Pompy ciep³a niskotemperaturowe DERON EVI ( do 25℃)
Description Compact air/water heat pump for outside installation. With suction EVI technologies gas cooled scroll compressor. Emerson expansion valve Saginomiya 4way valve. With extensive aluminium/Cu lamellar tube evaporator and coaxial condenser. Axial fan Refrigerant cycle with thermostatic expansion valve, filter, gasliquid seperator, high and low pressure switches. With efficient automatic defrosting by hot gas principle. Electric and terminal box. With control and Disturbance signalling. Heating regulator for mounting to the wall. Filled with refrigerant R417a. Water connections Water connections have to be done on site. Heating and condensate connections of flexible pipes with external thread (R). Condensate connection The drain pipeline is to be made with sufficient incline and without change of the crosssection. The water connections and the drain pipelines must be protected against frost on site. Siphon on site. Heat source connections (Air intake or air outlet) Air intake from the sides. Air outlet on the top. Electrical connections Connection from the bottom to the left or to the right. Installation Variable and costefficient installation possibilities. Delivery Complete, packed
DERON EVI low ambient temp.(25℃) Air/Water Heat Pump For Hot water/Heating Technical datas: Model
DE27W/CW
DE46W/CW
DE92W/DW
DE180W/DW
Power supply (V/ph/Hz) 220/1/50 380/3/50 380/3/50 380/3/50 ☆Heating capacity(kW) 11.6 19.8 39.5 81 ☆Rated power input (kW) 2.7 4.6 9.2 18 Water feed speed (L/h) 250 425 850 1665 ☆☆Heating capacity(kW) 6 10.2 20.5 40.3 ☆☆Rated power input (kW) 2.5 4.3 8.5 16.8 Water feed speed (L/h) 129 219 440 866 ☆☆☆Heating capacity(kW) 4.6 7.9 15.8 31 ☆☆☆Rated power input (kW) 2.6 4.4 8.8 17.2 Water feed speed (L/h) 98 170 340 666 Refrigerant R417A Refrigerant weight (g) 2000 2500 2500*2 2500*4 Max. current (A) 18.5 13 25 49 Rated water temp. (℃) 55 55 55 55 Max. water temp. (℃) 60 60 60 60 Level against electric shock I I I I Waterproof grade IPX4 IPX4 IPX4 IPX4 Net weight (Kg) 130 175 320 680 Net size (mm) 800X700X1000 800X700X1150 1200X920X1455 2400X1130X2300 Required water flow rate (m3/h) 2.2 4 8 16 Recommended tank cubage (t) 23 35 710 15 Test condition 20 Water connection G1" G1" G11/4" G2" Operation temp. range (℃) 2545 2545 2545 25 45 Range of Application Noise dB (A) ≤55 ≤60 ≤65 ≤68
Ambient temperature
°C
25 45
Max. Water temperature
°C
60
☆ Parameters1 test conditions:*Heating: Ambient temp.(DB/WB): 20℃ /15℃, Water temp.(Initial/Final): 15℃/55℃. ☆☆ Parameters1 test conditions:*Heating: Ambient temp.(DB/WB): 15℃, Water temp.(Initial/Final): 15℃/55℃. ☆☆☆Parameters1 test conditions:*Heating: Ambient temp.(DB/WB): 25℃, Water temp.(Initial/Final): 15℃/55℃.
DERON EVI low ambient temp.(25℃) Air/Water Heat Pump For Hot water/Heating DE46W/CW Dimension(mm):
1.Condensing water output 2.Heating Water output 3.Heating Water input 4.Wiring cable connecting 6.Door lock 7.Wiring box 8.Air intake 9.Air outlet.
DERON EVI low ambient temp.(25℃) Air/Water Heat Pump For Hot water/Heating Installation The following boundary conditions must be kept: l The installation place should be selected in such a way that air intake and outlet is not hampered or obstructed leaves etc. l There should be provided sufficient space for intake and outlet as well as for operation and maintenance. l Air shortcircuit must be avoided. The space necessary for intake and outlet must be always provided. l Intake air must be completely free from aggressive substances like ammonia,sulphur,chlorine etc. l The installation place should not be situated under living rooms or bedrooms because of sound emission and be placed at sufficient distance from the neighbouring building. l Is not recommended to install the heat pump into wall niches(air shortcircuit,sound echo) l The heat pump must not be installed in a trough(in the terrain or building) Air intake and outlet Take particular account of the sound emissions.Local presciptions must be obervied. Condensate pipeline Condensate must be able to run off freely(frost pretected drain.).The condensate drain must be provided onsite with an airtight siphon of minimum height 100mm. Wall lead through Wall lead through for pipelines must be implemented and sealed by technicians. Electric connections l Electric connection cables must be short, connected flexibly and be rounted by technicians and according to local prescription. l
Where trace heating tapes for the condensate drain and the flow and return lines are used,they must be connected externally in accordance with applicable regulations and additionally protected by a ground fault circuit interrupter.
¨ Installation of Storage Hot Water Tank ● Storage hot water tank can be installed on the balcony, roof or ground with the outdoor unit. It can also be installed indoor. ● ● ● ●
The tank must be vertically installed to the ground. The tank must stand with pads under its feet. (The thickness of the pad should be ≥10cm). Heat Pump installation must be made easy. The tank shall not be hung on the wall. www.asat.na.allegro.pl www.asat.pl Tel.+4832 2654112
DERON EVI low ambient temp.(25℃) Air/Water Heat Pump For Hot water/Heating ● The framework for outdoor unit mounting should be secure and reliable installed. See the Diagram (only for reference) Stop valve, Yfilter and check valve must be installed to the water feed pipe before water enters into the tank. ● Flexible pipe should be fixed to the relief valve for hot water, to release the pressure. ● Dirty water should be leaded to the floor drain through a flexible pipe, before that, stop valve must be installed to the pipe.
Commissioning must be made by work service or Deron trained service man/company www.deron.com.pl +48 32 2654112 www.asat.pl www.asat.na allegro.pl