GE Energy

3.3kV-27kV Embedded Pole Vacuum Circuit Breaker Leading the future of electrification

3.3kV-27kV Embedded Pole Vacuum Circuit Breaker Leading the future of electrification

GE GE is a diversified organization covering a myriad of market segments, including infrastructure, finance and media. From energy, water, transportation and health to access to money and information, GE serves customers in more than 100 countries and employs more than 300,000 people worldwide. The company traces its beginnings from Thomas A. Edison, who established the Edison Electric Light Company in 1878. In 1892, a merger of Edison General Electric Company and Thomson-Houston Electric Company created the General Electric Company. GE is the only company listed in the Dow Jones Industrial Index today that was also included in the original index in 1896.

Industrial Solutions GE Industrial Solutions, a division of GE Energy, is a global leading provider in power distribution, offering a wide range of services and products which include medium and low voltage power distribution equipment and components, motor & control systems and service products that are safe, reliable and offer high performance.

Honour 2010 World's Most Innovative Companies 2011 World’s Most Admired Companies 2009 World’s Most Respected Companies 2011 Best Global Brand

2008 World’s Most Respected Companies

2007 World’s Best R&D Companies

80

More Than 80 Years of Interrupter Experience GE pioneered experimental vacuum interrupters in the 1920s. Refined it and introduced the world's first 15kV Vacuum circuit breaker in the 1960s, To date, this interrupter design has been the world leader in vacuum technology and has accumulated over 45 years of reliable field service.

A World Class Quality Manufactured, assembled and tested all in the same sophisticated facility, SecoVac is the product of state of the art manufacturing processes assured by ISO 9001:2008 and ISO 14001 certification. Precision tooled parts, computer aided design and advanced production techniques, as well as the protection of the 'E Coat' (cathodic electrocoating) paint process have resulted in a standard of excellence unmatched in the industry.

eco

Universal Applications SecoVac is designed, assembled and tested to meet or exceed applicable IEC, GB and DL standards. It is suitable for applications in all major industries including T&D, Oil & Gas, Automotive, Processing plants, Iron and Steel mills, Mining, Commercial buildings, etc. It provides protection for all types of applications: coble, overhead lines, motors, capacitors, transformers, busbar sections, etc.

Environment Conscious Selecting low environmental impact technologies has become increasingly important to engineers tasked with choosing equipment for an application. With commitment to environment protection, the solid insulation of epoxy resin is used for SecoVac series MV embedded pole vacuum circuit breaker instead of SF6 gas.

Contents General Introduction GE GE Industrial Solutions

Description Brief Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 Vacuum Interrupter (VI) . . . . . . . . . . . . . . . . . . . . . . . 04 Application Condition . . . . . . . . . . . . . . . . . . . . . . . . . 05 Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06 Advanced Technology . . . . . . . . . . . . . . . . . . . . . . . . 08 Standards and Quality Control . . . . . . . . . . . . . . . . 08 Environmental Protection . . . . . . . . . . . . . . . . . . . . . 10

Selection Guide Introduction and Type Description . . . . . . . . . . . . 12 Product Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Primary disconnect . . . . . . . . . . . . . . . . . . . . . . . . 12 Breaker mechanism . . . . . . . . . . . . . . . . . . . . . . . 12 Interlock system . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Typical layout for vacuum circuit breaker . . . 13 Spare parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Electric parameter . . . . . . . . . . . . . . . . . . . . . . . . . 14 Overall dimension . . . . . . . . . . . . . . . . . . . . . . . . . 14 SecoVac VB2 Plus L-frame . . . . . . . . . . . . . . . . . 19

Measurement, Protection and Control Multilin 650 Family . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Multilin 3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Operation Internal Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . 28 Working Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Vacuum interrupter . . . . . . . . . . . . . . . . . . . . . . . . 30 Working principle of operating mechanism . . . . 30 Spring motor spring charging . . . . . . . . . . . . . . 30 Closing operation . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Anti-Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Tripping operation . . . . . . . . . . . . . . . . . . . . . . . . . 31 Reclosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Interlocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Check

Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Preparation Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Description

Introduction

02

SecoVac series 3.3kV-27kV vacuum circuit breaker designed by GE is a three-phase AC indoor breaker with 3.3kV-27kV rated voltage and can be applied in controlling and protecting electrical equipment in industrial and mineral enterprises, power plants and substations. The product conforms to the IEC 62271 standard. It is especially suitable for conditions which require frequent operation. The breaker can be installed in the switchgear both in fixed type and withdrawable type. It is the optimum choice for the control and protection of MV power distribution systems.

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Reliability, safety and performance in a compact package

Leading vacuum and insulation technology

Built to highest quality standards

Reliability and safety

GE has developed environmentally

SecoVac circuit breakers are designed

SecoVac circuit breakers have a number

friendly vacuum circuit breakers which

and fully third-party type tested to the

of inbuilt safety capabilities which can be

are capable of reliably switching high

latest IEC 62271-100 and IEC 62271-1

incorporated into the switchgear design.

stress fault currents. Increased dielectric

standards. All SecoVac circuit breakers

Due to its innovative operating

strength of the SecoVac circuit breaker

meet or exceed the electrical and

mechanism the SecoVac breaker has

is achieved through encapsulation of

mechanical endurance requirements of

industry leading reliability that is rated at

the vacuum interrupter in epoxy resin

E2 and M2 in accordance with IEC 62271-

10,000 operations.

material. SecoVac circuit breaker family

100.

Description

SecoVac 3.3kV-27kV Vacuum Circuit Breakers Provide:

utilizes this solid insulation technology that has been catering to a wide scope of applications for years.

Adaptability and versatility SecoVac circuit breakers can be used in a

Environmentally-friendly design

Storage conditions

wide scope of applications such as the

In order to retain all of the functional

protection of transformers, capacitor

units qualities when stored for prolonged

banks, motors. The breaker can be used

periods, we recommend that the

in a wide range of environments to suit all

equipment is stored in its original

regions of the globe.

GE’s vacuum and solid insulation

packaging in dry conditions sheltered

technology is free of SF6 gas that

from the sun and rain at a temperature

contributes significantly to the greenhouse

of between -15°C and 40°C. For storage:

effect and associated climate change.

-30°C. 03

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Vacuum Interrupter (VI)

Maintenance free GE vacuum interrupters are hermetically sealed and offer extensive vacuum integrity. Dedicated to proven reliability, safety and performance, GE vacuum

Description

interrupting technology offers highest quality products which are sealed for life.

Structural durability At the heart of the 3.3kV-27kV IEC circuit breaker portfolio is GE’s proven vacuum interruption technology and eighty years of expertise in this field.

SecoVac circuit breaker is an embedded pole type, which is extremely durable. It can protect the vacuum interrupter from mechanical and climatic influence such as humidity, moisture and dust.

The vacuum interrupter is where current making and

The interrupter is immune to shock and

breaking occurs. Copper chromium contacts provide

vibration.

superior performance characteristics. The vacuum in the arc chamber protects the copper chromium contacts from adverse effects such as contamination and corrosion.

High performance SecoVac circuit breakers provide you with: ●● High dielectric strength ●● High creepage distance ●● High mechanical strength ●● Low moisture absorption ●● Optimum thermal conductivity

Compact size Combined with GE's embedded pole technology, SecoVac circuit breaker has a very compact design. It offers high current and interruption ratings in a small, cost effective package.

04

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Special application condition

●● The ambient air temperature does not

If the actual application conditions differ

exceed 40°C and its average value,

from the normal application conditions,

measured over a period of 24 hours,

circuit breaker and associated devices

does not exceed 35°C. The minimum

and auxiliary equipment shall be designed

ambient air temperature is –15°C

and manufactured to comply with any

(storage and transportation is allowed

special application conditions. For special

at -30°C)

application conditions please consult with

●● For applications above 1,000m please

GE in advance, normally the following

refer to chapter 4.2.2 of IEC 60071-2

special service conditions maybe

(see following table for reference)

encountered:

●● The conditions of humidity are as

●● The installation location is more than

follows:

1,000m above sea level ●● The ambient temperature is between

- The average value of the relative humidity, measured over a period of

-15°C and 40°C, for other conditions

24 hours, does not exceed 95%

please contact GE sales for further detail

- The average value of water vapor

●● The circuit breaker current and

pressure, measured over a period of

dielectric ratings must be lowered for

24 hours, does not exceed 2.2kPa

high altitude and elevated temperature

- The average value of the relative

applications

humidity, measured over a period of one month, does not exceed 90% - The average value of water vapor pressure, measured over a period of one month, does not exceed 1.8kPa ●● Seismic intensity to UBC zone 4 or GB

intensity 9 ●● No adverse operating environment

such as dust, humidity, vermin, polluted ambient and high altitude operating site

m 1,000 1,500 2,000 2,500 3,000 3,500 4,000

Altitude Derating MV K (m=1) V 1 1 1.062 0.94 1.132 0.88 1.2 0.83 1.28 0.78 1.36 0.74 1.44 0.69

K (m=0.9) 1 1.056 0.12 1.18 1.246 1.32 1.39

In 1 0.95 0.89 0.85 0.80 0.76 0.72

IEC 60071-2, 4.2.2 the altitude correction factor can be calculated using the following equation, which modified to reflect that no correction is required up to 1000m.

Kа=e Where H Is the altitude, in metres m Is taken as a fixed value in each case for simplification as follows m = 1 for power frequency, lightning impulse and phase-to-phase switching impulse voltages m = 0.9 for longitudinal switching impulse voltages m(H-1000)/8150

Description

High performance

Environment

Application Condition

05

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Applications

Utilities and power plants Power generation stations Transformer stations Switching stations

Description

Main and auxiliary switchgear

Industry Oil and Gas Mining Marine Pulp and Paper Cement Textiles Chemicals Automotive Petrochemical Data Center Metallurgy

Transport Airports Ports Railways Underground transport

Services Supermarkets Shopping malls Hospitals Large infrastructures and civil works

06

Description

Applications

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

07

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Advanced Technology

Standard and Quality Control

High adaptability ●● Compare to traditional design,

enhanced reliability ●● Less resistance ●● Less mechanical parts ●● Various applications for different

Description

climates

Quality

Type test

SecoVac circuit breakers provide you with:

●● Dielectric test

●● IEC standard, 3rd party KEMA

●● Temperature rise test

certification ●● Advanced manufactoring process

ensured quality ●● Advanced testing equipment

Mechanical structure

●● Withstand current test ●● Mechanical operation test ●● ES-Mechanical operation test ●● Capacitive current switching test

●● Integrated routing test

●● Single modular design ●● Integrate closing/opening module ●● Compact size, less than 86 parts ●● Enhanced reliability ●● Low maintenance

Standard 3.3kV-27kV Embedded Pole Vacuum Breaker complies with the standards and specifications and has been type tested

earth switches ●● IEC 62271-1:2007 the common

in accordance with the following IEC

specification for high voltages

publications:

switchgear and control gear standards

●● IEC 62271-100:2008 high-voltage

alternating current circuit breaks ●● IEC 62271-200:2003 AC metal enclosed

switchgear and control gear for rated voltages above 1kV and up to 52kV 08

●● Alternating current disconnector and

●● IEC 60529:2001 degrees of protection

as provided by enclosures (IP code)

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Gelation) technology and advanced vacuum mixing and degassing technology. The Vogel clamping machine is an essential piece of equipment to ensure the mechanical and insulating strength of the embedded pole of 3.3kV-27kV series MV embedded pole vacuum circuit breaker. As well as the processing facilities, the testing facilities are also very important to the quality control of the breaker. In the manufacturing process of SecoVac, from incoming material quality control to the final inspection and testing, every step is strictly calibrated and tested. Every embedded pole goes through the following inspection and testing before it is allowed into the breaker assembly line: ●● X-ray inspection ●● Power frequency withstand voltage test ●● Partial discharge measurement ●● Thermal cycling test

g

GE Energy Industrial Solutions 1) Each position for withdrawable units shall be clearly indicated. The operation 3.4 shall be flexible and reliable. 2) Functional units with same type and same size should be interchangeable

Routine tests Report(MV switchgear) Project Name

Contract No.

Type

Serial No. Rated Normal Current

Rated Voltage Breaker No. Applicable Standards:

___________kV

IEC62271-200: 2003

Item No. Description 1 1.1

Result

4

□Pass □Fail

5

Insulation resistance between main circuit and earth after Power-frequency withstand voltage test:__________Ω .

□Pass □Fail

6

Power-frequency withstand voltage test of auxiliary circuit. __________kV, 1s, without breakdown

□Pass □Fail

7

Actual electrical connection, including auxiliary switches and meters, should comply with diagrams. Operation test should be correct. (sample check of polarity, ratio)

□Pass □Fail

8

Resistance measurement of main circuit Phase A(L1)______________μΩ Phase B(L2)______________μΩ Phase C(L3)______________μΩ

□Pass □Fail

9

Inspection of protection degree(IP_______).

10

Cleanliness check (dust & impurities are not allowed)

Remark

Structure inspection Check overall dimensions, Coating, electroplating.

□Pass □Fail

Right installation of components. Mark, 1.2 size, amount and nameplates, etc. should comply with requirement of drawings.

□Pass □Fail

Arrangement and main circuit connection should comply with single-line diagrams 1.3 provided by customer and technical specification.

□Pass □Fail

2

Checking of torque for main busbar joint shall meet the requirement.

3

Mechanical characteristics and mechanical operation test

Close and open breaker 5 times repeatedly without malfunction; 3.1 Repeat inserting and drawing out truck unit 5 times without malfunction. 3.2

□Pass □Fail

Insulation resistance between main circuit and earth before Power-frequency withstand voltage test :________Ω Power-frequency withstand voltage test of main circuit. Ambient temperature__________℃ Relative humidity ____________% 1) Phase to phase, phase to earth __________kV, 1min, without breakdown. 2) Across the isolating distance __________kV, 1min, without breakdown.

__________ A

Conclusion Inspector/ Date

Inspect anti-pumping function of breaker 3 times repeatedly.

1) Mechanical characteristic of main C.B. should meet the technical specification. Repeat charging the breaker 3 times, under 85% and 110% rated voltage respectively without malfunction. 2) The breaker should not be tripped below 30% rated voltage, 3 times 3.3 repeatedly. the range of control voltage for circuit breakers are as follows:85%~110% rated voltage, circuit breaker should be reliably closed; 70%(DC) / 85%(AC)~110% rated voltage, circuit breaker should be reliably opened; 3 times repeatedly.

□Pass □Fail

□Pass □Fail □Pass □Fail

11 Accompanying documents all ready. 12 Spare parts all ready.

□Pass □Fail

□Pass □Fail

Operate mechanical interlock device 5 times, without failure.

3.5

13 Accessories all ready.

□Pass □Fail □Pass □Fail □Pass □Fail □Pass □Fail □Pass □Fail

Remarks

Before delivery, the following tests and inspections will be done for 3.3kV-27kV embedded pole vacuum circuit breakers in factory by means of advanced testing equipment: ●● Dynamic characteristics measurement (Closing/opening speed, contact bounce, wipe

etc.) ●● Power frequency withstand voltage testing ●● Inspection of interlocking system between breaker and withdrawable unit ●● Secondary wiring inspection ●● Circuit resistance measurement

Description

The high quality of the embedded pole is achieved by using the latest APG (Auto Pressure

Quality Control

The state-of-the-art processing and advanced quality control

09

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Environmental Protection Selecting low environmental impact technologies has become increasingly important when choosing equipment for an application. With commitment to environment protection, the solid insulation of epoxy resin is used for 3.3kV-27kV series MV embedded pole vacuum circuit breaker instead of SF6 gas. Manufactured, assembled and tested all in the same sophisticated facility, SecoVac is the product of state-of-the-art manufacturing

Description

processes assured by ISO 9001:2000 and ISO 14001 certification.

10

Using precision tools, computer-aided design and advanced production techniques.

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Selection Guide Introduction and Type Description . . . . . . . . . . . . 12 Product Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Typical layout for vacuum circuit breaker . . . 13 Spare parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Electric parameter . . . . . . . . . . . . . . . . . . . . . . . . . 14 Overall dimension . . . . . . . . . . . . . . . . . . . . . . . . . 14 SecoVac VB2 Plus L-frame . . . . . . . . . . . . . . . . . 19

Selection Guide

Primary disconnect . . . . . . . . . . . . . . . . . . . . . . . . 12 Breaker mechanism . . . . . . . . . . . . . . . . . . . . . . . 12 Interlock system . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

11

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Selection Guide Introduction and Type Description Up to 17.5kV SecoVac



SecoVac Series Rated voltage: VB2 Plus vacuum 7.2kV, 12kV, circuit breaker 15kV, 17.5kV

/T

Spring operating mechanism

24kV, 27kV SecoVac



SecoVac Series Rated voltage: VB2 Plus vacuum 24kV, 27kV circuit breaker

/T

Spring operating mechanism

ŕ-

Rated current (A): 630, 1250, 1600, 2000, 2500, 3150, 4000* (*force cooling)

ŕ-

Rated current (A): 630, 1250, 2000, 2500

ŕ

Rated short-circuit breaking current (kA): 25, 31.5, 40

ŕ

W: Withdrawable; F: Fixed

ŕ

Rated short-circuit breaking current (kA): 25, 31.5

ŕ

W: Withdrawable; F: Fixed

Selection Guide

Product Structure

12

SecoVac 3.3kV-27kV Breaker Features

Front panel

Primary disconnect

Breaker mechanism

Front panel fits into a collar frame in the

The primary disconnect cycloid (tulip)

All the mechanical parts of the mechanism

equipment when the breaker is in the

contact set is rugged and easy-to-inspect.

are integrated into individual opening

connect position. It provides a metal

Designed for optimum contact area,

and closing modules. The modules are

barrier between the breaker compartment

it is manufactured from silver-plated

universal to SecoVac embedded pole

and the secondary device compartment.

copper and tested for continuous and

vacuum circuit breaker series, regardless

Clearly marked and easy-to-read

short-circuit current ratings. The tulip

of rating. The module design assures no

operating controls and indicators include

cluster design expands easily, providing

mechanical adjustment is required after

trip button, close button, open/close

better finger contact area than flat type

replacement. This offers the user shorter

indicator, charge/discharge indicator,

contact designs, and delivering proper

lead-times and reduces operational and

operations counter and provision for

contact integrity throughout the life of the

maintenance costs.

manually charging the breaker.

equipment.

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Interlock system

Undercart

For personnel safety, SecoVac 3.3kV-27kV

SecoGear offers manual operation

is designed with a number of mechanical

undercart system which can be operated

and electrical interlocks. For example,

for racking in and out. The undercart has

breaker contacts must be open before

an interlock with earthing switch, which

the breaker can be moved from test to

prevents misoperation. And it also allows

connected position. A positive mechanical

earthing function of circuit breaker by

stop is provided when the breaker

means of metallic structure.

reaches the connect or test/disconnect positions. Mechanical rejection interlocks are provided to permit only the insertion of properly rated breakers into specific compartments. These and other necessary interlocks provide a comprehensive safety system. Furthermore, springs automatically discharge when the breaker is withdrawn from the connect position and breakers

Typical layout for vacuum circuit breaker

1

Tripping button

2

Status indicator for charging

3

Closing button

4

Counter

5

Indicator for open or close

6

Charging handle

1 3 2

4 5

Selection Guide

cannot be inserted in the closed position.

6

Figure 1. Front facial of the circuit breaker

1 1

Upper contact arm

2

Embedded poles

3

Lower contact arm

4

Tulip cluster

2 3 4

Figure 2. Primary circuit

13

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Spare parts The following spare parts are available to be ordered. If required please contact GE. Description Auxiliary switch F10-18 Auxiliary switch GDF-5 Trip coil Position coil Micro Position switch Energy charge motor

Remarks 1 part per breaker 2 parts per breaker 1 part per breaker 1 part per breaker 3 parts per breaker 1 part per breaker

Description Counter Oil buffer Control wiring board Electromagnet for locking Electromagnet for locking truck

Remarks 1 piece per set 1 piece per set 1 piece per set 1 piece per set 1 piece per set

Selection Guide

Electrical parameter Rated Voltage

kV

Rated Current

A

Frequency Rated Power Frequency Withstand Voltage (1min) Rated Lightning Impulse Withstand Voltage (Peak Values) Rated Short Circuit Breaking Current Rated Short Time Withstand Current (3s) Rated Peak Withstand Current Rated Peak Making Current Capacitor Bank Switching Current Electrical Endurance Mechanical Endurance Rated Auxiliary Control Voltage Opening Time Closing Time

3.3~12

15

17.5

24

630/1250/1600/2000/ 2500/3150/4000*

Hz kV kV kA kA kA kA A No. of times No. of times V ms ms

50/60 36 95 25/31.5/40 25/31.5/40 65/82/104 65/82/104

28 75

27

630/1250/1600/2000/2500 38 95

488

50/60 65 125 25/31.5 201.5 25/31.5 65/82 65/82

400 (C2) E2 10,000 (M2) 36/48/60/110/220/240 V DC 110/220 V AC 20~50 30~70 e

户内高压真空断路器

Vacuum circuit breaker GE Consumer & Industrial Systems 产 品 型 号 Type designation 出 厂 编 号 Serial number 额 定 电 压 kV Rated voltage(Ur) 额 定 电 流 A Rated normal current(Ir) 额 定 频 率 Hz Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) kV Rated lightning impulse withstand voltage(Up) 额 定 短 路 开 断 电 流 kA Rated short-circuit breaking current(Isc) 额 定 短 时 耐 受 电 流 kA Rated short time withstand current (4s) 额 定 电 缆 充 电 开 断 电 流 A Rated cable-charging breaking current 电 机 电 压 V motor voltage 分 闸 合 闸 装 置 电 压 V Rated supply voltage of closing and opening devices 执 行 标 准 Relevant standarder 额 定 操 作 顺 序 O-0.3s-CO-180s-CO Rated operating sequence 重 量 kg Weight 出 厂 日 期 Manufacture date

Overall dimension

注意!

高压危险!请严格遵守操作规程。 Warning! High voltage dangerous! Always observe the instruction manual and follow the rules.

上 海 通 用 电 气 开 关 有 限 公 司 Shanghai GE Breakers Co.,Ltd.

SecoVac 3.3kV-17.5kV/630~1250A-25~31.5kA (Phase to phase distance: 150mm) 502 516 531

Withdrawable type 488

488 201.5

201.5

637

637

275±1

275±1

ØD

ØD

150±1

e

78

280±1

注意!

高压危险!请严格遵守操作规程。 Warning! High voltage dangerous! Always observe

户内高压真空断路器

95.5

the instruction manual and follow the rules.

上 海 通 用 电 气 开 关 有 限 公 司 Shanghai GE Breakers Co.,Ltd.

kV kA kA A V

注意!

V

高压危险!请严格遵守操作规程。 Warning!

O-0.3s-CO-180s-CO

436±1

High voltage dangerous! Always observe

kg

the instruction manual and follow the rules.

上 海 通 用 电 气 开 关 有 限 公 司

32

Shanghai GE Breakers Co.,Ltd.

502 150±1

492±1 456

516 531

150±1

14

492±1 456

76

502 516 531

599±1

436±1 150±1

150±1

599±1

95.5

A

78

kV

Hz

76

产 品 型 号 Type designation 出 厂 编 号 Serial number 额 定 电 压 Rated voltage(Ur) 额 定 电 流 Rated normal current(Ir) 额 定 频 率 Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) Rated lightning impulse withstand voltage(Up) 额 定 短 路 开 断 电 流 Rated short-circuit breaking current(Isc) 额 定 短 时 耐 受 电 流 Rated short time withstand current (4s) 额 定 电 缆 充 电 开 断 电 流 Rated cable-charging breaking current 电 机 电 压 motor voltage 分 闸 合 闸 装 置 电 压 Rated supply voltage of closing and opening devices 执 行 标 准 Relevant standarder 额 定 操 作 顺 序 Rated operating sequence 重 量 Weight 出 厂 日 期 Manufacture date

280±1

e

户内高压真空断路器

Vacuum circuit breaker GE Consumer & Industrial Systems 产 品 型 号 Type designation 出 厂 编 号 Serial number 额 定 电 压 kV Rated voltage(Ur) 额 定 电 流 A Rated normal current(Ir) 额 定 频 率 Hz Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) kV Rated lightning impulse withstand voltage(Up) 额 定 短 路 开 断 电 流 kA Rated short-circuit breaking current(Isc) 额 定 短 时 耐 受 电 流 kA Rated short time withstand current (4s) 额 定 电 缆 充 电 开 断 电 流 A Rated cable-charging breaking current 电 机 电 压 V motor voltage 分 闸 合 闸 装 置 电 压 V Rated supply voltage of closing and opening devices 执 行 标 准 Relevant standarder 额 定 操 作 顺 序 O-0.3s-CO-180s-CO Rated operating sequence 重 量 kg Weight 出 厂 日 期 Vacuum circuit breaker GE Consumer & Industrial Systems Manufacture date

32

492±1 456

150±1

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Fixed type ∅62

Terminal section 150

150

275

M16 Depth 22mm

838

451.5 GE Engery

Industrial Solutions 产 品 型 号 Type designation 出 厂 编 号 Serial number 额 定 电 压 Rated voltage(Ur) 额 定 电 流 Rated normal current(Ir) 额 定 频 率 Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) Rated lightning impulse withstand voltage(Up) 额 定 短 路 开 断 电 流 Rated short-circuit breaking current(Isc) 额 定 短 时 耐 受 电 流 Rated short time withstand current (3s) 额 定 电 缆 充 电 开 断 电 流 Rated cable-charging breaking current 电 机 电 压 motor voltage 分 闸 合 闸 装 置 电 压 Rated supply voltage of closing and opening devices 执 行 标 准 Relevant standarder 额 定 操 作 顺 序 Rated operating sequence 重 量 Weight 出 厂 日 期 Manufacture date

376.5

户内高压真空断路器

Vacuum circuit breaker

kV

4-M12

A Hz kV kA

237

e

kA A V V

注意!

高压危险!请严格遵守操作规程。 Warning!

2V&2V&2 2V&2V&2 kg

High voltage dangerous! Always observe the instruction manual and follow the rules.

上 海 通 用 电 气 开 关 有 限 公 司 Shanghai GE Breakers Co.,Ltd.

370 450

275

45

118

443

e

户内高压真空断路器

GE Consumer & Industrial Systems 产品型号 Type designation 出厂编号 Serial number 额定电压 Rated voltage(Ur) 额定电流 Rated normal current(Ir) 额定频率 Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) Rated lightning impulse withstand voltage(Up) 额定短路开断电流 Rated short-circuit breaking current(Isc) 额定短时耐受电流 Rated short time withstand current (4s) 额定电缆充电开断电流 Rated cable-charging breaking current 电机电压 motor voltage 分闸合闸装置电压 Rated supply voltage of closing and opening devices 执行标准 Relevant standarder 额定操作顺序 Rated operating sequence 重量 Weight 出厂日期 Manufacture date

Vacuum circuit breaker

kV A Hz kV kA kA A V

注意!

V

高压危险!请严格遵守操作规程。 Warning!

O-0.3s-CO-180s-CO

High voltage dangerous! Always observe

kg

the instruction manual and follow the rules.

上海通用电气开关有限公司 Shanghai GE Breakers Co.,Ltd.

SecoVac 3.3kV-17.5kV/T1250~4000A-40kA (Phase to phase distance: 275mm) 852 864 881

Withdrawable type 838

838

376.5

310 ±1 295 ±1

e

户内高压真空断路器

A Hz kV kA kA A V

Vacuum circuit breaker

注意!

V

高压危险!请严格遵守操作规程。 Warning!

O-0.3s-CO-180s-CO

kV A Hz kV kA kA A V

注意!

V

高压危险!请严格遵守操作规程。 Warning!

O-0.3s-CO-180s-CO

High voltage dangerous! Always observe

kg

86

kV

86

GE Consumer & Industrial Systems 产品型号 Type designation 出厂编号 Serial number 额定电压 Rated voltage(Ur) 额定电流 Rated normal current(Ir) 额定频率 Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) Rated lightning impulse withstand voltage(Up) 额定短路开断电流 Rated short-circuit breaking current(Isc) 额定短时耐受电流 Rated short time withstand current (4s) 额定电缆充电开断电流 Rated cable-charging breaking current 电机电压 motor voltage 分闸合闸装置电压 Rated supply voltage of closing and opening devices 执行标准 Relevant standarder 额定操作顺序 Rated operating sequence 重量 Weight 出厂日期 Manufacture date

户内高压真空断路器

Vacuum circuit breaker

735

735

310 ±1 295 ±1

e

GE Consumer & Industrial Systems 产品型号 Type designation 出厂编号 Serial number 额定电压 Rated voltage(Ur) 额定电流 Rated normal current(Ir) 额定频率 Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) Rated lightning impulse withstand voltage(Up) 额定短路开断电流 Rated short-circuit breaking current(Isc) 额定短时耐受电流 Rated short time withstand current (4s) 额定电缆充电开断电流 Rated cable-charging breaking current 电机电压 motor voltage 分闸合闸装置电压 Rated supply voltage of closing and opening devices 执行标准 Relevant standarder 额定操作顺序 Rated operating sequence 重量 Weight 出厂日期 Manufacture date

the instruction manual and follow the rules.

High voltage dangerous! Always observe

kg

上海通用电气开关有限公司

the instruction manual and follow the rules.

Shanghai GE Breakers Co.,Ltd.

上海通用电气开关有限公司

852 864 881

836±1 Fixed type (794) 275±1

586±1

836±1 (794)

275±1

76

76

Shanghai GE Breakers Co.,Ltd.

852 864 881

836±1 (794)

275±1

Ø109

Ø109

275±1

Selection Guide

376.5

95.5

95.5 361±1586±1

39

361±1

39

275±1

275±1

30 110

275

Terminal section

275

27

100

∅80 4-M10

451.5

310

(20mm in depth)

GE Engery

户内高压真空断路器

Vacuum circuit breaker

4-M12

kV A Hz kV

252

e

Industrial Solutions 产 品 型 号 Type designation 出 厂 编 号 Serial number 额 定 电 压 Rated voltage(Ur) 额 定 电 流 Rated normal current(Ir) 额 定 频 率 Rated frequency 额 定 雷 电 冲 击 耐 压 (峰值) Rated lightning impulse withstand voltage(Up) 额 定 短 路 开 断 电 流 Rated short-circuit breaking current(Isc) 额 定 短 时 耐 受 电 流 Rated short time withstand current (3s) 额 定 电 缆 充 电 开 断 电 流 Rated cable-charging breaking current 电 机 电 压 motor voltage 分 闸 合 闸 装 置 电 压 Rated supply voltage of closing and opening devices 执 行 标 准 Relevant standarder 额 定 操 作 顺 序 Rated operating sequence 重 量 Weight 出 厂 日 期 Manufacture date

kA kA A V V

注意!

2V&2V&2 2V&2V&2

高压危险!请严格遵守操作规程。 Warning!

kg

High voltage dangerous! Always observe the instruction manual and follow the rules.

上 海 通 用 电 气 开 关 有 限 公 司 Shanghai GE Breakers Co.,Ltd.

720 34.5

275

118

788

15

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Overall dimension SecoVac 3.3kV-17.5kV/T1250A/2000A-40kA (Phase to phase distance: 210mm) Withdrawable type

Fixed type 210

210

110 100

2XM10-Depth 15mm

45°

78

70

252

310

Selection Guide

M18 Depth 25mm

520 588

16

33.5 586

118

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

SecoVac 24kV-27kV/T630~1250A-31.5kA (Phase to phase distance: 210mm) Withdrawable type

Fixed type 210

210

Terminal section

70

302

665

Selection Guide

310

M18 depth 25mm

45,0°

52,0 520

4-M12

275

118

588

17

ø109

310±1

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

345±1

Overall dimension e

SecoVac 24kV-27kV/1250~2500A-31.5kA (Phase to phase distance: 275mm) Withdrawable type

881

ø109

838

ø109

838

852

112,5

64

74 74

112,5

64

345±1

e e

345±1

852 881

852

320 651±1 651±1

881

320

Fixed type 275±1,5 275±1,5

275±1,5 275±1,5

30 27

Terminal section 275

4-M10 depth 20mm

15 30

310

45

452

730

5

4-M12 720 788

18

ø82

145 100

305

Selection Guide

275

25

275

118

762

762

310±1

310±1

275±1,5

275±1,5

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

SecoVac VB2 Plus L-frame

B

A View 1250A spout

A

N

ØE

690

7

G

3150A Spout

453

∅1

M10 25mm depth M12 35mm depth H F F+9

65

9 16-∅

50

∅60

110

2

255

380 255

D±1

260

L

J

M10 23mm depth

C±1

270

M8 20mm depth

M R-∅

A View

31.5

SecoVac 3.3kV-17.5kV

200

200

216

I

59

P±1

P±1

59

1250A 25X84 3150A 42X126

725

B 794

C 275

D 453

E 49

F 632

G 1031

H 310

I 934

800mm 1250/2000A

915

781

310

468

90

782

1039

460

977

1000mm 3150A

915

779

310

468

109

982

1039

660

969

J 78 124/1250A 114/2000A 101

L 556

M 75

N 150

R 2

NA 584

P 150

NA

NA

NA

210

0

137.5

5

275

N 170 223

P 210 275

SecoVac 24kV-27kV A B

Selection Guide

A 914

650mm 1250A

25

C±1

73

N

m

0m

0X3

2500A Spout 60

G

M1

91 245.5

L

K

D±1

12

M J

E

E

120

197.5

mm

45

6X

M1

197.5 H F

I 896

P± 1 P± 1

800mm 1250A 1000mm 2500A

A 1142 1142

B 896 896

C 310 310

D 617.5 617.5

E 157.5 150

F 792 992

G 1121.5 1121.5

H 460 660

I 1142 1264

J 26 41

K 185 150

L 145 150

M 40 69.5

19

Measurement, Protection and Control

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

20

Measurement, Protection and Control Multilin 650 Family . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Multilin 3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Measurement, Protection and Control For more information visit our website: http://www.gedigitalenergy.com/multilin/catalog/F650.htm

Multilin 650 Family Advanced protection, control and monitoring system

Key benefits plus programmable logic ●● Flexible and cost effective control for complex systems -

Use IEC compatible programmable logic to customize the functionality of your protection & control system to address unique, site specific applications ●● Human machine interface (HMI) - Standard backlit LCD display

with 4 x 20, optional 16 x 40 (240 x 128 pixels) graphical LCD, programmable buttons and directional keys for selecting setting menus and submenus ●● Minimize replacement time - Modular with card draw-out

construction ●● Reduce troubleshooting time and maintenance costs - IRIG-B

●● Cost Effective Access information - Via multiple protocols,

through standard RS232 & RS485 Ethernet Ports ●● Optimal integration flexibility via open standard protocols -

Modbus RTU, DNP 3.0 Level 2, IEC 60870-5-104, IEC 61850, IEC 870-5-103 ●● Minimize communication down time - Reliable redundant

Ethernet Communication ports with 10/100BaseTX, 100BaseFX with ST connectors and optional double 100BaseFX, with ST connectors ●● Complete asset monitoring - Full metering including demand

& energy ●● Follow technology evolution - Flash memory for product field

upgrade

time synchronization, event reports, waveform capture, data logger

Measurement, Protection and Control

●● Unique built-in control features - Comprehensive protection

Applications ●● F650: Management and primary protection of distribution

feeders and bus couplers ●● F650: Backup protection of busses, transformers and power

lines ●● G650: Packaged generator mains failure detection

●● G650: Distributed generation management device ●● G650: Reliable Distributed Generation interconnection

protection system ●● W650: Wind turbine protection, control and monitoring ●● W650: Distributed generation grid interconnection device 21

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Features Protection and control

User interface

●● Up to 32 Programmable digital inputs

●● Large graphic (16 x 40) or regular (4 x 20) character display

●● Up to 16 digital outputs

●● Easy-to-use control via Shuttle key

●● Trip Circuit Supervision

●● Front USB port or standard RS232

●● Redundant power supply option

●● Rear wire 10/100BaseTX Ethernet for LAN connection

●● Configurable PLC logic according to IEC 61131-3

●● Rear wire CAN bus port (OPEN CAN protocol - W650)

●● Fully configurable graphic display HMI interface

●● Optional fibre optic 100BaseFX Ethernet, single or redundant

●● Alarms panel

●● Optional rear RS485 port ●● 1 ready LED and 15 programmable LED indicators

Monitoring and metering ●● Energy metering

●● Data logger

●● Demand metering

●● Sequence of event

●● Trip circuit monitoring

●● Self diagnostic

●● EnerVistaTM Integrator providing easy integration of data in the

650 relay into new or existing monitoring and control systems

●● Oscillography

Metering

Measurement, Protection and Control

Overview The Multilin 650 family has been designed

screens.

The Multilin 650 provides the following

as a comprehensive protection, control,

The metering capability allows 0.5%

metering values.

metering and monitoring package. The

accuracy for current and 1% from 10V to

●● Current: Ia, Ib, Ic, In, Ig, Isg

microprocessor based architecture

208V for voltage in metering range.

●● Phase-to-phase and phase-to-ground

is a complete solution for different

Monitoring functions include a 479

voltage values for bus and line: Van,

applications that complies with the most

event recorder, and a programmable

Vbn, Vcn, Vab, Vbc, Vca, Vx

relevant international standards.

oscillography recorder.

All the elements required for each

The Multilin 650’s communications

application have been integrated into a

capability and option make the product

single package for a cost-effective, reliable

very unique. These units include

and simple utilization. The low number of

a maximum of three independent

●● Power factor (per phase and total)

components, thanks to the use of state-

communication ports: COM1, COM2

●● Frequency

of-the-art but mature technology, deliver

and COM3, with many physical choices

●● These signals are available for local

a very high reliability.

through the use of two removable plug-

display and accessible remotely using

Hardware inputs and outputs have been

and-play boards.

communications

designed in a modular way that allow

The brain of the Multilin 650 units includes

easy migration from simple to more

a powerful built-in virtual PLC. This PLC

Recording functions

complex applications.

can be programmed according to the IEC

The recording functions within the Multilin

The control functions include a full-

61131-3 language by functional block

650 include:

scheme virtual PLC with an optional

diagrams.

●● Event recorder capable of storing 479

graphical display. The combination of

650 units come with 8 to 32 digital inputs

time-tagged events (1 true millisecond

both elements provide total control for

and with 8 to 16 outputs depending on

accurate tagging)

a bay. This means real-time monitoring

options. All digital inputs may be filtered

of breakers and selector switches, open

with a separate debounce time to tailor

can be stored in memory. The capacity

and close commands supervised by the

customer requirements.

of each record will depend on the type of

programmable interlockings and metering 22

●● Active power (per phase and total) : Wa,

Wb, Wc, W ●● Reactive power (per phase and total) :

VARa, VARb, VARc, VAR

●● Up to 20 separate oscillography records

oscillo selected (1 Mbyte/Max. No. Osc)

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

These records are stored in non volatile

Communications

memory. Therefore, there is no need

Multilin 650 units incorporate up to

for internal battery monitoring or

three ports that operate independently.

maintenance.

Redundant ports are available for high

TCP/IP and IEC 60870-5-104.

reliability applications: Trip circuit monitoring

Available protocols for rear port 1 and 2

Multilin 650 units offer as an option two

are ModBus RTU, IEC 103 and serial DNP

complete supervision circuits for breaker

3.0.

trip and closing coils and circuits. These

The third port is located in a removable

supervision inputs monitor both the

communications card. This plug-and-

battery voltage level and the continuity of

play card can be easily changed in the

the trip and/or closing circuits, applying

future as new standards arrive to the

current through those circuits and

market, thus providing a migration path

checking that it flows properly. In order

to the customer.

to apply this feature it is necessary to

The protocol available for the third port

choose I/O board 1 option 2.

is DNP 3.0 over TCP/IP, UDP/IP, ModBus

User Interface

●● Graphic 16 x 40 or text 4 x 20 LCD display ●● Fluorescent backlight to improve visibility

●● Local/Remote/Off pushbutton with LEDs ●● Key control for easy navigation ●● Ergonomic programmable keys

●● Electrically isolated front USB communication port ANSI Device Numbers & Functions

Functional Block Diagram

1

52 79 1

CLOSE Monitoring

27X

TRIP

3

3

50BF 1

49 3

50PH 50PL 3

3

46

48

3

3

32FP 3

32

32N

3

3

BROKEN CONDUCTOR

3

59X

51PH/V 51PL/V 67P R

R

3

3

3

50N 3

51N 3

3

67N 3

25 1

1

2

50G 3

1

2

51G

67G 3

3

50SG 51SG 3

3

27

59

50IG 3

67SG

METERING

3

3V_0

3

47 3

3

3

VTFF 1

81U 3

81O 3

81R 3

59NH 3

F650 Digital Bay Controller

59NL 3

EN F650 BLOCK F.CDR

Device Number

Function

N/A 81R VTFF

Bus/Line Overvoltage Neutral Overvoltage - High/Low Phase Directional Overcurrent Neutral Directional Overcurrent Ground Directional Overcurrent Sensitive Ground Directional Overcurrent Autorecloser Under/Over Frequency Broken Conductor Detection Load Encroachment Frequency Rate of Change VT Fuse Failure Detection

25 27/27X 32 32FP 32N 46 47 48 49 50 BF 50PH/PL 50N 50G 50SG 50IG 51N 51G 51SG 51PH/V 51PL/V 59/59X 59NH/NL 67P 67N 67G 67SG 79 81 U/O

Synchrocheck Bus/Line Undervoltage Sensitive Directional Power Forward Power Wattmetric zero-sequence directional Negative Sequence Time Overcurrent Negative Sequence Voltage Blocked Rotor Thermal Image - overload protection Breaker Failure Phase Instantaneous Overcurrent (High/Low) Neutral Instantaneous Overcurrent Ground Instantaneous Overcurrent Sensitive Ground Instantaneous Overcurrent Isolated Ground Instantaneous Overcurrent Neutral Time Overcurrent Ground Time Overcurrent Sensitive Ground Time Overcurrent Voltage Restraint Phase Time Overcurrent

Measurement, Protection and Control

●● Multicolor programmable LEDs with label panel

23

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Measurement, Protection and Control For more information visit our website: http://www.gedigitalenergy.com/multilin/catalog/3Series.htm

Multilin 3 Series Intuitive industrial and utility protective relay systems for feeders, motors and transformers

Key benefits ●● Easy-to-use and cost effective protection and control for

Measurement, Protection and Control

feeders, motors and transformers ●● Effortless draw-out construction eliminates requirements for

test switches and reduces downtime ●● Environmental monitoring system to alarm on destructive

operating conditions to enable preventative maintenance ●● Easy-to-use interface and set up in one simple step ●● Accelerated Life Cycle Tested to ensure reliability of relay

operation under abnormal conditions ●● Advanced power system diagnostics to increase reliability

through fault and disturbance recording capabilities ●● Arc Flash mitigation via zone inter-tripping, flex curves and

multiple setting groups

●● Application flexibility with the use of programmable logic

elements ●● Large backlit display with 40 characters for easy viewing of

relay information and settings ●● Flexible communications with multiple ports & protocols to

allow seamless integration into new and existing infrastructure ●● Easy access to information via multiple communication

network options including USB, Serial, Fiber & Copper Ethernet ●● Reduced wiring with support for remote I/O ●● Reduce setup and configuration time with the Simplified Motor

Setup screen ●● Powerful Security Audit Trail tool to increase security and

minimize system risks by tracking setting changes

Applications ●● Advanced protection, monitoring & control relays for feeders

(Multilin 350), motors (Multilin 339) and transformers (Multilin 345) ●● Industrial feeders with enhanced breaker monitoring and

diagnostics

24

●● Distribution utility down stream breaker protection ●● Medium voltage utility feeders with advanced control features

including, cold load pickup, auto reclose and multiple setting groups

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Features

Easy-to-use

Protection & control

Drawout construction

(for Multilin 350 Feeder Protection System)

The Multilin 3 Series offers a complete

●● Phase, neutral and ground TOC and IOC

drawout feature eliminating the need for

●● Undervoltage, overvoltage, frequency

rewiring after testing has been concluded.

●● Neutral/ground directional

The withdrawable feature also eradicates

●● Negative sequence overcurrent

the need to disconnect communication

●● ANSI, IAC, IEC, flex curves ●● Cable Thermal Model protection

Overview

cables, e.g. fiber, copper, RJ45, etc and helps retain communication status even

●● Breaker failure

The Multilin 3 Series of protection relays

after a relay has been withdrawn from its

●● Cold load pick-up

are highly functional, economical

case.

●● Four-shot auto reclose

protection relays for feeders, motors and

●● 8 digital inputs, 7 contact outputs

transformers. By providing an economical

●● Two setting groups

system for protection, control, monitoring and metering, and both local and

●● Event Recorder: 256 events with 1ms

time stamping ●● Oscillography with 32 samples per

cycle and digital states ●● IRIG-B clock synchronization ●● Relay & Asset Health Diagnostics ●● Security audit trail

User interface and programming

remote user interfaces in one assembly, the Multilin 3 Series relays effectively eliminate the need for expensive discrete components. The Multilin 3 Series provides detailed diagnostic information allowing users to troubleshoot and minimize downtime. Detailed diagnostics is provided via the 256 1ms time stamped event recorder

Advanced communications

and the 192 cycle Oscillography report

Easy integration into new or existing

sampled at 32 samples per cycle.

infrastructure

The robust Multilin 3 Series streamlines

With several Ethernet and serial port

user work flow processes and simplifies

options, and a variety of communication

engineering tasks such as configuration,

protocols, the Multilin 3 Series provides

wiring, testing, commissioning, and

advanced and flexible communication

maintenance. This cost-effective relay

selections enabling seamless integration

also offers enhanced features such as

into new or existing applications.

diagnostics, preventative maintenance,

The Multilin 3 Series supports various

EnerVista™ software

device health reports and advance

industry standard protocols such as, IEC

●● An industry-leading suite of software

security features.

61850 & IEC 61850 GOOSE, Modbus RTU,

●● 4x20 character LCD display ●● Control panel with 12 LED indicators ●● Front USB and rear serial, Ethernet and

Fiber ports ●● Multiple protocols - IEC 61850 & 61850

GOOSE, ModBus™ RTU, ModBus™ TCP/IP, DNP 3.0, IEC 60870-5-104, IEC 60870-5-103

tools that simplifies every aspect of

Modbus TCP/IP, DNP3.0, IEC 60870-5-104

working with Multilin devices

and IEC 60870-5-103.

Measurement, Protection and Control

Metering & monitoring

●● Document and software archiving

toolset to ensure reference material and device utilities are up-to-date

25

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Enhanced diagnostics

EnerVistaTM Launchpad

Security

Preventative maintenance

EnerVista™ Launchpad is a complete set of

Security audit trail

The Multilin 3 Series allows users to track

powerful device setup and configuration tools

The Multilin 3 Series monitors security

relay exposure to extreme environmental

that is included at no extra charge with the SR

and reliability of asset protection. The

conditions by monitoring and alarming

Relays.

Multilin 3 Series protection devices

at high temperatures. This data allows

●● Set up the Multilin 3 Series Relays - and any

offer complete traceability of any

user to proactively schedule regular

other Multilin device - in minutes. Retrieve

relay setting and command changes,

maintenance work and upgrade activities.

and view oscillography and event data at

allowing the user to quickly identify

the click of a button

changes made to the relay.

All relays utilize EnerVista setup TM

●● Build an instant archive on any of the

software for communication, monitoring and metering. Actual values, setpoints,

latest Multilin manuals, service advisories,

status, trending, and waveform capture

application notes, specifications or firmware for your SR Relay

information may all be viewed via

●● Automatic document and software version

the software, and can be used for

updates via the internet and detailed e-mail

troubleshooting.

notification of new releases

User Interface ●● SETPOINT GROUP 1, 2:

Measurement, Protection and Control

These indicators are continuously on if corresponding group provides settings for protection elements. TRIP: Indicator turns on when relay detects a trip condition. Operates the trip relay to open the breaker. ALARM: While relay detects an alarm condition, indicator flashes. PICKUP: Indicator lights steady when any protection feature pickup threshold exceeded.

●● DISPLAY:

4 line text for easy viewing of key data.

●● LEDs:

10 LED indicators for quick diagnostics.

●● KEYPAD:

Ten button keypad for access to device interrogation and change of settings.

●● FRONT PORT:

Electrically isolated front USB communication port.

Protection Features

ANSI Device Numbers & Functions

BUS BUS VT 52 79 TRIP 3

CLOSE

1

50N 2

51P 2

51N 1

CLP 1

50_2 1

50BF

49

1

1

59X

59_2 1

1

59N

81U

1

81O

2

2

METERING 1

79

50G/ 51G 51G

50G

TRANSIENT RECORDER EVENT RECORDER

1

350 RELAY

26

27X 1

MONITORING 50P

LOAD

59P

27P 1

2

Device Number 27P 27X 49 50P 50N 50G 50BF 50_2 51P 51G 51N 59P 59X 59N 59_2 67G 67N 79 81U 81O CLP

Function Phase Undervoltage Auxiliary Undervoltage Thermal Model Phase Instantaneous Overcurrent Neutral Instantaneous Overcurrent Ground/Sensitive Ground Instantaneous Overcurrent Breaker Failure Negative Sequence Overcurrent Phase Timed Overcurrent Ground Timed Overcurrent Neutral Timed Overcurrent Phase Overvoltage Auxiliary Overvoltage Neutral Overvoltage Negative Sequence Overvoltage Ground Directional Overcurrent Neutral Directional Overcurrent Autoreclose Underfrequency Overfrequency Cold Load Pickup

Latched Lockout available as a standard feature

Operation

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Operation Internal Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . 28 Working Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Vacuum interrupter . . . . . . . . . . . . . . . . . . . . . . . . 30 Working principle of operating mechanism . . . . 30 Spring motor spring charging . . . . . . . . . . . . . . 30 Closing operation . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Anti-Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Tripping operation . . . . . . . . . . . . . . . . . . . . . . . . . 31 Reclosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Interlocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Preparation Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

27

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Internal Wiring Diagram Withdrawable Type Spring Charge Motor 26

24

Closing Circuit

Breaker Interlock Circuit

10

25

V2

36

(22) S1

34

35

11

4

Operation

S9

14

21

43

22

S5 44

S9

34

13

33 34

S8

14

24

23 24

S8

13 S5

57

V5 A~ C+ B-

K0

(11)

(74)

S5

S5

(12)

91

31

41

71

61

63

23

33

83

93

92

32

42

72

62

64

24

34

84

94

S5

(2)

S8

53

43 44

S9

54

31

32

16 13 15 17 19 33 37 38

39 18

40

55

S9

S9

54

53 S8

54

S8

81 S5

21 22 51 50

82

12

S5

14

48

49 58

56

S9: Limit switch (service position)

CC: Closing coil

KO: Anti-pumping relay (optional)

S8: Limit switch (testing position)

TC: Trip coil

BC: Electromagnet for locking (optional)

S4: Electromagnet for locking's auxiliary switch

M: Spring Charge Motor

ZC: Electromagnet for locking truck (optional)

S5: Auxiliary switch

V1~V4: Rectifier

S1~S3: Energy storing limit switch Note: 1. This wiring diagram describes that a breaker is open, racked to test position with spring in discharge state. 2. The polarity in dashed frame should be connected to common DC voltage terminal. 3. Rectifier will be removed if DC supply voltage is being used.

28

D~

2

53

23

33

13 14

47

1

V3

(73)

(54) S5

20

2

8

29

ZC

43 44

S3

9 23 27 28

BC

(21)

(14)

7

Y4 1

(53) S5

(3)

S3

5

TC

S4

(5)

(22)

3

S2

M (51) (52)

Truck Interlock Circuit 6

CC

K0 (13) (14)

(13)

30

V4

V1

(21)

Opening Circuit

52

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Fixed Type Spring Charge Motor

Breaker Interlock Circuit Opening Circuit 30

52

10

25

24

26

Closing Circuit

V2

M

S4

S5

(73)

(54) S5

(74)

(3)

(14)

36

35

2

43 S5 44 S5

21 22

(12)

S5

91

31

41

71

61

63

23

33

83

93

92

32

42

72

62

64

24

34

84

94

S5

(22) S1

11

22

(11) S5

(2) K0

(21) S3

34

21

8

51

31

32

16 13 15 17 19 33 37 38

39 18

4

13

81

14 S5

82

12

50

20

Operation

(13)

9 23 27 28 29

BC

(53)

(5)

(22) S3

7

TC

(13) (14) S2

(21)

5

CC

K0

(51) (52)

3

V3

V4

V1

6

S5

14

S4: Electromagnet for locking's auxiliary switch

CC: Closing coil

KO: Anti-pumping relay (optional)

S5: Auxiliary switch

TC: Trip coil

BC: Over current release coil (optional)

S1~S3: Energy storing travel switch

M: Energy storing motor

ZC: Electromagnet for locking (optional)

V1~V4: Rectifier

C: Control

Note: 1. This wiring diagram describes that a breaker is uncharged and is in an open state. 2. The polarity in dashed frame should be consistent when the operation voltage is DC.

29

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Working Principle Vacuum interrupter The vacuum gas pressure inside vacuum interrupter is less than 1.33×10-3Pa. Under normal circuit conditions the interrupter is closed. Arcing is established within the interrupter by withdrawing the moving contact from stationary contact. This arc burns in the metal vapor evaporated from local hot spots on the contact surfaces. The metal vapor continually leaves the inter-contact region and recondenses on the contact surfaces and surrounding metal vapor condensation shield. The latter is usually isolated from both contacts and serves to protect the glass or ceramic envelope from vapor deposition. At current zero, vapor production ceases and the original vacuum condition is rapidly approached. The dielectric strength of the interrupter also increases, and the circuit is interrupted. Within the contacts in the open position, the circuit voltage is withstood internally by the inter-contact gap

Operation

and externally by the insulating envelope.

Working Principle of Operating Mechanism Spring motor spring charging 1

The energy that is necessary for closing the circuit breaker is provided by the closing spring. The energy storage can be done by the motor or by the manual charging handle. Motor spring charging The energy charging mechanism consists of energy storing motor, gear wheel, cam, holder and closing spring. When the energy-storing motor (11) is charged, the pinion of output shaft (12) that is connected to motor will rotateand drive the gear wheel. The holder fixed on the gear wheel will make the cam fixed on the shaft move, which then drive the shaft to rotate, so that draws out the closing spring (17) for storing energy. When the block on the gear wheel is pushed away, the clutch is separated and the holder (4) will hold the roller on the cam (5) to keep the mechanism in charged position, thus completing the charging operation succeeds.

30

6 2

5 4 3 Figure 3. 1 Embedded pole 2 Insulating rod 3 Opening spring

4 Holder 5 Cam 6 Position switch

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

When energy is charged manually, the operator charges the spring by operating the energy-charging handle on the mechanism up and down repeatedly. When the charging operation is completed, you can hear a 'click', and the energy charging indicator (13) is switched over, as well as the status of position switch (6), cutting the secondary charging circuit. The operating mechanism now is ready for the next operation. (Figure 3)

Closing operation

Anti-Pump

When the closing circuit is powered, the closing coil is energized

Anti-pumping function is fitted with SecoVac to prevent repeated

and the holder (4) will rotate counter clockwise to break away

sequences of opening and closing operations. Once the circuit

from the roller on the cam (5). The cam, under the action of the

breaker is in closed position, the closing operation will be

force from closing spring (17), will rotate clockwise,

prohibited.

to push the roller on the main shaft, which will move the main connecting rod down through arm, so that the insulating rod (2) moves upright, pushing the movable contact to the fixed contact at the required speed, and compressing the contact spring and making it a necessary contact travel (overtravel) to ensure the pressure is generated between movable and fixed contacts.

Reclosing When the circuit breaker is closed, the mechanism can be charged for close, so that the circuit breaker can reclose immediately after tripping.

After the closed operation is finished, the closed/opening indicator (9) will indicate 'closed'. The power to the closing circuit will be cut. If the external power supply is energized, the charging

7

Operation

shaft (10) in counter clockwise rotation. The main shaft moves the

circuit motor will operate and the charging operation will be finished automatically. Note: Once the circuit breaker is in closed position, the closing operation will be prohibited.

Tripping operation When the breaker receives an opening command (the opening push button is pressed or the tripping coil (16) is energized), the tripping shaft will rotate clockwise. Under the action of opening spring (3) and contact-compressing spring, main shaft will move clockwise, and the insulating rod (2) will make the movable contact to separate from the fixed contact at a suitable speed. The buffer will absorb the residual energy and tripping operation is completed. After the tripping operation is finished, the closing/opening indicator (9) will indicate 'open'. Meanwhile, the counter will record the operation.

17

8

16

9 10

15

11

14 13 12 Figure 4. 7 Closing coil 8 Holder 9 Open/close indicator 10 Main shaft 11 Motor 12 Output shaft

13 Charging indicator 14 Latch coil 15 Over-current release 16 Tripping coil 17 Closing spring

31

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Interlocks

Installation

The follow interlocking facilities are

Correct installation is of primary

incorporated to ensure the safe operation

importance, the manufacturer’s

of the breaker. when the breaker is closed,

instructions must be carefully studied

the withdrawable circuit breaker cannot

and followed. It is good practice to use

be racked between the service position

gloves for handling the breaker during the

and test position.

installation.

●● When the earthing switch is in the

closed position, the withdrawable

Please carry out installation and wiring

circuit breaker cannot be racked into

of breaker according to manual. Do not

the service position

place any foreign objects in the breaker or

●● When the withdrawable circuit breaker

●● The careful and professional

modify it in anyway.

is in service position, the earthing

installation is a fundamental condition

switch cannot be closed

for the failure free operation of the

Check before installation

circuit breaker ●● The circuit breaker should be

After the breaker is unpacked, check

installed so that there are no external

the poles for any signs of mechanical

forces applied to it from busbars or

damage. The product nameplate and

mechanical supports

quality certificate shall conform to the

Operation

Installation for fixed circuit breakers

●● The busbar connection should not

order. Check goods according with the

cause any deformation to the breaker

packing list.

terminals ●● Take note of supplied drawings for bolt

Clean the insulating parts with a clean dry cloth. Make sure the upper and lower

sizing and lengths ●● Use the standard bolts with strength

contact arms are clean and free of any

of class 8.8 and the disc springs to

deformation caused by mishandling

tighten the bus bar (Table 1)

during transport or storage. Check the vacuum degree in the vacuum interrupter through power frequency withstand voltage test. If it fails, please contact or your local GE office.

Table 1 Tightening torque of bolt Basic dimensions of bolts (mm) M8 M10 M12 M16

32

Tightening torque without lubricant applied (N•m) 25 45 85 170

Tightening torgue with lubricant applied (N•m) 10 25 45 80

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Commissioning

Preparation Work

All commissioning and operation work

●● Check the circuit breaker for any

shall be carried out by persons who have

damage or any other dangerous

received professional training and are

environmental influence

familiar with operation of the breaker.

●● Wipe down the breaker, especially dirt

Necessary protective and preventive

that may have accumulated on the

measures shall be taken during work.

surface of the insulator. Especially the

●● Use the product under normal working

dirt on the surface of insulation

conditions and within the range of technical data according to the specifications of IEC 62271-1:2007

●● The lifting hook of the circuit breaker

must be removed prior to operation ●● Check the primary and secondary

circuits as well as the earthing ●● Implement energy charged, opening

and closing operations. Manually

Considerations

ensure the breaker is operating correctly

Operation for withdrawable circuit breaker ●● Put the circuit breaker into test position ●● Connect the secondary wiring plug and

times to ensure correct operation by local and remote control ●● Insert the handle and rotate the racking

handle clockwise about 20 revolutions.

Operation

open and close the breaker several

Upon the 'click', the withdrawable circuit breaker will be in the service position (Don't apply excessive force, to avoid any damage)

33

Check List

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Check List

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

34

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Check list for SecoVac 3.3kV-17.5kV IEC SecoVac VB2 Plus Check list COUNTRY:

PROJECT NAME:

PO NO.:

BASIC Type Code:

Qty:

Type

□ Withdrawable

□ Fixed

Rated Voltage

□ 12kV

□ 17.5kV

Rated Current

□ 630A

□ 1250A

□ 1600A

Rated Short-Circuit Breaking Current

□ 25kA

□ 31.5kA

□ 40kA

Pole Center Distance (P)

□ 150mm 630A, 1250A; 25kA, 31.5kA

□ 275mm 1600A, 2000A, 3150A, 4000A; 25kA, 31.5kA, 40kA

□ DC24V

□ DC30V

□ DC36V

□ DC48V

□ DC60V

Tripping/Closing Release (Y2, Y3)

□ 2000A

□ 2500A

□ 3150A

□ DC110V

□ DC125V

□ DC220V

□ AC110V

□ AC220V

□ Other

Charging Motor (M)

□ DC110V

□ DC125V

□ DC220V

□ AC110V

□ AC220V

□ Other

Secondary Wiring

□ Standard

Withdrawable Type SecoVac

Earthing

□ Earthing at the bottom of SecoVac VB2 Plus withdrawable unit □ Earthing on both sides of SecoVac VB2 Plus withdrawable unit □ Other

Fixed Type SecoVac

Mechanical □ Mechanical Interlock (VCB-DS & VCB-ES) Interlock Earthing

Ground Type

□ Nonstandard (Refer to drawing with number:

□ Earthing at the bottom of SecoVac withdrawable unit

Dimension □ Standard

□ 4000A

)

□ Other

□ Nonstandard (Refer to drawing with number:

)

OPTION 1: Blocking magnet of closing circuit loop (Y1)

□ DC220V

□ DC110V

Anti-Pump Relay (K0)

□ Required

□ Not required

□ AC220V

□ AC110V

□ Other

□ Not required

OPTION 2: (Extra expense is required.) Secondary Tripping Release (Y10) Blocking Magnet of SecoVac withdrawable unit (Y0)

□ DC24V

□ DC30V

□ DC36V

□ DC48V

□ DC60V

□ DC110V

□ DC125V

□ DC220V

□ AC110V

□ AC220V

□ DC220V

□ DC110V

□ AC220V

□ AC110V

□ Other

□ Other

Other Special Requirement (Please list other special requirement if any, and attach drawings or attachment)

By:

□ Required (Extra price needed)

(Signature & Stamp)

Remark: 1 Please tick √ in □ and send this checking list with official purchase order.

Check List

□ Not required

L-Frame

2 One secondary socket with jacks is offered for each SecoVac. One operation lever and one charging lever is offered for each five SecoVac of each project. Additional quantity required beyond above will be charged. 3 'Standard' herein means the solutions listed in SecoVac brochure. Should you have any question, please feel free to contact us. 4 If Option 1 or 2 is not ticked, SecoVac will not be equipped with related function. If Option 2 or other nonstandard solution is required, it will be charged additionally, and the delivery time will be longer. 35

SecoVac 3.3kV-27kV Embedded Pole Vacuum Circuit Breaker

Check list for SecoVac 24kV, 27kV IEC SecoVac VB2 Plus Check list COUNTRY:

PROJECT NAME:

PO NO.:

BASIC Type Code:

Qty:

Type

□ Withdrawable

□ Fixed

Rated Voltage

□ 24kV

□ 27kV

Rated Current

□ 1250A

□ 1600A

Rated Short-Circuit Breaking Current

□ 31.5kA

□ 25kA

Pole Center Distance (P)

□ 210mm 630A, 1250A; 25kA, 31.5kA

□ 275mm 2000A, 2500A; 25kA, 31.5kA

□ DC24V

□ DC36V

Tripping/Closing Release (Y2, Y3)

□ DC30V

□ 2000A

□ 2500A

□ DC48V

□ DC60V

□ DC110V

□ DC125V

□ DC220V

□ AC110V

□ AC220V

□ Other

Charging Motor (M)

□ DC110V

□ DC125V

□ DC220V

□ AC110V

□ AC220V

□ Other

Secondary Wiring

□ Standard

Withdrawable Type SecoVac

Earthing

□ Earthing at the bottom of SecoVac VB2 Plus withdrawable unit □ Earthing on both sides of SecoVac VB2 Plus withdrawable unit □ Other

Fixed Type SecoVac

Mechanical □ Mechanical Interlock (VCB-DS & VCB-ES) Interlock Earthing

Ground Type

□ Nonstandard (Refer to drawing with number:

□ Earthing at the bottom of SecoVac withdrawable unit

Dimension □ Standard

)

□ Other

□ Nonstandard (Refer to drawing with number:

)

OPTION 1: Blocking magnet of closing circuit loop (Y1)

□ DC220V

□ DC110V

Anti-Pump Relay (K0)

□ Required

□ Not required

□ AC220V

□ AC110V

□ Other

□ Not required

OPTION 2: (Extra expense is required.) Secondary Tripping Release (Y10) Blocking Magnet of SecoVac withdrawable unit (Y0)

□ DC24V

□ DC30V

□ DC36V

□ DC48V

□ DC60V

□ DC110V

□ DC125V

□ DC220V

□ AC110V

□ AC220V

□ DC220V

□ DC110V

□ AC220V

□ AC110V

□ Other

□ Other

Other Special Requirement (Please list other special requirement if any, and attach drawings or attachment) □ Not required

Check List

L-Frame

By:

□ Required (Extra price needed)

(Signature & Stamp)

Remark: 1 Please tick √ in □ and send this checking list with official purchase order. 2 One secondary socket with jacks is offered for each SecoVac. One operation lever and one charging lever is offered for each five SecoVac of each project. Additional quantity required beyond above will be charged. 3 'Standard' herein means the solutions listed in SecoVac brochure. Should you have any question, please feel free to contact us. 4 If Option 1 or 2 is not ticked, SecoVac will not be equipped with related function. If Option 2 or other nonstandard solution is required, it will be charged additionally, and the delivery time will be longer.

36

You may be interested in other MV Seco-family products For more information, please visit www.geindustrial.com

GE Energy

Greater China Shanghai

Taiwan

4F, Building 2, CTP, No.1 Hua Tuo Rd.

6F, No. 8, Min Sheng E. Rd., Sec. 3,

Zhang Jiang Hi-Tech Park

Taipei 10480

Shanghai, China 201203

T : +886 2 2183 7000

T : +86 21 3877 7888

F : +886 2 2516 6829

F : +86 21 3877 7600

South East Aisa Malaysia

Philippines

Indonesia

Level 6, 1 Sentral,

8F Net Cube Building, 30th Street

BRI II Tower, 27th floor

Jalan Travers, Kuala Lumpur Sentral

Corner 3rd Avenue, Crescent West Park

Jl. Jend. Sudirman No. 44-46

Kuala Lumpur, Malaysia 50470

Global City Taguig 1634

Jakarta 10210

T : +603 2273 9788

T : +63 2 877 7000

T: +62 21 573 0430

F : +603 2273 7988

F : +63 2 846 0629

F: +62 21 574 7089

Thailand

Vietnam

Singapore

25th floor, CRC Tower, All Seasons Place

Saigon Centre, Unit 1, Floor 7

240 Tanjong Pagar Road

87/2 Wireless Road, Lumpini

Le Loi Boulevard, District 1

#06-00 GE Tower

Pathumwan, Bangkok 10330

HoChiMinh City

Singapore 088540

T : +66 2 648 0202

T : +84 8 3914 6700

T : +65 6220 7022

F : +66 2 648 0200

F : +84 8 3827 8229

F : +65 6326 3015

ANZ

Australia

New Zealand

125-127 Long Street

Level 1, 8 Tangihua Street

Smithfield, Sydney, NSW 2164

Auckland, North Island

T : +61 2 8788 6911

T : +64 9 353 6706

F : +61 2 8788 7224

F : +64 9 353 6707

North Asia Japan

Korea

11F, Akasaka Park Bldg.,5-2-20

3rd Floor, GE Tower, 71-3,

Akasaka, Minato-ku

Cheongdam-dong, Gangnam-gu

Tokyo 107-6111

Seoul, Korea 135-100

T : +81 3 3588 5288

T : +82 2 6201 4501

F : +81 3 3585 3010

F : +82 2 6201 4344

For more information, please visit www.geindustrial.com Printing Code: IN201202B30EN © Copyright GE Industrial Solutions 2012