Ventilation Solutions Product Guide 2011

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 1 THE VENTILATION SPECIALISTS Ventilation Solutions Product Guide 2011 L S L AIR MO...
Author: Owen Williamson
53 downloads 0 Views 9MB Size
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 1

THE VENTILATION SPECIALISTS

Ventilation Solutions Product Guide 2011

L

S

L

AIR MOVEM EN

INDUST

RIA

SYST

EM

COMMER CIA

DOME ST I

C

T

Edition 2

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 2

BRANDS

2

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 3

INTRODUCTION

Welcome to TVS TVS was formed in 2011 to provide a comprehensive range of ventilation products from many leading brands covering domestic, commercial, industrial, and air movement applications. We are part of a larger national distribution organisation, with over 15 years experience in designing, specifying, and supplying ventilation solutions throughout the Australian marketplace. Our new range includes products from European market-leading brands Blauberg, Greenwood and Xpelair. These brands are known for their reliability and evolving technology, which will ensure TVS leads the way as “your ventilation solutions provider”. Coupled with products already available from Revelair and Airware, we have chosen our new portfolio specifically to meet the expectations of the Australian marketplace. As reliability is a critical factor in fan performance all TVS fans have been selected with ball bearing motors. A ball bearing motor will ensure our fans perform consistently for a number of years. As a result we support all exhaust fans with a 2 - 5 year replacement warranty. Within the range there are a wide variety of installation solutions, from ceiling, window, and wall-mounted fans, to complete in-duct ventilation solutions which will meet the most demanding array of applications. You can choose from a Classic model which offers high performance, or one of our superior specification models like the Bravo which are designed to be used in harsher and more demanding environments. These higher end models also offer faster and easier installation for the contractor. For a modern look within the home, we offer a range of designer models including the Quatro, Art, Lux, Ice and Glory just to name a few. These will offer the consumer stylish visual appeal to match current trends in bathroom decor. TVS has a ventilation product for every application. Continual development and innovation will ensure that future market demands are not only met but exceeded.

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

3

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 4

THE RANGE

4

QUATRO

ART

LUX

ICE

GLORY

AUTO

ECO

150mm SERIES

WX SERIES

AERO

AERO STILL

BRAVO

BRAVO STILL

BRISE

100mm SERIES

HEADER BOX FAN

AERO KIT

BRAVO KIT

WIND

HEAT 'n VENT

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.repelec.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 5

THE RANGE

IN-LINE FAN

XIL SERIES

TUBO

TURBO M

GRILLES

ROUND DIFFUSERS

DUCTING

GX SERIES

XIDP SERIES

WH SERIES

COMING SOON

COMING SOON

COMING SOON

COMING SOON

COMING SOON

COMING SOON

COMING SOON

COMING SOON

COMING SOON

WALL & PEDESTAL FANS

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.repelec.com.au

5

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 6

CONTENTS

DOMESTIC WALL FANS Quatro ........................................................................................................................................................14-15 Art ..............................................................................................................................................................16-17 Lux ..............................................................................................................................................................18-19 Ice ..............................................................................................................................................................20-21 Glory ..........................................................................................................................................................22-23 Auto............................................................................................................................................................24-25 Eco ..............................................................................................................................................................26-27 150mm Series ............................................................................................................................................28-29 WALL /CEILING FANS Aero............................................................................................................................................................32-33 Aero Still ....................................................................................................................................................34-35 Bravo ..........................................................................................................................................................36-37 Bravo Still ..................................................................................................................................................38-39 Brise............................................................................................................................................................40-41 DX Series ....................................................................................................................................................42-43 HEADER BOX FAN Header Box Fan ........................................................................................................................................44-45 Header Box Fan Kit....................................................................................................................................44-45 THRU WALL FANS Aero Kit ......................................................................................................................................................46-47 Bravo Kit ....................................................................................................................................................48-49 WINDOW FANS Wind ..........................................................................................................................................................50-51 HEAT ‘n VENT 2 Light ........................................................................................................................................................52-53 4 Light ........................................................................................................................................................52-53 SHOWER FAN KITS Turbo 125 Kit ............................................................................................................................................54-55 Turbo 150 Kit ............................................................................................................................................54-55 IN-LINE FANS XIL Series....................................................................................................................................................56-57 Turbo ..........................................................................................................................................................58-59 Turbo M ......................................................................................................................................................60-61

6

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 7

CONTENTS

GRILLES Fixed ..........................................................................................................................................................62-63 Gravity........................................................................................................................................................62-63 Eggcrate ....................................................................................................................................................62-63 Round Diffuser ................................................................................................................................................64 DUCTING PVC ..................................................................................................................................................................65 Aluminium Flexible ........................................................................................................................................65 Aluminium Semi Rigid ....................................................................................................................................65 COMMERCIAL WINDOW / WALL FANS GXC Series..................................................................................................................................................66-67 GX Series ....................................................................................................................................................68-69 IN-LINE FANS XIDP Series ................................................................................................................................................70-71 WALL HEATER FANS WH Series ..................................................................................................................................................72-73 INDUSTRIAL

SYSTEMS

AIR MOVEMENT Wall Fan ....................................................................................................................................................78-79 Pedestal Fan ..............................................................................................................................................78-79

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

7

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 8

VENTILATION SELECTION • It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Use ducted fans, through-wall fans or window fans at all times. Do NOT use ceiling fans which discharge into the ceiling cavity - this only moves the problem. Moisture will permeate insulation and ceiling linings causing further problems. • In particular with bathrooms think in terms of “roomconditioning”. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel. Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation.

Window open ai

Fan Placement Careful location of an extraction fan will ensure maximum airflow through the room. Air extracted from a bathroom, for example, can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door. This ensures that fresh air is being drawn into the entire house at regular periods.

Use a door vent if necessary. For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room e.g. air in = air out

la

n tio

POOR CIRCULATION

on

Window closed

ti

Switching the fan on before starting showering or cooking sets up effective air-flows before the associated condensation problems occur. Closing doors to adjacent living areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door to replace extracted air.

i r c

u rc

ai

r

r ci

cu

la

MEDIUM CIRCULATION

Window closed

n atio cul r i c air

BEST CIRCULATION An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at the bottom), you may need to fit a through-door grille (see duct accessories) to allow replacement air into the room.

8

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 9

FAN REGULATIONS What the law states AS1668 (summarised): “...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces; poisonous or flammable fumes and gases...” Australian Building Code Paragraph 3.8.5.0 states: Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS 1668.2. “Mechanical ventilation for acceptable indoor air quality”, except that any contaminated air from a sanitary compartment or bathroom must: (a) Exhaust directly to outside the building by way of ducts; or (b) Exhaust into the roof space provided: i.

It is adequately ventilated by open eaves, and/or roof vents; or ii. The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles. As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents. The TVS range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the latest building code. Natural ventilation for the above is acceptable as long as opening windows in each room have an area of 5% or more of the floor area of the room.

Bathrooms The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed

Toilets The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed

Kitchens The regulations require a fan capable of a minimum extraction capacity of 50 litres per second when installed

Laundries The regulations require a fan capable of a minimum extraction capacity of 20 litres per second when installed

LEGEND ● Pull-Cord Switch ● Timer ● Humidity Sensor

Motion Sensor ● Fixed ● Gravity ● Eggcrate ● PVC ● Aluminium Flexible ● Aluminium Semi Rigid

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

9

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 10

CIRCULATING FAN PERFORMANCE

1. Litres/Second (l/s)

4. Working out the right fan for the job

milk 1 litre

1. Calculate the room volume in metres (L x W x H) 2. Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit. 3. The result is the total performance required in cubic metres per hour.

1m 1m

2. Cubic Metres/Hour (m3/hr)

1m

To convert from one to other types of measurement:

For Example: What is the best fan for a bathroom that is 2.8m long by 2.8m wide with a ceiling height of 2.4m?

If you know Litres/Second (l/s): l/s x 3.6 = m3/hr. (e.g. 25 l/s x 3.6 = 90m3/hr)

1. Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4 = 18.8m3

If you know Cubic Metres/Hour (m3/hr): m3/hr ÷ 3.6 = l/s (e.g. 200m3/hr ÷ 3.6 = 55.55 l/s

2 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m3/hr.

3. ACH (Air changes per hour). The number of times the total room volume of air is changed each hour.

Refer to the table below for the recommended Air Changes per hour based on the room type. Application Description

Air Changes Per Hour

Bathrooms

11 - 15

Kitchens - (private)

15 - 20

Laundries - (no drier)

6 - 10

Laundries - (with drier) Toilets

10 - 30 6 - 10

Bedroom

2-5

Offices

Select a fan with a higher performance than this figure

3. The fan to choose for this bathroom would be a fan that performs at greater than 282m3/hr. A fan that has a performance level of 313m3/hr or higher (eg. BRAVO150, or TURBO150KIT) would do this job. 5. Converting measurements Quick Cross-Reference Calculations Known To Find Action l/s m3/hr cfm cfm

m3/hr l/s m3/hr l/s

m3/hr to l/s to cfm Comparison Chart

10 - 12

Canteens

8 - 12

Garages

6-8

Kitchens - (commercial)

240

110

400

6 - 10

Cafés

l/s x 3.6 =m3/hr m3/hr ÷ 3.6 = l/s cfm x 1.69 =m3/hr cfm x 0.47 = l/s

220

100 350

200

90 300

180

80

160 70

250

140

20 - 30

60 120

200

Restaurants

8 - 12

Factories

8 - 10

Stores & Warehouses

3-6

Libraries

3-5

50 100 150

40

80

30

100

60

20

40

10

20

50

Classroom

5-7 0

10

m3/hr

l/s

cfm

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 11

WHAT EFFECTS PERFORMANCE?

Simple facts: 1. Fan size (i.e diameter of impeller & outlet) 2. Duct and the way it is installed Smaller duct = greater resistance to airflow. More bends = greater resistance to airflow. Longer duct runs = increasingly reduced airflow. Wrinkled ducting causes turbulence and reduces airflow

Compare Centrifugal Against Axial Fan Performance: 1. Axial 100mm vs 100mm Centrifugal fan The starting point is the free air performance of 23l/s for the axial and 31l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases volume of air moved. From the below example you can see that at 20Pa of pressure the 100mm axial fan airflow has stopped whereas the 100mm centrifugal fan is still moving 29l/s!

Smoother, extended ducting allows smooth, increased airflow

REVELAIR ALUDUCT flexible ducting retains its stretched-out shape (for smooth airflow) far better than most competitive products. Many competitive ducts tend to shrink back on themselves, wrinkling the duct fabric. 3. Fan type Centrifugal Flow Pressure developing fans which achieve good flow against the resistance created in a ducted system. Particularly useful in venting areas like internal bathrooms / laundries, multi-room extraction systems, heat-transfer systems, etc.

2. Axial 150mm fan vs 150mm Centrifugal fan The starting point is the free air performance of 89l/s for the axial and 115l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases the volume of air moved. From the below example you can see that at 120Pa of pressure the 150mm axial fan airflow has stopped whereas the 150mm centrifugal fan is still moving 102l/s!

Mix Flow Powerful in-duct mounted fans, designed for applications that require high air flows, with low relative noise. Axial Flow Suitable for wall, window and roof applications where they can extract directly to the outside. Short duct runs are an option but the length of duct should be limited. e.g. 100mm dia : 2-3m length 125mm dia : 3-4m length 150mm dia : 4-5m length

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

11

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 12

FAN APPLICATIONS Locate your Ventilation Fan Location of your ventilation fan will depend on the physical constraints of your room. The visual recognition guide (shown on the right) will help you decide the most suitable physical installation to meet your requirements. Within the above mounting options there are various other features available, such as : • TIMER (maintain fan run-on after the room is vacated) • PULLCORD (Switch at fan, instead of light switch control) • AUTO-SHUTTER (electrically operated shutters inside the fan - closed when the fan is not running to stop draughts). • PIR SENSOR (provide automatic motion-sensor control of fans)

Low voltage Shower

Wall/Ceiling Mounted Fans Thru Wall Fan Kits In-Line Fan Kits

Window Fans Thru Roof Fan Kits Low Voltage Fans

Wet Areas & Recommended Fan Types When considering where in the room to place an extractor fan, you must consider the wet areas.

Zone 2: This zone is 0.6 metres horizontally outside of zone 1 and 2.25 metres above the floor

Outside Zones

Outside Zones 0.25m 2.4m

0.6m

0.6m

ZONE 2 2.25m

Zone 1: This is the zone directly within the shower or bath up to 2.25 metres above the floor and 150mm around the bath/shower cubicle. A SELV fan or an ln-line fan kit will be required in this zone. For example if a fan is mounted directly over the bath or shower it must be a low voltage fan (SELV).

ZONE 3

ZONE 1

ZONE 1

ZONE 2

2.4m

ZONE 3

150mm

2 3

Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally outside of zone 2 and 2.25 metres above the floor.

12

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 13

FAN APPLICATIONS EXAMPLES

Ceiling Mounted Fan: Designed for low-pitch roofs or between floors, where there is no ceiling access. This enables the fan to be accessible for service after installation. Also available with heat lamps & lighting.

Duct

Ceiling Fan

Fixed Grille

Thru Wall Fan Kit: Used where the bathroom is on an external wall, or there is no ceiling space for an in-line fan.

Duct Gravity Grille

Fan Motor

Window Fan

Fan Motor PVC Duct Fixed Grille

Window Mounted Fan: Used in situations where an existing window fan is being replaced, or where there is no available external wall space and no ceiling space access.

In-line Fan Kit: Most common bathroom installation, the fan is mounted in the ceiling space with the grille directly above the source of the steam. Generally this type of installation is quieter as the fan is not directly in the room.

Roof Cowl Kit Fan Motor PVC Duct Fixed Grille

Thru Roof Kit Used where there is limited access to the roof space, or where there is no soffit available. Thru Roof Kits can be used with any extraction fan, or use a Thru Roof Fan Kit with the fan mounted within the cowl.

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

13

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 14

DOMESTIC QUATRO

Quatro 100 Quatro 125 Quatro 150 Quatro Platinum ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑



Quatro Hi-tech

Quatro Chrome

Quatro Gold

Application Wall fan ■

For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - metallic (Quatro Platinum), aluminum (Quatro Hi-Tech), chrome (Quatro Chrome), gold (Quatro Gold) 5 years guarantee



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

Modifications Pull-cord switch

Part Number Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min

BLAQUATRO100 BLAQUATRO100S BLAQUATRO100T BLAQUATRO100ST BLAQUATRO100H BLAQUATRO100SH BLAQUATRO125 BLAQUATRO125S BLAQUATRO125T BLAQUATRO125ST BLAQUATRO125H BLAQUATRO125SH BLAQUATRO150 BLAQUATRO150S BLAQUATRO150T BLAQUATRO150ST BLAQUATRO150H BLAQUATRO150SH

Pull-cord switch

Timer

Humidity Sensor

● ●

● ● ● ●

● ● ●

● ● ● ●

● ● ● ●

● ● ● ●

Note: To order decorative option please add the following suffix after the part number: Metallic (QP), Aluminium (QHT), Chrome (QC), Gold (QG)

14

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 15

DOMESTIC



Overall and installation dimensions

Model Number QUATRO100 QUATRO125 QUATRO150



Dimensions mm b c d 151 108 100 178 113 125 207 165 150

a 171 201 236

e 32 35 38

Specifications

Quatro 100

Quatro 125

Quatro 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Extract capacity, m3/h

88

167

265

Noise level, dBA 3m

33

34

37

2300

2400

2400

Parameters Quatro 150 Quatro 125

Quatro 100



Safety regulations



Packing

r.p.m

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

15

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 16

DOMESTIC ART STEEL

Art 100 Art 125 Art 150

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions





Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Stainless steel front cover options 5 years guarantee



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

Part Number

Timer

Humidity Sensor

BLAART100 BLAART125 BLAART150

n/a n/a n/a

n/a n/a n/a

Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)

16

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 17

DOMESTIC



Overall and installation dimensions

Model Number ART100 ART125 ART150



a 180 204 230

e 49 55 53

Specifications

Parameters Art 150

Art 125

Art 100



Dimensions mm b c d 120 142 100 140 147 125 165 155 150

Art 100

Art 125

Art 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Extract capacity, m3/h

88

167

265

Noise level, dBA 3m

33

34

37

2300

2400

2400

r.p.m

Safety regulations

IP 34



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

17

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 18

DOMESTIC LUX STEEL

Lux 100 Lux 125 Lux 150

■ ❑ ■

Application Wall fan ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Ball bearing motor Stainless steel front cover options Built-in LED-Lamp (2 W) 5 years guarantee



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑ ❑

Timer

Part Number

Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min

18

BLALUX100 BLALUX100T BLALUX100H BLALUX125 BLALUX150

Timer

Humidity Sensor

● ●

Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 19

DOMESTIC



Overall and installation dimensions

Model Number LUX100 LUX100T LUX100H LUX125 LUX150



Dimensions mm b c d 120 143 100 122 151.6 98 122 151.6 98 140 152 125 165 169 150

a 180 183 183 204 230

e 49 65 65 55 53

Specifications

Parameters Lux 150

Lux 125 Lux 100

Lux 100

Lux 125

Lux 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Current, A

0.085

0.1

0.13

Extract capacity, m3/h

89

164

258

Noise level, dBA 3m

33

34

37

2300

2400

2400

r.p.m



Safety regulations



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

19

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 20

DOMESTIC ICE GLASS

Ice 100 Ice 125 Ice 150

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions





Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Ball bearing motor Glass front cover option 5 years guarantee



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑

Part Number

Timer

Humidity Sensor

BLAICE100 BLAICE125 BLAICE150

n/a n/a n/a

n/a n/a n/a

Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)

20

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 21

DOMESTIC



Overall and installation dimensions

Model Number ICE100 ICE125 ICE150



a 183 205 233

e 58 58 58

Specifications

Parameters Ice 150

Ice 125

Ice 100

Ice 100

Ice 125

Ice 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Current, A

0.085

0.1

0.19

Extract capacity, m3/h

105

185

298

Noise level, dBA 3m

37

38

40

2300

2400

2400

r.p.m



Dimensions mm b c d 120 151 100 140 156 125 165 173 150

Safety regulations

IP 34



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

21

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 22

DOMESTIC GLORY GLASS

Glory 100 Glory 125 Glory 150

■ ❑ ■

Application Wall fan ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Ball bearing motor Glass front cover options Built-in LED-Lamp (2W) 5 years guarantee



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑ ❑

Timer Part Number

Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min

22

BLAGLORY100 BLAGLORY100T BLAGLORY100H BLAGLORY125 BLAGLORY150

Timer

Humidity Sensor

● ●

Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 23

DOMESTIC



Overall and installation dimensions

Model Number GLORY100 GLORY100T GLORY100H GLORY125 GLORY150



a 180 183 183 204 230

e 49 65 65 55 53

Specifications

Parameters Glory 150 Glory 125

Glory 100

Glory 100

Glory 125

Glory 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Current, A

0.085

0.1

0.13

Extract capacity, m3/h

89

164

258

Noise level, dBA 3m

33

34

37

2300

2400

2400

r.p.m



Dimensions mm b c d 120 143 100 122 151.6 98 122 151.6 98 140 152 125 165 169 150

Safety regulations

IP 22



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

23

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 24

DOMESTIC AUTOMATIC SHUTTERS

Auto 100 Auto 125 Auto 150

■ ❑ ■

Application Wall fan ■



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Automatic shutters Ball bearing motor 5 years guarantee



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min

24

Part Number BLAAUTO100 BLAAUTO100S BLAAUTO100T BLAAUTO100ST BLAAUTO100H BLAAUTO100SH BLAAUTO100IR BLAAUTO125 BLAAUTO125S BLAAUTO125T BLAAUTO125ST BLAAUTO125H BLAAUTO125SH BLAAUTO125IR BLAAUTO150 BLAAUTO150S BLAAUTO150T BLAAUTO150ST BLAAUTO150H BLAAUTO150SH BLAAUTO150IR

Pull-cord switch

Timer

Humidity Sensor

Motion Sensor

● ●

● ● ● ●



● ●

● ● ● ●



● ● ●

● ● ● ●

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 25

DOMESTIC



Overall and installation dimensions

Model Number AUTO100 AUTO125 AUTO150



a 166 186 210

d 100 125 150

e 30 33 34

Specifications

Parameters Auto 150 Auto 125 Auto 100

Auto 100

Auto 125

Auto 150

Voltage,V

220-240

220-240

220-240

Power, W

18

22

26

Extract capacity, m3/h

89

185

295

Noise level, dBA 3m

34

35

39

2300

2400

2400

r.p.m



b1 150 128 150

Dimensions mm b2 b3 c 150 150 90 173 174 98 195 196 115

Safety regulations

IP 22



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

25

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 26

DOMESTIC ECO

Eco 100 Eco Platinum ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions

■ ❑

Automatic shutters

"open" position

26

"closed" position

Application Low energy consumption of the motor (6 W) elaborated by BLAUBERG engineers



Noiseless impeller’s blades resemble the shape of a submarine’s propeller, thereby ensuring the highest productivity with minimal noise level (23 dB)



Unique patented design of the hidden mechanism (autoshutters) prevent reverse airflow after the power unit deletion



10 years guarantee under 24 hours non stop operation of the fan confirms the high quality, durability and reliability of products manufactured by BLAUBERG



Ordering Information Part Number

Timer

Humidity Sensor

BLAECO100 BLAECO100P

n/a n/a

n/a n/a

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 27

DOMESTIC



Overall and installation dimensions

Model Number ECO100



a 180

Dimensions mm b c d 160 85 96

Specifications

Parameters

Eco 100



e 55

Eco 100

Voltage,V

220-240

Power, W

6

Extract capacity, m3/h

70

Noise level, dBA 3m

23

Safety regulations

IP 22



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

27

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 28

DOMESTIC 150mm SERIES

SL150 SL150KIT

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions





Application Low profile fascia Single speed axial fan Ball bearing motor Silent impeller Easy maintenance Built-in back draught shutter 3 year warranty



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑

Part Number SL150 SL150KIT

28

Timer

Humidity Sensor

n/a n/a

n/a n/a

THEVENTILATION VENTILATION SPECIALISTS 13001300 555 586 066 666 www.ventilationspecialists.com.au THE SPECIALISTSPh: Ph: 555 Fax: 586 1300 Fax:666 1300 066 www.repelec.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 29

DOMESTIC



Overall and installation dimensions

Model Number SL150

D

A

B

B 10

F 140

F

E

Specifications

Static pressure, Pa



C

A 140

Dimensions mm C D E 98 99 140

Parameters

SL150

SL100

SL150

Voltage,V

220-240

220-240

Power, W

37

37

Extract capacity, m3/h

218

218

Noise level, dBA 3m

43

43

Flow rate, m3/h



Safety regulations

IP 22



Packing

THETHE VENTILATION SPECIALISTS Ph: 1300Ph: 5551300 586 Fax: 066 www.ventilationspecialists.com.au VENTILATION SPECIALISTS 555 1300 586 666 Fax: 1300 666 066 www.repelec.com.au

29

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 30

DOMESTIC WX SERIES

WX6 WX9

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Concealed Wall Fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions

30

■ ❑

Application Low energy consumption of the motor (6 W) elaborated by BLAUBERG engineers



Noiseless impeller’s blades resemble the shape of a submarine’s propeller, thereby ensuring the highest productivity with minimal noise level (23 dB)



Unique patented design of the hidden mechanism (autoshutters) prevent reverse airflow after the power unit deletion



10 years guarantee under 24 hours non stop operation of the fan confirms the high quality, durability and reliability of products manufactured by BLAUBERG



Ordering Information Part Number

Timer

Humidity Sensor

WX6 WX9

n/a n/a

n/a n/a

THEVENTILATION VENTILATION SPECIALISTS 13001300 555 586 066 666 www.ventilationspecialists.com.au THE SPECIALISTSPh: Ph: 555 Fax: 586 1300 Fax:666 1300 066 www.repelec.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 31

DOMESTIC



Overall and installation dimensions

B

B

Dimensions mm A B 321 290 433 409

Model Number WX6 WX9

A

A

WX6 ■

WX9

Specifications

Static pressure, Pa

Volume (C.M.F.)

Parameters

WX6

WX9

220-240

220-240

34

41

Extract capacity, m /h

246

783

Noise level, dBA 3m

39

50

Voltage,V Power, W 3

WX6

WX9

Flow rate in m3/h



Safety regulations

IP 22



Packing

THETHE VENTILATION SPECIALISTS Ph: 1300Ph: 5551300 586 Fax: 066 www.ventilationspecialists.com.au VENTILATION SPECIALISTS 555 1300 586 666 Fax: 1300 666 066 www.repelec.com.au

31

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 32

DOMESTIC AERO CLASSIC

Aero 100 Aero 125 Aero 150

■ ❑ ■

Application Wall/ceiling fan ■



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous running Back valve Ball bearing motor 5 year guarantee



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min

32

Part Number BLAAERO100 BLAAERO100S BLAAERO100T BLAAERO100ST BLAAERO100H BLAAERO100SH BLAAERO125 BLAAERO125S BLAAERO125T BLAAERO125ST BLAAERO125H BLAAERO125SH BLAAERO150 BLAAERO150S BLAAERO150T BLAAERO150ST BLAAERO15H BLAAERO150SH

Pull-cord switch

Timer

Humidity Sensor

● ● ●

● ●





● ● ●

● ●





● ● ●

● ●





THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 33

DOMESTIC



Overall and installation dimensions

Model Number AERO100 AERO125 AERO150



Dimensions mm b c d 122 92.5 100 144 97 125 170 119 150

a 144 168 198

e 29.5 30 30

Specifications

Parameters

Aero 150 Aero 125 Aero 100



Safety regulations



Packing

Aero 100

Aero 125

Aero 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Extract capacity, m3/h

102

193

309

Noise level, dBA 3m

38

39

40

2300

2400

2400

r.p.m.

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

33

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 34

DOMESTIC AERO STILL

Only

5.5 W* 25 dBA*

Aero Still 100 Aero Still 125 Aero Still 150 Aero Still Gold ■ ❑ ■

Aero Still Chrome

Application Wall/ceiling fan ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous running Back valve Ball bearing motor Decorative option - Aero Still Gold, Aero Still Chrome 5 years guarantee



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min

Part Number BLAAEROSTILL100 BLAAEROSTILL100S BLAAEROSTILL100T BLAAEROSTILL100ST BLAAEROSTILL100H BLAAEROSTILL100SH BLAAEROSTILL125 BLAAEROSTILL125S BLAAEROSTILL125T BLAAEROSTILL125ST BLAAEROSTILL125H BLAAEROSTILL125SH BLAAEROSTILL150 BLAAEROSTILL150S BLAAEROSTILL150T BLAAEROSTILL150ST BLAAEROSTILL150H BLAAEROSTILL150SH

Pull-cord switch

Timer

Humidity Sensor

● ●

● ● ● ●

● ● ●

● ● ● ●

● ● ●

● ● ● ●



Note: To order decorative option please add the following suffix after the part number: Gold (G), Chrome (C)

* for Aero Still 100

34

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 35

DOMESTIC



Overall and installation dimensions

Model Number AEROSTILL100 AEROSTILL125 AEROSTILL150



Dimensions mm b c d 122 92.5 100 144 97 125 170 119 150

a 144 168 198

e 29.5 30 30

Specifications

Aero Still 100

Aero Still 125

Aero Still 150

Voltage,V

220-240

220-240

220-240

Power, W

5.5

9.4

19.0

Extract capacity, m3/h

84

158

254

Noise level, dBA 3m

25

31

33

Parameters

Aero Still 150 Aero Still 125 Aero Still 100



Safety regulations



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

35

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 36

DOMESTIC BRAVO

Bravo 100 Bravo 125 Bravo 150 Bravo Chrome ■ ❑ ■

Bravo Platinum

Application Wall/ceiling fan ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - Bravo Chrome, Bravo Platinum 5 years guarantee



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Part Number

Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min

BLABRAVO100 BLABRAVO100S BLABRAVO100T BLABRAVO100ST BLABRAVO100H BLABRAVO100SH BLABRAVO100IR BLABRAVO125 BLABRAVO125S BLABRAVO125T BLABRAVO125ST BLABRAVO125H BLABRAVO125SH BLABRAVO125IR BLABRAVO150 BLABRAVO150S BLABRAVO150T BLABRAVO150ST BLABRAVO150H BLABRAVO150SH BLABRAVO150IR

Pull-cord switch

Timer

Humidity Sensor

Motion Sensor

● ●

● ● ● ●



● ●

● ● ● ●



● ● ●

● ● ● ●

Note: To order decorative option please add the following suffix after the part number: Chrome (C), Platinum (P)

36

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 37

DOMESTIC



Overall and installation dimensions

Model Number BRAVO100 BRAVO125 BRAVO150



Dimensions mm b c d 122 102 100 144 104 125 174 124 150

a 150 176 205

e 17 17 19

Specifications

Parameters

Bravo 150 Bravo 125 Bravo 100



Safety regulations



Packing

Bravo 100

Bravo 125

Bravo 150

Voltage,V

220-240

220-240

220-240

Power, W

14

16

24

Extract capacity, m3/h

101

192

305

Noise level, dBA 3m

2300

37

39

r.p.m

2300

2400

2400

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

37

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 38

DOMESTIC BRAVO STILL

Only

5.6 W* 26 dBA*

Bravo Still 100 Bravo Still 125 Bravo Still 150 Bravo Still Chrome ■ ❑ ■

Bravo Still Platinum

Application Wall/ceiling fan ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - Bravo Chrome, Bravo Platinum 5 years guarantee



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Part Number

Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min

BLABRAVOSTILL100 BLABRAVOSTILL100S BLABRAVOSTILL100T BLABRAVOSTILL100ST BLABRAVOSTILL100H BLABRAVOSTILL100SH BLABRAVOSTILL100IR BLABRAVOSTILL125 BLABRAVOSTILL125S BLABRAVOSTILL125T BLABRAVOSTILL125ST BLABRAVOSTILL125H BLABRAVOSTILL125SH BLABRAVOSTILL125IR BLABRAVOSTILL150 BLABRAVOSTILL150S BLABRAVOSTILL150T BLABRAVOSTILL150ST BLABRAVOSTILL150H BLABRAVOSTILL150SH BLABRAVOSTILL150IR

Pull-cord switch

Timer

Humidity Sensor

Motion Sensor

● ●

● ● ● ●



● ●

● ● ● ●



● ● ●

● ● ● ●

Note: To order decorative option please add the following suffix after the part number: Chrome (C), Platinum (P) * for Bravo Still 100

38

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 39

DOMESTIC



Overall and installation dimensions

Model Number BRAVOSTILL100 BRAVOSTILL125 BRAVOSTILL150



Dimensions mm b c d 122 102 100 144 104 125 174 124 150

a 150 176 205

e 17 17 19

Specifications

Bravo Still 100

Bravo Still 125

Bravo Still 150

Voltage,V

220-240

220-240

220-240

Power, W

5.6

9.3

20

Extract capacity, m3/h

70

115

235

Noise level, dBA 3m

26

31

35

Parameters Bravo Still 150

Bravo Still 125

Bravo Still 100



Safety regulations



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

39

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 40

DOMESTIC BRISE

Brise 100 Brise Platinum ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

■ ❑

Application Wall/ceiling fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions

■ ❑

Modifications Brise Max - the fan with the increased capacity

Features Low energy consumption of the motor (2.7 W) elaborated by BLAUBERG engineers



Noiseless impeller’s blades have the shape of a submarine’s propeller, thereby ensuring the highest productivity with minimal noise level (23 dB)



10 years guarantee under 24 hours non stop operation of the fan



Ordering Information Part Number

BLABRISE100 BLABRISE100T BLABRISE100P BLABRISE100TP BLABRISE100MAX BLABRISE100MAXT BLABRISE100MAXP BLABRISE100MAXTP

40

Timer ● ● ● ●

Humidity Sensor n/a n/a n/a n/a n/a n/a n/a n/a

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 41

DOMESTIC



Overall and installation dimensions

Model Number BRISE100 BRISE100MAX



Dimensions mm b c d 160 85 96 160 85 96

e 40 40

Specifications

Parameters Voltage,V Power, W Brise 100 Brise 100 max



a 160 160

Brise 100

Brise 100 Max

220-240

220-240

2.7

3.5

3

Extract capacity, m /h

53

62

Noise level, dBA 3m

21

22

Safety regulations

IP 22



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

41

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 42

DOMESTIC 100mm SERIES

DX100 DX100KIT

DX100KIT ■ ❑ ■

Application 100mm Axial Extract Fans



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications

❑ ❑ ❑ ❑ ❑ ❑ ❑





Features Curved flowing grille design Single speed axial fan Ball bearing motor Silent impeller Universal mounting kit 3 year warranty



Ordering Information

❑ ❑ ❑ ❑ ❑

Part Number DX100 DX100KIT

42

Pull Cord

Timer

Humidity Sensor

n/a n/a

n/a n/a

n/a n/a

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 43

DOMESTIC



Overall and installation dimensions

Model Number DX100



A 165

Dimensions mm B C D 155 43 130

E 99

Specifications Volume (C.M.F.) Static pressure, Pa

Parameters Voltage,V Power, W DX100

DX100

DX100KIT

220-240

220-240

12

12

3

Extract capacity, m /h

76

76

Noise level, dBA 3m

35

35

Flow rate in m3/h ■

Safety regulations

IP 22



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

43

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 44

DOMESTIC HEADER FAN

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Ceiling fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions

■ ❑ ❑ ❑ ❑ ❑ ❑



Features Complies with the Australian Standard 1668.2 Quietest and most powerful of any fan in its class Inbuilt gravity shutter prevents back draught when fan is not operating Compact design, ideal for recessed ceiling mounting where limited ceiling space is a problem Unique Smartdrive© motor guarantees consistent airflow in most applications Attractive diffuser efficient in removing steam and odours outside Ordering Information Part Number

Timer

Humidity Sensor

AIRAW908 AIRAW908KIT

n/a n/a

n/a n/a

AIRAW908KIT

44

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 45

DOMESTIC



Overall and installation dimensions

Model Number AIRAW908 AIRAW908KIT

E 240 240

160 140

Parameters

20

Air Volume Weight Mount Dimensions (mm) Noise Power Speed Cut out size Fan Type

00 80 60 40 20 0 14



Dimensions mm B C D 100 210 210 100 210 210

Specifications Static Pressure



A 145 145

28

41

165m2/h (45 l/s) 1.5 Kg 205w x 205L x 160h 40db Air Duct : 100mm & 150mm 29 Watt 1200rpm 210 x 220 mm Centrifugal fan

56 Litres / Second

Safety regulations

IP 22

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

45

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 46

DOMESTIC AERO KIT

Aero 150

■ ❑ ■

Application Thru wall fan kit ■



Features: 2500mm duct Silent impeller Easy maintenance Designed for longer continuous running Back valve Ball bearing motor 5 year guarantee



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch

Part Number BLAAERO150WALLKIT

Pull-cord switch

Pull-cord switch

Timer

Humidity Sensor

n/a

n/a

n/a

Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min

46

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 47

DOMESTIC



Overall and installation dimensions

Model Number AERO150



Dimensions mm b c d 170 119 150

a 198

e 30

Specifications

Parameters

Aero 150

Voltage,V

220-240

Power, W

24

Extract capacity, m3/h

309

Noise level, dBA 3m

40

r.p.m.



Safety regulations



Packing

Aero 150

2400

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

47

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 48

DOMESTIC BRAVO KIT

Bravo Kit

■ ❑ ■

Application Thru wall fan kit ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: 2500mm duct Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - Bravo Chrome, Bravo Platinum 5 years guarantee



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Pull-cord switch Timer

Part Number

Pull-cord switch

Timer

Humidity Sensor

BLABRAVO125WALLKIT BLABRAVO150WALLKIT

n/a n/a

n/a n/a

n/a n/a

Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min

48

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 49

DOMESTIC



Overall and installation dimensions

Model Number BRAVO125 BRAVO150



Dimensions mm b c d 144 104 125 174 124 150

a 176 205

e 17 19

Specifications

Bravo Still 125

Bravo Still 150

Voltage,V

220-240

220-240

Power, W

16

24

Extract capacity, m3/h

192

305

Noise level, dBA 3m

37

39

2400

2400

Parameters

Bravo 150 Bravo 125

r.p.m



Safety regulations



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

49

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 50

DOMESTIC WINDOW FAN

Wind 125 Wind 150 Automatic shutters "Open" position ■ ❑ ■

Application Window fan



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications

❑ ❑ ❑ ❑ ❑ ❑ ❑

■ ❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor

Features: Window mounting Silent impeller Easy maintenance Ball bearing motor 5 years guarantee Designed for longer continuous use

Part Number BLAWIND125 BLAWIND125S BLAWIND125T BLAWIND125ST BLAWIND125H BLAWIND125SH BLAWIND125IR BLAWIND150 BLAWIND150S BLAWIND150T BLAWIND150ST BLAWIND150H BLAWIND150SH BLAWIND150IR

Pull-cord switch

Timer

Humidity Sensor

Motion Sensor

● ●

● ● ● ●



● ● ●

● ● ● ●

Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min

50

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 51

DOMESTIC



Overall and installation dimensions

Model Number WIND125 WIND150



a 186 210

Dimensions mm b c d 173 53 125 195 60 150

e 60 150

Specifications

Parameters Wind 150 Wind 125



Safety regulations



Packing

Wind 125

Wind 150

Voltage,V

220-240

220-240

Power, W

22

26

Extract capacity, m3/h

185

295

Noise level, dBA 3m

35

41

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

51

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 52

DOMESTIC HEAT ‘n VENT

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Bathroom Ceiling Fan 2 Light Features: Multifunctional bathroom heater 3-in-1 Comes with lamp-heater, exhaust fan and light Lighting by an incandescent lamp Long life ball bearing motor with very low noise level PVC housing with rust proof paint (FDP705A/B/C) Over heating protection Contemporary design of grilles Dust diameter: 100mm (4") Power: 110V–240V, 50Hz or 60Hz Certifications: UL, CUL, CE, KS





4 Light Features: Multifunctional bathroom heater 3-in-1 Comes with lamp-heater, exhaust fan and light Energy saving dual-heat settings (2 lamps/4 lamps) Lighting by an incandescent lamp Long life ball bearing motor with very low noise level Metal housing with rust proof paint Over heating protection Contemporary design of grilles Dust diameter: 100mm (4") Power: 110V–240V, 50Hz or 60Hz Certifications: UL, CUL, KS



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Part Number HEAT2 HEAT4

Pull-cord switch

Timer

Humidity Sensor

n/a n/a

n/a n/a

n/a n/a

HEAT4

52

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 53

DOMESTIC



Overall and installation dimensions

Heat ‘n Vent 2 (HEAT2)

Heat ‘n Vent 4 (HEAT4)

380mm

195mm

195mm

365mm 250mm



350mm 400mm

Specifications

2 Light Supply: Max Load: Fan: Fan Performance: Heat Lamps: Lamp: Ducting: Grille: Switch:

220-240VAC 50Hz 635W Centrifugal 41 l/s (tested through 3 metres of duct, one bend & grille - normal installation) 2 x 275W hard glass ES R63, 60W, 220-240V 60˚ beam angle 100mm diameter x 3 metres 100mm eggcrate Independent fan/heat/light switch included

4 Light Supply: Max Load: Fan: Fan Performance: Heat Lamps: Lamp: Ducting: Grille: Switch:

220-240VAC 50Hz 1190W Centrifugal 52 l/s (tested through 3 metres of duct, one bend & grille - normal installation) 4 x 275W hard glass ES R80, 100W, 220-240V 60˚ beam angle 100mm diameter x 3 metres 100mm eggcrate Independent fan/heat/light switch included

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

53

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 54

DOMESTIC IN-LINE FAN

Tubo 125 Kit Tubo 150 Kit

■ ❑ ■

Application Shower Fan Kit ■



Features: Duct mounting 5 meter duct Silent impeller Easy maintenance Ball bearing motor 5 year guarantee Designed for longer continuous use



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑ ❑ ❑

Timer Timer ❑ Time delay range from 2 to 30 min ■ ❑

Part Number

Pull-cord switch

Timer

Humidity Sensor

BLATURBO125KIT

n/a

n/a

n/a

BLATURBO150KIT

n/a

n/a

n/a

Accessories Bracket included

Turbo-u

54

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 55

DOMESTIC



Overall and installation dimensions

Model Number TURBO125 TURBO150



d 123 148

Dimensions mm L 115 135

I 30 30

Specifications

Parameters

Turbo 150 Turbo 125

Turbo 125

Turbo 150

Voltage,V

220-240

220-240

Power, W

22

30

Extract capacity, m3/h

245

361

Noise level, dBA 3m

39

40

2400

2400

r.p.m



Safety regulations



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

55

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 56

DOMESTIC XIL SERIES

XIL150





Application In-line Axial Fan



Features: Single speed axial fan 3 metres of flexible ducting Sleek internal grilles Silent impeller Ball bearing motor 3 year warranty



Ordering Information

❑ ❑ ❑ ❑ ❑

Part Number XIL150

Internal Grille

In-Line Duct Fan

In-Line Back Draught Shutter

56

Pull-cord switch

Timer

Humidity Sensor

n/a

n/a

n/a

External Grille

Flexible Ducting

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 57

DOMESTIC



Overall and installation dimensions

Model Number XIL150



Dimensions mm B 177

A 148

C 108

Specifications Volume (C.M.F.)

Static pressure, Pa

Parameters Voltage,V

XIL150 220-240

Power, W

25

Extract capacity, m /h

133

Noise level, dBA 3m

45

3

r.p.m

2300

XIL150

Flow rate in m3/h ■

Safety regulations



Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

57

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 58

DOMESTIC TUBO

Tubo 100 Tubo 125 Tubo 150

■ ❑ ■

Application In-line Fan ■



Features: Duct mounting Silent impeller Easy maintenance Ball bearing motor 5 years guarantee Designed for longer continuous use



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

Timer

❑ ❑ ❑ ❑ ❑

Part Number

Timer ❑ Time delay range from 2 to 30 min

BLATURBO100



BLATURBO125



Accessories Bracket included

BLATURBO100T BLATURBO125T

Timer

● ●

BLATURBO150 BLATURBO150T



Turbo-u

58

THEVENTILATION VENTILATION SPECIALISTS 13001300 555 586 066 666 www.ventilationspecialists.com.au THE SPECIALISTSPh: Ph: 555 Fax: 586 1300 Fax:666 1300 066 www.repelec.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 59

DOMESTIC



Overall and installation dimensions

Model Number TURBO100 TURBO125 TURBO150



d 98 123 148

Dimensions mm L 115 115 135

i 30 30 30

Specifications

Parameters

Turbo 150 Turbo 125

Turbo 100

Turbo 125

Turbo 150

Voltage,V

220-240

220-240

220-240

Power, W

16

22

30

Extract capacity, m3/h

137

245

361

Noise level, dBA 3m

38

39

40

2300

2400

2400

r.p.m



Safety regulations



Packing

THETHE VENTILATION SPECIALISTS Ph: 1300Ph: 5551300 586 Fax: 066 www.ventilationspecialists.com.au VENTILATION SPECIALISTS 555 1300 586 666 Fax: 1300 666 066 www.repelec.com.au

59

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 60

DOMESTIC TURBO M

Turbo M





Application Mixflow In-line Fan

❑ ❑ ❑ ❑ ❑ ❑



Features: Specially designed for ventilation ducts High pressure, strong airflow and low noise level Quiet and safe operating Compact Speed switch Access to motor and impeller without ducts dismounting Overall and installation dimensions Part Number BLATURBOM100 BLATURBOM100MAX BLATURBOM125 BLATURBOM125MAX BLATURBOM150 BLATURBOM160 BLATURBOM200 BLATURBOM250 BLATURBOM315



Dimensions mm ∅D1 L 126 246 185 367 136 246 185 295 185 295 185 295 126 126 256 383 323 445

∅D 96 96 123 123 148 158 197 247 310

H 190 250 190 250 250 250 261 320 408

Specifications Dimensions

Turbo M 100

Turbo M 100 Max

Turbo M 125

Turbo M 125 Max

Turbo M 150

Turbo M 160

Turbo M 200

Turbo M 250

Turbo M 315

Speed

Max Min

Max Min

Max Min

Max Min

Max Min

Max Min

Max Min

Max Min

Max Min

Voltage, V

230

230

230

230

230

230

230

230

230

Power, W

28 25

65 47

38 28

65 47

76 54

76 54

125 90

188 140

420 270

Extract capacity, m3/h

187 145

190 180

280 220

345 285

552 467

552 467

1040 830

1350 1160

2540 1890

Noise level, dBA 3m

35 28

37 29

36 29

42 31

44 33

44 33

52 45

55 47

58 49

r.p.m.

2500 2450

2500 2400

2500 2400

2500 2400

2450 2350

2450 2350

2510 2055

2690 2360

2660 1980

Consumption current, A

0.25 0.16

0.28 0.21

0.26 0.19

0.28 0.21

0.34 0.24

0.34 0.24

0.55 0.40

0.92 0.63

1.83 1.20

60

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 61

DOMESTIC

Extract capacity, m3/h

Air pressure, Pa

Air pressure, Pa



Air pressure, Pa Extract capacity, m3/h

Extract capacity, m3/h

Extract capacity, m3/h

Extract capacity, m3/h

Extract capacity, m3/h

Air pressure, Pa

Air pressure, Pa

Air pressure, Pa

Extract capacity, m3/h

Air pressure, Pa

Air pressure, Pa

Specifications Air pressure, Pa



Extract capacity, m3/h

Extract capacity, m3/h

Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

61

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 62

DOMESTIC GRILLES

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application For extract ventilation ■

For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions

Part Number

❑ ❑ ❑ ❑ ❑

Gravity

Eggcrate

Features: Wall mounting Easy maintenance Connection with rectangular or round ducts ABS plastic Temperature resistant, UV protected antistatic plastic

Size

Fixed

REVGR100GYF REVGR100GYG REVGR100WHE REVGR100WHF REVGR100WHG REVGR125GYF REVGR125GYG REVGR125WHE REVGR125WHF REVGR125WHG REVGR150GYF REVGR150GYG REVGR150WHE REVGR150WHF REVGR150WHG

100mm 100mm 100mm 100mm 100mm 125mm 125mm 125mm 125mm 125mm 150mm 150mm 150mm 150mm 150mm



62

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

● ● ● ● ● ● ● ● ● ● ● ● ● ●

Colour Grey Grey White White White Grey Grey White White White Grey Grey White White White

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 63

DOMESTIC



Overall and installation dimensions

a

b

Dimensions mm D

I

I

REVGR100GYF

140

140

100

40.5

12.5

REVGR100GYG

140

140

100

40.5

12.5

REVGR100WHE

140

140

100

40.5

12.5

REVGR100WHF

140

140

100

40.5

12.5

REVGR100WHG

140

140

100

40.5

12.5

Model Number



REVGR125GYF

160

160

125

40.6

12.6

REVGR125GYG

160

160

125

40.6

12.6

REVGR125WHE

160

160

125

40.6

12.6

REVGR125WHF

160

160

125

40.6

12.6

REVGR125WHG

160

160

125

40.6

12.6

REVGR150GYF

170

170

150

40.6

12.6

REVGR150GYG

170

170

150

40.6

12.6

REVGR150WHE

170

170

150

40.6

12.6

REVGR150WHF

170

170

150

40.6

12.6

REVGR150WHG

170

170

150

40.6

12.6

Packing

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

63

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 64

DOMESTIC ROUND DIFFUSERS

■ ❑ ■

Application For extract ventilation ■



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Overall and installation dimensions

❑ ❑ ❑ ❑ ❑ ❑ ❑

Part Number

64

❑ ❑ ❑ ❑ ❑

a

Features: Wall and ceiling mounting Continuous adjustment of air flow capacity Easy mounting with the help of a mounting flange Sealing ring Temperature resistant, UV protected antistatic plastic

Dimensions mm b I

D

Air pass m2

REVGR125WHC

20

110

166

105

0...0.008

REVGR150WHC

30

125

200

125

0...0.009

REVGR200WHC

32

128

246

178

0...0.008

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 65

DOMESTIC DUCTING

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑

Application For extract ventilation PVC Ducting Features: Sprial wire reinforced construction Fire retardant Non collapsing Non Rotting Vapour Proof Temperature range 6˚C + 50˚C

■ ❑ ❑ ❑ ❑ ❑ ❑ ❑





Flexible Aluminium Ducting Features: Sprial wire reinforced construction Fire resistant Non collapsing Non Rotting Vapour Proof Retains extended length Temperature range -30˚C + 140˚C



❑ ❑

Aluminium Semi Rigid Ducting Flexible but strong corrugated aluminium, spiral wound with unique interlocked and knurled continuous seam Light and self-supporting long lengths Temperature range -30˚C +250˚C

Overall and installation dimensions Part Number

Size

REVDCT1001.5ALSR

100mm

REVDCT1003AL

100mm

REVDCT1003PVC

100mm

REVDCT1253AL

125mm

REVDCT1254PVC

125mm

REVDCT1501.5ALSR

150mm

REVDCT1503AL

150mm

REVDCT1505PVC

150mm

REVDCT2003AL

200mm

PVC

Aluminium Flexible

Aluminium Semi Rigid

Length



1.5m



3m



3m ●

3m



4m ● ●



1.5m 3m 5m



3m

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

65

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 66

COMMERCIAL GXC SERIES

GXC6-MK3 GXC9

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Ventilation Wall / Window Fans For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions





Features: Rugged design Single speed axial motor Silent impeller Universal mounting kit Pull-cord 3 year warranty



Ordering Information

❑ ❑ ❑ ❑ ❑

Pull-cord switch

Timer

Humidity Sensor

GXC6-MK3



n/a

n/a

GXC9



n/a

n/a

Part Number

66

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 67

COMMERCIAL



Overall and installation dimensions

Model Number GXC6-MK3 GXC9



A 226 312

B 210 294

C 119 165

Dimensions mm D E F ØG 107 109 101 184/203 147 147 147 257/266

H 32 32

J K 4-35 112 4-35 117

Specifications Volume (C.M.F.) Static pressure, Pa

Parameters

GXC6-MK3

GXC9

220-240

220-240

30

41

Extract capacity, m /h

266

549

Noise level, dBA 3m

37

44

Voltage,V Power, W 3

GXC9

GXC6

Flow rate in m3/h



Safety regulations

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

67

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 68

COMMERCIAL GX SERIES

GX6-MK3 GX9 GX12

■ ❑ ■

Application Ventilation Wall / Window Fans ■



Features: Rugged design Single speed axial motor Silent impeller Universal mounting kit 3 year warranty



For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Modifications



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑ ❑

❑ ❑ ❑ ❑

Pull-cord switch

Timer

Humidity Sensor

GX6-MK3

n/a

n/a

n/a

GX9

n/a

n/a

n/a

GX12

n/a

n/a

n/a

Part Number

68

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 69

COMMERCIAL



Overall and installation dimensions

Model Number GX6-MK3 GX9 GX12

GX6-MK3



A 226 312 408

B 210 294 380

C 119 165 216

Dimensions mm D E F G 107 109 101 184/203 147 147 147 257/266 192 190 190 324/330

H 32 32 34

J K 4-35 112 4-35 117 4-35 161

GX9-GX12

Specifications Volume (C.M.F.)

Static pressure, Pa

Parameters

GX12

GX6-MK3

GX9

GX12

Voltage,V

220-240

220-240

220-240

Power, W

30

41

85

Extract capacity, m3/h

266

728

1614

Noise level, dBA 3m

37

50

55

GX9 GX6

Flow rate in m3/h



Safety regulations

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

69

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 70

COMMERCIAL XIDP SERIES

XIDP100 XIDP125 XIDP150

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Centrifugal In-Line Fan Kit ■

For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions



Features: Impact resistant & fire retardant housing IP44 rated motor Maintenance free ball bearing motor Speed controllable Dynamically balanced in two planes 4 metres of ducting & grilles 3 year replacement warranty



Ordering Information

❑ ❑ ❑ ❑ ❑ ❑

Pull-cord switch

Timer

Humidity Sensor

XIDP100

n/a

n/a

n/a

XIDP125

n/a

n/a

n/a

XIDP150

n/a

n/a

n/a

Part Number

EXTERNAL WALL

An extensive range of accessories are available to complete the installation of the Xpelair XIDP range of inline fans.

D

The installation diagram shows a typical XIDP ducted installation and associated accessories. A

Flexible ducting

B

Spigot plate

C

Wall duct

D

External air operated louvre shutter

E

Grille box

F

Ceiling grille

G

Worm drive clip

A

B

E

G XIDP INLINE FAN

C

SUSPENDED CEILING F

70

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 71

COMMERCIAL



Overall and installation dimensions Model Number XIDP100 XIDP125 XIDP150



Dimensions mm B C 288 30 288 30 379 30

ØA 99 124 149

D 247 247 230

Specifications

Static pressure, Pa

Volume (C.M.F.)

XIDP100 XIDP125 XIDP150

Parameters

XIDP100

XIDP125

XIDP150

Voltage,V

220-240

220-240

220-240

Power, W

85

85

99

Extract capacity, m3/h

252

360

540

Noise level, dBA 3m

24

25

25

Flow rate in m3/h



Safety regulations

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

71

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 72

COMMERCIAL WH SERIES

WH30 WH60

■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑

Application Wall Heater For use in: Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions

■ ❑ ❑ ❑ ❑



Features: Compact wall hung design Wall or ceiling mounting with multi directional positioning (WH160 only) Heavy duty steel casing with die cast aluminium guard Double safety feature of thermal cut out with auto reset with one shot fusible link

Ordering Information Pull-cord switch

Timer

Humidity Sensor

WH30

n/a

n/a

n/a

WH60

n/a

n/a

n/a

Part Number

72

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 73

COMMERCIAL



Overall and installation dimensions Model Number

A 267 276

WH30 WH60

WH30

Dimensions mm B C D 370 370 260 429 46 327

E 175 –

WH60 E C

B

B

D C A



A

D

Specifications

Parameters Voltage,V Power, W



WH30

WH60

220-240

220-240

3kw

6kw

3

Extract capacity, m /h

274

311

Noise level, dBA 3m

n/a

n/a

Safety regulations

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

73

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 74

SYSTEMS

O C

74

I M

G N

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 75

SYSTEMS

O S

N O

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

75

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 76

INDUSTRIAL

O C

76

I M

G N

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 77

INDUSTRIAL

O S

N O

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

77

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 78

AIR MOVEMENT WALL & PEDESTAL FANS

REV301MG ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

REV303MG

REVWF18

REV301MG & 303MG Features: 3 speed settings Adjustable angles of 15o downward and 60o upwards Wide sweep oscillation Low noise level Self-Lubricating 195 watt motor Positive Locking Safety Grille Fitted with 3 metre flexible cord and plug Cast aluminium reinforced blade Wall fan is easily fitted to the wall with mounting kit provided Pedestal fan has adjustable height up to 2.2m with a stable base & non scratch foot pads Weight REV301: 24.20kg Weight REV303: 14.80kg 12 months motor warranty REVWF18 Features: Motor - Capacitor start self-lubricating motor Voltage- 220V / 240V 50Hz Speed - 3 speed control Blade - Metallic blade Guard - Epoxy painted guard with safety locking clips Adjustment - Adjustable angle. Pedestal 15˚ downwards to 45˚ upwards Wall mounted 45˚ downwards to 15˚ upwards Swivel - Swivel angle from 0˚ to 90˚ Pedestal Fan - Full adjustable height to 1.35m Wall Fan - Fixed safety wall mount kit 12 months motor warranty

78



■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑

REV201MG & 203MG Features: Motor: Capacitor start self-lubricating motor Voltage: 240V 50Hz Speed: 3 speed control Blade: Metallic blade Guard: Epoxy painted with safety locking clips Motor: Self-Lubricating 105 watt motor Adjustment: Adjustable angle Pedestal 15° downwards to 45° upwards. Wall mounted 45° downwards to 15° upwards Sswivel - Swivel angle from 0° to 90° Pedestal Fan - Full adjustable height to 1.35m Wall Fan - Fixed safety wall mount kit 12 months motor warranty

Ordering Information Part Number

Size

REV301MG

Pullcord

3 Position Switch

Pedestal

635mm





REV303MG

635mm



REV201MG

458mm



REV203MG

458mm



REVWF18

458mm



REVWF16

406mm



Wall

● ● ● ● ●



THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 79

AIR MOVEMENT



Overall and installation dimensions C C

J

G H

A

45˚ 15˚

UPWARD (max) A DOWNWARD (max)

GH

I

I

J B (min) B (max)

B (min) B (max) E

15˚ UPWARD (max) A

30˚

45˚

DOWNWARD (MAX)

F

D

C

Part Number

DOWNWARD (max)

F

Dimensions mm D E F

A

B min

B max

C

G

H

I

REV301MG

689

1710

2100

369

662

785

445

231

114

115

J

REV303MG

689

1710

2100

369

662

785

445

231

114

115

REV201MG

508

1310

1960

310

512

558

520

160

130

100

9

REV203MG

508

1310

1960

310

512

558

520

160

130

100

9

REV301MG & REV303MG Specifications 1

Speed Settings 2

3

Fan speed (RPM)

1120

1280

1400

AIR delivery (CFM)

5500

6300

7000

Air Delivery (M3/min)

156

178

198

Noise Level (Dba)

54.5

58.8

68

Power Input (watts)

135

150

175

Current Measure (amps)

0.56

0.60

0.80

1

Speed Settings 2

3

Fan Speed (RPM)

1050

1260

1400

AIR Delivery (CFM)

3500

3700

4000

Air Delivery (M3/Min)

99

104

112

Noise Level (Dba)

52

54

56

Power Input (Watts)

85

95

105

0.39

0.42

0.50

REV201MG & REV203MG Specifications

Current Measure (Amps)

THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au

79

TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 80

Proudly Distributed by

Repelec (Aust) ABN 13 003 762 641

Phone: 1300 555 586 Fax: 1300 666 066 NEW SOUTH WALES 16 Rayben Street, Glendenning NSW 2761

NORTHERN TERRITORY Lot 3919 Hidden Valley Rd, Berrimah NT 0820

TASMANIA 51 Glen Dhu Street, Invermay TAS 7250

QUEENSLAND 17 Sudbury Street, Darra QLD 4076

VICTORIA 4 Enterprise Court, Mulgrave VIC 3170

TVS products available from:

SOUTH AUSTRALIA 95 Harrison Road, Dudley Park SA 5008

WESTERN AUSTRALIA 15 Mordaunt Circuit, Canning Vale WA 6155