Compressed Air section :

• Real-Time monitoring of sensors values. • Data storage on files (text format) . • Settable allarms min. / max for Pressure and Flow with (manual/automatic) outputs • Pitch values indication. • Real time graph for Pressure and Flow with zoom function (30’).



Energy section :

• Total meter (Liters). • Flow averages (L/min, L/h, m3/h). • Electric power required at compressor. • Energy consumption. • Total cost. • Hourly cost.

Easy detect of undued consumptions. . Rigth imputation of energy consumption to the related cost centre.

cat:AM-E-06-11-2-2

• Air-Monitor description • “MAIN” window

Language selector(IT/EN).

Alarm panels for pressure, flow limits values set, alarms reset, otputs status LEDs.

Open info page. Real time graph for Pressure and Flow (values are readed 3 times/sec.). (Orange lines shown alarm low limit values , red line shown alarm high limit value. Data are saved on a text file with the same frequency (3 times/sec), a new file is generated every 24 h.

Virtual gauge Blue indicator: Actual Pressure Orange indicator: Low alarm Red indicator : High alarm. Indicatori valori di picco minimo e massimo con reset. Virtual Flow-Meter Green indicator: Actual Flow Orange indicator: Low alarm Red indicator : High alarm. Pitch values indicators min/max with reset. Data storage filename. Saving current settings. Graph zoom function (30’).

Demo function, allow to test the Sw. whithout a Air-Meter equipment installed. Virtual data are generated by the sw. to simulate a true compressed air line.

• “ENERGY” window Current Data and Time

Data and time at starting time or at last reset, and elapsed time.

Timer and Counters Reset Air flow rate (L/min) of compressor for Kw of installed electric power. Input field.

Total flushed liters in the elapsed time. Average flow in several units.

Hourly cost of electric energy. Input field.

Total of energy cost for the elapsed time.

Electric power required from this line at the compressor.

Total energy consumption in the elapsed time. Hourly cost of energy.

• “I/O” window

• “Zoom” windows

Display of sensors signals values, USB link status, setiing of output mode, Automatic or Manual: Automatic: outputs (5V) are working according with alarms LEDs status on “MAIN” windows. Manual: outputs are drived by push buttons on I/O window.

Zoom function show real time graph for Pressure and Flow with the last 30 minutes of registered values.

Air-Meter SW4000 Series

Sensorized (Flow & Pressure sensors ) Air-Treatment equipments , with USB interface. Port: 1/2”, applicable flow up to 4500 L/min. Monitoring system for compressed air line, small investment with immediate results, Air-Monitor Sw. licence included . Air-Meter SW4000

3. Code 1 Options Drain - F Bowl - Z M

SW4000 - 15G - W - * - B3W - * * 2

1 = Manual = Automatic = Policarbonate = Nylon = Metal

Element - Y* Regulator - N L

= 5 micron = 0.3 micron = Std. w. built-in gauge = Nonrelief type = Low pressure (0.5 - 3.5 bar)

2 Electric supply - = 24VDC (cable length 1.5 mt.) CA = C.A. adapter plug attached 100/240V-50/60Hz.

1. General description Sensorized FR equipment allow, with a small investment , full monitoring and data aquisition of the compressed air lines, with a flow rate up-to 4500 L/min. (Equivalent to a compressor size ~30Kw) Integrated filter/regulator with bracket allows a quick installation and full protection of sensors and connected lines or machines.

USB interface. Software Air-Monitor included. Data stored on text file editable with common text editor or spreadsheet programs. Easy installation. Small investment, immediate results. Measure, regulation and filtration in a single equipment. Alarms outputs (5V) for Pressure and Flow low / high limits, with manual override.

CKD

Modular with FRL s3000, 4000 and CXU Series.

2. Symbol • •

Pressure

Flow

• •

Sensorized Filter/regulator

4. Features PC interface S.O. Include software Data file format and mode Required Hw. Processor RAM Screen resolution HD space required by Sw. HD space required by Data file Max pressure Proof pressure Applicable temperature range Filtration Pressure regulation Relief sensivity Bowl volume Max mesurable flow Pressure sensor precision Flow sensor features Linear characteristic Pressure characterstic Temperature characterstics Port Fixing braket: Mass

:USB 1.1 / 2.0 :Win XP, Vista, Seven :Air-Monitor :TXT files, 1 new file every 24 h. :Pentium 4/M and over / equivalent :1 GB (min) :1024 x 768 (min) :4 MB :~0,2 Mb/h :1.0 MPa :1.5 MPa :50C - 600C :5 micron std. / 0.3 micron opz. :0.05 - 0.85 MPa (0.05 - 0.35MPa L type) :Set pressure + 0.05 MPa :80cm3 :4500 L/min. : +/-1% f.s. : better than ±5% f.s. (free flow, 25°C) : better than ±5% f.s. (free flow) : better than ±0.2 % f.s (15~35°C ref. 25°C) :Body port 1/2” :included :1,8 Kg (2Kg whit CA adapter )

Air-Meter SW4000 Series 5. Main dimensions *1

40~75 screw ø 6mm Fissaggio 40~75 viti max. ø max 6mm

5

x 97,

Hmax 284

Pma

IN 1/2”

60mm free, Lasciare 60mm per forsfilare maintance. per la coppa.

OUT 1/2”

Lmax 175

nota *1: For fothers dimensions of Filter-Regulator and accessories a please consult FRL General catalog.

Air-Meter AMB-08 Series

Flow and Pressure sensors with USB interface Ports up-to 2”, measurable flow up-to 16000 L/min. Monitoring systems for compressed air lines, high precision and appropriate sensors for a wide range of flow rate , Air-Monitor Sw. licence included. 3. Code

AMB-08 - PE - * * * * * * - * * 1

2

1 Measurable flow F.S. (L/min) , sensor type. 005 = 0,5 , FSM2 101 = 100 , FSM2 010 = 1 , FSM2 201 = 200 , FSM2 020 = 2 , FSM2 501 = 500 , FSM2 050 = 5 , FSM2 102 = 1000 , FSM2 100 = 10 , FSM2 2000F = 2000 , PF 200 = 20 , FSM2 4000F = 4000 , PF 500 = 50 , FSM2 8000F = 8000 , PF-L 16000F = 16000 , PF-L 2 Electric supply - = 24VDC (cable length 1.5 mt.) CA = C.A. adapter plug attached 100/240V-50/60Hz.

1. General description AMB-08 series offer high precision flow and pressure sensors with USB interface, this solution allow quick installation of monitoring systems on a wide range of sizes of compressed air lines in combination with software Air-Monitor included in the package. CKD sensors, with short response time, and direct mesurement of 100% of flow allows a high precision of collected data. USB interface. Software Air-Monitor included. Data stored on text file editable with common text editor or spreadsheet programs. Easy installation. High precision. Wide range of flow sensors, to meet each flow rate range. Limited investment, immediate results Alarms outputs (5V) for Pressure and Flow low / high limits, with manual override.

4. Features *1 PC interface :USB 1.1 / 2.0 S.O. :Win XP, Vista, Seven Include software :Air-Monitor Data file format and mode :TXT files, 1 new file every 24 h. Required Hw. Processor : Pentium 4/M and over / equivalent RAM : 1 GB (min) Screen resolution :1 024 x 768 (min) HD space required by Sw. : 4 MB HD space required by Data file : ~0,2 Mb/h Max. pressure : 0.7MPa Sens. FSM2 / 1.0 MPa Sens. PF Proof pressure : 1.0 MPa Sens. FSM2 / 1.5 MPa Sens. PF Applicable temperature range : 00C - 500C Measurable flow F.S. : 0,5 ~ 16000 L/min. Pressure sensor precision : +/-1% f.s. (PPE-A sensor) Flow sensor features: Linear characteristic : Sens.FSM2 better than ±3% f.s. (free flow, 25°C) : Sens.PF better than ±1.5% f.s. (0,7MPa, 20°C) : Sens.PF-L better than ±2.5% f.s. (0,7MPa, 20°C) Pressure characterstic : Sens.FSM2 better than ±5% f.s. (free flow) : Sens.PF better than ±1.5% f.s. (0.1~1.0MPa rif. 0.7Mpa) : Sens.PF-L better than ±1.5% f.s. (0.1~1.0MPa rif. 0.7Mpa Temperature characterstics : Sens.FSM2 better than ±0.2 % f.s (15~35°C rif. 25°C) : Sens.PF better than ±2 % f.s (0~40°C rif. 20°C) : Sens.PF-L better than ±2 % f.s (0~40°C rif. 20°C) note *1: Pls. refer to specific catalogs for full features of sensors.

Serie

Air-Meter AMB-08

5. Ingombri box interfaccia USB *2 

52,7

8 23,

L cavo = 1.8 m

nota *2: For dimensions of Flow and Pressure sesnors please consult related catalogs.

• Catalogs of related equipments, equivalent catalogs are available in english language.

Flow Sensors FSM2 Series

Flow Sensors PF Series

Air Treatment General Catalog

Pressure sensors PPE-A Series

epsitec automazione pneumatica CKD

c.a.p.50041 Calenzano - FIRENZE Via Fibbiana, 15 Telefono 055 - 8825359 - 8827376 - 8827546 Fax 055-8827376 e-mail [email protected] Home:WWW.CKD.IT

Air-Monitor e Air-Meter Are products deigned, developed and assembled by epsitec s.r.l. features may change whitout notic

Rivenditore di zona :