FLUE SYSTEMS. Flueing options and accessories. Multiple flue options for Standard and Condensing Boilers GAS BOILERS

GAS BOILERS FLUE SYSTEMS Flueing options and accessories Multiple flue options for Standard and Condensing Boilers w w w. c h a f f o t e a u x . c...
Author: Douglas Oliver
0 downloads 0 Views 2MB Size
GAS BOILERS

FLUE SYSTEMS

Flueing options and accessories Multiple flue options for Standard and Condensing Boilers

w w w. c h a f f o t e a u x . c o . u k

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Technical Guide The best combination of comfort and economy

Chaffoteaux & Maury wall-hung gas appliances offer great flexibility in flueing arrangements, to accommodate all installation requirements. This technical guide will help you to select the correct flue and components, for the location of the boiler within a property.

1 - Standard Horizontal The standard flue can rotate through a full 360˚ allowing the greatest flexibility in siting. 2 - Raised Horizontal Using a vertical adaptor together with standard flue extensions it is possible to extend the overall length of a standard flue and still terminate horizontally.

3 1

4

3 - Vertical For situations where it is necessary to terminate the flue vertically through a tiled or flat roof.

2

4 - Twin Pipe (Biflux) Suitable for applications where the appliance is either sited further from a suitable external wall or where building obstructions do not allow conventional horizontal or vertical flueing arrangements.

2 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Flue Terminal Positions In accordance with BS 5440-1:2000

DE H

H

F

I

P L

JK A

P

E

B C

M N I

Installation Conditions Terminal Position A Directly below an opening, air brick, opening windows, etc B Above an opening, air brick, opening windows, etc C Horizontally to an opening, air brick, opening windows, etc D Below gutters, soil pipes or drain pipes E Below eaves F Below balconies or car port roof G From vertical drain or soil pipe H From an internal or external corner I Above ground roof or balcony level J From a surface facing the terminal K From a terminal facing the terminal L From an opening in the car port (e.g. door, window) into the dwelling M Vertically from a terminal on the same wall N Horizontally from a terminal in the same wall P Fixed by use of terminal and matched flashing plate

mm 300 300 300 75 200 200 150 300 300 600 1200 1200 1500 300 -

C&M - Flueing options and accessories - 3

Supplied By www.heating spares.co Tel. 0161 620 6677

Flue Types Standard horizontal C&M wall-hung appliances can be fitted up to 4 metres from an outside wall using the standard horizontal flue kit. Full 360˚ rotation of the flue allows the greatest flexibility. The optional 45˚ and 90˚ bends make the system ideal for boiler changes.

Horizontal incorporating 2 x 45˚ bends

With a special rubber sealing ring the flue can be installed and sealed externally at high levels without requiring access to the outside. Unobtrusive terminal. The standard kit contains all that is necessary for a basic installation. Full range of accessories available.

Horizontal incorporating 45˚ or 90˚ bend

Raised horizontal C&M wall-hung appliances can be fitted up to 15 metres from an outside wall using 80/125mm flue components (4 metres using 60/100mm flue components). As long as the flue terminates horizontally, the main length of the flue can be vertical. Uses standard straight flue extensions and bends. With a special rubber sealing ring the flue can be installed and sealed externally at high levels without requiring access to the outside (60/100mm only).

Raised Horizontal, side exit

Unobtrusive terminal. Simply add bends and straight extensions as required to complete the installation (60/100mm only). For 80/125mm use the 80/125 vertical adaptor. Full range of accessories available. Raised Horizontal incorporating 2 x 90˚ bend and straight extensions

4 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Vertical Flue can terminate vertically up to 16 metres away from the boiler using the 80/125mm Vertical Flue Kit (5 metres using the 60/100mm Vertical Flue Kit).

Vertical Flue incorporating 2 x 90˚ bends

Removes the need to fit the boiler near an outside wall. A multitude of accessories make a very adaptable and flexible flue system. Vertical terminals for flat, sloping, tiled or slated roofs available. Terminals and Flashings available in terracotta finish to special order. Vertical Flue incorporating 1 x 90˚ bend and 2 x 45˚ bends

Twin Pipe (Biflux)

The ultimate in flexibility. C&M wall-hung boilers can be fitted with up to 30 metres of Biflux flue.

Twin Pipe Flue with single vertical terminal

Can terminate on flat, sloping, slated or tiled roofs. Vertical, horizontal and even separate terminals are available. Full range of accessories available.

C&M - Flueing options and accessories - 5

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

List of Contents System Configurations

Standard Efficiency Coaxial 60/100 - Standard/Raised Horizontal

page 10

Coaxial 60/100 - Vertical

page 11

Coaxial 80/125 - Raised Horizontal

page 13

Coaxial 80/125 - Vertical

page 15

Twin Pipe 80 - Horizontal

page 17

Twin Pipe 80 - Vertical

page 18

High Efficiency Condensing Coaxial 60/100 - Standard/Raised Horizontal

page 21

Coaxial 60/100 - Vertical

page 22

Coaxial 80/125 - Raised Horizontal

page 24

Coaxial 80/125 - Vertical

page 25

Twin Pipe 80 - Horizontal

page 27

Twin Pipe 80 - Vertical

page 29

6 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency Which flue options do you need? MX2 24 FF & 30 FF

Lengths quoted are maximum straight length equivalents (including bends) (see table for full SLE lengths details). Figures marked with * relate to the 30 FF model.

C&M - Flueing options and accessories - 7

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency Which flue options do you need? Britony Combi SE, Britony System II, Britony System II Plus & Calydra Comfort

Lengths quoted are maximum straight length equivalents (including bends) (see table for full SLE lengths details). Figures marked with * relate to 100 models.

8 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency Condensing Which flue options do you need? Calydra Green & Centora Green

Lengths quoted are maximum straight length equivalents (including bends) (see table for full SLE lengths details).

C&M - Flueing options and accessories - 9

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (horizontal)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

TELESCOPIC HORIZONTAL COAXIAL KIT 600mm coaxial kit complete with 90° elbow and terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

707067

0.75m

STANDARD HORIZONTAL COAXIAL KIT 1000mm coaxial kit complete with 90° elbow and terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

705958

1.0m

STANDARD HORIZONTAL COAXIAL KIT WITHOUT ELBOW 750mm coaxial kit complete with terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

705783

0.75m

90° COAXIAL ELBOW 90° coaxial elbow Packet with gaskets and fixing screws

1

705787

0.8m

10 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (horizontal) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

45° COAXIAL ELBOW 45° coaxial elbow Packet with gaskets and fixing screws

2

705788

0.5m

COAXIAL EXTENSION 1000mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

705786

1.0m

COAXIAL EXTENSION 500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

705790

0.5m

COAXIAL EXTENSION 160mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

705812

0.2m

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

C&M - Flueing options and accessories - 11

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (vertical) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

45° COAXIAL ELBOW 45° coaxial elbow Packet with gaskets and fixing screws

2

705788

0.5m

COAXIAL EXTENSION 1000mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

705786

1.0m

COAXIAL EXTENSION 500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

705790

0.5m

COAXIAL EXTENSION 250mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

705812

0.2m

COAXIAL STUB WITH CONDENSATE TRAP 160mm coaxial stub with condensate discharge connection Packet with gaskets and fixing screws

1

705792

0.3m

STANDARD VERTICAL FLUE (BLACK) Vertical flue kit 80/125 complete with 60/100 conical adaptor Packet with gaskets and fixing screws

1

705764

1.0m

STANDARD VERTICAL FLUE (TERRACOTTA)

1

705765

LEAD FLASHING BASE CAP (BLACK) Lead pitched roof flashing with collar

1

705781

LEAD FLASHING BASE CAP (TERRACOTTA)

1

705724

12 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (vertical) SCHEME

DESCRIPTION OF COMPONENTS VENT BASE CAP FOR FLAT ROOF (BLACK)

QTY

CODE

1

704830

Air/exhaust systems with coaxial tubes Ø 80/125 (raised

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

ADAPTOR 60/100 - 80/125 Conical adaptor to use 80/125 coaxial flue system Packet with gaskets and fixing screws

1

706014

HORIZONTAL TERMINAL 600mm coaxial kit complete with 90° elbow and terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

61020448

SLE

horizontal)

SLE

0.6m

C&M - Flueing options and accessories - 13

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (raised SCHEME

DESCRIPTION OF COMPONENTS

horizontal)

QTY

CODE

SLE

90° COAXIAL ELBOW 90° coaxial elbow Packet with gaskets and fixing screws

1

61304857

2.0m

45° COAXIAL ELBOW 45° coaxial elbow Packet with gaskets and fixing screws

1

61304854

1.0m

COAXIAL EXTENSION 2000mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61304856

2.0m

COAXIAL EXTENSION 1000mm coaxial extension with centering spring Packet with gaskets and fixing screw

1

61304853

1.0m

COAXIAL EXTENSION 500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61304852

0.5m

COAXIAL EXTENSION 250mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61304851

0.3m

14 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

ADAPTOR 60/100 - 80/125 Conical adaptor to use 80/125 coaxial flue system Packet with gaskets and fixing screws

1

706014

45° COAXIAL ELBOW 45° coaxial elbow Packet with gaskets and fixing screws

1

61304854

1.0m

COAXIAL EXTENSION 2000mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61304856

2.0m

COAXIAL EXTENSION 1000mm coaxial extension with centering spring Packet with gaskets and fixing screw

1

61304853

1.0m

C&M - Flueing options and accessories - 15

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

61304852

0.5m

COAXIAL EXTENSION 500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

COAXIAL EXTENSION 250mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61304851

0.2m

COAXIAL EXTENSION (TELESCOPIC) 50-300mm telescopic coaxial extension with centering spring Packet with gaskets and fixing screws

1

61304855

0.3m

VERTICAL TERMINAL (BLACK) (80/125) Vertical flue kit 80/125

1

61304849

1.0m

VERTICAL TERMINAL (TERRACOTTA) (80/125)

1

61304850

1.0m

CONDENSATE TRAP Condense trap with drain point (for use with flues over 5 metres)

1

61010904

0.9m

LEAD FLASHING BASE CAP (BLACK) (5/25O) Lead pitched roof flashing with collar LEAD FLASHING BASE CAP (BLACK) (25/45O) LEAD FLASHING BASE CAP (BLACK) (35/55O) LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O) LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O) LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)

1

61017921

1 1 1 1 1

61017922 61017923 61008460 61008461 61008462

VENT BASE CAP FOR FLAT ROOF (BLACK)

1

60077757

10110

16 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (horizontal)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

TWIN PIPE FLUE KIT Adaptor 60/80 d 100 for connection to boiler Packet with gaskets and fixing screws N° 2 90° elbows N° 2 pipes L1000 MF Air intake terminal

1

706026

90° MF ELBOW (Ø80) 90° elbow in aluminium (white)

2

705758

90° MF ELBOW (Ø80)

20

705759

45° MF ELBOW (Ø80) 45° elbow in aluminium (white)

2

705760

1.0 m

PIPE - 2000 mm (Ø80) Pipe L2000 MF in aluminium (white)

1

706279

2.0 m

1.3 m

C&M - Flueing options and accessories - 17

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (horizontal) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

PIPE - 1000 mm (Ø80) Pipe L1000 MF in aluminium (white)

1

705761

1.0 m

PIPE - 1000 mm (Ø80)

10

705762

PIPE - 500 mm (Ø80) Pipe L500 MF in aluminium (white)

1

705770

INTAKE VENT CAP Air intake Ø80 (plasticl) Fixing screws

1

704738

STAINLESS STEEL EXHAUST VENT CAP Exhaust terminal Ø80 (stainless steel) Fixing screws

1

705113

Air/exhaust systems with separate tubes Ø 80 (vertical)

18 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

0.5m

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (vertical)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

Adaptor (Ø60/80) FOR TWIN PIPE SYSTEM Adaptor Ø60/80 with Ø100 connection to boiler Packet with gaskets and fixing screws

1

705757

STUB (Ø80) WITH CONDENSATE COLLECTOR Pipe L85 MF in aluminium (white) with condensate drain

1

705798

LEAD FLASHING BASE CAP (BLACK) Lead pitched roof flashing with collar

1

705781

SLE

0.2m

705724

LEAD FLASHING BASE CAP (TERRACOTTA) VENT BASE CAP FOR FLAT ROOF (BLACK)

1

704830

VENT CAP (Ø80) FOR VERTICAL TERMINATION Terminal Ø80 for flat roofs (black) Fixing screws

1

705160

PIPE REDUCER (Ø118/80) Adaptor for vertical terminal

1

707166

STANDARD VERTICAL FLUE (BLACK) Vertical flue kit 80/125 complete with 60/100 conical adaptor Packet with gaskets and fixing screws

1

705764

STANDARD VERTICAL FLUE (RED)

1

705765

C&M - Flueing options and accessories - 19

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

Standard Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (special componnets)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

WALL BRACKET KIT Wall fixing bracket Ø80-120 Complete with plugs

3

705778

PIPE BRIDGE (Ø80) Pipe bridge with Ø80/80 M/M inlet and Ø100 M outlet

1

705767

COVER PLATE (Ø80) EPDM cover plate

2

705784

ADAPTOR (Ø80) FOR INSULATED PIPES Adaptor Ø80 for connection insulated exhaust pipes complete with fixing screws

1

705769

0.2m

INSULATED PIPE L 1000 Pipe Ø80/100 L 1000 insulated Packet with gaskets and fixing screws

1

705771

1m

90° INSULATED ELBOW (Ø80) 90° insulated elbow Ø80/100 Packet with gaskets and fixing screws

1

705772

1.3m

45° INSULATED ELBOW (Ø80) 45° insulated elbow Ø80/100 Packet with gaskets and fixing screw

1

705773

1m

20 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

SLE

10m

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (horizontal)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

STANDARD HORIZONTAL COAXIAL KIT 1000mm coaxial kit AL/PP complete with 90° elbow and terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

61309947

1.0 m

STANDARD HORIZONTAL COAXIAL KIT WITHOUT ELBOW 600mm coaxial kit AL/PP complete with terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

61310156

0.75 m

90° COAXIAL ELBOW 90° coaxial elbow AL/PP Packet with gaskets and fixing screws

1

61309942

0.8 m

45° COAXIAL ELBOW 45° coaxial elbow AL/PP Packet with gaskets and fixing screws

2

61309943

0.5 m

C&M - Flueing options and accessories - 21

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

COAXIAL EXTENSION 1000 mm Coaxial extension 1000mm (Ø60/100) with centering spring

1

61309946

1.0 m

COAXIAL EXTENSION 500 mm Coaxial extension 500mm (Ø60/100) with centering spring

1

61309945

0.5m

COAXIAL EXTENSION 250 mm Coaxial extension 250mm (Ø60/100) with centering spring

1

61309944

0.2m

WALL BRACKET KIT Wall fixing bracket Ø80-120 Complete with plugs

3

705778

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

22 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

STANDARD VERTICAL FLUE (BLACK) Vertical flue kit 80/125 complete with 60/100 conical adaptor Packet with gaskets and fixing screws

1

61310342

1.0m

STANDARD VERTICAL FLUE (TERRACOTTA)

1

61310343

1.0m

LEAD FLASHING BASE CAP (BLACK) (5/25O) Lead pitched roof flashing with collar LEAD FLASHING BASE CAP (BLACK) (25/45O) LEAD FLASHING BASE CAP (BLACK) (35/55O) LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O) LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O) LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)

1

61017921

1 1 1 1 1

61017922 61017923 61008460 61008461 61008462

VENT CAP FOR FLAT ROOF (BLACK)

1

60077757

COAXIAL EXTENSION 1000 mm Coaxial extension 1000mm (Ø60 M/F) AL/PP with centering spring

1

61309946

1.0m

COAXIAL EXTENSION 500 mm Coaxial extension 500mm (Ø60/100 M/F) AL/PP with centering spring

1

61309945

0.5m

COAXIAL EXTENSION 250 mm Coaxial extension 250mm (Ø60/100 M/F) AL/PP with centering spring

1

61309944

0.2m

C&M - Flueing options and accessories - 23

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (raised

SCHEME

DESCRIPTION OF COMPONENTS

horizontal)

QTY

CODE

ADAPTOR 60/100 - 80/125 Conical adaptor to use 80/125 coaxial flue system Packet with gaskets and fixing screws

1

61309663

HORIZONTAL TERMINAL 600mm coaxial kit complete with 90° elbow and terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

61309494

0.75m

90° COAXIAL ELBOW 90° coaxial elbow Packet with gaskets and fixing screws

1

61309165

2.0m

45° COAXIAL ELBOW 45° coaxial elbow Packet with gaskets and fixing screws

1

61309164

1.0m

24 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

SLE

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (raised SCHEME

DESCRIPTION OF COMPONENTS

horizontal)

QTY

CODE

SLE

COAXIAL EXTENSION 1500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309167

1.5m

COAXIAL EXTENSION 1000mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309166

1.0m

COAXIAL EXTENSION 500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309169

0.5m

COAXIAL EXTENSION 250mm oaxial extension with centering spring Packet with gaskets and fixing screws

1

61309168

0.2m

Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

C&M - Flueing options and accessories - 25

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (vertical) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

ADAPTOR 60/100 - 80/125 Conical adaptor to use 80/125 coaxial flue system Packet with gaskets and fixing screws

1

61309663

45° COAXIAL ELBOW 45° coaxial elbow Packet with gaskets and fixing screws

1

61309164

1.0m

COAXIAL EXTENSION 1500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309167

1.5m

COAXIAL EXTENSION 1000mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309166

1.0m

COAXIAL EXTENSION 500mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309169

0.5m

COAXIAL EXTENSION 250mm coaxial extension with centering spring Packet with gaskets and fixing screws

1

61309168

0.2m

VERTICAL TERMINAL (BLACK) 600mm coaxial kit complete with 90° elbow and terminal Packet with gaskets and fixing screws Cover plate in EPDM

1

61309163

1.0m

VERTICAL TERMINAL (TERRACOTTA))

1

61310344

26 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

SLE

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Coaxial Air/exhaust systems with coaxial tubes Ø 80/125 (vertical) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

LEAD FLASHING BASE CAP (BLACK) (5/25O) Lead pitched roof flashing with collar LEAD FLASHING BASE CAP (BLACK) (25/45O) LEAD FLASHING BASE CAP (BLACK) (35/55O) LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O) LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O) LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)

1

61017921

1 1 1 1 1

61017922 61017923 61008460 61008461 61008462

VENT BASE CAP FOR FLAT ROOF (BLACK)

1

60077757

SLE

Air/exhaust systems with separate tubes Ø 80 (horizontal)

C&M - Flueing options and accessories - 27

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (horizontal) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

1

61309715

2

61310174

1.3m

1

61310173

1.0m

1

61310170

1.5m

PIPE - 1000 mm (Ø80) Pipe L1000 MF in aluminium (white)

1

61310169

1.0m

PIPE - 500 mm (Ø80) Pipe L500 MF in aluminium (white)

1

61310171

0.5m

PIPE - 250 mm (Ø80) Pipe L250 MF in aluminium (white)

1

61310172

0.2m

Adaptor (Ø60/80) FOR TWIN PIPE SYSTEM Adaptor Ø60/80 with Ø100 connection to boiler Packet with gaskets and fixing screws

SLE

90° MF ELBOW (Ø80) 90° elbow in aluminium (white)

45° MF ELBOW (Ø80) 45° elbow in aluminium (white)

PIPE - 1500 mm (Ø80) Pipe L1500 MF in aluminium (white)

28 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (horizontal) SCHEME

DESCRIPTION OF COMPONENTS HORIZONTAL TERMINALS Exhaust/intake terminals (stainless steel) 1000mm Ø80 pipe exhuast 1000mm Ø80 pipe intake EPDM cover plate

QTY

CODE

SLE

1

61310345

2.0m

Air/exhaust systems with separate tubes Ø 80 (vertical)

C&M - Flueing options and accessories - 29

Supplied By www.heating spares.co Tel. 0161 620 6677

GAS BOILERS www.chaffoteaux.co.uk

High Efficiency - Twin Pipe Air/exhaust systems with separate tubes Ø 80 (vertical) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

SLE

PIPE BRIDGE (Ø80) Pipe bridge with Ø80/80 M/M inlet and Ø100 M outlet

1

61309715

10m

45° MF ELBOW (Ø80) 45° elbow in aluminium (white)

2

61310173

1.0m

PIPE - 1000 mm (Ø80) Pipe L1000 MF in aluminium (white)

1

61310169

STANDARD VERTICAL FLUE (BLACK) Vertical flue kit 80/125 complete with 60/100 conical adaptor Packet with gaskets and fixing screws

1

1.0m

61310168

Air/exhaust systems with separate tubes Ø 80 (special components) SCHEME

DESCRIPTION OF COMPONENTS

QTY

CODE

COVER PLATE (Ø80) EPDM cover plate

1

705784

WALL BRACKET KIT Wall fixing bracket Ø80-120 Complete with plugs

1

705778

30 - C&M - Flueing options and accessories

Supplied By www.heating spares.co Tel. 0161 620 6677

SLE

GAS BOILERS www.chaffoteaux.co.uk

Notes

C&M - Flueing options and accessories - 31

Supplied By www.heating spares.co Tel. 0161 620 6677

MTS (GB) Limited

MTS Building, Hughenden Avenue, High Wycombe, Bucks HP13 5FT Tel: 01494 755600 Fax: 01494 459775 Technical Suppor t Help Line: 01494 539579

w w w. c h a f f o t e a u x . c o . u k

Supplied By www.heating spares.co Tel. 0161 620 6677

In the interests of our customers, MTS (GB) Limited is continually developing these products to improve both performance and design. We therefore reserve the right to change specification without prior notice. This brochure is accurate at the date of printing. Consumer statutory rights are not affected.

Month & Year Printed by Vario Press