HYDRONIC

INDEX

HYDRONIC CONTROLS

133 – 144

Model(s)

Description

1311 / 1361 ..................................................... 1300 ................................................................. 1300 ................................................................. 445 / 1687 / 752 ............................................... 750 Series . ...................................................... 1100 Series........................................................ 1100 Series........................................................ 1100 Series........................................................ 1100 Series........................................................ 1100 Series........................................................ 800 Series.......................................................... 800 Series..........................................................

2-Wire or 3-Wire Hydronic Zone Controls.......................................................... 134 Series Direct-Connect Type................................................................................ 135 Series Adaptor Type........................................................................................... 136 Remote Temperature Controls/Automatic Change-Over Controls..................... 137 Electric Water Heater Thermostats..................................................................... 138 Remote Bulb Types .......................................................................................... 139 Well Immersion Single Control ......................................................................... 140 Dual Action – Single Element Controls . ........................................................... 141 Surface (Strap-On) Types ................................................................................ 141 Fast Response Direct Immersion Controls . ..................................................... 142 Combination High Limit/Switching Relay Controls ........................................... 143 Combination High Limit/Low Limit-Circulator Switching Relay Controls .......... 144

Page(s)

RELAY TRANSFORMERS

145 – 146

Model(s)

Description

Page(s)

800 Series . ..................................................... Relay/Transformer Combinations....................................................................... 145 1000 Series . .................................................... Adjustable Indoor-Outdoor Control..................................................................... 146

IMMERSION WELLS

147

Model(s)

Description

Page(s)

Immersion Wells ............................................ Immersion Wells and Packing Nuts.................................................................... 147

PARTS AND ACCESSORIES

148

HYDRONIC CONTROLS INDEXED BY RANGE Range Min.

Differential Max.

Differential Min. Model Element

90°F

-30°F

40°F

4.5°F

1687-9

Remote Bulb

8 feet

SPDT 137

90°F

20°F

20°F

4°F

445-6

Remote Bulb

5 feet

SPDT 137

110°F

35°F

2°F Fixed

2°F Fixed

11B18-153

Well Immersion

Open on Rise 140

1127-2

Surface Mount

SPDT 141

240°F 100°F 10°F Fixed

Capillary Length

Switch Action

Page Number

240°F 100°F

45°F

7°F

1131-102

Well Immersion

SPDT 140

240°F 100°F

45°F

5°F

1145-33

Direct Immersion

Open on Rise 142

240°F 100°F

45°F

7°F

11A79-2

Direct Immersion

SPDT 142

11B02-1

Surface Mount

Open on Rise 141

Well Immersion

Close on Rise 140

240°F 100°F 10°F Fixed 10°F Fixed 240°F 100°F

45°F

5°F

11B05-101

240°F 100°F

45°F

5°F

11B06-1

240°F 100°F

45°F

5°F

11B18-101

Well Immersion

35°F 10°F

11C15-11

Dual Action

Low Limit 35°F Low Limit 10°F 11C30-3

Well Immersion

Remote Bulb

5 feet

Open on Rise 139 Open on Rise 140

240°F High Limit, 140°F High Limit, 200°F Circulator 100°F Circulator 240°F 140°F

High Limit



141



141

High Limit 10°F

240°F 100°F

45°F

5°F

11D18-1

Well Immersion

Open on Rise 140

240°F 100°F

45°F

7°F

11D31-1

Well Immersion

SPDT 140

240°F 100°F

45°F

7°F

11D82-1

240°F Limit 140°F Limit

8°F

8°F

8B48A-217

Well Immersion



143

240°F Limit 140°F Limit

8°F

8°F

8F48A-351

Well Immersion



143

240°F Limit 140°F Limit

8°F

8°F

8J48A-209

Well Immersion



143

➀ High Limit Open on Rise, Circulator Close on Rise ➂ Close on Rise – Open on Rise (Circulator -Limit)

Remote Bulb

5 feet

SPDT 139

➁ High Limit Open on Rise, Low Limit Open on Rise

www.white-rodgers.com

133

HYDRONIC

Range Max.

HYDRONIC CONTROLS

ZONE VALVES HYDRONIC ZONE CONTROLS

Two Types of Valves, 2-Wire or 3-Wire, for Zoning Hydronic Systems up to 50 PSI FEATURES • Quiet operation. • Valve stem made of stainless steel. • Automatic recycling manual operator shows valve position at all times. • Built-in auxiliary contacts to control burner or circulator relay. • Motor can be removed from valve assembly without draining system.

SPECIFICATIONS Electric rating of auxiliary switch . . . . . . . 2.0A at 24VAC Four zone valves operate with one 40 VA transformer

1311-102

CONTRACTOR TIP: FOR HEAT/COOL APPLICATIONS, SEE 752-1 CONTROL ON PAGE 137. DO NOT CHANGE VALVE ASSEMBLY WITHOUT DRAINING BOILER OR WHILE BOILER WATER IS HOT. FAILURE TO RELIEVE WATER PRESSURE OR WAIT UNTIL WATER COOLS COULD RESULT IN SCALDING INJURIES

PARTS AND ACCESSORIES

• F19-0097 — Motor assembly for 3-wire zone valves • F19-0104 — Motor assembly for 2-wire zone valves • F84-0433 — Valve assembly for 3/4” (both series) • F84-0434 — Valve assembly for 1” (both series) • F84-0435 — Valve assembly for 11/4” (both series) • F92-0227 — Water seal kits for 3/4” (both series) • F92-0228 — Water seal kits for 1” (both series) • F92-0229 — Water seal kits for 11/4” (both series)

VALVE DIMENSIONS (inches) SIZE

B

C

D

E

/4” 13/4

61/2

27/8

411/16

55/8

1” 115/16

63/4

31/8

413/16

57/8

11/4”

71/8

311/16

5

61/4



3

A

21/8

See end of this section for additional parts and accessories

?

TECHNICAL HELP Zone Valve Troubleshooting . . . . . . . . . . See pages 298-299

HYDRONIC

3-WIRE, 24V VALVES WITH SCREW TERMINAL WIRING PANEL AND AUXILIARY SWITCH (SEE TABLE AT BOTTOM FOR COMPATIBLE THERMOSTATS) Maximum Model 24VAC Thermostat Time Differential Number Tubing Size (I.D.) Circuit Rating Cycle Across Valve 3 1311-102 /4” 0.4A ➀ Open: 45 seconds 15 PSI Close: 45 seconds 1311-103 1” 0.4A ➀ Open: 45 seconds 15 PSI Close: 45 seconds 1311-104 11/4” 0.4A ➀ Open: 45 seconds 15 PSI Close: 45 seconds

Maximum Maximum Flow Water System Capacity Temp. Pressure Cv 240°F 50 PSI 23.5 ➂ (116°C) 240°F 50 PSI 37.0 ➂ (116°C) 240°F 50 PSI 42.2 ➂ (116°C)

Friction Loss Equivalents Ft. of Tubing

Maximum Maximum Flow Water System Capacity Temp. Pressure Cv 240°F 50 PSI 23.5 ➂ (116°C) 240°F 50 PSI 37.0 ➂ (116°C) 240°F 50 PSI 42.2 ➂ (116°C)

Friction Loss Equivalents Ft. of Tubing

21/2 3.5 6.5

2-WIRE, 24V VALVES WITH SCREW TERMINAL WIRING PANEL AND AUXILIARY SWITCH Maximum Model 24VAC Thermostat Time Differential Number Tubing Size (I.D.) Circuit Rating Cycle Across Valve 3 1361-102 /4” 0.2A ➁ Open: 45 seconds 15 PSI Close: 60 seconds 1361-103 1” 0.2A ➁ Open: 45 seconds 15 PSI Close: 60 seconds 1361-104 11/4” 0.2A ➁ Open: 45 seconds 15 PSI Close: 60 seconds

21/2 3.5 6.5

➀ Valve current is 0.4A only during opening or closing. For proper anticipation, select thermostat designed for use with a 3-wire zone valve. ➁ Valve current is 0.52A when opening but 0.2A when fully open: therefore set anticipator for 0.2A. ➂ GPM @ 1 PSI drop. 1311 COMPATIBLE THERMOSTATS TABLE

Model Number

Programming Options

Contacts

Profile

Terminals



1E35-910

Non-Programmable

Sealed Mercury Cell

Vertical

4, 5, 6



1F35-910

Non-Programmable

Sealed Mercury Cell Horizontal 4, R5, Y6



1F90-371

5+1+1, 5+2

Electronic

Horizontal RC, RH, W, Y, G, MV, O, B, +, S, -, 6



1F96-344

Non-Programmable

Electronic

Horizontal RC, RH, W, Y, G, MV, O, B, +, S, -, 6



1F97-371

7-Day

Electronic

Horizontal RC, RH, W, Y, G, MV, O, B, +, S, -, 6



1F95-1277 Touch Screen

7-Day, 5+1+1, or Non-Programmable

Electronic

Horizontal RC, RH, C, W/E, W2, Y, Y2, G, O, B, 6, L, +, S, -



1F97-1277 Touch Screen

7-Day, 5+1+1, or Non-Programmable

Electronic

Horizontal RC, RH, C, W, Y, G, O, B, W/E, L, 6, +, S, -



1F97-391

7-Day

Electronic

Horizontal RC, RH, W, Y, G, 6, HM1, HM2, S1, S2, S3



1F80-0471

5+1+1, 5+2, or Non-Programmable

Electronic

Horizontal RC, RH, C, W, Y, G, O/B



1F86-0471

Non-Programmable

Electronic

Horizontal RC, RH, C, W, Y, O/B

134

www.white-rodgers.com

HYDRONIC CONTROLS

ZONE VALVES DIRECT-CONNECT TYPE – sweat and npt models FEATURES

13S16-102

F19-0737 ZRPLMTR1 Replacement Motor with Bracket

• Lever for manual open (normally closed valves only). • Auxiliary switch (optional). • Return spring design – stainless steel for long life. • Plastic molded cover provides extra protection from moisture. • Swing-type ball valve made from EPDM (Ethylene Propylene Polymer). – Rotating design results in less wear on valve. – Raised ball design ensures positive valve closure and even surface wear. • Valve body & crank arm assemblies each made from one-piece cast brass construction. • Gears made from heavy 14 gauge brass for durable long life. • Valve assembly design includes a recessed “O” ring for positive sealing.

SPECIFICATIONS Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 24 VAC Frequency . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz Connection . . . . . . . . . . . . . . . . . . . . . . 18” leads Flow Capacity . . . . . . . . . . . . . . . . . . . . 3.5 Cv Close-off Pressure . . . . . . . . . . . . . . . . . 20 PSI Maximum Pressure . . . . . . . . . . . . . . . . 142 PSI Maximum Temperature . . . . . . . . . . . . . 110°C (230°F) Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . Electric synchronous, spring return Positioning . . . . . . . . . . . . . . . . . . . . . . . 2-way, straight through

PARTS AND ACCESSORIES

• F19-0737 & ZRPLMTR1 — Replacement motor with bracket

Model Number 13S16-101 13S16-102 13S05-102 13S16-103 13SH16-102 13SH16-103



Canada Flow Model Pipe Pipe Auxiliary Capacity Number Connection Size Switch Cv ➁ 1 ZSW12NCA Sweat /2” Yes 3.5 3 ZSW34NCA Sweat /4” Yes 3.5 3 ZSW34NO Sweat /4” No 3.5 ZSW1NCA Sweat 1” Yes 3.5 3 – Sweat /4” Yes 7.0 ZSW1NCA7C Sweat 1” Yes 7.0

De- Honeywell Energized Cross Position Reference NC V8043G1000, V8043E1004 NC V8043G1018, V8043E1012 NO V8043D1064, V8043B1027 NC V8043G1026, V8043E1020 NC – NC V8043G1158 ➀, V8043E1079 ➀



De- Energized Position NC NO NC NC NO NC NC NC

Erie Cross Reference VT2213G13A02A VT2213G13A02A VT2213G23A020 VT2415G13A02A – VT2417G13A02A ➀

NPT Model Number 13N16-101 13N05-101 13N16-102 – – 13N16-103 13NH16-102 13NH16-103

Canada Flow Model Pipe Pipe Auxiliary Capacity Number Connection Size Switch Cv ➁ 1 ZNPT12NCA NPT /2” Yes 3.5 1 ZNPT12NO NPT /2” No 3.5 3 ZNPT34NCA NPT /4” Yes 3.5 3 ZNPT34NC NPT /4” No 3.5 3 ZNPT34NO NPT /4” No 3.5 ZNPT1NCA NPT 1” Yes 3.5 3 – NPT /4” Yes 7.0 ZNPT1NCA7C NPT 1” Yes 7.0

Honeywell Cross Reference – – V8043G1109, V8043E1145 – V8043B1076, V8043O1031 – – –

Erie Cross Reference VT2223G13A02A VT2223G23A020 VT2323G13A02A – VT2323G23A02O VT2427G13A02A – –

➀ Valve is 8.0 Cv ➁ GPM @ 1 PSI drop

13A00 CROSS REFERENCE

13A01-101 13A01-102 13A02-101 13A02-102 13A03-112

13S16-101 13S16-102 13S16-101 13S16-102 13S16-102

Replacement has Auxiliary Switch and No Conduit Hub Replacement has Leads Instead of Push-In Terminals Replacement has No Conduit Hub

 Indicates Canadian Model Number: call 1-800-305-6953 to order www.white-rodgers.com

135

HYDRONIC

SWEAT

HYDRONIC CONTROLS

ZONE VALVES

ADAPTER TYPE – FLARE AND INVERTED FLARE MODELS FEATURES • Lever for manual open (normally closed valves only). • Auxiliary switch (optional). • Return spring design – stainless steel for long life. • Plastic molded cover provides extra protection from moisture. • Swing-type ball valve made from EPDM (Ethylene Propylene Polymer). – Rotating design results in less wear on valve. – Raised ball design ensures positive valve closure and even surface wear. • Valve body & crank arm assemblies each made from one-piece cast brass construction. • Gears made from heavy 14 gauge brass for durable long life. • Valve assembly design includes a recessed “O” ring for positive sealing.

13F05-100

Inverted Flare Sweat Adapter

Flare Sweat Adapter

SPECIFICATIONS Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 24 VAC Frequency . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz Connection . . . . . . . . . . . . . . . . . . . . . . 18” leads Flow Capacity . . . . . . . . . . . . . . . . . . . . 3.5 Cv Close-off Pressure . . . . . . . . . . . . . . . . . 20 PSI Maximum Pressure . . . . . . . . . . . . . . . . 142 PSI Maximum Temperature . . . . . . . . . . . . . 110°C (230°F) Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . Electric synchronous, spring return Positioning . . . . . . . . . . . . . . . . . . . . . . . 2-way, straight through

PARTS AND ACCESSORIES

• F19-0737 & ZRPLMTR1 — Replacement motor with bracket

HYDRONIC

INVERTED FLARE Model Number 13V16-101 13V06-101



Canada Flow Model Pipe Pipe Auxiliary Capacity Number Connection Size Switch Cv ➁ 1 ZINV12NCA Inverted Flare /2” Yes 3.5 1 ZINV12NOA Inverted Flare /2” Yes 3.5

De- Energized Position NC NO

Honeywell Cross Reference V8043G1125, V8043E1129 –

De- Energized Position NO NC NC NO NC

Honeywell Cross Reference V8043D1197 V8043C1116, V8043A1003 V8043G1133 V8043D1080 V8043C1033

Erie Cross Reference VT2343G13A02A VT2343G23A02A

INVERTED FLARE SWEAT ADAPTERS

Model Number Z12ADINV Z1ADINV Z34ADINV

Description Accessory 1/2” Zone Valve Inverted Flare Sweat Adapter Accessory 1” Zone Valve Inverted Flare Sweat Adapter Accessory 3/4” Zone Valve Inverted Flare Sweat Adapter

FLARE Model Number 13F05-100 13F15-100 13F16-100 13FA05-100 13FA15-100



Canada Flow Model Pipe Pipe Auxiliary Capacity Number Connection Size Switch Cv ➁ 3 ZFL38NO Flare /8” No 3.5 3 ZFL38NC Flare /8” No 3.5 3 ZFL38NCA Flare /8” Yes 3.5 3 ZFL38NO-34AD ➀ Flare /8” No 3.5 3 ZFL38NC-34AD ➀ Flare /8” No 3.5

➀ Includes (2) 3/4” sweat adaptors ➁ GPM @ 1 PSI drop

FLARE SWEAT ADAPTERS

Model Number Z12ADFL Z1ADFL

Description Accessory 1/2” Flare Sweat Adapter Accessory 1” Flare Sweat Adapter

 Indicates Canadian Model Number: call 1-800-305-6953 to order 136

www.white-rodgers.com

Erie Cross Reference VT2253G23A020 VT2253G13A020 VT2253G13A02A VT2253G23A0200F VT2253G13A0200F

REMOTE TEMPERATURE CONTROLS SPDT TEMPERATURE CONTROLS

For Remote Control of Combination Heating-Cooling Installations. Ideal for use as Outdoor Thermostat or Changeover Control FEATURES • Hydraulic action element – No leveling required. • Switch case mounts in any position. Bulb mounting clamp included. • Dustproof steel case – Dial visible and can be adjusted through cover. Case has knockouts on top and bottom. • Temperature dial graduated in °F and °C. • Easy to wire screw terminals.

SPECIFICATIONS

1687-9

Dimensions . . . . . . . . . . . . . . . . . . . . . . . 53/8”H x 25/16”W x 29/16”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed

Model Capillary Bulb Switch Number Range Differential Length Size Action 445-6 20 to 90°F Adj. 4 to 20°F 5 ft. 67/8” x 3/8” SPDT (–6 to +32°C) (2 to 11°C) 3 3 1687-9 –30 to 90°F Adj. 4.5 to 40°F 8 ft. 5 /16” x /8” SPDT (–34 to +32°C) (2.5 to 22°C)

Full Motor Electrical (Full Load) Rating 120 VAC 240 VAC SPDT 7.4A 3.7A see p. 416

SPDT

7.4A

3.7A

see p. 416

SPDT Contact Structure SPDT Rated Controls Switch Action R-B Open on Rise R-W Close on Rise

SPDT Control Provides Automatic Change-Over of Thermostat to Operate Zone Valve on Combination Hot and Chilled Water Systems FEATURES • Epoxy resin seal protects bimetallic disc and Snap-Action contacts from dust, dirt and corrosion. • Furnished with removable spring clip to attach control to tubing. • SPDT switch connects heating side of thermostat to two-wire zone valve when hot water is circulated through tubing. • SPDT switch connects cooling side of thermostat to two-wire zone valve when chilled water is circulated through tubing. • Curved sensing element provides maximum contact with tubing.

SPECIFICATIONS Electrical Connections . . . . . . . . . . . . . . . 12” red, brown and black leads,

752-1 CONTRACTOR TIP: USE WITH ZONE VALVES ON PAGE 134 FOR heat/cool applications.

105°C insulated, No. 18 wire

Temperature Settings . . . . . . . . . . . . . . . Red-Black: open on rise @ 85°F, close @ 70°F Red-Brown: close on rise @ 85°F, open @ 70°F Ambient Temperature . . . . . . . . . . . . . . . 221°F maximum

TYPES FOR USE WITH ½” TUBING (5/8” O.D.) Model Number without conduit conn. 752-1

Model Number with conduit Switch connector Action 752-2 SPDT

Motor Rating Pilot Duty Resistive Full Load Lock Rotor 120/240/ (non-inductive) 120 VAC 240 VAC 120 VAC 240 VAC 277 VAC 120/240/277 VAC 7.5A 3.75A 45.0A 22.5A 125 VA 15A

www.white-rodgers.com

137

HYDRONIC

AUTOMATIC CHANGE-OVER SWITCH

ELECTRIC WATER HEATER THERMOSTATS UNIVERSAL REPLACEMENTS FOR ELECTRIC WATER HEATER THERMOSTATS AND LIMITS Surface Mount Temperature Sensing Controls FEATURES • High electrical capacity. • Snap-Action contact. • Long life-proven reliability. • Adjustable control or manual reset styles.

SPECIFICATIONS 754-1

Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. and C.S.A. recognized

Model Switch Number Description Action Range 754-1 DPST limit (manual reset) Open on Rise 170°F fixed (77°C) 755-1 SPST thermostat Open on Rise 90 to 150°F(32 to 66°C) 755-50 754-1 + 755-1 – – 756-1 SPDT thermostat Open 1-2 on Rise 90 to 150°F(32 to 66°C) 756-50 754-1 + 756-1 – – SPDT thermostat Open 1-2 on Rise 90 to 170°F(32 to 77°C)  756-2

120/240 VAC – 30.0A 30.0A 30.0A 30.0A 30.0A

A.C. Electrical Ratings (Non-Inductive) 277 VAC 480 VAC 40.0A 25.0A 25.0A 12.5A 25.0A 12.5A 25.0A 12.5A 25.0A 12.5A 25.0A 12.5A

755-1

HYDRONIC

755-50

756-50

 Indicates Canadian Model Number: call 1-800-305-6953 to order

138

www.white-rodgers.com

756-1

HYDRONIC CONTROLS REMOTE BULB TYPES

Regulate Temperature of Any Liquid Non-Corrosive to Copper in Applications such as Vats, Hot Water Boilers, DeFeathering Tanks, Oil Filtering, etc. Available in Open or Close On Rise Types for use as High Limit or Reverse Acting Control. FEATURES • Capillary permits convenient mounting of control regardless of well position. • Dial evenly calibrated in °F and °C for exact setting. • Special screw terminals with “ears” securely hold solid and stranded wires. • Dustproof steel case.

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 53/4”H x 25/16” W x 29/16”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. certified

PARTS AND ACCESSORIES • F55-0088 — Packing nut ½ thread, for use with remote bulb • F145-0650 — Well adapter and heat conductive compound • F71-0924 — Well adapter only • F145-0163 — Tube heat conductive compound • For immersion wells, see page 147.

Full Model Switch Electrical Number Range Differential Action Rating 11B06-1 ➀ 100 to 240°F 5 to 45°F Open on Rise HTV (38 to 116°C) (3 to 25°C) See page 416 11D82-1 100 to 240°F 7 to 45°F SPDT SPDT (38 to 116°C) (4 to 25°C) See page 416 Fixed 5°F Open on Rise HTV  11B06-46 100 to 400°F (38 to 204°C) (3°C) See page 416 Fixed 45°F Open on Rise —  11B95-31 195°F (91°C) (25°C) 120 to 180°F 4°F Open on Rise — (50 to 82°C) (2°C)

Motor Rating Valves and Bulb Capillary (Full Load) Relays Size Length 120 VAC 240 VAC 24 VAC 0.3-12v DC 31/2 x 7/16” 5 FT. 10.0A 6.0A 6.0A 1.0A 31/2 x 3/8” 5 FT. 7.4A 3.7A 2.9A — 6” x 1/4” 5 FT. 10.0A 6.0A 6.0A 1.0A Stainless Steel 23/4 x 45/8 - — 10.0A — .75A 0.25-1v DC 3 4 / ” NPT .25A 3 4 / ” NPT 50” 10.0A — .75A 0.25-1v DC Comp Fitting .25A

➀ With armored capillary and U.L. approved adjustable dial stop, factory set at 180°F maximum.

SPDT Contact Structure HH Rated Controls Switch Action R-B Open on Rise R-W Close on Rise

CONTRACTOR TIP: TESTING AUTOMATIC TEMPERATURE CONTROLS To verify a control is opening and closing properly, disconnect all power before testing. Testing must be performed with the sensing element at a temperature within the setting range of the control. For most hydronic controls with a range of 100 to 240°F, a pan of hot water is sufficient to reach the control range. Attach an ohmmeter or continuity tester across the Open on Rise contacts. Lower the temperature setting dial to the lowest setting. If the lowest setting is below the temperature of the sensing element minus the differential of the control, the contacts should be open. Raise the temperature dial slowly. When the setting is raised above the temperature of the sensor, the contacts should close.

 Indicates Canadian Model Number: call 1-800-305-6953 to order www.white-rodgers.com

139

HYDRONIC

11D82-1

HYDRONIC CONTROLS WELL IMMERSION SINGLE CONTROL

Types for use as High Limit, Reverse Action or SPDT Switching Action: May Be Mounted Either Horizontal or Vertical. FEATURES • Extra capillary length for extended shank wells. • Special screw terminals with “ears” securely hold solid and stranded wires. • Screwdriver-adjustable differential with direct-read indicator. • Knockouts on top and bottom and plenty of wiring room. • Hydraulic action element — fast acting.

11D18-1

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 53/8”H + 25/16” coil x 29/16”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. certified

PARTS AND ACCESSORIES

See end of this section for additional parts and accessories

• F145-0163 — Tube heat conductive compound • F145-0650 — Well adapter and heat conductive compound • F71-0924 — Well adapter only • Immersion wells — see page 147 TYPES WITH BULBS DIRECTLY INTERCHANGEABLE WITH HONEYWELL (39/16” x 3/8”) No wells included. Model Switch Number Range Differential Action 11D18-1 ➀ 100 to 240°F 5 to 45°F Open on Rise (38 to 116°C) (3 to 25°C) 11D31-1 100 to 240°F 7 to 45°F SPDT (38 to 116°C) (4 to 25°C)

Full Motor Rating Valves and Electrical (Full Load) Relays Rating 120 VAC 240 VAC 24 VAC 0.3-12v DC HTV 10.0A 6.0A 6.0A 1.0A See page 416 HH 7.4A 3.7A 2.9A — See page 416

➀ Has U.L. approved adjustable dial stop, factory set at 150°F maximum.

HYDRONIC

TYPES WITH TAPERED BULBS (27/16” x 7/16”) All types include 1/2” standard shank well, unless otherwise specified. Model Switch Number Range Differential Action 1131-102 ➀ 100 to 240°F 7 to 45°F SPDT (38 to 116°C) (4 to 25°C) 11B05-101 100 to 240°F 5 to 45°F Close on Rise (38 to 116°C) (3 to 25°C) 11B18-101 ➀ 100 to 240°F 5 to 45°F Open on Rise (38 to 116°C) (3 to 25°C) 11B18-153 ➁ 35 to 110°F Fixed 2°F Open on Rise (2 to 43°C) (1°C) 11B27-9 ➂ 100 to 500°F Manual Open on Rise  (40 to 260°C) Reset 11B27-10 ➂ 250 to 650°F Manual Open on Rise  (121 to 343°C) Reset 11B30-104 ➃ 100 to 240°F 8 to 45°F Open on Rise  (38 to 116°C) (4.5 to 25°C) ➀ Has U.L. approved adjustable dial stop, factory set at 150°F maximum. ➁ Has special straight well for 4” x 7/16” straight bulb. ➂ Has 7’ capillary and 3” x 5/16” straight bulb. ➃ 3/4” standard shank well.

 Indicates Canadian Model Number: call 1-800-305-6953 to order

Full Electrical Rating HH

Motor Rating (Full Load)

Valves and Relays

240 VAC 24 VAC 0.3-12v DC 7.4A 3.7A 2.9A — See page 416 HT 14.0A 7.0A — — See page 416 HTV 10.0A 6.0A 6.0A 1.0A See page 416 HTV 10.0A 6.0A 6.0A 1.0A See page 416 FG 14.0A 7.0A 5.6A — See page 416 FG 14.0A 7.0A 5.6A — See page 416 HTV 10.0A 6.0A 6.0A 1.0A 120 VAC

See page 416

SPDT Contact Structure HH Rated Controls Switch Action R-B Open on Rise R-W Close on Rise

CONTRACTOR TIP: TESTING AUTOMATIC TEMPERATURE CONTROLS To verify a control is opening and closing properly, disconnect all power before testing. Testing must be performed with the sensing element at a temperature within the setting range of the control. For most hydronic controls with a range of 100 to 240°F, a pan of hot water is sufficient to reach the control range. Attach an ohmmeter or continuity tester across the Open on Rise contacts. Lower the temperature setting dial to the lowest setting. If the lowest setting is below the temperature of the sensing element minus the differential of the control, the contacts should be open. Raise the temperature dial slowly. When the setting is raised above the temperature of the sensor, the contacts should close. 140

www.white-rodgers.com

HYDRONIC CONTROLS DUAL ACTION – SINGLE ELEMENT CONTROLS

Designed to Replace Any Immersion Type Hot Water Control – High Limit, Low Limit or High-Low Limit/Circulation Combination FEATURES • Dual action controls use a single hydraulic action element to operate two precision snap switches. • Dustproof steel case with top and bottom knockouts and snap-on cover. • Large screw terminals and ample wiring space. • Extra capillary for standard or extended shank well. (Shipped without well. Except 11C30-3)

11C15-11 Terminal Panel

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 41/16”H x 33/4”W x 25/16”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. certified

PARTS AND ACCESSORIES

See end of this section for additional parts and accessories

• F145-0650 – Well adapter and heat conductive compound • F71-0924 – Well adapter only • F145-0163 – Tube heat conductive compound • For immersion wells, see page 147 Motor Rating Model Switch (Full Load) Number Range Differential Action 120 VAC 240 VAC 11C15-11 High Limit: 140 to 240°F (60 to 116°C) Adj. 10 to 35°F Open on Rise 8.0A 6.0A Circulator: 100 to 200°F (38 to 93°C) (6 to 19°C) Close on Rise 8.0A 6.0A 11C30-3 High Limit: 140 to 240°F (60 to 116°C) Fixed 10°F (6°C) Open on Rise 8.0A 6.0A Low Limit: 140 to 240°F (60 to 116°C) Adj.10 to 35°F (6 to 19°C) High Limit: 100 to 240°F (45 to 116°C) Fixed 5°F (3°C) Open on Rise 10.0A 6.0A  11B54-4 Low Limit: 60 to 110°F (16 to 43°C) Fixed 3°F (1.5°C) High Limit: 140 to 240°F (60 to 116°C) Adj. 10 to 35°F Open on Rise 8.0A 6.0A  11C61-12 Low Limit: 100 to 200°F (38 to 93°C) (6 to 19°C) SPDT

Valves and Relays 120 VAC

240 VAC

3.2A 3.2A –

0.25A – 0.25A

6.0A 1.0A –

0.25A

HYDRONIC

SURFACE (STRAP-ON) TYPES

Attach Directly to Surface of Pipe. Types for use as High Limit, Reverse Acting or SPDT Switching Action Control. FEATURES 1127-2

SPDT Contact Structure HH Rated Controls Switch Action R-B Open on Rise R-W Close on Rise

• Sensing element has twice the contact area of competitive models. • Hydraulic action element can be mounted in any position — no leveling required. • Dustproof steel case. • Special screw terminals with “ears” securely hold solid and stranded wires. • Includes pipe strap and mounting screws.

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 67/8”H (includes plate) x 25/16” W x 33/16”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. certified

Full Motor Rating Valves and Model Switch Electrical (Full Load) Relays Number Range Differential Action Rating 120 VAC 240 VAC 24 VAC 0.3-12v DC 11B02-1 ➀ 100 to 240°F Fixed 10°F Open on Rise HTV 10.0A 6.0A 6.0A 1.0A (38 to 116°C) (5.5°C) See page 416 1127-2 ➁ 100 to 240°F Fixed 10°F SPDT HH 7.4A 3.7A 2.9A — (38 to 116°C) (5.5°C) See page 416 60 to 200°F Fixed 15°F SPDT HH 7.4A 3.7A 2.9A —  1127-9 (16 to 93°C) (8°C) See page 416 ➀ Has U.L. approved adjustable dial stop, factory set at 220°F maximum.  Indicates Canadian Model Number: call 1-800-305-6953 to order ➁ Has U.L. approved adjustable dial stop, factory set at 150°F maximum. www.white-rodgers.com

141

HYDRONIC CONTROLS FAST RESPONSE DIRECT IMMERSION CONTROLS

1145-33 Control has Thermal Element Immersed Directly in the Water for use as a High Limit and/or Operating Control. 11A79-2 for Immersion Directly in the Boiler Water. Use as a High Limit, Low Limit, Circulator Control or Combination Low Limit and Circulator Control. FEATURES

1145-33

• Specially designed hydraulic action element for fast response to temperature change. • Temperature dial calibrated in °F and °C and can be adjusted through cover. • Control mounts in any position without affecting performance. • 3/4” bushing furnished with each control.

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . (1145-33) 53/8”H x 25/16”W x 17/8”D (11A79-2) 53/8”H x 25/16”W x 17/8”D Bulb Extensions . . . . . . . . . . . . . . . . . . . . Element has 1/2” pipe threads (1145-33) 113/16”beyond threads (11A79-2) 33/8”beyond threads Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. certified

PARTS AND ACCESSORIES

See end of this section for parts and accessories

HYDRONIC

11A79-2

Model Switch Number Range Differential Thread Size Action 1145-33 ➀ 100 to 240°F 5 to 45°F ½” Open on Rise (38 to 116°C) (3 to 25°C) 11A79-2 ➁ 100 to 240°F 7 to 45°F ½” SPDT (38 to 116°C) (4 to 25°C)

Full Motor Rating Valves and Electrical (Full Load) Relays Rating 120 VAC 240 VAC 24 VAC 0.3-12v DC HTV 10.0A 6.0A 6.0A 1.0A See page 416 HH 7.4A 3.7A 2.9A — See page 416

➀ Dial has U.L. approved adjustable stop, factory pre-set at 185°F (85°C) maximum setting. ➁ Dial has U.L. approved adjustable stop, factory pre-set at 220°F maximum.

CONTRACTOR TIP: TESTING AUTOMATIC TEMPERATURE CONTROLS To verify a control is opening and closing properly, disconnect all power before testing. Testing must be performed with the sensing element at a temperature within the setting range of the control. For most hydronic controls with a range of 100 to 240°F, a pan of hot water is sufficient to reach the control range. Attach an ohmmeter or continuity tester across the Open on Rise contacts. Lower the temperature setting dial to the lowest setting. If the lowest setting is below the temperature of the sensing element minus the differential of the control, the contacts should be open. Raise the temperature dial slowly. When the setting is raised above the temperature of the sensor, the contacts should close.

142

www.white-rodgers.com

HYDRONIC CONTROLS COMBINATION HIGH LIMIT/SWITCHING RELAY CONTROLS

Replacement Controls for Hot Water Systems Where Boiler Does Not Supply Domestic Hot Water FEATURES • High limit and circulator relay combined in one case and wired to terminal panel. • Knockouts on top and bottom — plenty of wiring room. • Can be used on systems zoned with circulators (8B48A) or zone valves (8J48A). • Dustproof steel case with cover. • 8J48A-209 has 30 VA transformer for external power (zone valves).

SPECIFICATIONS

8B48A-217

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Vertical — 61/4”H x 43/8” W x 31/8”D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Horizontal — 43/8”H x 61/4” W x 31/8”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Switch Action . . . . . . . . . . . . . . . . . . . . . . . . Open on rise Input Voltage (60 Hz) . . . . . . . . . . . . . . . . . . 120 VAC Thermostat Current . . . . . . . . . . . . . . . . . . . 0.26A Maximum sensing element temperature . . . 260°F (127°C) Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. recognized

PARTS AND ACCESSORIES

See end of this section for additional parts and accessories

• F145-0650 — Well adapter and heat conductive compound • F71-0924 — Well adapter only • F145-0163 — Tube heat conductive compound • For immersion wells, see page 147

TECHNICAL HELP

Circulator Ignition Model Burner Motor Transformer Number Control Voltage Range Differential 120 VAC 120 VAC Burner 8B48A-217 Line (120 VAC) 140 to 240°F Fixed 8°F 7.4 FLA, 44.4 LRA 3.0A ➅ 7.4 FLA, 44.4 LRA (60 to 116°C) (4.5°C) 8F48A-351 Low (24 VAC) 140 to 240°F Fixed 8°F 8.0 FLA, 48.0 LRA — 0.65A, 24 VAC (60 to 116°C) (4.5°C) 8J48A-209 Millivolt or Low 140 to 240°F Fixed 8°F 8.0 FLA, 48.0 LRA — 0.25A, .25 to 1v DC, (24 VAC) (60 to 116°C) (4.5°C) or 0.65A, 24 VAC

External Power None

Bulb Size 3 x 3/8”

Accessories ➀➂

Yes – 30 VA

2 x 3/8”

➂➃➄

Yes – 30 VA

3 x 3/8”

➀➁➂

@ 24 VAC

➀ Includes well adapter and heat transfer compound (grease). ➁ Includes manual switch (AUTO-ON) which will energize burner circuit with system power off/on millivolt system. ➂ Includes terminals for adding SPDT low limit/circulator control. ➃ Shipped with ¾” NPT extended shank well. ➄ Plug in harness for vent damper. ➅ Total connected load 2000 VA maximum.

www.white-rodgers.com

143

HYDRONIC

Wiring Diagram 8F48A, 8J48A . . . . . . . . See pages 296-297

HYDRONIC CONTROLS COMBINATION HIGH LIMIT/LOW LIMIT-CIRCULATOR SWITCHING RELAY CONTROL Replacement for the Control of Hot Water Systems Where Boiler also Provides Domestic Hot Water FEATURES • Clearly marked terminal panel for thermostat, circulator and burner circuits. • Knockouts top and bottom — Plenty of wiring room. • Can be used on systems zoned with circulators or water valves. • Maintains low limit temperature for domestic hot water.

SPECIFICATIONS

8B43A-601

Dimensions . . . . . . . . . . . . . . . . . . . . . . . 53/8”H x 61/8”W x 31/8”D Switch Action . . . . . . . . . . . . . . . . . . . . . . High Limit: Open on rise Low Limit: Circulator SPDT Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Input Voltage (60 Hz) . . . . . . . . . . . . . . . . 120 VAC Thermostat Current . . . . . . . . . . . . . . . . . 0.25A at 24V Maximum Element Temperature . . . . . . . 260°F (127°C)

PARTS AND ACCESSORIES

See end of this section for parts and accessories

24 VAC Burner External Circulator External Load Model Control Power Bulb Motor Motorized Number Voltage Range Differential @ 24 VAC Size Burner 120 VAC Gas Zone Valve Low High: 140 to 240°F (60 to 116°C) Fixed 10°F (5.5°C) Yes 27/8” x 3/8” 0.65A, 6.0 FLA, ➀ 0.65A ➀ 30 VA running  8B43A-601 (24 VAC) Low: 100 to 200°F (38 to 93°C) Adj. 10 to 35°F (5.5 to 19°C) 30VA 24 VAC 48 LRA 45 VA inrush NOTE: Total connected load 2000VA. ➀ Dial has U.L. approved adjustable stop, factory pre-set at 220°F maximum.

HYDRONIC

WIRING INFORMATION The diagram below shows wiring connections for a typical oil-fired installation. Operation is as follows: When the room thermostat is not calling for heat, the low limit-circulator control operates the burner motor as necessary to maintain the domestic hot water supply at the desired temperature (burner “on” when R-B contacts are closed). When the room thermostat closes its contacts, the relay coil is energized and closes its two sets of relay contacts. The burner starts as the No. 1 Relay Contacts close. If the R-W contacts of the low limit-circulator control are closed, the circulator motor also starts as the No. 2 Relay Contacts close. If the R-W contacts open while the thermostat is calling for heat, the circulator motor stops but the burner stays on. When the room thermostat is satisfied, the circulator motor stops as the No. 2 Relay Contacts open. The burner motor also stops as the No. 1 Relay Contacts open, unless the R-B contacts of the low limit-circulator are closed. If boiler temperature exceeds the setting of the high limit, the burner motor stops. If thermostat is calling for heat, the circulator continues to run.

external wiring

Line Voltage

Low Voltage

Low Voltage

low voltage thermostat

transformer

hot

T1

1

line N

2

 Indicates Canadian Model Number: call 1-800-305-6953 to order 144

Internal wiring

Line Voltage

www.white-rodgers.com

#1 relay contact

low limit-circ. control S1

B

R

ZC

W

relay coil

high limit Z

S2

ZC

T2

Type 668 oil burner control (line voltage) ignition trans.

#2 relay contact C1

B1

C2

B2

burner motor circulator motor

RELAY TRANSFORMERS RELAY/TRANSFORMER COMBINATIONS

DPST Relay Models Enclosed with a Transformer Capable of Powering External Loads up to 35VA. Ideal for use on Boilers without Domestic Coil. Equally Adaptable for Zoned and Unzoned Systems FEATURES • Low voltage screw terminals — 3 color coded, end stripped line voltage leads. • Internal transformer can power up to 35VA external loads. • Mounts to 4”x 4” junction box. • Dustproof steel case.

8A05A-101

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 41/4”H x 23/4”W x 23/4”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Mounting . . . . . . . . . . . . . . . . . . . . . . . . . To 4” x 4” junction box Lead length . . . . . . . . . . . . . . . . . . . . . . . 8 inches Transformer . . . . . . . . . . . . . . . . . . . . . . . 35 VA maximum connected external load Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. recognized and C.S.A. certified

Model Thermostat Number Input Voltage Switch Action Current

 8A05A-4 120 VAC, 60 Hz  8A05A-101 120 VAC, 60 Hz

DPST SPDT

Contact Ratings Motor Rating 120 VAC Full Locked Load Rotor

0.28A 10.0A/16.0A 0.13A 8.0A/14.0A

Valves & Relays Terminals V1 & V2 30 VAC

0.3-12v DC

– –

– –

60.0A/96.0A 48.0/84.0A

universal replacement line voltage switching relays

For Controlling Line Voltage Loads with a Low Voltage Circuit • Case size switching function & terminal identification similar to competitive models. • “In-Line” line voltage terminal layout speeds wiring. • Full 10 amp load rating for increased flexibility. • Line voltage knockouts top and bottom. • Plastic grommet in low voltage knockout.

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 51/4”H x 41/4”W x 27/8”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Semi-gloss grey Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. certified

809A-189 Model Number Input Voltage Switch Action 809A-189 ➀ 120 VAC, 60 Hz SPST 829A-832 ➁ 120 VAC, 60 Hz DPST ➁ 829A-845 120 VAC, 60 Hz DPST

Thermostat Motor Ratings – Full Load Current 120 VAC 240 VAC 0.3A 10.0A 6.0A 0.3A 8.0A 4.0A 0.3A 10.0A 6.0A

Motor Ratings – Locked Rotor 120 VAC 240 VAC 60.0A 36.0A 48.0A 24.0A 60.0A 36.0A

➀ For 2- or 3-wire (series 10) thermostats. ➁ One set of contacts with two terminals for line voltage, one set of contacts for low (30 VAC) or millivolt circuits. “xx” contacts — 0.3 - 12v DC maximum — 1 amp maximum or 30 VAC maximum at 1 amp.

 Indicates Canadian Model Number: call 1-800-305-6953 to order www.white-rodgers.com

145

HYDRONIC

FEATURES

HYDRONIC CONTROLS ADJUSTABLE INDOOR-OUTDOOR CONTROL

Cuts Fuel Costs and Provides Utmost Comfort Performance from Conventional Hot Water Heating Systems: Ideal for Zoned Systems FEATURES • Fully adjustable reset ratio covers all climate conditions and eliminates stocking controls with different reset ratios. Replaces all three T475A Honeywell models. • Well-insertion bulb monitors boiler water temperature, outdoor bulb monitors outdoor temperature. Control modulates water temperature based on reset ratio selected. • Hydraulic action element — unaffected by vibration or moisture. • Mounting clamp for outdoor bulb included. • F89-0148 well included with control.

SPECIFICATIONS Dimensions . . . . . . . . . . . . . . . . . . . . . . . 9”H x 31/2”W x 4”D Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grey Capillary Length . . . . . . . . . . . . . . . . . . . . 15 feet to inside bulb 30 feet to outside bulb Thread Size . . . . . . . . . . . . . . . . . . . . . . . 1/2” pipe thread

1050-1

Model Switch Number Differential Action 1050-1 Fixed 10°F Open on Rise (5°C)

Full Motor Rating Electrical (Full Load) Rating 120 VAC 240 VAC FG 14.0A 7.0A see page 416

RESET RATIOS (OUTDOOR TO INDOOR)

Example: For 1.5 to 1 ratio, each 1.5°F drop in outdoor temperature will cause 1°F rise in boiler water.

HYDRONIC

B

Reset Square Dial Ratio Setting 1.5 to 1 1 1 to 1 2.5 1 to 1.5 4.5

SELECTING SQUARE DIAL SETTING (Round dial set at “N”)

Outdoor Design Temperature 20°F (– 7°C) 3 A 10°F (– 12°C) 2.5 0°F (– 17°C) 2 – 10°F (– 23°C) 1.5 – 20°F (– 29°C) 1 140 C A. Round dial adjusts comfort level required.

4.5 3.5 3 2.5 2 160

Suggested Square Dial Setting – – – 5 – – 4 5 – 3.5 4.5 5 3 4 4.5 180 200 220 Boiler Design Temperature °F

B. Square dial adjusts for heat-loss of specific installation. C. Adjustment screw for changing setting of square dial.

Charts 1, 2 and 3 above show the effect dial settings have on the operating water temperature under varying conditions. The installation setting of the square (heat-loss ratio) dial can be estimated from the table above. Some installations may require minor additional adjustments when first severe weather is encountered. • If area is too cool at low outdoor temperatures, raise square dial setting. • If area is too warm at low outdoor temperatures, lower square dial setting. • If area is too warm or too cool at all outdoor temperatures, then adjust round dial — cooler or warmer.

146

www.white-rodgers.com

– – – – 5 240

HYDRONIC CONTROLS IMMERSION WELLS AND PACKING NUT

½” and ¾” NPT Sizes for Hydronic Element Insertion FEATURES • Wells are used where it is desired that the control operates from the temperature of a liquid in a closed system. • The bulb of the control can be removed from an immersion well in the tank wall without draining the boiler tank. • The packing nut can be used with any of the remote bulb types listed. • Packing nuts permit closer control than wells because the bulb is directly immersed in the liquid.

SPECIFICATIONS Compatibility . . . . . . . . . . . . . . . . . . . . . . For use in liquids that are not corrosive to brass and copper. Not recommended for use above 100 psi, 250°F (120°C) PACKING NUT Model Number Description F55-0088

Tank wall shank

Fig. 2

Figure Number

Packing nut with ½” threads 1

UNIVERSALLY INTERCHANGEABLE WELLS Model Number F89-0211 F89-0212 F89-0213 F89-0214 F89-0215

Basic Types Bulb Size Well Is of Used With Control Used 1 2 All 3 / x 3/8” All 31/2 x 3/8” All 31/2 x 3/8” All 31/2 x 3/8” All 31/2 x 3/8”

Well Description Pipe Size Figure Dimensions NPT Shank Number A B C 1 2 / ” Standard 2 113/16” 3” 35/16” 1 2 / ” Std. Extended 2 35/16” 3” 35/16” 3 4 / ” Standard 2 113/16” 3” 35/16” 3 4 / ” Std. Extended 2 35/16” 3” 35/16” 3 4 / ” Extra Extended 2 413/16” 3” 35/16”

UNIVERSALLY INTERCHANGEABLE WELLS

Fig. 3

Basic Types Bulb Size Model Well Is of Number Used With Control Used F89-0007 230, 241, 2A38 71/4 x 3/8” and 63/4 x 3/8” F89-0027 1609, 1629, 2A23 53/4 x 3/8” F89-0033 11B06, 11B37, 1182 31/2 x 7/16” F89-0036 11B06, 11B37, 1182 31/2 x 7/16” F89-0148 All 215/16 x 7/16”

Well Description Pipe Size Figure Dimensions NPT Shank Number A B C 1 2 / ” Standard 3 15/8” 81/4” 89/16” / ” / ” 1 2 / ” 1 2 / ” 1 2 3 4

Standard Standard Standard Standard

3 15/8” 3 15/8” 3 15/8” 3 15/8”

6” 213/16” 213/16” 213/16”

65/16” 31/8” 31/8” 31/2”

UNIVERSALLY INTERCHANGEABLE WELLS

Fig. 4

Basic Types Bulb Size Model Well Is of Number Used With Control Used F89-0062 11B18, 11B05, — 11B55, 1131 F89-0063 11B18, 11B05, — 11B55, 1131 F89-0075 11B18, 11B05, — 11B55, 1131

www.white-rodgers.com

Well Description Pipe Size Figure Dimensions NPT Shank Number A B C 1 2 / ” Standard 4 15/8” 213/16” 31/8” / ” Standard 4 15/8” 1 2 / ” Standard 4 15/8” 3 4

213/16”

31/8”

213/16”

31/8”

147

HYDRONIC

Fig. 1

PARTS AND ACCESSORIES TEMPERATURE AND HOT WATER CONTROLS 1000–1100 SERIES

Item Number



Model Number

Description

F71-0924

Well adapter for 1100 series bulbs.

F85-0003



Wrench for tamper resistant screws found on temperature dials.

F145-0163 Heat transfer compound.

F145-0650 F71-0924 and F145-0163 packed together.

COMPACT ZONE VALVES 13A00 SERIES

Item Number

HYDRONIC

Item Number

Model Number

F19-0097 F19-0104

F19-0190

MOTOR 24v motor

F65-0439

BODY SEAL RING

F84-1215

VALVE DISC Contains one disc, spring, E-ring and body seal ring.

Description MOTOR ASSEMBLIES For 1311-102, -103, -104 For 1361-102, -103, -104 Water seal replacement kit not included.

VALVE ASSEMBLIES F84-0433 1311-102 and 1361-102 (3/4”) F84-0434 1311-103 and 1361-103 (1”) F84-0435 1311-104 and 1361-104 (11/4”)

WATER SEAL REPLACEMENT KIT (Quad ring. “O” ring, Tru-arc ring and cotter pin) F92-0227 1311-102 and 1361-102 (3/4”) F92-0228 1311-103 and 1361-103 (1”) F92-0229 1311-104 and 1361-104 (11/4”)

148

Description

POWER HEAD (includes seal ring) For 2-way zone valves F19-0181 25v with conduit hub F19-0187 25v with plug-in panel Includes auxiliary switch.

ZONE VALVES – 1300 SERIES

Model Number

www.white-rodgers.com