ZONING USER’S INFORMATION MANUAL PREMIUM HIGH DEFINITION TOUCH SCREEN COMMUNICATING CONTROL MODELS: S1-TTSCC

Energy Saver

Need Assistance? For assistance with this product please visit http://www.yorkupg.com Read and Save This Manual ® U.S. Registered Trademark US Patent No. Copyright © 2012 Johnson Controls, Unitary Products. All rights reserved

Table of Contents QUICK REFERENCE . . . . . . . . . . . . . . . . . 2 HOME SCREEN . . . . . . . . . . . . . . . . . . . 2 PROGRAMMING & OPERATION . . . . . . . . 3 MANAGE ZONES . . . . . . . . . . . . . . . . . 3 USING PROGRAM SCHEDULES . . . . . 3 VIEWING AN EXISTING PROGRAM SCHEDULE . . . . . . . . . . . . . . . . . . . . . . 4 ASSIGNING PROGRAM SCHEDULES TO ZONE CALENDARS . . . . . . . . . . . . . . . 4

TEMPERATURE OVERRIDE . . . . . . . . . 5 SCHEDULE OVERRIDE . . . . . . . . . . . . . 5 VACATION HOLD . . . . . . . . . . . . . . . . . . 5 FAN SETTINGS . . . . . . . . . . . . . . . . . . . 6 HUMIDITY SETTINGS . . . . . . . . . . . . . . 6 SYSTEM STATUS . . . . . . . . . . . . . . . . . 6 ZONING SETTINGS . . . . . . . . . . . . . . . . 6 OTHER SETTINGS . . . . . . . . . . . . . . . . 6 SYSTEM OPERATION . . . . . . . . . . . . . . 7

This document is intended to supplement the User’s Information Manual for the Touch Screen Communicating Control (S1-TTSCC) and provide additional Zoning information.

Johnson Controls Unitary Products

1078336-UUM-A-1213

1078336-UUM-A-1213

QUICK REFERENCE HOME SCREEN Zone Current Indoor Temperature

Current Date & Time

Current Outdoor Temperature (if communicating outdoor equipment is installed)

Zone Name

Living Room

11:07AM Thu 21 Jul

62°

Return to Home Screen

70°

Zone Temperature Override

ON

Humidity 30%

78°

Zone Schedule Override (at Master Touch Screen only) Quick Help

Zone Fan Setting (if display setting is enabled)

72° Menu M

Alert: Change Filter Screen

Zone Cool Mode

Zone Humidity Setting (if display setting is enabled)

Auto

Zone Heat Mode

System Popup Alerts (at Master Touch Screen only)

Zone Current Indoor Humidity (if display setting is enabled) Menu

NOTICE The Home Screen for Non-Programmable and Programmable Modes include similar additions for Zoning.

2

Johnson Controls Unitary Products

1078336-UUM-A-1213

PROGRAMMING & OPERATION MANAGE ZONES 1. Press MENU in the bottom right corner of your screen.

Living Room

11:07AM Thu 21 Jul

62°

70°

ON Auto

Humidity 30%

78°

72° Menu M

Alert: Change Filter

2. Press Manage Zones button.

Living Room Emergency Heat

Fan

Humidity Status Settings

Manage Zones

Dealer

Tools

Clean Schedule Close

Alert: Change Filter

3. This screen gives you an overview of each zone. To make changes or view further details of a specific zone press on the desired zone. 4. Press MENU then Manage Zones and select the Master Zone to return to the Master Zone View.

Living Room / Manage Zones Living Room

Kitchen

68°

72° Override

Master Bedroom

72°

68°

70°

Basement

72°

Cancel

NOTICE The Manage Zones button can be used to view or adjust settings in any other zone. However, some settings can only be adjusted at the Master Touch Screen. When using the Manage Zones feature, make sure to note in the upper left corner of the screen which zone you are viewing and adjusting.

USING PROGRAM SCHEDULES Program schedules cannot be viewed or adjusted in Non-Programmable mode.

NOTICE In order to create/edit program schedules, change the View/Mode to either Programmable or Advanced Programmable. Schedules are accessible at the Master Touch Screen only.

Johnson Controls Unitary Products

3

1078336-UUM-A-1213 1.Press MENU. 2.Press Schedule icon. 3.Press Viewer Assign to Calendar a. The New, Edit or Copy icons to create a new or Import/ edit an existing schedule. Refer to the User's InforExport mation Manual for more details. Delete b. The Delete icon to delete an existing schedule. Refer to the User's Information Manual for more Save Cancel details. c. The Viewer icon to view existing schedule summaries. See below. d. The Import/Export icon to import or export a program schedule. Refer to the Touch Screen Communicating Control User's Information Manual for more details. e. The Assign to Calendar icon to assign an existing schedule to the calendar. See below. Schedule Create or edit schedules Energy Saver New Schedule 1 Edit Schedule 2 Schedule 3 Copy

VIEWING AN EXISTING PROGRAM SCHEDULE 1. Select your desired zone (i.e. Living Room). 2. Press OK.

Select Zone Apply to Schedule:

Living Room

Kitchen

Bedroom 1

Dining Room

Den

Master Bedroom OK

3. Select Schedule to view by pressing left or right arrows. 4. Select Day to view. 5. Press Close. 6. Repeat steps 1 through 5 for each zone.

Living Room / Schedule Viewer View

(Active in Calendar)

Schedule 3

Mo

Tu

We Th

Fr

Sa

Su

Awake

Day

Return

Sleep

73° 70° 6:00am

73° 70° 8:00am

70° 65° 5:00pm

73° 70° 10:00pm

Close

ASSIGNING PROGRAM SCHEDULES TO ZONE CALENDARS 1. Select your desired zone (i.e. Living Room). 2. Press OK.

Select Zone Apply to Schedule:

Living Room

Kitchen

Bedroom 1

Dining Room

Den

Master Bedroom OK

4

Johnson Controls Unitary Products

1078336-UUM-A-1213

Living Room / Schedule Select Schedule: Assign to Calendar Energy Saver Winter Spring Schedule 1 Dec Jan Feb Mar Apr May Schedule 2 Schedule 3 June July Aug Sep Oct Nov All Year

3. Select Schedule to assign to selected zone calendar by pressing up or down arrows. 4. Select individual Months, Seasons, or All Year for the selected zone calendar assignment. 5. Repeat steps 3 - 4 for each schedule's calendar assignment. 6. Press Done to save all changes. 7. Repeat steps 1 through 6 for each zone.

Summer

Fall Cancel

Done

TEMPERATURE OVERRIDE ( Advanced Programable Mode) 1. Press Thermometer icon. 2. Use the slider to set the desired override temperature.

Touch Screen Master View 3. Press Pick Duration button. 4. Select the duration for running the temperature override. a. Until Cancelled - holds temperature until cancelled. b. Until specific Date & Time - holds temperature until specified date and time. c. Until program schedule Next Event - hold temperature until next schedule event.

Touch Screen Sensor View 5. Press the Apply button.

View at Master Touch Screen 11:07AM Thu 21 Jul

75°

Pick Duration

Quick

70°

50°

Quick

85°

Menu

Alert: Change Filter

View at Touch Screen Sensor 11:07AM Thu 21 Jul

75° 50°

70°

Alert: Change Filter

Apply

85°

Menu

SCHEDULE OVERRIDE The schedule override feature is available at the Master Touch Screen only. Refer to the User's Information Manual included with the Touch Screen Communicating Control for more details.

VACATION HOLD The vacation hold feature is available at the Master Touch Screen only. The temperature, fan, and humidity settings for the specified vacation period will be applied to all zones. Each zone will be controlled individually to meet these settings. Refer to the Touch Screen Communicating Control User's Information Manual for more details.

Johnson Controls Unitary Products

5

1078336-UUM-A-1213

FAN SETTINGS The fan mode and operation interval settings can be specified for each zone. However, the fan percentage setting will be applied to all zones. The actual airflow delivered to each zone during fan operation will depend on the airflow settings made for each zone during installation and the number of zones that are calling for fan operation at any given time.

HUMIDITY SETTINGS Humidity settings can be specified for each zone having Touch Screen Communicating Controls. Zone Sensors and Zone Displays do not include the humidity sensing feature.

Use of the "Auto" Humidity Function is highly recommended. In this mode, the Master Touch Screen adjusts the humidity setting to maximize comfort during heating and cooling seasons. Improper humidity settings can result in extreme humidity levels and property damage.

SYSTEM STATUS The status of the system including the zoning components can be viewed in the system map. Press the Accessories button to see the status of the Zone Panel. Press the Thermostat icon for information on each zone sensor.

ZONING SETTINGS Your new Touch Screen Communicating Control is preset to Zoning Mode. To change the Zone Mode: 1. Press MENU in the bottom right corner of your screen 2. Press Settings icon 3. Press Zoning icon 4. Select Zoned or Non Zoned. 5. Press the Edit button to change the name for each Zone.

NOTICE In Non Zoned Mode the dampers to all Zones will be open and the zoning system can only be controlled from the Master Touch Screen.

OTHER SETTINGS Date / Time The Master Touch Screen sets and updates the date and time on all zone sensors. Therefore, the date and time can only be set at the Master Touch Screen.

Security Security is enabled and a PIN specified only at the Master Touch Screen. Security settings including the PIN apply to all Touch Screen Sensors.

6

Johnson Controls Unitary Products

1078336-UUM-A-1213

View / Mode The View Mode for the Master Touch Screen and all Touch Screen Sensors is specified at the Master Touch Screen. The Sleep Screen can be specified for each Touch Screen Sensor.

Temperature Format Temperature format (Fahrenheit or Celsius) is specified at the Master Touch Screen but applies to all Touch Screen Sensors and Zone Displays.

Language The View Mode for the Master Touch Screen and all Touch Screen Sensors is specified at the Master Touch Screen.

SYSTEM OPERATION If the zoning system is equipped with power open / power closed dampers, the Master Touch Screen may under certain conditions redirect airflow to zones that are not calling for conditioning (heating or cooling or continuous fan) to balance the airflow in the system. The Master Touch Screen manages the airflow adjustments so that comfort is maintained in all zones.

NOTICE Under some conditions, the Master Touch Screen may temporarily direct conditioned air to zones that are not calling for conditioning or continuous fan operation. This is normal operation.

Johnson Controls Unitary Products

7

NOTES

Subject to change without notice. Published in U.S.A. Copyright © 2013 by Johnson Controls, Inc. All rights reserved.

York International Corp. 5005 York Drive Norman, OK 73069

1078336-UUM-A-1213 Supersedes: 689281-UUM-A-0812