XELLEX BATTERY (HK) LIMITED SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD 23A-12V TECHNICAL SPECIFICATION

XELLEX BATTERY (HK) LIMITED SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD 23A-12V TECHNICAL SPECIFICATION DRAFTED BY: CHECKED BY: APPROVED BY...
Author: Mavis Payne
7 downloads 1 Views 137KB Size
XELLEX BATTERY (HK) LIMITED SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD

23A-12V TECHNICAL SPECIFICATION DRAFTED BY: CHECKED BY: APPROVED BY:

CLIENT ADMITED SIGN:

SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD

HONGKONG XELLEX BATTERY CO., LTD

6/F, Jiayu Bldg, Dong’er Xiang 15#, Gongyuan Road, 22 Industry Zone, Bao’an District, Shenzhen, PRC.

Flat A, 12/F., Wing Sing Commercial Centre, 12-16 Wing Lok Street, Hong Kong

TEL:0086-755-27664401 27664402 27664403 FAX: 0086-755-27806777 27664407 Website: www.xellex-battery.com Email: [email protected]

TEL: 00852-28507117 FAX: 00852-25819986 Website: xellex.en.alibaba.com Email: [email protected]

The Technical Specifications hereinafter is only applicable to the Hg & Cd Free Alkaline Zinc Manganese Dioxide 23A-12V type battery, which was provided by Xellex Battery Co., Ltd. All the practical technical data, which were used to describe Battery Performance involved in the Specifications are obtained from the relevant experiments to the products of Xellex. Rights reserved to take relevant rectifications or modifications to the structure and performance of the products without prior notice. Page

1

of

5

Spec. NO.:XL-23A-12V

Edition:Rev.00

Date:2005-08-28

1.Scope The Specifications is solely applicable to the “Xellex” Hg & Cd Free Alkaline Zinc Manganese Dioxide Battery---23A-12V. 1.1Designations Xellex :23A-12V

IEC :

JIS :

ANSI :

Other:23A , V23GA

1.2 Reference Document IEC 60086-1(2000)

--- Primary Batteries - General

IEC 60086-2(2000)

--- Primary Batteries – Specification Sheets

2. Chemical System Alkaline Electrolyte--- Zinc-Manganese Dioxide Battery (0%Hg and 0%Cd added)

3. Dimensions Diameter: 10.1±0.2 mm

Height: 28.0±0.5 mm

4.Nominal Voltage:12 Volts 5.Average Weight:8.2 g 6. Nominal Capacity 41mAh (20KΩ continuous discharge,Temp.:20±2℃,CDV:7.2 Volts)

7. Electrical Performance (Conditions:100Ω±0.5% load resistance, Measuring time 0.3 Seconds, Temperature at 20±2℃, Tested within 30 Days after delivery)

New Battery After 12 Mths Shelf Time at room Temp

Off-load

On-load

Voltage(V)

Voltage(V)

≥12.2

≥7.0

≥12.0

≥6.8

Acceptance Standard

MIL-STD105E,Class II,Double Sampling,AQL=0.4

*The Hair Spring Ampere Meter with ±0.5% Accuracy (0.5 Level) shall be used.

8.Service Output (Conditions:Test Temp.20±2℃ ,Relative Humidity: 45%-75% Test within 30 Days after delivery)

Page

2

of

5

Spec. NO.:XL-23A-12V

Edition:Rev.00

Date:2005-08-28 Average Minimum Discharge

Discharge Condition

Time

Test Standards

Cut-off Discharge

Daily Discharge

Discharge

Load

Time

Voltage

After 12 Mths New Battery

room Temp.

(V) IEC Standard

20KΩ

24 Hours

7.2

Shelf Time at

≥87Hours

≥80Hours

Acceptance Criteria:9 batteries shall be tested for each discharging standard, the Average Discharging Time should be equal to or above the Average Minimum Discharging Time required. Moreover, the total amount of the batteries whose Average Discharging Time is less than 80% of the time required shall not exceed 1, Thus, the ADT of the batteries can be recognized accorded with the requirements

9.Electrolyte Leakage Proof Characteristics

Item

Condition

Period

Characteristic

Acceptance

s

Standard

There shall be no 20KΩ Over-discharge Characteristics

continuous

deformation

discharge at Temp.: 20 ± 2 ℃ Relative

exceeding the 48 Hours

specified

Humidity : 65 ±

dimensions,

15%RH

nor leakage recognized by human eye

10.Safety Characteristics

Page

3

of

5

N=30,Ac=0,Re=1

Spec. NO.:XL-23A-12V

Item

Edition:Rev.00

Condition

Period

Date:2005-08-28

Characteristics

Acceptance Standard

Temp: 20±2℃ Short Circuit Characteristics

Relative Humidity: 60±15%

There shall be

Directly connect the Positive

24 Hours

& Negative Terminals with a

no

explosion

N=9,Ac=0,Re=1

of battery

wire

11.Marking

The following markings will be printed, stamped or impressed on the body of

the battery: (1)Designation :23A-12V (2)Manufacturer’s name, abbreviation or brand:XELLEX (3)Nominal Voltage :12V (4)Polarity :“+”, “-” (5)Warning: Battery may explode or leak if recharged or disposed of in fire. (6)Expiry Date(Guarantee Period):The Date which shows on the labels of the finished product is used to indicate the Quality Assurance Period before it is used.

12.Caution for Use (1)Since the battery is not manufactured for recharging, there are risks of electrolyte leakage or causing damage to the device if the battery is charged. (2)The battery shall be installed with its “+” and “-”in the right position. (3)Short-connecting, heating, disposing of into fire and disassembling the battery are prohibited.

13.Shelf Life: 12 months after delivery under proper storage conditions.

14.Discharging Curves ⑴20KΩ,24 Hours/Day, E.P.V: 6.0V Continuous Discharging Curves(Figure 1)

15.Battery Dimensions & Structure(Figure 2)

Page

4

of

5

Spec. NO.:XL-23A-12V

Edition:Rev.00

Date:2005-08-28

Figure 1:

(v) 13.0 12.0 11.0 10.0 9.00 8.00 7.00 6.00 5.00

0

16

32

48

Figure 2:

Page



of 5

64

80 96 HOURS OF SERVICE