TWN Uninterruptible Power System HP R1500 G4 INTL Uninterruptible Power System

QuickSpecs HP Line Interactive Single Phase UPS Overview and Models HP G4 Line Interactive Single Phase Uninterruptible Power Systems (UPS) Looking...
15 downloads 1 Views 1MB Size
QuickSpecs

HP Line Interactive Single Phase UPS

Overview and Models

HP G4 Line Interactive Single Phase Uninterruptible Power Systems (UPS) Looking for cost-effective power protection for your small office environments? HP Line Interactive Single Phase Uninterruptible Power System (UPS) solutions range from tower-based systems designed to safeguard tower servers and small office equipment, to rack-based systems that can protect a full rack of servers. Standard features include intuitive front panel displays for local management, and HP Enhance Battery Management (EBM) that help to extend the service-life of your batteries. HP Power Protection, a power management software application that ships with each model, combined with a UPS Network Module, optional on some models, enables you to remotely monitor and manage your UPS through HP Systems Insight Manager or via a standard web browser. When you need it, use outstanding HP support services for your whole data center environment. With HP Care Pack Services, have the security of knowing that your HP UPS will be covered at the same service level and coverage period as your HP server. HP UPSs are backed by a 3-year limited warranty, with the first year including parts and labor. Also, standard on all HP UPS units is our exclusive 30-day Battery Pre-Failure Warranty, which ensures that when customers receive notification from HP Power Manager Software that the battery may fail, the battery is replaced free of charge under the warranty. This warranty is offered worldwide. HP T750 G4 UPS Models HP T750 G4 NA/JP Uninterruptible Power System HP T750 G4 INTL Uninterruptible Power System HP T1000 G4 UPS Models HP T1000 G4 NA/JP Uninterruptible Power System HP T1000 G4 INTL Uninterruptible Power System HP T1500 G4 UPS Models HP T1500 G4 NA/JP Uninterruptible Power System HP T1500 G4 INTL Uninterruptible Power System R1500 G4 Models HP R1500 G4 NA Uninterruptible Power System HP R1500 G4 JP/TWN Uninterruptible Power System HP R1500 G4 INTL Uninterruptible Power System HP R/T2200 G4 UPS Models HP R/T2200 G4 NA/JP Uninterruptible Power System HP R/T3000 G4 UPS Models HP R/T3000 G4 Low Voltage NA/JP Uninterruptible Power System HP R/T3000 G4 High Voltage NA/JP Uninterruptible Power System HP R/T3000 G4 High Voltage INTL Uninterruptible Power System R5000 UPS Models HP R5KVA 3U L630 High Voltage NA/JP Uninterruptible Power System HP R5KVA 3U IEC309-32A High Voltage INTL Uninterruptible Power System R7000 UPS Models HP R7KVA 4U 50A High Voltage NA/JP Uninterruptible Power System HP R7KVA 4U IEC-32A High Voltage INTL Uninterruptible Power System

J2P85A J2P88A J2P86A J2P89A J2P87A J2P90A J2Q99A J2R05A J2R03A J2R00A J2R01A J2R02A J2R04A AF460A AF461A AF462A AF463A

What’s in the box     

USB communication cable Serial communication cable Additional jumper cords with the high voltage INTL model Rack mounting rails, mounting brackets, and/or cord retention clips (depends on model) Documentation

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 1

QuickSpecs

HP Line Interactive Single Phase UPS

HP Tower UPS Specifications

Tower UPS Rear Panel

HP T750 G4 UPS INTL

HP T1000 G4 UPS INTL

1. USB Communication Port 2. RS-232 Communication Port 3. Outlets for Connection of Critical Equipment

HP T750 G4 UPS NA/JPN 1. USB Communication Port 2. RS-232 Communication Port 3. Outlets for Connection of Critical Equipment

HP T1500 G4 UPS INTL

4. Socket for Connection to AC Power Source 5. Ground Screw

HP T1000 G4 UPS NA/JPN

HP T1500 G4 UPS NA/JPN

4. Attached 6-ft. Input Power Cord for AC Power Source 5. Ground Screw

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 2

QuickSpecs

HP Line Interactive Single Phase UPS

HP Tower UPS Specifications

Tower UPS Front Panel

6. ON/OFF Button 7. Scroll Button 8. Mute Alarm 9. UPS On 10. AVR Mode 11. Battery Mode

12. Internal Fault 13. Output Load Level 14. Battery Level 15. Input Measurements 16. Output Measurements 17. Measuring Unit

Tower UPS Models Provide Power Protection and Management Optimized for Smaller IT Environments Key Features  Manageability through USB and Serial ports  Ease of configuration via enhanced front panel display.  Intelligent manageability with bundled Power Manager software. NOTE: Certain restrictions and exclusions apply. Consult the HP Computer Support Center for details.

HP T750 G4 UPS Specifications See model matrix for other specifications. T750 G4, NA/JP Load Segments J2P85A Unit Dimensions (WxDxH) T750 G4, INTL Shipping Dimensions(LxWxH) J2P88A Unit Weight Shipping Weight

1 5.9 x 13.4 x 8.3 inch (150 x 340 x 210 mm) 18.7x 9.4 x 12.1 inch (476 x 238 x 308 mm) 23.6 lbs (10.7kg) 26.4 lbs (12 kg)

HP T1000 G4 UPS Specifications T1000 G4, NA/JP J2P86A T1000 G4, INTL J2P89A

Load Segments Unit Dimensions (WxDxH) Shipping Dimensions(LxWxH) Unit Weight Shipping Weight

1 5.9 x 13.4x 8.3 inch (150 x 340x 210 mm) 18.7 x 9.4 x 12.1 inch (476 x 238 x 308 mm) 25.1 lbs (11.4kg) 28.7 lbs (13 kg)

HP T1500 G4 UPS Specifications T1500 G4, NA/JP J2P87A T1500 G4, INTL J2P90A

Load Segments Unit Dimensions (WxDxH) Shipping Dimensions(LxWxH) Unit Weight

1 5.9 x 16.1 x 8.3inch (150 x 410 x 210 mm) 19.6 x 9.4 x 12.1 inch (498 x238 x 308 mm) 34.4 lbs (15.6 kg)

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 3

QuickSpecs

HP Line Interactive Single Phase UPS

HP Tower UPS Specifications Shipping Weight 37.3 lbs (16.9 kg) NOTE: Locate which Operating Systems are supported at: http://www.hp.com/products/powermanager.

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 4

QuickSpecs

HP Line Interactive Single Phase UPS

HP Rack UPS Specifications

HP R1500 G4 NA and JP/TWN UPS

1. IUSB Communication Port 2. ES-232 Communication Port 3. Slot for optional communication card 4. Connector for ROO(Remote On/Off) or RPO (Remote Power Off) Control 5. Outlets for connection of critical equipment (Primary group)

6a. Group 1: programmable outlets for equipment connection 6b. Group 2: programmable outlets for equipment connection 7. Attached 6ft input power cord Nema 5-15P for AC power source, 8. LED indicating site wiring fault alarm 9. Ground screw

HP R1500 G4 International UPS

1. USB communication port 2. RS-232 communication port 3. Slot for optional communication card

6a. Group 1: programmable outlets for equipment connection 6b Group 2: programmable outlets for equipment connection 7. Input power connection (IEC -320-C14) for powering unit to AC power source

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 5

QuickSpecs

HP Line Interactive Single Phase UPS

HP Rack UPS Specifications 4. Connector for ROO (Remote On/Off) or RPO (Remote Power Off) control 5. Outlets for connection of equipment (Primary group)

8. Ground screw

HP R/T2200 and R/T3000 Tower Uninterruptible Power System (UPS)

R/T3000 in Rack UPS configuration

R/T3000 with Tower UPS floor stands

R5000 UPS

Front View

Rear View

1. 2.

Escape Button Scroll up button

1. 2.

3.

Scroll down button

3.

ERM connector for the small plug on the split ERM cable Load segment 1 circuit breaker (controls the C19 and C13 receptacles, but does not control the large output receptacle) Load segment 1 (two IEC-320-C19 receptacles, two IEC320- C13 receptacles)

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 6

QuickSpecs

HP Line Interactive Single Phase UPS

HP Rack UPS Specifications 4. 5.

Enter/Select button Power button

4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.

Cord retention clip attachment locations Load segment 2 (two IEC-320-C19 receptacles and two IEC- 320-C13 receptacles) REPO port USB communications port Serial communications port HP UPS Network Module (included) Ground bonding screw Input power line cord with NEMA L6-30 plug Load segment 2 circuit breaker Large output NEMA L6-30R receptacle or IEC-309-32A receptacle associated with load segment 1 ERM Connector for large plug

R7000 UPS

Front View

Rear View

1.

Escape Button

1.

2.

Scroll up button

2.

3.

Scroll down button

3.

4. 5.

Enter/Select button Power button

4. 5. 6. 7. 8. 9. 10. 11. 12. 13.

Load segment 1 circuit breaker (controls L6-30R receptacle Item 3) Load segment 2 circuit breaker (controls L6-30R receptacle Item 15) Large output NEMA L6-30R receptacle or IEC-60309 32A receptacle on short cords associated with load segment 1 Cord retention clip attachment locations Load segment 1 circuit breaker (controls the C19 receptacles, but does not control the large output receptacle) 3 x IEC C19 receptacles on load segment 1 HP UPS Network Module Input power line cord with NEMA CS8265C plug or IEC309- 32A plug Ground bonding screw Serial communications port USB communications port REPO port 3 x IEC C19 receptacles on load segment 2

c04154342 – DA – 14058 Worldwide — Version 9 — June 4, 2015

Page 7

QuickSpecs

HP Line Interactive Single Phase UPS

HP Rack UPS Specifications 14.

Load segment 2 circuit breaker (controls the C19 receptacles, but does not control the large output receptacle)

Ultra-Dense Rack UPS Models Scale from Small to Enterprise IT Environments Key Features  Front panel LCD display  Enhanced system flexibility with two independently controlled load segments

Specifications HP R1500 G4 UPS Electrical Input

Electrical Output

Battery

Communications

Environmental and Safety

Unit Dimensions (LxWXH) Shipping Dimensions Unit Weight Shipping Weight

Voltage Range

± 15% of nominal100 and 120V models and ± 20% of nominal on 230V models. See Model Matrix for nominal and user selectable voltage settings via LCD Front Display Panel Frequency 50/60 Hz ± 5Hz (auto sensing at default voltage ) Online Efficiency 92% Online Regulation -10% to +6% of nominal voltage* On battery Regulation -10% / + 6%of nominal voltage Voltage Wave Form Sine wave Connections See Model Selection Matrix; divided into3 Load Segments Output Protection Firmware overload sensing and control, Type Maintenance-free, sealed, valve-regulated lead acid (VRLA) Backup Time See Backup Times Chart Recharge Time

Suggest Documents