Unity Pro V6.0 ID Quantum Evolutions M340 Evolutions Improved support of online changes Improved OFS tag management Improved application services Better support of Third-party Applications Integration of LL984 language
2
ID Card ● Unity Pro V6.0
Package content
● Supported OS
XP 32bits
Vista Seven 32bits
Seven 64bits
V6.0
X
X
X
● ●
Windows XP 32 bits Windows Vista 32 Bits
●
Windows 7 32 and 64 bits
DTM EtherNet IP
V1.0
X
X
X
●
Unity Pro can be run with USER Right - Nevertheless Administration right is mandatory for installation and to Update DTM catalog.
DTM Psx RIO
V1.0
X
X
X
X
X
x
Modbus Serial
V1.9 IE36
V2.1 IE11
V3.1 IE11
USB driver
V1.5 IE20
V2.2 IE12
V3.2 IE12
UTW driver
V1.10 IE22
V2.2 IE12
V3.2 IE12
XIP driver
V1.11 IE24
V2.3 IE13
V3.3 IE13
PCIway driver
V1.1 IE09
V2.1 IE11
V3.1 IE11
USB-Fip Driver
V1.0 IE06
V2.2 IE12
V3.3 IE13
V1.1
X
X
X
CD Unity Loader
V2.2
X
X
X
CD ACS
V5.5
X
X
X
CD EIP Tool
V1.1
X
X
X
DVD Documentation
V6.0
X
X
X
● Installation includes : ●
●
Installation of DTMs for NOC modules and Ethernet RIO - An update of the DTM catalog is needed before the first use. Installation of Schneider Electric Software Update - To receive automatic notification for Unity Pro updates
DVD Unity Pro:
Drivers:
SESU
Installed with Unity Pro installation Schneider Electric
3
Quantum Evolutions ● Quantum Ethernet RIO architectures ● Easy configuration of Ethernet RIO architectures ● ● ●
Role Name for Ethernet Drop Automatic configuration through DHCP server Control of IP information (addresses compliance, gateways, subnet mask ...)
● Integration of remote PRA configurations in master application managing the IO scanner
Schneider Electric
4
Quantum Evolutions ● Respect of legacy platforms behavior for the migration. ● Reset % M on start from STOP to RUN by configuring a project option
● New module to extend communication distance between S908 drops ● New fiber optic module repeater : 140 NRP 954 00 ● ● ●
The 140 NRP 954 00 fiber optical repeater module provides communication between two or more RIO nodes or segments of networks over a fiber optic medium. Each repeater contains one electrical RIO interface and two fiber optic transceivers. This module allows a peer to peer communication over a distance of 2 to 3 km and a maximum of thirty Km using bus or self healing ring topology with a maximum of 12 repeaters.Unity Pro V6.0
Number of channels: Transmission speed per channel: Module cycle time per channel: SSI Capture inputs: IEC 61131-2 conformity: Absolute SSI encoder: Reflex outputs: SSI encoder functions :
Schneider Electric
3 100 kHz, 200 kHz, 500 kHz, 1 MHz 1 ms Two digital inputs Type3 24VDC 19.2 to 30 VDC One 24VDC push-pull per channel Communication, Modulo, Capture, Compare
6
Improved Support Of Online Changes ● The following actions are allowed in RUN mode: ● Import / Export of DFB, DDT, EDT ● Creating or removing variable without limitation ● Ability to prepare a modification online and activate it when needed
● Indicator in the status bar to warn about compacting the memory
Schneider Electric
7
Improved OFS Tag Management ● Continuity of communication with OFS during online changes ● Size reduction of data dictionary by exchanging only the necessary variables Note: These two options need the use of OFS version 3.35
Schneider Electric
8
Improved Application Services ● Operation and Maintenance: ● Complete refoundation of Search/Replace Tool ●
Direct access from the menu bar
●
Find exact location of the required variable
●
Simplified cross-references window.
Schneider Electric
●Automatic bookmark creation for quick access to the previous searches
9
Improved Application Services ● Operation and Maintenance: ● Support unlocated data transfer after a complete application build ●
New data file format,
●
Add new element in structure and restore data file
dtx ● Animation tables with setting can be saved ●
Set values can be saved with application, exported and imported then applied
Schneider Electric
●Populates Force value from variables forcing state
10
Improved Application Services ● Operation and Maintenance: ● Update initial values from the controller to the local application ●
Variable with initial value and save attribute can be updated with current value
●
Local application can then be simply updated keeping it unspoiled
Schneider Electric
11
Improved Application Services ● Operation and Maintenance: ● Better resolution for Trends ●
sampling trending adjustable up to 100 ms
●
Definition up to 1 pixel to display twice as much information
Bit second Unity Pro: V5.0 Sampling: 1s Definition: 2 pixels
Period 20 ms
Minimum sampling time depend on the communication bandwidth Bit second Unity Pro: V6.0 Sampling: 100ms Definition:1 pixels
Schneider Electric
Period 20ms
12
Improved Application Services ● Design: ● Import of a section in the desired location
● Symbolization of extracted bits for “Device DDT” and DTM structures DROP_1.CRA_DIAGNOSTIC.0
DROP_1.GLOBAL_IO_HEALTH
● Improved program readability through explicit default naming of FFB ●
Before V6.0
Schneider Electric
● V6.0
13
Improved Application Services ● Design ● New SATURATION function to control the precision of a real value Desired Precision tested Value
Error when Value > Limit Value Limit Value for desired Precision
● New HSBY_SWAP function to program primary / standby swap
● Improved performances for BIT_TO_WORD, WORD_TO_BIT and SEL functions ●
40% cycle time reduction in applications using massively these instructions 14
Improved Application Services ● Design ● Locking and unlocking several DFB, selected from Data Properties window
● Display the list of modified sections when generating the application
Schneider Electric
●Added protection of section for subroutines (SR)
15
Improved Application Services ● Design ● No obligation to connect structure on DFB pins when it is not needed ● Before V6.0
● V6.0
In case structures or variables are not connected, values are set to zero or empty for strings.
● Import of DCF description files from Hardware Catalog Manager ● ●
Allow the support of TM5 and TM7 IO modules on M340 TM5 and TM7 DTMs are not compatible with Unity Pro…
Schneider Electric
16
Improved Application Services ● Ergonomics ● In Ladder language activation of the mixed display mode is taken into account for all LD sections
Schneider Electric
17
Improved Application Services ● Ergonomics ● Possibility to not prefix Advantys variables with the island name
When disabled, user is responsible for the uniqueness of the variables
Schneider Electric
18
Improved Application Services ● Ergonomics ● Possibility to modify animation colors of program editors ● From configuration files in Unity pro directory
● File edit with text editor (note pad)
(Magenta) (Cyan)
● Color coded in RGB mode
Schneider Electric
● Modifications take into account at editor openingV6.0
19
Improved Application Services ● General ● New zipped export format ZEF includes DTM configuration ●
The new zipped export format ZEF includes the DTM device configuration used in the DTM browser. It allows the complete restitution of the project. Note: To be able to modify the configuration of DTM devices, needed DTMs must be installed on the PC where the application is imported.
● Viewing application information in the tooltip and properties of STU file
Schneider Electric
20
Better support Of Third-party Applications ● Better integration of third-party tools ● Launch with context from Unity Pro ●
It is now possible to launch a third party application giving the opened project as argument
● Opening of section to a given location row / column ●
Third party application can now open a section in a specific location
● Additional information in export file ● ●
CANopen topology and DTM topology Interface Description for EF and EFB
Schneider Electric
21
Integration Of LL984 Language ● Support of Modsoft, Concept, ProWorx NxT and ProWorx32 applications ● Hardware configuration import ● ●
Fully automatic via mapping tables Customizable with partial import wizard
● Execution on Quantum platforms ●
Support of all Modbus data access function calls
● Ensure LL984 execution behavior ●
Network execution by column
Schneider Electric
22
Integration Of LL984 Language ● Keep LL984 structure ●
Segments and networks
●
Equation networks available Using IEC ST functions
●State Flow and Power Flow animation
●Multiple network monitoring and editing
Schneider Electric
23
Integration Of LL984 Language ● Support of original LL984 functionalities with same look and feel Symbols, descriptors, short and long comments Max. 7 rows of documentation above each reference in the LL984 instruction Keep register information as documentation Programming with mnemonics instructions quickly Button bar & Quick bar to access all LL984 4 user definable views