Tyco International And
Tyco Thermal Controls Tyco Thermal Controls Proprietary
Tyco International : 5 Business Segments ADT Worldwide
Safety Products
Electrical and Metal Products
World’s largest electronic security and alarm monitoring provider to residential, commercial, industrial and governmental customers.
Design, manufacture and sell fire detection and fire suppression products, breathing apparatus, intrusion security, access control, video management systems, electronic article surveillance & RFID.
Design, manufacture and sell galvanized steel tubes, armored wire & cable and other metal products for construction, electrical, fire and security, mechanical and automotive customers.
Fire Protection Services
Flow Control
Leader in fire and life safety including fire detection, fire suppression and special-hazard solutions used to protect commercial, industrial and institutional customers around the world.
World’s largest manufacturer of flow control products and heat-tracing solutions for the oil and gas, power, food and beverage, chemical, water and other process industries.
Tyco Thermal Controls Proprietary
What We Offer Thermal Solutions…
Heat-Tracing
Specialty Heaters
Floor Heating
Installation Services Fire-Rated Wiring Products
Temperature Measurement
Leak Detection
3 Tyco Thermal Controls Proprietary
Electric Heat Tracing 구성도
(컨트롤 판넬)
변압기 Power 연결 kit Power Cable Tray
Thermostat or Controller (필요시)
End Seal 히팅케이블
Tyco Thermal Controls Proprietary
What is Electric Heat Tracing?
배관에 흐르는 유체는 보온을 하여도 보온재를 통해서 열이 외부로 유출 되므로 파이프를 따라서 열원을 보충하여 (열손실
TFluid
을 보상) 유체의 온도를 일정 하게 유지시켜 유체가 원활이 흐르도록 하는것.
TAmbient Ambient Heat Tracing
Tyco Thermal Controls Proprietary
Heat Tracing Maintains Temperature Over Time
Not Not Traced Traced
Fluid Fluid Temperature Temperature
Time Time (hrs) (hrs) Insulated Insulated Traced Traced
Fluid Fluid Temperature Temperature
Time Time (hrs) (hrs)
Un-insulated Un-insulated Traced Traced
Fluid Fluid Temperature Temperature
Time Time (hrs) (hrs) Tyco Thermal Controls Proprietary
Electric Tracing Solutions for All Those Applications
464 240
Maintain Temp. (ºF/ ºC)
428 220 392 200
Mineral Insulated Powerlimiting
Skin-effect Tracing System (STS)
356 180 320 160 284 140 248 120 212 100
XTV QTVR
SC
176 80
VLKTV
140 60 104 40
BTV
LBTV LBTV
VLBTV
SLBTV
68 20 0
50 164
150 492
250 820
400 1312
500 1640
700 2297
1000 3281
1500 4921
Maximum circuit length (ft/m)
Tyco Thermal Controls Proprietary
2000 6562
2500 20 kms. 8202 12000 12 miles
Electric Heat-Tracing Cable Technologies Self-regulating (BTV, QTVR, XTV) cable Power-limiting heating cable (VPL) Mineral insulated (MI) cable Longline heating –
Self-regulating (SLBTV, LBTV, VLBTV, VLKTV)
–
Series cables (SC)
–
Skin-effect heat tracing (STS)
Tyco Thermal Controls Proprietary
Power Power
Power Power
Temperature Temperature
Temperature Temperature
온도에 따라 출력이 변화됨
Temperature Temperature
Power-limiting
Self-regulating
Power Power
Technology Snapshot:
Linear power temperature curve
Series
- Constant power output - 낮은 초기 전류
- 고온에서도 높은 출력을 유지 한다. -초기 전류가 낮다
파이프온도가 증가되면 출력이 감소됨
Max. sheath temperature must be calculated with TraceCalc
절대적인 T-rating 가능
T-rating to be recorded in design documentation
T-rating 케이블 자켓에 표시됨
T-ratings are determined by (Stabilized design), or use a dual control with high temperature cut-out
Temperature control is required
Overlap = 절대 허용 안됨
Overlap = once allowed
겹쳐서 사용이 가능함 Tyco Thermal Controls Proprietary
Flat power temperature curve
Raychem Self-Regulating Cables Inventor of self-regulating cables Cut-to-Length Capability: No preengineered lengths Regulated Power Output: Lower operating cost and uniform pipe temperature Unconditional T-rating: Safe and easy system design
Self Regulating Parallel Circuit
Cross-linking Technology: Increased product life, highly reliable No Overheating at Cross-over: Faster and easier installation Tyco Thermal Controls Proprietary
BTV, QTVR, XTV
Self-Regulating Technology Regulated heat due to polymer core expansion and contraction with temperature
More heat where it is needed = higher system performance confidence Proven product = 10 year warranty More Than a Billion Feet of Safe, Sure Heat Tyco Thermal Controls Proprietary
Power Power
Power output varies with temperature
Temperature Temperature
Raychem Self-Regulating Cables BTV
QTVR
XTV
150°F maximum maintain temperature
225°F maximum maintain temperature
250°F maximum maintain temperature
185°F maximum intermittent exposure temperature
225°F maximum intermittent exposure temperature
420°F maximum intermittent exposure temperature
Power at 50°F: 3, 5, 8, 10 W/ft
Power at 50°F: 10, 15, 20 W/ft
Power at 50°F: 5, 10, 15, 20 W/ft
Freeze (frost) protection and
Freeze (frost) protection of
Freeze (frost) protection and
process temperature maintenance
large pipes and process temperature maintenance
T6 Temperature Rating
Higher wattage than BTV
Temperature sensitive
T4 Temperature Rating
applications
–Fuel
–Safety –Fire
showers
water lines
–Chocolate –Caustic
Pipes which are steam
cleaned T2 to T3 Temperature Rating
Used for:
Used for:
process temperature maintenance
oils
–Acids –Fertilizers
production
Used for: –Oils –Polymers –Heavy
lines Tyco Thermal Controls Proprietary
fuels
Raychem Power-Limiting Cables (VPL) Cut-to-length heater with higher wattage at higher temperatures Safely permits overlap without damage from overheating High performance jacket Withstands continuous to 500°F (260°C) Can be used at 480 V Lower sheath temperature than MI cables
Tyco Thermal Controls Proprietary
VPL Cable
Power-Limiting Technology Patented heating element provides
positive temperature coefficient (PTC) effect
Parallel Parallel Heating Heating Circuit Circuit
Node Node connection connection
Heating Heating element element (resistance (resistance wire) wire)
+
Fewer number of traces compared
to SR heaters at high maintain temperatures Fewer number of traces compared
Bus Bus wires wires
Zone Zone
to MI heaters due to lower sheath temperatures Can maintain up to 455°F(235°C)
depending on the product wattage Can go longer circuit lengths
especially at 480 V Tyco Thermal Controls Proprietary
VPL Cable
Raychem Connection Kits E-100
JBM-100-L
S-150
T-100 E-100-L JBS-100
E-150
Tyco Thermal Controls Proprietary
Connection Kits: Value Through Design Tyco Thermal Controls offers the most advanced
connection kits in the industry Patented Cold-Applied system – No hot work permit required – No RTV = no curing time
Reliable cage clamp (Wago) terminal connections – No vibration sensitivity – Accessible front entry
Fewer Parts : – Only 8 parts per JBS-100. – Captive Screws
Engineered Plastics, Easy to Insulate Around Faster and Reliable Terminations. – Fewer kits that do more Tyco Thermal Controls Proprietary
Pyrotenax Mineral Insulated Cables High temperature capability Rugged outer jacket Seamless Technology Output to 82 watts/ft Rated to 600 Vac
MI Cable
Tyco Thermal Controls Proprietary
MI Cable Technology Inventor of MI product technology
Insulation (magnesium oxide dielectric)
Inorganic materials of construction Superior properties Constant power output Constant power on all noncopper conductors
Metal sheath Solid conductors
Proven product = 10 year warranty Lead wires
Gland fitting
Cold lead
Cold lead connection
Tyco Thermal Controls Proprietary
Heating element (length as specified) Termination
Heating Cable Temperature Ranges 1200ºF
Maximum Exposure Temperature (ºF)
MI
500ºF
VPL
420ºF
XTV
225ºF
QTVR 185ºF
BTV
150ºF
225ºF
250ºF >300ºF
Maximum Maintain Temperature (ºF)
Tyco Thermal Controls Proprietary
Longline Heating Cables Three technologies cover all long line applications –
Self Regulating
–
Series
–
Skin effect
FM, CSA approved for hazardous
and non-hazardous area 500 ft (152 m) to 15 miles (24 kms)
from one power source Engineered design
Tyco Thermal Controls Proprietary
SR, Series, Skin effect
Raychem Longline Self-Regulating Heating Cables VLBTV and VLKTV are unique self-regulating long line heaters
NEUTRAL WIRE PHASE WIRES
480 or 600 Vac, 3-phase, 4-wire power supply FM, CSA approved for CID2 areas 500 ft (152 m) to 15 miles (24 kms.) Contact Tyco Thermal Controls for design
SELF-REGULATING CORE PRIMARY INSULATING JACKET Ni-Cu BRAID OUTER INSULATING JACKET
P1 P2 P3 N
Wiring of VL-heaters SLBTV, LBTV, VLBTV, VLKTV
Tyco Thermal Controls Proprietary
Raychem Longline Series Cables (SC) Polymeric, field terminable, flexible
constant wattage series heaters Single, dual, and triple conductor cables,
max 600 Vac Easy to monitor current Long circuit lengths, 1000 ft (300 m) to
12,000 ft (3659 m) Rugged resistance wire Maintain temperatures to 200°F (100°C) Exposure temperatures to 482°F (250°C) Contact Tyco Thermal Controls for
design
Tyco Thermal Controls Proprietary
Tracer Skin-Effect Tracing System STS technology around since 1970’s Used for circuit lengths up to 12 miles and
wattages up to 65 W/ft Single insulated conductor inside a ferromagnetic heat tube Series heating circuit: Current flows through the wire to the end and returns through the heat tube Heating element (steel heat tube) is typically welded to the traced pipe Custom engineered for each application
Circuit length determined by: –
Power output Heat tube and conductor size
–
Carrier pipe temperature
–
Tyco Thermal Controls Proprietary
Electric Tracing Solutions for a Wide Variety of Applications
464 240
Maintain Temp. (ºF/ ºC)
428 220 392 200
Mineral Insulated Powerlimiting
Skin-effect Tracing System (STS)
356 180 320 160 284 140 248 120 212 100
XTV QTVR
SC
176 80
VLKTV
140 60 104 40
BTV
LBTV LBTV
VLBTV
SLBTV
68 20 0
50 164
150 492
250 820
400 1312
500 1640
700 2297
1000 3281
1500 4921
Maximum circuit length (ft/m)
Tyco Thermal Controls Proprietary
2000 6562
2500 20 kms. 8202 12000 12 miles
DigiTrace NGC-30 System The advanced multicircuit control, monitoring and power distribution system for heat-tracing applications
Tyco Thermal Controls Proprietary
NGC-30 System Features and Benefits: Advanced Touch screen technology for user
interface DigiTrace Supervisory software with data logging
capabilities for trending, fault finding and other analysis Control and monitoring of up to 260 circuits Multi-Circuit architecture (5 circuits per board) 388 RTD inputs for precise circuit monitoring and
control Monitors temperature, ground-fault currents,
operating currents and voltages Ordinary and hazardous area locations DigiTrace NGC30 Tyco Thermal Controls Proprietary
Heat Trace Power Distribution Panels Dedicated power-distribution panels
reduce costly field wiring and controller cost Complete line available with: –
Individual or group control
–
Dedicated power distribution, control, monitoring and alarm panel
–
30-mA GFCB per National Electrical Code
–
NEMA 12, 4, 4X stainless steel enclosure HTPG and HTPI
Tyco Thermal Controls Proprietary
Heat-Traced Safety Stations Pre-Traced Eyewash Safety Station Simplified Field Installation Requirements Control Options Heat-Trace Indicator Light Shower Location Light System Safety Valves Annunciation ShowerGuard
Tyco Thermal Controls Proprietary
Tank Heating (RHS) Flexible Rugged Single person install For metal and plastic tanks High temperature protection Reliable
RHS Tank Heating
Tyco Thermal Controls Proprietary
Tank Insulation Systems Cost effective Maintenance free Eliminates expensive scaffolding Designed for hurricane force winds No horizontal bands Continuous 360° interlocking
seams provides rigidity Structurally superior vs. conventional
application Single panels may be replaced if damaged Trac-Loc
Tyco Thermal Controls Proprietary
Tubing Bundles Three products create one system Full range of cables and tubing materials, custom configurations Wide temperature limits Chloride free Easy to read foot / meter markings UV resistant FM approved Cl. I,II Div.2 CSA certified to Cl. I, II Div.1,2 Tyco Thermal Controls Proprietary
Tubing Bundles
Pipe Supports Patented clamp-on design Reduced cross-sectional area Less heater cable required “BEST” support for heattrace applications = Lower total installed cost
Interlock
Tyco Thermal Controls Proprietary
Fire-Rated Wiring Wiring designed to maintain circuit integrity while engulfed in fire conditions
Tyco Thermal Controls Proprietary
Fire-Rated Wiring
VITALink : Flexible, easy to install polymeric wiring for fire-rated applications
Tyco Thermal Controls Proprietary
Fire-Rated Wiring
Pyrotenax : Rugged, mineral insulated wiring for fire rated and high temperature applications
Tyco Thermal Controls Proprietary
Snow Melting and De-Icing Snow melting: Raychem ElectroMelt and Pyrotenax MI Heating Cables Roof and gutter de-icing: Raychem IceStop Snow and Ice Sensors adjust output for energy efficiency –
Ramps
–
Loading Docks
–
Walkways
–
Roofs, Gutters, Downspouts
Copper MI, IceStop and ElectroMelt
Tyco Thermal Controls Proprietary
Design Software- TraceCalc Pro The Industry Standard for Heat-
Tracing Design™ User-friendly Windows® feature
application software supports self-regulating and other technologies Calculates and selects
appropriate heat-tracing products Generates reports that can
be e-mailed Worldwide support
Tyco Thermal Controls Proprietary
Tyco Thermal Controls Customer Support 1800-545-6258 –
Order Status and Delivery
–
Product and Services information
–
Design/Technical support
Web Services –
Literature, Specifications – PDFs
–
Engineering Software
TraceCalc Pro DigiTrace Supervisory Software –
On-line design wizard
–
FAQ Section
Tyco Thermal Controls Proprietary
Tr a c e C ait'sl cthatPsimple ro
Design & Installation Tools Product selection and design guide –
Bound catalog
–
CD version
Pocket guide installation operation and maintenance manuals Engineering specifications
Tyco Thermal Controls Proprietary
Tyco Thermal Controls Proprietary
Offshore application summary System Heat tracing
Application Freeze protection
Drilling module
Processing module
Drilling water pipe,
Injection water pipe; Process pipe, valve, instrument, processing waste water
Mud pump, Kill and choke lines
(Self(Self-Regulating, Power limiting, MI heating, STS, DHSX) DHSX) Process temperature maintain
Down hole oil production tube
Utilities module Fire hydrant water pipe, Boiler pipe, Oil hydraulic unit
Accommodation module Potable water, waste water, Refrigerator hatches
Crude oil pipe,
Storage& Transport Export pipe
Oil flow lines, subsea pipeline
Gas pipe, Steam pipe, General process
Snow melting
Escape passage,
DeDe-icing
Doors/hatches, Walking deck, Helipad, Staircase, Handrail, GPS antenna
Comfort
Floor heating; Hot water
Leak Detection
Central room floor warming
Cabin floor warming, canting floor warming, hot water maintain Fresh water pipe
Oil pipeline
Emergency lighting
Emergency block valve
Safety leak detection
Crude oil pipe
Refrigerator water pipe
Tubing Bundle (O’brien, brien, RTB)
Instrument winterization
Offline instrument/analyzer
Offline instrument/analy zer
Industrial Wiring
Fire security
Emergency block valve
Fire pump wiring, emergency lighting
(TraceTek) TraceTek)
(Alloy 825)
Tyco Thermal Controls Proprietary
Thank You