V. 1601
1
APP EURO BATTERY CONNECTOR
V. 1601
2
Complete connectors
Euro 80 A
Amp.
Female/Male
Cable well
Article nr. Without handle
Article nr. With handle
80
Male
16 25 35 16 25 35 25 35 50 25 35 50 50 70 95 50 70 95
E804160009 E804250009 E804350009 E805160009 E805250009 E805350009 E164250009 E164350009 E164500009 E165250009 E165350009 E165500009 E324500009 E324700009 E324950009 E325500009 E325700009 E325950009
E804161009 E804251009 E804351009 E805161009 E805251009 E805351009 E164251009 E164351009 E164501009 E165251009 E165351009 E165501009 E324501009 E324701009 E324951009 E325501009 E325701009 E325951009
Female
Euro 160 A
160
Male
Female
Euro 320 A
320
Male
Female
Accessories: Handle Main Contacts-Auxiliary Contacts-Pilot Contacts Air Adapter-Coding pin-‘Dinloc’ Locking Plate
V. 1601
3
Anderson Power Products’ family of Euro Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and EN 1175-1. The connector design incorporates an innovative, cost effective contact carrier for ease of assembly.
Features • Sturdy advanced polymer housings PBT-PC alloy housings provides superior resistance to acids and temperature extremes
The connectors have a Degree of Protection of IP23 per IEC 60529. The acid resistance and temperature range of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are pure copper with silver plate for maximum conductivity.
• DIN 43589-1 voltage keying Dry-cell, wet-cell & universal keying plugs coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC
All materials meet RoHS requirements and are selected to ensure years of reliable service under adverse battery environments.
• Mating compatibility with connectors of other manufacturers APP “E” series connectors offer dimensional compatibility for air tube and auxiliary contacts over and above the DIN 43589-1 compatibility of housings and main contacts
EBC Connectors E80 Male DIN 43589 - 1
• Silver plated pure copper contacts For lowest voltage drop and superior performance
SPECIFICATIONS Electrical Current Rating (Amperes) * UL EN1175-1:1998 CSA Voltage Rating UL / CSA EN1175-1:1998 Wire Range - Power Contacts - AWG (mm²) - Auxiliary Contacts - AWG (mm²) Dielectric Withstanding Voltage (AC) Average Contact Resistance (micro-ohms) Operating Temperature (°C) (°F)
160 140 120 600 120 #8 to #2 (10 / 35) #18 to #14 (1.5/2.5) 2,200 65 -25° to 105° -13° to 221°
Mechanical Life a. No Load (mating cycles) b. Under Load (Hot Plug 5 mating cycles @96V) Average Mating / Unmating Force (lbf) (N) Degree of Protection Acid Resistance Contact Retention - minimum (lbf) (N) Air Tube Rating
>5000 200A 12 53 IP23 1.38g/cm³ 100 445 2 bar
Materials Housing Contacts
PBT/PC blend, glass filled Copper alloy, silver plate Steel, zinc chromate plate
Hardware *Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum carrying capacity is measured at 40°C/104°F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling.
V. 1601
4
ORDERING INFORMATION
TEMPERATURE CHARTS
Tooling Part Number Description 1387G3 Hydraulic tool for power contacts E160-36 Extraction tool Note: For tooling die information, see tooling chart on website.
E80 EBC Temperature Rise
DIMENSIONS Pin Contact Part Number EC80-1010 EC80-1016 EC80-1025 EC80-1035
-wiremm² 10 16 25 35
AWG #8 #6 #4 #2
-ØAmm² 6.1 8.4 10.9 12.4
In. 0.24 0.33 0.43 0.49
- ØBmm² 4.6 6.1 7.9 8.9
In. 0.18 0.24 0.31 0.35
E80 EBC Derating Curve (0.8 Derating per IEC 60512-3)
Upper Auxiliary Contact E80-32 upper auxiliary contact for 1.5mm²/2.5mm² (#18/#14 AWG)
Housing Side View
Lower Auxiliary Contact EH80-30 lower auxiliary contact for 1.5mm²/2.5mm² (#18/#14 AWG)
Housing Top view
Housing Front View
V. 1601
5
Anderson Power Products’ family of Euro Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and EN 1175-1. The connector design incorporates an innovative, cost effective contact carrier for ease of assembly.
Features • Sturdy advanced polymer housings PBT-PC alloy housings provides superior resistance to acids and temperature extremes
The connectors have a Degree of Protection of IP23 per IEC 60529. The acid resistance and temperature range of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are pure copper with silver plate for maximum conductivity.
• DIN 43589-1 voltage keying Dry-cell, wet-cell & universal keying plugs coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC
All materials meet RoHS equirements and are selected to ensure years of reliable service under adverse battery environments.
• Mating compatibility with connectors of other manufacturers APP “E” series connectors offer dimensional compatibility for air tube and auxiliary contactsover and above the DIN 43589-1 compatibility of housings and main contacts
EBC Connectors E80 Female DIN 43589 1
• Silver plated pure copper contacts For lowest voltage drop and superior performance
SPECIFICATIONS Electrical Current Rating (Amperes) * UL EN1175-1:1998 CSA Voltage Rating UL / CSA EN1175-1:1998 Wire Range - Power Contacts - AWG (mm²) - Auxiliary Contacts - AWG (mm²) Dielectric Withstanding Voltage (AC) Average Contact Resistance (micro-ohms) Operating Temperature (°C) (°F)
160 140 120 600 120 #8 to #2 (10 / 35) #18 to #14 (1.5/2.5) 2,200 65 -25° to 105° -13° to 221°
Mechanical Life a. No Load (mating cycles) b. Under Load (Hot Plug 5 mating cycles @96V) Average Mating / Unmating Force (lbf) (N) Degree of Protection Acid Resistance Contact Retention - minimum (lbf) (N) Air Tube Rating
>5000 200A 12 53 IP23 1.38g/cm³ 100 445 2 bar
Materials Housing Contacts
PBT/PC blend, glass filled Copper alloy, silver plate Steel, zinc chromate plate
Hardware *Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum carrying capacity is measured at 40°C/104°F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling
V. 1601
6
ORDERING INFORMATION
TEMPERATURE CHARTS
Tooling Part Number Description 1387G3 Hydraulic tool for power contacts E160-36 Extraction tool Note: For tooling die information, see tooling chart on website.
E80 EBC Temperature Rise
DIMENSIONS Socket Contact Part -wireNumber mm² AWG EC80-1110 EC80-1116 EC80-1125 EC80-1135
10 16 25 35
#8 #6 #4 #2
-ØAmm² 6.1 8.4 10.9 12.4
In. 0.24 0.33 0.43 0.49
- ØBmm² 4.6 6.1 7.9 8.9
In. 0.18 0.24 0.31 0.35
E80 EBC Derating Curve (0.8 Derating per IEC 60512-3)
Upper Auxiliary Contact E80-33 upper auxiliary contact for 1.5mm²/2.5mm² (#18/#14 AWG)
Housing Side View Lower Auxiliary Contact E80-31 lower auxiliary contact for 1.5mm²/2.5mm² (#18/#14 AWG)
Housing Top view Housing Front View
V. 1601
7
Anderson Power Products’ family of Euro Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and EN 1175-1. The connector design incorporates an innovative, cost effective contact carrier for ease of assembly.
Features • Sturdy advanced polymer housings PBT-PC alloy housings provides superior resistance to acids and temperature extremes
The connectors have a Degree of Protection of IP23 per IEC 60529. The acid resistance and temperature range of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are pure copper with silver plate for maximum conductivity.
• DIN 43589-1 voltage keying Dry-cell, wet-cell & universal keying plugs coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC
All materials meet RoHS equirements and are selected to ensure years of reliable service under adverse battery environments.
• Mating compatibility with connectors of other manufacturers APP “E” series connectors offer dimensional compatibility for air tube and auxiliary contactsover and above the DIN 43589-1 compatibility of housings and main contacts
EBC Connectors E16 Male DIN 43589 - 1
• Silver plated pure copper contacts For lowest voltage drop and superior performance
SPECIFICATIONS Electrical Current Rating (Amperes) * UL EN1175-1:1998 CSA Voltage Rating UL / CSA EN1175-1:1998 Wire Range - Power Contacts - AWG (mm²) - Auxiliary Contacts - AWG (mm²) Dielectric Withstanding Voltage (AC) Average Contact Resistance (micro-ohms) Operating Temperature (°C) (°F)
220 190 160 600 150 #6 to #1/0 (16 / 50) #1 to #10 (4/6) 2,200 55 -25° to 105° -13° to 221°
Mechanical Life a. No Load (mating cycles) b. Under Load (Hot Plug 5 mating cycles @96V) Average Mating / Unmating Force (lbf) (N) Degree of Protection Acid Resistance Contact Retention - minimum (lbf) (N) Air Tube Rating
>5000 400A 12 53 IP23 1.38g/cm³ 100 445 2 bar
Materials Housing Contacts
PBT/PC blend, glass filled Copper alloy, silver plate Steel, zinc chromate plate
Hardware *Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum carrying capacity is measured at 40°C/104°F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling
V. 1601
8
ORDERING INFORMATION
TEMPERATURE CHARTS
Tooling Part Number Description 1387G3 Hydraulic tool for power contacts E160-36 Extraction tool Note: For tooling die information, see tooling chart on website.
E16 EBC Temperature Rise
DIMENSIONS Pin Contact Part Number EC160-1016 EC160-1025 EC160-1035 EC160-1050
-wiremm² 16 25 35 50
AWG #6 #4 #2 #1/0
-ØAmm² 8.4 11.0 12.5 14.5
In. 0.33 0.43 0.49 0.57
- ØBmm² 6.0 8.0 9.0 11.0
In. 0.24 0.31 0.35 0.43
E16 EBC Derating Curve (0.8 Derating per IEC 60512-3)
Upper Auxiliary Contact E160-32 upper auxiliary contact for 4mm²/ (#12AWG)
Housing Side View Lower Auxiliary Contact E160-12 lower auxiliary contact for 65mm² (#10AWG)
Handle/Lever Assembly/Latch
Housing Front View
Housing Top view
V. 1601
9
Anderson Power Products’ family of Euro Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and EN 1175-1. The connector design incorporates an innovative, cost effective contact carrier for ease of assembly.
Features • Sturdy advanced polymer housings PBT-PC alloy housings provides superior resistance to acids and temperature extremes
The connectors have a Degree of Protection of IP23 per IEC 60529. The acid resistance and temperature range of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are pure copper with silver plate for maximum conductivity.
• DIN 43589-1 voltage keying Dry-cell, wet-cell & universal keying plugs coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC
All materials meet RoHS equirements and are selected to ensure years of reliable service under adverse battery environments.
• Mating compatibility with connectors of other manufacturers APP “E” series connectors offer dimensional compatibility for air tube and auxiliary contactsover and above the DIN 43589-1 compatibility of housings and main contacts
EBC Connectors E16 Female DIN 43589 1
• Silver plated pure copper contacts For lowest voltage drop and superior performance
SPECIFICATIONS Electrical Current Rating (Amperes) * UL EN1175-1:1998 CSA Voltage Rating UL / CSA EN1175-1:1998 Wire Range - Power Contacts - AWG (mm²) - Auxiliary Contacts - AWG (mm²) Dielectric Withstanding Voltage (AC) Average Contact Resistance (micro-ohms) Operating Temperature (°C) (°F)
220 190 160 600 150 #6 to #1/0 (16 / 50) #1 to #10 (4/6) 2,200 55 -25° to 105° -13° to 221°
Mechanical Life a. No Load (mating cycles) b. Under Load (Hot Plug 5 mating cycles @96V) Average Mating / Unmating Force (lbf) (N) Degree of Protection Acid Resistance Contact Retention - minimum (lbf) (N) Air Tube Rating
>5000 400A 12 53 IP23 1.38g/cm³ 100 445 2 bar
Materials Housing Contacts
PBT/PC blend, glass filled Copper alloy, silver plate Steel, zinc chromate plate
Hardware *Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum carrying capacity is measured at 40°C/104°F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling
V. 1601
10
ORDERING INFORMATION
TEMPERATURE CHARTS
Tooling Part Number Description 1387G3 Hydraulic tool for power contacts E160-36 Extraction tool Note: For tooling die information, see tooling chart on website.
E16 EBC Temperature Rise
DIMENSIONS Pin Contact Part Number EC160-1116 EC160-1125 EC160-1135 EC160-1150
-wiremm² 16 25 35 50
AWG #6 #4 #2 #1/0
-ØAmm² 8.4 11.0 12.5 14.5
In. 0.33 0.43 0.49 0.57
- ØBmm² 6.0 8.0 9.0 11.0
In. 0.24 0.31 0.35 0.43
E16 EBC Derating Curve (0.8 Derating per IEC 60512-3)
Upper Auxiliary Contact E160-33 upper auxiliary contact for 4mm²/ (#12AWG)
Housing Side View Lower Auxiliary Contact E160-13 lower auxiliary contact for 65mm² (#10AWG)
Handle/Lever Assembly/Latch
Housing Front View
Housing Top view
V. 1601
11
Anderson Power Products’ family of Euro Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and EN 1175-1. The connector design incorporates an innovative, cost effective contact carrier for ease of assembly.
Features • Sturdy advanced polymer housings PBT-PC alloy housings provides superior resistance to acids and temperature extremes
The connectors have a Degree of Protection of IP23 per IEC 60529. The acid resistance and temperature range of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are pure copper with silver plate for maximum conductivity.
• DIN 43589-1 voltage keying Dry-cell, wet-cell & universal keying plugs coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC
All materials meet RoHS equirements and are selected to ensure years of reliable service under adverse battery environments.
• Mating compatibility with connectors of other manufacturers APP “E” series connectors offer dimensional compatibility for air tube and auxiliary contactsover and above the DIN 43589-1 compatibility of housings and main contacts
EBC Connectors E32 Male DIN 43589 - 1
• Silver plated pure copper contacts For lowest voltage drop and superior performance
SPECIFICATIONS Electrical Current Rating (Amperes) * UL EN1175-1:1998 CSA Voltage Rating UL / CSA EN1175-1:1998 Wire Range - Power Contacts - AWG (mm²) - Auxiliary Contacts - AWG (mm²) Dielectric Withstanding Voltage (AC) Average Contact Resistance (micro-ohms) Operating Temperature (°C) (°F)
340 300 260 600 150 #1/0 to #4/0 (50/95) #12 to #10 (4/6) 2,200 30 -25° to 105° -13° to 221°
Mechanical Life a. No Load (mating cycles) b. Under Load (Hot Plug 5 mating cycles @96V) Average Mating / Unmating Force (lbf) (N) Degree of Protection Acid Resistance Contact Retention - minimum (lbf) (N) Air Tube Rating
>5000 800A 12 53 IP23 1.38g/cm³ 100 445 2 bar
Materials Housing Contacts
PBT/PC blend, glass filled Copper alloy, silver plate Steel, zinc chromate plate
Hardware *Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum carrying capacity is measured at 40°C/104°F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling
V. 1601
12
ORDERING INFORMATION
TEMPERATURE CHARTS
Tooling Part Number Description 1387G3 Hydraulic tool for power contacts E160-36 Extraction tool Note: For tooling die information, see tooling chart on website.
E32 EBC Temperature Rise
DIMENSIONS Pin Contact Part Number EC320-1050 EC320-1070 EC320-1095
-wiremm² 50 70 95
AWG #1/0 #2/0 #3/0
-ØAmm² 14.5 17.0 19.8
In. 0.57 0.67 0.78
- ØBmm² 11.0 13.0 15.0
In. 0.43 0.51 0.59
-Cmm² 65.5 65.5 70.5
in. 2.58 2.58 2.78 E32 EBC Derating Curve (0.8 Derating per IEC 60512-3)
Upper Auxiliary Contact E320-34 upper auxiliary contact for 4mm²/ (#12AWG)
Lower Auxiliary Contact E160-12 lower auxiliary contact for 65mm² (#10AWG)
Handle/Lever Assembly/Latch
Housing Front View
Housing Side View
Housing Top view
V. 1601
13
Anderson Power Products’ family of Euro Battery Connectors (EBC) exceeds all the requirements of DIN 43589-1 and EN 1175-1. The connector design incorporates an innovative, cost effective contact carrier for ease of assembly.
Features • Sturdy advanced polymer housings PBT-PC alloy housings provides superior resistance to acids and temperature extremes
The connectors have a Degree of Protection of IP23 per IEC 60529. The acid resistance and temperature range of the PBT-PC housing exceeds the requirements of EN 1175-1. Contacts are pure copper with silver plate for maximum conductivity.
• DIN 43589-1 voltage keying Dry-cell, wet-cell & universal keying plugs coded for 24 / 36 / 48 / 72 / 80 & 96 volts DC
All materials meet RoHS equirements and are selected to ensure years of reliable service under adverse battery environments.
• Mating compatibility with connectors of other manufacturers APP “E” series connectors offer dimensional compatibility for air tube and auxiliary contactsover and above the DIN 43589-1 compatibility of housings and main contacts
EBC Connectors E32 Female DIN 43589 1
• Silver plated pure copper contacts For lowest voltage drop and superior performance
SPECIFICATIONS Electrical Current Rating (Amperes) * UL EN1175-1:1998 CSA Voltage Rating UL / CSA EN1175-1:1998 Wire Range - Power Contacts - AWG (mm²) - Auxiliary Contacts - AWG (mm²) Dielectric Withstanding Voltage (AC) Average Contact Resistance (micro-ohms) Operating Temperature (°C) (°F)
340 300 260 600 150 #1/0 to #4/0 (50/95) #12 to #10 (4/6) 2,200 30 -25° to 105° -13° to 221°
Mechanical Life a. No Load (mating cycles) b. Under Load (Hot Plug 5 mating cycles @96V) Average Mating / Unmating Force (lbf) (N) Degree of Protection Acid Resistance Contact Retention - minimum (lbf) (N) Air Tube Rating
>5000 800A 12 53 IP23 1.38g/cm³ 100 445 2 bar
Materials Housing Contacts
PBT/PC blend, glass filled Copper alloy, silver plate Steel, zinc chromate plate
Hardware *Current derating curves must be observed as current capacity will vary dependent on wire cross section and ambient temperature. Maximum carrying capacity is measured at 40°C/104°F using the maximum wire cross section permissible, crimped to contacts using APP recommended tooling
V. 1601
14
ORDERING INFORMATION
TEMPERATURE CHARTS
Tooling Part Number Description 1387G3 Hydraulic tool for power contacts E160-36 Extraction tool Note: For tooling die information, see tooling chart on website.
E32 EBC Temperature Rise
DIMENSIONS Pin Contact Part Number EC320-1150 EC320-1170 EC320-1195
-wiremm² 50 70 95
AWG #1/0 #2/0 #3/0
-ØAmm² 14.5 17.0 19.8
In. 0.57 0.67 0.78
- ØBmm² 11.0 13.0 15.0
In. 0.43 0.51 0.59
-Cmm² 65.5 65.5 70.5
in. 2.58 2.58 2.78 E32 EBC Derating Curve (0.8 Derating per IEC 60512-3)
Upper Auxiliary Contact E320-35 upper auxiliary contact for 4mm²/ (#12AWG)
Lower Auxiliary Contact E160-13 lower auxiliary contact for 65mm² (#10AWG)
Handle/Lever Assembly/Latch
Housing Front View
Housing Side View
Housing Top view