INTRODUCING VNX SERIES

INTRODUCING VNX SERIES February 2011 © Copyright 2011 EMC Corporation. All rights reserved. 1 Next Generation Unified Storage Optimized for today...
Author: Anna West
12 downloads 0 Views 2MB Size
INTRODUCING VNX SERIES

February 2011

© Copyright 2011 EMC Corporation. All rights reserved.

1

Next Generation Unified Storage Optimized for today’s virtualized IT

Unisphere™

VNXe3100

VNXe3300

VNX5100

VNX5300

VNX5500

VNX5700

VNX7500

Affordable. Simple. Efficient. Powerful. © Copyright 2011 EMC Corporation. All rights reserved.

2

Powerful, Flexible Modular Architecture More processing power. Self-optimizing pools. Any network. SAN

NAS

CLOUD

BLOCK

FILE

OBJECT

iSCSI FC FCoE

CIFS NFS pNFS MPFS

SSD

REST SOAP

Unified multi-protocol • • • •

Full support for any network Unified block, file and object support Share volumes and files Fully provisioned LUNs

Multi-controller scale*

HDD

• Add X-blades for the right amount of file sharing power • Add storage processors for more storage pool scale • Scales to 96 CPU cores and 4,000 drives

Self-optimizing storage pools • Active Data is automatically moved to FLASH for fastest performance • Inactive Data is automatically moved out of FLASH to large disks for lowest capacity cost • Fully Automated. Always on. No management intervention needed. Set-it-and-forget-it. • Lowest transaction cost and lowest capacity cost—simultaneously! *2 SP’s requires Gateway with multi back end

© Copyright 2011 EMC Corporation. All rights reserved.

3

Modular Architecture Designed for optimal flexibility

• Scalable capacity and performance

• Native NAS and SAN Implementation • Object delivered via integrated solution

• Simple, powerful, intuitive consolidated management • Future proofed – Flexible IO options – Plug and play

© Copyright 2011 EMC Corporation. All rights reserved.

File Protocol Native File Services (NFS, CIFS, FTP, HA IP networking, IP V6 , AVM, deduplication and compression)

Block Protocol Base Native Block Services (Storage pooling, automation, security, RAID, SAN, etc.)

Disk Expansion

Management

– Dedicated system elements – Flash, SAS and Near-Line for optimal capacity/performance balance – Optimized standalone gateway option

Object Technology (Atmos VE) (Single UI, 3rd party management integration)

• Proven architecture that extends existing Celerra and CLARiiON investment

(Flash, SAS, Near-Line SAS)

4

VNX: Modular Unified and Gateway Implementation models

UNIFIED STORAGE

Gateway

GATEWAY

File Object

File Block Object

Fibre Channel SAN

VNX series

Servers

Symmetrix

VNX series

CLARiiON

• Easy to deploy, simple to manage

• Leverage existing storage investment

• Scale capacity

• Scale performance and capacity

• Multi protocol

• Shared storage

– File: NFS (including pNFS), CIFS, MPFS – Block: iSCSI, Fibre Channel, FCoE – Object: REST, SOAP

© Copyright 2011 EMC Corporation. All rights reserved.

• Add to existing block implementation – File: NFS (including pNFS), CIFS, MPFS – Object: REST, SOAP

5

VNX System Architecture Application servers Exchange servers

Clients

Virtual servers

Oracle servers

Object: Atmos VE

SAN

LAN

VNX Unified Storage FC iS

FCoE

10Gb Enet

FC iS

Failover

VNX X-Blade VNX X-Blade VNX X-Blade VNX X-Blade VNX SP

10Gb FCoE Enet

VNX X-Blade VNX X-Blade VNX X-Blade VNX X-Blade VNX SP

Failover

VNX OE FILE VNX OE BLOCK

Power Supply Power Supply SPS

SPS

LCC

LCC

Near-Line SAS drives

© Copyright 2011 EMC Corporation. All rights reserved.

Flash drives SAS drives

6

VNX Unified Storage Maximum CPU cores of unified data processing power OBJECT

MPFS/pNFS Host AUTOMATIC SERVER OPTIMIZATION

SAN

Build a single cloud with “N” number of systems

NAS

CLOUD Storage Processor

Storage Processor

BLOCK

FILE AND OBJECT

12 cores dedicated to storage pool management and high performance block serving

48 cores dedicated to object, networked file system management and data sharing

AUTOMATIC DATA OPTIMIZATION

Flash

(Highest performance)

SAS

(Good performance)

NL-SAS

(Highest capacity)

VNX supports all protocols—today and in the future © Copyright 2011 EMC Corporation. All rights reserved.

7

VNX Unified Storage Components Architecture and packaging  File implementation: X-Blade enclosure – VNX operating Environment for File – From 2 to 8 blades supported with configurable failover options – Flexible IO connectivity options:

 Block implementation: storage or data processor enclosure* – – – –

VNX operating environment for block Dual active storage processors Automatic failover Flexible IO connectivity options:

 Standby power supplies (battery backup)  Control stations (1 or 2)  Disk array enclosures  Upgradeable to add Fibre Channel ports and/or native 1 or 10 Gigabit Ethernet iSCSI * DPE contains disks, SPE does not contain disks

© Copyright 2011 EMC Corporation. All rights reserved.



15x 3.5” & 2.5” Disk Array Enclosure 25x 2.5” Disk Array Enclosure



25x 2.5”Disk Array Enclosure

Data Mover Enclosure (X-Blade enclosure) Control Station

 

Disk Array Enclosure DPE Disk Processor (Disk Processor Enclosure) Enclosure/Storage 3U Processor Enclosure Standby Power Supply



SAN

Start with FC or iSCSI or NAS Add other protocols seamlessly, as needed

Flexible IO options:

4-port 8Gb FC, 4 port 6Gb SAS, 2 port 10GbE, 4 port Copper 1GbE, 2 Port 10Gb FCoE



8

VNX Storage Processor Dedicated processing for block services Administrator

• Block services – Flexible RAID options (10,3,5,6) provide optimal performance AND protection – RAID Groups and Virtual Pools

Unisphere

• Administration/management

Private Network

– Through storage processor Ethernet ports – Aggregated to single file/block view in Unisphere

• Single point of management/control

Storage Processors

• High availability Active/Active controller failover option

FC/iSCSI SAN VNX

• Connects to Hosts via FC, FCoE, iSCSI for flexibility of connection • Connects to storage via 4 lane 6Gbit SAS for up to 24Gb/SAS bus (6x prior generation)

© Copyright 2011 EMC Corporation. All rights reserved.

9

Flexible Storage Tiers Optimize TCO with tiered service levels SAS back-end connect for performance and reliability

SAS (HDD) options AUTOMATIC DATA OPTIMIZATION

• Up to 24Gb (4x6 Gb) per SAS bus • Point-to-point, robust interconnect

Flash

SAS

Near-line SAS

(10K /15K rpm)

(7.2K rpm)

• Highest performing drives – ~3,000 IOs per second

– 300 GB and 600 GB – 10K and 15K RPM – ~ 140 (10K) to ~ 180 (15K) IOs per second

• 2.5” Drives (500 drives/ rack)

Flash (SSD) options • 3.5” – 100 GB, 200 GB

• 3.5” drives (195 drives/ rack)

Highest performance

Good performance

Highest capacity

– 300 GB and 600 GB – 10K RPM

Near-line SAS (HDD) options

• 3.5” drives (195 drives/ rack) – 2 TB – 7.2K RPM – ˜ 90 IOs per second

© Copyright 2011 EMC Corporation. All rights reserved.

10

VG2 and VG8 Gateway Components Architecture and packaging  File implementation: X-Blade enclosure

 SAN

– VNX operating environment for file – Configurable blade options 2 to 8  Primary/standby with automatic failover  Primary/primary with quick reboots for entry platforms

Symmetrix

VNX series

CLARiiON

 N+M advanced failover for four+ blade systems

– Flexible IO connectivity options:  Four x 10/100/1000 copper Ethernet ports  Two x Gigabit Ethernet optical plus two x 10/100/1000 copper ports  Two x 10 Gigabit Ethernet optical ports

 Control stations (one or two) – Configuration and management – Reliability, availability, serviceability

 Symmetrix, VNX, or CLARiiON storage

© Copyright 2011 EMC Corporation. All rights reserved.

DME (Data Mover Enclosure) 2U



CS (Control Station) 1 U



11

VNX X-Blades Run the world’s most mature NAS operating system • Up to eight independent file servers contained in a single system – Scale by adding enclosures: 2 X-Blades per X-Blade enclosure

Network X-Blade X-Blade X-Blade

X-Blade Enclosure

X-Blade

Control Station Control Station

• Managed as one, high-performance, highavailability server • Connects data to the network

• VNX operating environment for file – No performance impact after failover – Concurrent Network File System (NFS), Common Internet File System (CIFS), File Transfer Protocol file access, MPFS/pNFS

• Hot-pluggable VNX series VNX, Symmetrix or CLARiiON

© Copyright 2011 EMC Corporation. All rights reserved.

• Flexible N-to-M failover options • Continues to operate even if control station fails • No internal disks in the Gateway

12

VNX Control Station Secure management and control for VNX for file • Installation

• Administration/management – Through X-Blade and Storage Processor Ethernet ports

Administrator

• Configuration changes

Unisphere

• Monitoring and diagnostics – Heartbeat pulse of X-Blade

Private Network

• Monitors and manages X-Blade failover Control Station Control Station

Control Station VNX series

• Enterprise Linux-based (RHEL 5) • Initiates communications with X-Blades for greater security • Single point of management/control • Failover redundancy option

© Copyright 2011 EMC Corporation. All rights reserved.

13

VNX Object Support A SINGLE CLOUD BUILT WITH VNX SYSTEMS

SOFTWARE ON VMWARE

UNISPHERE GUI INTEGRATION

Certified with EMC Unified Storage (NFS, FC, iSCSI); VMware-supported servers and third-party storage

REST, SOAP, HTTP or Web access Object Technology (Atmos/VE)

Atmos Virtual Edition

No limits on namespace or location Multi-tenancy securely isolates data Automated location, protection, and efficiency services

NEW Tokyo

New York

London

Flexibility VMware vSphere

NFS/FC/iSCSI Storage  Starts at 10 TB  Up to 960 TB per site

© Copyright 2011 EMC Corporation. All rights reserved.

14

Atmos VE on VNX

Custom Web Application

Atmos ISV Application

File System Access

REST and SOAP access methods Global scale namespace spans locations

• Storage

Multi-tenancy securely segregates data Policies automate data services

– vSphere-supported FC/iSCSI/NFS – Storage can be from more than one array

• vSphere – vSphere HCL supported servers – Minimum 2 servers required

Atmos Virtual Edition Atmos Node

Atmos Node

Atmos Node

ESX Server

Atmos Node

ESX Server

• Atmos access/integration layer – Customer web application using Atmos REST/SOAP API – Pre-integrated ISV application (e.g. Documentum)

ESX Server

Atmos Node

Atmos Node

ESX Server

Scales large and fast Self-optimizes for performance and capacity efficiency

VNX5100

© Copyright 2011 EMC Corporation. All rights reserved.

Atmos Node

IP/FC

• Virtual machines – Atmos SW is installed on the VMs – Access methods are configured on VMs

Atmos Node

VNX5300

VNX5500

VNX5700

VNX7500

15

VNX Modular Architecture—LUNs and File Systems CIFS or NFS X-Blade File Services X-Blade File Storage Pool

• Thin or Thick LUNs are simply built from the Virtual Pool • LUNs can be shared to block connected Hosts (FC, iSCSI, FCoE)

• File services added • LUNs are configured for file and consumed by X-Blade Block Storage Processor Virtual Blended Storage Pool FLASH

15K SAS

Thick LUN

Near-Line Thin SAS

• File systems optimally built via Automated Volume Management and shared via NFS or CIFS

LUN

SAN

© Copyright 2011 EMC Corporation. All rights reserved.

16

VNX Series Software Components Software solutions made simple Base software (no additional charge)

File deduplication & compression, block compression, virtual provisioning, SAN Copy, and protocols

Attractively Priced Packs and Suites VNX Suites

FAST VP, FAST Cache, Unisphere Analyzer, Unisphere Quality of Service Manager

FAST Suite

Event Enabler (anti-virus, quota management, auditing), Filelevel retention, host encryption

Security and Compliance Suite

SnapView, SnapSure, RecoverPoint/SE CDP

Local Protection Suite

Replicator, MirrorView A/S, RecoverPoint/SE CRR

Remote Protection Suite

Replication Manager, Data Protection Advisor for Replication

Application Protection Suite

VNX Packs

VNX Total Efficiency Pack

Unisphere

Total Protection Pack

Management software

VNX5100 does not support FAST VP, VEE, FLR, Replicator, or SnapSure. It also does not support the Total Efficiency Pack, but a Total Value Pack instead.

© Copyright 2011 EMC Corporation. All rights reserved.

17

The FAST Suite Highest performance and capacity efficiency—automatically! Real-time caching with FAST Cache

Flash SSD

HighPerformance HDD

Scheduled optimization with FAST VP

• FAST Cache continuously ensures that the hottest data is served from high performance FLASH SSDs

Highcapacity HDD

• FAST VP (Virtual Pools)* optimizes storage pools automatically, ensuring that active data is being served from SSDs, while cold data is moved to lower cost disk tiers • Together they deliver a fully automated FLASH 1st storage strategy for optimal performance at the lowest cost attainable • Monitor and Tune the whole system with the complementary Unisphere QoS Manager and Unisphere Analyzer

* Not available for VNX5100.

© Copyright 2011 EMC Corporation. All rights reserved.

18

FAST Cache Overview Run SQL and Oracle up to 3X faster Exchange

SAP

VMware

Oracle Database

SharePoint

File

• Extends mid-tier cache using Flash drives

Fastest

30

Performance

8

• Support for file and block

– Adds up to 2 TB of cache

DRAM

• Less than a third of the cost of DRAM

FAST Cache

Capacity

1

© Copyright 2011 EMC Corporation. All rights reserved.

• Hot data automatically ends up in FAST Cache • RAID 1 for Read/Write protection

Disk Drives

• Transparent to SP failure, no need to warm up the cache • Applicable to most workloads

19

FAST Cache Approach Exchange

SAP

VMware

Oracle Database

SharePoint

File

 If not, FAST Cache driver checks map to determine where page is located

DRAM Policy Engine

MAP

 Page request satisfied from disk drive if not in FAST Cache

 Policy Engine promotes a page to FAST Cache if it is being used frequently

Driver

FAST Cache

 Page requests satisfied from DRAM if available

Disk Drives

 Subsequent requests for this page satisfied from FAST Cache  Dirty pages are copied back to disk drives as background activity

© Copyright 2011 EMC Corporation. All rights reserved.

20

FAST VP for Block and File Access Optimize VNX for minimum TCO BEFORE

AFTER

Automates

Pool Tier 0

LUN 1

movement of hot or cold blocks

Optimizes Tier 1

LUN 2

use of high performance and high capacity drives

Improves Tier 2 Most activity

Neutral activity

© Copyright 2011 EMC Corporation. All rights reserved.

cost and performance

Least activity

21

FAST VP Policies Policy ensures storage service levels are met 1

Highest Tier Preferred Maximize performance e.g. high-performance OLTP system

2

Auto-Tier Optimize TCO and performance e.g. databases with varied levels of activity among tables, or file systems with varied levels of activity across files

3

Lowest Tier Preferred Reduce TCO e.g., archived or infrequently accessed data

LUN 1

LUN

SSD

© Copyright 2011 EMC Corporation. All rights reserved.

LUN

2

3

HDD

22

FAST VP Operational Process • Statistics collection—cumulative I/O history (reads and writes) – Weights recent I/O history above longer-term I/O history – Maintains relative ranking of all data in pool, based on tier preference and I/O history: • Highest tier preference and high activity level get highest priority • Highest tier preference with less activity level get next highest priority • No tier preference (Auto-Tier) with high activity level gets next highest priority

• When a pool is created, it is detected in the next poll cycle for inclusion in statistics collection – LUNs created in pool are likewise detected in the next poll cycle for inclusion in statistics collection – Poll occurs every hour – Relocation estimate—“amount to move up/down”—updated every hour

• Tier utilization – Algorithm attempts to gain greatest utility from highest tiers • Data is demoted as space is needed in top tiers

• Relocation granularity – Sub-LUN “slices” are 1 GB granularity

© Copyright 2011 EMC Corporation. All rights reserved.

23

VNX Security and Compliance Suite Keep data safe from changes, deletions, and malicious activity EMC VNX Host Encryption

EMC VNX File-level Retention (FLR)

EMC VNX Event Enabler (VEE)

• Maintains data confidentiality for data at rest, provides compliance

• Provides the ability to lock down (WORM) file systems to avoid malicious or accidental changes

• Delivers alerts upon file system actions

• Encrypts data where it is created—providing protection anywhere outside the server

• Supports file-level retention periods

© Copyright 2011 EMC Corporation. All rights reserved.

• VNX File-level Retention Compliance Option (FLR-C) meets SEC Rule 17a-4(f) compliance requirements

• Allows integration with third-party anti-virus checking, quota management, and auditing applications

24

Options for Data Protection Traditional Backup Daily Backup: Recovery point every 24 hours

SnapViewithSnapSure Snapshots/Clones: Recovery point every 3 hours

MirrorViewithReplicator Disk Mirroring: Recovery point latest image replicated

RecoverPoint/SE CDP and CRR Continuous Data Protection: DVR like recovery Unlimited recovery points, application bookmarks (T) TIME Checkpoint

Pre-Patch

© Copyright 2011 EMC Corporation. All rights reserved.

Patch

Post-Patch

Cache Flush

Hot Backup

Quarterly Checkpoint Close

25

VNX Local Protection Suite Practice safe data protection and repurposing SnapView and SnapSure

RecoverPoint/SE CDP

• Production data copies for instant recovery on file and block storage

• DVR-like roll-back of production applications to any point-in-time

• Streamline data protection and repurposing use cases – Development/QA testing – Reporting/decision support tools – Backup acceleration

© Copyright 2011 EMC Corporation. All rights reserved.

• Granular recovery to the I/O level for VNX for Block storage

• Self-service recovery with tighter RPO and flexibility • Streamline data repurposing

26

VNX Remote Protection Suite Ensure your data is physically protected all the time RecoverPoint/SE Continuous Remote Replication (CRR) • One solution to protect any host, any application

MirrorView • Synchronous or asynchronous one to many block replication solution

– Unified block and file replication

• Efficiently protect all your data – WAN deduplication for bandwidth reduction up to 90%

• Customize RPOs from zero to hours for improved quality of service • Immediate DVR-like recovery

© Copyright 2011 EMC Corporation. All rights reserved.

Replicator* • Scheduled asynchronous file system level replication including one to many and cascading replication * Not available for VNX5100

27