LV Series High-Efficiency Slim-Duct & Wall-Mounted Ductless systems Up to 24.5 SEER / 12.5 HSPF
Product Features • Inverter Compressor • 208/230/1 Power Supply • Cooling Operating Range 0° 115° F (With Wind Baffle) • Heating Operating Range 0° 77° F (w/ Drain Pan Heater) • Precharged for up to 33 ft of Liquid Line • Indoor Sound Pressure as Low as 22 dB(A) • Outdoor Sound Pressures as Low as 48 dB(A) • Program Dry Function • Powerful Operation • Intelligent Eye† Occupancy Sensor
• • • • • • • • • • •
Backlit LCD Wireless Remote Controller 3-D Airflow † Weekly Timer † Outdoor Unit Quiet Operation Auto Changeover Auto Fan Speed Control Self-Diagnostics with Digital Display Auto-Restart after Power Failure Anti-Corrosion Treatment on Heat Exchanger Max Piping (09/12 MBH): 66' Length, 49' Height Max Piping (15/18/24 MBH): 98' Length, 66' Height † On wall-mounted units only
ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency. ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Products that earn the ENERGY STAR prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This product meets ENERGY STAR requirements when appropriate coil components are used. Ask your contractor for details.
SS-DLV
* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration and some of the additional requirements are not required in California or Quebec.
www.daikincomfort.com
5/16 Supersedes 3/16
Nomenclature
FT 1,2
X 3
S 4
18 5,6
L 7
VJ 8,9
U 10
Indoor Type CD Slim Duct* CT Wall Mount* F Indoor Unit FD Slim Duct FT Wall Mount FV Floor-‐Standing
Standard Compatibility U -‐-‐ United States Power Supply VJ -‐-‐ Single Phase 208/230V
Series L -‐-‐ Major Design Category
System Type F 2' x 2' Ceiling Cassette X R-‐410A Cooling/ Heating Efficiency Level G Highest Q N Standard S
Capacity 18 -‐-‐ 18,000 BTU/h 24 -‐-‐ 24,000 BTU/h
09 -‐-‐ 9.000 BTU/h 12 -‐-‐ 12:000 BTU/h 15 -‐-‐ 15,000 BTU/h
R-‐410A Heat Pump High
* Compatible with multi-‐split MXS outdoor units only
R 1
X 2
S 3
09 4,5
L 6
VJ 7,8
U 9
Unit Type R Air-‐Cooled Single Split Outdoor Unit
Standard Compatibility U -‐-‐ United States Power Supply VJ -‐-‐ Single Phase 208/230V
System Type X R-‐410A, Heat Pump K R-‐410A, Cooling Only Efficiency Level N Standard _ Mid (Blank) S High G Highest
2
Series L -‐-‐ Major Design Category
09 -‐-‐ 9.000 BTU/h 12 -‐-‐ 12:000 BTU/h 15 -‐-‐ 15,000 BTU/h
www.daikincomfort.com
Capacity 18 -‐-‐ 18,000 BTU/h 24 -‐-‐ 24,000 BTU/h
SS-DLV
Product Specifications — Wall-Mounted Units
LV Series High-Efficiency System Performance
Nominal Capacities
0.75 Ton
1.0 Ton
1.25 Ton
1.5 Ton
2.0 Ton
9,000 4,400–10,600 12,000 4,400–15,600 24.5 4.5 15.3 12.5
12,000 4,800–13,800 14,400 4,800–18,000 23 4.4 12.8 12.5
15,000 5,800–18,000 18,000 5,800–22,300 20.6 4 14.4 11.6
18,000 5,800–21,600 21,600 5,800–26,700 20.3 3.7 12.7 11
21,500 7,800–25,800 25,400 7,800–31,400 20 3.4 12.5 10.6
Power Supply V/Ph/Hz Minimum Circuit Amps A Maximum Overcurrent Protection A Power Consumption - Cooling W Power Consumption - Heating W Indoor Units: FTXS_LVJU Wall-Mounted Units
208-230/1/60 8 15 590 790
208-230/1/60 8.8 15 940 970
208-230/1/60 13.8 20 1,040 1,320
208-230/1/60 13.8 20 1,420 1,710
208-230/1/60 17.5 20 1,720 2,210
Model Name
Cooling Capacity (Rated) Cooling Capacity (Min–Max) Heating Capacity (Rated) Heating Capacity (Min–Max) SEER COP EER HSPF
BTU/h BTU/h BTU/h BTU/h
Electrical Data
Moisture Removal Airflow-Wet (H/M/L/SL) Airflow-Dry (H/M/L/SL) Sound Pressure - Cooling (H/M/L/SL) Sound Pressure - Heating (H/M/L/SL) Liquid (O.D.) Piping Gas (O.D.) Connections Condensate Drain Dimensions (H x W x D) Net Weight Outdoor Units: RXS_LVJU Heat Pump
FTXS09LVJU
FTXS12LVJU
FTXS15LVJU
FTXS18LVJU
FTXS24LVJU
gal/h CFM CFM dB(A) dB(A)
0.3 381/279/194/145 420/321/233/219 41/33/25/22 42/35/28/25
0.5 403/307/205/155 438/335/240/212 45/37/29/23 45/39/29/26
0.8 568/477/385/360 593/505/417/371 45/40/35/32 43/38/33/30
1 58¾84/385/360 625/526/431/399 46/41/36/33 45/40/35/32
1.2 64¾94/350/328 699/572/445/403 51/42/37/34 48/42/37/34
in. in. in.
Ø 1/4 Ø⅜ Ø 5/8
Ø 1/4 Ø⅜ Ø 5/8
Ø 1/4 Ø 1/2 Ø 5/8
Ø 1/4 Ø 1/2 Ø 5/8
Ø 1/4 Ø 5/8 Ø 5/8
in. lbs.
20
22
31
13⅜ X 41⁵/₁₆ X 9¾ 31
31
RXS09LVJU
RXS12LVJU
RXS15LVJU
RXS18LVJU
RXS24LVJU
Model Name Sound Pressure Level - Cooling Sound Pressure Level - Heating Operating Range - Cooling Operating Range - Cooling ¹ Operating Range - Heating Max. Piping Length Max. Piping Height Dimensions (H x W x D) Net Weight
dB(A) dB(A) °F DB °F DB °F DB ft. ft. in. lbs.
11⅝ X 31½ X 8⁷/₁₆
47/43 49/44 48/44 49/45 14° – 115° 14° – 115° 0° – 115° 0° – 115° 5° – 77° 5° – 77° 65.6 65.6 49.2 49.2 21⅝ X 30⅛ x 11¼ 75 75
47/44 49/46 48/45 49/46 14° – 115° 14° – 115° 0° – 115° 0° – 115° 5° – 77° 5° – 77° 98.4 98.4 65.6 65.6 28¹⁵/₁₆ X 32½ X 11¹³/₁₆ 104 104
52/49 52/49 14° – 115° 0° – 115° 5° – 77° 98.4 65.6 30⁵/₁₆ X 35⁷/₁₆ X 12⅝ 159
¹ with Optional Wind Baffle ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency. ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Products that are recognized as the Most Efficient of ENERGY STAR in 2016 prevent greenhouse gas emissions by meeting rigorous energy efficiency performance levels set by the U.S. Environmental Protection Agency. This product meets ENERGY STAR requirements when appropriate coil components are used. Ask your contractor for details.
SS-DLV
www.daikincomfort.com
3
Product Specifications — Slim-Duct Units
LV Series Standard-Efficiency System Performance Nominal Capacities 0.75 Ton 1.0 Ton Cooling Capacity (Rated) BTU/h 8,500 11,500 Cooling Capacity (Min–Max) BTU/h 4,400 - 8,500 4,800 - 11,500 Heating Capacity (Rated) BTU/h 10,000 11,500 Heating Capacity (Min–Max) BTU/h 4,400 - 10,000 4,800 - 11,500 SEER 15.1 15.5 COP 3.5 3.5 EER 11.2 9.1 HSPF 10.3 10.4 Electrical Data Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 A 8 8.8 Minimum Circuit Amps 15 15 Maximum Overcurrent Protection A W 760 1,260 Power Consumption - Cooling 850 960 Power Consumption - Heating W Indoor Units: FDXS_LVJU Slim Duct Built-in Units Model Name FDXS09LVJU FDXS12LVJU External Static Pressure in. W.G. 0.1 0.1 Moisture Removal gal/h 2.5 4 Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 Sound Pressure Level - Cooling (H/M/L) dB(A) 35/33/31 35/33/31 Sound Pressure Level - Heating (H/M/L) dB(A) 35/33/31 35/33/31 Liquid (O.D.) in. Ø 1/4 Ø 1/4 Piping Gas (O.D.) in. Ø⅜ Ø⅜ Connections Condensate Drain in. Ø 25/32 Ø 25/32 Dimensions (H x W x D) Inch 7⅞ X 27⁹/₁₆ X 24⁷/₁₆ Net Weight lbs. 47 47 Outdoor Units: RXS_LVJU Heat Pump Model Name RXS09LVJU RXS12LVJU Sound Pressure Level - Cooling (H/L) dB(A) 47/43 49/44 Sound Pressure Level - Heating (H/L) dB(A) 48/44 49/45 Operating Range - Cooling °F DB 14° – 115° 14° – 115° Operating Range - Cooling ¹ °F DB 0° – 115° 0° – 115° Operating Range - Heating °F DB 5° – 77° 5° – 77° Max. Piping Length ft. 65.6 65.6 Max. Piping Height ft. 49.2 49.2 Dimensions (H x W x D) in. 21⅝ X 30⅛ x 11¼ Net Weight lbs. 75 75 ¹ with Optional Wind Baffle
4
www.daikincomfort.com
SS-DLV
Dimensions — Indoor Units FTXS09/12LVJU THE MARK (→) SHOWS PIPING DIRECTION 31-1/2 (800mm) REAR LEFT
1-3/16 (30mm) MIN (SPACE FOR PERFORMANCE)
AIRFLOW (INDOOR)
( INCLUDING MOUNTING PLATE )
RIGHT
8-9/16 (217mm) 1-15/16 (50mm) MIN
8-7/16 (215mm)
(SPACE FOR MAINTENANCE)
NAME PLATE
11-5/8 (295mm)
FRONT GRILLE FIXED SCREWS (INSIDE)
TERMINAL BLOCK WITH GROUND TERMINAL
INTELLIGENT EYE SENSOR
SIGNAL RECEIVER
OPERATION LAMP TIMER LAMP
9/16 (14.5mm)
INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) MODEL NAME PLATE
SIGNAL TRANSMITTER UP/DOWN (AUTOMATIC)
BLADE ANGLES
7-3/8 (187mm)
COOLING, DRY
FAN
HEATING 5°
15°
30°
35°
30°
55°
45°
70°
30°
65°
80°
45
°
(ARC452A21)
23-1/16 (586mm) 5-3/4 (145.5mm)
65°
RIGHT/LEFT (AUTOMATIC)
WIRELESS REMOTE CONTROLLER
DRAIN HOSE (CONNECTING PART O.D. φ5/8 (φ16mm) THE HOSE LENGTH OF OUTSIDE THE UNIT IS APPROX. 18-5/16 (465mm)) 31-1/2 (800mm)
1-3/4 (44.5mm)
2-5/16 (58mm) 11/16 (18mm)
GAS PIPE φ3/8 (φ9.5mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 13-3/4 (350mm)) LIQUID PIPE φ1/4 (φ6.4mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15-3/4 (400mm))
1-3/4 (44.5mm)
LOUVERS
1-15/16 (50mm) MIN (SPACE FOR MAINTENANCE)
2-3/8 (60mm)
WALL HOLE φ2-9/16 (φ65mm) HOLE 2-5/16 (59.5mm)
WALL HOLE FOR EMBEDDED PIPING φ2-9/16 (φ65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
°
45
11-5/8 (295mm)
BOTTOM
REQUIRED SPACE
C: 3D074094A
FTXS15/18LVJU RIGHT
INCLUDING (INSTALLATION PLATE )
13-3/8 (340mm)
9-13/16 (250mm) 9-3/4 (248mm)
NAME PLATE
FRONT GRILLE FIXING SCREWS (INSIDE) BOTTOM
TERMINAL BLOCK WITH GROUND TERMINAL (INSIDE)
INTELLIGENT EYE SENSOR SIGNAL RECEIVER
7-3/8 (187mm)
COOLING, DRY 15°
15° 50°
25°
30°
40°
60°
70°
RIGHT/LEFT (AUTOMATIC)
WIRELESS REMOTE CONTROLLER (ARC452A21)
FAN
HEATING
45
°
75°
25° 70°
41-5/16 (1050mm) 37-5/16 (947mm)
75°
°
45
www.daikincomfort.com
1-3/8 (35.5mm)
WALL HOLE FOR EMBEDDED WALL HOLE PIPING φ3-1/8 (φ80mm) HOLE φ3-1/8 (φ80mm) HOLE 2-9/16 (65mm) 3-1/2 (89mm)
STANDARD LOCATIONS OF WALL HOLES
5/8 (16mm)
UP/DOWN (AUTOMATIC)
8-1/4 (210mm)
BLADE ANGLES
2-5/16 (58mm) 11/16 (18mm)
DRAIN HOSE (CONNECTING PART O.D. φ5/8 (φ16mm) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 18-5/16 (465mm))
1-3/4 (45mm)
SIGNAL TRANSMITTER
GAS PIPE φ1/2 (φ12.7mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15-3/4 (400mm)) LIQUID PIPE φ1/4 (φ6.4mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18-1/8 (460mm)) 9/16 (14.5mm)
OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) MODEL NAME PLATE
1-3/4 (45mm)
LOUVERS
SS-DLV
MIN.1-15/16 (50mm) MIN.1-15/16 (50mm) (SPACE FOR (SPACE FOR MAINTENANCE) REQUIRED SPACE MAINTENANCE)
13-3/8 (340mm)
LEFT
41-5/16 (1050mm)
MIN.1-3/16 (30mm) (SPACE FOR PERFORMANCE)
AIRFLOW (INDOOR)
THE MARK ( → )SHOWS PIPING DIRECTION REAR
C: 3D074024A
5
Dimensions — Indoor Units FTXS24LVJU THE MARK ( → ) SHOWS PIPING DIRECTION LEFT
AIRFLOW (INDOOR)
41-5/16 (1050mm)
MIN.1-3/16 (30mm) (SPACE FOR PERFORMANCE)
REAR
RIGHT INCLUDING (INSTALLATION PLATE ) 9-13/16 (250mm)
13-3/8 (340mm)
9-3/4 (248mm)
FRONT GRILLE FIXING SCREWS (INSIDE)
Min. 1-15/16 (50mm)) Min. 1-15/16 (50mm) (SPACE FOR (SPACE FOR REQUIRED SPACE MAINTENANCE) MAINTENANCE)
NAME PLATE TERMINAL BLOCK WITH GROUND TERMINAL (INSIDE)
INTELLIGENT EYE SENSOR
7-3/8 (187mm)
COOLING, DRY
15°
15° 30°
50°
40°
60°
70°
37-5/16 (947mm)
1-3/8 (35.5mm)
FAN
HEATING
25°
41-5/16 (1050mm)
25° 75°
75°
70°
WALL HOLE FOR EMBEDDED PIPING φ3-1/8 (φ80mm) HOLE 2-9/16 (65mm)
RIGHT/LEFT (AUTOMATIC)
WALL HOLE φ3-1/8 (φ80mm) HOLE 3-1/2 (89mm)
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER 45
(ARC452A21)
45
°
°
5/8 (16mm)
BLADE ANGLES UP/DOWN (AUTOMATIC)
13-3/8 (340mm)
MODEL NAME PLATE
1-3/4 (45mm)
2-5/16 (58mm) 11/16 (18mm)
DRAIN HOSE (CONNECTING PART O.D. φ5/8 (φ16mm) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 18-5/16 (465mm))
GAS PIPE φ 5/8 (φ15.9mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15-3/4 (400mm)) LIQUID PIPE φ1/4 (φ6.4mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18-1/8 (460mm)) 9/16 (14.5mm)
SIGNAL TRANSMITTER
OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE)
8-1/4 (210mm)
SIGNAL RECEIVER
LOUVERS
1-3/4 (45mm)
BOTTOM
C: 3D073962A
1
23-5/8 (600mm) 22-13/16 (580mm) 10
7-3/8 (187mm) 13/16 (20mm)
3-15/16 (100mm)
INFRARED RECEIVER UNIT WIRELESS REMOTE CONTROLLER (ARC452A23)
3/8 (10mm)
ARROW VIEW INSPECTION DOOR (CEILING OPENING) 16-M5 HOLES (ALL AROUND) 3-9/16 (90mm)
2-1/2 (63mm) 2
SIGNAL RECEIVER CORD (LENGTH: 74-13/16)
7-1/16 (180mm)
5-1/8 (130mm)
INDOOR UNIT ON/OFF SWITCH
1-1/2 (38mm)
6-5/16 (160mm)
>
TIMER LAMP
(13/16) (20mm)
(2-13/16) (72mm)
CEILING
ROOM TEMP. 2-3/4 SENSOR (70mm) OPERATION LAMP
4-3/4 (120mm)
27-9/16 (700mm)
13/16 (20mm) OR MORE
15-3/4 (400mm) OR MORE
1-15/16 (50mm)
26-3/4 (680mm) 26 (660mm) 4x(P5-7/8)=23-5/8 (P150mm) (600mm)
2-1/4 (57.5mm)
13/16 (21mm)
1/2 (12.5mm)
SUSPENSION BOLT 4-M8~M10
SIGNAL TRANSMITTER 11/16 (18mm) 2-5/16 (58mm)
3-15/16 (100mm)
5x(P3-15/16)=19-11/16 (P100mm) (500mm) 29-1/8 (740mm) (SUSPENSION BOLT PITCH)
(1-3/4) (45mm) 24-7/16 (620mm)
11-13/16 (300mm)
16- 3/16 ( 4.7mm) HOLE (ALL AROUND)
2-3/8 (60mm)
8
1-7/8 (47mm) 3-9/16 (90mm) 13/16 (20mm) OR MORE
24-7/16(620mm)
19-11/16 (500mm)
12(300mm) OR MORE (SERVICE SPACE) (SUSPENSION BOLT PITCH)
27-9/16(700mm)
9-1/2(240mm) OR MORE
FDXS09/12LVJU
9 4
16-M5 HOLES (ALL AROUND)
6
24-7/16 (620mm)
13 (330mm)
3
6-11/16 (170mm)
1-3/16 (30mm)
3-15/16 (100mm) 7/8 (23mm)
3-1/8 (80mm) 3-15/16 (100mm)
6 (153mm) 6-5/16 (160mm) 13/16 (20mm)
1-15/16 (50mm)
6-11/16 (170mm) 7-1/16 (180mm)
7-7/8 (200mm)
3/8 (10mm)
7-7/8 (200mm)
7 14-M4 HOLES (ALL AROUND)
5
23-5/8 (600mm) 9
10 5x(P3-15/16)=19-11/16 (P100mm) (500mm) 22-13/16 (580mm)
NOTE) 1. IN CASE OF BACK-SUCTION, MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT. IN CASE OF BOTTOM-SUCTION, MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT. 2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER 6 3. MOUNT THE AIR FILTER AT THE SUCTION SIDE. 3-1/8 (80mm) SELECT ITS COLORIMETHOD (GRAVITY METHOD) 3-9/16 (90mm) 50% OR MORE. IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY) 5-1/2 (140mm) WHEN CONNECTING DUCT TO SUCTION SIDE. 3-15/16 (100mm) 4. PIPE SPECIFICATION
(
)
>
www.daikincomfort.com
5-1/2 (140mm) 3-1/8 (80mm)
5x(P3-15/16)=19-11/16 (P100mm) (500mm) 24-7/16 (620mm) >
10 9 8 7 6 5 4 3 2 1 NUMBER
PROTECTION NET AIR FILTER (ACCESSORY) SUSPENSION BRACKET POWER SUPPLY CONNECTION INFRARED RECEIVER UNIT CONNECTION CONTROL BOX DRAIN HOSE (ACCESSORY) I.D. 31/32( 25mm) (OUTLET) SOCKET FOR DRAIN VP20 (O.D. 1-1/32 ( 26mm)/ I.D. 25/32 ( 20mm)) GAS PIPE CONNECTION 3/8 ( 9.5mm) (FLARE CONNECTION) LIQUID PIPE CONNECTION 1/4 ( 6.4mm) (FLARE CONNECTION) NAME DESCRIPTION
3D074619
SS-DLV
Dimensions — Outdoor Units
MINIMUM SPACE FOR AIR PASSAGE
1-15/16
HANDLE
1-15/16
3-15/16
1-15/16
1-3/16
1-15/16
11-13/16
8 / 1 - 4
19-5/16
5-14/16
2
3-15/16
8 / 5 - 2 1/2
WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 47-1/4
4-HOLES FOR ANCHOR BOLTS (M8 OR M10)
DRAIN OUTLET (I.D φ5/8 HOSE FOR CONNECTION)
12-1/4
5-14/16
RXS09/12LVJU
BRAND NAME LABEL 8 / 1 - 0
3
2 / 1 - 2
TRAMINAL STRIP WITH GROUND TRAMINAL
MANUFACTURE'S LABEL
LIQUID STOP VALVE (φ1/4CuT)
4-1/8
WIRING INLET
CONDUIT MOUNTING PLATE SERVICE PORT
OUTDOOR AIR THERMISTOR
6-1/2
1 1/2
21-5/8
4 / 1 5/16 - 1
14/16
7-11/16 IN CASE OF REMOVING STOP VALVE COVER
GAS STOP VALVE (φ3/8 CuT)
3D074281
DRAIN OUTLET (I.D. φ5/8 HOSE FOR CONNECTION WITH DRAIN JOINT)
3-15/16
1-15/16
OUTDOOR TEMPERATURE THERMISTOR
2-1/2
28-15/16
IN CASE OF REMOVING STOP VALVE COVER MANUFACTURER'S LABEL 4-HOLES FOR FOUNDATION BOLTS TERMINAL STRIP (M8 OR M10) BRAND NAME PLATE WIRING INLET WITH GROUND TERMINAL
1-15/16
13-3/4
3-15/16
1-15/16
1-7/16
13
13-15/16
11-13/16 1-3/16
9/16
HANDLE
22-13/16
13-3/4
3-1/16
13-3/4
32-1/2 12-13/16 4-7/8 1/16
WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 47-1/4
MINIMUM SPACE FOR AIR PASSAGE
3-15/16
RXS15/18LVJU
CAUTION LABEL
6-1/8
3-1/2
DANGER
11/16
1-3/16
6-5/16
CONDUIT MOUNTING PLATE LIQUID STOP VALVE (φ1/4 CuT)
GAS STOP VALVE (φ1/2 CuT) SERVICE PORT
3D074452
SS-DLV
www.daikincomfort.com
7
Dimensions — Outdoor Unit RXS24LVJU MINIMUM SPACE FOR AIR PASSAGE
BRAND NAME LABEL
NAME PLATE
TERMINAL STRIP LIQUID STOP VALVE
13-3/4
3-15/16
7-1/2 GAS STOP VALVE
3-15/16
1-15/16
1-15/16
13/3/4
1-15/16
DRAIN OUTLET I.D. φ15/16 HOSE FOR CONNECTION. 14-13/16
13-3/4
3-15/16
4 4-5/8 1-1/8
1-3/4
4-CUTS FOR ANCHOR BOLTS WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 47-1/4 (M12)
12-5/8 13-3/4
5-1/2
(13-9/16~13-15/16) 14-15/16
2-13/16
35-7/16 24-7/16
OUTDOOR AIR THERMISTOR
3-1/16 4-1/4
1-15/16
4-15/16
4-1/16
3-9/16
16-1/8
30-5/16
GROUND TERMINAL
1-3/16 2-5/8
GAS PIPE (φ5/8 SINGLE UNION) LIQUID PIPE (φ1/4 SINGLE UNION)
3D074208A
8
www.daikincomfort.com
SS-DLV
Wiring Diagrams — Indoor Units
FTXS09/12LVJU PCB3 1
LED1 H1P
S49
BLK BLK BLK BLK BLK BLK BLK BLK BLK
LED2 H2P LED3 H3P
9
FU1 F1U
PCB1
S46 1
~
C102
C101
9
SW1
V1
H1
BLK
H2
RED GRN
3.15A
WHT
MR10
t˚
HA
RTH1 R1T 1
PCB4
S26
1
4
S41 S47 S32 1 3 1 2 16 8 10 12 14 2 5 3 4 6 15 13 11 9 7 1
PCB2
S48
1
RED BLU BRN ORG WHT
MS 3~
M1F
RED ORG YLW PNK BLU RED ORG YLW PNK BLU RED ORG YLW PNK BLU
BLK BLK BLK BLK
INTELLIGENT EYE SENSOR
WIRELESS REMOTE CONTROLLER
S1
4
S25 1
BLK BLK BLK BLK
4
7
BLK
BZ
t˚
3
R2T
SIGNAL RECEIVER
MSW
MSW
MSW
M1S
M2S
M3S
3
2
OUTDOOR
3 FIELD WIRING.
CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.
FG
S21
2
1
GRN / YLW
H3
TRANSMISSION CIRCUIT
1
X1M
INDOOR
: BUZZER BZ C101, C102 : CAPACITOR FG : FRAME GROUND : FUSE F1U H1P~H3P : PILOT LAMP : MAGNETIC RELAY MR10 M1F : FAN MOTOR M1S~M3S : SWING MOTOR PCB1~PCB4 : PRINTED CIRCUIT BOARD R1T, R2T : THERMISTOR : CONNECTOR S1~S49 : OPERATION SWITCH SW1 : VARISTOR V1 X1M : TERMINAL STRIP : PROTECTIVE GROUND
C: 3D058246F
FTXS15/18/24LVJU PCB3
S49 1
LED1 H1P LED2 H2P LED3 H3P
9
BLK BLK BLK BLK BLK BLK BLK BLK BLK
SW1
~
C102
C101
9
V1
H1
3.15A H2
MR10
1 3
4
S25 1
BLK BLK BLK
4
BLK
S47 S32 S41 1 3 1 2 16 8 10 12 14 2 5 3 4 6 15 13 11 9 7 1 BLK BLK BLK
INTELLIGENT EYE SENSOR
1
WIRELESS REMOTE CONTROLLER
PCB2
S48
1
SIGNAL RECEIVER
3
RED BLU BRN ORG WHT
MS 3~ M1F
t˚ R2T
MSW
MSW
MSW
M1S
M2S
M3S
2
RED GRN
3
3
OUTDOOR
FIELD WIRING.
NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.
BLK
S36
S1
2
1
CAUTION
FG
7
X1M
WHT
GRN / YLW
H3
TRANSMISSION CIRCUIT
HA
RTH1 R1T
BLK
RED ORG YLW PNK BLU RED ORG YLW PNK BLU RED ORG YLW PNK BLU
PCB4
FU1 F1U
S21 t˚
BZ
1
PCB1
S46 1
INDOOR
: BUZZER BZ C101, C102 : CAPACITOR : FRAME GROUND FG : FUSE F1U : PILOT LAMP H1P~H3P : MAGNETIC RELAY MR10 : FAN MOTOR M1F M1S~M3S : SWING MOTOR PCB1~PCB4 : PRINTED CIRCUIT BOARD : THERMISTOR R1T, R2T : CONNECTOR S1~S49 : OPERATION SWITCH SW1 : VARISTOR V1 : TERMINAL STRIP X1M : PROTECTIVE GROUND
C: 3D060942H
SS-DLV
www.daikincomfort.com
9
Wiring Diagram — Indoor Unit FDXS09/12LVJU A1P
A2P
1
S1
S26 1
H2 FOR ( TERMINAL CENTRALIZED CONTROL )
S21
S1W SIGNAL RECEIVER
F1U 3.15A
V1TR
LED LED LED H1P H2P H3P
H1
10
10
2 RTH1 1
2 S32 1
t°
BRN BRN
R1T
t° R2T
WIRELESS REMOTE CONTROLLER
S1
1
S7
6
3
RED
: PROTECTIVE GROUND C1 : CAPACITOR (M1F) F1U : FUSE
1
YLW WHT
PPL BLU
X1M 1
WHT
2
RED
3
M 1~ M1F
Q1M 130°C
C1
H1P~H3P M1F A1P~A2P Q1M
R1T~R2T S1~S32, RTH1 S1W V1TR X1M
1 2 → 3 OUTDOOR
GRN GRN/YLW
BLK
GRY
3
INDOOR
H3 TRANSMISSION GND CIRCUIT
BLK
FIELD WIRING. CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.
: PILOT LAMP : FAN MOTOR : PRINTED CIRCUIT BOARD : THERMAL PROTECTOR (FOR MOTOR) : THERMISTOR : CONNECTOR : OPERATION SWITCH : TRIAC : TERMINAL BLOCK
C: 3D073998B
10
www.daikincomfort.com
SS-DLV
Wiring Diagrams — Outdoor Units
RXS09/12LVJU
FIELD WIRING
GRN GRN
Z2C N=2
S100 1 2
PCB1
WHT
OUTDOOR NOTE 1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS. C5, C6, C119 : CAPACITOR DB1, DB2, DB3
:
DIODE BRIDGE
FU1, FU2, FU3
:
FUSE
IPM1, IPM2
:
INTELLIGENT POWER MODULE
L1 L2
:
LIVE
L1
:
COIL
L1R
:
REACTOR
M1C
:
COMPRESSOR MOTOR
M1F
:
FAN MOTOR
MRCW, MR30, MRM10, MRM20 :
2
Q1L
:
OVERLOAD PROTECTOR
PCB1, PCB2, PCB3
:
PRINTED CIRCUIT BOARD
–
S10
FU2 3.15A
9
~ –
+
MRCW
S20
6
S110
1
S90
6
t°
t°
2
S40
V1, V2, V3 X1M Y1E
S110, HL3, HN3, X11A :
CONNECTOR
R1T, R2T, R3T
:
THERMISTOR
SA1
:
SURGE ABSORBER
SW1
:
FORCED COOLING OPERATION SWITCH (SW1)
VARISTOR
:
TERMINAL STRIP
M1F
ELECTRONIC EXPANSION VALVE COIL
:
REVERSING SOLENOID VALVE COIL
Z1C, Z2C, Z3C : GR
X11A
Z1C N=4 V W MS U 3~ M1C
MS 3~
Q1L
: :
Y1S
W V U –
S70 1 4 7 10 11 12 13
1
(OUTDOOR) (DISCHARGE) (CONDENSER)
S70, S80, S90, S100
IPM2
–
t°
R1T R2T R3T
Y1E
PCB3
1
Y1S
M
SW1
S80
3
S10, S11, S20, S40
MAGNETIC RELAY
C119
DB3 ~ +
1
1
+
–
RED
9
E2
+
RED
S11
PCB2
–
C6
Q1
~ –
V1
+
C5
DB2 ~ +
~ –
BLU
E1
1
WHT BLK BLK BLK BLK BLK BLK BLK BLK
HA2
GRY
YLW
SA1
HL3
ORG
1
HA1
BLU
MR30
GRN/YLW
GR
FU1 3.15A
HN3
BLU
HL2
V3
L2
HN2
YLW
GR
L1
MRM10
V2
+
YLW RED WHT BLK BRN ORG BLU
S
BLK
RED
IPM1
HR2 DB1 ~ +
GRY
3
AC2
WHT
L1R
BRN
BLK BLK BLK BLK BLK BLK
WHT
HR1
L1
RED
L2 2
MRM20
N=2 FU3 Z3C AC1 20A
RED
3
BLK
RED
2
X1M L1 1
WHT
1
WHT YLW ORG BLU
INDOOR
FERRITE CORE
:
PROTECTIVE GROUND
:
GROUND
3D074402A
RXS15/18LVJU FIELD WIRING
CAPACITOR DIODE BRIDGE FUSE INTELLIGENT POWER MODULE LIVE
L803, L804 M1C
: REACTOR : COMPRESSOR MOTOR
M1F
: FAN MOTOR
MRCW, MRM10, MRM20, MR30 : MAGNETIC RELAY Q1L : OVERLOAD PROTECTOR
SS-DLV
IN CASE OF COOLING ONLY TYPE
3
PRINTED CIRCUIT BOARD
CONNECTOR
R1T, R2T, R3T
:
THERMISTOR
SA1
:
SURGE ABSORBER
www.daikincomfort.com
V1, V2, V3 X1M
6
Z4C N=1
7
: :
MS 3~
M1F
: :
ELECTRONIC EXPANSION VALVE COIL REVERSING SOLENOID VALVE COIL
GR
:
PROTECTIVE GROUND
Z1C, Z2C, Z3C, Z4C : :
Z1C N=4
W
V
MS 3~
X11A
U M1C
VARISTOR TERMINAL STRIP
Y1E Y1S
,
BRN
PPL
1
Q1L t° t° t° M R1T R2T R3T Y1E (OUTDOOR) (DISCHARGE) (CONDENSER)
Y1S
PCB1, PCB2 : S10, S11, S12, S20 S40, S70, S80, S90 HL3, HN3, X11A :
6
S70 4 321
RED
1
1
S90
FU2 3.15A
YLW
S80
3
~ –
S20
S40 2 1
RED
1
DB3 ~ +
W V U
YLW
S80
S12
DC_P2 DC_N2
11
BLU
4
GRY
MRCW
V1
DC_P1 DC_N1
BLU
1
YLW
–
PCB2
BLU BRN ORG WHT
PCB1
11
S10
RED
HL4
+ + C7 C8 – –
~ –
1
BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK
BLK BLK
HN4
+
BLK BLK BLK BLK BLK BLK
S11
HN3
IPM
L804
RED
MR30
E2
: : : : :
WHT
1
FU1 3.15A
OUTDOOR
NOTE 1. C7, C8 DB1, DB3 FU1, FU2, FU3 IPM L1, L2
HN2
WHT YLW ORG BLU
SA1
MRM10
RED
E1
HL3 DB1 ~ + BLU
HL2
RED
N=4 Z2C
GRN
GR POWER SUPPLY 208/230V 60Hz
GRN
L1 L2
L803
MRM20
N=5 FU3 X1M Z3C HL1 30A L1 1 BLK HN1 V2 L2 2 WHT S 3 RED GR V3 GRN/YLW
INDOOR TO INDOOR UNIT 1 2 3
FERRITE CORE GROUND
3D072837
11
Wiring Diagram — Outdoor Unit RXS24LVJU L1R
GRN
2
1 S10
MR30 MRC/W
BLU BLU BLU BLU BLU
RED BLK WHT GRN
1 S52 5
1 S102 5
: FERRITE CORE : TERMINAL STRIP : ELECTRONIC EXPANSION VALVE COIL : VARISTOR : SURGE ABSORBER : FUSE
PM1
PCB2 LED A S2
MRM10, MRM20 MRC/W, MR30 R1T~R3T S2~S102 LED A
3.15A
V100
6(P)
+ + + S70 1
7(N)
U V W
5 4 3
M1F MS 3~
BLU BRN ORG WHT
N=3 Z4C X11A
M1C U V MS YLW W 3~
RED
RED
BLU
BLU
YLW
S40
V5
Y1S
N=1 Z5C
Q1L
PCB1
1S1015 6 4 S80 1
SW1 Z1C~Z6C X1M, X2M Y1E V2, V3, V5, V9, V100 SA2 FU1, FU2, FU3 AC1, AC2 U, V, W, X11A E1, E2 HR1, HR2
8
V3
RED
1 S51 5
FIELD WIRING
9
FU2 3.15A
SHEET METAL INDOOR
1
V9
AC2
RED
MRM10
RED
BLK BLK
BLU
MRM20
M
4
t˚
t˚
t˚
R3T R2T R1T (OUTDOOR) (DISCHARGE) (CONDENSER)
Y1E
SW4
1
1 S90 6
1 S20 6
BLK
BLK
X2M 1 2 3
1 2 3
Z3C N=3 WHT
GR
TO INDOOR UNIT
BRN
SA2 FU1 V2 30A
FU3 7
BLU
L2
AC1
HR2
GRY
N=4 Z2C
HR1
RED
POWER SUPPLY L1 L2 GR
Z1C N=6 E2
E1
WHT YLW ORG BLU
L1
BLU
X1M
WHT
Z6C N=1
RED
GRN YLW
OUTDOOR
: MAGNETIC RELAY : THERMISTOR : CONNECTOR : PILOT LAMP
L1, L2 : LIVE SW1 : FORCED COOLING OPERATION SWITCH (SW1) SW4 : LOCAL SETTING SW (SW4)
: CONNECTOR
M1C M1F L1R Q1L PM1 PCB1, 2 Y1S SHEET METAL GR
: COMPRESSOR MOTOR : FAN MOTOR : REACTOR : OVERLOAD PROTECTOR : POWER MODULE : PRINTED CIRCUIT BOARD : REVERSING SOLENOID VALVE COIL : TERMINAL STRIP FIXED PLATE : PROTECTIVE GROUND : GROUND
3D074292
Accessories Indoor Unit ARC452
Handheld Wireless Remote Controller (included)
BRC944B2-A08 comes with 26' cord
Wired Remote Controller
DACA-BRCW901P10 (for SlimDuct)
Remote Controller Cable, Plenum Rated, 10 ft
DACA-BRCW901P25 (for SlimDuct)
Remote Controller Cable, Plenum Rated, 25 ft
DACA-TS1-1
Daikin ENVi Intelligent Thermostat Kit
DACA-CP3-1
Condensate Pump
Outdoor Unit DACA-WB-3
Powder Coated Wall Mounted Bracket
Our continuing commitment to quality products may mean a change in specifications without notice. ©2016 daikin manufacturing company, l.p. • Houston, Texas • Printed in the USA.
12
www.daikincomfort.com
SS-DLV