INDUSTRIAL COOLERS

DESCRIPTION OF HEAT TRANSFER SURFACE VPL • Material of exchanger: Cu/Al, Cu/Cu • Diameters of pipes: 8, 10, 12 and 16 mm • Fin spacing: 1.58, 1.81, 2.12, 2.31, 2.83, 3.18, 3.63, 4.23 mm • Fin thickness: 0.10, 0.14, 0.20 mm (Al, Cu) • Fins connected to the pipes by expansion Application: air coolers parts, exchangers OVF and CVF, transformer oil coolers, …

Wettag • Material of exchanger: Cu/Cu, Cu/Fe, Fe/Fe, Ms/Fe or Ms/Ms • Diameters of pipes: 16 mm • Fin spacing: 1.5, 2.1, 2.5, 3.5, 6 mm • Fin thickness: 0.16, 0.25 mm (Cu), 0.3 mm (Fe), 0.25 mm (Ms) • Fins connected to the pipes by zinc or tin Application: steam air heater OPD, cooling coils, coolers PDH, hydrogen coolers, parts of coolers, …

Fins Coils with Flat-oval Pipes • Material of exchanger: Ms/Fe, Ms/Ms • Diameters of pipes: 2.5 x 16mm • Fin spacing: 2.7 mm • Fin thickness: 0.16 mm (Ms), 0.15 mm (Fe) • Fins connected to the pipes by tin Application: cooling radiators for locomotives and stationary engines

Water Fins Coils • Material of exchanger: Fe/Al • Diameters of pipes: 16mm • Fin spacing: 2 mm • Fin thickness: 0.2 mm (Al) • Fins connected to the pipes by interference fit Application: steam air heater OPC

JANKA belongs to the traditional producers of the air-handling units, ventilators, industrial coolers and heat exchangers. The company with its production halls are based in the outskirts of Prague. Thanks to our regional offices and distributors we are present in the Czech republic as well as in other European countries. Division of the Industrial Coolers JANKA ENGINEERING s.r.o. is one of the leading producers of industrial coolers specialized on various types of heat exchangers. These products are used as parts of a variety of machines employed in the industry, energy industry, railway and shipping transportation (e.g. coolers in locomotives, diesel engines, transformers and turbo generators). The exchangers are generally designed for the indoors. However selected products comply with outdoors conditions, explosion prove and also with applications with required seismic resistance. To our business partners such companies as ŠKODA PLZEŇ, ČKD, ALSTOM POWER PBS, ZOS ZVOLEN, SIEMENS, BRUSH SEM belong.

PRODUCT CATEGORIZATION Cooling coils for industrial assembly

Transformer oil coolers Hydrogen coolers Cooling array Coolers PDH Circular air coolers Cooling units

Cooling and heating coils for air-handling units

Water







Steam heater

Heater

OVC

Cooler

CVF

Low pressure High pressure

OPC OPD

Transformer Oil Coolers General Data

Heat transfer surface VPL Cu/Al or Cu/Cu, Wettag Cu/Ms, Cu/Cu or Ms/Ms Supplied assembled Forced air flow ensured by two axial fans 6 standardized capacity versions

Working Medium Main Operation Field Oil cooled by air Forced oil flow required

Cooling of transformer oil by the atmospheric air

Hydrogen Coolers General Data

Heat transfer surface Wettag Cu/Ms, Cu/Cu or Ms/Ms Customized dimensions and capacity

Working Medium Main Operation Field Hydrogen cooled by water Forced water flow required

Cooling of generators and other dynamo electric machinery

Cooling Arrays General Data

Heat transfer surface Wettag Cu/Ms, Cu/Cu or Ms/Ms Customized dimensions and capacity

Working Medium Main Operation Field Compressed air cooled by waterForced water flow required

Cooling of turbocompressors

Coolers PDH General Data

Heat transfer surface Wettag Cu/Ms, Cu/Cu or Ms/Ms Dimensions and capacity given by the size of turbo-charger

Working Medium Main Operation Field Water Sea water Forced water flow required

Cooling of diesel turbo-charged engines

Circular Air Coolers

• Directly on the motorr • Inside of the frame of the motor • Below the motor

General Data

Heat transfer surface VPL Cu/Al, Cu/Cu, Wettag Ms/Fe, Cu/Fe or Cu/Cu Customized dimensions and capacity

Working Medium Main Operation Field Air cooled by water Forced flow of water required

Cooling of generators and turbogenerators Cooling of electromotors

Cooling Units with Flat-oval Tubes General Data

Heat transfer surface Wettag Ms/Fe or Ms/Ms 15 standardized versions

Working Medium Main Operation Field Water cooled by air Forced flow of water required

Cooling of combustion engines Cooling of water circuits in locomotives and stationary engines

Coils for Installation in Ventilation Ducts Water Heaters OVF, Coolers CVF General Data

Heat transfer surface VPL Cu/Al or Cu/Cu 39 sizes ,1-4 rows of heaters and 3-8 rows of coolers

Working Medium Main Operation Field Air cooled or heated by water Forced flow of water required

Air-handling units Air ducts

Steam Heaters OPC and OPD General Data

Heat transfer surface Wettag Fe/Fe, Fe/Al or Water Fin Coils Fe/Al 24 dimension versions, 6 rows

Working Medium Main Operation Field Air heated by steam Forced flow of water required

Air-handling units Air ducts