS-A series is an intelligent air conditioner that equips with a passive infrared sensor (PIR). Combining with the highly sophisticated algorithm control, it has further extended its offer on comfort and energy saving benefits. The SENSE feature is able to make auto-adjustments on temperature, fan speed and air discharge direction settings when activated. As a result, optimum comfort, spot cooling, energy wastage reduction can be achieved without the need of a user to manually control the settings.

Temperature Control HIGH ACTIVITY

Comfortable Airflow Wide-Angle Louvers The smoothly curved Wide-Angle Louvers provide wide

High activity for a continuous 3 minutes Set Temp: User set temperature -2˚C Fan Speed: User fan speed automatically adjusts to high fan speed

the indoor unit is placed in a room. Vertical Auto-Swing (up and down) to distribute air across a room.

Lifestyle Convenience New Powerful Operation

Air Flow Control

MEDIUM ACTIVITY

Medium activity for a continuous 5 minutes Normal Operation

Function Dictionary

Activating the SENSE option allows temperature to be controlled automatically.

Set Temp: User set temperature Fan Speed: User set fan speed

volume for a 20-minute period. After this, the unit automatically returns to its previous settings. Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.

Cleanliness Titanium Apatite Photocatalytic Air-Purifying Filter

LOW ACTIVITY

trap dust, this photocatalyst absorbs and decomposes proper maintenance. Washable Saranet Filter

Low activity for a continuous 20 minutes Set Temp: User set temperature +2˚C Fan Speed: User set fan speed

ensures cleaner air supply. Wipe-Clean Flat Panel single pass of a cloth across their smooth surface. The cleaning.

7

Comfort Control

Worry Free

Indoor Unit Quiet Operation Indoor unit operating sound levels are decreased by 3dB(A) from the Low setting fan speed using the wireless remote controller. Automatic Operation This function automatically selects cooling or heating operation mode based on the room temperature at start-up. Programme Dry Function This function automatically reduces the level of humidity. Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.

Sense Sense with its Passive Infrared (PIR) sensor automatically controls air conditioner operation according to human activity in a room. It adjusts the fan speed, air flow direction and the set temperature by ±2°C for energy savings and optimum comfort.

Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed).

BLINK

GOLD

Self-Diagnosis Malfunctioning of air conditioner unit by blinking of LED lights for fast and easy maintenance. Anticorrosion Hydrophilic Gold Fin

especially when operating under corrosive and harsh environment.

Timers 24-Hour On/Off Timer This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller. Sleep Mode Pressing the Sleep button activates the Sleep Mode. Cool mode: After 30 minutes, room temperature is raised by 0.5°C. After 60 minutes, room temperature is raised by 0.5°C. After 120 minutes, room temperature is raised by 1°C. Heat mode: After 30 minutes, room temperature is reduced by 1°C. After 60 minutes, room temperature is reduced by 1°C. After 120 minutes, room temperature is reduced by 1°C.

8

Wireless

Specifications

FTWS-AXV1 + RWX-AXV1 (Heat Pump)

Controller

Efficiency Data

Transmission source

25

35

8700 (9300-3300) 2.55 (2.75-0.98) 10900 (11600-4200) 3.20 (3.40-1.25) 3.65

10900 (11900-3700) 3.20 (3.50-1.10) 14300 (14600-3900) 4.20 (4.30-1.15) 4.87

A

4.55

6.94

W

780

1040

W

960

1510

4.94

4.96

1

1

Cooling capacity

MAX-MIN

Heating capacity

MAX-MIN

Running current

Cooling

Btu/hr kW Btu/hr kW A

Running current

Heating

Power consumption

Cooling

Power consumption

Heating

CSPF Energy efficiency grading

“Glow-in-the-dark” ON/OFF button

Temperature setting: Up & down

Powerful: Turbo function Fan speed selection: Low, Med, High, Auto Quiet function Sense function

Vertical automatic air swing Sleep mode function Selectable Mode: Auto, Cooling, Heating, Dry, Fan Eco+ function OFF timer setting

LED function ON timer setting

BRC52B * Please refer to Operation Manual for details of functions.

FTWS-AXV1 T/H/M/L/Q T/H/M/L/Q HxWxD

Outdoor unit

RWX-AXV1

Power supply Sound power level Dimension Net weight Pipe connection

HxWxD Liquid Gas Drain

Pre-charged refrigerant

Real time clock

9

Indoor unit Air flow Sound power level Dimension Net weight Filter type

R410A

Pre-charged piping length Piping Min. length Max. length Max. elevation

cfm dB(A) mm kg

35 25 392/358/282/232/165 378/345/272/215/165 42/41/34/30/22 41/40/34/29/21 297x890x210 297x890x210 9 9 Titanium Apatite Photocatalytic Air Purifying Filter

25

kg

0.65

35 220/1/50 (Power from Indoor) 51/44 420x765x291 25 Ø6.35 Ø9.52 Ø19.05 0.90

m m m m

7.5 2.5 20 10

7.5 2.5 20 10

V/Ph/Hz dB(A) mm kg mm mm mm

220/1/50 (Power from Indoor) 50/44 420x765x291 24 Ø6.35 Ø9.52 Ø19.05

Class 25/35

Class 25/35 comes with gold fin

Note: 1. Indoor unit comes with Titanium Apatite Photocatalytic air purifying filter. 2. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; Outdoor temp. 35°CDB; Piping length 7.5m. 3. Rated heating capacities are based on the following conditions: Indoor temp. 20°CDB; Outdoor temp. 7°CDB; Piping length 7.5m.

10

Suggest Documents