Following Equipment. following equipment. Transformers for low-voltage halogen lamps. Electronic step-down converters for low-voltage halogen lamps

183 Following Equipment Transformers for low-voltage halogen lamps Electronic step-down converters for low-voltage halogen lamps With the help of te...
Author: Hope Phelps
39 downloads 3 Views 2MB Size
183

Following Equipment Transformers for low-voltage halogen lamps Electronic step-down converters for low-voltage halogen lamps With the help of temperature and service-life tests conducted during the construction phase, Vossloh-Schwabe’s electronic converters are developed to provide a high degree of reliability in all areas of application. The quality and reliability of the electronic converters are documented during the production process by burn-in tests and by subjecting all components to continuous in-circuit and function tests. Vossloh-Schwabe (certified according to ISO 9001), conducts heat measurements and voltage tests using its own, state-of-the-art testing facilities and maintains its own, VIDE-approved EMC laboratory. The design of VS electronic converters enables amp brightness to be regulated using conventional phase-cutting trailingedge dimmers. Some types of converter can also be dimmed using phase-cutting leading-edge dimmers or can be equipped with a separate potentiometer connection for regulating lamp brightness. Depending on the ambient temperature and the degree of stress, the operating frequency of VS converters can range between 30 and 60 kHz. Electromagnetic safety transformers When using electromagnetic transformers, care must be taken to ensure the permissible output range is not exceeded as this could otherwise reduce the lamp’s service life or lead to the transformer generating excess heat. Furthermore, electromagnetic transformers must feature current overload protection either in the form of primary-side fine-wire fuse whose value is given on the type plate or a transformer with a thermal cutout. To this end, VS transformers with fuse holders form a particularly convenient option.

following equipment

All electromagnetic transformers made by VS are classed as safety transformers according to EN 61558 and guarantee a high reliability. The outstanding quality of VS products is documented by the Company’s ISO 9001 certification.

184

Independent Electronic Converters - LiteLine • Electronic safety converters for low-voltage halogen

• Dimming: optional with phase-cutting leading edge or

• Casing: heat-resistant polyamide • Mains frequency: 50-60 Hz • Protection against “no-load” operation • Protection against “short-circuit”: electric switch-off with

• Screw terminals: 2.5 mm • Quantity of screw terminals:

incandescent lamps 12 V

automatic restart

• Electronically controlled overload and temperature protection

• Suitable for installation in furniture and combustible surfaces

phase-cutting trailing edge dimmer (EST 35/12.650: only phase-cutting trailing-edge dimmer) 2

1x2-poles primary; 1x2-poles secondary

• Protection class II • SELV-equivalent • Degree of protection: IP20 • RFI-suppressed

• Power factor: 0.98 • Efficiency: 95% (EST 150/12.622: 94%)

A

following equipment

Electronic converter Type Ref. No. Shape: 28x37x128mm EST 35/12.650 186081 EST 70/12.380 186072 EST 105/12.381 186077 Shape: 33x37x184mm EST 150/12.622 186098

B

Voltage V prim./sec.

Nominal current A

Capacity range (W)

Ambient temperature ta (°C)

Casing temperature tc (°C)

Drawing

Weight g

230-240/11.4-11.8 230-240/11.3-11.7 230-240/11.3-11.7

0.152-0.158 0.30-0.31 0.43-0.44

5-35 20-70 20-105

-20 to 60 -20 to 45 -20 to 40

max. 70 max. 70 max. 85

A A A

80 85 95

230-240/11.2-11.6

0.595-0.605

50-150

-20 to 45

max. 85

B

175

185

Super-thin Electromagnetic Built-in Transformers Shape: 28x41 mm

• Electronic safety transformers for low-voltage incandescent lamps 12 V

• Vacuum-impregnated with polyester resin • Screw terminals: 0.5-2.5 mm • Protection class I • For these transformers without cutout, a slow-acting fuse 2

should be installed in the wiring on site

A

Safety transformers Type

Ref. No.

Capacity range (W) 50, 60 Hz V prim./sec.

Ambient temperature ta (°C)

Drawing

a mm

b mm

c mm

Primary fuse Weight kg AT

230 V / 50, 60 Hz STr 20/12.306 STr 50/12.342 STr 105/12.311

161781 507181 170002

15-20 35-50 60-105

60/B 40/B 30/F

A A B

155 175 240

140 165 230

63 83 160

0.55 0.73 1.33

230/11.5 230/11.5 230/11.5

0.125 0.250 0.500

following equipment

B

186

Following Equipment Electronic ballasts for compact and tubular fluorescent lamps Single-ended compact fluorescent lamps (tc lamps) Compact fluorescent lamps deserve the claim “particularly economical and eco-friendly” because they require considerably less energy in luminous comparison to incandescent lamps while guaranteeing a substantially longer service life. Tubular fluorescent lamps (t lamps) Despite the ongoing development of new lamp types outsides the family of fluorescent lamps, the majority of artificial light produced nowadays still comes from fluorescent lamps. As T lamps are characterized by both high light output and a long service life they are predominantly used for industrial purposes and in offices. Electronic Ballasts The brightness of fluorescent lamps can be regulated with the help of dimmable electronic ballasts. Adjusting lamp wattage leads to a further reduction of energy consumption and of the associated costs. The corresponding ELXd units from VS enable conventional 1–10 V control units to be connected via a bipolar 1-10V dimmer interface. Interfaces were developed in accordance with EN 60929. Under the consideration of the maximum current of the respective control unit, it is also possible to operate several electronic ballasts in parallel.

following equipment

VS electronic ballasts are developed to ensure a high degree of reliability in all areas of application.

187

Compact Electronic Built-in Ballasts ELXc - Warm start for compact fluorescent lamps

• Casing: heat-resistant polyamide • Power factor: 0.98 • Ambient temperature t : -20 to 50 °C • Casing temperature t : max. 65 °C • DC Voltage operation:

• Constant power consumption • For luminaries of protection class I • Degree of protection: IP20 • Fixing brackets for screws M4 • For lateral or base mounting • For lighting systems with high switching frequency

a

c

176-254V - for operation 198-254V - for ignition

(>5/day)

• Push-in terminals with push-button: 0.5-1.5 mm • RFI-suppresed

2

Lamp Output W

K2 with cord grip

Type

Base

Electronic built-in ballasts 13 TC-DEL G24q-1 TC-TEL GX24q-1 2 x 13 TC-DEL G24q-1 TC-TEL GX24q-1 18 TC-DEL G24q-2 TC-TEL GX24q-2 2 x 18 TC-DEL G24q-2 TC-TEL GX24q-2 26 TC-DEL G24q-3 TC-TEL GX24q-3 2 x 26 TC-DEL G24q-3 TC-TEL GX24q-3 *Circuit diagrams - See page 192

Power consumption W

Electronic ballast Type Ref. No.

Voltage AC 50, 60Hz, V ± 10 %

EEI *

a b c d Casing mm mm mm mm

System Output W Luminous factor %

1 x 12.5

ELXc 213.828

188355

220-240

A2 1

31

67

83.5 103 K2

15.0

100

2 x 12.5

ELXc 213.828

188355

220-240

A2 2

31

67

83.5 103 K2

28.0

100

1 x 16.5

ELXc 218.829

188354

220-240

A2 1

31

67

83.5 103 K2

21.0

100

2 x 16.5

ELXc 218.829

188354

220-240

A2 2

31

67

83.5 103 K2

38

100

1 x 24

ELXc 226.830

188292

220-240

A2 1

31

67

83.5 103 K2

27

100

2 x 24

ELXc 226.830

188292

220-240

A2 2

31

67

83.5 103 K2

53

100

following equipment

K2

188

Dimmable Compact Electronic Built-in Ballasts ELXd - Dimmable 1-10 V for TC-DEL, TC-TEL lamps

• Ignition time: < 2 sec. • Push-in terminals with push-button: 0.5-1.5 mm • RFI-suppresed • Constant power consumption • For luminaries of protection class I • Degree of protection: IP20 • Fixing brackets for screws M4 • For lateral or base mounting • For lighting systems with high switching frequency

• Casing: heat-resistant polyamide (K3) or heat-resistant polycarbonate (K4)

2

• Dimm range: approx. 3-100% of lamp power • Control voltage: DC 1-10 V acc. to EN 60929 with earth

leakage current 0.5 mA (protected if connected to mains voltage)

• For use with open- or closed-loop control units • Power factor: 0.98 at 100% operation • Ambient temperature t : 5 to 55 °C • Casing temperature t : max. 70 °C • DC Voltage operation: 198-254 V a

(>5/day)

c

K3

K4

following equipment

Lamp Output W 2 x 18 2 x 26 2 x 32 2 x 42

K4 with venting slits

Electronic ballast Type

Base

TC-DEL TC-TEL TC-DEL TC-TEL TC-TEL TC-TEL

G24q-2 GX24q-2 G24q-3 GX24q-3 GX24q-3 GX24q-4

*Circuit diagrams - See page 192

System

Power consumption W 2 x 16.5

Type

Ref. No. 179796

Voltage AC EEI * 50, 60Hz, V ± 10 % 220-240 A1 3

a b c d Casing mm mm mm mm 38 102 134 158 К4

Output W Luminous factor % 37.0 100

ELXd 218.803

2 x 24

ELXd 242.807

188100

220-240

A1 3

38

102 134 158 K4

53

100

2 x 32 2 x 42

ELXd 242.807 ELXd 242.807

188100 188100

220-240 220-240

A1 3 A1 3

38 38

102 134 158 K4 102 134 158 K4

71 62

100 100

189

Ballasts for Use in Non-EU Markets 18-58W, 230 V For compact fluorescent lamps; Shape: 28x41 mm

• Vacuum-impregnated with polyester resin • Push-in terminal for leads: 0.5 - 1 mm • For the automatic luminaire wiring: • IDC terminals for leads H05V-U 0.5 2

tw 130

Lamp Output W

Type

230 V, 50 Hz 18 TC-D/TC-T 26 TC-D/TC-T

Base

Current mA

G24d-2/GX24d-2 G24d-3/GX24d-3

220 325

Ballast Type

Ref. No.

V, Hz

a b c Weight mm mm mm kg

Δt / Δtan K

Capacitor Cp μF

Current mA

LN 181.850 LN 26.813

503871 509502

230, 50 230, 50

85 75 27 110 100 45

65/165 55/145

2.0 3.5

110 140

0.28 0.45

following equipment

• Protection class I • Without CE mark • BOX - output: 2x18 W, base: G24d-2/GX24d-2 available • BOX - output: 2x26 W, base: G24d-3/GX24d-3 available

190

Following Equipment Ballasts for high-pressure sodium lamps (HS), Metal Halide Lamps (HI) and Mercury Vapour Lamps (HM) Electronic Ballasts The critical behavior of high-pressure lamps during the starting and hot restart phases just as their sensitivity against main voltage fluctuations both influence light color and lamp service life. However, operating high-pressure lamps with electronic ballasts not only avoids these problems but increases lamp efficiency in comparison with magnetic ballasts. The electronic ballast evaluates lamp data during operation and adjusts the lamp current to suit. This guarantees operation in all operation phases. An electronic ballast will ensure a lamp safety turned off at the end of its service life, thereby preventing any risk in the event of the rare rectifying effect occurring with high-pressure lamps (HI and C-HI) featuring an outer bulb. With the help of temperature and service-life tests, VS electronic ballasts guarantee a high degree of reliability.

following equipment

Magnetic Ballasts The electrical specifications of VS’s range of ballasts comply with lamp-specific requirements. VS attaches great importance to ensuring the impedance value of electro-magnetic ballasts is kept with within particularly narrow tolerances. This advantage, which is achieved by individual adjustment of the air gap during the automated production and testing process of every ballast, decisively contributes to optimizing the light output, light color and service life of discharge lamps.

191

Control Gear Units for HS and HI Lamps 35 to 150W Compact plastic casing; Shape: 61 x 72 mm

• For high pressure sodium lamps (HS) and metal halide lamps (HI) and ceramic discharge lamps (C-HI)

• Ballast, timer ignitor, compensation capacitor and thermal

cutout with automatic reset as a compact control gear unit

• As individual components no longer need to be wired,

there is a significant reduction in assembly time and costs

• Protection class II • Degree of protection: IP40 • Permissible load capacity: 20-1000 pF • tw 130 • Push-in terminals: 0.75-1.5 mm • Cord grips for mains and lamp leads • Distance to the lamp: max. 10 m

Lamp Output W

Control Gear unit Type

230 V / 50 Hz 70 HS, HI 150 HS, HI

Current A

Type

Ref. No.

Voltage AC V, Hz

Mains current A

Power factor λ

ta °C

a b Weight mm mm kg

0.98 1.80

VNaHJ 70PZT.051 VNaHJ 150PZT.052

509496 509497

230, 50 230, 50

0.370 0.740

0.97 0.94

40 45

222 217 1.53 249 245 2.24

following equipment

2

192

Symbol definitions and glossary Lamps/Sockets RX7s E40 E27 PAR20/E27, PAR30/E27 Е27 (energy saving) Е14 (energy saving) PLC G12 G4

Colors WH

GR

BK

GD

GM

SG

CH

SN

MG

White Grey Black Gold

Glossary LxWxH  EEI

Circuit diagrams for fluorescent lamps 1

GU4/GU 5.3 CDM-R Fluorescent lamp Double-end General Characteristics

Symbol definition

30

AC

AB

PE

1 2 3 4 5 6

Silver Grey Chrome

2

Satin Nickel

1 2 3 4 5 6

Metal Gun Anti Copper Anti Brass Brushed

Glass Colors Transparent Orange Red

Insulation class I

Purple

Insulation class III

Blue

IP

Green

Built-in wall Built-in Built-in ceiling

ElXc PE

F

Deflection angle

ElXc

Gold Matt

3

AR111

Size (long x wide x height) Diameter Energy Efficiency Index

ElXc PE DC 1 2 3 4 5 6 7