COOLER PROPANE 12V DC 110V AC

3-WAY PORTABLE ON-GRID • OFF-GRID COOLER PROPANE • 12V DC • 110V AC OWNER’S GUIDE UGP-45L COOLER UGP-55L COOLER with removable DEEPCOLD zone TABL...
Author: Dwain James
7 downloads 0 Views 3MB Size
3-WAY PORTABLE ON-GRID • OFF-GRID

COOLER

PROPANE • 12V DC • 110V AC

OWNER’S GUIDE UGP-45L COOLER UGP-55L COOLER with removable DEEPCOLD zone

TABLE OF CONTENTS 03 Product overview & features 04 Quick start guide 05 Important safety instructions 06 Intended use 07 110V AC operation instructions 08 12V DC operation instructions 09 Gas operation instructions 12 UGP-55L DeepCold zone option 13 Maintenance 14 Troubleshooting check list 15 Technical specifications: UGP-45L 16 Technical specifications: UGP-55L 17 Support and customer service information Warranty information

! GAS SAFETY WARNINGS

Provide ample ventilation, especially when sleeping. This cooler consumes air (oxygen). Do not use this cooler in unventilated structures to avoid endangering your life. Provide additional ventilation for any additional fuel-burning appliances and additional occupants. Do not store chemicals or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. Always operate away from walls and curtains as a fire may occur if it is covered or is close to flammable materials as wall covering, drapes, or other combustible materials. Locate gas cylinder away from the cooler and so that the hose is not kinked becoming a tripping hazard risking personal injury and/or property damage.

! GAS SAFETY WARNINGS If you smell gas: 1. Evacuate enclosure 2. Call for professional help

This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazards and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

KEEP THESE INSTRUCTIONS! 2

READ ALL SAFETY WARNINGS AND OPERATING INSTRUCTIONS CAREFULLY IN ORDER TO GET TO KNOW THIS APPLIANCE BEFORE OPERATING IT.

PRODUCT OVERVIEW & FEATURES 1

2

Interior of UGP-45L

Interior of UGP-55L 3

6

7

8

9

10

11

4

12

5

13

1. Lid handle 2. Carry handle 3. Control panel 4. Gas ignition control 5. Thermostat/temperature control

6. 110V AC power cable 7. 12V DC power cable 8. Gas hose regulators 9. 10 amp fuse 10.110 fuse/replacement fuse in holder

11. Flame indicator 12. AC (red) / DC (green) power source indicator 13. Level eye

IMPORTANT

Place the cooler on a fi rm and level surface. Check that cooler is level and adjust as necessary.

NOTE:

• Cooler performance will be signifi cantly reduced if the fridge is not level. • This is an absorption cooler which means it is silent in operation.

3

QUICK START GUIDE INSTALLATION INSTRUCTIONS

Before using the cooler for the first time, wipe down the appliance inside and out with warm water containing a detergent if necessary. Never use an abrasive product. Dry the cleaned surfaces with a soft cloth. This cooler is designed to operate on one power source at a time. When operating on gas, ensure that both electrical sources are disconnected. When operating on one of the electrical sources, ensure that the other electrical source and the gas supply are disconnected.

NEVER HAVE MORE THAN ONE POWER SOURCE CONNECTED AT ANY TIME

STEP 1

Plug in to a 110V home outlet to pre-chill the empty cooler for up to 6 hours

STEP 2

Keep your food and drinks cool via 12V DC connection while you’re on the road

STEP 3

Propane power keeps your food fresh at the cottage, camp and beyond

• Referencing the integrated level eye, install the cooler on a firm and level horizontal surface. • Avoid installing the cooler in direct sunlight or near any heat source. • Allow a 15 cm/6 inch clearance between the rear of the cooler and any wall or obstruction. • Protect the cooler from rain, water, splashes and inclement weather. • To ensure proper air circulation, do not obstruct the ventilation grids of the upper, lower or rear surface of the cooler. • When using with an electric power source, ensure that the power cord is secured against grabbing, tripping or disconnection that could result in personal injury and/or property damage.

! NOTE: Allow 12-24 hours to achieve full cooling on LP gas or 12V DC power:

- up to 25˚C below ambient temperature for 45L cooler (temp. range of +5˚C to 0˚C) - up to 36˚C below ambient temperature for the 55L cooler (temp. range of +5˚C to 0˚C (cooler section) and +5˚C to -6˚C (DeepCold zone.) Performance of the cooler and DeepCold zone (55L model) will depend on the location of the appliance, the ambient temperature, the frequency of opening and if the food/drink placed within were either warm, cold or frozen.

4

IMPORTANT SAFETY INSTRUCTIONS

!

DANGER

!

USE OUTDOORS ONLY WHEN OPERATING ON PROPANE THIS PRODUCT CAN PRODUCE CARBON MONOXIDE. CARBON MONOXIDE HAS NO ODOUR AND CAN KILL YOU.

! GAS SAFETY WARNINGS

Provide ample ventilation, especially when sleeping. This cooler consumes air (oxygen). Do not use this cooler in unventilated structures to avoid endangering your life. Provide additional ventilation for any additional fuel-burning appliances and additional occupants. Do not store chemicals or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. Always operate away from walls and curtains as a fire may occur if it is covered or is close to flammable materials as wall covering, drapes, or other combustible materials. Locate gas cylinder away from the cooler and so that the hose is not kinked becoming a tripping hazard risking personal injury and/or property damage.

!

GAS SAFETY WARNINGS If you smell gas: 1. Evacuate enclosure 2. Call for professional help

!

ELECTRICAL SAFETY WARNINGS

To reduce risk of electric shock, DO NOT immerse or expose the cooler and the power cord to rain, moisture or other liquids, or use near baths, basins or other water vessels. If any electrical part falls in the water UNPLUG IMMEDIATELY. DO NOT REACH INTO WATER. Prior to reconnecting to power supply, the cooler should be inspected by a qualified technician. Always operate the fridge from a power source of the same voltage, electrical rating as indicated on the rating plate. The cooler must be connected to a grounded 3 pin AC power outlet when operating on AC power.

5

!

IMPORTANT SAFETY INSTRUCTIONS (continued)

• Upon purchase of your cooler, and before every use, inspect it carefully for damage. DO NOT operate if appliance appears to be damaged. In this case return it to the dealer for inspection, replacement or repair. • NEVER stand on the top lid. This may result in personal injury and in damage to the cooler. • DO NOT place any objects on top of lid. • Only operate the cooler from a single energy source. • Proper care should be given not to damage the refrigerant circuit. • DO NOT place or operate this cooler on or near any source of heat. • DO NOT touch cold surfaces of the chilling panel when hands are damp or wet. Skin may stick to surfaces that are extremely cold. • Keep children and pets away from the cooler at all times when in operation. The cooler is not intended for children to operate. • DO NOT use electrical appliances inside the storage compartment. • DO NOT use the refrigerator other than for its intended use. • Never keep flammable liquids and/or gases inside the cooler. Danger of explosion may result. • Only use the cooler in well-ventilated areas. • Do not fill the inner container with ice or fluid. • Only use 5lb (1 gal.) or larger LP-gas cylinders with this cooler. • The LP-gas cylinder used must be constructed and marked in accordance with the Specifications for LP-gas Cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339.

INTENDED USE

The 45L cooler is suitable for cooling food and drinks. The 55L cooler with DeepCold zone is suitable for cooling food and drinks and maintaining (previously) frozen food. Both coolers are suitable for camping, cottage, road-trip and on-site/off-grid use. Both coolers have been designed for operation with a 12V DC voltage source (eg. the cigarette lighter of a vehicle) or alternatively for operation with 110V AC voltage (eg. home outlet.) The coolers can be operated independently of a voltage supply with propane/liquid petroleum gas (LPG).

6

110v AC ELECTRICAL OPERATION INSTRUCTIONS • Referencing the integrated level eye, install the cooler on a firm and level horizontal surface. • When using with an electric power source, ensure that the power cord is secured against grabbing, tripping or disconnection that could result in personal injury and/or property damage. • Check that power source corresponds to voltage specified on cooler rating plate. If the electrical specifications are correct, push the safety electrical plug into a grounded wall socket which is wired according to the specifications. The red AC power indicator light will turn on.

START UP

Turn the thermostat knob clockwise to the MAX position. The effects of the cooling process (frost on the evaporator) only become visible after about an hour. The thermostat enables the temperature of the cooler to be adjustable (“MIN” = cooling process stopped). After a sufficient cooling period (approximately 4-5 hours), the thermostat can be set to an intermediate position for the desired temperature. The selected temperature is regulated automatically by the thermostat.

NOTE: Frequency of lid opening may require higher setting of thermostat. TURNING OFF

Turn control dial counter clockwise to the ‘’OFF’’ position. Remove the cable plug from the wall outlet. Hold the plug to disconnect. DO NOT pull on the cable.

7

12v DC ELECTRICAL OPERATION INSTRUCTIONS RECOMMENDATION

• Pre-cool the refrigerator by running it on 110V before transferring it to the 12V D.C. power source. • When using with an electric power source, ensure that the power cord is secured against grabbing, tripping or disconnection that could result in personal injury and/or property damage. • Check that power source corresponds to voltage specified on cooler rating plate.

START UP

If the electrical specifications are correct, insert the 2-pin plug into the 12V socket at rear of cooler and insert the cigarette plug into the vehicle 12V cigarette lighter socket. The green DC power indicator light will turn on. On DC power the cooler will maintain its pre-chilled temperature within approximately 5-8 degrees for 4-8 hours. There is no temperature regulation when operating on 12V.

TURNING OFF

Remove the plug from the cigarette outlet.

! IMPORTANT: It is recommended to connect the cooler on the 12V DC inlet

only when the vehicle’s motor is running. Do not use the cooler when the motor is not running as this will rapidly discharge the vehicle’s battery.

8

GAS OPERATION INSTRUCTIONS • When operating with propane gas, use the regulated gas hose assembly included with the cooler. • NEVER operate the cooler on a gas supply when driving. E • When operating with gas always use outdoors only. • Locate gas cylinder away from the cooler and so that the hose is not kinked becoming a tripping hazard risking personal injury and/or property damage. • Gas is to be turned off at the propane gas supply when not in use. • Regularly check hose for wear, abrasions and cracks. Replace if necessary.

CONNECTING TO GAS CYLINDER TYPES

A. Indoor and outdoor use This applies to self-contained fuel supplies and using fuel cylinders of not more than 75 cubic inches (1230 cm3) (2.5 lbs nominal water capacity). Fuel supplies shall be in accordance with the Standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA No. 58. The gas supply inlet to a refrigerator is fitted with a nipple and nut conforming with the nipple and nut assembly of Connection No. 600 which will hook directly to your portable camping tank. B. Option - outdoor use only The freezer is designed for a 20# steel propane self-contained fuel cylinder of not more than 4.6 gal (20 lbs) capacity. The cylinder(s) must be constructed and marked in accordance with the specifications for LP-gas cylinders of the U.S. Department of Transportation, DOT SPEC. 39 (49CFR 178.65). This cylinder must be used outdoors in accordance with B149.2-10 Storage and Handling Code.

CONNECTING OF GAS SUPPLY A. UNIVERSAL: Indoor and outdoor use

B. CANADA OPTION ONLY Outdoor use only

A. Indoor and outdoor use 1. Use supplied # 600 connector (#1) and regulator and hose (#3) to connect your appliance (#4) to the gas supply (#3). 2. Tighten #3 to the appliance. 3. Tighten #4 using a backup wrench. 4. After connecting, all gas connections must be checked for leaks. For this, put a soapy solution on all gas connections, turn on the gas cylinder manual valve and watch for bubbles. Never use an open flame to check for leaks. NOTE: The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 11” water column and no less than 10” water 9 column. (Max. setting).

GAS OPERATION INSTRUCTIONS (continued) B. Outdoor use only 5. Use optional regulator and hose to connect your appliance to the gas supply. 6. Hook up the 5/8” - 18UNF connection to the back of your appliance using a backup wrench. 7. Attach the regulator cap to the tank inlet connection and ensure it is tight. 4. After connecting, all gas connections must be checked for leaks. For this, put a soapy solution on all gas connections, turn on the gas cylinder manual valve and watch for bubbles. Never use an open flame to check for leaks. NOTE: The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 12” water column and no less than 11” water column. (Max. setting).

START UP

1. Connect the regulated low-pressure gas hose end to the gas cylinder and the other end at the rear of the cooler. Only use 5lb (1 gal.) or larger LP-gas cylinders with this cooler. 2. Perform a gas leak test to ensure the hose and all connections are gas-tight.

! DANGER OF EXPLOSION ! NEVER USE AN OPEN FLAME TO LEAK TEST. EXTINGUISH CIGARETTES. STAY AWAY OF ANY SOURCE OF IGNITION DURING THIS PROCESS. • Prepare a water and soap solution (70/30% mixture) in a bottle ideally with an applicator brush. • Ensure temperature control is at the ‘’0’’ position, open gas supply at cylinder. • Apply with a brush the solution to all fittings, connections and on the gas hose. • If bubbles form, it indicates a leak. In this case, turn off gas supply, retighten connections. Retest for leaks. If a leak cannot be fixed contact Unique for more information.

GAS VALVE ASSEMBLY

This assembly consists of an adjusting control with an incorporated safety pilot, a burner with an electric igniter. The adjusting control can be set to 3 different positions:

MAX MIN 0 - Off

Maximum cooling Minimum cooling Igniting position/burner gas supply closed

The safety pilot automatically maintains the gas supply to the burner, as long as it remains lit. It automatically shuts off the supply if the flame goes out.

10

GAS OPERATION INSTRUCTIONS (continued)

B

B

C

A

F D

C

E

B

fig. 1

fig. 2

fig. 3

A - Gas ignition control

C - Chimney

D - AC (red) / DC (green) source indicator

B - Temperature adjustment control

E - Level eye F - Flame indicator

LIGHTING

1. Turn temperature adjustment control knob to MAX position (fi g.1). Press and hold down the gas ignition control knob for 20 seconds, allowing system gas line to charge with gas. 2. After 20 seconds, with the knob is fully depressed, slowly turn the knob counterclockwise until your hear the clicking sound of the ignition. 3. Continue to depress the knob for another 20 seconds while the safety gas valve prepares to allow gas fl ow to ignite burner. 4. Check that burner is lit through the view opening at upper rear of COOLER (fi g.2). If the cooler has not been ignited for a long period, or if the gas cylinder has been changed, there may be some air in the gas hose and gas line, so it may fail to ignite. It is necessary to check that the pilot is lit by looking through the orifi ce at the top of the cooler or at the rear on left bottom. If the cooler fails to be ignited, turn off and wait 30 seconds for gas to dissipate and repeat lighting steps. 4. Repeat these steps until cooler is lit (pilot light is visible) and the fl ame indicator points to green (fi g.3). When the outside temperature is low, set the adjusting device to MIN after a suffi cient long cool-down period in MAX position.

TURNING OFF

1. Turn gas valve control fully clockwise to turn OFF. 2. Turn OFF valve at gas cylinder. 3. Disconnect gas hose from cooler, and always before moving it. 4. Disconnect gas hose away from all fl ame and ignition source.

11

55L COOLER WITH DEEPCOLD ZONE Your 55L cooler has two functions, refrigeration and maintaining previously frozen food/drinks in the DeepCold zone. The compartment divider may be removed to accommodate the whole capacity for refrigeration (not for freezing).

Refrigerator

DeepCold zone

GENERAL RECOMMENDATIONS To ensure the utmost performance from your Unique 3-Way Cooler, we recommend following these easy steps:

STEP 1 Plug in to a 110V home outlet to pre-chill the empty cooler for up to 6 hours

STEP 2 Keep your food and drinks cool via 12V DC connection while you’re on the road

STEP 3 Propane power keeps your food fresh at the cottage, camp and beyond

• Pre-chill foods (to cold or frozen) before adding them to the cooler. The 45L cooler will not freeze foods if they are put in warm. The cooler will keep thoroughly chilled foods cold. The DeepCold zone of the 55L cooler will maintain pre-frozen foods, or thoroughly chill cool foods. • The 45L cooler is rated to maintain a temperature 25˚C cooler than ambient temperature. The 55L cooler is rated to maintain a temperature 36˚C cooler than ambient temperature. • Do NOT place the cooler directly in the sun when operating, as this will reduce its effi ciency. • Limit opening the fridge as this will result in temperature loss, reducing the cooler’s effi ciency. • Liquids to be stored in the cooler should always be in closed containers. The air circulation inside the cooler must not be obstructed. • Do not fi ll inner container with ice or fl uid.

12

MAINTENANCE • Clean the cooler regularly with warm water containing a detergent if necessary. Never use an abrasive product. Dry the cleaned surfaces with a soft cloth. Use only clear water to clean the seal of the cover, and then lightly coat the seal with talcum powder. • All repairs, particularily of the cooling unit or the gas burner system must be performed by a licensed technician. • THIS APPLIANCE HAS NO CONSUMER SERVICEABLE PARTS. RETURN TO A GAS DEALER FOR INSPECTION OR REPAIR.

DEFROSTING

To ensure efficient operation, the cooler must be defrosted regularly. To defrost the cooler, disconnect it and remove all food. To help remove any ice build-up, use a cloth soaked in hot water. After de-icing, mop up the water with a clean, dry cloth and wipe down the inside of the unit. Allow all surfaces to dry thoroughly. If the cooler is to remain unused for an extensive period of time (ie: seasonal shutdown), disconnect it and remove all food. De-ice, clean and dry the cooler thoroughly. Store the cooler with the lid slightly open to prevent any off-odors from developing during prolonged storage.

COOLER STORAGE

• Store cooler in a cool, dry and ventilated area, on a stable, level surface. • Protect the cooler while in storage from inclement weather, excessive heat or direct sunlight, water, snow, dust and nesting insects.

SET-UP AFTER LONG-TERM STORAGE

• Wipe down the cooler inside and out with warm water containing a detergent if necessary. Never use an abrasive product. Dry the cleaned surfaces with a soft cloth. • This is an absorption cooler which operates by using a 3 part gas system which, from time to time, may need remixing. If after a long-term storage the cooler does not produce any or enough cooling in an expected amount of time after start-up, disonnect the appliance and turn it upside down for a few minutes then turn it right side up. Do this several times to remix the gas, and reconnect.

GAS CYLINDER STORAGE

• Store the gas cylinder in a cool, dry and ventilated area, protected from sunlight and do not expose to temperatures above 50˚C.

13

TROUBLESHOOTING CHECK LIST If a problem occurs, verify the following: • Check ambient operating temperature. Note: the 45L cooler cools up to 25˚C below ambient temperature, the 55L cooler cools up to 36˚C below ambient temperature. • Is the cooler installed in a horizontal and level position? • Is there sufficient ventilation? • For 110V AC operation, check that the power supply is correct. • Is the thermostat set correctly? • For battery operation, check the battery and the connection. • For gas operation, is the burner ignited? • Have the fuses blown? On the connection panel on the back of the cooler check the 10 amp fuse for DC 12V usage and the 110V glass fuse for 110 AC usage and replace either if necessary. • Has the ignition safety (adjustment) knob been set to MAX? • Are the gas cylinder valve and/or pressure regulator open? • Is there still a sufficient quantity of gas in the cylinder? • Have two modes of energy (gas and electricity) been selected at the same time? • Has too much food been placed inside the cooler all at once? • Arrange the food so that the air is free to circulate inside the cooler. • Do not use pieces of cardboard or plastic as separators. • Keep vessels containing liquids closed.

NOTE: This cooler uses absorption cooling technology and is 100% silent in operation. Allow up to 24 hours for the cooler to acheive lowest temperature.

If the you suspect that the cooler is not functioning correctly, disconnect the cooler, turn it upside down for 2-3 hours and then re-connect it and turn it on.

14

SPECIFICATIONS FOR MODEL UGP-45L MODEL CAPACITY/VOLUME COMPARTMENT DIMENSIONS (W x H x D) CLIMATE CLASSIFICATION INSULATION CLASS REFRIGERANT NET WEIGHT MAIN VOLTAGE RATED CURRENT NOMINAL POWER ENERGY CONSUMPTION BATTERY VOLTAGE RATED CURRENT NOMINAL POWER ENERGY CONSUMPTION PROPANE POWER MINIMUM POWER PROPANE PRESSURE MAX. PROPANE CONSUMPTION OPERATING TIME COOLING CAPACITY

UGP-45L 45 litres / 1.6 cu/ft refrigeration 53cm x 47cm x 47cm 21” x 18.5” x 18.5” N I NH3(80g),H20, He 18 kg/40 lbs 110V 0.74A 82w 1.2kWh/24h DC12V 6.25A 75W 150Ah/24h 520 BTUs/hr 140W 27.4 mbars / 11 inch WC 0.58 lbs./ 24 hrs. Up to 35 days with a 20lbs cylinder +5˚C TO 0˚C • up to 25˚C temp drop than ambient temp

15

SPECIFICATIONS FOR MODEL UGP-55L MODEL CAPACITY/VOLUME COMPARTMENTS DIMENSIONS (W x H x D) CLIMATE CLASSIFICATION INSULATION CLASS REFRIGERANT NET WEIGHT MAIN VOLTAGE RATED CURRENT NOMINAL POWER ENERGY CONSUMPTION BATTERY VOLTAGE RATED CURRENT NOMINAL POWER ENERGY CONSUMPTION PROPANE POWER MINIMUM POWER PROPANE PRESSURE MAX. PROPANE CONSUMPTION COOLING CAPACITY

16

UGP-55L 55 litres / 1.9 cu/ft 2 /3 refrigeration, 1/3 DeepCold zone 64cm x 51.5cm x 53cm 25” x 20” x 21” N I NH3(80g),H20, He 25 kg/55 lbs 110V 1.1A 120w 1.2kWh/24h DC12V 10A 120W 150Ah/24h 560 BTUs/hr 140W 27.4 mbars / 11 inch WC 0.6 lbs./24 hrs. +5˚C TO 0˚C (cooler) +5˚C to -6˚C (DeepCold zone) • up to 36˚C temp drop than ambient temp

CONTACT US For general information or questions related to the operation, safety or the purchase of your cooler, please contact our customer service department: • Toll-free: 1-877-427-2266 or 1-905-827-6154 (available during regular business hours, 8:30am to 4:30pm, EST. • Email: [email protected] Please visit our website for more quality off-grid products: www.uniqueoffgrid.com Unique Gas Products Ltd., 2245 Wyecroft Road, Oakville, Ontario, Canada, L6L 5L7

UGP-45L / 3-WAY COOLER UGP-55L / 3-WAY COOLER WITH DEEPCOLD ZONE 1 YEAR LIMITED WARRANTY Unique Gas Products Ltd., warrants that this UGP-45L/UGP-55L is free from defects in material and workmanship under normal usage and service under the following terms: 1. This Warranty is made only to the first purchaser (“original purchaser”) who acquires this cooler for his/her own use and will be honored by Unique Gas Products Ltd. and by the Seller. 2. Any part of this cooler returned to the Seller or Unique Gas Products Ltd, which upon examination is determined by them to have been defective in material or workmanship, will at their option be either repaired or replaced under this warranty, within 14 days from date of return to Unique Gas Products, without charge for materials/parts. 3. The obligation to repair or replace defective parts will apply only to parts returned within one year of the date of purchase and will constitute the Sellers sole obligation under this Warranty. The Seller will have no obligation under this warranty with respect to conditions unrelated to the material or workmanship of this cooler. Such unrelated conditions include without limitation: a) damage to any part of this cooler caused by misuse, neglect of service or any alteration thereof. b) use of this product for any purpose other than its Intended use. This Unique UGP-45L/UGP-55L cooler must be maintained regularly as outlined in the Owner’s Manual. Unique Gas Products Ltd. and the seller will not be liable for direct or indirect loss of foods caused by failure in operation. In case of failure, the owner must provide proof of purchase, model, and serial number to the seller or Unique Gas Productes Ltd. Please fill out warranty card within 30 days and mail back for warranty coverage.

17

APPLIANCE INFORMATION (manual copy - keep with your records) To make care and servicing of your range easy and efficient, please record the following information for future reference:

Model: Serial Number: Purchased From: Date Purchased: Installed By:

NOTES

18

detatch along dotted line

APPLIANCE INFORMATION (remote copy - keep with your appliance) To make care and servicing of your range easy and efficient, please record the following information for future reference:



Model:



Serial Number:



Purchased From:



Date Purchased: Installed By:



NOTES

detatch along dotted line

19

© 2015 Unique Gas Products Ltd., 2245 Wyecroft Road, Oakville, Ontario, Canada, L6L 5L7 www.uniqueoffgrid.com