Underfloor trunking systems Amendment to catalogue Cable management + Trunking system solutions

Underfloor trunking systems Amendment to catalogue “Cable management + Trunking system solutions 2015|2016” Help your customers to stay ahead of the...
Author: Alaina Clark
1 downloads 0 Views 26MB Size
Underfloor trunking systems Amendment to catalogue “Cable management + Trunking system solutions 2015|2016”

Help your customers to stay ahead of the game! The face of modern office architecture is shaped by large glass frontages and expansive interior areas, and classic external walls and internal walls are increasingly on their way out. This means that electrical engineers need to go ever further “underground” if they are to set up a capable, high-performance electrical infrastructure. At Hager, we wish to continue to offer our active support with this in the future – and this is why we have significantly expanded our range of underfloor trunking systems.

2

The right system for every floor The new underfloor trunking systems from Hager offer the perfect solution for every type of floor and for every requirement relating to electrotechnical installations – whether as a floor-mounted trunking system, a screed-covered trunking system, a trunking system that fits flush with the surface of the screed, systems for double floors or systems for cavity floors. Alongside standard systems, we also continue to offer customised project solutions for special requirements, e. g. systems for heavy-duty loads.

Better than ever: the new tehalit.BKB As part of the ongoing improvements, we have also optimised some of our more successful solutions: for example, the tehalit.BKB system is now even easier to install and even more practical to use. It is now available with three different variants of the upper part, which feature footfall sound insulation and can be ordered separately from the lower part. Of course, we still offer service posts and workplace connection systems that deliver elegant transitions between floor and workplace. Help your customers to be happy without walls – with underfloor trunking systems from Hager!

3

4

04 05 06 07 08 09 10

Raised floor and cavity floor trunking systems electraplan.DB-HB | Cable outlets | Flat chains and round chains Service units and installation units electraplan.VE-EE

Device casings and installation devices electraplan.GB-EG

Service posts tehalit.DAP | tehalit.DEP

Workplace connection system Connecting modules | Universal connection blocks | Mounted and installed connection units Technical information General technical information | FAQ

Appendix Alphanumeric search index | CE installation instructions | Declaration of conformity

electraplan.UK tehalit.BKB electraplan.BK electraplan.AK On-the-floor trunking

On-the-floor trunking system electraplan.AK | On-the-floor trunking

48

106

electraplan.DB-HB

03

Screed-flush trunking systems tehalit.BKB | electraplan.BK

130

electraplan.VE-EE

02

6

154

216

electraplan.GB-EG

Screed-covered trunking systems electraplan.UK

tehalit.DAP|DEP

01

Page

244

Workplace connection system

Summary

254

Technical information

Chapter

262

Appendix



284 5

electraplan.UK

Screed-covered trunking systems

electraplan.UK The quick installation system for every application The flexible solution for all types of screed delivers impressive and practical installation advantages: Pre-assembled underfloor trunking enables quick and easy installation at the construction site, and the snapped-on trunking covers can easily be taken off before the screed is poured to allow simple insertion of the lines from above – rendering complex cable drawing-in processes completely unnecessary. And because all underfloor trunking and junction boxes are made of zinc-plated steel plate in accordance with DIN EN 10327, the entire system is perfectly protected against corrosion.

electraplan.UK

electraplan.UK System overview

8

Trunking overview

9

Screed-covered trunking system, trunking width 190 mm

10

Screed-covered trunking system, trunking width 240 mm

12

Screed-covered trunking system, trunking width 340 mm

14

Universal junction boxes

16

Universal junction boxes, accessories

19

Formwork elements for service units and height adjustable cassettes

21

Order number system

22

Technical information

23

7

electraplan.UK

electraplan.UK System overview 2

5

1 1 3

6

1

1

8

4

7

9

electraplan.UK 1 Basic profile comprising Upper and lower part 2 Clamp 3 Bracket 4  End bracket 5 Vertical elbow 6 Universal junction box with foil casing 7 Universal junction box with steel plate casing 8 Fitting frame 9 Pipe inlet

8

Technical changes reserved

Trunkings

Trunking width mm

Trunking height mm

Variant

Compartment dimensions mm

Usable Max. Line cross-section allocation cm² Ø 11 mm, half full

UK1900282 UK1900283 UK1900382 UK1900383 UK1900482 UK1900483

190 190 190 190 190 190

28 28 38 38 48 48

2 compartments 3 compartments 2 compartments 3 compartments 2 compartments 3 compartments

75 / 115 60 / 70 / 60 75 / 115 60 / 70 / 60 75 / 115 60 / 70 / 60

53.2 53.2 72.2 72.2 91.2 91.2

21 (8 / 13) 20 (6 / 8 / 6) 29 (11 / 18) 28 (9 / 10 / 9) 36 (14 / 22) 35 (11 / 13 / 11)

10 10 10 10 10 10

UK2400282 UK2400283 UK2400382 UK2400383 UK2400482 UK2400483

240 240 240 240 240 240

28 28 38 38 48 48

2 compartments 3 compartments 2 compartments 3 compartments 2 compartments 3 compartments

100 / 140 85 / 70 / 85 100 / 140 85 / 70 / 85 100 / 140 85 / 70 / 85

67.2 67.2 91.2 91.2 115.2 115.2

27 (11 / 16) 26 (9 / 8 / 9) 36 (15 / 21) 36 (13 / 10 / 13) 46 (19 / 27) 45 (16 / 13 / 16)

12 12 12 12 12 12

UK3400282 UK3400283 UK3400382 UK3400383 UK3400482 UK3400483

340 340 340 340 340 340

28 28 38 38 48 48

2 compartments 3 compartments 2 compartments 3 compartments 2 compartments 3 compartments

140 / 200 115 / 110 / 115 140 / 200 115 / 110 / 115 140 / 200 115 / 110 / 115

95.2 95.2 129.2 129.2 163.2 163.2

39 (16 / 23) 38 (13 / 12 / 13) 52 (21 / 31) 53 (18 / 17 / 18) 66 (27 / 39) 65 (22 / 21 / 22)

14 14 14 14 14 14

Technical changes reserved

Page

9

electraplan.UK

electraplan.UK Trunking overview

electraplan.UK

electraplan.UK Screed-covered trunking system, trunking width 190 mm - Underfloor trunking UK compliant with DIN EN 50085-1 and 2-2 for screed-covered installation, for installation on bare floor - Line routing is made quick and easy thanks to the removable covers.

Standard length 2000 mm Material Galvanised sheet metal, Galvanised in accordance with DIN EN 10327 Material thickness Upper part 1.25 mm Lower part 1.0 mm

Basic profile Sheet metal

Trunking height mm

UK190282

UK190282 PU 2 m

28

UK190283

UK190283 PU 2 m

28

UK190382

UK190382 PU 2 m

38

UK190383

UK190383 PU 2 m

38

UK190482

UK190482 PU 2 m

48

UK190483

UK190483 PU 2 m

48

10

Technical changes reserved

electraplan.UK Clamp Sheet metal

Bracket Sheet metal

End bracket Sheet metal

Vertical elbow Sheet metal

Expansion bushing Sheet metal

UKS190280 PU 20 pc

UKB190280 PU 20 pc

UKE190280 PU 20 pc

UKK190282 PU 1 pc

UKM190280 PU 20 pc

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

UKS190280 PU 20 pc

UKB190280 PU 20 pc

UKE190280 PU 20 pc

UKK190283 PU 1 pc

UKM190280 PU 20 pc

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

Dim. a = 28 mm Dim. b = 190 mm

UKS190380 PU 20 pc

UKB190380 PU 20 pc

UKE190380 PU 20 pc

UKK190382 PU 1 pc

UKM190380 PU 20 pc

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

UKS190380 PU 20 pc

UKB190380 PU 20 pc

UKE190380 PU 20 pc

UKK190383 PU 1 pc

UKM190380 PU 20 pc

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

Dim. a = 38 mm Dim. b = 190 mm

UKS190480 PU 20 pc

UKB190480 PU 20 pc

UKE190480 PU 20 pc

UKK190482 PU 1 pc

UKM190480 PU 20 pc

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

UKS190480 PU 20 pc

UKB190480 PU 20 pc

UKE190480 PU 20 pc

UKK190483 PU 1 pc

UKM190480 PU 20 pc

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Dim. a = 48 mm Dim. b = 190 mm

Technical changes reserved

11

electraplan.UK

electraplan.UK Screed-covered trunking system, trunking width 240 mm - Underfloor trunking UK compliant with DIN EN 50085-1 and 2-2 for screed-covered installation, for installation on bare floor - Line routing is made quick and easy thanks to the removable upper parts.

Standard length 2000 mm Material Galvanised sheet metal, Galvanised in accordance with DIN EN 10327 Material thickness Upper part 1.25 mm Lower part 1.0 mm

Basic profile Sheet metal

Trunking height mm

UK240282

UK240282 VPE 2 m

28

UK240283

UK240283 VPE 2 m

28

UK240382

UK240382 VPE 2 m

38

UK240383

UK240383 VPE 2 m

38

UK240482

UK240482 VPE 2 m

48

UK240483

UK240483 VPE 2 m

48

12

Technical changes reserved

electraplan.UK Clamp Sheet metal

Bracket Sheet metal

End bracket Sheet metal

Vertical elbow Sheet metal

Expansion bushing Sheet metal

UKS240280 PU 20 pc

UKB240280 PU 20 pc

UKE240280 PU 20 pc

UKK240282 PU 1 pc

UKM240280 PU 20 pc

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

UKS240280 PU 20 pc

UKB240280 PU 20 pc

UKE240280 PU 20 pc

UKK240283 PU 1 pc

UKM240280 PU 20 pc

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

Dim. a = 28 mm Dim. b = 240 mm

UKS240380 PU 20 pc

UKB240380 PU 20 pc

UKE240380 PU 20 pc

UKK240382 PU 1 pc

UKM240380 PU 20 pc

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

UKS240380 PU 20 pc

UKB240380 PU 20 pc

UKE240380 PU 20 pc

UKK240383 PU 1 pc

UKM240380 PU 20 pc

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

Dim. a = 38 mm Dim. b = 240 mm

UKS240480 PU 20 pc

UKB240480 PU 20 pc

UKE240480 PU 20 pc

UKK240482 PU 1 pc

UKM240480 PU 20 pc

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

UKS240480 PU 20 pc

UKB240480 PU 20 pc

UKE240480 PU 20 pc

UKK240483 PU 1 pc

UKM240480 PU 20 pc

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Dim. a = 48 mm Dim. b = 240 mm

Technical changes reserved

13

electraplan.UK

electraplan.UK Screed-covered trunking system, trunking width 340 mm - Underfloor trunking UK compliant with DIN EN 50085-1 and 2-2 for screed-covered installation, for installation on bare floor - Line routing is made quick and easy thanks to the removable upper parts.

Standard length 2000 mm Material Galvanised sheet metal, Galvanised in accordance with DIN EN 10327 Material thickness Upper part 1.25 mm Lower part 1.0 mm

Basic profile Sheet metal

Trunking height mm

UK340282

UK340282 PU 2 m

28

UK340283

UK340283 PU 2 m

28

UK340382

UK340382 PU 2 m

38

UK340383

UK340383 PU 2 m

38

UK340482

UK340482 PU 2 m

48

UK340483

UK340483 PU 2 m

48

14

Technical changes reserved

electraplan.UK Clamp Sheet metal

Bracket Sheet metal

End bracket Sheet metal

Vertical elbow Sheet metal

Expansion bushing Sheet metal

UKS340280 PU 20 pc

UKB340280 PU 20 pc

UKE340280 PU 20 pc

UKK340282 PU 1 pc

UKM340280 PU 20 pc

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

UKS340280 PU 20 pc

UKB340280 PU 20 pc

UKE340280 PU 20 pc

UKK340283 PU 1 pc

UKM340280 PU 20 pc

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

Dim. a = 28 mm Dim. b = 340 mm

UKS340380 PU 20 pc

UKB340380 PU 20 pc

UKE340380 PU 20 pc

UKK340382 PU 1 pc

UKM340380 PU 20 pc

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

UKS340380 PU 20 pc

UKB340380 PU 20 pc

UKE340380 PU 20 pc

UKK340383 PU 1 pc

UKM340380 PU 20 pc

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

Dim. a = 38 mm Dim. b = 340 mm

UKS340480 PU 20 pc

UKB340480 PU 20 pc

UKE340480 PU 20 pc

UKK340482 PU 1 pc

UKM340480 PU 20 pc

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

UKS340480 PU 20 pc

UKB340480 PU 20 pc

UKE340480 PU 20 pc

UKK340483 PU 1 pc

UKM340480 PU 20 pc

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Dim. a = 48 mm Dim. b = 340 mm

Technical changes reserved

15

electraplan.UK

electraplan.UK Universal junction boxes - Underfloor universal junction box in accordance with DIN EN 50085-1 and -2-2 - With internal stepless height adjustment - With bottom plate and flexible transparent casing for installation in the screed layer

- Connection of underfloor trunking could not be easier – simply cut the foil with scissors or a knife - Suitable for the mounting of installation units via a fitting frame (to be ordered separately)

- With factory-fitted footfall noise insulation and height-adjustment set screws - Height-adjustable from the minimum installation height

Universal junction box with bottom plate, size 2 Properties: - For max. 4 sets of trunking with a nominal width of 240 mm

Designation

UDB2120170

Height adjustment range [mm]

Underfloor box with bottom plate size 2 50-80 Underfloor box with bottom plate size 2 75-125 Underfloor box with bottom plate size 2 120-170 Underfloor box with bottom plate size 2 165-215 Underfloor box with bottom plate size 2 215-265

PU

8 5 9 5 5

Order no.

UDB2050080 UDB2075125 UDB2120170 UDB2165215 UDB2215265

Universal junction box with bottom plate, size 3 Properties: - For max. 4 sets of trunking with a nominal width of 340 mm

Designation

UDB3120170

16

Height adjustment range [mm]

Underfloor box with bottom plate size 3 50-80 Underfloor box with bottom plate size 3 75-125 Underfloor box with bottom plate size 3 120-170 Underfloor box with bottom plate size 3 165-215 Underfloor box with bottom plate size 3 215-265

Technical changes reserved

PU

8 5 9 5 5

Order no.

UDB3050080 UDB3075125 UDB3120170 UDB3165215 UDB3215265

- Underfloor universal junction box in accordance with DIN EN 50085-1 and -2-2 - With internal stepless height adjustment - With bottom plate and flexible transparent casing for installation in the screed layer

- Connection of underfloor trunking could not be easier – simply cut the foil with scissors or a knife - Suitable for the mounting of installation units via a fitting frame (to be ordered separately)

- With factory-fitted footfall noise insulation and height-adjustment set screws - Height-adjustable from the minimum installation height

Universal junction box with retaining tabs, size 2 Properties: - For max. 4 sets of trunking with a nominal width of 240 mm

Designation

UDH2120170

Height adjustment range [mm]

Underfloor box with retaining tabs size 2 50-80 Underfloor box with retaining tabs size 2 75-125 Underfloor box with retaining tabs size 2 120-170 Underfloor box with retaining tabs size 2 165-215 Underfloor box with retaining tabs size 2 215-265

PU

8 5 9 5 5

Order no.

UDH2050080 UDH2075125 UDH2120170 UDH2165215 UDH2215265

Universal junction box with retaining tabs, size 3 Properties: - For max. 4 sets of trunking with a nominal width of 340 mm

Designation

UDH3120170

Height adjustment range [mm]

Underfloor box with retaining tabs size 3 50-80 Underfloor box with retaining tabs size 3 75-125 Underfloor box with retaining tabs size 3 120-170 Underfloor box with retaining tabs size 3 165-215 Underfloor box with retaining tabs size 3 215-265

Technical changes reserved

PU

8 5 9 5 5

Order no.

UDH3050080 UDH3075125 UDH3120170 UDH3165215 UDH3215265

17

electraplan.UK

electraplan.UK Universal junction boxes

electraplan.UK

electraplan.UK Universal junction boxes - Underfloor universal junction box in accordance with DIN EN 50085-1 and -2-2 - With internal stepless height adjustment - With bottom plate and sheet metal casing for installation in the screed layer

- Suitable for the mounting of installation units via a fitting frame (to be ordered separately) - The sheet metal walls have a perforation matching the cross-sectional pattern of the underfloor trunking UK.

- Minimum installation height 70 mm - Height adjustment above 120 mm only possible with levelling frame

Universal junction box with sheet metal casing size 3 Properties: - For max. 4 sets of trunking with a nominal width of 340 mm

Designation

UDS3070120

18

Height adjustment range [mm]

Underfloor box, sheet metal, size 3 70-120

Technical changes reserved

PU

3

Order no.

UDS3070120

Material: Galvanised sheet metal, Galvanised in accordance with DIN EN 10327

electraplan.UK

electraplan.UK Universal junction boxes, accessories Material thickness: 4 mm

Fitting frame size 2 Properties: - For installation of service units or blank covers, as a base for pedestal boxes or as a blank cover - Dimensions: 290 x 290 mm Designation

UDM2200Q06

Fitting frame for underfloor box size 2 blank Fitting frame for underfloor box size 2 with blankings GBZ Fitting frame for underfloor box size 2 with blankings E04 Fitting frame for underfloor box size 2 with blankings E09 Fitting frame for underfloor box size 2 with blankings Q06 Fitting frame for underfloor box size 2 with blankings R06 Fitting frame for underfloor box size 2 with blankings Q12

Ø [mm] a [mm] b [mm] PU

Order no.

5 10 10 10 10 10 10

UDM2000BLD UDM2050GBZ UDM2147E04 UDM2200E09 UDM2200Q06 UDM2215R06 UDM2244Q12

50 147 200 200

247 253 200

244

244

215

Fitting frame size 3 Properties: - For installation of service units or blank covers, as a base for pedestal boxes or as a blank cover - Dimensions: 360 x 360 mm

Designation

UDM3215R06

Fitting frame for underfloor box size 3 blank Fitting frame for underfloor box size 3 with blankings GBZ Fitting frame for underfloor box size 3 with blankings E04 Fitting frame for underfloor box size 3 with blankings E09 Fitting frame for underfloor box size 3 with blankings Q06 Fitting frame for underfloor box size 3 with blankings R06 Fitting frame for underfloor box size 3 with blankings Q12 Fitting frame for underfloor box size 3 with blankings R10 Fitting frame for underfloor box size 3 with blankings Q08 Fitting frame for underfloor box size 3 with blankings R12

Ø [mm] a [mm] b [mm] PU

Order no.

5 10 10 10 10 10 10 10 10 10

UDM3000BLD UDM3050GBZ UDM3147E04 UDM3200E09 UDM3200Q06 UDM3215R06 UDM3244Q12 UDM3275R10 UDM3294Q08 UDM3306R12

50 147 200 200

247 253 200

244

244

294

294

215 275 306

Heavy-duty fitting frame size 3 Properties: - For installation of service units or blank covers, as a base for pedestal boxes or as a blank cover - Height-adjustment set screws need to be ordered separately - Dimensions: 360 x 360 mm

Designation

UDM3215SLR06

Ø [mm] a [mm] b [mm] PU

Heavy-duty fitting frame with blankings Q06 Heavy-duty fitting frame with blankings Q12 Heavy-duty fitting frame with blankings R06 Heavy-duty fitting frame with blankings R12

Technical changes reserved

200 244 215 306

200 244

1 1 1 1

Order no.

UDM3200SLQ06 UDM3244SLQ12 UDM3215SLR06 UDM3306SLR12

19

electraplan.UK

electraplan.UK Universal junction boxes, accessories Levelling frame Properties: - Levelling frame made of aluminium for fitting frame UDM - For adjustment to screed layers with a height of more than 35 mm

Designation

UDAR335

Levelling frame size 2 height 35 mm Levelling frame size 3 height 35 mm

Outer dimension A [mm]

Internal dimension I [mm]

PU

Order no.

296 x 296 290 x 290 1

UDAR235

366 x 366 360 x 360 1

UDAR335

Pipe inlet for universal junction box with bottom plate and sheet metal casing

UDS32050RE

Properties: - Pipe inlet made of plastic, for connection of electrical installation pipes to underfloor box UDS3070120 - With pre-stamped sealing plugs for pipe diameters 20, 32, 40 and 50 mm Material: Polyamide Designation

PU

Pipe inlet for underfloor box UDS3070120

260

Order no.

UDS32050RE

Heavy-duty frame Properties: - Heavy-duty frames are supplied as a set (with height-adjustment set screws) - Suitable for use with universal junction boxes UDB, UDH, UDS size 3 - Heavy-duty frames can be subjected to loads of up to 20 kN in conjunction with heavy-duty fitting frames Designation

UDSLS098

20

Height adjustment range [mm]

Heavy-duty frame for screed height 073-098 Heavy-duty frame for screed height 093-118 Heavy-duty frame for screed height 113-138 Heavy-duty frame for screed height 138-163 Heavy-duty frame for screed height 158-183 Heavy-duty frame for screed height 178-203 Heavy-duty frame for screed height 198-223

Technical changes reserved

PU

4 4 4 4 4 4 4

Order no.

UDSLS098 UDSLS118 UDSLS138 UDSLS163 UDSLS183 UDSLS203 UDSLS223

Material Junction box: Galvanised steel sheet Main body: Plastic, PP Formwork element: Styropor

Shapes E04: cornered 147 x 247 mm E09: cornered 200 x 253 mm R06: round 215 mm R2: round 242 mm R10: round 275 mm R12: round 306 mm Q06: square 200 x 200 mm Q12: square 244 x 244 mm Q08: square 294 x 294 mm

Note - orientate formwork elements before casting the screed - remove the formwork element after the screed is set

Junction box with steel sheet formwork for formwork elements Properties: - 500 x 500 mm - including base support SEBD500GT

Designation

PU

Formwork element floor socket base support

1

Order no.

SEBD500GT

Formwork element base support Properties: - 350 x 350 mm - For use with e.g. cavity floors Designation

PU

Formwork element base support 350x350 mm

1

Order no.

SEGT350

SEGT350

Formwork elements for service units and height adjustable cassettes Properties: - height 200 mm - in 5 segments with 40 mm height, divisible, can thus be matched with floor construction height

SEVR06200

Designation

PU

Formwork element VE04 147x247mm H=200mm Formwork element VE09 200x253mm H=200mm Formwork element VR06 rund 215mm H=200mm Formwork element VR2 rund 242mm H=200mm Formwork element VR10 rund 275mm H=200mm Formwork element VR12 rund 306mm H=200mm Formwork element VQ06 200x200mm H=200mm Formwork element VQ12 244x244mm H=200mm Formwork element VQ08 294x294mm H=200mm

1 1 1 1 1 1 1 1 1

Technical changes reserved

Order no.

SEVE04200 SEVE09200 SEVR06200 SEVR2200 SEVR10200 SEVR12200 SEVQ06200 SEVQ12200 SEVQ08200

21

electraplan.UK

Formwork elements for service units and height adjustable cassettes

electraplan.UK

electraplan.UK Order number system Underfloor trunking Identifier

Type

Trunking width

Trunking height

Number of compartments

UK = underfloor trunking

W

X

Y

Z

= basic profile E = end bracket B = bracket K = vertical elbow S = Clamp M = expansion bushing

190 = 190 mm 240 = 240 mm 340 = 340 mm

28 = 28 mm 38 = 38 mm 48 = 48 mm

0 = no compartments 2 = two compartments 3 = three compartments

Universal junction box Identifier

Variant

Size

Height adjustment range

UD = underfloor junction box

X

Y

Z

B = with bottom plate 2 = 428 x 428 mm H = with retaining tabs 3 = 498 x 498 mm S = with sheet metal casing

050080 = 50 - 80 mm 075125 = 75 - 125 mm 120170 = 120 - 170 mm 165215 = 165 - 215 mm 215265 = 215 - 265 mm For version S only: 070120 = 70 - 120 mm

Fitting frame Identifier

Variant

Size

Size and type of blankings

UD = underfloor junction box

X

Y

M = fitting frame

2 = 290 x 290 mm 3 = 360 x 360 mm

000BLD = no blanking 050GBZ = blanking GBZ round 50 mm 215R06 = blanking R06 round 215 mm 275R10 = blanking R10 round 275 mm 306R12 = blanking R12 round 306 mm 200Q06 = blanking Q06 200 x 200 mm 294Q08 = blanking Q08 294 x 294 mm 244Q12 = blanking Q12 244 x 244 mm 147E04 = blanking E04 147 x 247 mm 200E09 = blanking E09 200 x 253 mm

Variant

Size

Elevation/pre-stamping

W

X

Y

Z

Levelling frame and pipe inlet Identifier UD = underfloor junction box

2 = 428 x 428 mm AR = levelling frame S = with sheet metal casing 3 = 498 x 498 mm 2050 = pre-stamping 20 - 32 - 40 - 50 mm

35 = 35 mm

Type

RE = pipe insert

Heavy-duty frame and fitting frame for heavy loads Identifier

Variant

Screed height range

UD = underfloor junction box

Y

Z

SLS = heavy-duty frame

098 = 073 - 098 mm 118 = 093 - 118 mm 138 = 113 - 138 mm 163 = 138 - 163 mm 183 = 158 - 183 mm 203 = 178 - 203 mm 223 = 198 - 223 mm

Identifier

Variant

Size of blanking

Type

Type of blanking

UD = underfloor junction box

W

X

Y

Z

M3 = fitting frame size 3

200 = 200 x 200 mm 244 = 244 x 240 mm 215 = round 215 mm 306 = round 306 mm

SL = heavy-duty

Q06 = blanking Q06 200 x 200 mm Q12 = blanking Q12 244 x 244 mm R06 = blanking R06 round 215 mm R12 = blanking R12 round 306 mm

22

Technical changes reserved

electraplan.UK

electraplan.UK Screed-covered trunking systems

Vertical elbow UKK240383 Clamp UKS240380

Universal junction box UDH3120170 Underfloor trunking UK190382

Underfloor trunking UK340483 Bracket UKB340480

Universal junction box UDS3070120 Pipe inlet UDS32050RE Fitting frame UDM3306R12

Junction box, square UDAQ125A End bracket UKE340480

Technical changes reserved

23

electraplan.UK

electraplan.UK Advantages at a glance Quick and easy installation The pre-fabricated underfloor trunking system with accessories enables quick and easy installation on-site. Robust quality All underfloor trunking and junction boxes are made of galvanised sheet metal in accordance with DIN EN 10327 and are therefore protected against corrosion. Easy cable routing and installation The covers of the underfloor trunking are snapped on and can be taken off before the screed is poured. Cables can be placed in the open trunking from above. This means that there is no need for the complicated process of pulling the wiring into the trunking. This facilitates a convenient, space-saving, orderly and bundled installation of cables.

Service unit VR12059005 Device casings GBVR400

Universal junction box UDS3070120

Fitting frame UDM3244Q12

24

Technical changes reserved

electraplan.UK Technical changes reserved

25

electraplan.UK

electraplan.UK Selection of a number of possible combinations

ESR1339010

ESR2339010

ESR3339010

GTVR400

GBVTB48

GBMBV34R1

GBMBV23T1

GBMBV34R2

GBMBV23T2

GTMBV04T2

GBMBV34R3

GBMBV03T3

GTMBV04T3

EDSRJ45C6A

GBVTB

GTVDM022

GBVDM301

GTVDM082

GBVDM311

GTVDM013

GBVDM224

GTMBV34T1

GBVR400 GTVR400

GTVD300

VQ12057011

VR12057011

VR10057011

UDM3244Q12

UDM3306R12

UDM3275R10

UDH3120170

UDS3070120

GBVR400

UDM2244Q12

UDB3120170

26

Technical changes reserved

electraplan.UK ESR1339010

ESR2339010

EDSRJ45C6A

GBVTB48

GBVTB

ESR3339010

GBMBV34R1

GBMBV34R2

GBMBV34R3

GBVDM301

GBMBV23T1

GTMBV34T1

GTVDM082

GBVDM311

GBMBV23T2

GTMBV30T2

GTVDM013

GBVDM224

GBVR300 GTVR300

GTVR300 GBVR300

GTVDM022

GTVD200

VE090057011

VQ06057011

VR06057011

UDM3200E09

UDM3200Q06

UDM3215R06

UDM2200E09

UDM2200Q06

UDM2215R06

UDB2120170

Technical changes reserved

UDH2120170

27

electraplan.UK

electraplan.UK Line volume Determining the line volume The line volume must be known in order to define the correct trunking size. In practice, lines never run perfectly in parallel and side-by-side in a way that would ensure maximum space utilisation. This is why the formula (d)², i.e. the diameter squared, must be applied. To ensure sufficient space for possible later retrofitting, trunking ducts should only be filled to 50% of their volume. This also makes it easier to pull the lines into the trunking. Also, it must be noted that the calculation does not take into account bottom troughs and outlets that possibly interrupt the line path. In practice, energy and data lines are routed separately from each other in the trunking. Partition walls separate the trunking into several compartments. If this applies to your installation, then calculate the volume required for each compartment separately. The line volume configurator provided at www.hager.de will help you make the necessary calculations. The values calculated are for guide purposes only. Heat dissipation caused by lines carrying high currents must be taken into account. Compliance with all applicable regulations such as DIN VDE 0100 must be ensured.

safety

Compart- Nominal ment width height of trunking mm mm 60 28

70

75

85

100

110

115

140

200

28

38 48 28 38 48 28 38 48 28 38 48 28 38 48 28 38 48 28 38 48 28 38 48 28 38 48

factor

Usable cross-section 5 cm² 16.8 33

23

17

13

10

8

6

5

4

4

3

3

2

2

2

2

22.8 28.8 19.6 26.6 33.6 21.0 28.5 36.0 23.8 32.3 40.8 28.0 38.0 48.0 30.8 41.8 52.8 32.2 43.7 55.2 39.2 53.2 67.2 56.0 76.0 96.0

31 40 27 36 46 29 39 50 33 44 56 38 52 66 42 58 73 44 60 76 54 73 93 77 105 133

23 29 20 27 34 21 29 36 24 32 41 28 38 48 31 42 53 32 44 56 40 54 68 57 77 97

17 22 15 20 26 16 22 28 18 25 31 21 29 37 24 32 41 25 34 43 30 41 52 43 59 75

14 17 12 16 20 12 17 22 14 19 25 17 23 29 19 25 32 19 26 34 24 32 41 34 46 59

11 14 9 13 16 10 14 18 11 16 20 14 19 24 15 20 26 16 21 27 19 26 33 28 38 48

9 11 8 10 13 8 11 14 9 13 16 11 15 19 12 17 21 13 18 22 16 21 27 23 31 39

7 10 6 9 11 7 9 12 8 11 14 9 13 16 10 14 18 11 15 19 13 18 23 19 26 33

6 8 5 7 9 6 8 10 7 9 12 8 11 14 9 12 15 9 12 16 11 15 19 16 22 28

5 7 5 6 8 5 7 9 6 8 10 7 9 12 7 10 13 8 11 14 10 13 17 14 19 24

5 6 4 5 7 4 6 8 5 7 9 6 8 10 6 9 11 7 9 12 8 11 14 12 16 21

4 5 3 5 6 4 5 7 4 6 7 5 7 9 6 8 10 6 8 10 7 10 13 10 14 18

3 4 3 4 5 3 4 6 4 5 7 4 6 8 5 7 9 5 7 9 6 9 11 9 13 16

3 4 3 4 5 3 4 5 3 4 6 4 5 7 4 6 8 4 6 8 6 8 10 8 11 14

3 3 2 3 4 2 3 4 3 4 5 3 5 6 4 5 7 4 6 7 5 7 9 7 10 13

2 3 2 3 4 2 3 4 2 4 5 3 4 6 3 5 6 4 5 6 4 6 8 7 9 12

45 57 39 53 67 42 57 72 47 64 81 56 76 96 61 83 105 64 87 110 78 106 134 112 152 192

Line diameter in mm 6

7

8

9

10

11

12

Technical changes reserved

13

14

15

16

17

18

19

20

electraplan.UK

electraplan.UK Function and application Application The screed-embedded underfloor trunking system can be used with any kind of screed such as cement screed, floating screed, flowing screed, or, if special provisions are made, hot screed/mastic asphalt. The screed-embedded trunking system is suitable for use in office, administration or exhibition areas, but also in residential buildings. Anywhere, in fact, where sturdy construction is valued. How it works Our probably most widely used underfloor trunking system is very simple yet surprisingly diverse when it comes to potential applications. Junction boxes are connected to each other via underfloor trunkings to form networks. They ensure a structured supply and offer access to energy, data and telecommunication lines through the floor. Users can customise their installation to suit individual requirements thanks to the large range of different trunking cross-sections that is available. Afterwards the screed is installed up to the upper edge of the junction boxes. Depending on the properties of the floor surface (usually a bare concrete floor), junction boxes with pre-stamped trunking inlets made completely of sheet metal or junction boxes with foil casing and factory-fitted footfall sound insulation can be used. With both junction box variants, stepless height adjustment can be performed via the height adjustment screws that are accessible from above. The underfloor trunking is completely concealed once the screed has been poured. Then you can install service units or cassettes in the junction boxes, including sockets and data systems.

Technical changes reserved

29

electraplan.UK

electraplan.UK Technical data Bracket UKB Bracket UKB for fastening the trunking onto the bare floor. One bracket is required for each trunking inlet in junction boxes. Any additional requirements due to local conditions should be calculated and ordered separately. Material: Galvanised sheet metal, Galvanised in accordance with

DIN EN 10327 Material thickness: 0.90 mm

Order number

Dimensions b x a [mm]

UKB190280

190 x 28

UKB190380 UKB190480 UKB240280 UKB240380 UKB240480 UKB340280 UKB340380 UKB340480

190 x 38 190 x 48 240 x 28 240 x 38 240 x 48 340 x 28 340 x 38 340 x 48

Installation example

Clamp UKS Clamp UKS for connection of trunking sections at the butt joints and for fastening the trunking. Equi­ potential bonding is achieved by clamping in the ends of the trunking or the ends of the vertical elbow between the cover and lower part. We recommend an allowance of 0.5 clamps per metre of trunking. Any additional requirements due to local conditions should be calculated and ordered separately. Material: Galvanised sheet metal, Galvanised in accordance with

30

DIN EN 10327 Material thickness: 0.90 mm

Order number

Dimensions b x a [mm]

UKS190280

190 x 28

UKS190380 UKS190480 UKS240280 UKS240380 UKS240480 UKS340280 UKS340380 UKS340480

190 x 38 190 x 48 240 x 28 240 x 38 240 x 48 340 x 28 340 x 38 340 x 48

Technical changes reserved

electraplan.UK

electraplan.UK Technical data Vertical elbow UKK Vertical elbow UKK for routing transitions from horizontal to the vertical plane. The connection between the vertical elbow and the trunking is made with a clamp. Material: Galvanised sheet metal, Galvanised in accordance with Order number

DIN EN 10327 Material thickness: 0.75 mm

Variant

Dimensions b x a [mm]

UKK190282

2 compartments

190 x 28

Dimensions of compartments 75 / 115

UKK190382 UKK190482 UKK190283 UKK190383 UKK190483 UKK240282 UKK240382 UKK240482 UKK240283 UKK240383 UKK240483 UKK340282 UKK340382 UKK340482 UKK340283 UKK340383 UKK340483

2 compartments 2 compartments 3 compartments 3 compartments 3 compartments 2 compartments 2 compartments 2 compartments 3 compartments 3 compartments 3 compartments 2 compartments 2 compartments 2 compartments 3 compartments 3 compartments 3 compartments

190 x 38 190 x 48 190 x 28 190 x 38 190 x 48 240 x 28 240 x 38 240 x 48 240 x 28 240 x 38 240 x 48 340 x 28 340 x 38 340 x 48 340 x 28 340 x 38 340 x 48

75 / 115 75 / 115 60 / 70 / 60 60 / 70 / 60 60 / 70 / 60 100 / 140 100 / 140 100 / 140 85 / 70 / 85 85 / 70 / 85 85 / 70 / 85 140 / 200 140 / 200 140 / 200 115 / 110 / 115 115 / 110 / 115 115 / 110 / 115

Installation example

End bracket UKE End bracket for screed-embedded closed underfloor trunking. Material: Galvanised sheet metal, Galvanised in accordance with

DIN EN 10327 Material thickness: 0.90 mm

Order number

Dimensions b x a [mm]

UKE190280

190 x 28

UKE190380 UKE190480 UKE240280 UKE240380 UKE240480 UKE340280 UKE340380 UKE340480

190 x 38 190 x 48 240 x 28 240 x 38 240 x 48 340 x 28 340 x 38 340 x 48

Technical changes reserved

31

electraplan.UK

electraplan.UK Installation instructions, Screed-embedded trunking system General instructions: DIN standard Please observe for screed overlap of trunkings according DIN 18560 “Screeds of building industry”. Earthing System components must be included in the earthing measures according to DIN VDE 0100. Support Components must be supported to prevent deformation, if required. Sealing Trunking and universal junction boxes must be protected against screed ingress during installation. Curing Do not walk or impose any mechanical load on the trunking system before the screed has hardened. Protective covers The protection lids may only be removed from the universal junction box and be replaced by the fitting frames immediately before installation of the flooring. Conterminal trades Observe the general information and the information concerning conterminal trades (screed layer, floor fitter).

32

Technical changes reserved

electraplan.UK

electraplan.UK Installation instructions Installation in monolithic screed

Installation in floating floor screed

Installation in floating screed

Disperse the cement screed directly onto the concrete slab and onto the underfloor trunkings.

Cement screed is applied onto an insulating layer. The underfloor trunking is integrated in this insulation layer.

The installation of trunking and universal junction boxes is similar to the installation in cement screed. In addition, the system must be protected against the ingress of floating screed during installation.

Installation in hot screed (UDS3 only)

Position the universal junction boxes according to the lay-out.

Notch universal junction boxes UDS3

When casting hot screed or mastic asphalt temperatures of approx. 280 °C may occur. This requires trunking and universal junction boxes to be covered and insulated with bituminous corrugated board. Due to the high temperatures, lines must not be installed before the hot screed has completely cooled down.

Position the universal junction boxes on the slab and secure them according to the layout.

Create a notch in the corresponding sidewall of the universal junction box to connect the trunking. Use a wire cutter to cut out the panel along the perforation as required.

Connect the trunking to universal junction boxes UDS3

Connect the trunking to universal junction box UDH

Bevel joints are possible

Insert the trunking through the notched side part and move it up to the stop at the bottom plate. The system must be protected by the customer against the ingress of liquid screed during installation.

Insert the trunking under the flexible screed casing. Cut the flexible screed casing so that the trunking is enclosed with the foil. The system must be protected by the customer against the ingress of liquid screed during installation.

Universal junction boxes UDB3 and UDH3 allow trunking to be introduced at an angle as specified. This layout makes the drawing of cables more difficult. Up to 50° for junction box UDH2 and UK190 or up to 40° for UDH2 and UK240.

Technical changes reserved

33

electraplan.UK

electraplan.UK Installation instructions Lay the trunking

Cut the trunking as required

Attach the clamps

Lay the trunking segments edge to edge. The partition walls must be aligned.

Cut trunking segments to length, if required. Sharp edges must then be deburred.

Connect the two trunking segments at their edges using a clamp and dowel it to the slap through the two holes (7 x 15 mm). The installation of the clamp is also required to ensure equipotential bonding between the trunking segments in accordance with DIN VDE 0100.

Additional brackets

Connect the vertical elbow

Connect the feed channel

If required, trunking segments can be secured between the joints using additional brackets.

Connect the vertical elbows as wall connection to the trunking using a clamp.

A feed channel can be attached to the vertical elbow for further line routing. This trunking segment connects the underfloor trunking to the wall trunking.

Attach the end bracket

Earthing measures

If the trunking ends in the middle of the room, then the cut edge must be closed by an end bracket. The end cap does not need to be secured by screws.

The trunking segments are joined mechanically and electrically by the clamps. All contact areas must be clean and free of grease.

34

Technical changes reserved

electraplan.UK

electraplan.UK Installation instructions Alternative installation method: Attach the universal junction box

Remove the upper part of the box

Secure the universal junction box to the slab.

Pull the upper part from the universal junction box out of the soundproofing mounts. Bottom plate and soundproofing mounts remain firmly on the slab.

Attach the upper part of the trunking

Insert the cables from above

Thanks to the removable lid, the trunking can attached to the slab quickly and easily. Drive anchors, fasteners or other means may be used for the purpose.

Cables can be placed in the open trunking from above. It is not necessary to pull the cables in. This facilitates a convenient, space-saving, orderly and bundled installation of cables. Caution: Due to the high temperatures, this is not feasible in hot screed installations.

Attach the lid

Attach the upper part of the box

The lid of the trunking is put on from above and snaps into place.

The upper part of universal junction box UDH and UDB is put on from above and over the trunking into the soundproofing mounts.

Technical changes reserved

35

electraplan.UK

electraplan.UK Installation instructions, universal junction boxes General instructions: DIN standard Please observe for screed overlap of trunkings according DIN 18560 "Screeds of building industry". Earthing System components must be included in the earthing measures according to DIN VDE 0100. Sealing Trunking and universal junction box must be protected by the customer against screed ingress during installation. Hardening Do not walk on the trunking system or impose any mechanical loads on it before the screed has hardened. Protective covers The protection lids may only be removed from the universal junction box and be replaced by the fitting frames immediately before installation of the flooring. Conterminal trades Observe the general information and the information concerning conterminal trades (screed layer, floor fitter).

36

Technical changes reserved

electraplan.UK

electraplan.UK Installation instructions, universal junction boxes Installation in monolithic screed

Installation in floating floor screed

Installation in floating screed

Cement screed is directly applied onto the slab and the galvanised underfloor trunking.

Cement screed is applied onto an insulating layer. The underfloor trunking is integrated in this insulation layer.

The installation of trunking and universal junction boxes is similar to the installation in cement screed. In addition, the system must be protected against the ingress of floating screed during installation.

Installation in hot screed (UDS3 only)

Position the universal junction boxes according to the lay-out.

Check the levelling area

When casting hot screed or mastic asphalt temperatures of approx. 280 °C may occur. This requires trunking and universal junction boxes to be covered and insulated with bituminous corrugated board. Due to the high temperatures, lines must not be installed before the hot screed has completely cooled down.

Locate the universal junction boxes on the slab and secure them according to the layout. The flexible screed casing must be on the outside.

Check the levelling area on the slab. The studs of universal junction box UDB or UDH can be replaced, if required. Turn them counterclockwise to separate them from the soundproofing mounts. Do not pull the studs out or drive them in.

Screed height above 120 mm with UDS3

Attach universal junction box UDH

Attach junction box UDB or UDS3

For screed heights of more than 120 mm the height of universal junction box UDS3 can be increased by 35 mm using levelling frame UDAR335. Place levelling frame onto the frame of the underfloor box and secure it with four screws.

If universal junction box UDH is used, dowel all four brackets to the slab. Each bracket is pre-drilled with 1 x 6 mm and 1 x 7 mm holes.

For universal junction box UDB or UDS3, the bottom plate must be secured to the slab at all four corners. Holes of 6.5 mm are provided in each corner.

Technical changes reserved

37

electraplan.UK

electraplan.UK Installation instructions, universal junction boxes Level the universal junction box

Feed in the trunking

Angled trunking in-feed is possible

Level the box frame to the required height using a screwdriver to turn the studs at all four corners. The elastic mounting of the frame prevents cracks in the screed during curing.

Cut in the film formwork to fit height and width of the trunking. Lift the film tab and push the trunking up to the stop on the bottom plate or approx. 40 mm under the universal junction box.

Universal junction boxes UDB3 and UDH3 allow trunking to be introduced at an angle as specified. This layout makes the installation of lines more difficult.

Attach the trunking

Connect the film

Cut out universal junction box UDS3

Pinch the film tab between trunking and bracket. Attach the bracket using plugs and screws.

Join the screed formwork film at all four corners using a stapling pliers.

Before installation, a corresponding cut-out must be created in the universal junction box to allow connection of the trunking. Use a wire cutter to cut out the panel along the perforation as required.

Feed in the trunking

Attach the trunking

Grounding of UDS3 / UDB

Introduce the trunking into the opening created in the sidewall and push it against the stop at the bottom plate.

Connect the trunking to the universal junction box using a bracket.

The force of the bracket pressing the trunking onto the bottom plate ensure the electric conductivity of the universal junction box and the trunking. The contact areas must be clean and free of grease. The ground conductor in the universal junction box must be connected to the ground connection on site.

38

Technical changes reserved

electraplan.UK

electraplan.UK Installation instructions, universal junction boxes Grounding underfloor box UDH

Install the screed

Replace the protection lid

Connect the ground cable provided in the universal junction box the supplying trunking end to ensure electrical conductivity between the two components. The ground cable in the universal junction box must be connected to the ground connection on site.

Install screed up to the top edge of the universal junction boxes. The protection lid only serves as protection against ingress of foreign material and must not be rolled over or subject to any other load.

Do not remove the protection lid until the flooring is being installed, and replace it by an fitting frame. Secure it to the box frame or levelling frame using screws.

Install the service unit

After laying the flooring, cut out the openings of the installed fitting frames and install the service unit or cassette.

Technical changes reserved

39

electraplan.UK

electraplan.UK Installation instructions, Pipe inlet UDS32050RE General instructions: Several diameters By breaking out the perforated plugs, conduits with standard diameters of 20 mm, 32 mm, 40 mm and 50 mm can be used. No additional parts needed No additional parts such as reduction pieces or adapters are needed. Full-length support The out-of-centre arrangement of the plugs ensure that the ducts remain flat on the slab along their entire length. This ensure a continuous thickness of the screed right up to the sidewalls of the junction box. Snap-in function The conduits snap in to facilitate the specific use of underfloor trunking or conduits.

40

Technical changes reserved

electraplan.UK

electraplan.UK Installation instructions, Pipe inlet UDS32050RE Cut out the sidewall

Remove the sidewall

Snap in the pipe inlet

Notch the sidewall along the outermost perforation using a wire cutter.

Remove cut-out sheet metal from sidewall.

From the front face, snap pipe inlet UDS3 RE 20-50 into the lugs provided. The connection does not require any screws.

Notch the pipe inlet

Insert cable conduit

Position cable conduit

Notch the perforated plugs to the required diameter using a wire cutter or utility cutter.

Insert the cable conduit into the opening.

Let the cable conduit protrude approximately 1-2 cm into the inside of the junction box. Then attach the cable conduit outside the junction box to the slab to prevent it from floating.

Technical changes reserved

41

electraplan.UK

electraplan.UK operating principle, formwork elements 1: SEBD500GT - Junction box incl. base support

2: Preparing the base support

Junction box 500 mm x 500 mm with steel sheet formwork for formwork elements incl. base support, available as a set.

Prepare the base support for installation by simply pushing the parts together.

3: Attaching the junction box to the base support

4: Positioning the junction box

Attachment is performed by simply bending the pre-formed metal tabs.

Place the junction box incl. base support on the trunking system and remove the page walls along the matching perforations. Orientate and fasten on the bare concrete floor.

42

Technical changes reserved

electraplan.UK

electraplan.UK operating principle, formwork elements 5: Running and fixing lines

6: Fitting formwork elements

Run the lines through the junction box and fix to the base support using cable ties.

Place the Styropor formwork elements on the base support. The formwork element consists of 5 parts each with a height of 40 mm, thus it is possible to match individual floor construction heights.

7: Applying screed

8: Removing the base support and formwork element

After sealing the system in situ (e.g. using adhesive textile tape) apply the screed.

After the screen has dried, remove the base support and formwork element and install the service unit and/or height adjustable stainless steel cassette.

Technical changes reserved

43

electraplan.UK

electraplan.UK operating principle, formwork elements

6LE000527A 6LE000527A

DE FR DE GB FR NL GB DK NL FI DK NO FI SE NO IT SE ES IT PT ES CZ PT BA CZ UK BA UK

Montageanleitung Notice d'instructions Montageanleitung Mounting instructions Notice d'instructions Montage instructie Mounting instructions Monteringsvejledning Montage instructie Asennusohje Monteringsvejledning Montasjeanvisning Asennusohje Monterings instruktioner Montasjeanvisning Istruzioni di instruktioner montaggio Monterings Instrucciones de montaje Istruzioni di montaggio Instruções de de montagem Instrucciones montaje Montážní návod Instruções de montagem Uputstvo montažu Montážní za návod Iнструкції з установки Uputstvo za montažu Iнструкції з установки

HR HU HR LT HU LV LT PL LV RO PL SK RO RU SK BG RU GR BG SI GR EE SI IS EE AR IS AR

Upute za montažu Szerelési útmutató Upute za montažu Montavimoútmutató instrukcija Szerelési Montāžas instrukcija Montavimo instrukcija Instrukcja montażowa Montāžas instrukcija Intructiuni montażowa de montare Instrukcja Návod na montáž Intructiuni de montare Указания по установке Návod na montáž Инструкции монтаж Указания поза установке Инструкции за монтаж Navodilo za montažo Paigaldusjuhised Navodilo za montažo Leiðbeiningar Paigaldusjuhised Leiðbeiningar

1x 1x 1x

1x

1x

1x

4x 4x

1x 1x

1

6LE000527A

1

6LE000527A

44

Technical changes reserved

electraplan.UK

electraplan.UK operating principle, formwork elements

6LE000527A

2 Technical changes reserved

45

Hager 08.2015

electraplan.UK

electraplan.UK operating principle, formwork elements

3

46

www.hagergroup.net

Technical changes reserved

6LE000527A

electraplan.UK Technical changes reserved

47

tehalit.BKB electraplan.BK

Screed-flush trunking systems

tehalit.BKB | electraplan.BK tehalit.BKB: Perfectly integrated With the screed-flush trunking system tehalit.BKB, energy, data and communication connections can be flexibly provided anywhere they are needed – even in rooms with glass walls or large window surface. The system could not be simpler: Thanks to the range of specially shaped elements in the tehalit. BKB system, concealed lines can be routed to any corner of the room. electraplan.BK: Flat & wide Thanks to the very compact height of the electraplan.BK system, it is also suitable for very shallow screed depths from 30 mm without and from 45 mm with footfall sound insulation. With a large trunking width of up to 600 mm, the system offers plenty of space to house large volumes of cables and lines. Particularly practical: Even after installation, the trunking covers can be opened at any time, and thanks to the flexible foil casing it is no problem at all to cross over e.g. heating pipes. Particularly practical: Even after installation, the trunking covers can be opened at any time, and thanks to the flexible foil casing it is no problem at all to cross over e.g. heating pipes. Alternatively we also have trunking with separate bottoms that ensure a clean and tidy installation, protecting lines against dust and dirt.

System overview Balustrade floor trunking

Partition walls and accessories

77

Accessories

79

Technical Information (BKB)

83

50 51

electraplan.BK System overview with flexible formwork staples

56

Order number system

88

System overview with trunking bottom

57

Technical information (BK)

90

Trunking overview

58

Screed-flush trunking system with flexible screed casing for dry-cleaned floors

62

Screed-flush trunking system with trunking bottom for dry-cleaned floors

64

Covers for screed-flush trunking systems for dry-cleaned floors

66

Cross members for screed-flush trunking systems for dry-cleaned floors

68

Screed-flush trunking system with flexible screed casing and sealing option

70

Screed-flush trunking system with trunking bottom and sealing option

72

Covers for screed-flush trunking systems with sealing option

74

Cross members for screed-flush trunking systems with sealing option

75

Junction boxes and accessories

76

49

tehalit.BKB electraplan.BK

tehalit.BKB

tehalit.BKB System overview

7

tehalit.BKB

9

9 5

ß

4

2 0

1

3 “ 6

5

8

tehalit.BKB 1 Trunking lower part 2 Upper part with brush 3 Upper part with brush for LED 4  Upper part closed 5 Low-angled bracket for bottom part 6 Low-angled bracket, outer, for upper part with brush 7 Low-angled bracket for upper part closed 8 End plate 9 Coupling set 0 Device carrier for trunking sockets ß Device carrier for data systems technology “ Set screws

50

Technical changes reserved

tehalit.BKB Balustrade floor trunking - Withstands point loads of up to 150 kg - Minimum recommendation: 4 set screws and 4 fastening screws per running metre (not included in the delivery package) - Straightforward retrofitting for energy and data - Important: Installation of edge insulation strips between trunking and screed - Observe the earthing requirements

Available brush colours Black Material Galvanised sheet metal Standard length 2000 mm Lower part 2000 mm Upper part 2 x 1000 mm

tehalit.BKB

- Screed-flush trunking for drycleaned floors in accordance with DIN EN 50085 - Installation of devices with device carriers - Ease of access thanks to removable upper part and cable outlet on the wall side (outlet brush) - Minimum screed height 96 mm - Upper part can be covered with all types of floor coverings (parquet flooring, carpets, tiles or laminate) (5 - 25 mm) - Levelling of the trunking via internally accessible set screws

Form of delivery Trunking comprising upper and lower part

BKB trunking lower part Dimensions (W x H): 250 x 85 mm Length: 2000 mm Including assembly cover and 6 drilling screws for fastening Set screws not included in delivery package

BKB250851

Designation

PU

Lower part of balustrade floor trunking BKB25085

2

Order no.

BKB250851

BKB upper part with brush Supplied length: 2 x 1000 mm Available brush colours: Black Designation

PU

Upper part with brush for BKB25085

2

Order no.

BKB250852B

BKB250852B BKB upper part with brush for LED Supplied length: 2 x 1000 mm Available brush colours: Black Transparent range for LED chain installation Designation

PU

Upper part with brush and LED for BKB25085

2

Order no.

BKB250852BLED

BKB250852BLED BKB upper part closed Supplied length: 2 x 1000 mm For installation away from the wall Designation

PU

Upper part closed for BKB25085

2

Order no.

BKB250852G

BKB250852G

Technical changes reserved

51

tehalit.BKB Balustrade floor trunking BKB low-angled bracket for bottom part

tehalit.BKB

Lower part for low-angled bracket, inner and outer Dimensions (W x H) 250 x 85 mm Including assembly cover and 7 drilling screws for fastening Set screws not included in delivery package BKB2508551

Designation

PU

Low-angled bracket for lower part, inner/outer for BKB25085

1

Order no.

BKB2508551

BKB low-angled bracket, inner, for upper part with brush Available brush colours: Black Designation

PU

Low-angled bracket, upper part, brush/inner for BKB25085

1

Order no.

BKB2508554B

BKB2508554B BKB low-angled bracket, inner, for upper part with brush and LED Available brush colours: Black Transparent range for LED chain installation

BKB2508554BLED

Designation

PU

Low-angled bracket, upper part, brush/LED/inner for BKB25085

1

Order no.

BKB2508554BLED

BKB low-angled bracket, outer, for upper part with brush Available brush colours: Black Designation

PU

Low-angled bracket, upper part, brush/outer for BKB25085

1

Order no.

BKB2508553B

BKB2508553B BKB low-angled bracket, outer, for upper part with brush and LED Available brush colours: Black Transparent range for LED chain installation Designation

PU

Low-angled bracket, upper part, brush/LED/outer for BKB25085

1

Order no.

BKB2508553BLED

BKB2508553BLED BKB low-angled bracket, upper part closed Upper part for low-angled bracket, inner and outer For installation away from the wall Designation

PU

Low-angled bracket, upper part closed, for BKB25085

1

BKB2508554G

52

Technical changes reserved

Order no.

BKB2508554G

tehalit.BKB Balustrade floor trunking BKB T-piece adapter, galvanised sheet metal Includes 2 countersunk screws and 6 drilling screws PU

T-piece adapter for BKB25085 galv. sh. metal

1

Order no.

BKB250858T

BKB250858T BKB end plate, galvanised sheet metal Includes 2 countersunk screws Designation

PU

End plate for BKB250856 galv. sh. metal

1

Order no.

BKB250856

BKB250856 BKB coupling set, galvanised sheet metal Connector, electrical and mechanical for BKB25085 lower parts Includes 4 countersunk screws Designation

PU

Coupling set for BKB250857 galv. sh. metal

1

Order no.

BKB250857

BKB250857 BKB device carrier for trunking sockets (C-profile), galvanised sheet metal Device carrier for fastening of trunking sockets (C-profile device installation) Designation

PU

Device carrier for trunking socket for BKB

1

Order no.

BKBGTR910

BKBGTR910 BKB device carrier for DNT devices, galvanised sheet metal Device carrier for fastening of data network technology devices Designation

PU

Device carrier data/communication for BKB

1

Order no.

BKBGTR911

BKBGTR911 BKB device carrier for 2-way electraplan device casing, galvanised sheet metal Designation

PU

Device carrier electraplan 2-way for BKB

1

Order no.

BKBGTR922

BKBGTR922 BKB device carrier for 3-way electraplan device casing, galvanised sheet metal Designation

PU

Device carrier electraplan 3-way for BKB

1

Order no.

BKBGTR923

BKBGTR923

Technical changes reserved

53

tehalit.BKB

Designation

tehalit.BKB Balustrade floor trunking Levelling set 60

tehalit.BKB

8 set screws: - 96 - 145 mm The indicated height range corresponds to the height of the screed. BKBNS60

Designation

PU

Levelling set 96-145 mm for BKB

1

Order no.

BKBNS60

Levelling set 120 8 set screws: - 145 - 210 mm The indicated height range corresponds to the height of the screed.

BKBNS120

Designation

PU

Levelling set 145-210 mm for BKB

1

Order no.

BKBNS120

Levelling set 60 with insulation 8 set screws with insulation for height adjustment: - 96 - 145 mm The indicated height range corresponds to the height of the screed.

BKBNSD60

Designation

PU

Levelling set 96-145 mm w insulation for BKB

1

Order no.

BKBNSD60

Levelling set 120 with insulation 8 set screws with insulation for height adjustment: - 145 - 210 mm The indicated height range corresponds to the height of the screed. Designation

PU

Levelling set 145-210 mm w insulation for BKB

1

BKBNSD120

54

Technical changes reserved

Order no.

BKBNSD120

tehalit.BKB Balustrade floor trunking Earth conductor clamp

Designation

PU

Order no.

Earth conductor clamp, chrome-plated

10

L4187CHRO

L4187CHRO Earthing conductor Pluggable, cross-section 4 mm², for electrical connection of the base profile and upper parts as well as for bypassing moulded parts L4181

Designation

PU

Earthing conductor, L = 150 mm, push-on contact Earthing conductor, L = 300 mm, push-on contact Earthing conductor, L = 600 mm, push-on contact

100 100 25

Order no.

L4181GNGE L4182GNGE L4183GNGE

2-component silicone fire protection foam S90

BS90SET

Cable insulation For installation in walls and floors for fire resistance classification S90 in accordance with DIN4102. Building inspectorate approval: Approval no.: Z19.15-1256 Installation instructions and the certificate of technical approval from the relevant building inspectorate can be downloaded from www.hager.de/downloads. Further data and requirements calculation table can be found in the technical attachments. Designation

PU

Fire protection foam set Fire protection foam can Shaped part 3 adapter spray tubes Valve tongs

1 1 1 1 1

Order no.

BS90SET BS90D BS90F BS90S BS90Z

Sound barrier 1 set = 15 pigtails, pigtail length: 300 mm, ø 30 mm, damping approx. 40 dB, non-combustible, building materials classification A1, not suitable for use as a firewall. L5804

Designation

PU

Sound barrier = 15 pigtails

1

Technical changes reserved

Order no.

L5804

55

tehalit.BKB

For base terminals up to a cross section of 10 mm²

electraplan.BK

electraplan.BK with flexible formwork staples, system overview

4

1 5

8

3

7 6

2

electraplan.BK 1 Basic profile 2 Cover 3 Cross member 4 Blank cover 5 Cover with blanking 6 Side junction box 7 Partition wall 8 Screed anchor

56

Technical changes reserved

electraplan.BK with flexible formwork staples, system overview

electraplan.BK

4

1 5 7

3

6

2

electraplan.BK 1 Basic profile 3 End piece 3 Cross member 4 Blank cover 5 Cover with blanking 6 Side junction box 7 Screed anchor

Technical changes reserved

57

electraplan.BK Trunking overview

electraplan.BK

Trunking with flexible screed casing Trunkings

Nominal size

Outer width mm 166 166 166 166

Trunking height max. mm 70 110 150 190

Levelling range mm 45 - 70 65 - 110 105 - 150 145 - 190

Usable cross-section cm2 77 121 165 209

Max. Line allocation Ø 11 mm, half full 31 50 68 86

BKF150045 BKF150065 BKF150105 BKF150145

150 150 150 150

BKF200045 BKF200065 BKF200105 BKF200145

200 200 200 200

216 216 216 216

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

112 176 240 304

46 72 99 125

62 62 62 62

BKF250045 BKF250065 BKF250105 BKF250145

250 250 250 250

266 266 266 266

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

147 231 315 399

60 95 130 164

62 62 62 62

BKF300045 BKF300065 BKF300105 BKF300145

300 300 300 300

316 316 316 316

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

182 286 390 494

75 118 161 204

62 62 62 62

BKF350045 BKF350065 BKF350105 BKF350145

350 350 350 350

366 366 366 366

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

217 341 465 629

89 140 192 243

62 62 62 62

BKF400045 BKF400065 BKF400105 BKF400145

400 400 400 400

416 416 416 416

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

252 396 540 684

104 163 223 282

62 62 62 62

BKF500045 BKF500065 BKF500105 BKF500145

500 500 500 500

516 516 516 516

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

322 506 690 874

133 209 285 361

62 62 62 62

BKF600045 BKF600065 BKF600105 BKF600145

600 600 600 600

616 616 616 616

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

392 616 840 1064

161 254 347 439

62 62 62 62

58

Technical changes reserved

Page

62 62 62 62

electraplan.BK Trunking overview Trunking with trunking bottom Nominal size

Outer width

Zughöhe mm 28 38 48 58

Levelling range mm 40 - 60 50 - 70 60 - 100 70 - 110

Usable cross-section cm2 37.5 50.9 64.3 77.7

Max. Line allocation Ø 11 mm, half full 15 21 26 32

BKW150040 BKW150050 BKW150060 BKW150070

150 150 150 150

mm 166 166 166 166

BKW200060 BKW200070 BKW200080 BKW200090

200 200 200 200

216 216 216 216

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

88.3 106.7 125.1 143.5

36 44 51 59

64 64 64 64

BKW250060 BKW250070 BKW250080 BKW250090

250 250 250 250

266 266 266 266

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

112.3 135.7 159.1 182.5

46 56 65 75

64 64 64 64

BKW300060 BKW300070 BKW300080 BKW300090

300 300 300 300

316 316 316 316

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

136.3 164.7 193.1 221.5

56 68 79 91

64 64 64 64

BKW350060 BKW350070 BKW350080 BKW350090

350 350 350 350

366 366 366 366

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

160.3 193.7 227.1 260.5

66 80 93 107

64 64 64 64

BKW400060 BKW400070 BKW400080 BKW400090

400 400 400 400

416 416 416 416

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

184.3 222.7 261.1 299.5

76 92 107 123

64 64 64 64

BKW500060 BKW500070 BKW500080 BKW500090

500 500 500 500

516 516 516 516

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

232.3 280.7 329.1 377.5

96 116 136 156

64 64 64 64

BKW600060 BKW600070 BKW600080 BKW600090

600 600 600 600

616 616 616 616

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

280.3 338.7 397.1 455.5

115 139 164 188

64 64 64 64

Technical changes reserved

Page

64 64 64 64

59

electraplan.BK

Trunkings

electraplan.BK Trunking overview

electraplan.BK

Trunking system with flexible screed casing and sealing option Trunkings

Nominal size

Outer width mm 170 170 170 170

Trunking max. mm 70 110 150 190

Levelling range mm 45 - 70 65 - 110 105 - 150 145 - 190

Usable cross-section cm2 77 121 165 209

Max. Line allocation Ø 11 mm, half full 31 50 68 86

BKFD150045 BKFD150065 BKFD150105 BKFD150145

150 150 150 150

BKFD200045 BKFD200065 BKFD200105 BKFD200145

200 200 200 200

220 220 220 220

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

112 176 240 304

46 72 99 125

70 70 70 70

BKFD250045 BKFD250065 BKFD250105 BKFD250145

250 250 250 250

270 270 270 270

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

147 231 315 399

60 95 130 164

70 70 70 70

BKFD300045 BKFD300065 BKFD300105 BKFD300145

300 300 300 300

320 320 320 320

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

182 286 390 494

75 118 161 204

70 70 70 70

BKFD350045 BKFD350065 BKFD350105 BKFD350145

350 350 350 350

370 370 370 370

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

217 341 465 589

89 140 192 243

70 70 70 70

BKFD400045 BKFD400065 BKFD400105 BKFD400145

400 400 400 400

420 420 420 420

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

252 396 540 684

104 163 223 282

70 70 70 70

BKFD500045 BKFD500065 BKFD500105 BKFD500145

500 500 500 500

520 520 520 520

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

322 506 690 874

133 209 285 361

70 70 70 70

BKFD600045 BKFD600065 BKFD600105 BKFD600145

600 600 600 600

620 620 620 620

70 110 150 190

45 - 70 65 - 110 105 - 150 145 - 190

392 616 840 1064

161 254 347 439

70 70 70 70

60

Technical changes reserved

Page

70 70 70 70

electraplan.BK Trunking overview Trunking with trunking bottom and sealing option Nominal size

Outer width

Zughöhe mm 28 38 48

Levelling range mm 40 - 60 50 - 70 60 - 100

Usable cross-section cm2 37.5 50.9 64.3

Max. Line allocation Ø 11 mm, half full 15 21 26

BKWD150040 BKWD150050 BKWD150060

150 150 150

mm 170 170 170

BKWD200060 BKWD200070 BKWD200080 BKWD200090

200 200 200 200

220 220 220 220

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

88.3 106.7 125.1 143.5

36 44 51 59

72 72 72 72

BKWD250060 BKWD250070 BKWD250080 BKWD250090

250 250 250 250

270 270 270 270

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

112.3 135.7 159.1 182.5

46 56 65 75

72 72 72 72

BKWD300060 BKWD300070 BKWD300080 BKWD300090

300 300 300 300

320 320 320 320

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

136.3 164.7 193.1 221.5

56 68 79 91

72 72 72 72

BKWD350060 BKWD350070 BKWD350080 BKWD350090

350 350 350 350

370 370 370 370

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

160.3 193.7 227.1 260.5

66 80 93 107

72 72 72 72

BKWD400060 BKWD400070 BKWD400080 BKWD400090

400 400 400 400

420 420 420 420

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

184.3 222.7 261.1 299.5

76 92 107 123

72 72 72 72

BKWD500060 BKWD500070 BKWD500080 BKWD500090

500 500 500 500

520 520 520 520

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

232.3 280.7 329.1 377.5

96 116 136 156

72 72 72 72

BKWD600060 BKWD600070 BKWD600080 BKWD600090

600 600 600 600

620 620 620 620

48 58 68 78

60 - 100 70 - 110 80 - 120 90 - 130

280.3 338.7 397.1 455.5

115 139 164 188

72 72 72 72

Technical changes reserved

Page

72 72 72

61

electraplan.BK

Trunkings

electraplan.BK - Screed-flush trunking system with flexible screed casing for dry-cleaned floors mm, length 800 mm, fastening bores countersunk on one side to facilitate individual choice of floor coverings - Abutting edge for covering: PC/ABS halogen-free, 0 or 4 mm high, grey colour, flush-mounted - Flexible screed casing: PVC, UV-resistant, highly impactresistant

Nominal size

BKF levelling height b 45 - 70 mm sheet metal

BKF levelling height b 65 - 110 mm sheet metal

BKF levelling height b 105 - 150 mm sheet metal

BKF levelling height b 145 - 190 mm sheet metal

150

BKF150045 PU 24 m

BKF150065 PU 24 m

BKF150105 PU 24 m

BKF150145 PU 24 m

200

BKF200045 PU 24 m

BKF200065 PU 24 m

BKF200105 PU 24 m

BKF200145 PU 24 m

250

BKF250045 PU 24 m

BKF250065 PU 24 m

BKF250105 PU 24 m

BKF250145 PU 24 m

300

BKF300045 PU 24 m

BKF300065 PU 24 m

BKF300105 PU 24 m

BKF300145 PU 24 m

350

BKF350045 PU 24 m

BKF350065 PU 24 m

BKF350105 PU 24 m

BKF350145 PU 24 m

400

BKF400045 PU 24 m

BKF400065 PU 24 m

BKF400105 PU 24 m

BKF400145 PU 24 m

500

BKF500045 PU 24 m

BKF500065 PU 24 m

BKF500105 PU 24 m

BKF500145 PU 24 m

600

BKF600045 PU 24 m

BKF600065 PU 24 m

BKF600105 PU 24 m

BKF600145 PU 24 m

electraplan.BK

- BKF: Complete trunking with flexible screed casing for screed-flush installation in dry rooms with dry-cleaned floors - Floor-flush installation units can be installed from a screed height of 55 mm - Blank covers and covers with blanking: Galvanised sheet metal in accordance with DIN EN 10327, material thickness 3

62

Technical changes reserved

- Trunking levelling height from 30 mm with footfall sound insulation from 45 mm - With factory-fitted levelling clamps, footfall sound insulation and set screws enclosed in accessories package

Material Galvanised sheet metal, Galvanised in accordance with DIN EN 10327

Note - The blank covers are reinforced by load-bearing cross members located underneath them. - Optional snap fastener on the blank cover - The load-bearing capacity for components installed flush with the floor is 2 kn, a small amount of bending is permissible. - Sealing piece with foil as termination for screed-flush trunking, for pushing onto the end of the trunking

Form of delivery Up to width 300 mm, upper parts and lower parts are delivered assembled. Above width 350 mm, for weight reasons, the trunking upper parts are delivered separate.

Sealing piece for BKF Levelling height b Sheet metal BKFV150 PU 1 pc

BKFV200 PU 1 pc

BKFV250 PU 1 pc

BKFV300 PU 1 pc

BKFV350 PU 1 pc

BKFV400 PU 1 pc

BKFV500 PU 1 pc

BKFV600 PU 1 pc

Technical changes reserved

63

electraplan.BK

Standard length 2400 mm

electraplan.BK – screed-flush trunking system with trunking bottom for dry-cleaned floors - Blank covers and covers with blanking: Galvanised sheet metal in accordance with DIN EN 10327, material thickness 3 mm, length 800 mm, fastening bores countersunk on one side to facilitate individual choice of floor coverings - Abutting edge for covering PC/ABS halogen-free, 0 or 4 mm high, grey colour, flush-mounted

- Trunking levelling height from 30 mm with footfall sound insulation from 45 mm

Nominal size

BKW Levelling height b 40 - 60 mm sheet metal

BKW Levelling height b 50 – 70 mm Sheet metal

BKW Levelling height b 60 - 100 mm sheet metal

BKW Levelling height b 70 – 110 mm Sheet metal

BKW Levelling height b 80 – 120 mm Sheet metal

BKW Levelling height b 90 – 130 mm Sheet metal

150

BKW150040 PU 24 m

BKW150050 PU 24 m

BKW150060 PU 24 m

BKW150070 PU 24 m

200

BKW200060 PU 24 m

BKW200070 PU 24 m

BKW200080 PU 24 m

BKW200090 PU 24 m

250

BKW250060 PU 24 m

BKW250070 PU 24 m

BKW250080 PU 24 m

BKW250090 PU 24 m

300

BKW300060 PU 24 m

BKW300070 PU 24 m

BKW300080 PU 24 m

BKW300090 PU 24 m

350

BKW350060 PU 24 m

BKW350070 PU 24 m

BKW350080 PU 24 m

BKW350090 PU 24 m

400

BKW400060 PU 24 m

BKW400070 PU 24 m

BKW400080 PU 24 m

BKW400090 PU 24 m

500

BKW500060 PU 24 m

BKW500070 PU 24 m

BKW500080 PU 24 m

BKW500090 PU 24 m

600

BKW600060 PU 24 m

BKW600070 PU 24 m

BKW600080 PU 24 m

BKW600090 PU 24 m

electraplan.BK

- BKW: Complete trunking with trunking bottom for screedflush installation in dry rooms with dry-cleaned floors - Trunking bottom: 1 mm sheet metal, galvanised in accordance with DIN EN 10327 - Floor-flush installation units can be installed on trunking with an adjustment range of 70 - 110 mm or higher.

64

Technical changes reserved

- With factory-fitted levelling clamps, footfall sound insulation and set screws enclosed in accessories package - Fixed inserted sheet metal partition wall available on request

Material Galvanised sheet metal, galvanised in accordance with DIN EN 10327

Note - The blank covers are reinforced by load-bearing cross members located underneath them. - Optional snap fastener on the blank cover - The load-bearing capacity for components installed flush with the floor is 2kn, a small amount of bending is permissible. - End piece with trunking bottom as termination for screed-flush trunking, for connection to the end of the trunking - With factoryfitted levelling clamps, footfall sound insulation and set screws enclosed

BKW end piece Levelling height b 40 - 60 mm sheet metal

BKW end piece Levelling height b 50 – 70 mm Sheet metal

BKW end piece Levelling height b 60 – 100 mm Sheet metal

BKW end piece Levelling height b 70 – 110 mm Sheet metal

BKWE150040 PU 1 pc

BKWE150050 PU 1 pc

BKWE150060 PU 1 pc

BKWE150070 PU 1 pc

BKWE200060 PU 1 pc

BKW end piece Levelling height b 80 – 120 mm Sheet metal

BKW end piece Levelling height b 90 – 130 mm Sheet metal

BKWE200070 PU 1 pc

BKWE200080 PU 1 pc

BKWE200090 PU 1 pc

BKWE250060 PU 1 pc

BKWE250070 PU 1 pc

BKWE250080 PU 1 pc

BKWE250090 PU 1 pc

BKWE300060 PU 1 pc

BKWE300070 PU 1 pc

BKWE300080 PU 1 pc

BKWE300090 PU 1 pc

BKWE350060 PU 1 pc

BKWE350070 PU 1 pc

BKWE350080 PU 1 pc

BKWE350090 PU 1 pc

BKWE400060 PU 1 pc

BKWE400070 PU 1 pc

BKWE400080 PU 1 pc

BKWE400090 PU 1 pc

BKWE500060 PU 1 pc

BKWE500070 PU 1 pc

BKWE500080 PU 1 pc

BKWE500090 PU 1 pc

BKWE600060 PU 1 pc

BKWE600070 PU 1 pc

BKWE600080 PU 1 pc

BKWE600090 PU 1 pc

Technical changes reserved

Form of delivery Up to width 300 mm, upper parts and lower parts are delivered assembled. Above width 350 mm, for weight reasons, the trunking upper parts are delivered separate.

65

electraplan.BK

Standard length 2400 mm

electraplan.BK – covers for screed-flush trunking systems for dry-cleaned floors

electraplan.BK

- As additional covering, fastening bores countersunk on one side to facilitate individual choice of floor coverings, incl. Fastening screws - Blank covers and covers with blankings for service units

Blankings: GBZ: round 50 mm R06: round 215 mm R10: round 275 mm R12: round 306 mm Q06: square 200 x 200 mm Q08: square 294 x 294 mm Q12: square 244 x 244 mm E04: rectangular 147 x 247 mm E09: rectangular 200 x 253 mm

Standard length 800 mm Material 3 mm galvanised sheet metal, galvanised in accordance with DIN EN 10327

275

Nominal size a

Sheet metal

Cover Blanking for GBZ Sheet metal

150

BKA150800 PU 1 pc

BKA150800GBZ PU 1 pc

200

BKA200800 PU 1 pc

BKA200800GBZ PU 1 pc

250

BKA250800 PU 1 pc

BKA250800GBZ PU 1 pc

300

BKA300800 PU 1 pc

BKA300800GBZ PU 1 pc

BKA300800R06 PU 1 pc

350

BKA350800 PU 1 pc

BKA350800GBZ PU 1 pc

BKA350800R06 PU 1 pc

BKA350800R2 PU 1 pc

BKA350800R10 PU 1 pc

400

BKA400800 PU 1 pc

BKA400800GBZ PU 1 pc

BKA400800R06 PU 1 pc

BKA400800R2 PU 1 pc

BKA400800R10 PU 1 pc

BKA400800R12 PU 1 pc

500

BKA500800 PU 1 pc

BKA500800GBZ PU 1 pc

BKA500800R06 PU 1 pc

BKA500800R2 PU 1 pc

BKA500800R10 PU 1 pc

BKA500800R12 PU 1 pc

600

BKA600800 PU 1 pc

BKA600800GBZ PU 1 pc

BKA600800R06 PU 1 pc

BKA600800R2 PU 1 pc

BKA600800R10 PU 1 pc

BKA600800R12 PU 1 pc

66

Blank cover

Cover Blanking for R06 Sheet metal

Cover Blanking for R2 Sheet metal

Cover Blanking for R10 Sheet metal

Technical changes reserved

Cover Blanking for R12 Sheet metal

electraplan.BK Cover Blanking for Q06 Sheet metal

Cover Blanking for Q08 Sheet metal

Cover Blanking for Q12 Sheet metal

Cover Blanking for E04 Sheet metal

Cover Blanking for E09 Sheet metal

BKA250800E04 PU 1 pc

BKA300800Q06 PU 1 pc

BKA350800Q06 PU 1 pc

BKA300800E04 PU 1 pc

BKA300800E09 PU 1 pc

BKA350800Q12 PU 1 pc

BKA350800E04 PU 1 pc

BKA350800E09 PU 1 pc

BKA400800Q06 PU 1 pc

BKA400800Q08 PU 1 pc

BKA400800Q12 PU 1 pc

BKA400800E04 PU 1 pc

BKA400800E09 PU 1 pc

BKA500800Q06 PU 1 pc

BKA500800Q08 PU 1 pc

BKA500800Q12 PU 1 pc

BKA500800E04 PU 1 pc

BKA500800E09 PU 1 pc

BKA600800Q06 PU 1 pc

BKA600800Q08 PU 1 pc

BKA600800Q12 PU 1 pc

BKA600800E04 PU 1 pc

BKA600800E09 PU 1 pc

Technical changes reserved

67

electraplan.BK – cross members for screed-flush trunking systems for dry-cleaned floors

electraplan.BK

- Cross members for additional load-bearing support underneath blank covers and covers with blankings on screed-flush trunking, fastened with screws in the trunking side profile

Nominal size a

Cross member Sheet metal

- BKTMN: with centre support, set screws need to be ordered separately

Cross member for centre support Sheet metal

150

BKTN150 PU 1 pc

200

BKTN200 PU 1 pc

250

BKTN250 PU 1 pc

BKTMN250 PU 1 pc

300

BKTN300 PU 1 pc

BKTMN300 PU 1 pc

350

BKTN350 PU 1 pc

BKTMN350 PU 1 pc

400

BKTMN400 PU 1 pc

500

BKTMN500 PU 1 pc

600

BKTMN600 PU 1 pc

68

- BKTN: without centre support

Technical changes reserved

Note - Cross members with centre support must be equipped with M8 levelling set screws to avoid unacceptable bending in situ.

electraplan.BK Technical changes reserved

69

electraplan.BK – screed-flush trunking system with flexible screed casing and sealing option ness 3 mm, length 800 mm, fastening bores countersunk on one side to facilitate individual choice of floor coverings - Abutting edge for covering PC/ABS halogen-free, 0 or 4 mm high, grey colour, flush-mounted - Flexible screed casing: PVC, UV-resistant, highly impact-resistant

Nominal size

BKFD Levelling height b 45 - 70 mm Sheet metal

BKFD Levelling height b 65 - 110 mm Sheet metal

BKFD Levelling height b 105 - 150 mm Sheet metal

BKFD Levelling height b 145 - 190 mm Sheet metal

150

BKFD150045 PU 24 m

BKFD150065 PU 24 m

BKFD150105 PU 24 m

BKFD150145 PU 24 m

200

BKFD200045 PU 24 m

BKFD200065 PU 24 m

BKFD200105 PU 24 m

BKFD200145 PU 24 m

250

BKFD250045 PU 24 m

BKFD250065 PU 24 m

BKFD250105 PU 24 m

BKFD250145 PU 24 m

300

BKFD300045 PU 24 m

BKFD300065 PU 24 m

BKFD300105 PU 24 m

BKFD300145 PU 24 m

350

BKFD350045 PU 24 m

BKFD350065 PU 24 m

BKFD350105 PU 24 m

BKFD350145 PU 24 m

400

BKFD400045 PU 24 m

BKFD400065 PU 24 m

BKFD400105 PU 24 m

BKFD400145 PU 24 m

500

BKFD500045 PU 24 m

BKFD500065 PU 24 m

BKFD500105 PU 24 m

BKFD500145 PU 24 m

600

BKFD600045 PU 24 m

BKFD600065 PU 24 m

BKFD600105 PU 24 m

BKFD600145 PU 24 m

electraplan.BK

- BKFD: Complete trunking with flexible screed casing and sealing option for screed-flush installation in dry rooms - Floor-flush installation units can be installed from a screed height of 55 mm - Blank covers and covers with blanking: Galvanised sheet metal in accordance with DIN EN 10327, material thick-

70

Technical changes reserved

- Trunking levelling height from 30 mm with footfall sound insulation from 45 mm - With factory-fitted levelling clamps, sealing tape, footfall sound insulation and set screws enclosed

Material Galvanised sheet metal, galvanised in accordance with DIN EN 10327

Note - The blank covers are reinforced by load-bearing cross members located underneath them. - Optional snap fastener on the blank cover - The load-bearing capacity for components installed flush with the floor is 2kn, a small amount of bending is permissible. - End piece with foil as termination for screed-flush trunking, for connection to the end of the trunking - With factory-fitted levelling clamps, sealing tape, footfall sound insulation and set screws enclosed in accessories package

Endstück BKFD Levelling height b 45 - 70 mm Sheet metal

Endstück BKFD Levelling height b 65 - 110 mm Sheet metal

Endstück BKFD Levelling height b 105 -150 mm Sheet metal

Endstück BKFD Levelling height b 145 - 190 mm Sheet metal

BKFDE150045 PU 1 pc PrGr T07 95,50 €/pc

BKFDE150065 PU 1 pc PrGr T07 96,50 €/pc

BKFDE150105 PU 1 pc PrGr T07 98,20 €/pc

BKFDE150145 PU 1 pc PrGr T07 100,20 €/pc

BKFDE200045 PU 1 pc PrGr T07 99,70 €/pc

BKFDE200065 PU 1 pc PrGr T07 100,80 €/pc

BKFDE200105 PU 1 pc PrGr T07 102,40 €/pc

BKFDE200145 PU 1 pc PrGr T07 104,60 €/pc

BKFDE250045 PU 1 pc PrGr T07 104,00 €/pc

BKFDE250065 PU 1 pc PrGr T07 105,10 €/pc

BKFDE250105 PU 1 pc PrGr T07 106,70 €/pc

BKFDE250145 PU 1 pc PrGr T07 108,90 €/pc

BKFDE300045 PU 1 pc

BKFDE300065 PU 1 pc

BKFDE300105 PU 1 pc

BKFDE300145 PU 1 pc

BKFDE350045 PU 1 pc

BKFDE350065 PU 1 pc

BKFDE350105 PU 1 pc

BKFDE350145 PU 1 pc

BKFDE400045 PU 1 pc

BKFDE400065 PU 1 pc

BKFDE400105 PU 1 pc

BKFDE400145 PU 1 pc

BKFDE500045 PU 1 pc

BKFDE500065 PU 1 pc

BKFDE500105 PU 1 pc

BKFDE500145 PU 1 pc

BKFDE600045 PU 1 pc

BKFDE600065 PU 1 pc

BKFDE600105 PU 1 pc

BKFDE600145 PU 1 pc

Technical changes reserved

Form of delivery Up to width 300 mm, upper parts and lower parts are delivered assembled. Above width 350 mm, for weight reasons, the trunking upper parts are delivered separate.

71

electraplan.BK

Standard length 2400 mm

electraplan.BK – screed-flush trunking system with trunking bottom and sealing option - Blank covers and covers with blanking: Galvanised sheet metal in accordance with DIN EN 10327, material thickness 3 mm, length 800 mm, fastening bores countersunk on one side to facilitate individual choice of floor coverings - Abutting edge for covering: PC/ABS halogen-free,

0 or 4 mm high, grey colour, flush-mounted - Trunking levelling height from 30 mm with footfall sound insulation from 45 mm - With factory-fitted levelling clamps, sealing tape, footfall sound insulation and set screws enclosed - Fixed inserted sheet metal partition wall available on request

Nominal size

BKWD Levelling height b 40 - 60 mm Sheet metal

BKWD Levelling height b 50 - 70 mm Sheet metal

BKWD Levelling height b 60 - 100 mm Sheet metal

BKWD Levelling height b 70 - 110 mm Sheet metal

BKWD Levelling height b 80 - 120 mm Sheet metal

BKWD Levelling height b 90 - 130 mm Sheet metal

150

BKWD150040 PU 24 m

BKWD150050 PU 24 m

BKWD150060 PU 24 m

electraplan.BK

- BKWD: Complete trunking with trunking bottom and sealing option for screed-flush installation in dry rooms - Trunking bottom: 1 mm sheet metal, galvanised in accordance with DIN EN 10327 - Floor-flush installation units can be installed on trunking with an adjustment range of 70 - 110 mm or higher.

200

BKWD200060 PU 24 m

BKWD200070 PU 24 m

BKWD200080 PU 24 m

BKWD200090 PU 24 m

250

BKWD250060 PU 24 m

BKWD250070 PU 24 m

BKWD250080 PU 24 m

BKWD250090 PU 24 m

300

BKWD300060 PU 24 m

BKWD300070 PU 24 m

BKWD300080 PU 24 m

BKWD300090 PU 24 m

350

BKWD350060 PU 24 m

BKWD350070 PU 24 m

BKWD350080 PU 24 m

BKWD350090 PU 24 m

400

BKWD400060 PU 24 m

BKWD400070 PU 24 m

BKWD400080 PU 24 m

BKWD400090 PU 24 m

500

BKWD500060 PU 24 m

BKWD500070 PU 24 m

BKWD500080 PU 24 m

BKWD500090 PU 24 m

600

BKWD600060 PU 24 m

BKWD600070 PU 24 m

BKWD600080 PU 24 m

BKWD600090 PU 24 m

72

Technical changes reserved

Material Galvanised sheet metal, galvanised in accordance with DIN EN 10327

Note - The blank covers are reinforced by load-bearing cross members located underneath them. - Optional snap fastener on the blank cover - The load-bearing capacity for components installed flush with the floor is 2kn, a small amount of bending is permissible. - End piece with trunking bottom as termination for screed-flush trunking, for connection to the end of the trunking - With factory-fitted levelling clamps, sealing tape, footfall sound insulation and set screws enclosed in accessories package

Endstück BKWD Levelling height b 40 - 60 mm Sheet metal

Endstück BKWD Levelling height b 50 - 70 mm Sheet metal

Endstück BKWD Levelling height b 60 - 100 mm Sheet metal

BKWDE150040 PU 1 pc

BKWDE150050 PU 1 pc

BKWDE150060 PU 1 pc

Endstück BKWD Levelling height b 70 - 110 mm Sheet metal

Endstück BKWD Levelling height b 80 - 120 mm Sheet metal

Endstück BKWD Levelling height b 90 - 130 mm Sheet metal

BKWDE200060 PU 1 pc

BKWDE200070 PU 1 pc

BKWDE200080 PU 1 pc

BKWDE200090 PU 1 pc

BKWDE250060 PU 1 pc

BKWDE250070 PU 1 pc

BKWDE250080 PU 1 pc

BKWDE250090 PU 1 pc

BKWDE300060 PU 1 pc

BKWDE300070 PU 1 pc

BKWDE300080 PU 1 pc

BKWDE300090 PU 1 pc

BKWDE350060 PU 1 pc

BKWDE350070 PU 1 pc

BKWDE350080 PU 1 pc

BKWDE350090 PU 1 pc

BKWDE400060 PU 1 pc

BKWDE400070 PU 1 pc

BKWDE400080 PU 1 pc

BKWDE400090 PU 1 pc

BKWDE500060 PU 1 pc

BKWDE500070 PU 1 pc

BKWDE500080 PU 1 pc

BKWDE500090 PU 1 pc

BKWDE600060 PU 1 pc

BKWDE600070 PU 1 pc

BKWDE600080 PU 1 pc

BKWDE600090 PU 1 pc

Technical changes reserved

Form of delivery Up to width 300 mm, upper parts and lower parts are delivered assembled. Above width 350 mm, for weight reasons, the trunking upper parts are delivered separate.

73

electraplan.BK

Standard length 2400 mm

electraplan.BK

electraplan.BK – covers for screed-flush trunking systems with sealing option

Nominal size a

- As additional covering, fastening bores countersunk on one side to facilitate individual choice of floor coverings, incl. Fastening screws - Blank covers and covers with blankings for pedestal boxes and service units VANR12

Blankings GBZ: round 50 mm R12: round 306 mm

Blank cover

Cover Blanking for R2 Sheet metal

Sheet metal

Cover Blanking for GBZ Sheet metal

150

BKAD150 PU 1 pc

BKAD150GBZ PU 1 pc

200

BKAD200 PU 1 pc

BKAD200GBZ PU 1 pc

250

BKAD250 PU 1 pc

BKAD250GBZ PU 1 pc

300

BKAD300 PU 1 pc

BKAD300GBZ PU 1 pc

350

BKAD350 PU 1 pc

BKAD350GBZ PU 1 pc

BKAD350800R2 PU 1 pc

400

BKAD400 PU 1 pc

BKAD400GBZ PU 1 pc

BKAD400800R2 PU 1 pc

BKAD400R12 PU 1 pc

500

BKAD500 PU 1 pc

BKAD500GBZ PU 1 pc

BKAD500800R2 PU 1 pc

BKAD500R12 PU 1 pc

600

BKAD600 PU 1 pc

BKAD600GBZ PU 1 pc

BKAD600800R2 PU 1 pc

BKAD600R12 PU 1 pc

74

Cover Blanking for R12 Sheet metal

Technical changes reserved

Standard length 800 mm Material 3 mm galvanised sheet metal, Galvanised in accordance with DIN EN 10327

electraplan.BK - cross members for screed-flush trunking systems with sealing option - BKTMD: with centre support, set screws need to be ordered separately

Nominal size

Cross member

Note - Cross members with a centre support must be equipped with set screws M8 on-site to prevent excessive bending. electraplan.BK

- Cross members for additional load-bearing support underneath blank covers and covers with blankings on screed-flush trunking, fastened with screws in the trunking side profile - BKTD: without centre support

Sheet metal

Cross member for centre support Sheet metal

150

BKTD150 PU 1 pc

200

BKTD200 PU 1 pc

250

BKTD250 PU 1 pc

BKTMD250 PU 1 pc

300

BKTD300 PU 1 pc

BKTMD300 PU 1 pc

350

BKTD350 PU 1 pc

BKTMD350 PU 1 pc

400

BKTMD400 PU 1 pc

500

BKTMD500 PU 1 pc

600

BKTMD600 PU 1 pc

Technical changes reserved

75

electraplan.BK Junction boxes and accessories

electraplan.BK

Junction box with foil

BKSAB00

Properties: - Junction box for side mounting on floor trunking for dry rooms with dry or wet-cleaned flooring, for the mounting of installation units (flush with the floor or protruding above it) with fitting frame - Outer dimension: 411 x 388 mm - Junction boxes avoid narrowing of the trunking cross-section, which is otherwise unavoidable when installation units are mounted directly in the trunking. - A levelling clamp from the existing trunking and a levelling set are required for the installation. - The levelling set needs to be ordered separately. - Available with trunking bottom on request Designation

Blanking

Side junction box for floor trunking, blank Side junction box for floor trunking with GBZ blanking Side junction box for floor trunking with E04 blanking Side junction box for floor trunking with E09 blanking Side junction box for floor trunking with Q06 blanking Side junction box for floor trunking with R06 blanking Side junction box for floor trunking with Q12 blanking Side junction box for floor trunking with R10 blanking Side junction box for floor trunking with Q08 blanking Side junction box for floor trunking with R12 blanking

Ø [mm] a [mm]

b [mm]

50 147 200 200

247 253 200

244

244

294

294

215 275 306

PU

1 1 1 1 1 1 1 1 1 1

Order no.

BKSAB00 BKSAG00 BKSAE04 BKSAE09 BKSAQ06 BKSAR06 BKSAQ12 BKSAR10 BKSAQ08 BKSAR12

Levelling set for junction box Properties: - Levelling set comprising 3 levelling clamps, 4 set screws with insulating mounts, 3 screed anchors Designation

BKSAN045070

76

Height adjustment range [mm]

Levelling set for BKSA h.-adj. range 45- 70 Levelling set for BKSA h.-adj. range 65-110 Levelling set for BKSA h.-adj. range 105-150 Levelling set for BKSA h.-adj. range 145-190

Technical changes reserved

PU

1 1 1 1

Order no.

BKSAN045070 BKSAN065110 BKSAN105150 BKSAN145190

electraplan.BK Partition walls and accessories

BKTWK16

Properties: - Partition wall for separating trunking into compartments, accessory for screed-flush trunking - Includes 4 partition wall feet for attachment with anchors to the bare floor - Total height with partition wall feet = nominal height a + 2.5 mm - Length: 2000 mm Designation

PU

Partition wall, nominal height 16 mm, L = 2000 mm, PS Partition wall, nominal height 31mm, L = 2000 mm, PS Partition wall, nominal height 46mm, L = 2000 mm, PS Partition wall, nominal height 61mm, L = 2000 mm, PS Partition wall, nominal height 76mm, L = 2000 mm, PS Partition wall, nominal height 91mm, L = 2000 mm, PS

1 1 1 1 1 1

Order no.

BKTWK16 BKTWK31 BKTWK46 BKTWK61 BKTWK76 BKTWK91

Partition wall foot made of PS Properties: - If required

BKTWF00

Designation

PU

PS partition wall foot for PS partition wall

1

Order no.

BKTWF00

Partition wall made of sheet metal Properties: - Partition wall for separating trunking into compartments, accessory for screed-flush trunking - For attachment to the bare floor with anchors - Length: 2400 mm

BKTWS20

Material: - 1 mm galvanised sheet metal, galvanised in accordance with DIN EN 10327 Designation

PU

Partition wall, nominal height 20 mm, L = 2400 mm, sheet metal Partition wall, nominal height 35mm, L = 2400 mm, sheet metal Partition wall, nominal height 50mm, L = 2400 mm, sheet metal Partition wall, nominal height 65mm, L = 2400 mm, sheet metal Partition wall, nominal height 80mm, L = 2400 mm, sheet metal Partition wall, nominal height 95mm, L = 2400 mm, sheet metal Partition wall, nominal height 110mm, L = 2400 mm, sheet metal

1 1 1 1 1 1 1

Technical changes reserved

Order no.

BKTWS20 BKTWS35 BKTWS50 BKTWS65 BKTWS80 BKTWS95 BKTWS110

77

electraplan.BK

Partition wall made of PS

electraplan.BK Accessories

electraplan.BK

Earth conductor for earthing of the trunking system Properties: - Screwed to straight trunking connector, flexible wire 2.5 mm², 200 mm long, green/yellow - 1 x ring cable lug, 1 x wire end ferrule - Suitable for screed-flush trunking systems for dry-cleaned floors BKZSA200

Designation

PU

Earth conductor for earthing of the underfloor trunking

1

Order no.

BKZSA200

Earth conductor, connecting clamp Properties: - Connecting terminal with inner profile slot, flexible wire 4 mm², 200 mm long, green/yellow - Suitable for screed-flush floor trunking with sealing option

BKZSAK00

Designation

PU

Erdungsklemme zu Bodenkanal BK

1

Order no.

BKZSAK00

Sponge rubber strip Properties: - Sponge rubber strip for absorbing expansion pressure, self-adhesive, for installation on-site on the side profiles - 2 metres of sponge rubber required for each metre of trunking - Always coordinate use of the sponge rubber strips with the screed layer. BKZM203

Designation

PU

Sponge rubber strip, 20 x 3mm, self-adhesive

1

Order no.

BKZM203

Abutting edge for covering Properties: - If required - The abutting edge for the covering can be used visibly (height 4 mm) or concealed by the floor covering. - 2 metres of abutting edge for covering required for each metre of trunking - Abutting edge for covering with a height of 3.2 mm available on request Material: - PC/ABS halogen-free BKZBSK7011

78

Available colours: - RAL7011, iron grey - RAL9005, deep black Designation

PU

Abutting edge for covering height 4 mm PC/ABS hal.-free, eg Abutting edge for covering height 4 mm PC/ABS hal.-free, ts

1 1

Technical changes reserved

Order no.

BKZBSK7011 BKZBSK9005

electraplan.BK Accessories

Properties: - To meet additional demand - Remove factory-fitted abutting edge - 2 metres of butt joint cover required for each metre of trunking

BKZBSA7011

Designation

PU

Butt joint cover PVC iron grey

1

Order no.

BKZBSA7011

Screed anchor Properties: - For stabilising the trunking side profiles - For snapping into the trunking side profile - Max. installation gap between screed anchors is 800 mm along the side profile. Material: - PA6 BKZEA00 Designation

PU

Screed anchor, plastic PA6

1

Order no.

BKZEA00

Connection set Properties: - For use as additional installation material in order to create 90° branches on-site using the existing trunking material. - Comprises 2 outer angled connectors 18 mm, 2 straight trunking connectors and 2 screws M5 x 12 Designation

PU

Connection set for 90 deg. branch, steel

1

Order no.

BKZVS90

BKZVS90

Technical changes reserved

79

electraplan.BK

Butt joint cover:

electraplan.BK Accessories Trunking connector straight

electraplan.BK

Properties: - If required Designation

PU

Underfloor trunking connector straight 180 deg. steel

1

Order no.

BKZKV180

BKZKV180 Trunking connector angled Properties: - If required

BKZKV090

Designation

PU

Underfloor trunking connector angled 90 degrees, steel

1

Order no.

BKZKV090

Levelling clamp Properties: - Levelling clamp for mounting set screws - External assembly on the side profile of screed-flush trunking with a straight trunking connector and two screws - Maximum installation distance between levelling clamps 800 mm along the trunking side profile Material: Steel, electroplated BKZN030

80

From height of ducting with footfall sound insulation mountings BKZN30 45 mm BKZN50 65 mm Designation

PU

Lev. clamp for mounting lev. studs Lev. height 45 Lev. clamp for mounting lev. studs Lev. height 65

1 1

Technical changes reserved

Order no.

BKZN030 BKZN050

electraplan.BK Accessories Set screws

BKZNS25

electraplan.BK

Properties: - Set screw M8 for elevating the screed-flush trunking, for screwing into the levelling clamp or cross member Note: - Set screws that protrude above the upper edge of the screed or cross member must be shortened. - Other heights available on request Designation

Länge a

Set screw M8 x 25, levelling height 25 mm Set screw M8 x 30, levelling height 30mm Set screw M8 x 35, levelling height 35mm Set screw M8 x 40, levelling height 40mm Set screw M8 x 45, levelling height 45mm Set screw M8 x 50, levelling height 50mm Set screw M8 x 55, levelling height 55mm Set screw M8 x 60, levelling height 60mm Set screw M8 x 65, levelling height 65mm Set screw M8 x 70, levelling height 70mm Set screw M8 x 75, levelling height 75mm Set screw M8 x 80, levelling height 80mm Set screw M8 x 85, levelling height 85mm Set screw M8 x 90, levelling height 90mm Set screw M8 x 100, levelling height 100mm Set screw M8 x 120, levelling height 120mm Set screw M8 x 140, levelling height 140mm Set screw M8 x 160, levelling height 160mm

PU

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Order no.

BKZNS25 BKZNS30 BKZNS35 BKZNS40 BKZNS45 BKZNS50 BKZNS55 BKZNS60 BKZNS65 BKZNS70 BKZNS75 BKZNS80 BKZNS85 BKZNS90 BKZNS100 BKZNS120 BKZNS140 BKZNS160

Lock nut M8 Properties: - Nut M8 for locking set screws in cross members BKZKM80

Designation

PU

Lock nut M8 for locking h.-adj. pin

1

Order no.

BKZKM80

Retaining tab with insulating mount Properties: - Retaining tab with insulating mount for fastening of the screed-flush trunking on the bare floor for footfall sound-insulated installation of set screws M8

BKZHP00

Material: - Retaining tabs made of galvanised steel in accordance with DIN EN 10327 - Insulating mount made of plastic Note: - When using retaining tabs with insulating mounts, the minimum installation height for the trunking is 45 mm. Designation

PU

Retaining tab made of steel, with insulating mount

1

Technical changes reserved

Order no.

BKZHP00

81

electraplan.BK Accessories

electraplan.BK

Insulating mount for cross member Properties: - Insulating mount for footfall sound-insulated mounting of set screws M8 in cross members - The insulating mount increases the levelling height by 5 mm BKZNSD0

Designation

PU

Insulating mount for set screws

1

Order no.

BKZNSD0

Suction lifter, max. load capacity 20 kg Properties: - For lifting blank covers Designation

PU

Suction lifter for blank covers (max. weight 20 kg)

1

Order no.

BKZSH20

BKZSH20 Suction lifter, max. load capacity 30 kg Properties: - For lifting blank covers Designation

PU

Suction lifter for blank covers (max. weight 30 kg)

1

Order no.

BKZSH30

BKZSH30 Claw lifter, max. load capacity 30 kg Properties: - For lifting blank covers Designation

PU

Claw lifter for blank covers, max. 30 kg

1

Order no.

BKZKH30

BKZKH30 Stapler Properties: - Robust version for screed film formwork staples Designation

PU

Stapler for screed film staples

1

Order no.

BKZHZ10

BKZHZ10 Staples Properties: - Staples for stapler BKZHZ10 - 1 piece = 5000 staples BKZHZ12

82

Designation

PU

Staples 12 mm for stapler BKZHZ10

1

Technical changes reserved

Order no.

BKZHZ12

tehalit.BKB Installation instructions

Product features • Suitable for dry-cleaned floors in accordance with DIN EN 50085 • Suitable for floor coverings with a thickness ranging from 5 to 25 mm • The upper part can be covered with dry-cleaned floor coverings (carpet, parquet flooring, laminate,…) or with wet-cleaned floor coverings (natural stone, marble, tiles,…). Due to the open design, the trunking system is only suitable for dry-cleaned rooms. •F  loor covering is glued onto the cover •R  ecommended minimum height of trunking = minimum screed height = 96 mm •D  o not forget the edge insulation strip between the trunking and the screed! • It  may be necessary to install sound insulation at the transition between office units (sound insulation barrier, product no. L5804, see catalogue ‘Leitungsführung + Raumanschlusssysteme’) •A  trunking firewall (BS90SET) must be installed when routing the trunking through fire safety walls •O  ther trunking heights and widths available on request •H  eight levelling via internally accessible adjustment screws • Easy access to cables and sockets is provided via the removable upper part and via the cable outlet on the wall side on upper parts with a brush. Length of the upper parts: 1 m, length of the trunking bottom part: 2 m. • Also available as closed trunking without a cable outlet for installation in areas that people walk in •W  ithstands point loads of up to 150 kg (in accordance with the relevant standard) • Separate  delivery of the lower part (always with fitting frame) and 3 different upper parts (with brush, closed, with brush and LED compartment)

Installation concept Preliminary building works phase 1. Installation of the tehalit.BKB system along outer walls or glass fronts in the screed flooring. If possible, a direct connection should be made between the tehalit.BKB system and the cable distribution room or the sub-distribution. 2. Basic installation of the energy and data network infrastructure in the tehalit.BKB system via group connection points. The distribution and number of group connection points depends on the required volume of equipment in the office space (at least 1 group connection point for every 20 to 40 m²). 3. Ensure the installation is compliant with the following standards by using group connection points or conventional connections: - Energy distribution systems: DIN VDE 0634 Part 1 and Part 2, DIN VDE 0100 (in particular Part 520), DIN VDE 0105, - Data network systems: Structured cabling in accordance with EN 50173-1, EN 50173-4, EN 50174-2 Final construction phase 1. Individual installation only once the room layout and usage have been defined 2. Connection of consumers close to walls directly via the group connection points (no additional installation components required) 3. Connection of consumers out in the open using additional Hager system components 4. Pluggable connection systems for safe and reliable installations Usage phase 5. Flexible and quick changes can be made to the energy and data cabling if the room layout or usage change. 6. Optional installation of plinths

Advantages • Investors  can split investment requirements into separate construction and building equipment management phases. • Users benefit from great application and upgrade flexibility with an almost invisible energy and data network infrastructure • Simplified planning process through integration of group connection points or device installation • Separate  delivery of upper and lower parts – allowing basic installation in the preliminary building works phase and completion in the final construction phase • Suitable  upper parts can be used freely to match the final placement of furniture. • Upper  and lower parts are delivered separately, but the lower part is always supplied with a fitting frame to prevent the risk of personal injury during preliminary building works. • Installation depends on the way the office space is divided up and used. • Easy  options for changing the energy and data network infrastructure once the system is in use. • Removable  covers offer access to the installation space. •C  an be combined with Hager system components • Also  suitable for use in the home for energy, media and data connection systems+ Device installation •G  roup connection points for energy and data network •A  ll products from the installation device range, e. g. - Energy distribution - Sockets - Overvoltage protection - Network connections - Antenna sockets - Also suitable for installation of Electraplan devices Line occupancy (guide values) •C  ompartment 1: 31 x ø11 mm; e. g. 3 x 1.5 mm² •C  ompartment 2: 25 x ø11 mm; e. g. 3 x 1.5 mm²

Technical changes reserved

83

tehalit.BKB

tehalit.BKB is designed for installation along walls or window fronts for screed-flush floor installations. Installation with a closed upper part is also possible within a room. The trunking system comes with an upper part with a closed design, a brush and an LED chamber with brush.

tehalit.BKB

tehalit.BKB Installation sequence for the trunking system

1. S  crew in the set screws with or without insulating mounts. 2. A  lign the trunking lower part or inner/outer corner on the wall side.

3. Joints are connected via couplings. The ends of the trunking are sealed off with end pieces. No screed must be allowed to penetrate inside the trunking. A conductive connection is established between the coupling and the lower parts using the screws enclosed in the packaging of the coupling.

4. Levelling of the trunking. The trunking itself forms the binding setting edge for the screed, so the levelling process must be coordinated with the company laying the screed. Minimum recommendation: 4 levelling screws per running meter.

5. S  ecure the trunking on the bare floor using fastening screws. Minimum recommendation: 2 fastening screws per running meter. 6. Lay the fitting frame in position.

7. If necessary connect empty tubes; open the cut-outs beforehand with a slotted screwdriver. Empty pipes can be connected on four sides.

8. Screw in the fitting frame using the drilling screws enclosed with the trunking (in the attached foil packaging). These are screwed directly through the bores in the fitting frame into the support of the lower trunking part (without pre-drilling).

8. A  ttach the wall insulation strip on the side of the trunking facing the screed (make sure that no screed runs under the trunking). Special precautions must be taken when using floating screed, hot screed or aggressive screed. Depending on the floor covering (e. g. liquid material) it may be necessary to consult the manufacturer.

9 If necessary, support the side of the trunking facing the screed to prevent the side wall from bending under the pressure of the screed. The screed layer needs to work the screed cleanly and carefully up to the level of the top edge of the trunking. Make sure that no screed or parts of the floor covering (e. g. liquid material) can run into the trunking.

10. Screed installation

84

Technical changes reserved

tehalit.BKB Installation sequence for the trunking system 11. All metallic parts of the trunking system must be covered by VDE-compliant protection measures. 12. Application of the floor covering (0-25 mm).

tehalit.BKB

13. Floor covering adjustment – version 1 with brush: The outlet brush supplied with the upper part is attached to the wall side of the trunking lower part and adjusted in the same way as the floor covering stop attached to the trunking lower part to the corresponding height of the floor covering by pushing it upward or downward, after which it is then tightened in place using a 3-mm Allen key (not included in the delivery package). 14. Floor covering adjustment – version 2 closed: The floor covering stop supplied with the upper part and the support for the upper part are attached to the wall side of the trunking lower part and adjusted in the same way as the floor covering stop attached to the trunking lower part to the corresponding height of the floor covering by pushing them upward or downward, after which they are then tightened in place using a 3-mm Allen key (not included in the delivery package).s Note: the “support rake” (system carrier) in the lower part needs to be moved to allow the upper part to fit. 15. F  loor covering adjustment – version 2 with LED: The outlet brush supplied with the upper part is attached to the wall side of the trunking lower part and adjusted in the same way as the floor covering stop attached to the trunking lower part to the corresponding height of the floor covering by pushing it upward or downward, after which it is then tightened in place using a 3-mm Allen key (not included in the delivery package). Note: the “support rake” (system carrier) in the lower part needs to be moved to allow the upper part to fit correctly. Advantages of the tehalit.BKB system The balustrade floor trunking offers many advantages in day-to-day use: even in areas without walls, connections can be made available wherever they are required. The installation is concealed and therefore has no impact on the overall appearance of the office space. Excess connecting cable lengths or data network components can be easily hidden in the trunking, so there are no loose lines that get in the way in the room. If you decide to change the way the office space is used at a later date, this is no problem thanks to the removable covers of the tehalit.BKB system, which offer easy access to lines, devices and group collection points. Retrofit installations are thus possible at any time. The selection of upper parts can be adapted at any time to meet the changing requirements of tenants or owners.

Technical changes reserved

85

tehalit.BKB

tehalit.BKB Installation sequence for the trunking system

1. T  o produce the T-piece, you will only need the shaped part shown above and a jig saw to create the 250 mm cut-out in the trunking. Caution! Before cutting out the marked cut-out, remove the support for the upper part and the floor stop rail. These two parts are refitted after completion of the cut-out to ensure optimum support for the upper part and to achieve a clean transition to the floor covering.

2. The tabs protruding flat to the rear are inserted into the trunking lower part that is to be connected and then screwed to the trunking using the enclosed self-tapping screws.

3. The tabs protruding to the sides are inserted into the trunking lower part that is to be branched off and screwed into the trunking with the enclosed drilling screws.

4. T  he trunking lower parts are aligned once the screws have been screwed in.

5. The stop profiles are then installed.

6. Installation of the fitting frame.

86

Technical changes reserved

tehalit.BKB Fire protection, sound barrier

Form of delivery: BS90SET comprising of 1 Fire protection foam can (BS90D) 1 Shaped part (BS90F) 1 Valve tongs (BS90Z) 3 Spray tubes with adapter (BS90S) 2 Identification signs 1 AbZ, approval no.: Z19.15-1256 1 Installation instructions

tehalit.BKB

Cable insulation For installation in walls and floors for fire resistance classification S90 in accordance with DIN4102. Building inspectorate approval: Approval no.: Z19.15-1256 Min. firewall length 150 mm

BS90S 3 Spray pipes with adapter

Yield: approx. 2,100 cm³ BS90D 1 Fire safety foam can (Only to be used in conjunction with valve tongs BS90Z and spray tubes BS90S)

BS90Z 1 Valve tongs

Yield: approx. 900 cm³

BS90F 1 Shaped part Yield: approx. 1,200 cm³

2-component silicone fire protection foam S90 Requirements calculation table for cable fire partitioning Trunking type

Volume in cm³

Trunking without line occupancy

Trunking with maximum line occupancy

BKB25085

3.188

1.0 set + 1.0 socket

1.4 socket

Sound barrier Sound barrier L5804 Maximum fill level of empty trunking Trunking types Pigtails BKB2508525

Technical changes reserved

87

electraplan.BK Order number system Floor trunking Type

Trunking width Nominal size

Levelling range

BK = floor trunking

X

Y

Z

F = with foil W = with trunking bottom

150 200 250 300 350 400 500 600

(foil) 045 = 45 - 70 mm 065 = 65 - 110 mm 105 = 105 - 150 mm 145 = 145 - 190 mm

tehalit.BKB

Identifier

FD = with foil and sealing option WD = with trunking bottom and sealing option

(trunking bottom) 040 = 40 - 60 mm 050 = 50 - 70 mm 060 = 60 - 100 mm 070 = 70 - 110 mm 080 = 80 - 120 mm 090 = 90 - 130 mm

Floor trunking sealing end piece Identifier

Type

Type

Trunking width Nominal size

Levelling range

BK = floor trunking

W

X

Y

Z

F = with foil W = with trunking bottom

V = sealing piece E = end piece

150 200 250 300 350 400 500 600

(trunking bottom) 040 = 40 - 60 mm 050 = 50 - 70 mm 060 = 60 - 100 mm 070 = 70 - 110 mm 080 = 80 - 120 mm 090 = 90 - 130 mm

FD = with foil and sealing option WD = with trunking bottom and sealing option

Floor trunking covers Identifier

Type

with sealing option

Trunking width Nominal size

Type of blanking

BK = floor trunking

W

X = standard (without sealing tape) D = for sealing tape

Y

Z

150 200 250 300 350 400 500 600

= without blanking GBZ = blanking GBZ round 50 mm R06 = blanking R06 round 215 mm R10 = blanking R10 round 275 mm R12 = blanking R12 round 306 mm Q06 = blanking Q06 200 x 200 mm Q08 = blanking Q08 294 x 294 mm Q12 = blanking Q12 244 x 244 mm E04 = blanking E04 147 x 247 mm E09 = blanking E09 200 x 253 mm

A = cover

Floor trunking cross members Identifier

Type

with sealing option

Trunking width Nominal size

BK = floor trunking

X

Y

Z

T = cross member TM = cross member with centre support

N = standard (without sealing strip) D = for sealing tape

150 200 250 300 350 400 500 600

88

Technical changes reserved

electraplan.BK Order number system

Identifier

Type

Type of blanking

BK = floor trunking

Y

Z

SA = side junction box

B00 = without blanking G00 = blanking GBZ round 50 mm R06 = blanking R06 round 215 mm R10 = blanking R10 round 275 mm R12 = blanking R12 round 306 mm Q06 = blanking Q06 200 x 200 mm Q08 = blanking Q08 294 x 294 mm Q12 = blanking Q12 244 x 244 mm E04 = blanking E04 147 x 247 mm E09 = blanking E09 200 x 253 mm

tehalit.BKB

Floor trunking junction boxes

Floor trunking junction boxes – levelling set Identifier

Type

Addition

Levelling range

BK = floor trunking

X

Y

Z

SA = side Junction box

N = levelling set

045070 = 45 - 70 mm 065110 = 65 - 110 mm 105150 = 105 - 150 mm 145190 = 145 - 190 mm

Floor trunking partition walls Identifier

Type

Material

Nominal height

BK = floor trunking

X

Y

Z

TW = partition wall

K = plastic - PS F00 = plastic foot S = steel panel

(plastic) 16 = 16 mm – for trunking height 30 mm 31 = 31 mm – for trunking height 45 mm 46 = 46 mm – for trunking height 60 mm 61 = 61 mm – for trunking height 75mm 76 = 76 mm – for trunking height 90 - 100 mm 91 = 91 mm – for trunking height 105 - 120 mm (sheet metal) 20 = 20 mm – for trunking height 45 mm 35 = 35 mm – for trunking height 60 mm 50 = 50 mm – for trunking height 75 mm 65 = 65 mm – for trunking height 90 mm 80 = 80 mm – for trunking height 100 mm 95 = 95 mm – for trunking height 105 mm 110 = 110 mm – for trunking height 120 mm

Floor trunking accessories Identifier

Type

Type

Colour/angle/height/length

BK = floor trunking

X

Y

Z

Z = accessories

SA = earth connection SAK00 = earth conductor clamp M = sponge rubber strips

200

= length 200 mm

203

= 20 x 3 mm

BSK = abutting edge for covering

7011 9005

= RAL 7011, iron grey = RAL 9005, deep black

BSA EA00 VS KV

= butt joint cover = screed anchor = connection set = trunking connector

7011

= RAL 7011, iron grey

N

= levelling clamp

NS KM HP00 NSD0 SH

= set screw = lock nut = retaining tab = soundproofing mount for set screws = suction lifter 20 30 = claw lifter 30

KH

Technical changes reserved

90 = angled, 90 degrees 180 = straight, 180 degrees 090 = angled, 90 degrees 030 = from trunking height 30 050 = from trunking height 50 25 - 160 = levelling height 80 = for M8 = load-bearing capacity up to 20 kg = load-bearing capacity up to 30 kg = load-bearing capacity up to 30 kg

89

electraplan.BK Flush-floor trunking system

tehalit.BKB

General description The screed-flush trunking system offers covers that can be opened continuously along the full length of the trunking. The screed is installed flush to the top of the trunking. The height of the complete screed-flush trunking system can be adjusted via a stepless adjustment. Once fully installed, the trunking covers can be opened at any time. This means that it is no problem at all to install cables or lines at a later date. It is also possible to fit installation units or pedestal boxes through the installation openings in the trunking covers. When using trunking junction boxes, this system offers the advantage that smaller trunking cross-sections can be chosen as the entire interior of the trunking is available for lines to be inserted. Screed-flush trunking is available for dry and wet-cleaned floors with a flexible foil casing or with a sheet metal bottom. Factory-fitted footfall sound insulation and

the freedom to use any preferred floor covering means that this system also meets the highest requirements in terms of flexibility. This height-adjustable system is perfect for all applications in which the final installation details are not yet clear or in which the highest possible degree of flexibility is to be retained. Thanks to their width of up to 600 mm, these trunkings are used where a high number of lines is required. This screed-flush trunking is used in production halls with bare floors as well as in office and administration buildings where the floor coverings are glued onto the trunking covers. Due to its low height, the trunking system can be installed in screeds with very low profiles starting from 40 mm.

BKF trunking with foil casing for dry-cleaned floors

Properties: - Suitable for dry-cleaned floors - Easy and flexible installation -F  lexibility to other areas of installation, e.g. transverse heating pipes or ducts - Entire internal space is available to hold lines

BKF trunking with trunking bottom for dry-cleaned floors

Properties: - Suitable for dry-cleaned floors - Easy access to the lines - Clean installation is possible, lines are protected against dust and dirt

90

Technical changes reserved

electraplan.BK Flush-floor trunking system

tehalit.BKB

BKFD trunking with foil casing and sealing option

Properties: - Suitable for wet-cleaned floors - Easy and flexible installation -F  lexibility to other areas of installation, e.g. transverse heating pipes or ducts - Entire internal space is available to hold lines

BKWD trunking with trunking bottom and sealing option

Properties: - Suitable for wet-cleaned floors - Easy access to the lines -C  lean installation is possible, lines are protected against dust and dirt

Technical changes reserved

91

electraplan.BK Shaped parts – ready to go!

tehalit.BKB

Available on request. Ready-assembled shaped parts are available on request. They can be assembled with the standard trunking on-site following the building-block principle. The different sizes can be fed off from the standard trunking. Shaped parts are supplied with factory-fitted levelling clamps. Footfall sound insulation and set screws are included in the accessories package.

92

Technical changes reserved

electraplan.BK Line volume with foil casing Determining the line volume

This is why the formula (d)², i.e. the diameter squared, must be applied. To ensure sufficient space for possible later retrofitting, trunking ducts should only be filled to 50% of their volume. This also makes it easier to pull the lines into the trunking. Also, it must be noted that the calculation does not take into account bottom troughs and outlets that possibly interrupt the line path.

safety fa

ctor

Order number

Height max. mm 70

Usable cross-section cm² 5 77 154

BKF150045 BKF150065 BKF150105 BKF150145 BKF200045 BKF200065 BKF200105 BKF200145 BKF250045 BKF250065 BKF250105 BKF250145 BKF300045 BKF300065 BKF300105 BKF300145 BKF350045 BKF350065 BKF350105 BKF350145 BKF400045 BKF400065 BKF400105 BKF400145 BKF500045 BKF500065 BKF500105 BKF500145 BKF600045 BKF600065 BKF600105 BKF600145

6 106

7 78

8 60

9 47

10 38

11 31

12 26

13 22

14 19

15 17

16 15

17 13

18 11

19 10

20 9

110 150 190 70 110 150 190 70 110 150 190 70 110 150 190 70 110 150 190 70 110 150 190 70 110 150 190 70 110 150 190

121 165 209 112 176 240 304 147 231 315 399 182 286 390 494 217 341 465 589 252 396 540 684 322 506 690 874 392 616 840 1064

168 229 290 155 244 333 422 204 320 437 554 252 397 541 686 301 473 645 818 350 550 750 950 447 702 958 1213 544 855 1166 1477

123 168 213 114 179 244 310 150 235 321 407 185 291 397 504 221 347 474 601 257 404 551 697 328 516 704 891 400 628 857 1085

94 128 163 87 137 187 237 114 180 246 311 142 223 304 385 169 266 363 460 196 309 421 534 251 395 539 682 306 481 656 831

74 101 129 69 108 148 187 90 142 194 246 112 176 240 304 133 210 287 363 155 244 333 422 198 312 425 539 241 380 518 656

60 82 104 56 88 120 152 73 115 157 199 91 143 195 247 108 170 232 294 126 198 270 342 161 253 345 437 196 308 420 532

50 68 86 46 72 99 125 60 95 130 164 75 118 161 204 89 140 192 243 104 163 223 282 133 209 285 361 161 254 347 439

42 57 72 38 61 83 105 51 80 109 138 63 99 135 171 75 118 161 204 87 137 187 237 111 175 239 303 136 213 291 369

35 48 61 33 52 71 89 43 68 93 118 53 84 115 146 64 100 137 174 74 117 159 202 95 149 204 258 115 182 248 314

30 42 53 28 44 61 77 37 58 80 101 46 72 99 126 55 86 118 150 64 101 137 174 82 129 176 222 100 157 214 271

26 36 46 24 39 53 67 32 51 70 88 40 63 86 109 48 75 103 130 56 88 120 152 71 112 153 194 87 136 186 236

23 32 40 21 34 46 59 28 45 61 77 35 55 76 96 42 66 90 115 49 77 105 133 62 98 134 170 76 120 164 207

20 28 36 19 30 41 52 25 39 54 69 31 49 67 85 37 58 80 101 43 68 93 118 55 87 119 151 67 106 145 184

18 25 32 17 27 37 46 22 35 48 61 28 44 60 76 33 52 71 90 38 61 83 105 49 78 106 134 60 95 129 164

16 22 28 15 24 33 42 20 31 43 55 25 39 54 68 30 47 64 81 34 54 74 94 44 70 95 121 54 85 116 147

15 20 26 14 22 30 38 18 28 39 49 22 35 48 61 27 42 58 73 31 49 67 85 40 63 86 109 49 77 105 133

242 330 418 224 352 480 608 294 462 630 798 364 572 780 988 434 682 930 1178 504 792 1080 1368 644 1012 1380 1748 784 1232 1680 2128

Line diameter in mm

Technical changes reserved

93

tehalit.BKB

The line volume must be known in order to define the correct trunking size. In practice, lines never run perfectly in parallel and side-by-side in a way that would ensure maximum space utilisation. This is why the formula (d)², i.e. the diameter squared, must be applied.

tehalit.BKB

electraplan.BK Line volume with trunking bottom

safety fac

tor

Order number

BKW150040

Height Usable max. cross-secmm tion cm² 5 28 37.5 75

6 52

7 38

8 29

9 23

10 18

11 15

12 13

13 11

14 9

15 8

16 7

17 6

18 5

19 5

20 4

BKW150050 BKW150060 BKW150070 BKW200060 BKW200070 BKW200080 BKW200090 BKW250060 BKW250070 BKW250080 BKW250090 BKW300060 BKW300070 BKW300080 BKW300090 BKW350060 BKW350070 BKW350080 BKW350090 BKW400060 BKW400070 BKW400080 BKW400090 BKW500060 BKW500070 BKW500080 BKW500090 BKW600060 BKW600070 BKW600080 BKW600090

38 48 58 48 58 68 78 48 58 68 78 48 58 68 78 48 58 68 78 48 58 68 78 48 58 68 78 48 58 68 78

70 89 107 122 148 173 199 156 188 221 253 189 228 268 307 222 269 315 361 256 309 362 416 322 389 457 524 389 470 551 632

51 65 79 90 108 127 146 114 138 162 186 139 168 197 226 163 197 231 265 188 227 266 305 237 286 335 385 286 345 405 464

39 50 60 69 83 97 112 87 106 124 142 106 128 150 173 125 151 177 203 144 174 204 234 181 219 257 294 219 264 310 355

31 39 47 54 65 77 88 69 83 98 112 84 101 119 136 98 119 140 160 113 137 161 184 143 173 203 233 173 209 245 281

25 32 38 44 53 62 71 56 67 79 91 68 82 96 110 80 96 113 130 92 111 130 149 116 140 164 188 140 169 198 227

21 26 32 36 44 51 59 46 56 65 75 56 68 79 91 66 80 93 107 76 92 107 123 96 116 136 156 115 139 164 188

17 22 26 30 37 43 49 39 47 55 63 47 57 67 76 55 67 78 90 64 77 90 104 80 97 114 131 97 117 137 158

15 19 22 26 31 37 42 33 40 47 54 40 48 57 65 47 57 67 77 54 65 77 88 68 83 97 111 82 100 117 134

12 16 19 22 27 31 36 28 34 40 46 34 42 49 56 40 49 57 66 47 56 66 76 59 71 83 96 71 86 101 116

11 14 17 19 23 27 31 24 30 35 40 30 36 42 49 35 43 50 57 40 49 58 66 51 62 73 83 62 75 88 101

9 12 15 17 20 24 28 21 26 31 35 26 32 37 43 31 37 44 50 36 43 51 58 45 54 64 73 54 66 77 88

8 11 13 15 18 21 24 19 23 27 31 23 28 33 38 27 33 39 45 31 38 45 51 40 48 56 65 48 58 68 78

7 9 11 13 16 19 22 17 20 24 28 21 25 29 34 24 29 35 40 28 34 40 46 35 43 50 58 43 52 61 70

7 8 10 12 14 17 19 15 18 22 25 18 22 26 30 22 26 31 36 25 30 36 41 32 38 45 52 38 46 55 63

6 8 9 11 13 15 17 14 16 19 22 17 20 24 27 20 24 28 32 23 27 32 37 29 35 41 47 35 42 49 56

94

50.9 64.3 77.7 88.3 106.7 125.1 143.5 112.3 135.7 159.1 182.5 136.3 164.7 193.1 221.5 160.3 193.7 227.1 260.5 184.3 222.7 261.1 299.5 232.3 280.7 329.1 377.5 280.3 338.7 397.1 455.5

101 128 155 176 213 250 287 224 271 318 365 272 329 386 443 320 387 454 521 368 445 522 599 464 561 658 755 560 677 794 911

Line diameter in mm

Technical changes reserved

electraplan.BK Installation instructions, Flush-floor trunking system General instructions: DIN standard System components must be included in the earthing measures in accordance with DIN VDE 0100. tehalit.BKB

Support If trunking bottoms are used, they must be supported from below to prevent deformation. Sealing Gaps must be sealed against screed ingress. The flexible screed casing must not have any contact with hot screed. Protection Protective measures must be coordinated with the screed layer. No load Do not remove the cross members and do not impose any mechanical loads or walk on the trunking system before the screed has hardened. Protective covers Protective covers of service outlets must not be removed until right before flooring installation. Further instructions Ensure that the installation instructions for the screed layers and the flooring fitters are observed and that they are passed on to the contractors responsible before laying the flooring.

Technical changes reserved

95

electraplan.BK Installation instructions, Flush-floor trunking system Assemble the levelling sets

Position the levelling sets

Mark the trunking routing on the slab according to the installation plan using chalk or string. Check the actual levelling heights on the slab.

Install the M8 set screws into the levelling clamps. Place brackets with insulating mounts on a level and firm surface and push in the set screws.

The levelling clamps should be spaced at 800 mm along the trunking lateral profile. Roughly adjust the levelling height.

Adjust the screed casing

Join the trunking sections

Secure the trunking sections

The screed casing must be outside the trunking, extending from the trunking lateral profile downward and vertically outward onto the slab. The retaining tabs rest on the horizontal part of the casing, pressing it onto the slab.

At the joints of the trunking sections, push the pre-assembled cross members halfway under the cover of the subsequent trunking section. At this section, slacken the cover screw and butt-join the sections.

Connect the sections using trunking connector, levelling clamp and M5 bolts. Tighten the cover screws. The flexible screed casing must overlap at the section joint.

Snap in the screed anchor

Level the trunking

Secure the retaining tabs

Snap the screed anchor into the profile groove to stabilise the trunking lateral profiles. The spacing along the lateral profiles must not exceed 800 mm.

Adjust the top edge of the trunking lateral profile to the required height.

Plug the retaining tabs to the slab.

tehalit.BKB

Mark the trunking routing

96

Technical changes reserved

electraplan.BK Installation instructions, Flush-floor trunking system Seal the joints

Screed expansion

If using trunking bottoms, use underlays. Ensure that the screed installer is explicitly informed of this measure. If cross members with levelling support are used, the trunking bottom must be perforated on site so that the set screw firmly sits on the slab!

Carefully seal the joints of the trunking system against screed ingress.

Screed may expand while hardening, causing it to push against the trunking. The pressure is determined by the size of the screed slab and its composition. Sponge rubber strips may be attached to the profile to reduce pressure. Please consult the screed layer.

Position the cross members

Cross members with threaded sleeve

Shorten set screws

Each cover butt joint must be supported by a cross member. From trunking nominal widths greater than 300 mm, covers must be additionally supported between the joints. The cross members must be equally spaced.

Install the set screw in the threaded sleeve. Install lock nut BKZKM80 and insulating mount BKZNSD0 to the set screw. Slightly tension the cross member against the slab using the set screw. Secure the set screw using lock nut BKZKM80 below the levelling sleeve.

If required, trim the set screws so that they are flush with the top edge of the cross member.

Trunking partition wall BKTWK

Trunking partition wall BKTWS

Earthing measure for trunking BKF

Plug the feet of trunking partition wall BKTWK at a spacing of 500 mm to the slab. Push the partition wall into the feet.

Plug partition wall BKTWS directly to the slab. Bores in the separating walls must be created on site. Connect the separating wall to ground using the tap-on grounding clamps provided.

During installation of trunking, push connector from the side into inner profile slot. Remove blank cover from trunking and tighten the screw at the connector. Connect the earth conductor cable to the earthing measure using an end sleeve (available as option).

tehalit.BKB

Support the trunking bottom

Technical changes reserved

97

electraplan.BK Installation instructions, Flush-floor trunking system Blank cover with cover snap fastener

Lay the screed

During installation of trunkings, push the connector clamps (available as option) from the side into the inner profile slot. Remove blank cover from trunking and tighten bolt M3 at the connector clamp. Connect the earth conductor cable connector clamp to the earthing measure.

The earth conductor cable (available as option) is welded to the blank cover with cover snap at the factory. After installation, remove the blank covers from the trunking and secure the earth conductor cable of the blank cover to the profile using the eyelet.

Install the screed up to the top edge of the trunking profiles. Blank covers can be fitted with flooring using adhesive.

tehalit.BKB

Earthing measures for trunking BKFD

Install installation units

Installation units such as Service units or floor-mounting pedestal boxes can be installed in the trunking. This requires replacing the blank cover by an installation cover with a corresponding opening.

98

Technical changes reserved

electraplan.BK Installation instructions, Flush-floor trunking system BKFD with sealing option General instructions: Seal The seal is made of compressed cellular rubber with wax-plastic water-proofing. tehalit.BKB

Properties After unrolling, the material takes some time to expand, thereby pressing itself between trunking cover and lateral profile. Storage The sealing tape may only be processed at room temperatures between 15 °C and 25 °C. Before installation, the sealing tape must have been stored at room temperature for at least 24 hours.

Technical changes reserved

99

electraplan.BK Installation instructions, Flush-floor trunking system BKFD with sealing option Cut off sealing tape

Attach adhesive sealing tape

Before installing the sealing tape, open the trunking system and clean it on the inside and outside. The slot holding the sealing tape must be free of dust and grease. Do not open the trunking system before the screed has fully hardened.

Cut off the required length.

Peel off the backing paper over a length of approx. 20 - 30 cm. Place the sealing tape into the slot in the lateral profile and press it in lightly.

Sealing tape joints

Sealing corners

Cross members

At the joints, the sealing tape ends must join exactly and with slight pressure. Do not cut them at an angle and do not let them overlap.

Never bend the sealing tape around a corner without cutting it. As with the joints, join the ends with slight pressure.

Install two sealing strips in the centre of the cross member. Install their ends as with the 90° corner. Install sealing tape only at the cross members supporting cover joints.

tehalit.BKB

Preparation

100

Technical changes reserved

electraplan.BK Installation instructions, Flush-floor trunking connection socket General instructions:

tehalit.BKB

Lateral attachment Connection socket BKSA can be installed to the side of trunking BKF / BKFD to allow installation of flush-floor or pedestal installation units via an installation opening. Larger cross-section Sockets eliminate the reduction of the cross-section in the trunking immanent with direct installation of installation units in the trunking. Accessories Installation requires one levelling clamp of the existing trunking and one levelling set BKSAN.

Cut out the screed casing

Prepare the levelling set

Cut out the screed casing on the side so that the connection socket can be attached.

Install nut BKZKM80 and insulating mount BKZNSD0 to the set screw. Install set screw into support bracket.

Technical changes reserved

101

electraplan.BK Installation instructions, Flush-floor trunking connection socket Install the levelling set

Slide the levelling set into position

Secure the support bracket to the trunking lateral profile using a trunking connector. Tighten the set screws against the slab. Secure the set screw by tightening lock nut BKZKM80 from below against the threaded sleeve. If required, cut off the set screw so that it is flush with the top edge of the support bracket.

Insert the trunking connector into the outer slot of the lateral profile. Install set screw BKZNS into the levelling clamp. Install the retaining tab with insulating mount BKZHP00.

Disconnect the existing levelling clamp at the trunking from the connector. Slide both parts to the installation position of the socket to be installed.

Install the levelling set

Attach the connecting socket

Plug the retaining tabs

Engage the trunking connector in the outer slot of the connecting socket. Screw the levelling clamp to the slot of the connecting socket using a trunking connector. Install the set screw BKZNS into the levelling clamp. Install the retaining tab with insulating mount BKZHP00.

Connect the connecting socket to the trunking lateral profile. Install the angled connection, tighten the screws. The screed casing must be on the outside.

Plug the retaining tabs to the slab.

Engage the screed anchor

Lay the screed

Insert the service unit

Engage the screed anchor into the profile of the connecting socket.

Once the screed is installed, the adhesive protective cover can be removed.

Insert the service unit into the opening and secure it. Due to the connection socket, the entire cross-section of the main trunking is maintained.

tehalit.BKB

Attach the levelling set

102

Technical changes reserved

electraplan.BK Installation instructions, 90° angle branch made by customer

Please order the following additional parts: 1 x connection set BKZVS90 1 x end piece BKFV

Shorten trunking section A on one side by the width dimension (trunking - 20 mm). Attach end piece (1) with levelling clamp and trunking connector (2) to trunking section B. Attach trunking section A and end piece at the outer corner of the angled connectors (3).

Join the trunking sections at the inner corner using the angled connector (4) and secure them. Attach the cross member (5) to the trunking lateral profile of trunking section B. The cross member must support the covers of trunking sections A

and B. Cross members installed in trunking sections wider than 350 mm must be fitted with the levelling support. Locate the levelling brackets at an even spacing of max. 800 mm and secure them to the trunking using connectors.

90° angle branch made by the customer for installation heights greater than 40 mm Please order the following additional parts: 1 x connection set BKZVS90 1 x end piece BKFV

Cut out the screed casing at the branch-out. Attach the angled piece (4b) to the angle connector (3b) and attach the end piece (1) to trunking end A using the M5 bolt. Connect trunking section A and B using the angled connector (4a, 4b).

Attach the cross member (5) to the trunking lateral profile of trunking section (B). The cross member must support the cover joint of trunking section B. Cross members installed in trunking sections wider than 350 mm must be fitted with the levelling support.

Locate the levelling brackets at an even spacing of max. 800 mm and secure them to the trunking using connecting pieces.

As an alternative, the shaped parts can be ordered as pre-assembled units!

Technical changes reserved

103

tehalit.BKB

90° angle branch made by customer

electraplan.BK Installation instructions, T-branch made by the customer T-branch made by the customer

tehalit.BKB

Please order the following additional parts: 1 x connection set BKZVS90

Create a cut-out on one side of the trunking section A that fits the width of the branched-out trunking section B. Insert the branched-out trunking section B into the cut-out. Join both trunking sections using an angled connector (4).

Attach the cross member (5) to the trunking lateral profile of trunking section B. The cross member must support the covers of trunking sections A and B. Cross members installed in trunking sections wider than 350 mm must be fitted with the levelling support.

Locate the levelling brackets at an even spacing of max. 800 mm and secure them to the trunking using connectors.

T-branch made by the customer for installation heights greater than 40 mm

104

Technical changes reserved

electraplan.BK Installation instructions, T-branch made by the customer T-branch made by the customer for installation heights greater than 40 mm

tehalit.BKB

Please order the following additional parts: 1 x connection set BKZVS90

Locate branched-out trunking section B at section A and connect them using an angled connector (4). Attach the cross member (5) to the trunking lateral profile of trunking section B. The cross member must support the cover

joint of trunking section B. Cross members installed in trunking sections wider than 350 mm must be fitted with the levelling support. Locate the levelling brackets at an even spacing of max. 800 mm and secure them to the trunking

using connecting pieces. Recommendation: Firmly bolt a short piece of blank cover (6) to trunking section B. If no blank cover (6) is used, then the flooring may not adhere reliably to the lateral profile of trunking section A in the area of the branch-out.

As an alternative, the shaped parts can be ordered as pre-assembled units!

Technical changes reserved

105

On-the-floor trunking system

electraplan.AK On-the-floor trunking

electraplan.AK | On-the-floor trunking The robust retrofit solution electraplan.AK on-the-floor trunking for retrospective installation on finished floors is the ideal solution for renovation, redevelopment and modernisation. The preassembled moulded parts enable quick and simple modular assembly on the construction site and, because electraplan.AK allows the position of the individual covers with their insert openings to be changed as and when required, it is also extremely flexible with regard to future changes. Further advantage:The three-millimetre thick blank covers, made of galvanised sheet steel in accordance with DIN EN 10327, make the system extremely stable and also enable it to withstand high loads.In addition, a large number of other on-the-floor trunking parts made of plastic and aluminium are available in cases where it is possible to safely run smaller numbers of lines.

System overview

108

Trunking overview

109

On the floor trunking system single sided, height 40 mm

110

On the floor trunking system single sided, height 70 mm

112

On the floor trunking system double sided, height 40 mm

114

On the floor trunking system double sided, height 70 mm

116

Covers with installation opening

118

Accessories

120

On-the-floor trunking, Aluminium On-the-floor trunking, PVC

122

Order number composition

124

Technical Information

125

electraplan.AK On-the-floor trunking

electraplan.AK

107

electraplan.AK System overview 3

2 “ ß

electraplan.AK On-the-floor trunking

0 5

1

4 9

7

8

6

electraplan.AK 1 Lower part, single-sided 2 Blank cover, single-sided 3 Inner corner, single-sided 4  Outer corner, single-sided 5 End piece, single-sided 6 Lower part, double-sided 7 Blank cover, double-sided 8 End cap, double-sided 9 Blank cover 45° junction 0 Connection ß Cover with installation opening GBZ “ Cover with installation opening R10

108

Technical changes reserved

electraplan.AK Trunking overview Trunking width mm

Trunking height mm

Type

single sided single sided single sided single sided

Usable cross-section cm² 60 80 100 120

Max. line configuration Ø 11 mm Filling factor 0.5 24 33 41 49

AKU1500401 AKU2000401 AKU2500401 AKU3000401

150 200 250 300

40 40 40 40

AKU1500701 AKU2000701 AKU2500701 AKU3000701 AKU3500701 AKU4000701

150 200 250 300 350 400

70 70 70 70 70 70

single sided single sided single sided single sided single sided single sided

105 140 175 210 245 280

43 57 72 86 101 115

107 107 107 107 107 107

AKU1500402 AKU2000402 AKU2500402 AKU3000402

150 200 250 300

40 40 40 40

double sided double sided double sided double sided

60 80 100 120

24 33 41 49

107 107 107 107

AKU1500702 AKU2000702 AKU2500702 AKU3000702 AKU3500702 AKU4000702

150 200 250 300 350 400

70 70 70 70 70 70

double sided double sided double sided double sided double sided double sided

105 140 175 210 245 280

43 57 72 86 101 115

107 107 107 107 107 107

Technical changes reserved

Page

107 107 107 107

109

electraplan.AK On-the-floor trunking

Trunking lower part

electraplan.AK Floor mounted trunking system, single-sided, height 40 mm

electraplan.AK On-the-floor trunking

- Trunking for laying on the existing floor in dry rooms with dry-cleaned floors - For guiding electrical lines - For fitting with installation units protruding above the floor - Lower part, height 40 mm - Side profile: Extruded aluminium profile, 1 x 2400 mm, 6 x 100 mm long - Delivery time approx. 5 working days.

- With rigidly inserted steel sheet partition walls on request Form of delivery Order lower part, blank cover, separately Supplied lengths Lower part: 2400 mm Blank cover: 400 / 800 mm

Lower part

Trunking height

Steel sheet

[mm]

AKU1500401

AKU1500401 PU 24 m

40

AKU2000401

AKU2000401 PU 24 m

40

AKU2500401

AKU2500401 PU 24 m

40

AKU3000401

AKU3000401 PU 24 m

40

110

Technical changes reserved

Material Lower part: 1 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1 Blank cover: 3 mm galvanised steel sheet,Galvanised in accordance with DIN NF EN 10327-1

Blank cover Length 800 mm Steel sheet

Blank cover Length 400 mm Steel sheet

Inner corner

Outer corner

End piece

Steel sheet

Steel sheet

Steel sheet

Connection Length 800 mm Steel sheet

AKB81500401 PU 1 pc

AKB41500401 PU 1 pc

AKBI1500401 PU 1 pc

AKBA1500401 PU 1 pc

AKE1500401 PU 1 pc

AKBAS1500401 PU 1 pc

AKB82000401 PU 1 pc

AKB42000401 PU 1 pc

AKBI2000401 PU 1 pc

AKBA2000401 PU 1 pc

AKE2000401 PU 1 pc

AKBAS2000401 PU 1 pc

AKB82500401 PU 1 pc

AKB42500401 PU 1 pc

AKBI2500401 PU 1 pc

AKBA2500401 PU 1 pc

AKE2500401 PU 1 pc

AKBAS2500401 PU 1 pc

AKB83000401 PU 1 pc

AKB43000401 PU 1 pc

AKBI3000401 PU 1 pc

AKBA3000401 PU 1 pc

AKE3000401 PU 1 pc

AKBAS3000401 PU 1 pc

Technical changes reserved

electraplan.AK On-the-floor trunking

Note - Screws, dowels and other materials for installing the on-the-floor trunking system are not included in the scope of delivery. - Holes are not countersunk - Countersinking of attachment holes for individual configurations with flooring, available on request

111

electraplan.AK Floor mounted trunking system, single-sided, height 70 mm

electraplan.AK On-the-floor trunking

- Trunking for laying on the existing floor in dry rooms with dry-cleaned floors - For guiding electrical lines - For fitting with floor-level units or units protruding above the floor - Lower part, height 70 mm - Side profile: Extruded aluminium profile, 1 x 2400 mm, 6 x 100 mm long

- Delivery time approx. 5 working days.- With rigidly inserted steel sheet partition walls on request Form of delivery Lower part, Blank cover separat bestellen Supplied lengths Lower part: 2400 mm

Lower part

Trunking height

Steel sheet

[mm]

AKU1500701

AKU1500701 PU 24 m

70

AKU2000701

AKU2000701 PU 24 m

70

AKU2500701

AKU2500701 PU 24 m

70

AKU3000701

AKU3000701 PU 24 m

70

AKU3500701

AKU3500701 PU 24 m

70 40

AKU4000701

112

AKU4000701 PU 24 m

70

Technical changes reserved

Blank cover: 400 / 800 mm Material Lower part: 1 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1 Blank cover: 3 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1

Blank cover Length 800 mm Steel sheet

Blank cover Length 400 mm Steel sheet

Inner corner

Outer corner

End piece

Steel sheet

Steel sheet

Steel sheet

Connection Length 800 mm Steel sheet

AKB81500701 PU 1 pc

AKB41500701 PU 1 pc

AKBI1500701 PU 1 pc

AKBA1500701 PU 1 pc

AKE1500701 PU 1 pc

AKBAS1500701 PU 1 pc

AKB82000701 PU 1 pc

AKB42000701 PU 1 pc

AKBI2000701 PU 1 pc

AKBA2000701 PU 1 pc

AKE2000701 PU 1 pc

AKBAS2000701 PU 1 pc

AKB82500701 PU 1 pc

AKB42500701 PU 1 pc

AKBI2500701 PU 1 pc

AKBA2500701 PU 1 pc

AKE2500701 PU 1 pc

AKBAS2500701 PU 1 pc

AKB83000701 PU 1 pc

AKB43000701 PU 1 pc

AKBI3000701 PU 1 pc

AKBA3000701 PU 1 pc

AKE3000701 PU 1 pc

AKBAS3000701 PU 1 pc

AKB83500701 PU 1 pc

AKB43500701 PU 1 pc

AKBI3500701 PU 1 pc

AKBA3500701 PU 1 pc

AKE3500701 PU 1 pc

AKBAS3500701 PU 1 pc

AKB84000701 PU 1 pc

AKB44000701 PU 1 pc

AKBI4000701 PU 1 pc

AKBA4000701 PU 1 pc

AKE4000701 PU 1 pc

AKBAS4000701 PU 1 pc

Technical changes reserved

electraplan.AK On-the-floor trunking

Note - Screws, dowels and other materials for installing the on-the-floor trunking system are not included in the scope of delivery. - Holes are not countersunk. - Countersinking of attachment holes for individual configurations with flooring, available on request

113

electraplan.AK Floor mounted trunking system, double-sided, height 40 mm

electraplan.AK On-the-floor trunking

- Trunking for laying on the existing floor in dry rooms with dry-cleaned floors - For guiding electrical lines - For fitting with installation units protruding above the floor - Lower part, height 40 mm - Side profile: Extruded aluminium profile, 12 x 100 mm long- Delivery time approx. 5 working days.

- With rigidly inserted steel sheet partition walls on request Form of delivery Order lower part, blank cover, separately Supplied lengths Lower part: 2400 mm Blank cover: 400 / 800 mm

Lower part

Trunking height

Steel sheet

[mm]

AKU1500402

AKU1500402 PU 24 m

40

AKU2000402

AKU2000402 PU 24 m

40

AKU2500402

AKU2500402 PU 24 m

40

AKU3000402

AKU3000402 PU 24 m

40

114

Technical changes reserved

Material Lower part: 1 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1 Blank cover: 3 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1

Blank cover Length 800 mm Steel sheet

Blank cover Length 400 mm Steel sheet

Blank cover 800 mm extended 100 Steel sheet

Blank cover 400 mm -extended 100 Steel sheet

Inner corner Extended 100 mm Steel sheet

Outer corner Extended 100 mm Steel sheet

End piece Steel sheet

45°Abzweig Length 800 mm Steel sheet

AKB81500402 PU 1 pc

AKB41500402 PU 1 pc

AKB81500401V PU 1 pc

AKB41500401V PU 1 pc

AKBI1500401V PU 1 pc

AKBA1500401V PU 1 pc

AKE1500402 PU 1 pc

AKBAZ1500402 PU 1 pc

AKB82000402 PU 1 pc

AKB42000402 PU 1 pc

AKB82000401V PU 1 pc

AKB42000401V PU 1 pc

AKBI2000401V PU 1 pc

AKBA2000401V PU 1 pc

AKE2000402 PU 1 pc

AKBAZ2000402 PU 1 pc

AKB82500402 PU 1 pc

AKB42500402 PU 1 pc

AKB82500401V PU 1 pc

AKB42500401V PU 1 pc

AKBI2500401V PU 1 pc

AKBA2500401V PU 1 pc

AKE2500402 PU 1 pc

AKBAZ2500402 PU 1 pc

AKB83000402 PU 1 pc

AKB43000402 PU 1 pc

AKB83000401V PU 1 pc

AKB43000401V PU 1 pc

AKBI3000401V PU 1 pc

AKBA3000401V PU 1 pc

AKE3000402 PU 1 pc

AKBAZ3000402 PU 1 pc

Technical changes reserved

115

electraplan.AK On-the-floor trunking

Note - Screws, dowels and other materials for installing the on-the-floor trunking system are not included in the scope of delivery. - Holes are not countersunk. - Countersinking of attachment holes for individual configurations with flooring, available on request - The term upper part extended 100 mm means 100 mm width overhang. The cover is used, for example, for heating pipes laid in the floor area.

electraplan.AK Floor mounted trunking system, double-sided, height 70 mm

electraplan.AK On-the-floor trunking

- Trunking for laying on the existing floor in dry rooms with dry-cleaned floors - For guiding electrical lines - For fitting with floor-level units or units protruding above the floor - Lower part, height 70 mm - Side profile: Extruded aluminium profile, 12 x 100 mm long - Delivery time approx. 5 working days.

- With rigidly inserted steel sheet partition walls on request Form of delivery Order lower part, blank cover, separately Supplied lengths Lower part: 2400 mm Blank cover: 400 / 800 mm

Lower part

Trunking height

Steel sheet

[mm]

AKU1500702

AKU1500702 PU 24 m

70

AKU2000702

AKU2000702 PU 24 m

70

AKU2500702

AKU2500702 PU 24 m

70

AKU3000702

AKU3000702 PU 24 m

70

AKU3500702

AKU3500702 PU 24 m

70

AKU4000702

AKU4000702 PU 24 m

70

116

Technical changes reserved

Material Lower part: 1 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1 Blank cover: 3 mm galvanised steel sheet, Galvanised in accordance with DIN NF EN 10327-1

Blank cover Length 800 mm Steel sheet

Blank cover Length 400 mm Steel sheet

Blank cover 800 mm extended 100 Steel sheet

Blank cover 400 mm extended 100 Steel sheet

Inner corner Extended 100 mm Steel sheet

Outer corner Extended 100 mm Steel sheet

End piece Steel sheet

45°Abzweig Length 800 mm Steel sheet

AKB81500702 PU 1 pc

AKB41500702 PU 1 pc

AKB81500701V PU 1 pc

AKB41500701V PU 1 pc

AKBI1500701V PU 1 pc

AKBA1500701V PU 1 pc

AKE1500702 PU 1 pc

AKBAZ1500702 PU 1 pc

AKB82000702 PU 1 pc

AKB42000702 PU 1 pc

AKB82000701V PU 1 pc

AKB42000701V PU 1 pc

AKBI2000701V PU 1 pc

AKBA2000701V PU 1 pc

AKE2000702 PU 1 pc

AKBAZ2000702 PU 1 pc

AKB82500702 PU 1 pc

AKB42500702 PU 1 pc

AKB82500701V PU 1 pc

AKB42500701V PU 1 pc

AKBI2500701V PU 1 pc

AKBA2500701V PU 1 pc

AKE2500702 PU 1 pc

AKBAZ2500702 PU 1 pc

AKB83000702 PU 1 pc

AKB43000702 PU 1 pc

AKB83000701V PU 1 pc

AKB43000701V PU 1 pc

AKBI3000701V PU 1 pc

AKBA3000701V PU 1 pc

AKE3000702 PU 1 pc

AKBAZ3000702 PU 1 pc

AKB83500702 PU 1 pc

AKB43500702 PU 1 pc

AKB83500701V PU 1 pc

AKB43500701V PU 1 pc

AKBI3500701V PU 1 pc

AKBA3500701V PU 1 pc

AKE3500702 PU 1 pc

AKBAZ3500702 PU 1 pc

AKB84000702 PU 1 pc

AKB44000702 PU 1 pc

AKB84000701V PU 1 pc

AKB44000701V PU 1 pc

AKBA4000701V PU 1 pc

AKE4000702 PU 1 pc

AKBAZ4000702 PU 1 pc

AKBI4000701V PU 1 pc

Technical changes reserved

117

electraplan.AK On-the-floor trunking

Note - Screws, dowels and other materials for installing the on-the-floor trunking system are not included in the scope of delivery. - Holes are not countersunk. - Countersinking of attachment holes for individual configurations with flooring, available on request - The term upper part extended 100 mm means 100 mm width overhang. The cover is used, for example, for heating pipes laid in the floor area.

electraplan.AK Covers with installation opening - Covers with installation opening for one-sided trunking, height 70 mm - Installation openings for units flush to the floor and protruding above the floor, as factory-fitted blanking in the blank cover - The opening is sealed with a protection cover - Other versions on request

Note - The length of the cover with installation opening is 400 mm - If required, order 400 mm length blank covers separately

electraplan.AK On-the-floor trunking

Covers with installation opening GBZ Properties: - Round, diameter 50 mm

AKM150050GBZ

Designation

PU

Cover GBZ round 50 L=400mm AK 150x70 Cover GBZ round 50 L=400mm AK 200x70 Cover GBZ round 50 L=400mm AK 250x70 Cover GBZ round 50 L=400mm AK 300x70 Cover GBZ round 50 L=400mm AK 350x70 Cover GBZ round 50 L=400mm AK 400x70

1 1 1 1 1 1

Order no.

AKM150050GBZ AKM200050GBZ AKM250050GBZ AKM300050GBZ AKM350050GBZ AKM400050GBZ

Cover with installation opening R06 Properties: - Round, diameter 215 mm

AKM300215R06

Designation

PU

Cover R06 round 215 L=400mm AK 300x70 Cover R06 round 215 L=400mm AK 350x70 Cover R06 round 215 L=400mm AK 400x70

1 1 1

Order no.

AKM300215R06 AKM350215R06 AKM400215R06

Cover with installation opening R10 Properties: - Round, diameter 275 mm

AKM350275R10

Designation

PU

Cover R10 round 275 L=400mm AK 350x70 Cover R10 round 275 L=400mm AK 400x70

1 1

Order no.

AKM350275R10 AKM400275R10

Cover with installation opening R12 Properties: - Round, diameter 306 mm

AKM350306R12

118

Designation

PU

Cover R12 round 306 L=400mm AK 350x70 Cover R12 round 306 L=400mm AK 400x70

1 1

Technical changes reserved

Order no.

AKM350306R12 AKM400306R12

electraplan.AK Covers with installation opening Cover with installation opening Q06 Properties: - Square, edge length 200 mm PU

Cover Q06 200x200 L=400mm AK 250x70 Cover Q06 200x200 L=400mm AK 300x70 Cover Q06 200x200 L=400mm AK 350x70 Cover Q06 200x200 L=400mm AK 400x70

1 1 1 1

Order no.

AKM250200Q06 AKM300200Q06 AKM350200Q06 AKM400200Q06

Cover with installation opening Q12 Properties: - Square, edge length 244 mm

AKM300244Q12

Designation

PU

Cover Q12 244x244 L=400mm AK 300x70 Cover Q12 244x244 L=400mm AK 350x70 Cover Q12 244x244 L=400mm AK 400x70

1 1 1

Order no.

AKM300244Q12 AKM350244Q12 AKM400244Q12

Cover with installation opening E04 Properties: - Cornered 147 x 247 mm

AKM200147E04

Designation

PU

Cover E04 147x247 L=400mm AK 200x70 Cover E04 147x247 L=400mm AK 250x70 Cover E04 147x247 L=400mm AK 300x70 Cover E04 147x247 L=400mm AK 350x70 Cover E04 147x247 L=400mm AK 400x70

1 1 1 1 1

Order no.

AKM200147E04 AKM250147E04 AKM300147E04 AKM350147E04 AKM400147E04

Cover with installation opening Q08 Properties: - Square, edge length 294 mm

AKM350294Q08

Designation

PU

Cover Q08 294x294 L=400mm AK 350x70 Cover Q08 294x294 L=400mm AK 400x70

1 1

Order no.

AKM350294Q08 AKM400294Q08

Cover with installation opening E09 Properties: - Cornered 200 x 253 mm

AKM250200E09

Designation

PU

Cover E09 200x253 L=400mm AK 250x70 Cover E09 200x253 L=400mm AK 300x70 Cover E09 200x253 L=400mm AK 350x70 Cover E09 200x253 L=400mm AK 400x70

1 1 1 1

Technical changes reserved

Order no.

AKM250200E09 AKM300200E09 AKM350200E09 AKM400200E09

119

electraplan.AK On-the-floor trunking

AKM250200Q06

Designation

electraplan.AK Accessories Side profile, length 2400 mm Properties: - Extruded aluminium profile - If additionally required for one-sided trunking lower part

Designation

PU

Order no.

Side profile with edge cap L=2400 mm AK

24

AKZSP2400

AKZSP2400

electraplan.AK On-the-floor trunking

Side profile, length 100 mm Properties: - Extruded aluminium profile - If additionally required for two-sided trunking lower part, or-one sided with extension Designation

PU

Side profile without edge cap L=100 mm AK

1

Order no.

AKZSP0100

AKZSP0100 Partition wall made from PS Properties: - Partition wall for division into trunking compartments - Including 4 partition wall feet to be glued into the trunking or for dowelling to the bare floor - Overall height with partition wall feet = nominal height a + 2.5 mm - Length 2000 mm - Material: Polystyrol BKTWK31 Designation

PU

Partition wall foot height 33 L=2m PS z BK/AK Partition wall foot height 63 L=2m PS z BK/AK

1 1

Order no.

BKTWK31 BKTWK61

Partition wall foot made from PS - If additionally required - Material: Polystyrol

Designation

PU

Partition wall foot for plastic TW for BK/AK

1

Order no.

BKTWF00

BKTWF00 Earth conductor for earthing the trunking system Properties: - Screws onto the straight trunking connector, flexible conductor 2.5 mm², 135 mm long, green-yellow - 2 x annular cable lug Designation

PU

Earthing conductor AK, length 135 mm, green-yellow

1

AKZSA0135

120

Technical changes reserved

Order no.

AKZSA0135

electraplan.AK Accessories Trunking connector Designation

PU

Trunking connector, straight, for AK 1 AKZKV180

1

Order no.

AKZKV180

AKZKV180

Designation

PU

Trunking connector, angled 90°, for AK

1

Order no.

AKZKV090

AKZKV090

Technical changes reserved

121

electraplan.AK On-the-floor trunking

Trunking connector, angled

On-the-floor trunking, aluminium - Safer protection at higher loads - Easily accessible through removable upper part - Separate compartments for separation of power and data lines

Floor distributor colours RAL 7035 light grey RAL 7021 anthracite

Supplied lengths 2000 mm, special lengths up to 6000 mm on request

Material Anodised aluminium

Form of delivery Complete trunking with lower and upper part

electraplan.AK On-the-floor trunking

On-the-floor trunking, aluminium

AKA181250ELN

Complete trunking with lower and upper part, with removable upper part Laying of cables from above Height 18 mm, width 125 mm, 2 compartments Line configuration: 8 x ø 11 mm e.g. NYM 3 x 1.5 mm² Upper part BRAN700802ELN as replacement part Designation

PU

Order no.

On-the-floor trunking, aluminium AKA 18x125mm anodised Dado runking-OT to BRAN, 80mm, anodised

12 32

AKA181250ELN BRAN700802ELN

Designation

PU

Order no.

Double sided adhesive tape, width 19 mm L=5 m 1 L5106

1

Double sided adhesive tape Roll length 50 m, width 19 mm L5106

L5106

Floor distributor, complete For transition from aluminium on-the-floor trunking to upper and lower parts consisting of flat chain Material: Steel sheet

G71357035

Designation

PU

Floor distributor, flat chain and on-the-floor trunking, light grey Floor distributor, flat chain and on-the-floor trunking, anthracite

1 1

Order no.

G71357035 G71357021

Floor distributor, upper part Junction and cross piece for aluminium on-the-floor trunking, upper part from steel sheet

G71407035

Designation

PU

Floor distributor upper part flat chain//on-the-floor trunking light grey Floor distributor upper part flat chain//on-the-floor trunking anthracite

1 1

Order no.

G71407035 G71407021

On-the-floor trunking, lower part PVC, upper part aluminium 4 compartments Line configuration: 4 x ø 11 mm e.g. NYM 3 x 1.5 mm² SLA180750ELN

Designation

PU

Order no.

On-the-floor trunking with upper part aluminium SLA 18x75 anodised

10

SLA180750ELN

Designation

PU

Order no.

Earthing connection in kit (5 pieces) for SLA-OT 1 L5806

1

Earthing accessory for SLA180750ELN

L5806

L5806 Earthing conductor - plug-in, cross-section 4 mm2, for electrical connection of base profiles and upper parts and for by-passing moulded parts L4181GNGE

122

Designation

PU

Earthing conductor length 150 mm green-yellow Earthing conductor length 300 mm green-yellow Earthing conductor length 600 mm green-yellow

100 100 25

Technical changes reserved

Order no.

L4181GNGE L4182GNGE L4183GNGE

On-the-floor trunking, PVC On-the-floor trunking - for flexible wire transport on floors - hard wearing

Delivery colours RAL 7030, grey RAL 7035, light grey RAL 1019, beige RAL 8014, brown RAL 7021, anthracite RAL 9001, cream white RAL 9010, pure white

Material PVC Supplied lengths 2000 mm

On-the-floor trunking, PVC 1 compartment Line configuration: 1 x ø 11 mm e.g. NYM 3 x 1.5 mm² Designation

PU

Order no.

On-the-floor trunking, PVC SL 11x40 mm, stone grey On-the-floor trunking, PVC SL 11x40 mm, cream white

70 70

SL1104007030 SL1104009001

On-the-floor trunking, PVC 4 compartments Line configuration: 4 x ø 11 mm e.g. NYM 3 x 1.5 mm²

SL1807509001

Designation

PU

Order no.

On-the-floor trunking PVC SL 18x75 mm beige On-the-floor trunking PVC SL 18x75 mm anthracite On-the-floor trunking PVC SL 18x75 mm stone grey On-the-floor trunking PVC SL 18x75 mm light grey On-the-floor trunking PVC SL 18x75 mm brown On-the-floor trunking PVC SL 18x75 mm cream white On-the-floor trunking PVC SL 18x75 mm pure white

32 32 32 32 32 32 32

SL1807501019 SL1807507021 SL1807507030 SL1807507035 SL1807508014 SL1807509001 SL1807509010

Technical changes reserved

123

electraplan.AK On-the-floor trunking

SL1104007030

electraplan.AK Order number composition

electraplan.AK On-the-floor trunking

On-the-floor trunking Identifier number

Type

Trunking width

Trunking height

Splay/Extension

AK = On-the-floor trunking

U

X

Y

Z

150 = 150 mm 200 = 200 mm 250 = 250 mm 300 = 300 mm 350 = 350 mm 400 = 400 mm

040 = 40 mm 070 = 70 mm

1 = single-sided 2 = double-sided

= Lower part

E = End piece B8 = Blank cover, length 800 mm B4 = Blank cover, length 400 mm BAS = Blank cover, length 800 mm, with connection BAZ = Blank cover, length 800 mm, with 45 degree junction BI = Blank cover, inner corner BA = Blank cover, outer corner

1V = 100 mm extension

Covers with installation opening Identifier

Type

Nominal width

Size and type of blanking

AK = On-the-floor trunking

X

Y

Z

M = Cover with installation opening

150 = 150 mm 200 = 200 mm 250 = 250 mm 300 = 300 mm 350 = 350 mm 400 = 400 mm

050GBZ = Blanking GBZ round 50 mm 215R06 = Blanking R06 round 215 mm 275R10 = Blanking R10 round 275 mm 306R12 = Blanking R12 round 306 mm 200Q06 = Blanking Q06 200 x 200 mm 294Q08 = Blanking Q08 294 x 294 mm 244Q12 = Blanking Q12 244 x 244 mm 147E04 = Blanking E04 147 x 247 mm 200E09 = Blanking E09 200 x 253 mm

AK Zubehör Identifier

Type

Type

Length/Angle

AK = On-the-floor trunking

X

Y

Z

Z = Accessory

SP = Side profile

0100 = Length 100 mm 2400 = Length 2400 mm

SA = Earthing conductor connection

0135 = Length 135 mm

KV = Trunking connector

090 = angle, 90 degrees 180 = straight, 180 degrees

124

Technical changes reserved

electraplan.AK On-the-floor trunking system General description - Operating principle and application

This trunking system is particularly suitable for renovation projects as well as for modernisation and expansion of building installations. The main areas of use are renovation projects in office and administration buildings, and construction projects requiring a rapid production of electrical systems on already finished floors. If installation of underfloor trunking in the screed is not possible due to a building structure that is protected for structural reasons or due to historical monument regulations, on-the-floor trunking can be routed on the finished floors. However, this robust on-the-floor trunking is also used in assembly shops, laboratories and industrial buildings.

Technical changes reserved

125

electraplan.AK On-the-floor trunking

The on-the-floor trunking system is installed on finished floors. Hager on-the-floor trunking can be harmoniously integrated into the interior architecture without a large amount of installation work. Proven installation and construction units provide flexible space distribution and complete the appearance of the installation. The on-the-floor trunking consists of a trunking lower-part (trough), which is fixed on the existing floor. Niches for radiators or other protrusions in the wall are ignored and are simply filled with the filler material, e.g. screed, and covered with the newly laid flooring. The cover of the trunking consists of a blank cover bevelled to the floor, which can also be provided with a floor covering. It is possible to use the covers with installation openings, installed units and service units, as well as with pedestal boxes protruding above the floor or to install service posts. Upper parts with a 100 mm wide overhang can be used to cover heating pipes, for example, installed in the floor area.

electraplan.AK On-the-floor trunking system Advantages at a glance Flexible retrofit installation If the floor is already finished or if subsequent cutting is not desired, the on-the-floor trunking system offers a quick and flexible installation. With this trunking system, subsequent changes do not present a problem. The position of the individual covers with installation openings can be changed as required, at any time. Robust quality Thanks to the 3-mm thick blank covers, made from galvanised steel sheet in accordance with DIN EN 10327, the on-the-floor trunking system is highly stable.

electraplan.AK On-the-floor trunking

Easy installation The preassembled moulded parts enable quick and simple modular assembly on the construction site.

126

Technical changes reserved

electraplan.AK Line volumes Determining the line volumes

electraplan.AK On-the-floor trunking

The line volumes are required in order to determine the correct trunking size. Since, in practice, the lines never lie entirely parallel to one another in the optimum space-saving manner, the quadratic (d)² diameter formula is used here. In order to be prepared for any later retrofitting, the channels should only be 50% filled. This also makes it easier to feed the lines through the trunking. In addition, it should be noted that this calculation does not take into account any floor boxes or outlets, which may interrupt the path of the lines. In practice, power and data cables are laid separated from each other in the trunking. Partitions divide the trunking into several compartments. If this applies in your case, calculate the individual space requirement for each compartment. You will find a line volume configurator at www.Hager.de/Konfigurator, which will help you with the calculation.

50 % sa

fety fac

Order number AKU1500401 AKU2000401 AKU2500401 AKU3000401 AKU1500701 AKU2000701 AKU2500701 AKU3000701 AKU3500701 AKU4000701

Trunking width mm 150 200 250 300 150 200 250 300 350 400

Usable crosssection cm² 60 80 100 120 105 140 175 210 245 280

tor

Line diameter in mm 5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

120 160 200 240 210 280 350 420 490 560

83 111 138 166 145 194 243 291 340 388

61 81 102 122 107 142 178 214 250 285

46 62 78 93 82 109 136 164 191 218

37 49 61 74 64 86 108 129 151 172

30 40 50 60 52 70 87 105 122 140

24 33 41 49 43 57 72 86 101 115

20 27 34 41 36 48 60 72 85 97

17 23 29 35 31 41 51 62 72 82

15 20 25 30 26 35 44 53 62 71

13 17 22 26 23 31 38 46 54 62

11 15 19 23 20 27 34 41 47 54

10 13 17 20 18 24 30 36 42 48

9 12 15 18 16 21 27 32 37 43

8 11 13 16 14 19 24 29 33 38

7 10 12 15 13 17 21 26 30 35

Technical changes reserved

127

electraplan.AK Installation instructions, on-the-floor trunking system General information: Wall Wall openings should be produced prior to installation of the trunking. Cleaning The installation surface must be clean and flat. Deburring Sharp corners and edges are to be avoided.

electraplan.AK On-the-floor trunking

Lower part fastening Trunking lower parts must be installed on the bare floor before putting down the flooring. Floor laying The flooring must be laid up to the trunking lower parts. Earthing The system components are to be included in the earthing measures, in accordance with DIN VDE 0100. Screwing Trunking covers must be securely and permanently screwed to the lower parts.

Fastening trunking lower parts to the bare floor

Inserting side profiles (long)

Inserting side profiles (short)

Lay the trunking lower parts together in the required position and fasten on to the bare floor.

Slide the (long) side profiles on the rear side of the trunking lower part, orientated towards the wall.

Slide the (short) side profiles on the front side of the trunking lower part. Align the profile pieces so that they later lie under under the fixing holes of the covers, separation approx. 400 mm.

Profiles for trunking lower parts AKU...

Inserting trunking connectors

Trunking partition wall BKTWK

In the case of trunking lower parts AKU…2 (for double-sided bevelled blank covers) the (short) side profiles are also used on the rear side, oriented towards the wall.

Fasten the (long) side profiles together using trunking connectors.

Trunking partition wall BKTWK Glue the trunking partition wall feet BKTWK into the trunking the lower part, at a separation of 500 mm. Insert the partition in the feet.

128

Technical changes reserved

Trunking partition wall BKTWK

Trunking end pieces

Earthing

Optional partition wall BKTWS is already installed in the factory.

Screw the trunking end pieces into the side profile as shown in the illustration.

Earth conductor cable AKZSA0135 is screwed to the connector. The profile must be connected conductively to the trunking lower part (trough) on-site. Drill holes in the side profile and screw in a self-tapping screw until it presses tightly against the trough.

Angle setting

Screwing trunking connectors

Applying blank covers

Lay the trunking lower parts flush to one another in the angle. Saw the (long) side profile on a mitre and screw to the angle connectors.

Screw the (short) side profiles to the angle connectors.

Screw the blank cover inner corners or blank cover outer corners, which have been cut on a 90° mitre in the factory, into the side profiles.

Laying flooring

Flooring on blank cover

Screwing on blank covers

Lay the flooring up to the trunking lower parts of the installed on-the-floor trunking system.

Glue the flooring to completely cover the blank cover. Then, where necessary, cut out installation openings in the flooring.

Screw the blank covers on the trunking lower parts. Align the (short) side profiles under the drilled holes. Insert bolts through the flooring, then insert screws in the profile slots and tighten. In this way, the screws remain easily accessible for later revisions.

Technical changes reserved

129

electraplan.AK On-the-floor trunking

electraplan.AK Installation instructions, on-the-floor trunking system

Double floors and cavity floors

electraplan.DB-HB

electraplan.DB-HB

Two systems in one Whether for stacked double floors or cavity floors with a closed screed covering – in both cases, the flexible electraplan.DB-HB system is the perfect solution: With pre-assembled lines and device casings with sockets, the final installation is simply a case of plugging in the electrical distribution. And with this practical plug-and-play technology, changes can be implemented quickly and easily.

System overview

132

Casing elements for supply units and height-adjustable cassettes

133

Cable outlets with a clamping range less than than 20 mm

134

Cable outlets with a clamping range greater than 20 mm

135

Flat chain and accessories

136

Round chain and accessories

138

Order number system

139

Technical information

140

electraplan.DB-HB

electraplan.DB-HB

131

electraplan.DB-HB System overview

5

7

electraplan.DB-HB

2

4

3

6

1

electraplan.DB-HB 1 Cable outlet with connection for round chain 2 Cable outlet with connection for flat chain 2 Round chain 4  Flat chain 5  Connection adapter for round chain 6  Connection adapter for flat chain 7 Rosette for round chain

132

Technical changes reserved

electraplan.DB-HB Casing elements for supply units and height-adjustable cassettes - Standard height: 50 mm - Casing elements also available on request with a height of 110 mm

Material Plastic

Note - Position the casing elements on the floor before casting the screed - Once the screed has set and reached the required hardness, cut off the protruding pType from the casing element

Shapes R06: round 215 mm R10: round 275 mm R12: round 306 mm Q06: square 200 x 200 mm Q12: square 244 x 244 mm E09: rectangular 200 x 253 mm

SEVR0650

Designation

PU

Order no.

Casing element f VR06 round 215mm H50mm Casing element f VR10 round 275mm H50mm Casing element f VR12 round 306mm H50mm Casing element f VQ06 square 200mm H50mm Casing element f VQ12 square 244mm H50mm Casing element f VE09 200x253mm H50mm

15 10 1 25 1 1

SEVR0650 SEVR1050 SEVR1250 SEVQ0650 SEVQ1250 SEVE0950

Properties: - 350 x 350 mm - For use with e.g. cavity floors Designation

PU

Formwork element base support 350x350 mm

1

Order no.

SEGT350

SEGT350

Formwork elements for service units and height adjustable cassettes Properties: - height 200 mm - in 5 segments with 40 mm height, divisible, can thus be matched with floor construction height

SEVR06200

Designation

PU

Formwork element VE04 147x247mm H=200mm Formwork element VE09 200x253mm H=200mm Formwork element VR06 rund 215mm H=200mm Formwork element VR2 rund 242mm H=200mm Formwork element VR10 rund 275mm H=200mm Formwork element VR12 rund 306mm H=200mm Formwork element VQ06 200x200mm H=200mm Formwork element VQ12 244x244mm H=200mm Formwork element VQ08 294x294mm H=200mm

1 1 1 1 1 1 1 1 1

Technical changes reserved

Order no.

SEVE04200 SEVE09200 SEVR06200 SEVR2200 SEVR10200 SEVR12200 SEVQ06200 SEVQ12200 SEVQ08200

133

electraplan.DB-HB

Casing elements for supply units and height-adjustable cassettes

electraplan.DB-HB Cable outlets with a clamping range greater than 20 mm - For installation in double or cavity floors - Clamping range greater than 20 mm - Outer diameter: 132 mm - Installation opening: 112 mm

Material Polyamide (halogen-free) Available colours RAL 7011, iron grey RAL 9005, deep black RAL 7035, light grey

Cable outlet for dry-cleaned floors Properties: - With connection for flat chain

electraplan.DB-HB

LAFKG207011

Designation

PU

Cable outlet f fl chain clamp>20mm eg Cable outlet f fl chain clamp>20mm lg Cable outlet f fl chain clamp>20mm ts

1 1 1

Order no.

LAFKG207011 LAFKG207035 LAFKG209005

Cable outlet for dry-cleaned floors Properties: - With connection for round chain

LARKG207011

Designation

PU

Cable outlet f rd chain clamp>20mm eg Cable outlet f rd chain clamp>20mm lg Cable outlet f rd chain clamp>20mm ts

1 1 1

Order no.

LARKG207011 LARKG207035 LARKG209005

Cable outlet for wet-cleaned floors Properties: - With integrated splashwater protection

LATUG207011

Designation

PU

Cable outlet, tube, wet-cleaned fl. clamp>20mm eg Cable outlet, tube, wet-cleaned fl. clamp>20mm lg Cable outlet, tube, wet-cleaned fl. clamp>20mm ts

1 1 1

Order no.

LATUG207011 LATUG207035 LATUG209005

Blank cover with steel plate inlay

LABLG207011

134

Designation

PU

Cable outlet bl. cov. clamp>20mm eg Cable outlet bl. cov. clamp>20mm lg Cable outlet bl. cov. clamp>20mm ts

1 1 1

Technical changes reserved

Order no.

LABLG207011 LABLG207035 LABLG209005

electraplan.DB-HB Cable outlets with a clamping range less than 20 mm - For installation in double or cavity floors - Clamping range less than 20 mm - Outer diameter: 132 mm - Installation opening: 112 mm

Material Polyamide (halogen-free) Available colours RAL 7011, iron grey RAL 9005, deep black RAL 7035, light grey

Cable outlet for dry-cleaned floors Properties: - With connection for flat chain

PU

Cable outlet f fl chain clamp