INDUSTRIAL COOLERS
DESCRIPTION OF HEAT TRANSFER SURFACE VPL • Material of exchanger: Cu/Al, Cu/Cu • Diameters of pipes: 8, 10, 12 and 16 mm • Fin spacing: 1.58, 1.81, 2.12, 2.31, 2.83, 3.18, 3.63, 4.23 mm • Fin thickness: 0.10, 0.14, 0.20 mm (Al, Cu) • Fins connected to the pipes by expansion Application: air coolers parts, exchangers OVF and CVF, transformer oil coolers, …
Wettag • Material of exchanger: Cu/Cu, Cu/Fe, Fe/Fe, Ms/Fe or Ms/Ms • Diameters of pipes: 16 mm • Fin spacing: 1.5, 2.1, 2.5, 3.5, 6 mm • Fin thickness: 0.16, 0.25 mm (Cu), 0.3 mm (Fe), 0.25 mm (Ms) • Fins connected to the pipes by zinc or tin Application: steam air heater OPD, cooling coils, coolers PDH, hydrogen coolers, parts of coolers, …
Fins Coils with Flat-oval Pipes • Material of exchanger: Ms/Fe, Ms/Ms • Diameters of pipes: 2.5 x 16mm • Fin spacing: 2.7 mm • Fin thickness: 0.16 mm (Ms), 0.15 mm (Fe) • Fins connected to the pipes by tin Application: cooling radiators for locomotives and stationary engines
Water Fins Coils • Material of exchanger: Fe/Al • Diameters of pipes: 16mm • Fin spacing: 2 mm • Fin thickness: 0.2 mm (Al) • Fins connected to the pipes by interference fit Application: steam air heater OPC
JANKA belongs to the traditional producers of the air-handling units, ventilators, industrial coolers and heat exchangers. The company with its production halls are based in the outskirts of Prague. Thanks to our regional offices and distributors we are present in the Czech republic as well as in other European countries. Division of the Industrial Coolers JANKA ENGINEERING s.r.o. is one of the leading producers of industrial coolers specialized on various types of heat exchangers. These products are used as parts of a variety of machines employed in the industry, energy industry, railway and shipping transportation (e.g. coolers in locomotives, diesel engines, transformers and turbo generators). The exchangers are generally designed for the indoors. However selected products comply with outdoors conditions, explosion prove and also with applications with required seismic resistance. To our business partners such companies as ŠKODA PLZEŇ, ČKD, ALSTOM POWER PBS, ZOS ZVOLEN, SIEMENS, BRUSH SEM belong.
PRODUCT CATEGORIZATION Cooling coils for industrial assembly
Transformer oil coolers Hydrogen coolers Cooling array Coolers PDH Circular air coolers Cooling units
Cooling and heating coils for air-handling units
Water
Steam heater
Heater
OVC
Cooler
CVF
Low pressure High pressure
OPC OPD
Transformer Oil Coolers General Data
Heat transfer surface VPL Cu/Al or Cu/Cu, Wettag Cu/Ms, Cu/Cu or Ms/Ms Supplied assembled Forced air flow ensured by two axial fans 6 standardized capacity versions
Working Medium Main Operation Field Oil cooled by air Forced oil flow required
Cooling of transformer oil by the atmospheric air
Hydrogen Coolers General Data
Heat transfer surface Wettag Cu/Ms, Cu/Cu or Ms/Ms Customized dimensions and capacity
Working Medium Main Operation Field Hydrogen cooled by water Forced water flow required
Cooling of generators and other dynamo electric machinery
Cooling Arrays General Data
Heat transfer surface Wettag Cu/Ms, Cu/Cu or Ms/Ms Customized dimensions and capacity
Working Medium Main Operation Field Compressed air cooled by waterForced water flow required
Cooling of turbocompressors
Coolers PDH General Data
Heat transfer surface Wettag Cu/Ms, Cu/Cu or Ms/Ms Dimensions and capacity given by the size of turbo-charger
Working Medium Main Operation Field Water Sea water Forced water flow required
Cooling of diesel turbo-charged engines
Circular Air Coolers
• Directly on the motorr • Inside of the frame of the motor • Below the motor
General Data
Heat transfer surface VPL Cu/Al, Cu/Cu, Wettag Ms/Fe, Cu/Fe or Cu/Cu Customized dimensions and capacity
Working Medium Main Operation Field Air cooled by water Forced flow of water required
Cooling of generators and turbogenerators Cooling of electromotors
Cooling Units with Flat-oval Tubes General Data
Heat transfer surface Wettag Ms/Fe or Ms/Ms 15 standardized versions
Working Medium Main Operation Field Water cooled by air Forced flow of water required
Cooling of combustion engines Cooling of water circuits in locomotives and stationary engines
Coils for Installation in Ventilation Ducts Water Heaters OVF, Coolers CVF General Data
Heat transfer surface VPL Cu/Al or Cu/Cu 39 sizes ,1-4 rows of heaters and 3-8 rows of coolers
Working Medium Main Operation Field Air cooled or heated by water Forced flow of water required
Air-handling units Air ducts
Steam Heaters OPC and OPD General Data
Heat transfer surface Wettag Fe/Fe, Fe/Al or Water Fin Coils Fe/Al 24 dimension versions, 6 rows
Working Medium Main Operation Field Air heated by steam Forced flow of water required
Air-handling units Air ducts
JANKA ENGINEERING s.r.o. Vrážská 143, 153 00 Praha 5 – Radotín Czech Republic E-mail:
[email protected] Tel.: (+420) 251 088 777 Fax: (+420) 251 088 840
Your local sales office:
www.JANKA.cz