Page 1 / 7
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006 as amended
____________________________________________________________________________________________ SDS # : A-12
Toner Drum Cartridge - Black
Issuing Date 1997-08-19
Revision Date 2016-06-22
Version 1
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING 1.1 Product identifier
Product Name
Toner Drum Cartridge for DocuPrint N2025, DocuPrint N2125, DocuPrint N2825, DocuPrint P12 PXV, Xerox Phaser 5400 Laser Printer
Part no.
113R00034, 113R00311, 113R00443, 113R00445, 113R00446, 113R00495, 013R00548, 673K35240, 673K51810, 673K53670, 673K59830, 673K06276
Colour
Black
1.2 Relevant identified uses of the substance or mixture and uses advised against Recommended Use
Xerographic printing
1.3 Details of the supplier of the safety data sheet Supplier
Xerox Ltd. Xerox Environment, Health & Safety Bessemer Road Welwyn Garden City Herts. AL7 1HE UK
For further information, please contact Manager, Environment, Health, Safety Contact person & Sustainability ++44 (0)1707 353434 Phone Fax
[email protected] E-mail address 1.4 Emergency telephone Not applicable
2. HAZARDS IDENTIFICATION 2.1 Classification of the substance or mixture According to present data no classification and labelling is required according to Regulation (EC) No 1272/2008 2.2 Label elements None 2.3 Other hazards No hazard expected under normal conditions of use
Page 2 / 7
____________________________________________________________________________________________ SDS # : A-12
Toner Drum Cartridge - Black
Issuing Date 1997-08-19
Revision Date 2016-06-22
Version 1
____________________________________________________________________________________________ 3. COMPOSITION/INFORMATION ON INGREDIENTS 3.1 Mixtures Chemical Name
Weight %
CAS No.
EC-No
Styrene/acrylate copolymer Iron oxide Polypropylene wax Amorphous silica
45-60 40-50 2-3 5 g/kg (rat) > 5 g/kg (rabbit) > 5 mg/L (rat, 4 hr)
Chronic toxicity Product Information Chronic effects Carcinogenicity
No known effects under normal use conditions Not classifiable as a human carcinogen
Other toxic effects Product Information Sensitisation Mutagenic effects Target organ effects
No sensitisation responses were observed Not mutagenic in AMES Test None known
Other adverse effects Aspiration Hazard
None known Not applicable
12. ECOLOGICAL INFORMATION 12.1 Toxicity Acute Aquatic Toxicity Chronic Aquatic Toxicity 12.2 Persistence and degradability Not readily biodegradable
On available data, substance is not harmful to aquatic life. On available data, substance is not harmful to aquatic life.
Page 6 / 7
____________________________________________________________________________________________ SDS # : A-12
Toner Drum Cartridge - Black
Issuing Date 1997-08-19
Revision Date 2016-06-22
Version 1
____________________________________________________________________________________________ 12.3 Bioaccumulative potential Bioaccumulation is unlikely 12.4 Mobility in soil Insoluble in water 12.5 Results of PBT and vPvB assessment Not a PBT according to REACH Annex XIII 12.6 Other adverse effects Presents little or no hazard to the environment
13. DISPOSAL CONSIDERATIONS 13.1 Disposal considerations Waste Disposal Method
No special precautions are needed in handling this material
EWC Waste Disposal No.
08 03 18
14. TRANSPORT INFORMATION 14.1 UN/ID No Not regulated 14.2 Proper shipping name Not regulated 14.3 Transport hazard class(es) Not classified 14.4 Packing Group Not applicable 14.5 Environmental hazards Presents little or no hazard to the environment 14.6 Special precautions for users No special precautions are needed in handling this material 14.7 Transport in bulk according to MARPOL 73/78 and the IBC Code
Page 7 / 7
____________________________________________________________________________________________ SDS # : A-12
Toner Drum Cartridge - Black
Issuing Date 1997-08-19
Revision Date 2016-06-22
Version 1
____________________________________________________________________________________________ Not applicable
15. REGULATORY INFORMATION 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture According to present data no classification and labelling is required according to Regulation (EC) No 1272/2008. 15.2 Chemical Safety Assessment Not applicable
16. OTHER INFORMATION Issuing Date Revision Date Revision Note
1997-08-19 2016-06-22
This safety data sheet complies with the requirements of Regulation (EC) No. 1272/2008 as amended. Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text.