Klaxon Signals provides a range of warning sirens for operation
■
motor driven sirens suitable for safe and hazardous locations, and
Low, medium and high output siren options. Ranges from 106dB – 127dB at 30 meters.
in various environments. The range includes both, conventional
■
Pre-recorded or live voice messages in addition to traditional
the more sophisticated and flexible electronic siren systems for safe
tones. Different voice messages can be broadcast to
area operation.
different areas simultaneously depending on the situation in each area.
Motor Driven Sirens
■
Motor driven sirens are manufactured from cast aluminium and steel for use in outdoor environments. They produce a powerful
determines the operational capability of the siren.
■
universally recognised emergency notification signal. ATEX
supply is only required to maintain battery charge.
■
Features Simple robust technology.
■
Rugged construction.
■
Universally recognised emergency signal.
■
Custom built control panels using hardwired or radio technology.
Battery powered siren operation means loss of site power has no effect on the functionality of the siren. An AC power
approved models are available for use in hazardous areas.
■
Perform silent tests at a user defined time period which
Low installation costs because the siren only requires a 110/230V AC supply instead of the 400V AC 3 phase supply required for motor driven sirens.
■
Up to 8 different user defined warning signals can be activated via volt free contacts and more when a RS485 interface is used as a means of control.
■
Regional and Local Control. Multiple local, geographically separated warning systems can be alerted through one
Electronic Siren Systems
regionally controlled system, such as an emergency centre or
Electronic siren systems consist of,
remotely via a computer with internet access.
■
Introduction
Service
Klaxon Signals have been supplying warning systems to the
Klaxon’s wide area warning systems provide a full product and
emergency warning sector for over 50 years. Our wealth of
service combination incorporating pre/post project evaluation,
experience in the field stems from the vast knowledge we
staff training and maintenance for a tailor made solution to meet
have gained by providing notification solutions for a broad
customer requirements.
spectrum of clients. These include clients from COMAH sites, Petro Chemical, Nuclear, Civil Defence, Weather Warning
Our technical experts in the field will first assess and fully
and Construction industries.
understand your safety requirements, then carry out a complete
An array of siren horns manufactured from Cast Aluminium
■
mounted on a mast. The horns can be mounted in an omni or uni directional configuration depending on the shape of the sound coverage required.
■
The Controller/s monitors and controls siren operation.
■
A full range of communication channels are available: stand
Siren system can be charged from a solar panel array for use in remote locations.
■
Variable sound levels for each warning signal enables on-site and off-site warning through the same siren.
alone hard wire switch control; computer system control; radio and/or satellite controlled link units.
site survey before submitting a proposal for your consideration. The Our expert advice and extensive product range will ensure you
proposal will be a detailed document explaining the type of siren
receive a warning solution that meets all your safety requirements
and control arrangement that is required to meet your specific
within budget. So whatever your requirement maybe you can rest
safety needs.
assure that we will take care of the project from start to finish. Once we receive your approval we will assemble the system to We can offer an integrated warning solution for both, indoor and
your specification before delivering it to your site. We would also
outdoor areas of a site using one homogenous control system for
offer staff training for all relevant personnel within your company.
a complete warning solution; the type of site could vary from a power plant to a civil warning area.
Our sirens come with a one year warranty period and require very low maintenance. Even after the warranty period is over we still
Our truly global project portfolio spreads across the UK, Europe,
provide ongoing on-site support and technical assistance.
Asia, Australia and the Middle East. We take pride in our sirens and control equipment being of the highest quality for optimum performance and reliability.
2
Call to order: +44 (0)161 287 5555
Visit us at: www.klaxsonsignals.com
3
Introduction
Contents
Electronic Siren Range Superior Range
Value Range
Superior Portable Range
Value Portable Range
ES1/2 S
ES1/2 V
ES1/2 SP
ES1/2 VP
ES1/3 S
ES1/3 V
ES1/3 SP
ES1/3 VP
ES2 S
ES2 V
Introduction
Page 2
■
Overview
Page 2
■
Service
Page 2
■
Products
Page 3
■
Client Portfolio
Page 4
ES3 S
Motor Driven Sirens
ES4 S
Motor Driven Siren Range Sirens
Sirens with heaters
Hazardous Area sirens
GP6
GP6
FP6
GP10
GP10
GP12
GP12
GP Range
Page 7
■
FP Range
Page 8
■
Sound Coverage Plot
Page 9
Electronic Sirens ■
FP10
Siren Control ■ Radio Electronic Siren
Radio Motor Driven Siren
Hardwired Electronic Siren
Licence Free System
Licence Free System
Switch Box
Licensed System using
Licensed System using
CMC4
Motorola radio technology
Motorola radio technology
CMC8
Hardwired Motor Driven Siren Custom Built Panels
■
DT 11 PC with Talos 20 software
Client Portfolio ■
Shell
■
Designed and supplied warning systems for a number of Shell
Pfizer
Page 10
Superior Range
Page 11
SIP-51 HMI
Page 12
CMC-4 HMI
Page 12
CMC-8 HMI
Page 13
Talos 20 HMI console
Page 13
Radio Control Equipment
Page 14
Value Range
Page 15
SIP-51 HMI
Page 16
DT-11 HMI
Page 16
Radio Control Equipment
Page 17
Portable Range
Page 18
Superior portable Range
Page 18
Value portable Range
Page 19
Sound coverage Plot
Page 20
Control Options
Page 21
Comparison chart
Page 22
Provided a warning solution for their chemical plant in Cork.
oil refinery sites across the UK.
■ ■
Page 6
■
Immingham Docks
Scottish Gas
The warning system we provided was designed to clear the
Provided an off-site warning system for Scottish Gas’s gas
dock area in the event of any danger.
■
Superior & Value Range
Page 22
storage site.
■ ■
Exxonmobil
IOM Airport
Designed and supplied a warning system for Exxonmobil’s
A warning system was designed and implemented to warn
COMAH site in St Fergus, Scotland.
personnel about potential hazards which may occur on the tarmac.
4
Call to order: +44 (0)161 287 5555
Visit us at: www.klaxsonsignals.com
5
Motor Driven Sirens
GP Range The GP range of conventional motor powered sirens provides a basic solution to address wide area mass alert signalling for all industrial, civil, commercial and environmental requirements. The products are of simple rugged construction and provide a low frequency traditional air raid sound.
Main Features ■
Audibility range between 106db @ 30metres for the smallest unit
GP6 Siren
to 121db @ 30metres for the largest unit. Sirens in this range in increasing order of sound output are the GP6, GP10 & GP12 units.
■
475Hz constant tone signal for the GP6 & GP10 sirens and a combined 470/560Hz constant tone signal for the GP12 siren.
■
Roughly omni-directional sound coverage which peaks in the direction of the front of the stator.
■
400Vac +/- 10% 50Hz 3 phase nominal power supply requirement. (Alternative voltages and frequencies available on request).
■
Operating temperature range for the standard GP6 & GP10 units of -20 to +40 degrees C, (Increased temperature range units available on request), and for the GP12 of -20 to +55 degrees C.
■
Cast aluminium & steel construction.
■
Environmental rating of IP55.
■
If the power supply to the sirens is pulsed to enable the siren to
GP10 Siren
produce a ‘wail’ tone then the maximum run time of the siren is reduced from continuous for constant tone to 15 minutes.
■
Custom built control units can be supplied to enable the siren to produce the ‘wail’ tone signal and associated controls.
■
If mounted in a climate where icing can occur the unit should be fitted with thermostatically controlled heaters.
GP12 Siren
Numeric Information
6
Call to order: +44 (0)161 287 5555
Siren Type
Motor Power
Current Rating
Weight
Dimensions: Overall Length Width & Height
Dimensions: Rotor Diameter
GP6
2.2kw
4.5A
52kg
460 x 400 x 440mm
400mm
GP10
5.5kw
11A
98kg
540 x 490 x 560mm
500mm
GP12
11kw
18A
208kg
760 x 500 x 590mm
500mm
Visit us at: www.klaxsonsignals.com
7
Motor Driven Sirens
FP Range
Sound Coverage Plot
The FP range of conventional motor powered sirens provides a
Below are typical sound coverage plots for the GP & FP range of
basic solution to address wide area mass alert signalling in
siren and anticipated coverage distance in clear still air on level
hazardous area locations for all industrial, civil, commercial and
terrain with no obstructions.
environmental requirements. The products are of simple rugged construction and provide a low frequency traditional air raid sound.
Single ended GP & FP siren coverage (GP6, FP6, GP10 & FP10)
Main Features
FP6 Siren
■
Audibility range between 106db @ 30metres for the smallest unit to 121db @ 30metres for the largest unit. Sirens in this range in 345
increasing order of sound output are the FP6 & FP10 units.
■
475Hz constant tone signal.
■
ATEX approved for zone 1 & 2.
■
Overall siren standard approval Exd IIG IIC T4.
■
Non electrical parts standard approval EExc IIC T1..T6 X.
■
Roughly omni-directional sound coverage which peaks in the
■
345
15
0
15
330
30
330
30
315
45
315
45
140 300
130
285
300
60
135
60
285
75
75
125
400Vac +/- 10% 50Hz 3 phase nominal power supply requirement. (Alternative voltages and frequencies available on request).
FP10 Siren
0
150 145
direction of the front of the stator.
■
Double ended GP & FP siren coverage (GP12)
270
270
90
120
Operating temperature range for the GP6 & GP10 units of -20 to
■
Cast aluminium & steel construction.
■
Environmental rating of IP55.
■
If the power supply to the sirens is pulsed to enable the siren to
255
105
255
+40 degrees C.
120
225
135
225
105
240
120
240
90
135
produce a ‘wail’ tone then the maximum run time of the siren is
■
195
Custom built control units can be supplied to enable the siren
210
150
210
reduced from continuous for constant tone to 15 minutes or less.
180
150 195
165
to produce the ‘wail’ tone signal and associated controls. The
180
165
GP6 & FP6 Siren
controls are only suitable for locating in a non-hazardous area.
GP10 & FP10 Siren
Sound Attenuation Chart Numeric Information
8
Model Audibility (db)
Configuration Omni-Directional
30
100
200
400
O
106
90
80
70
GP10/FP10
O
121
103
93
83
73
GP12
O
124
107
97
97
77
Siren Type
Motor Power
Current Rating
Weight
Dimensions: Overall Length Width & Height
Dimensions: Rotor Diameter
GP6/FP6
FP6
2.2kw
4.5A
68kg
490 x 394 x 437mm
400mm
FP10
5.5kw
13A
80kg
614 x 490 x 555mm
500mm
Call to order: +44 (0)161 287 5555
Distance from Siren (Metres) 800
1000
1500
74
67
Visit us at: www.klaxsonsignals.com
9
Electronic Sirens
Electronic Sirens – Superior Range
ES Siren Superior The ES siren superior range provides a sophisticated, robust and resilient solution to address wide area mass alert signalling for all industrial, civil, commercial and environmental requirements. The products are of modular construction incorporating an extremely flexible user configuration software package which allows the sirens to be scaled and tailored to the user’s most complex specific needs including omni or uni – directional sound coverage.
Main Features ■
Audibility range between 106db @ 30metres for the
■
smallest unit to 127db @ 30metres for the largest unit.
well as the standard horns for hazardous area operations
Sirens in this range in increasing order of sound output are the ES1/2S, ES1/3S, ES2S, ES3S and ES4S units.
■
16 user selectable & configurable emergency signals.
■
Storage for up to & selectable 400 pre-recorded voice messages. (Voice files are stored as PCM-CCITT 8 kHz 8
and mass coverage within a building.
■
Live PA via a 600 ohm balanced & isolated input.
■
Battery operated from an integral battery pack to
Active alarm signal or PA output via a set of N/O & N/C relay contacts for control of and supplementary devices. (i.e. Strobe beacon).
■
bits mono).
■
Option of driving 100V line driver horns in stead of or as
Four configurable VFC opto-coupled monitor inputs. (i.e. AC Power, Cabinet door open etc).
■
Four configurable relays with changeover contacts used to monitor the activities of the unit.
overcome AC power failure.
■
Siren activity and fault report log.
■
User definable schedules for time/date signalling.
■
Minimum alarm signal operating time of at least 6 minutes
■
Silent test facility to minimise nuisance signalling to test the siren.
■
■
standard or stainless steel on request, (800 x 600 x
Simple control and fault reporting via 8 VFC
250mm), which provides an environmental rating of IP65
Supports a radio & modem for remote operation via
and the siren horns are manufactured of cast aluminium.
■
Supports a GPS clock for accurate time synchronisation
Power supplied by an integral 48Vdc battery pack and an 88-132/176-264Vac @ 47–63Hz power source.
bi-directional integrated RS232 interface.
■
Control cabinet constructed from coated steel as
from the siren.
opto-coupled inputs and relay output(s).
■
Supports CMC 4 optional engineer’s activation & supervision panel with microphone input facility.
Full control and fault diagnosis of a single or multiple units via an RS485 interface of up to 1.5km distance
■
after a 7 day AC power loss.
■
■
Operating temperature range of -20 to +60 degrees C.
for schedules via an integrated RS232 interface.
■
Class D 375W amplifier used in the output with self healing short circuit, thermal & over current protection.
10
Call to order: +44 (0)161 287 5555
Visit us at: www.klaxsonsignals.com
11
Electronic Sirens – Superior Range – HMI Interfaces
SIP-51 HMII
CMC-4 HMI
CMC-8 HMI
TALOS 20 HMI Software for PC
The basic switch & indicator HMI unit provides a means of
The CMC-4 HMI unit provides a means of siren control
The CMC-8 HMI unit provides a means of siren control and
The software which operates under Microsoft windows
siren control and basic supervision for a single or multiple
and supervision for a single or multiple superior range siren
supervision for a multiple superior range siren system where the
allows the means of control and supervision required for
superior range siren system.
system via its RS485 communication interface.
use of a PC is not appropriate for the environment or where simple
a complex multiple superior range siren system.
■ ■
Activation of up to 5 alarm signals or pre-recorded messages and silent test.
■
Silent test result displayed on a single indicator
■
beacon which has been connected to a programmed relay output to indicate the state of the
Control of up to 4 alarm signals & 4 pre-recorded
activation switches next to the control unit are also required.
messages via its keypad and integral 2 line 16
■
Control of up to 16 alarm signals & 400 pre-recorded messages.
character LCD backlit module.
■
Microphone input connector for live voice or record & play
Microphone input connector for live voice or record & play voice messages.
■
siren on its controller.
■
Silent test activation facility and results displayed via
■
Control of up to 16 alarm signals & 400 pre-recorded messages.
voice messages.
■
Live voice control facility.
Silent test activation facility and results displayed via it multiple
■
Silent test activation facility and result display.
line LCD module.
■
User definable legends.
its LCD module.
■
User definable legends.
■
Master volume control.
■
Smaller units available with less switches/beacons.
■
Power for the unit is provided by the RS485 interface.
■
Master volume control.
■
User definable siren group allocation.
■
Environmental rating of IP65.
■
Magnetic coded switch to enable signal and voice
■
User definable siren group allocation.
■
Event & test logs to file or printer.
activation functions.
■
Event & test logs interface to a printer.
May be linked via a bi-directional radio link to the
■
Up to 8 programmable VFC inputs.
siren controller instead of a hardwire link.
■
Suitable for wall or desk mounting.
Can be located in the siren control panel or on a
■
All configuration information stored in non-volatile memory.
■
Magnetic coded switch to enable signal and voice
■ ■
convenient wall location.
■
All configuration information is stored in non-volatile memory.
activation functions.
■
May be linked via a bi-directional radio link to the siren controller instead of a hardwire link.
12
Call to order: +44 (0)161 287 5555
Visit us at: www.klaxsonsignals.com
13
Electronic Sirens – Superior Range – Radio Control
Radio and Control Equipment
Control Station: ■
Siren radio communication equipment:
Workstation. Pentium 400MHz 64 bit processor, keyboard, mouse, and CD Rom drive.
Motorola GM340 Databox. Transceiver. Operating frequencies
■
17 inch touch screen.
VHF 136-174 MHz, or UHF 403-470 MHz.
■
UPS 30 minutes.
■
Antenna. 3-Element YAGI.
■
Printer: Dot Matrix – Sheet Feeder.
■
TK401 Data Modem 1200-4800 bps.
■
Desk microphone.
■
Cables and installation accessories.
■
Electronic Sirens – Value Range
Base station communication equipment: ■
Simplex transceiver for voice and DATA computer connection.
■
Operating frequencies VHF 136-174 MHz, or UHF 403-470 MHz.
■
RF power 1 to 25 W programmable.
■
RJ45 input for Motorola desktop Microphone (HMN-3000B) for
■ ■
live voice announcements.
ES Siren Value
External battery connection for continues operation when
The ES siren value range provides a robust economic solution to address wide area mass alert
AC failure.
signalling for all industrial, civil, commercial and environmental requirement users who previously
Integrated power supply 120W - 110/230VAC for continues
found conventional motor driven sirens acceptable for their needs but would like the advantages
operating and charging battery.
of battery operation and no 400Vac cabling.
■
TK401 Radio-modem 1200 - 4800 Bps Transparent Mode.
■
2U 19” Rack Mountable Cabinet, with temperature control
The products are of modular construction which allows the sirens to be scaled and tailored to the user’s specific needs in terms of signalling and omni or uni – directional sound coverage.
fan (Wall mounting cabinet optional).
■
Antenna VHF (3DB) or UHF (5 DB) Collinear.
■
30 m coaxial antenna feeder.
Main Features ■
14
Configuration Omni or Uni Directional
ES1/2 S
Distance from Siren (Metres) 30
100
200
400
800
O
106
90
80
70
ES1/3 S
U
115
98
88
78
68
ES2 S
O
115
98
88
78
68
ES2 S
U
118
100
90
80
70
1000
(i.e. Strobe beacon).
■
Live PA via a 600 ohm balanced & isolated input.
■
Battery operated from an integral battery pack to overcome AC power failure.
■
■
input facility.
■
O
121
103
93
83
73
ES3 S
U
124
107
97
87
77
74
67
ES4 S
O
124
107
97
87
77
74
67
ES4 S
U
127
110
100
90
80
77
70
Minimum alarm signal operating time of at least 6 minutes after a 4 day AC power loss.
■
Control cabinet constructed from coated steel as standard or stainless steel on request, (600 x 400 x
interface of up to 1.5km distance from the siren.
200mm), which provides an environmental rating of IP65 and the siren horns are manufactured of cast aluminium
Simple control and fault reporting via 5 VFC
■
Supports a radio & modem for remote operation via an
Power supplied by an integral 48Vdc battery pack and an 88-132/176-264Vac @ 47–63Hz power source.
plus siren fault and AC power relay outputs.
■
Supports DT11 activation panel with microphone
Full control of a single or multiple units via an RS485
opto-coupled inputs, (Up to 4 alarm signals and PA)
ES3 S
Call to order: +44 (0)161 287 5555
relay contacts for control of and supplementary devices.
4 user selectable & configurable emergency signals.
■
Active alarm signal or PA output via a set of N/O & N/C
Sirens in this range in increasing order of sound output are
■
1500
■
smallest unit to 118db @ 30metres for the largest unit. the ES1/2V, ES1/3V and ES2V units.
Sound Coverage Chart Siren Model Audibility (db)
Audibility range between 106db @ 30metres for the
■
Operating temperature range of -20 to +60 degrees C.
integrated RS232 interface.
■
Class D 375W amplifier used in the output with self healing short circuit, thermal & over current protection.
Visit us at: www.klaxsonsignals.com
15
Electronic Sirens – Value Range – HMI Interfaces
Electronic Sirens – Value Range – Radio Control
Radio and Control Equipment
Control Station:
Siren radio communication equipment: ■
■
DT11 HMI.
■
Desk microphone.
Motorola GM340 Databox. Transceiver. Operating frequencies VHF 136-174 MHz, or UHF 403-470 MHz.
SIP-51 HMI
DT-11 HMI
The basic switch & indicator HMI unit provides a means of siren
The DT-11 HMI unit provides a means of siren activation and
control and basic supervision for a single or multiple value range
live voice input for a single or multiple value range siren
siren system.
system via its RS485 communication interface.
■
Activation of up to 4 alarm signals.
■
Test result displayed on a single indicator beacon which has
its keypad and integral 2 line 16 character LCD
been connected to the siren fault output relay.
backlit module.
■
■
Smaller units available with less switches/beacons.
■
■
Environmental rating of IP65.
■
Activation for up to 4 alarm signals or live PA via
■
Antenna. 3-Element YAGI.
■
TK401 Data Modem 1200-4800 bps.
■
Cables and installation accessories.
Base station communication equipment: ■
Simplex transceiver for voice and DATA computer connection.
■
Operating frequencies VHF 136-174 MHz, or UHF 403-470 MHz.
■
RF power 1 to 25 W programmable.
■
RJ45 input for Motorola desktop Microphone (HMN-3000B) for live voice announcements.
Microphone input connector for live voice. Power for the unit is provided by the RS485 interface or
■
AC failure.
via the units 12Vdc input connector, if there is to great a volt drop or used in conjunction with a radio link.
■ ■
■
Can be located in the siren control panel or on a
■
TK401 Radio-modem 1200 - 4800 Bps Transparent Mode.
■
2U 19” Rack Mountable Cabinet, with temperature control fan (Wall mounting cabinet optional).
convenient wall location.
■
All configuration information is stored in non-volatile memory.
Integrated power supply 120W - 110/230VAC for continues operating and charging battery.
May be linked via a uni-directional radio link to the siren controller instead of a hardwire link.
External battery connection for continues operation when
■
Antenna VHF (3DB) or UHF (5 DB) Collinear.
■
30 m coaxial antenna feeder.
Sound Coverage Chart
16
Call to order: +44 (0)161 287 5555
Siren Model Audibility (db)
Configuration Omni or Uni Directional
ES1/2 V
Distance from Siren (Metres) 30
100
200
400
800
O
106
90
80
70
ES1/3 V
U
115
98
88
78
68
ES2 V
O
115
98
88
78
68
ES2 V
U
118
100
90
80
70
1000
1500
Visit us at: www.klaxsonsignals.com
17
Electronic Sirens – Portable
ES Siren Superior Portable
ES Siren Value Portable
Main Features
The ES siren superior portable range provides an
The ES siren value portable range provides an
■
extremely robust and sophisticated rapidly deployable e
extremely robust and rapidly deployable wide
to 115db @ 30metres for the largest unit. Sirens in this range in
wide area warning device with its own integral
area warning device with its own integral battery
increasing order of sound output are the ES1/2VP, ES1/3VP units
battery pack making it ideally suitable for emergency y
pack making it ideally suitable for emergency
■
4 user selectable & configurable emergency signals.
and civil defence operation, quarrying, open cast
and civil defence operation, quarrying, open cast
■
Live PA via a 600 ohm balanced & isolated input.
mining, railway maintenance and many other mass
mining, railway maintenance and many other mass
■
Battery operated from an integral battery pack housed in its own
notification applications.
notification applications.
Audibility range between 106db @ 30metres for the smallest unit
container for rapid replacement in operational conditions.
■ The products are based on the standard superior
The products are based on the standard value
range of siren which allows the sirens to be scaled
range of siren which allows the sirens to be scaled
and tailored to the user’s specific needs in terms
and tailored to the user’s specific needs in terms
of signalling and omni or uni – directional
of alarm signalling and omni or uni – directional
sound coverage.
sound coverage.
Full control of a single or multiple units via an RS485 interface of up to 1.5km distance from the siren.
■
Simple control and fault reporting via 5 VFC opto-coupled inputs, (Up to 4 alarm signals and PA) plus siren fault and AC power relay outputs. (3 inputs connected to buttons on the enclosure).
■
Supports a radio & modem for remote operation via an integrated RS232 interface.
■
Class D 375W amplifier used in the output with self healing short circuit, thermal & over current protection.
■
Main Features ■
contacts for control of and supplementary devices.
Audibility range between 106db @ 30metres for the smallest
■
Auxiliary monitor & control inputs & outputs.
unit to 115db @ 30metres for the largest unit. Sirens in this
■
Siren activity and fault report log.
range in increasing order of sound output are the ES1/2SP
■
Operation run time when emitting a continuous sound
(i.e. Strobe beacon).
■
Operation run time when emitting a continuous sound or message is approximately 1 hour from a fully charged battery pack.
and ES1/3SP.
or message is approximately 1 hour from a fully charged
■
Supports DT11 activation panel with microphone input facility.
■
16 user selectable & configurable emergency signals.
battery pack.
■
Control and battery enclosures constructed from die cast
■
Storage for up to & selectable 200 pre-recorded voice
Supports CMC 4 optional engineer’s activation & supervision
aluminium and fitted with fully weatherproof Mil-Standard
panel with microphone input facility.
connectors which provide an environmental rating of IP65. The
Control and battery enclosures constructed from die cast
battery enclosure also contains an integrated charger for ease
Live PA via a 600 ohm balanced & isolated input & record
aluminium and fitted with fully weatherproof Mil-Standard
of maintenance. (Enclosure sizes & weight 420x300x230mm, 9Kg
playback facility to avoid acoustic feedback.
connectors which provide an environmental rating of
control unit & 26Kg battery unit).
Battery operated from an integral battery pack
IP65. The battery enclosure also contains an integrated
housed in its own container for rapid replacement
charger for ease of maintenance. (Enclosure sizes & weight
■
messages. (Voice files are stored as PCM-CCITT 8000 kHz 8 bits mono).
■ ■
■
in operational conditions.
■
User definable schedules for time/date signalling.
■
Silent test facility to minimise nuisance signalling to test the siren.
■ ■
Full control and fault diagnosis of a single or multiple units via
schedules via an integrated RS232 interface.
■
■
Siren deployable by two personnel.
■
Battery pack would be recharged from a suitable 230Vac supply
Class D 375W amplifier used in the output with self healing short circuit, thermal & over current protection.
and would take in the region of 8 hours when charged from a fully
■
■
discharged state.
Siren deployable by two personnel.
■
Battery pack would be recharged from a suitable 230Vac charged from a fully discharged state.
Supports a GPS clock for accurate time synchronisation for
loudspeaker horns.
loudspeaker horns.
■
Operating temperature range of -20 to +60 degrees C.
Operating temperature range of -20 to +60 degrees C.
Sound Coverage Chart Siren Model Audibility (db) ES1/2 SP ES1/2 VP ES1/3 SP ES1/3 VP
Call to order: +44 (0)161 287 5555
Hydraulic 4 metre high telescopic mast fitted with IP65 rated
Hydraulic 4 metre high telescopic mast fitted with IP65 rated
supply and would take in the region of 8 hours when
Supports a radio & modem for remote operation via
■
420x300x230mm, 9Kg control unit & 26Kg battery unit).
Simple control and fault reporting via 8 VFC opto-coupled
bi-directional integrated RS232 interface.
■
■
an RS485 interface of up to 1.5km distance from the siren.
inputs. (3 connected to buttons on the enclosure).
■
18
Active alarm signal or PA output via a set of N/O & N/C relay
Configuration Omni or Uni Directional
Distance from Siren (Metres) 30
100
200
400
O
106
90
80
70
U
115
98
88
78
800
1000
1500
68
Visit us at: www.klaxsonsignals.com
19
Electronic Sirens – Sound Coverage
Electronic Sirens – Control Options
Sound Coverage The ES range of sirens can be configured for omni- or uni-directional sound coverage. Below are typical sound coverage plots in clear still air on level terrain with no obstructions. Microphone Microphone
Uni-directional Configuration This horn has the narrow - rectangular shape
Simple control box containing voltage free switches and a fault indicator beacon.
Prime direction
to provide a specific SPL at ±90˚ to the prime direction of radiation.
VFC Interface Microphone
6dB difference in SPL (Half the SPL)
±90˚ to the prime direction
CMC-4 Activation & Integration panel with live voice option. (Can be mounted in siren control panel)
CMC-8 Master control Panel with supplementary VFC activation switch plus live voice & log printer options. Master control PC running Talos 20 software with live voice & log printer options. RS485 Interface
VFC Interface
Omni-directional Configuration
Antenna
Either or interface to siren(s). Direct RS485 or via radio link.
SBD-VHF or SBD-UHF Radio Base Station Antenna
This siren has 2xRS485 interfaces of which the radio talks one if used and 8 VFC interfaces so multiply control routes can be accommodated.
20
Call to order: +44 (0)161 287 5555
CS Siren Controller (Single or Multiple units)
Optional number of 100V line driven speakers which may be ATEX approved for hazardous zoned areas.
Visit us at: www.klaxsonsignals.com
21
Features Comparison Chart
Comparing Superior and Value Electronic Sirens Compared Feature
Superior Siren Type
Value Siren Type
2 - 18
2-6
106 - 124 Omni -directional
106 - 115 Omni -directional
112 - 127 Uni -directional
112 - 118 Uni -directional
Stored Alarm Signals
16
4
Stored Pre-recorded Messages
200 - 400
-
Live PA
Yes
Yes
PS485 Communication Interface
2
1
Programmable Control Inputs (VFC)
8
-
Control Inputs (VFC)
-
4 + 1 for PA
Programmable Monitor Inputs (VFC)
4
-
Programmable Control Outputs (VFC)
4
-
Siren Operating Outputs (VFC)
2
2
Programmable Silent Test Feature
Yes
-
Siren Sounded Correctly Output (VFC)
-
Yes
Internal & External Fault & Event Logging
Yes
-
Programmable Event Scheduler
2
-
Hardware Control Modules
SIP-51, CMC-4, CMC-8
SIP-51, DT-11
PC Software Control Modules
Talos 20
-
AC Power
230 Vac 10A
230 Vac 10A
Battery Quantity
4
4
Battery Capacity
44Ah (Greater for 18 horn unit)
18Ah
1. Output Capacity Number of Horns Audibility at 30 metres 2. Signal Capacity
3. Interfaces
4. Test Facility
5. Event Logging/Scheduling
6. HMI Equipment
7. Power
8. Build Control Cabinet Size Environmental Rating
800 x 600 x 250mm (Larger cabinet or 2 cabinets for 18 horn unit)
600 x 400 x 200mm
IP65
IP65
2 way
1 way
1
-
9. Build FM narrow band radio VFH (136 - 174Mhz) or UHF (400 - 470Hz) or licence free GSM Clock
22
Call to order: +44 (0)161 287 5555
Visit us at: www.klaxsonsignals.com
23
Klaxon Signals Ltd Wrigley Street, Oldham, Lancashire, OL4 1HW Tel: +44 (0) 161 287 5555 Fax: +44 (0) 161 287 5511 Email:
[email protected] Web: www.klaxonsignals.com
Issue Number 100A