TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 1
THE VENTILATION SPECIALISTS
Ventilation Solutions Product Guide 2011
L
S
L
AIR MOVEM EN
INDUST
RIA
SYST
EM
COMMER CIA
DOME ST I
C
T
Edition 2
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 2
BRANDS
2
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 3
INTRODUCTION
Welcome to TVS TVS was formed in 2011 to provide a comprehensive range of ventilation products from many leading brands covering domestic, commercial, industrial, and air movement applications. We are part of a larger national distribution organisation, with over 15 years experience in designing, specifying, and supplying ventilation solutions throughout the Australian marketplace. Our new range includes products from European market-leading brands Blauberg, Greenwood and Xpelair. These brands are known for their reliability and evolving technology, which will ensure TVS leads the way as “your ventilation solutions provider”. Coupled with products already available from Revelair and Airware, we have chosen our new portfolio specifically to meet the expectations of the Australian marketplace. As reliability is a critical factor in fan performance all TVS fans have been selected with ball bearing motors. A ball bearing motor will ensure our fans perform consistently for a number of years. As a result we support all exhaust fans with a 2 - 5 year replacement warranty. Within the range there are a wide variety of installation solutions, from ceiling, window, and wall-mounted fans, to complete in-duct ventilation solutions which will meet the most demanding array of applications. You can choose from a Classic model which offers high performance, or one of our superior specification models like the Bravo which are designed to be used in harsher and more demanding environments. These higher end models also offer faster and easier installation for the contractor. For a modern look within the home, we offer a range of designer models including the Quatro, Art, Lux, Ice and Glory just to name a few. These will offer the consumer stylish visual appeal to match current trends in bathroom decor. TVS has a ventilation product for every application. Continual development and innovation will ensure that future market demands are not only met but exceeded.
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
3
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 4
THE RANGE
4
QUATRO
ART
LUX
ICE
GLORY
AUTO
ECO
150mm SERIES
WX SERIES
AERO
AERO STILL
BRAVO
BRAVO STILL
BRISE
100mm SERIES
HEADER BOX FAN
AERO KIT
BRAVO KIT
WIND
HEAT 'n VENT
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.repelec.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 5
THE RANGE
IN-LINE FAN
XIL SERIES
TUBO
TURBO M
GRILLES
ROUND DIFFUSERS
DUCTING
GX SERIES
XIDP SERIES
WH SERIES
COMING SOON
COMING SOON
COMING SOON
COMING SOON
COMING SOON
COMING SOON
COMING SOON
COMING SOON
COMING SOON
WALL & PEDESTAL FANS
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.repelec.com.au
5
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 6
CONTENTS
DOMESTIC WALL FANS Quatro ........................................................................................................................................................14-15 Art ..............................................................................................................................................................16-17 Lux ..............................................................................................................................................................18-19 Ice ..............................................................................................................................................................20-21 Glory ..........................................................................................................................................................22-23 Auto............................................................................................................................................................24-25 Eco ..............................................................................................................................................................26-27 150mm Series ............................................................................................................................................28-29 WALL /CEILING FANS Aero............................................................................................................................................................32-33 Aero Still ....................................................................................................................................................34-35 Bravo ..........................................................................................................................................................36-37 Bravo Still ..................................................................................................................................................38-39 Brise............................................................................................................................................................40-41 DX Series ....................................................................................................................................................42-43 HEADER BOX FAN Header Box Fan ........................................................................................................................................44-45 Header Box Fan Kit....................................................................................................................................44-45 THRU WALL FANS Aero Kit ......................................................................................................................................................46-47 Bravo Kit ....................................................................................................................................................48-49 WINDOW FANS Wind ..........................................................................................................................................................50-51 HEAT ‘n VENT 2 Light ........................................................................................................................................................52-53 4 Light ........................................................................................................................................................52-53 SHOWER FAN KITS Turbo 125 Kit ............................................................................................................................................54-55 Turbo 150 Kit ............................................................................................................................................54-55 IN-LINE FANS XIL Series....................................................................................................................................................56-57 Turbo ..........................................................................................................................................................58-59 Turbo M ......................................................................................................................................................60-61
6
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 7
CONTENTS
GRILLES Fixed ..........................................................................................................................................................62-63 Gravity........................................................................................................................................................62-63 Eggcrate ....................................................................................................................................................62-63 Round Diffuser ................................................................................................................................................64 DUCTING PVC ..................................................................................................................................................................65 Aluminium Flexible ........................................................................................................................................65 Aluminium Semi Rigid ....................................................................................................................................65 COMMERCIAL WINDOW / WALL FANS GXC Series..................................................................................................................................................66-67 GX Series ....................................................................................................................................................68-69 IN-LINE FANS XIDP Series ................................................................................................................................................70-71 WALL HEATER FANS WH Series ..................................................................................................................................................72-73 INDUSTRIAL
SYSTEMS
AIR MOVEMENT Wall Fan ....................................................................................................................................................78-79 Pedestal Fan ..............................................................................................................................................78-79
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
7
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 8
VENTILATION SELECTION • It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Use ducted fans, through-wall fans or window fans at all times. Do NOT use ceiling fans which discharge into the ceiling cavity - this only moves the problem. Moisture will permeate insulation and ceiling linings causing further problems. • In particular with bathrooms think in terms of “roomconditioning”. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel. Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation.
Window open ai
Fan Placement Careful location of an extraction fan will ensure maximum airflow through the room. Air extracted from a bathroom, for example, can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door. This ensures that fresh air is being drawn into the entire house at regular periods.
Use a door vent if necessary. For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room e.g. air in = air out
la
n tio
POOR CIRCULATION
on
Window closed
ti
Switching the fan on before starting showering or cooking sets up effective air-flows before the associated condensation problems occur. Closing doors to adjacent living areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door to replace extracted air.
i r c
u rc
ai
r
r ci
cu
la
MEDIUM CIRCULATION
Window closed
n atio cul r i c air
BEST CIRCULATION An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at the bottom), you may need to fit a through-door grille (see duct accessories) to allow replacement air into the room.
8
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 9
FAN REGULATIONS What the law states AS1668 (summarised): “...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces; poisonous or flammable fumes and gases...” Australian Building Code Paragraph 3.8.5.0 states: Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS 1668.2. “Mechanical ventilation for acceptable indoor air quality”, except that any contaminated air from a sanitary compartment or bathroom must: (a) Exhaust directly to outside the building by way of ducts; or (b) Exhaust into the roof space provided: i.
It is adequately ventilated by open eaves, and/or roof vents; or ii. The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles. As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents. The TVS range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the latest building code. Natural ventilation for the above is acceptable as long as opening windows in each room have an area of 5% or more of the floor area of the room.
Bathrooms The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed
Toilets The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed
Kitchens The regulations require a fan capable of a minimum extraction capacity of 50 litres per second when installed
Laundries The regulations require a fan capable of a minimum extraction capacity of 20 litres per second when installed
LEGEND ● Pull-Cord Switch ● Timer ● Humidity Sensor
Motion Sensor ● Fixed ● Gravity ● Eggcrate ● PVC ● Aluminium Flexible ● Aluminium Semi Rigid
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
9
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 10
CIRCULATING FAN PERFORMANCE
1. Litres/Second (l/s)
4. Working out the right fan for the job
milk 1 litre
1. Calculate the room volume in metres (L x W x H) 2. Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit. 3. The result is the total performance required in cubic metres per hour.
1m 1m
2. Cubic Metres/Hour (m3/hr)
1m
To convert from one to other types of measurement:
For Example: What is the best fan for a bathroom that is 2.8m long by 2.8m wide with a ceiling height of 2.4m?
If you know Litres/Second (l/s): l/s x 3.6 = m3/hr. (e.g. 25 l/s x 3.6 = 90m3/hr)
1. Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4 = 18.8m3
If you know Cubic Metres/Hour (m3/hr): m3/hr ÷ 3.6 = l/s (e.g. 200m3/hr ÷ 3.6 = 55.55 l/s
2 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m3/hr.
3. ACH (Air changes per hour). The number of times the total room volume of air is changed each hour.
Refer to the table below for the recommended Air Changes per hour based on the room type. Application Description
Air Changes Per Hour
Bathrooms
11 - 15
Kitchens - (private)
15 - 20
Laundries - (no drier)
6 - 10
Laundries - (with drier) Toilets
10 - 30 6 - 10
Bedroom
2-5
Offices
Select a fan with a higher performance than this figure
3. The fan to choose for this bathroom would be a fan that performs at greater than 282m3/hr. A fan that has a performance level of 313m3/hr or higher (eg. BRAVO150, or TURBO150KIT) would do this job. 5. Converting measurements Quick Cross-Reference Calculations Known To Find Action l/s m3/hr cfm cfm
m3/hr l/s m3/hr l/s
m3/hr to l/s to cfm Comparison Chart
10 - 12
Canteens
8 - 12
Garages
6-8
Kitchens - (commercial)
240
110
400
6 - 10
Cafés
l/s x 3.6 =m3/hr m3/hr ÷ 3.6 = l/s cfm x 1.69 =m3/hr cfm x 0.47 = l/s
220
100 350
200
90 300
180
80
160 70
250
140
20 - 30
60 120
200
Restaurants
8 - 12
Factories
8 - 10
Stores & Warehouses
3-6
Libraries
3-5
50 100 150
40
80
30
100
60
20
40
10
20
50
Classroom
5-7 0
10
m3/hr
l/s
cfm
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 11
WHAT EFFECTS PERFORMANCE?
Simple facts: 1. Fan size (i.e diameter of impeller & outlet) 2. Duct and the way it is installed Smaller duct = greater resistance to airflow. More bends = greater resistance to airflow. Longer duct runs = increasingly reduced airflow. Wrinkled ducting causes turbulence and reduces airflow
Compare Centrifugal Against Axial Fan Performance: 1. Axial 100mm vs 100mm Centrifugal fan The starting point is the free air performance of 23l/s for the axial and 31l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases volume of air moved. From the below example you can see that at 20Pa of pressure the 100mm axial fan airflow has stopped whereas the 100mm centrifugal fan is still moving 29l/s!
Smoother, extended ducting allows smooth, increased airflow
REVELAIR ALUDUCT flexible ducting retains its stretched-out shape (for smooth airflow) far better than most competitive products. Many competitive ducts tend to shrink back on themselves, wrinkling the duct fabric. 3. Fan type Centrifugal Flow Pressure developing fans which achieve good flow against the resistance created in a ducted system. Particularly useful in venting areas like internal bathrooms / laundries, multi-room extraction systems, heat-transfer systems, etc.
2. Axial 150mm fan vs 150mm Centrifugal fan The starting point is the free air performance of 89l/s for the axial and 115l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases the volume of air moved. From the below example you can see that at 120Pa of pressure the 150mm axial fan airflow has stopped whereas the 150mm centrifugal fan is still moving 102l/s!
Mix Flow Powerful in-duct mounted fans, designed for applications that require high air flows, with low relative noise. Axial Flow Suitable for wall, window and roof applications where they can extract directly to the outside. Short duct runs are an option but the length of duct should be limited. e.g. 100mm dia : 2-3m length 125mm dia : 3-4m length 150mm dia : 4-5m length
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
11
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 12
FAN APPLICATIONS Locate your Ventilation Fan Location of your ventilation fan will depend on the physical constraints of your room. The visual recognition guide (shown on the right) will help you decide the most suitable physical installation to meet your requirements. Within the above mounting options there are various other features available, such as : • TIMER (maintain fan run-on after the room is vacated) • PULLCORD (Switch at fan, instead of light switch control) • AUTO-SHUTTER (electrically operated shutters inside the fan - closed when the fan is not running to stop draughts). • PIR SENSOR (provide automatic motion-sensor control of fans)
Low voltage Shower
Wall/Ceiling Mounted Fans Thru Wall Fan Kits In-Line Fan Kits
Window Fans Thru Roof Fan Kits Low Voltage Fans
Wet Areas & Recommended Fan Types When considering where in the room to place an extractor fan, you must consider the wet areas.
Zone 2: This zone is 0.6 metres horizontally outside of zone 1 and 2.25 metres above the floor
Outside Zones
Outside Zones 0.25m 2.4m
0.6m
0.6m
ZONE 2 2.25m
Zone 1: This is the zone directly within the shower or bath up to 2.25 metres above the floor and 150mm around the bath/shower cubicle. A SELV fan or an ln-line fan kit will be required in this zone. For example if a fan is mounted directly over the bath or shower it must be a low voltage fan (SELV).
ZONE 3
ZONE 1
ZONE 1
ZONE 2
2.4m
ZONE 3
150mm
2 3
Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally outside of zone 2 and 2.25 metres above the floor.
12
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 13
FAN APPLICATIONS EXAMPLES
Ceiling Mounted Fan: Designed for low-pitch roofs or between floors, where there is no ceiling access. This enables the fan to be accessible for service after installation. Also available with heat lamps & lighting.
Duct
Ceiling Fan
Fixed Grille
Thru Wall Fan Kit: Used where the bathroom is on an external wall, or there is no ceiling space for an in-line fan.
Duct Gravity Grille
Fan Motor
Window Fan
Fan Motor PVC Duct Fixed Grille
Window Mounted Fan: Used in situations where an existing window fan is being replaced, or where there is no available external wall space and no ceiling space access.
In-line Fan Kit: Most common bathroom installation, the fan is mounted in the ceiling space with the grille directly above the source of the steam. Generally this type of installation is quieter as the fan is not directly in the room.
Roof Cowl Kit Fan Motor PVC Duct Fixed Grille
Thru Roof Kit Used where there is limited access to the roof space, or where there is no soffit available. Thru Roof Kits can be used with any extraction fan, or use a Thru Roof Fan Kit with the fan mounted within the cowl.
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
13
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 14
DOMESTIC QUATRO
Quatro 100 Quatro 125 Quatro 150 Quatro Platinum ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
■
Quatro Hi-tech
Quatro Chrome
Quatro Gold
Application Wall fan ■
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - metallic (Quatro Platinum), aluminum (Quatro Hi-Tech), chrome (Quatro Chrome), gold (Quatro Gold) 5 years guarantee
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
Modifications Pull-cord switch
Part Number Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min
BLAQUATRO100 BLAQUATRO100S BLAQUATRO100T BLAQUATRO100ST BLAQUATRO100H BLAQUATRO100SH BLAQUATRO125 BLAQUATRO125S BLAQUATRO125T BLAQUATRO125ST BLAQUATRO125H BLAQUATRO125SH BLAQUATRO150 BLAQUATRO150S BLAQUATRO150T BLAQUATRO150ST BLAQUATRO150H BLAQUATRO150SH
Pull-cord switch
Timer
Humidity Sensor
● ●
● ● ● ●
● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
Note: To order decorative option please add the following suffix after the part number: Metallic (QP), Aluminium (QHT), Chrome (QC), Gold (QG)
14
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 15
DOMESTIC
■
Overall and installation dimensions
Model Number QUATRO100 QUATRO125 QUATRO150
■
Dimensions mm b c d 151 108 100 178 113 125 207 165 150
a 171 201 236
e 32 35 38
Specifications
Quatro 100
Quatro 125
Quatro 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Extract capacity, m3/h
88
167
265
Noise level, dBA 3m
33
34
37
2300
2400
2400
Parameters Quatro 150 Quatro 125
Quatro 100
■
Safety regulations
■
Packing
r.p.m
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
15
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 16
DOMESTIC ART STEEL
Art 100 Art 125 Art 150
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Stainless steel front cover options 5 years guarantee
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
Part Number
Timer
Humidity Sensor
BLAART100 BLAART125 BLAART150
n/a n/a n/a
n/a n/a n/a
Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)
16
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:01 PM Page 17
DOMESTIC
■
Overall and installation dimensions
Model Number ART100 ART125 ART150
■
a 180 204 230
e 49 55 53
Specifications
Parameters Art 150
Art 125
Art 100
■
Dimensions mm b c d 120 142 100 140 147 125 165 155 150
Art 100
Art 125
Art 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Extract capacity, m3/h
88
167
265
Noise level, dBA 3m
33
34
37
2300
2400
2400
r.p.m
Safety regulations
IP 34
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
17
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 18
DOMESTIC LUX STEEL
Lux 100 Lux 125 Lux 150
■ ❑ ■
Application Wall fan ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Ball bearing motor Stainless steel front cover options Built-in LED-Lamp (2 W) 5 years guarantee
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑ ❑
Timer
Part Number
Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min
18
BLALUX100 BLALUX100T BLALUX100H BLALUX125 BLALUX150
Timer
Humidity Sensor
● ●
Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 19
DOMESTIC
■
Overall and installation dimensions
Model Number LUX100 LUX100T LUX100H LUX125 LUX150
■
Dimensions mm b c d 120 143 100 122 151.6 98 122 151.6 98 140 152 125 165 169 150
a 180 183 183 204 230
e 49 65 65 55 53
Specifications
Parameters Lux 150
Lux 125 Lux 100
Lux 100
Lux 125
Lux 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Current, A
0.085
0.1
0.13
Extract capacity, m3/h
89
164
258
Noise level, dBA 3m
33
34
37
2300
2400
2400
r.p.m
■
Safety regulations
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
19
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 20
DOMESTIC ICE GLASS
Ice 100 Ice 125 Ice 150
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Ball bearing motor Glass front cover option 5 years guarantee
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑
Part Number
Timer
Humidity Sensor
BLAICE100 BLAICE125 BLAICE150
n/a n/a n/a
n/a n/a n/a
Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)
20
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 21
DOMESTIC
■
Overall and installation dimensions
Model Number ICE100 ICE125 ICE150
■
a 183 205 233
e 58 58 58
Specifications
Parameters Ice 150
Ice 125
Ice 100
Ice 100
Ice 125
Ice 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Current, A
0.085
0.1
0.19
Extract capacity, m3/h
105
185
298
Noise level, dBA 3m
37
38
40
2300
2400
2400
r.p.m
■
Dimensions mm b c d 120 151 100 140 156 125 165 173 150
Safety regulations
IP 34
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
21
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 22
DOMESTIC GLORY GLASS
Glory 100 Glory 125 Glory 150
■ ❑ ■
Application Wall fan ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Ball bearing motor Glass front cover options Built-in LED-Lamp (2W) 5 years guarantee
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑ ❑
Timer Part Number
Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min
22
BLAGLORY100 BLAGLORY100T BLAGLORY100H BLAGLORY125 BLAGLORY150
Timer
Humidity Sensor
● ●
Note: To order optional faces please add the following suffix after the part number: (2) (3) (4) (5) (6)
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 23
DOMESTIC
■
Overall and installation dimensions
Model Number GLORY100 GLORY100T GLORY100H GLORY125 GLORY150
■
a 180 183 183 204 230
e 49 65 65 55 53
Specifications
Parameters Glory 150 Glory 125
Glory 100
Glory 100
Glory 125
Glory 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Current, A
0.085
0.1
0.13
Extract capacity, m3/h
89
164
258
Noise level, dBA 3m
33
34
37
2300
2400
2400
r.p.m
■
Dimensions mm b c d 120 143 100 122 151.6 98 122 151.6 98 140 152 125 165 169 150
Safety regulations
IP 22
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
23
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 24
DOMESTIC AUTOMATIC SHUTTERS
Auto 100 Auto 125 Auto 150
■ ❑ ■
Application Wall fan ■
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Automatic shutters Ball bearing motor 5 years guarantee
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min
24
Part Number BLAAUTO100 BLAAUTO100S BLAAUTO100T BLAAUTO100ST BLAAUTO100H BLAAUTO100SH BLAAUTO100IR BLAAUTO125 BLAAUTO125S BLAAUTO125T BLAAUTO125ST BLAAUTO125H BLAAUTO125SH BLAAUTO125IR BLAAUTO150 BLAAUTO150S BLAAUTO150T BLAAUTO150ST BLAAUTO150H BLAAUTO150SH BLAAUTO150IR
Pull-cord switch
Timer
Humidity Sensor
Motion Sensor
● ●
● ● ● ●
●
● ●
● ● ● ●
●
● ● ●
● ● ● ●
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 25
DOMESTIC
■
Overall and installation dimensions
Model Number AUTO100 AUTO125 AUTO150
■
a 166 186 210
d 100 125 150
e 30 33 34
Specifications
Parameters Auto 150 Auto 125 Auto 100
Auto 100
Auto 125
Auto 150
Voltage,V
220-240
220-240
220-240
Power, W
18
22
26
Extract capacity, m3/h
89
185
295
Noise level, dBA 3m
34
35
39
2300
2400
2400
r.p.m
■
b1 150 128 150
Dimensions mm b2 b3 c 150 150 90 173 174 98 195 196 115
Safety regulations
IP 22
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
25
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 26
DOMESTIC ECO
Eco 100 Eco Platinum ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■ ❑
Automatic shutters
"open" position
26
"closed" position
Application Low energy consumption of the motor (6 W) elaborated by BLAUBERG engineers
❑
Noiseless impeller’s blades resemble the shape of a submarine’s propeller, thereby ensuring the highest productivity with minimal noise level (23 dB)
❑
Unique patented design of the hidden mechanism (autoshutters) prevent reverse airflow after the power unit deletion
❑
10 years guarantee under 24 hours non stop operation of the fan confirms the high quality, durability and reliability of products manufactured by BLAUBERG
■
Ordering Information Part Number
Timer
Humidity Sensor
BLAECO100 BLAECO100P
n/a n/a
n/a n/a
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 27
DOMESTIC
■
Overall and installation dimensions
Model Number ECO100
■
a 180
Dimensions mm b c d 160 85 96
Specifications
Parameters
Eco 100
■
e 55
Eco 100
Voltage,V
220-240
Power, W
6
Extract capacity, m3/h
70
Noise level, dBA 3m
23
Safety regulations
IP 22
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
27
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 28
DOMESTIC 150mm SERIES
SL150 SL150KIT
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Wall fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
❑
Application Low profile fascia Single speed axial fan Ball bearing motor Silent impeller Easy maintenance Built-in back draught shutter 3 year warranty
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑
Part Number SL150 SL150KIT
28
Timer
Humidity Sensor
n/a n/a
n/a n/a
THEVENTILATION VENTILATION SPECIALISTS 13001300 555 586 066 666 www.ventilationspecialists.com.au THE SPECIALISTSPh: Ph: 555 Fax: 586 1300 Fax:666 1300 066 www.repelec.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 29
DOMESTIC
■
Overall and installation dimensions
Model Number SL150
D
A
B
B 10
F 140
F
E
Specifications
Static pressure, Pa
■
C
A 140
Dimensions mm C D E 98 99 140
Parameters
SL150
SL100
SL150
Voltage,V
220-240
220-240
Power, W
37
37
Extract capacity, m3/h
218
218
Noise level, dBA 3m
43
43
Flow rate, m3/h
■
Safety regulations
IP 22
■
Packing
THETHE VENTILATION SPECIALISTS Ph: 1300Ph: 5551300 586 Fax: 066 www.ventilationspecialists.com.au VENTILATION SPECIALISTS 555 1300 586 666 Fax: 1300 666 066 www.repelec.com.au
29
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 30
DOMESTIC WX SERIES
WX6 WX9
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Concealed Wall Fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
30
■ ❑
Application Low energy consumption of the motor (6 W) elaborated by BLAUBERG engineers
❑
Noiseless impeller’s blades resemble the shape of a submarine’s propeller, thereby ensuring the highest productivity with minimal noise level (23 dB)
❑
Unique patented design of the hidden mechanism (autoshutters) prevent reverse airflow after the power unit deletion
❑
10 years guarantee under 24 hours non stop operation of the fan confirms the high quality, durability and reliability of products manufactured by BLAUBERG
■
Ordering Information Part Number
Timer
Humidity Sensor
WX6 WX9
n/a n/a
n/a n/a
THEVENTILATION VENTILATION SPECIALISTS 13001300 555 586 066 666 www.ventilationspecialists.com.au THE SPECIALISTSPh: Ph: 555 Fax: 586 1300 Fax:666 1300 066 www.repelec.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 31
DOMESTIC
■
Overall and installation dimensions
B
B
Dimensions mm A B 321 290 433 409
Model Number WX6 WX9
A
A
WX6 ■
WX9
Specifications
Static pressure, Pa
Volume (C.M.F.)
Parameters
WX6
WX9
220-240
220-240
34
41
Extract capacity, m /h
246
783
Noise level, dBA 3m
39
50
Voltage,V Power, W 3
WX6
WX9
Flow rate in m3/h
■
Safety regulations
IP 22
■
Packing
THETHE VENTILATION SPECIALISTS Ph: 1300Ph: 5551300 586 Fax: 066 www.ventilationspecialists.com.au VENTILATION SPECIALISTS 555 1300 586 666 Fax: 1300 666 066 www.repelec.com.au
31
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 32
DOMESTIC AERO CLASSIC
Aero 100 Aero 125 Aero 150
■ ❑ ■
Application Wall/ceiling fan ■
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous running Back valve Ball bearing motor 5 year guarantee
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min
32
Part Number BLAAERO100 BLAAERO100S BLAAERO100T BLAAERO100ST BLAAERO100H BLAAERO100SH BLAAERO125 BLAAERO125S BLAAERO125T BLAAERO125ST BLAAERO125H BLAAERO125SH BLAAERO150 BLAAERO150S BLAAERO150T BLAAERO150ST BLAAERO15H BLAAERO150SH
Pull-cord switch
Timer
Humidity Sensor
● ● ●
● ●
●
●
● ● ●
● ●
●
●
● ● ●
● ●
●
●
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 33
DOMESTIC
■
Overall and installation dimensions
Model Number AERO100 AERO125 AERO150
■
Dimensions mm b c d 122 92.5 100 144 97 125 170 119 150
a 144 168 198
e 29.5 30 30
Specifications
Parameters
Aero 150 Aero 125 Aero 100
■
Safety regulations
■
Packing
Aero 100
Aero 125
Aero 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Extract capacity, m3/h
102
193
309
Noise level, dBA 3m
38
39
40
2300
2400
2400
r.p.m.
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
33
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 34
DOMESTIC AERO STILL
Only
5.5 W* 25 dBA*
Aero Still 100 Aero Still 125 Aero Still 150 Aero Still Gold ■ ❑ ■
Aero Still Chrome
Application Wall/ceiling fan ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous running Back valve Ball bearing motor Decorative option - Aero Still Gold, Aero Still Chrome 5 years guarantee
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min
Part Number BLAAEROSTILL100 BLAAEROSTILL100S BLAAEROSTILL100T BLAAEROSTILL100ST BLAAEROSTILL100H BLAAEROSTILL100SH BLAAEROSTILL125 BLAAEROSTILL125S BLAAEROSTILL125T BLAAEROSTILL125ST BLAAEROSTILL125H BLAAEROSTILL125SH BLAAEROSTILL150 BLAAEROSTILL150S BLAAEROSTILL150T BLAAEROSTILL150ST BLAAEROSTILL150H BLAAEROSTILL150SH
Pull-cord switch
Timer
Humidity Sensor
● ●
● ● ● ●
● ● ●
● ● ● ●
● ● ●
● ● ● ●
●
Note: To order decorative option please add the following suffix after the part number: Gold (G), Chrome (C)
* for Aero Still 100
34
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 35
DOMESTIC
■
Overall and installation dimensions
Model Number AEROSTILL100 AEROSTILL125 AEROSTILL150
■
Dimensions mm b c d 122 92.5 100 144 97 125 170 119 150
a 144 168 198
e 29.5 30 30
Specifications
Aero Still 100
Aero Still 125
Aero Still 150
Voltage,V
220-240
220-240
220-240
Power, W
5.5
9.4
19.0
Extract capacity, m3/h
84
158
254
Noise level, dBA 3m
25
31
33
Parameters
Aero Still 150 Aero Still 125 Aero Still 100
■
Safety regulations
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
35
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 36
DOMESTIC BRAVO
Bravo 100 Bravo 125 Bravo 150 Bravo Chrome ■ ❑ ■
Bravo Platinum
Application Wall/ceiling fan ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - Bravo Chrome, Bravo Platinum 5 years guarantee
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Part Number
Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min
BLABRAVO100 BLABRAVO100S BLABRAVO100T BLABRAVO100ST BLABRAVO100H BLABRAVO100SH BLABRAVO100IR BLABRAVO125 BLABRAVO125S BLABRAVO125T BLABRAVO125ST BLABRAVO125H BLABRAVO125SH BLABRAVO125IR BLABRAVO150 BLABRAVO150S BLABRAVO150T BLABRAVO150ST BLABRAVO150H BLABRAVO150SH BLABRAVO150IR
Pull-cord switch
Timer
Humidity Sensor
Motion Sensor
● ●
● ● ● ●
●
● ●
● ● ● ●
●
● ● ●
● ● ● ●
Note: To order decorative option please add the following suffix after the part number: Chrome (C), Platinum (P)
36
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 37
DOMESTIC
■
Overall and installation dimensions
Model Number BRAVO100 BRAVO125 BRAVO150
■
Dimensions mm b c d 122 102 100 144 104 125 174 124 150
a 150 176 205
e 17 17 19
Specifications
Parameters
Bravo 150 Bravo 125 Bravo 100
■
Safety regulations
■
Packing
Bravo 100
Bravo 125
Bravo 150
Voltage,V
220-240
220-240
220-240
Power, W
14
16
24
Extract capacity, m3/h
101
192
305
Noise level, dBA 3m
2300
37
39
r.p.m
2300
2400
2400
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
37
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 38
DOMESTIC BRAVO STILL
Only
5.6 W* 26 dBA*
Bravo Still 100 Bravo Still 125 Bravo Still 150 Bravo Still Chrome ■ ❑ ■
Bravo Still Platinum
Application Wall/ceiling fan ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Wall and ceiling mounting Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - Bravo Chrome, Bravo Platinum 5 years guarantee
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Part Number
Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min
BLABRAVOSTILL100 BLABRAVOSTILL100S BLABRAVOSTILL100T BLABRAVOSTILL100ST BLABRAVOSTILL100H BLABRAVOSTILL100SH BLABRAVOSTILL100IR BLABRAVOSTILL125 BLABRAVOSTILL125S BLABRAVOSTILL125T BLABRAVOSTILL125ST BLABRAVOSTILL125H BLABRAVOSTILL125SH BLABRAVOSTILL125IR BLABRAVOSTILL150 BLABRAVOSTILL150S BLABRAVOSTILL150T BLABRAVOSTILL150ST BLABRAVOSTILL150H BLABRAVOSTILL150SH BLABRAVOSTILL150IR
Pull-cord switch
Timer
Humidity Sensor
Motion Sensor
● ●
● ● ● ●
●
● ●
● ● ● ●
●
● ● ●
● ● ● ●
Note: To order decorative option please add the following suffix after the part number: Chrome (C), Platinum (P) * for Bravo Still 100
38
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 39
DOMESTIC
■
Overall and installation dimensions
Model Number BRAVOSTILL100 BRAVOSTILL125 BRAVOSTILL150
■
Dimensions mm b c d 122 102 100 144 104 125 174 124 150
a 150 176 205
e 17 17 19
Specifications
Bravo Still 100
Bravo Still 125
Bravo Still 150
Voltage,V
220-240
220-240
220-240
Power, W
5.6
9.3
20
Extract capacity, m3/h
70
115
235
Noise level, dBA 3m
26
31
35
Parameters Bravo Still 150
Bravo Still 125
Bravo Still 100
■
Safety regulations
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
39
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 40
DOMESTIC BRISE
Brise 100 Brise Platinum ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
■ ❑
Application Wall/ceiling fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■ ❑
Modifications Brise Max - the fan with the increased capacity
Features Low energy consumption of the motor (2.7 W) elaborated by BLAUBERG engineers
❑
Noiseless impeller’s blades have the shape of a submarine’s propeller, thereby ensuring the highest productivity with minimal noise level (23 dB)
❑
10 years guarantee under 24 hours non stop operation of the fan
■
Ordering Information Part Number
BLABRISE100 BLABRISE100T BLABRISE100P BLABRISE100TP BLABRISE100MAX BLABRISE100MAXT BLABRISE100MAXP BLABRISE100MAXTP
40
Timer ● ● ● ●
Humidity Sensor n/a n/a n/a n/a n/a n/a n/a n/a
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 41
DOMESTIC
■
Overall and installation dimensions
Model Number BRISE100 BRISE100MAX
■
Dimensions mm b c d 160 85 96 160 85 96
e 40 40
Specifications
Parameters Voltage,V Power, W Brise 100 Brise 100 max
■
a 160 160
Brise 100
Brise 100 Max
220-240
220-240
2.7
3.5
3
Extract capacity, m /h
53
62
Noise level, dBA 3m
21
22
Safety regulations
IP 22
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
41
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 42
DOMESTIC 100mm SERIES
DX100 DX100KIT
DX100KIT ■ ❑ ■
Application 100mm Axial Extract Fans
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
❑ ❑ ❑ ❑ ❑ ❑ ❑
■
❑
Features Curved flowing grille design Single speed axial fan Ball bearing motor Silent impeller Universal mounting kit 3 year warranty
■
Ordering Information
❑ ❑ ❑ ❑ ❑
Part Number DX100 DX100KIT
42
Pull Cord
Timer
Humidity Sensor
n/a n/a
n/a n/a
n/a n/a
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 43
DOMESTIC
■
Overall and installation dimensions
Model Number DX100
■
A 165
Dimensions mm B C D 155 43 130
E 99
Specifications Volume (C.M.F.) Static pressure, Pa
Parameters Voltage,V Power, W DX100
DX100
DX100KIT
220-240
220-240
12
12
3
Extract capacity, m /h
76
76
Noise level, dBA 3m
35
35
Flow rate in m3/h ■
Safety regulations
IP 22
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
43
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 44
DOMESTIC HEADER FAN
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Ceiling fan For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■ ❑ ❑ ❑ ❑ ❑ ❑
■
Features Complies with the Australian Standard 1668.2 Quietest and most powerful of any fan in its class Inbuilt gravity shutter prevents back draught when fan is not operating Compact design, ideal for recessed ceiling mounting where limited ceiling space is a problem Unique Smartdrive© motor guarantees consistent airflow in most applications Attractive diffuser efficient in removing steam and odours outside Ordering Information Part Number
Timer
Humidity Sensor
AIRAW908 AIRAW908KIT
n/a n/a
n/a n/a
AIRAW908KIT
44
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 45
DOMESTIC
■
Overall and installation dimensions
Model Number AIRAW908 AIRAW908KIT
E 240 240
160 140
Parameters
20
Air Volume Weight Mount Dimensions (mm) Noise Power Speed Cut out size Fan Type
00 80 60 40 20 0 14
■
Dimensions mm B C D 100 210 210 100 210 210
Specifications Static Pressure
■
A 145 145
28
41
165m2/h (45 l/s) 1.5 Kg 205w x 205L x 160h 40db Air Duct : 100mm & 150mm 29 Watt 1200rpm 210 x 220 mm Centrifugal fan
56 Litres / Second
Safety regulations
IP 22
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
45
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 46
DOMESTIC AERO KIT
Aero 150
■ ❑ ■
Application Thru wall fan kit ■
❑
Features: 2500mm duct Silent impeller Easy maintenance Designed for longer continuous running Back valve Ball bearing motor 5 year guarantee
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch
Part Number BLAAERO150WALLKIT
Pull-cord switch
Pull-cord switch
Timer
Humidity Sensor
n/a
n/a
n/a
Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min
46
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 47
DOMESTIC
■
Overall and installation dimensions
Model Number AERO150
■
Dimensions mm b c d 170 119 150
a 198
e 30
Specifications
Parameters
Aero 150
Voltage,V
220-240
Power, W
24
Extract capacity, m3/h
309
Noise level, dBA 3m
40
r.p.m.
■
Safety regulations
■
Packing
Aero 150
2400
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
47
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 48
DOMESTIC BRAVO KIT
Bravo Kit
■ ❑ ■
Application Thru wall fan kit ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: 2500mm duct Silent impeller Easy maintenance Designed for longer continuous use Back valve Ball bearing motor Decorative option - Bravo Chrome, Bravo Platinum 5 years guarantee
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Pull-cord switch Timer
Part Number
Pull-cord switch
Timer
Humidity Sensor
BLABRAVO125WALLKIT BLABRAVO150WALLKIT
n/a n/a
n/a n/a
n/a n/a
Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min
48
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 49
DOMESTIC
■
Overall and installation dimensions
Model Number BRAVO125 BRAVO150
■
Dimensions mm b c d 144 104 125 174 124 150
a 176 205
e 17 19
Specifications
Bravo Still 125
Bravo Still 150
Voltage,V
220-240
220-240
Power, W
16
24
Extract capacity, m3/h
192
305
Noise level, dBA 3m
37
39
2400
2400
Parameters
Bravo 150 Bravo 125
r.p.m
■
Safety regulations
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
49
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 50
DOMESTIC WINDOW FAN
Wind 125 Wind 150 Automatic shutters "Open" position ■ ❑ ■
Application Window fan
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
❑ ❑ ❑ ❑ ❑ ❑ ❑
■ ❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch Pull-cord switch Timer Timer ❑ Time delay range from 2 to 30 min Humidity Sensor Humidity ❑ Humidity level range from 50 to 90% ❑ Time delay range from 2 to 30 min Motion Sensor
Features: Window mounting Silent impeller Easy maintenance Ball bearing motor 5 years guarantee Designed for longer continuous use
Part Number BLAWIND125 BLAWIND125S BLAWIND125T BLAWIND125ST BLAWIND125H BLAWIND125SH BLAWIND125IR BLAWIND150 BLAWIND150S BLAWIND150T BLAWIND150ST BLAWIND150H BLAWIND150SH BLAWIND150IR
Pull-cord switch
Timer
Humidity Sensor
Motion Sensor
● ●
● ● ● ●
●
● ● ●
● ● ● ●
Motion Sensor ❑ Reach distance 1 to 4 m ❑ Sensor viewing angle up to 1000 ❑ Time delay range from 2 to 30 min
50
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 51
DOMESTIC
■
Overall and installation dimensions
Model Number WIND125 WIND150
■
a 186 210
Dimensions mm b c d 173 53 125 195 60 150
e 60 150
Specifications
Parameters Wind 150 Wind 125
■
Safety regulations
■
Packing
Wind 125
Wind 150
Voltage,V
220-240
220-240
Power, W
22
26
Extract capacity, m3/h
185
295
Noise level, dBA 3m
35
41
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
51
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 52
DOMESTIC HEAT ‘n VENT
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Bathroom Ceiling Fan 2 Light Features: Multifunctional bathroom heater 3-in-1 Comes with lamp-heater, exhaust fan and light Lighting by an incandescent lamp Long life ball bearing motor with very low noise level PVC housing with rust proof paint (FDP705A/B/C) Over heating protection Contemporary design of grilles Dust diameter: 100mm (4") Power: 110V–240V, 50Hz or 60Hz Certifications: UL, CUL, CE, KS
■
❑
4 Light Features: Multifunctional bathroom heater 3-in-1 Comes with lamp-heater, exhaust fan and light Energy saving dual-heat settings (2 lamps/4 lamps) Lighting by an incandescent lamp Long life ball bearing motor with very low noise level Metal housing with rust proof paint Over heating protection Contemporary design of grilles Dust diameter: 100mm (4") Power: 110V–240V, 50Hz or 60Hz Certifications: UL, CUL, KS
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Part Number HEAT2 HEAT4
Pull-cord switch
Timer
Humidity Sensor
n/a n/a
n/a n/a
n/a n/a
HEAT4
52
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:02 PM Page 53
DOMESTIC
■
Overall and installation dimensions
Heat ‘n Vent 2 (HEAT2)
Heat ‘n Vent 4 (HEAT4)
380mm
195mm
195mm
365mm 250mm
■
350mm 400mm
Specifications
2 Light Supply: Max Load: Fan: Fan Performance: Heat Lamps: Lamp: Ducting: Grille: Switch:
220-240VAC 50Hz 635W Centrifugal 41 l/s (tested through 3 metres of duct, one bend & grille - normal installation) 2 x 275W hard glass ES R63, 60W, 220-240V 60˚ beam angle 100mm diameter x 3 metres 100mm eggcrate Independent fan/heat/light switch included
4 Light Supply: Max Load: Fan: Fan Performance: Heat Lamps: Lamp: Ducting: Grille: Switch:
220-240VAC 50Hz 1190W Centrifugal 52 l/s (tested through 3 metres of duct, one bend & grille - normal installation) 4 x 275W hard glass ES R80, 100W, 220-240V 60˚ beam angle 100mm diameter x 3 metres 100mm eggcrate Independent fan/heat/light switch included
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
53
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 54
DOMESTIC IN-LINE FAN
Tubo 125 Kit Tubo 150 Kit
■ ❑ ■
Application Shower Fan Kit ■
❑
Features: Duct mounting 5 meter duct Silent impeller Easy maintenance Ball bearing motor 5 year guarantee Designed for longer continuous use
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ ❑
Timer Timer ❑ Time delay range from 2 to 30 min ■ ❑
Part Number
Pull-cord switch
Timer
Humidity Sensor
BLATURBO125KIT
n/a
n/a
n/a
BLATURBO150KIT
n/a
n/a
n/a
Accessories Bracket included
Turbo-u
54
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 55
DOMESTIC
■
Overall and installation dimensions
Model Number TURBO125 TURBO150
■
d 123 148
Dimensions mm L 115 135
I 30 30
Specifications
Parameters
Turbo 150 Turbo 125
Turbo 125
Turbo 150
Voltage,V
220-240
220-240
Power, W
22
30
Extract capacity, m3/h
245
361
Noise level, dBA 3m
39
40
2400
2400
r.p.m
■
Safety regulations
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
55
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 56
DOMESTIC XIL SERIES
XIL150
■
■
Application In-line Axial Fan
❑
Features: Single speed axial fan 3 metres of flexible ducting Sleek internal grilles Silent impeller Ball bearing motor 3 year warranty
■
Ordering Information
❑ ❑ ❑ ❑ ❑
Part Number XIL150
Internal Grille
In-Line Duct Fan
In-Line Back Draught Shutter
56
Pull-cord switch
Timer
Humidity Sensor
n/a
n/a
n/a
External Grille
Flexible Ducting
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 57
DOMESTIC
■
Overall and installation dimensions
Model Number XIL150
■
Dimensions mm B 177
A 148
C 108
Specifications Volume (C.M.F.)
Static pressure, Pa
Parameters Voltage,V
XIL150 220-240
Power, W
25
Extract capacity, m /h
133
Noise level, dBA 3m
45
3
r.p.m
2300
XIL150
Flow rate in m3/h ■
Safety regulations
■
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
57
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 58
DOMESTIC TUBO
Tubo 100 Tubo 125 Tubo 150
■ ❑ ■
Application In-line Fan ■
❑
Features: Duct mounting Silent impeller Easy maintenance Ball bearing motor 5 years guarantee Designed for longer continuous use
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
Timer
❑ ❑ ❑ ❑ ❑
Part Number
Timer ❑ Time delay range from 2 to 30 min
BLATURBO100
■
BLATURBO125
❑
Accessories Bracket included
BLATURBO100T BLATURBO125T
Timer
● ●
BLATURBO150 BLATURBO150T
●
Turbo-u
58
THEVENTILATION VENTILATION SPECIALISTS 13001300 555 586 066 666 www.ventilationspecialists.com.au THE SPECIALISTSPh: Ph: 555 Fax: 586 1300 Fax:666 1300 066 www.repelec.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 59
DOMESTIC
■
Overall and installation dimensions
Model Number TURBO100 TURBO125 TURBO150
■
d 98 123 148
Dimensions mm L 115 115 135
i 30 30 30
Specifications
Parameters
Turbo 150 Turbo 125
Turbo 100
Turbo 125
Turbo 150
Voltage,V
220-240
220-240
220-240
Power, W
16
22
30
Extract capacity, m3/h
137
245
361
Noise level, dBA 3m
38
39
40
2300
2400
2400
r.p.m
■
Safety regulations
■
Packing
THETHE VENTILATION SPECIALISTS Ph: 1300Ph: 5551300 586 Fax: 066 www.ventilationspecialists.com.au VENTILATION SPECIALISTS 555 1300 586 666 Fax: 1300 666 066 www.repelec.com.au
59
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 60
DOMESTIC TURBO M
Turbo M
■
■
Application Mixflow In-line Fan
❑ ❑ ❑ ❑ ❑ ❑
■
Features: Specially designed for ventilation ducts High pressure, strong airflow and low noise level Quiet and safe operating Compact Speed switch Access to motor and impeller without ducts dismounting Overall and installation dimensions Part Number BLATURBOM100 BLATURBOM100MAX BLATURBOM125 BLATURBOM125MAX BLATURBOM150 BLATURBOM160 BLATURBOM200 BLATURBOM250 BLATURBOM315
■
Dimensions mm ∅D1 L 126 246 185 367 136 246 185 295 185 295 185 295 126 126 256 383 323 445
∅D 96 96 123 123 148 158 197 247 310
H 190 250 190 250 250 250 261 320 408
Specifications Dimensions
Turbo M 100
Turbo M 100 Max
Turbo M 125
Turbo M 125 Max
Turbo M 150
Turbo M 160
Turbo M 200
Turbo M 250
Turbo M 315
Speed
Max Min
Max Min
Max Min
Max Min
Max Min
Max Min
Max Min
Max Min
Max Min
Voltage, V
230
230
230
230
230
230
230
230
230
Power, W
28 25
65 47
38 28
65 47
76 54
76 54
125 90
188 140
420 270
Extract capacity, m3/h
187 145
190 180
280 220
345 285
552 467
552 467
1040 830
1350 1160
2540 1890
Noise level, dBA 3m
35 28
37 29
36 29
42 31
44 33
44 33
52 45
55 47
58 49
r.p.m.
2500 2450
2500 2400
2500 2400
2500 2400
2450 2350
2450 2350
2510 2055
2690 2360
2660 1980
Consumption current, A
0.25 0.16
0.28 0.21
0.26 0.19
0.28 0.21
0.34 0.24
0.34 0.24
0.55 0.40
0.92 0.63
1.83 1.20
60
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 61
DOMESTIC
Extract capacity, m3/h
Air pressure, Pa
Air pressure, Pa
■
Air pressure, Pa Extract capacity, m3/h
Extract capacity, m3/h
Extract capacity, m3/h
Extract capacity, m3/h
Extract capacity, m3/h
Air pressure, Pa
Air pressure, Pa
Air pressure, Pa
Extract capacity, m3/h
Air pressure, Pa
Air pressure, Pa
Specifications Air pressure, Pa
■
Extract capacity, m3/h
Extract capacity, m3/h
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
61
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 62
DOMESTIC GRILLES
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application For extract ventilation ■
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
Part Number
❑ ❑ ❑ ❑ ❑
Gravity
Eggcrate
Features: Wall mounting Easy maintenance Connection with rectangular or round ducts ABS plastic Temperature resistant, UV protected antistatic plastic
Size
Fixed
REVGR100GYF REVGR100GYG REVGR100WHE REVGR100WHF REVGR100WHG REVGR125GYF REVGR125GYG REVGR125WHE REVGR125WHF REVGR125WHG REVGR150GYF REVGR150GYG REVGR150WHE REVGR150WHF REVGR150WHG
100mm 100mm 100mm 100mm 100mm 125mm 125mm 125mm 125mm 125mm 150mm 150mm 150mm 150mm 150mm
●
62
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
● ● ● ● ● ● ● ● ● ● ● ● ● ●
Colour Grey Grey White White White Grey Grey White White White Grey Grey White White White
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 63
DOMESTIC
■
Overall and installation dimensions
a
b
Dimensions mm D
I
I
REVGR100GYF
140
140
100
40.5
12.5
REVGR100GYG
140
140
100
40.5
12.5
REVGR100WHE
140
140
100
40.5
12.5
REVGR100WHF
140
140
100
40.5
12.5
REVGR100WHG
140
140
100
40.5
12.5
Model Number
■
REVGR125GYF
160
160
125
40.6
12.6
REVGR125GYG
160
160
125
40.6
12.6
REVGR125WHE
160
160
125
40.6
12.6
REVGR125WHF
160
160
125
40.6
12.6
REVGR125WHG
160
160
125
40.6
12.6
REVGR150GYF
170
170
150
40.6
12.6
REVGR150GYG
170
170
150
40.6
12.6
REVGR150WHE
170
170
150
40.6
12.6
REVGR150WHF
170
170
150
40.6
12.6
REVGR150WHG
170
170
150
40.6
12.6
Packing
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
63
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 64
DOMESTIC ROUND DIFFUSERS
■ ❑ ■
Application For extract ventilation ■
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Overall and installation dimensions
❑ ❑ ❑ ❑ ❑ ❑ ❑
Part Number
64
❑ ❑ ❑ ❑ ❑
a
Features: Wall and ceiling mounting Continuous adjustment of air flow capacity Easy mounting with the help of a mounting flange Sealing ring Temperature resistant, UV protected antistatic plastic
Dimensions mm b I
D
Air pass m2
REVGR125WHC
20
110
166
105
0...0.008
REVGR150WHC
30
125
200
125
0...0.009
REVGR200WHC
32
128
246
178
0...0.008
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 65
DOMESTIC DUCTING
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑
Application For extract ventilation PVC Ducting Features: Sprial wire reinforced construction Fire retardant Non collapsing Non Rotting Vapour Proof Temperature range 6˚C + 50˚C
■ ❑ ❑ ❑ ❑ ❑ ❑ ❑
■
■
Flexible Aluminium Ducting Features: Sprial wire reinforced construction Fire resistant Non collapsing Non Rotting Vapour Proof Retains extended length Temperature range -30˚C + 140˚C
❑
❑ ❑
Aluminium Semi Rigid Ducting Flexible but strong corrugated aluminium, spiral wound with unique interlocked and knurled continuous seam Light and self-supporting long lengths Temperature range -30˚C +250˚C
Overall and installation dimensions Part Number
Size
REVDCT1001.5ALSR
100mm
REVDCT1003AL
100mm
REVDCT1003PVC
100mm
REVDCT1253AL
125mm
REVDCT1254PVC
125mm
REVDCT1501.5ALSR
150mm
REVDCT1503AL
150mm
REVDCT1505PVC
150mm
REVDCT2003AL
200mm
PVC
Aluminium Flexible
Aluminium Semi Rigid
Length
●
1.5m
●
3m
●
3m ●
3m
●
4m ● ●
●
1.5m 3m 5m
●
3m
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
65
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 66
COMMERCIAL GXC SERIES
GXC6-MK3 GXC9
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Ventilation Wall / Window Fans For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
❑
Features: Rugged design Single speed axial motor Silent impeller Universal mounting kit Pull-cord 3 year warranty
■
Ordering Information
❑ ❑ ❑ ❑ ❑
Pull-cord switch
Timer
Humidity Sensor
GXC6-MK3
●
n/a
n/a
GXC9
●
n/a
n/a
Part Number
66
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 67
COMMERCIAL
■
Overall and installation dimensions
Model Number GXC6-MK3 GXC9
■
A 226 312
B 210 294
C 119 165
Dimensions mm D E F ØG 107 109 101 184/203 147 147 147 257/266
H 32 32
J K 4-35 112 4-35 117
Specifications Volume (C.M.F.) Static pressure, Pa
Parameters
GXC6-MK3
GXC9
220-240
220-240
30
41
Extract capacity, m /h
266
549
Noise level, dBA 3m
37
44
Voltage,V Power, W 3
GXC9
GXC6
Flow rate in m3/h
■
Safety regulations
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
67
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 68
COMMERCIAL GX SERIES
GX6-MK3 GX9 GX12
■ ❑ ■
Application Ventilation Wall / Window Fans ■
❑
Features: Rugged design Single speed axial motor Silent impeller Universal mounting kit 3 year warranty
❑
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■
Modifications
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑
Pull-cord switch
Timer
Humidity Sensor
GX6-MK3
n/a
n/a
n/a
GX9
n/a
n/a
n/a
GX12
n/a
n/a
n/a
Part Number
68
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 69
COMMERCIAL
■
Overall and installation dimensions
Model Number GX6-MK3 GX9 GX12
GX6-MK3
■
A 226 312 408
B 210 294 380
C 119 165 216
Dimensions mm D E F G 107 109 101 184/203 147 147 147 257/266 192 190 190 324/330
H 32 32 34
J K 4-35 112 4-35 117 4-35 161
GX9-GX12
Specifications Volume (C.M.F.)
Static pressure, Pa
Parameters
GX12
GX6-MK3
GX9
GX12
Voltage,V
220-240
220-240
220-240
Power, W
30
41
85
Extract capacity, m3/h
266
728
1614
Noise level, dBA 3m
37
50
55
GX9 GX6
Flow rate in m3/h
■
Safety regulations
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
69
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 70
COMMERCIAL XIDP SERIES
XIDP100 XIDP125 XIDP150
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Centrifugal In-Line Fan Kit ■
For use in: Domestic premises Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
❑
Features: Impact resistant & fire retardant housing IP44 rated motor Maintenance free ball bearing motor Speed controllable Dynamically balanced in two planes 4 metres of ducting & grilles 3 year replacement warranty
■
Ordering Information
❑ ❑ ❑ ❑ ❑ ❑
Pull-cord switch
Timer
Humidity Sensor
XIDP100
n/a
n/a
n/a
XIDP125
n/a
n/a
n/a
XIDP150
n/a
n/a
n/a
Part Number
EXTERNAL WALL
An extensive range of accessories are available to complete the installation of the Xpelair XIDP range of inline fans.
D
The installation diagram shows a typical XIDP ducted installation and associated accessories. A
Flexible ducting
B
Spigot plate
C
Wall duct
D
External air operated louvre shutter
E
Grille box
F
Ceiling grille
G
Worm drive clip
A
B
E
G XIDP INLINE FAN
C
SUSPENDED CEILING F
70
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 71
COMMERCIAL
■
Overall and installation dimensions Model Number XIDP100 XIDP125 XIDP150
■
Dimensions mm B C 288 30 288 30 379 30
ØA 99 124 149
D 247 247 230
Specifications
Static pressure, Pa
Volume (C.M.F.)
XIDP100 XIDP125 XIDP150
Parameters
XIDP100
XIDP125
XIDP150
Voltage,V
220-240
220-240
220-240
Power, W
85
85
99
Extract capacity, m3/h
252
360
540
Noise level, dBA 3m
24
25
25
Flow rate in m3/h
■
Safety regulations
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
71
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 72
COMMERCIAL WH SERIES
WH30 WH60
■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑
Application Wall Heater For use in: Apartments, houses Offices Back rooms Commercial premises Restaurants Work places Medical institutions
■ ❑ ❑ ❑ ❑
■
Features: Compact wall hung design Wall or ceiling mounting with multi directional positioning (WH160 only) Heavy duty steel casing with die cast aluminium guard Double safety feature of thermal cut out with auto reset with one shot fusible link
Ordering Information Pull-cord switch
Timer
Humidity Sensor
WH30
n/a
n/a
n/a
WH60
n/a
n/a
n/a
Part Number
72
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 73
COMMERCIAL
■
Overall and installation dimensions Model Number
A 267 276
WH30 WH60
WH30
Dimensions mm B C D 370 370 260 429 46 327
E 175 –
WH60 E C
B
B
D C A
■
A
D
Specifications
Parameters Voltage,V Power, W
■
WH30
WH60
220-240
220-240
3kw
6kw
3
Extract capacity, m /h
274
311
Noise level, dBA 3m
n/a
n/a
Safety regulations
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
73
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 74
SYSTEMS
O C
74
I M
G N
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 75
SYSTEMS
O S
N O
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
75
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 76
INDUSTRIAL
O C
76
I M
G N
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 77
INDUSTRIAL
O S
N O
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
77
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 78
AIR MOVEMENT WALL & PEDESTAL FANS
REV301MG ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
REV303MG
REVWF18
REV301MG & 303MG Features: 3 speed settings Adjustable angles of 15o downward and 60o upwards Wide sweep oscillation Low noise level Self-Lubricating 195 watt motor Positive Locking Safety Grille Fitted with 3 metre flexible cord and plug Cast aluminium reinforced blade Wall fan is easily fitted to the wall with mounting kit provided Pedestal fan has adjustable height up to 2.2m with a stable base & non scratch foot pads Weight REV301: 24.20kg Weight REV303: 14.80kg 12 months motor warranty REVWF18 Features: Motor - Capacitor start self-lubricating motor Voltage- 220V / 240V 50Hz Speed - 3 speed control Blade - Metallic blade Guard - Epoxy painted guard with safety locking clips Adjustment - Adjustable angle. Pedestal 15˚ downwards to 45˚ upwards Wall mounted 45˚ downwards to 15˚ upwards Swivel - Swivel angle from 0˚ to 90˚ Pedestal Fan - Full adjustable height to 1.35m Wall Fan - Fixed safety wall mount kit 12 months motor warranty
78
■
■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
REV201MG & 203MG Features: Motor: Capacitor start self-lubricating motor Voltage: 240V 50Hz Speed: 3 speed control Blade: Metallic blade Guard: Epoxy painted with safety locking clips Motor: Self-Lubricating 105 watt motor Adjustment: Adjustable angle Pedestal 15° downwards to 45° upwards. Wall mounted 45° downwards to 15° upwards Sswivel - Swivel angle from 0° to 90° Pedestal Fan - Full adjustable height to 1.35m Wall Fan - Fixed safety wall mount kit 12 months motor warranty
Ordering Information Part Number
Size
REV301MG
Pullcord
3 Position Switch
Pedestal
635mm
●
●
REV303MG
635mm
●
REV201MG
458mm
●
REV203MG
458mm
●
REVWF18
458mm
●
REVWF16
406mm
●
Wall
● ● ● ● ●
●
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 79
AIR MOVEMENT
■
Overall and installation dimensions C C
J
G H
A
45˚ 15˚
UPWARD (max) A DOWNWARD (max)
GH
I
I
J B (min) B (max)
B (min) B (max) E
15˚ UPWARD (max) A
30˚
45˚
DOWNWARD (MAX)
F
D
C
Part Number
DOWNWARD (max)
F
Dimensions mm D E F
A
B min
B max
C
G
H
I
REV301MG
689
1710
2100
369
662
785
445
231
114
115
J
REV303MG
689
1710
2100
369
662
785
445
231
114
115
REV201MG
508
1310
1960
310
512
558
520
160
130
100
9
REV203MG
508
1310
1960
310
512
558
520
160
130
100
9
REV301MG & REV303MG Specifications 1
Speed Settings 2
3
Fan speed (RPM)
1120
1280
1400
AIR delivery (CFM)
5500
6300
7000
Air Delivery (M3/min)
156
178
198
Noise Level (Dba)
54.5
58.8
68
Power Input (watts)
135
150
175
Current Measure (amps)
0.56
0.60
0.80
1
Speed Settings 2
3
Fan Speed (RPM)
1050
1260
1400
AIR Delivery (CFM)
3500
3700
4000
Air Delivery (M3/Min)
99
104
112
Noise Level (Dba)
52
54
56
Power Input (Watts)
85
95
105
0.39
0.42
0.50
REV201MG & REV203MG Specifications
Current Measure (Amps)
THE VENTILATION SPECIALISTS Ph: 1300 555 586 Fax: 1300 666 066 www.ventilationspecialists.com.au
79
TVS catalogue_Edition 2_Feb11_Layout 1 18/04/11 5:03 PM Page 80
Proudly Distributed by
Repelec (Aust) ABN 13 003 762 641
Phone: 1300 555 586 Fax: 1300 666 066 NEW SOUTH WALES 16 Rayben Street, Glendenning NSW 2761
NORTHERN TERRITORY Lot 3919 Hidden Valley Rd, Berrimah NT 0820
TASMANIA 51 Glen Dhu Street, Invermay TAS 7250
QUEENSLAND 17 Sudbury Street, Darra QLD 4076
VICTORIA 4 Enterprise Court, Mulgrave VIC 3170
TVS products available from:
SOUTH AUSTRALIA 95 Harrison Road, Dudley Park SA 5008
WESTERN AUSTRALIA 15 Mordaunt Circuit, Canning Vale WA 6155