Tiger Series MINI- IDE Flash Disk Industrial Application

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. Tiger Series MINI- IDE Flash Disk Industrial Application Product Specification V1...
Author: Angela Jennings
3 downloads 0 Views 2MB Size
Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp.

Tiger Series MINI- IDE Flash Disk Industrial Application Product Specification V1.1

Dec 2008

TCADO-SID-000009.2

1/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. Document History Description Version 1.0 New issued 1.1 Revise part no.

Date 2008/05/28 2008/12/24

Editor David Wu Amos

Approved by Matika Wang Matika Wang

This document provides information regarding to C-ONE’s MINI- IDE Flash Disk product specification and is subject to change without any prior notice. No part in this report shall be distributed, reproduced, or disclosed in whole or in part without prior written permission of C-ONE. All rights reserved. C-ONE Technology Corp. Ltd. TCADO-SID-000009.2

2/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp.

Contents INDUSTRIAL APPLICATION...............................................................................................................................................................................1 1.

INTRODUCTION...........................................................................................................................................................................................7 1.1

GENERAL DESCRIPTION...........................................................................................................................................................................7

1.2

FEATURES .................................................................................................................................................................................................8

2.

PRODUCT SPECIFICATION.....................................................................................................................................................................9 2.1

OPERATION AND ENVIRONMENT DESCRIPTION ......................................................................................................................................9

2.2

PHYSICAL DESCRIPTION.........................................................................................................................................................................10

3.

PRODUCT MODEL..................................................................................................................................................................................... 11 3.1

PART NUMBER DEFINITION ...................................................................................................................................................................11

3.2

40/44-PIN MINI IDE PLAIN FORM PICTURES AND PART NUMBER .....................................................................................................14

3.3

40-PIN MINI IDE L-FORM PICTURES AND PART NUMBER...................................................................................................................14

3.4

44-PIN MINI IDE L-FORM PICTURES AND PART NUMBER...................................................................................................................17

4.

SUPPORT FLASH MEDIA........................................................................................................................................................................21 4.1

SUPPORTED NAND FLASH TYPE .........................................................................................................................................................21

4.2

LOGICAL FORMAT PARAMETERS (CHS)...............................................................................................................................................21

5.

BLOCK DIAGRAM.....................................................................................................................................................................................22 5.1

CONTROLLER ARCHIVE .........................................................................................................................................................................22

5.2

FLASH CARD ARCHIVE ..........................................................................................................................................................................22

6.

SPECIFICATION AND FEATURES........................................................................................................................................................23 6.1

ELECTRICAL SPECIFICATION .................................................................................................................................................................23 6.1.1

Absolute Maximum Ratings ............................................................................................................................................................23

6.1.2

General DC Characteristic.............................................................................................................................................................23

6.1.3

DC Electrical Characteristics for 5 Volts Operation ....................................................................................................................23

6.1.4

DC Electrical Characteristics for 3.3 Volts Operation .................................................................................................................24

6.1.5

True IDE Mode I/O (Read/Write) Timing Specification................................................................................................................24

6.1.6

True IDE Ultra DMA Mode I/O (Read/Write) Timing Specification...........................................................................................25

6.1.6.1

Ultra DMA Data-In Burst Initiation Timing................................................................................................................................................26

6.1.6.2

Sustained Ultra DMA Data-In Burst Timing ..............................................................................................................................................27

6.1.6.3

Ultra DMA Data-In Burst Host Pause Timing............................................................................................................................................27

6.1.6.4

Ultra DMA Data-In Burst Device Termination Timing.............................................................................................................................28

6.1.6.5

Ultra DMA Data-In Burst Host Termination Timing.................................................................................................................................28

6.1.6.6

Ultra DMA Data-In Burst Host Termination Timing.................................................................................................................................29

6.1.6.7

Sustained Ultra DMA Data-Out Burst Timing ...........................................................................................................................................29

6.1.6.8

Ultra DMA Data-Out Burst Device Pause Timing.....................................................................................................................................30

TCADO-SID-000009.2

3/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 6.1.6.9

Ultra DMA Data-Out Burst Device Termination Timing ..........................................................................................................................30

6.1.6.10

Ultra DMA Data-Out Burst Host Termination Timing ..............................................................................................................................31

6.2

POWER MANAGEMENT..........................................................................................................................................................................31 6.2.1

Normal Mode...................................................................................................................................................................................31

6.2.2

Power down Mode...........................................................................................................................................................................31

6.3

PHYSICAL SPECIFICATION......................................................................................................................................................................32

6.3.1 MIDE 40 PIN P-FORM WITH HOUSING OUTLINE DIMENSIONS.....................................................................................................................32 6.3.2 MIDE 40 PIN L-FORM WITHOUT HOUSING OUTLINE DIMENSIONS .............................................................................................................33 6.3.3 MIDE 44-PIN P-FORM WITH HOUSING OUTLINE DIMENSION ......................................................................................................................34 6.3.4 MIDE 44-PIN L-FORM WITHOUT HOUSING OUTLINE DIMENSIONS.............................................................................................................35 7.

PIN ASSIGNMENT ......................................................................................................................................................................................36 7.1

PIN TYPE.................................................................................................................................................................................................36

7.2

INTERFACE SIGNALS DESCRIPTION.......................................................................................................................................................37

7.3

INSTALLING THE SSD DRIVE IN A TWO-DRIVE CONFIGURATION ......................................................................................................39

8.

ATA SPECIFIC REGISTER DEFINITIONS.........................................................................................................................................41 8.1

TRUE IDE MODE ...................................................................................................................................................................................41

8.2

9.

ATA REGISTERS .....................................................................................................................................................................................41 8.2.1

Data Register....................................................................................................................................................................................41

8.2.2

Error Register...................................................................................................................................................................................42

8.2.3

Feature Register...............................................................................................................................................................................42

8.2.4

Sector Count Register......................................................................................................................................................................42

8.2.5

Sector Number Register...................................................................................................................................................................43

8.2.6

Cylinder Low Register.....................................................................................................................................................................44

8.2.7

Cylinder High Register....................................................................................................................................................................44

8.2.8

Drive Head Register........................................................................................................................................................................45

8.2.9

Status Register..................................................................................................................................................................................46

8.2.10

Alternate Status Register............................................................................................................................................................46

8.2.11

Device Control Register.............................................................................................................................................................47

8.2.12

Drive Address Register...............................................................................................................................................................47

ATA COMMANDS........................................................................................................................................................................................48 9.1

CHECK POWER MODE - 98H OR E5H...................................................................................................................................................48

9.2

EXECUTE DRIVE DIAGNOSTIC - 90H....................................................................................................................................................49

9.3

ERASE SECTOR(S) - C0H .......................................................................................................................................................................50

9.4

FORMAT TRACK - 50H...........................................................................................................................................................................51

9.5

IDENTIFY DRIVE – ECH.........................................................................................................................................................................52

9.6

IDLE - 97H OR E3H................................................................................................................................................................................53

9.7

IDLE IMMEDIATE - 95H OR E1H............................................................................................................................................................54

9.8

INITIALIZE DRIVE PARAMETERS - 91H.................................................................................................................................................55

9.9 READ BUFFER - E4H..............................................................................................................................................................................56 TCADO-SID-000009.2 4/95 0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.10

READ LONG SECTOR(S) - 22H OR 23H.................................................................................................................................................57

9.11

READ MULTIPLE - C4H .........................................................................................................................................................................58

9.12

READ SECTORS(S) – 20H OR 21H.........................................................................................................................................................59

9.13

READ VERIFY SECTOR(S) – 40H OR 41H .............................................................................................................................................60

9.14

RECALIBRATE - 1XH..............................................................................................................................................................................61

9.15

REQUEST SENSE - 03H...........................................................................................................................................................................62

9.16

SEEK - 7XH ............................................................................................................................................................................................63

9.17

SET FEATURE - EFH...............................................................................................................................................................................64

9.18

SET MULTIPLE MODE - C6H.................................................................................................................................................................65

9.19

SET SLEEP MODE - 99H OR E6H...........................................................................................................................................................66

9.20

STANDBY - 96H OR E2H........................................................................................................................................................................67

9.21

STANDBY IMMEDIATE 94H OR E0H......................................................................................................................................................68

9.22

TRANSLATE SECTOR - 87H....................................................................................................................................................................69

9.23

WEAR LEVEL - F5H...............................................................................................................................................................................70

9.24

WRITE BUFFER - E8H............................................................................................................................................................................71

9.25

WRITE LONG SECTOR(S) 32H OR 33H .................................................................................................................................................72

9.26

WRITE MULTIPLE - C5H........................................................................................................................................................................73

9.27

WRITE MULTIPLE WITHOUT ERASE – CDH.........................................................................................................................................74

9.28

WRITE SECTOR(S) - 30H OR 31H..........................................................................................................................................................75

9.29

WRITE SECTOR(S) WITHOUT ERASE - 38H...........................................................................................................................................76

9.30

WRITE VERITY - 3CH............................................................................................................................................................................77

10.

ERROR POSTING..................................................................................................................................................................................78

11.

IDENTIFY DRIVE INFORMATION.......................................................................................................................................................79

12.

ATA PROTOCOL OVERVIEW...........................................................................................................................................................84 12.1

PIO DATA IN COMMANDS .....................................................................................................................................................................84

12.2

PIO DATA OUT COMMANDS .................................................................................................................................................................84

12.3

NON DATA COMMANDS.........................................................................................................................................................................84

14. ULTRA DMA DATA-IN COMMANDS........................................................................................................................................................85 14.1. INITIATING AN ULTRA DMA DATA-IN BURST ...............................................................................................................................................85 14.2. THE DATA-IN TRANSFER ................................................................................................................................................................................85 14.3. PAUSING AN ULTRA DMA DATA-IN BURST ..................................................................................................................................................86 14.3.1. Device pausing an Ultra DMA data-in burst.....................................................................................................................................86 14.3.2. Host pausing an Ultra DMA data-in burst.........................................................................................................................................86 14.3.3. Terminating an Ultra DMA data-in burst ..........................................................................................................................................86 14.3.3.1. Device terminating an Ultra DMA data-in burst..................................................................................................................................................86 14.3.3.2. Host terminating an Ultra DMA data-in burst......................................................................................................................................................87

14.4. ULTRA DMA DATA-OUT COMMANDS ...........................................................................................................................................................89 14.4.1. Initiating an Ultra DMA data-out burst .............................................................................................................................................89 14.4.2. The data-out transfer............................................................................................................................................................................89 TCADO-SID-000009.2 5/95 0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 14.4.3. Pausing an Ultra DMA data-out burst...............................................................................................................................................90 14.4.3.1 Host pausing an Ultra DMA data-out burst...........................................................................................................................................................90

14.4.4. Terminating an Ultra DMA data-out burst ........................................................................................................................................90 14.4.4.1 Host terminating an Ultra DMA data-out burst.....................................................................................................................................................90 14.4.4.2 Device terminating an Ultra DMA data-out burst.................................................................................................................................................91

14.5. ULTRA DMA CRC RULES.............................................................................................................................................................................92 15.SYSTEM ENVIRONMENTAL SPECIFICATIONS..................................................................................................................................94 15.1 TEMPERATURE TEST FLOW............................................................................................................................................................................94 15.2ALTITUDE TEST ...............................................................................................................................................................................................95

TCADO-SID-000009.2

6/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 1. Introduction 1.1 General Description C-ONE’s Tiger series MINI- IDE Card uses NAND-Type flash memory devices, which leads to its remarkable high performance and comes with capacities from 128 MB to 48GB unformatted. Compliant with ISA (Industrial Standard Architecture) bus interface standard, the S-CN IDE Card performs sequential read/write for each sector (512 bytes) count. It also conforms to IDE Specification and is designed with precision mechanics to enable host devices to read/write from the IDE interface into Flash Media. It can operate with a 5V single power from the host side. The card provides extraordinary memory medium for PC , C-ONE’s IDE Card has been approved through various compatibility tests.

TCADO-SID-000009.2

7/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 1.2 Features 

IDE interface ATA command set compatible Support for 8-bit or 16-bit host data transfer Program and auto-wait-state initiation for compatibility with any IORDY supporting host Compatibility with host ATA disk I/O BIOS, DOS/Windows file system, utilities, and application software



Extremely rugged and reliable Advanced defect block management Support background erased operation



5 Volt power supply, very low power consumption

● Internal self-diagnostic program operates at VCC power on ● Auto sleep mode  High reliability based on internal ECC (Error Correcting Code) function  Error Correcting of 4 bits random error per sector  Automatic on-the-fly, in-buffer Error Correcting  Zero-power data retention, no batteries required 

3 variations of mode access

● Memory card mode ● I/O card mode ● True IDE mode

- PIO Mode 4 - UDMA mode 4 - supported Multi word DMA Mode 2 .

TCADO-SID-000009.2

8/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 2. Product Specification 2.1 Operation and environment description Operating Voltage

DC Input Power

5V ± 10%

Read Mode: 40 mA(Max) Write Mode: 60 mA(Max) 5V Standby Mode: 6.5 mA(Approach values) Read/ Write Peak: 100mA Extended Temp. -20°C to +85°C Operating Temperature Industrial Temp. -40°C to +85°C Extended Temp. -40°C to +90°C Storage Temperature Industrial Temp. -50°C to +90°C Humidity Operation 5% to 95% (Non-condensing ) Environment conditions Humidity Non-operation 5% to 95% (Non-condensing ) Shock Operation 3000-G (Max.) Shock Non-operation 3000-G (Max.) Vibration Operation 30-G (Peak to peak to maximum) Vibration Non-operation 30-G (Peak to peak to maximum) DOS Operation System supported Compatibility (Microsoft Windows 98 Windows Vista Product) Windows NT Windows 2000 Windows XP Typical Power Consumptions:

TCADO-SID-000009.2

9/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 2.2 Physical description

1. Weight and Measures (unit: mm)

2. Storage Capacities

3. Performance:

4. Reliability:

Weight: 12 g MIDE 40-Pin (P or L form) Pin-pitch: 2.54 mm Weight: 12 g MIDE 44-Pin (P or L form) Pin-pitch: 2.0 mm Capacity 256MB to 8GB Read speed up to 35 Mbytes/sec (Max) Data Transfer Rates Write speed up to 32 Mbytes/sec (Max) Data Access Time Cylinder 0, head 0, sector 1. Regardless of the translation mode, a sector LBA address does not change. LBA = (Cylinder * no of heads + heads) * (sectors/track) + (Sector - 1).

TCADO-SID-000009.2

47/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9. ATA Commands 9.1 Check Power Mode - 98H or E5H This command checks the current power mode of the adapter. When this command is issued and the adapter is in standby mode, or is being set to standby mode, or during a recovery from standby mode is attempted, adapter sets the BSY bit in the Status register and sets the Sector Count Register to “00H”. Then the BSY bit in the Status register is cleared. When the adapter is in the Idle mode, it sets the BSY bit in the Status register and sets “FFH” in the Sector Count Register. Then the BSY bit in the Status register is cleared. An interrupt is issued after the BSY bit is cleared. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Command

7 6 N/A N/A N/A N/A N/A 98H or E5H

5

4

3

2

1

0

OUTPUTS Register Status Sector Count Error

TCADO-SID-000009.2

7 6 5 4 3 BSY DRDY DWF DSC DRQ V V V V V Power Mode Code.(00H or 80H or FFH) BBK UNC MC IDNF MCR

48/95

2 CORR

1 IDX

0 ERR V

ABRT V

TK0NF

AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.2 Execute Drive Diagnostic - 90H This command performs self-diagnostics on various internal components of the adapter. Results of the test are reported in the Error Register. Note that the bit definitions for the Error Register do not apply with this command. Instead, the value in the Error Register is a diagnostic code, defined in the table below. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

0

DEV 90H

OUTPUTS: The diagnostic code written into the Error Register is an 8-bit code as shown in the table below. Register Status Error Code 01H 02H 03H 04H 05H

TCADO-SID-000009.2

7 6 5 4 BSY DRDY DWF DSC V V V Diagnostic code, see table below

3 DRQ

2 CORR

1 IDX

0 ERR V

Description No error detected Format Media error Sector buffer error ECC logic error Controlling microprocessor error

49/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.3 Erase Sector(s) - C0H This command is processed as a NOP command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A [LBA mode only] The number of sectors to be formatted on the track, must be set to FFH [LBA mode only] LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA C0H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK V

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF V

50/95

3 DRQ

2 CORR

1 IDX

MCR

ABRT V

TK0NF

0 ERR V AMNF V

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.4 Format Track - 50H This command is processed as a NOP command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7

6

5

4

3

2

1

0

[LBA mode only] The number of sectors to be formatted on the track. Must be set to FFH [LBA mode only] LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA 50H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

51/95

4 DSC V IDNF V

3 DRQ

2 CORR

1 IDX

MCR

ABRT V

TK0NF

0 ERR V AMNF V

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.5 Identify Drive – ECH The Identify Drive command enables the host to receive parameter information from the adapter. When the command is issued, the adapter sets the BSY bit, prepares to transfer the 256 words of adapter identification data to the host, sets the DRQ bit, clears the BSY bit, and generates an interrupt. The host can then transfer the data by reading the Data register. All reserved bits or words are all zero. See following table for the identify drive information for this adapter INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0

DEV ECH

OUTPUTS Register Status

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

Error

TCADO-SID-000009.2

52/95

4 DSC V IDNF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.6 Idle - 97H or E3H Although this command is supported for backward compatibility, it has no actual function. The adapter will always return a ‘good’ status at the completion of this command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 N/A Time-out Parameter. This parameter is ignored by the adapter N/A N/A N/A DEV 97H or E3H

1

0

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

53/95

4 DSC V IDNF

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.7 Idle Immediate - 95H or E1H Although this command is supported for backward compatibility, it has no actual function. The adapter will always return a ‘good’ status at the completion of this command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0

DEV 95H or E1H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

54/95

4 DSC V IDNF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.8 Initialize Drive Parameters - 91H Initialize Drive Parameters allows the host to alter the number of sectors per track and the number of heads per cylinder. This command does not check the validity of counts of sectors and heads. If an invalid value is set, an error will be reported when another command attempts an invalid access. The Sector Count Register specifies the number of logical sectors per logical track, and the Device/Head register specifies the maximum head number. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 N/A Number of sectors N/A N/A N/A

5

4

3

2

1

DEV

Max Head (no. of head = 1)

0

91H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF MC

4 DSC V IDNF

55/95

3 DRQ V MCR

2 CORR

1 IDX

ABRT

TK0NF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.9 Read Buffer - E4H The Read Buffer command enables the host to read the current contents of the adapter’s sector buffer. This command has the same protocol as the Read Sector(s) command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

LBA

3

2

1

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0

DEV

E4H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

56/95

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.10 Read Long Sector(s) - 22H or 23H Read Long (w/ and w/o retry) is similar to the Read Sectors command, except that the content of the Sector Count Register is ignored and only one sector is read. The 512 data bytes and 4 ECC bytes are read into the buffer (with no ECC correction) and then transferred to the host. The Cylinder Low, Cylinder High, Device/Head and Sector Number specify the starting sector address to be read. The Sector Count Register shouldn’t specify a value other than 1. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A The number of sectors/logical blocks to transfer. This should be set to 01 for compatibility Sector[7:0] or LBA[7:0] of the sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the sector/LBA to transfer 22H (retries enabled) or 23H (retries disabled)

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V 00 if the command proceed without error, else the number of untransfered sectors. Sector[7:0] or LBA[7:0] of the last sector read Cylinder[7:0] or LBA[15:8] of the last sector read Cylinder[15:8] or LBA[23:16] of the last sector read BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V

57/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.11 Read Multiple - C4H This command functions like the Read Sector(s) command, but instead of issuing interrupts for each sector, interrupts are issued when a block containing the counts of sectors, defined by the Set Multiple command is, transferred. Also, the DRQ required for the transfer only has to be set at the start of the data block and does not affect other sectors. When the Read Multiple command is issued, the requested sectors (not the block counts or the sector counts in a block) are written into the Sector Count Register. Errors occurring during command execution are reported at the start of a block transfer or at the start of transfer of part of a block. However, the transfer continues even if DRQ is set and the data is corrupted. After the data transfer, the content of the task file with the block data containing the sectors where the error occurred is not defined. To obtain valid error information the host has to request a re-transmission. The next block or part of a block is transferred only if the error is correctable. For all other errors the command is aborted after transferring a block containing an error. The Read Multiple command is supported for backward compatibility. If R/W Multiple commands have been enabled by a previous valid Set Multiple command, the Read Multiple command is identical to the Read Sectors operation except that several sectors are transferred as a block to the Host without the intervening Host handshaking. The block count stands for the number of sectors to be transferred as a block. It is established using the Set Multiple command. Although the Set Multiple, and R/W Multiple commands are supported, the only valid block count is one. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 N/A The number of sectors/logical blocks to transfer Sector[7:0] or LBA[7:0] of the sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the sector/LBA to transfer LBA DEV Head number or LBA C4H

0

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Device/Head Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V V The first sector where the first unrecoverable error occurred Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred H[3:0] or LBA[27:24] last good sector transferred LBA DEV BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V V V V V

58/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.12 Read Sectors(s) – 20H or 21H The Cylinder Low, Cylinder High, Device/Head and Sector Number or LBA registers specify the starting sector address to be read. The Sector Count Register specifies the number of sectors to be transferred. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 N/A The number of sectors/logical blocks to transfer Sector[7:0] or LBA[7:0] of the sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the sector/LBA to transfer 20H (retry enabled) or 21H (retries disabled)

0

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Device/Head

Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V V The first sector where the first unrecoverable error occurred Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred LBA DEV H[3:0] or LBA[27:24] last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V V V V

59/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.13 Read Verify Sector(s) – 40H or 41H The Read Verify Sectors command verifies one or more sectors on the card by transferring data from the Flash media to the data buffer in the card and verifying that the ECC is correct. It is performed identically to the Read Sectors command, except that DRQ is not asserted, and no data is transferred to the host. If an uncorrectable error occurs, the Read Verify command will be terminated at the failing sector. The task file registers contain the CHS, or LBA of the sector in which the error occurred. The Cylinder Low, Cylinder High, Device/Head and Sector Number specify the starting sector address to be verified. The Sector Count Register specifies the number of sectors to be verified. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 N/A The number of sectors/logical blocks to verify Sector[7:0] or LBA[7:0] of the first sector/LBA to verify Cylinder[7:0] or LBA[15:8] of the sector/LBA to verify Cylinder[15:8] or LBA[23:16] of the first sector/LBA to verify LBA DEV H[3:0] or LBA[27:24] of the sector/LBA to verify 40H (retries enabled) or 41H (retries disabled)

0

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Device/Head

Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 BSY DRDY DWF DSC DRQ CORR IDX V V V V V V The first sector where the first unrecoverable error occurred Sector[7:0] or LBA[7:0] of the sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the last good sector transferred LBA DEV H[3:0] or LBA[27:24] of the sector/LBA to transfer BBK UNC MC IDNF MCR ABRT TK0NF V V V V V V

60/95

0 ERR V

AMNF V

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.14 Recalibrate - 1XH The adapter performs only the interface timing and register operations. When this command is issued, the adapter sets BSY and waits for an appropriate length of time after which it clears BSY and issues an interrupt. When this command ends normally, the adapter is initialized. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

3 DRQ

2 CORR

1 IDX

MCR

ABRT V

TK0NF

0

DEV 1XH

OUTPUTS

Register Status Error

TCADO-SID-000009.2

7 BSY BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

61/95

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.15 Request Sense - 03H This command requests extended error information for the previous command. The table below defines the valid extended error codes. Those codes are placed in the Error Register. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

0

DEV 03H

OUTPUTS The diagnostic code written into the Error Register is an 8-bit code as shown in the table below. Register Status Error

7 6 5 BSY DRDY DWF V V Sense code, see table below

Code 00H 01H 03H 09H 20H 21H 2FH 35H, 36H 11H 18H 05H, 30H-34H, 37H, 3EH 10H, 14H 3AH 1FH 0CH, 38H, 3BH, 3CH, 3FH

TCADO-SID-000009.2

4 DSC V

3 DRQ

2 CORR

1 IDX

0 ERR V

Description No error detected Self test OK (No error) Write/Erase failed Miscellaneous Error - N/A Invalid Command Invalid Address (requested Head or Sector invalid) Address Overflow (address too large) Supply or generate Voltage Out of Tolerance Uncorrectable ECC Error Corrected ECC Error - N/A Self Test Diagnostic Failed ID Not Found - N/A Spare Sectors Exhausted Data Transfer Error / Aborted Command Corrupted Media Format - N/A

62/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.16 Seek - 7XH This command seeks and picks up the head to track specified in the Task File registers. Actually the adapter performs only an interface timing and register information. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A N/A (Valid in LBA mode only) LBA[7:0] of the track Cylinder[7:0] or LBA[15:8] of the track Cylinder[15:8] or LBA[23:16] of the track LBA DEV H[3:0] or LBA[27:24] of the track 7XH

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC V

4 DSC V IDNF V

63/95

3 DRQ V MCR V

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.17 Set Feature - EFH This command is used by the host to establish or select from the specific features listed below.(after a power up or a hardware reset) An ATA software reset does not set the features to default. The feature code is set to 81H, this mode is the default mode. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 Feature number according to the table below Configuration required N/A N/A N/A DEV EFH

2

1

0

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

Feature Codes Code 01H 55H 66H 81H BBH CCH

Description Enable 8-bit data transfers Disable Read Look Ahead Disable reverting to power on defaults Disable 8-bit data transfers 4 bytes of ECC apply on read long/write long commands Enable reverting to power on defaults

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

64/95

3 DRQ V MCR

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.18 Set Multiple Mode - C6H The Set Multiple command allows the adapter to perform Read Multiple and Write Multiple operations. It also sets the block count (counts of sectors making up a block) for these commands. The sector count per block is placed is the Sector Count Register. The adapter supports only blocks with one sector. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 N/A Sector Count per Block( = 1) N/A N/A N/A DEV C6H

3

2

1

0

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

65/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.19 Set Sleep Mode - 99H or E6H This is the only command that allows the host to set the adapter into Sleep mode. When the adapter is set to sleep mode, the adapter clears the BSY line and issues an interrupt. The adapter enters sleep mode and the only method to make the adapter active again (back to normal operation) is by performing a hardware reset or software reset. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

0

DEV 99H/E6H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

66/95

3 DRQ V MCR

2 1 CORR IDX ABRT V

TK0NF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.20 Standby - 96H or E2H This command is sets the adapter in Standby mode. If the Sector Count Register is a value other than 0H, an Auto Power Down is enabled and when the adapter returns to the idle mode, the timer starts a countdown. The time is set in the Sector Count Register. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 N/A Time period value N/A N/A N/A

5

4

3

2

1

0

DEV 96H or E2H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

67/95

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.21 Standby Immediate 94H or E0H This command sets the adapter into standby mode. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

0

DEV 94H or E0H

OUTPUTS Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

68/95

3 DRQ V MCR

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.22 Translate Sector - 87H This command allows the host a method of determining the exact number of times a sector was used (erased). The controller responds with the 512-byte buffer of information that includes the Hot Count, if available, for the sector. This command is not supported in this adapter and will always return the Hot Count as “00”. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A Sector Count Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA 87H

OUTPUTS The diagnostic code written into the Error Register is an 8-bit code as shown in the table below. Register Status Error

Address 00H - 01H 02H 03H 04H - 06H 07H - 12H 13H 14H - 17H 18H - 1AH 1BH - 1FFH

TCADO-SID-000009.2

7 BSY V BBK V

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF V

3 DRQ

2 CORR

1 IDX

MCR

ABRT V

TK0NF

0 ERR V AMNF

Information Cylinder MSB (00H), Cylinder LSB (01H) Head Sector LBA MSB (04H) - LSB (06H) Reserved Erased Flag (FFH) = Erased; (00H) = Not Erased Reserved Hot Count MSB (18H) - LSB (1AH) Reserved

69/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.23 Wear Level - F5H This command is effectively a NOP command and only implemented for backward compatibility. The Sector Count Register will always return the value “00H”, indicating that wear leveling is not needed. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

0

DEV F5H

OUTPUTS Register Status Sector Count Error

TCADO-SID-000009.2

7 6 BSY DRDY V V Always “00H” BBK UNC V V

5 DWF V

4 DSC V

3 DRQ V

2 CORR

1 IDX

0 ERR V

MC V

IDNF V

MCR V

ABRT V

TK0NF

AMNF V

70/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.24 Write Buffer - E8H This command enables the host to rewrite the contents of the adapter data buffer in the adapter with the desired data sting. This data buffer can be accessed by and read by the Read Buffer Command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 N/A N/A N/A N/A N/A

6

5

4

3

2

1

0

2 CORR

1 IDX

ABRT V

TK0NF

0 ERR V AMNF

DEV E8H

OUTPUTS

Register Status Error

TCADO-SID-000009.2

7 BSY V BBK

6 DRDY V UNC

5 DWF V MC

4 DSC V IDNF

71/95

3 DRQ V MCR

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.25 Write Long Sector(s) 32H or 33H This command operates in the same way as the Write Sector command except that it writes data and ECC bytes for long commands directly from the sector buffer. ECC bytes for long commands are byte writes that consist of a 4-byte fixed length data. This command can write only one sector at a time. INPUT Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A “01h” Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA 32H or 33H

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 BSY

6 5 4 3 2 1 0 DRDY DWF DSC DRQ CORR IDX ERR V V V V V Bit-0 if the command proceeded successfully, other – untransferred sectors count Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V

72/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.26 Write Multiple - C5H This command functions in the same way as the Write Sector command. When this command is issued, the adapter sets the BSY within 400nsec. Interrupts are not issued for every sector but after one block consisting of the counts of sectors defined by the Set Multiple command is transferred. The DRQ required for the transfer only has to be set at the beginning of the block and does not affect other sectors. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A Sector Count Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LB[27:24] of the starting sector/LBA C5H

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V Bit-0 if the command proceeded successfully, other – untransferred sectors count Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V V V

73/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.27 Write Multiple without Erase – CDH This command is similar to the Write Multiple command with the exception that an implied erase before using this command. Please note that before using this command it is required to erase the respective sectors using the Erase Sector command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A Sector Count Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LB[27:24] of the starting sector/LBA CDH

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V Bit-0 if the command proceeded successfully, other – untransferred sectors count Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V V V

74/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.28 Write Sector(s) - 30H or 31H This command allows the host to write the specified number (1 to 256) of sectors in the Sector Count Register. A sector count of 0 indicates a write request of 256 sectors. The write operation starts from the sector specified in the Sector Number register. The command ends execution by placing the cylinder, head and sector number of the last written sector in the Task File registers. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A Sector Count Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA 30H or 31H

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V Bit-0 if the command proceeded successfully, other – untransferred sectors count Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V V V

75/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.29 Write Sector(s) without Erase - 38H This command is similar to the Write Sector command with the exception that an implied erase before using this command. Please note that before using this command it is required to erase the respective sectors using the Erase Sector command. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A Sector Count Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA 38H

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V Bit-0 if the command proceeded successfully, other – untransferred sectors count Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V

76/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 9.30 Write Verity - 3CH This command is similar to the Write Sector command with the exception that each sector is verified immediately after writing. INPUTS Register Features Sector Count Sector Number Cylinder Low Cylinder High Device/Head Command

7 6 5 4 3 2 1 0 N/A Sector Count Sector[7:0] or LBA[7:0] of the first sector/LBA to transfer Cylinder[7:0] or LBA[15:8] of the first sector/LBA to transfer Cylinder[15:8] or LBA[23:16] of the first sector/LBA to transfer LBA DEV H[3:0] or LBA[27:24] of the starting sector/LBA 3CH

OUTPUTS Register Status Sector Count Sector Number Cylinder Low Cylinder High Error

TCADO-SID-000009.2

7 6 5 4 3 2 1 0 BSY DRDY DWF DSC DRQ CORR IDX ERR V V V V V V Bit-0 if the command proceeded successfully, other – untransferred sectors count Sector[7:0] or LBA[7:0] of the last good sector transferred Cylinder[7:0] or LBA[15:8] of the last good sector transferred Cylinder[15:8] or LBA[23:16] of the last good sector transferred BBK UNC MC IDNF MCR ABRT TK0NF AMNF V V V V

77/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 10. Error Posting Command

Error Register BB

Check Power Mode Execute Drive Diags Format Track Identify Drive Idle Idle Immediate Initialize Drive params Recalibrate Read Buffer Read Long Read Multiple Read Sector(s) Read Verify Sector(s) Seek Set Features Set Multiple Mode Sleep Standby Standby Immediate Write Buffer Write Long Write Multiple Write Sector(s) Invalid Command

TCADO-SID-000009.2

y y y y

y y y

UNC

y y y y

IDN

ABR y

y

y y y y

y y y y y

y y y

y y y y y y y y y y y y y y y y y

78/95

Status Register T0N

AMN

y y y y y

DRD y

y y y y y y y y y y y y y y y y y y y y y y

EWF DSC CORR ERR y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y

0506 V2

註解 [JCL1]:

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 11. Identify Drive Information Word 0

Data 045AH

1 2 3 4 5 6 7-8 9 10-19 20 21 22 23-26 27-46 47 48 49

Note 1 0000h Note 1 0000H XXXXH Note 1 XXXXH XXXXH XXXXH 0002H 0002H 0004H XXXXH XXXXH 0001H 0000H 2F00H

TCADO-SID-000009.2

Description General configuration bit-significant information Bits Description 15-14 10=ATAPI device 11=Reserved 13 Reserved 12-8 Field indicates command packet set used by device 7 1=removable media device 6-5 00=Device shall set DRQ to one within 3 ms of receiving PACKET command. 01=Obsolete. 10=Device shall set DRQ to one within 50 us of PACKET command. 11=Reserved 4-3 Reserved. 2 Incomplete response 1-0 00=12 byte command packet 01=16 byte command packet 1x=Reserved Number of Cylinders Reserved Number of Heads Obsolete Obsolete Number of sectors per track Number of sectors per card (Word 7= MSW, Word 8= LSW ) Obsolete 20 ASCII char serial number. Obsolete Obsolete ECC bytes passed on Read/Write Long Commands Firmware revision in ASCII chars. Model Number (Vendor Unique) Maximum Block Count=1 for Read/Write Multiple command Reserved Capabilities: LBA supported (bit 9). Capabilities: LBA supported (bit 9). 79/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. Word

Data

50 51 52 53

0000H 0200H 0000H 0003H

54 55 56 57 58 59

Note 1 Note1 Note 1 Note 1 Note1 0100H

60 61 62 63

Note 1 Note 1 0000H 0001H

TCADO-SID-000009.2

Description 15 0= interleave DMA not supported 14 0=command queuing not supported 13 1=overlap operation supported 12 0=ATA software reset required (Obsolete) 11 0=IORDY not supported 10 0=IORDY maybe enable 9 0=LBA not supported 8 0=DMA not Supported 7-0 Vendor specification Reserved PIO data transfer cycle timing mode Obsolete Translation Parameters Vaild (bit0:Word54 to 58 are valid, bit1:Word 64 to 70 are valid) 15-3 Reserved 2 1= the field reported in word 88 are valid 0= the field reported in word 88 are not valid 1 1= the field reported in word 64-70 are valid 0= the field reported in word 64-70 are not valid 0 1= the field reported in word 54-58 are valid 0= the field reported in word 54-58 are not valid Number of Current Cylinders Number of Current Heads Number of Current Sectors Per Track LSW of the Current Capacity in Sectors MSW of the Current Capacity in Sectors Multiple sector setting If bit 8 is set to one, bits 7-0 reflect the number of sector currently set to transfer on a READ/WRITE MULTIPLE command. This filed may default to the preferred value for the device. Command Code: C6h LSW of the total number of user addressable LBA’s MSW of the total number of user addressable LBA’s Reserved 15-11 Reserved 10 1=Multiword DMA mode 2 is selected 0=Multiword DMA mode 2 is not selected 9 1= Multiword DMA mode 1 is selected 0=Multiword DMA mode 1 is not selected 80/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. Word

Data

64

0003H

65

01E0H (DMA 2) 0000H (PIO 4)

66

01E0H 0000H (PIO 4)

67

0078H

TCADO-SID-000009.2

Description 8 1= Multiword DMA mode 0 is selected 0=Multiword DMA mode 0 is not selected 7-3 Reserved 2 0= Multiword DMA mode 2 and below are not supported 1 0= Multiword DMA mode 1 and below are not supported 0 1= Multiword DMA mode 0 is supported Multiword DMA mode selected. Advanced PIO Modes supported (bit0: PIO-3, bit1:PIO4,supported) 15-8 Reserved 7-0 Supported Bits 7 through 0 of word 64 of the Identify Device parameter information is defined as the PIO data and register transfer supported field. If this field is supported, bit 1 of word 53 shall be set to one. Of these bits, bits 7 through 2 are Revered for future PIO modes. Bit 0, if set to one, indicated that the device supports PIO mode 3. All device except CFA and PCMCIA device shall support PIO mode 3 and shall set bit 0 to one. Bit 1, if set to one, indicated that the device support PIO mode 4. Minimum Multiword DMA transfer cycle time per word 15-0 Cycle time in nanoseconds If this field is supported, bit 1 of word 53 shall be set to one. Any device that supports Multiword DMA mode 1 or above shall support this field, and the value in word 65 shall not be less than the minimum cycle time for the fastest DMA mode supported by the device. If bit 1 of word 53 is set to one because a device supports a field in words 64-70 other than this filed and the device does not support this filed, the device shall return a value of zero in this field. Manufacturer’s recommended Multiword DMA transfer cycle time 15-0 Cycle time in nanoseconds If this field is supported, bit 1 of word 53 shall be set to one, Any device that supports Multiword DMA mode 1 or above shall support this field, and the value in word 66 shall not be less than the value in word 65. Minimum PIO transfer cycle time without flow control 81/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. Word

Data

68

0078H

69-79 80-81 82 83 84 85 86 87 88

0000H 0000H ... 0000H 0000H 0000H 0000H 0000H 0000H 0700H

89 90 91 92 - 127 128 129 - 159 160

0000H 0000H XXXXH 0000H 0000H 0000H 0000H

TCADO-SID-000009.2

Description 15-0 Cycle time in nanoseconds Minimum PIO transfer cycle time with IORDY flow control 15-0 Cycle time in nanoseconds Reserved (for feature command overlap and queuing) Reserved for CFA Features/Command sets supported Feature/Command sets supported Features/Command sets supported Features/Command sets supported Feature/Command sets supported Features/Command sets supported 15-14 Reserved 13 1= Ultra DMA mode 5 is selected 0=Ultra DMA mode 5 is not selected 12 1= Ultra DMA mode 4 is selected 0=Ultra DMA mode 4 is not selected 11 1= Ultra DMA mode 3 is selected 0=Ultra DMA mode 3 is not selected 10 1= Ultra DMA mode 2 is selected 0=Ultra DMA mode 2 is not selected 9 1= Ultra DMA mode 1 is selected 0=Ultra DMA mode 1 is not selected 8 1= Ultra DMA mode 0 is selected 0=Ultra DMA mode 0 is not selected 7-6 Reserved 5 0= Ultra DMA mode 5 and below are not supported 4 1= Ultra DMA mode 4 and below are supported 3 1= Ultra DMA mode 3 and below are supported 2 1= Ultra DMA mode 2 and below are supported 1 1= Ultra DMA mode 1 and below are supported 0 1= Ultra DMA mode 0 is supported Time required for Security erase unit completion Time required for Enhanced security erase unit completion Current Advanced power management value Reserved Security status Vendor unique bytes Power requirement description 82/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. Word 161 162 163 - 255 Note1:

Data Description 0000H Reserved 0000H Key management schemes supported 0000H Total 166 Bytes Reserved Variable by capacity

TCADO-SID-000009.2

83/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 12. ATA Protocol Overview Command classes are grouped according to protocols described for command execution. For all commands, the host must first check for BYS=0 before proceeding further. For most commands, the host should not proceed until DRDY=1.

12.1 PIO Data In Commands Execution includes one more 512 bytes data-sector drive-to-host transfer. If the drive presents error status, it prepares to transfer data at the host's discretion. The host writes parameters to the Feature, Sector Count, Sector Number, Cylinder, and Drive/Head register. The host writes the Command Register's command code. The drive sets BSY and prepares for data transfer when a data sector is available; the drive sets DRQ, clears BSY, and asserts interrupt. At interrupt, the host reads the Status register, the drive negates interrupt, and the host reads one data-sector from Data Register. The drive clears DRQ. If another sector is required, the drive sets BSY and repeats the data transfer from 4.

12.2 PIO Data Out Commands Execution includes one or more 512 bytes host-to-drive data-sector transfers. The host writes parameters to the Features, Sector Count, Sector Number, Cylinder, and Drive/Head Registers. The host writes the Command register's command code. The drive sets DRQ when it can accept the first sector of data The host writes one sector of data to the Data register. The Drive clears DRQ and sets BSY. At sector processing complete, the drive clears BSY and asserts interrupt. If another sector transfer is required, the drive also sets DRQ. The host reads the Status register after detecting interrupt. The drive negates the interrupt if another sector transfer is required, the sequence repeats from 4.

12.3 Non Data Commands Command execution involves no data transfer. The host writes parameters to the Features, Sector Count, Sector Number, Cylinder, and Drive/Head registers. The host writes the Command register's command code. The Drive sets BSY. When the drive completes sector processing, it clears BSY and asserts interrupt. The host reads the Status register after detecting interrupts the drive negates the interrupt.

TCADO-SID-000009.2

84/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 14. Ultra DMA data-in commands 14.1. Initiating an Ultra DMA data-in burst The following steps shall occur in the order they are listed unless otherwise specified. a) The host shall keep DMACK- in the negated state before an Ultra DMA burst is initiated. b) The device shall assert DMARQ to initiate an Ultra DMA burst when DMACK- is negated. Afterassertion of DMARQ the device shall not negate DMARQ until after the first negation of DSTROBE. c) Steps (c), (d), and (e) may occur in any order or at the same time. The host shall assert STOP. d) The host shall negate HDMARDY-. e) The host shall negate CS0-, CS1-, DA2, DA1, and DA0. The host shall keep CS0-, CS1-, DA2, DA1, and DA0 negated until after negating DMACK- at the end of the burst. f) Steps (c), (d), and (e) shall have occurred at least tACK before the host asserts DMACK-. The host shall keep DMACK- asserted until the end of an Ultra DMA burst. g) The host shall release DD(15:0) within tAZ after asserting DMACK-. h) The device may assert DSTROBE tZIORDY after the host has asserted DMACK-. Once the device has driven DSTROBE the device shall not release DSTROBE until after the host has negated DMACK- at the end of an Ultra DMA burst. i) The host shall negate STOP and assert HDMARDY- within tENV after asserting DMACK-. After negating STOP and asserting HDMARDY-, the host shall not change the state of either signal until after receiving the first negation of DSTROBE from the device (i.e., after the first data word has been received). j) The device shall drive DD(15:0) no sooner than tZAD after the host has asserted DMACK-, negated STOP, and asserted HDMARDY-. k) The device shall drive the first word of the data transfer onto DD(15:0). This step may occur when the device first drives DD(15:0) in step (j). l) To transfer the first word of data the device shall negate DSTROBE within tFS after the host has negated STOP and asserted HDMARDY-. The device shall negate DSTROBE no sooner than tDVS after driving the first word of data onto DD(15:0).

14.2. The data-in transfer The following steps shall occur in the order they are listed unless otherwise specified. a) The device shall drive a data word onto DD(15:0). b) The device shall generate a DSTROBE edge to latch the new word no sooner than tDVS after changing the state of DD(15:0). The device shall generate a DSTROBE edge no more frequently than tCYC for the TCADO-SID-000009.2

85/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. selected Ultra DMA mode. The device shall not generate two rising or two falling DSTROBE edges more frequently than t2cyc for the selected Ultra DMA mode. c) The device shall not change the state of DD(15:0) until at least tDVH after generating a DSTROBE edge to latch the data. d) The device shall repeat steps (a), (b), and (c) until the Ultra DMA burst is paused or terminated by the device or host.

14.3. Pausing an Ultra DMA data-in burst The following steps shall occur in the order they are listed unless otherwise specified. 14.3.1. Device pausing an Ultra DMA data-in burst a) The device shall not paused an Ultra DMA burst until at least one data word of an Ultra DMA burst has been transferred. b) The device shall pause an Ultra DMA burst by not generating additional DSTROBE edges. If the host is ready to terminate the Ultra DMA burst. c) The device shall resume an Ultra DMA burst by generating a DSTROBE edge. 14.3.2. Host pausing an Ultra DMA data-in burst a) The host shall not pause an Ultra DMA burst until at least one data word of an Ultra DMA burst has been transferred. b) The host shall pause an Ultra DMA burst by negating HDMARDY-. c) The device shall stop generating DSTROBE edges within tRFS of the host negating HDMARDY-. d) When operating in Ultra DMA modes 2, 1, or 0: If the host negates HDMARDY- within tSR after the device has generated a DSTROBE edge, then the host shall be prepared to receive zero or one additional data words; or, if the host negates HDMARDY- greater than tSR after the device has generated a DSTROBE edge, then the host shall be prepared to receive zero, one or two additional data words. While operating in Ultra DMA modes 4 or 3 the host shall be prepared to receive zero, one, two or three additional data words after negating HDMARDY-. The additional data words are a result of cable round trip delay and tRFS timing for the device. e) The host shall resume an Ultra DMA burst by asserting HDMARDY-.

14.3.3. Terminating an Ultra DMA data-in burst 14.3.3.1. Device terminating an Ultra DMA data-in burst

Burst termination is completed when the termination protocol has been executed and DMACK- negated. The device shall terminate an Ultra DMA burst before command completion. The following steps shall occur in the order they are listed unless otherwise specified. TCADO-SID-000009.2

86/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp.  The device shall initiate termination of an Ultra DMA burst by not generating additional DSTROBE edges.  The device shall negate DMARQ no sooner than tSS after generating the last DSTROBE edge. The device shall not assert DMARQ again until after DMACK- has been negated.  The device shall release DD(15:0) no later than tAZ after negating DMARQ.  The host shall assert STOP within tLI after the device has negated DMARQ. The host shall not negate STOP again until after the Ultra DMA burst is terminated.  The host shall negate HDMARDY- within tLI after the device has negated DMARQ. The host shall continue to negate HDMARDY- until the Ultra DMA burst is terminated. Steps (d) and (e) may occur at the same time.  The host shall drive DD(15:0) no sooner than tZAH after the device has negated DMARQ. For this step, the host may first drive DD(15:0) with the result of the host CRC calculation (see 9.15);  If DSTROBE is negated, the device shall assert DSTROBE within tLI after the host has asserted STOP. No data shall be transferred during this assertion. The host shall ignore this transition on DSTROBE. DSTROBE shall remain asserted until the Ultra DMA burst is terminated.  If the host has not placed the result of the host CRC calculation on DD(15:0) since first driving DD(15:0) during (f), the host shall place the result of the host CRC calculation on DD(15:0) (see 9.15).  The host shall negate DMACK- no sooner than tMLI after the device has asserted DSTROBE and negated DMARQ and the host has asserted STOP and negated HDMARDY-, and no sooner than tDVS after the host places the result of the host CRC calculation on DD(15:0).  The device shall latch the host’s CRC data from DD(15:0) on the negating edge of DMACK-.  The device shall compare the CRC data received from the host with the results of the device CRC calculation. If a miscompare error occurs during one or more Ultra DMA bursts for any one command, at the end of the command the device shall report the first error that occurred (see 9.15).  The device shall release DSTROBE within tIORDYZ after the host negates DMACK-.  The host shall not negate STOP nor assert HDMARDY- until at least tACK after negating DMACK-.  The host shall not assert DIOR-, CS0-, CS1-, DA2, DA1, or DA0 until at least tACK after negating DMACK. 14.3.3.2. Host terminating an Ultra DMA data-in burst

The following steps shall occur in the order they are listed unless otherwise specified. a) The host shall not initiate Ultra DMA burst termination until at least one data word of an Ultra DMA burst has been transferred. b) b) The host shall initiate Ultra DMA burst termination by negating HDMARDY-. The host shall continue to negate HDMARDY- until the Ultra DMA burst is terminated. c) The device shall stop generating DSTROBE edges within tRFS of the host negating HDMARDY-. d) When operating in Ultra DMA modes 2, 1, or 0: If the host negates HDMARDY- within tSR after the device has generated a DSTROBE edge, then the host shall be prepared to receive zero or one additional TCADO-SID-000009.2

87/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. data words; or, if the host negates HDMARDY- greater than tSR after the device has generated a DSTROBE edge, then the host shall be prepared to receive zero, one or two additional data words. While operating in Ultra DMA modes 4 or 3 the host shall be prepared to receive zero, one, two or three additional data words after negating HDMARDY-. The additional data words are a result of cable round trip delay and tRFS timing for the device. e) The host shall assert STOP no sooner than tRP after negating HDMARDY-. The host shall not negate STOP again until after the Ultra DMA burst is terminated. f) The device shall negate DMARQ within tLI after the host has asserted STOP. The device shall not assert DMARQ again until after the Ultra DMA burst is terminated. g) If DSTROBE is negated, the device shall assert DSTROBE within tLI after the host has asserted STOP. No data shall be transferred during this assertion. The host shall ignore this transition on DSTROBE. DSTROBE shall remain asserted until the Ultra DMA burst is terminated. h) The device shall release DD(15:0) no later than tAZ after negating DMARQ. i) The host shall drive DD(15:0) no sooner than tZAH after the device has negated DMARQ. For this step, the host may first drive DD(15:0) with the result of the host CRC calculation . j) If the host has not placed the result of the host CRC calculation on DD(15:0) since first driving DD(15:0) during (9), the host shall place the result of the host CRC calculation on DD(15:0). k) The host shall negate DMACK- no sooner than tMLI after the device has asserted DSTROBE and negated DMARQ and the host has asserted STOP and negated HDMARDY-, and no sooner than tDVS after the host places the result of the host CRC calculation on DD(15:0). l) The device shall latch the host’s CRC data from DD(15:0) on the negating edge of DMACK-. m) The device shall compare the CRC data received from the host with the results of the device CRC calculation. If a miscompare error occurs during one or more Ultra DMA burst for any one command, at the end of the command, the device shall report the first error that occurred. n) The device shall release DSTROBE within tIORDYZ after the host negates DMACK-. o) The host shall neither negate STOP nor assert HDMARDY- until at least tACK after the host has negated DMACK-. p) The host shall not assert DIOR-, CS0-, CS1-, DA2, DA1, or DA0 until at least tACK after negating DMACK.

TCADO-SID-000009.2

88/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 14.4. Ultra DMA data-out commands 14.4.1. Initiating an Ultra DMA data-out burst The following steps shall occur in the order they are listed unless otherwise specified. a) The host shall keep DMACK- in the negated state before an Ultra DMA burst is initiated. b) The device shall assert DMARQ to initiate an Ultra DMA burst when DMACK- is negated. c) Steps (c), (d), and (e) may occur in any order or at the same time. The host shall assert STOP. d) The host shall assert HSTROBE. e) The host shall negate CS0-, CS1-, DA2, DA1, and DA0. The host shall keep CS0-, CS1-, DA2, DA1, and DA0 negated until after negating DMACK- at the end of the burst. f) Steps (c), (d), and (e) shall have occurred at least tACK before the host asserts DMACK-. The host shall keep DMACK- asserted until the end of an Ultra DMA burst. g) The device may negate DDMARDY- tZIORDY after the host has asserted DMACK-. Once the device has negated DDMARDY-, the device shall not release DDMARDY- until after the host has negated DMACK- at the end of an Ultra DMA burst. h) The host shall negate STOP within tENV after asserting DMACK-. The host shall not assert STOP until after the first negation of HSTROBE. i) The device shall assert DDMARDY- within tLI after the host has negated STOP. After asserting DMARQ and DDMARDY- the device shall not negate either signal until after the first negation of HSTROBE by the host. j) The host shall drive the first word of the data transfer onto DD(15:0). This step may occur any time during Ultra DMA burst initiation. k) To transfer the first word of data: the host shall negate HSTROBE no sooner than tUI after the device has asserted DDMARDY-. The host shall negate HSTROBE no sooner than tDVS after the driving the first word of data onto DD(15:0). 14.4.2. The data-out transfer The following steps shall occur in the order they are listed unless otherwise specified. a) The host shall drive a data word onto DD(15:0). b) The host shall generate an HSTROBE edge to latch the new word no sooner than tDVS after changing the state of DD(15:0). The host shall generate an HSTROBE edge no more frequently than tCYC for the selected Ultra DMA mode. The host shall not generate two rising or falling HSTROBE edges more frequently than t2cyc for the selected Ultra DMA mode. c) The host shall not change the state of DD(15:0) until at least tDVH after generating an HSTROBE edge to latch the data. TCADO-SID-000009.2

89/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. d) The host shall repeat steps (a), (b), and (c) until the Ultra DMA burst is paused or terminated by the device or host. 14.4.3. Pausing an Ultra DMA data-out burst The following steps shall occur in the order they are listed unless otherwise specified. 14.4.3.1 Host pausing an Ultra DMA data-out burst

a) The host shall not pause an Ultra DMA burst until at least one data word of an Ultra DMA burst has been transferred. b) The host shall pause an Ultra DMA burst by not generating an HSTROBE edge. If the host is ready to terminate the Ultra DMA burst. c) The host shall resume an Ultra DMA burst by generating an HSTROBE edge . 12.4.3.2. Device pausing an Ultra DMA data-out burst a) The device shall not pause an Ultra DMA burst until at least one data word of an Ultra DMA burst has been transferred. b) The device shall pause an Ultra DMA burst by negating DDMARDY-. c) The host shall stop generating HSTROBE edges within tRFS of the device negating DDMARDY-. d) When operating in Ultra DMA modes 2, 1, or 0: If the device negates DDMARDY- within tSR after the host has generated an HSTROBE edge, then the device shall be prepared to receive zero or one additional data words; or, if the device negates DDMARDY- greater than tSR after the host has generated an HSTROBE edge, then the device shall be prepared to receive zero, one or two additional data words. While operating in Ultra DMA modes 4 or 3 the device shall be prepared to receive zero, one, two or three additional data words after negating DDMARDY-. The additional data words are a result of cable round trip delay and tRFS timing for the host. e) The device shall resume an Ultra DMA burst by asserting DDMARDY-. 14.4.4. Terminating an Ultra DMA data-out burst 14.4.4.1 Host terminating an Ultra DMA data-out burst

The following steps shall occur in the order they are listed unless otherwise specified. a) The host shall initiate termination of an Ultra DMA burst by not generating additional HSTROBE edges. b) The host shall assert STOP no sooner than tSS after the last generated an HSTROBE edge. The host shall not negate STOP again until after the Ultra DMA burst is terminated. c) The device shall negate DMARQ within tLI after the host asserts STOP. The device shall not assert DMARQ again until after the Ultra DMA burst is terminated. d) The device shall negate DDMARDY- within tLI after the host has negated STOP. The device shall not assert DDMARDY- again until after the Ultra DMA burst termination is complete. TCADO-SID-000009.2

90/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. e) If HSTROBE is negated, the host shall assert HSTROBE within tLI after the device has negated DMARQ. No data shall be transferred during this assertion. The device shall ignore this transition on HSTROBE. HSTROBE shall remain asserted until the Ultra DMA burst is terminated. f) The host shall place the result of the host CRC calculation on DD(15:0) g) The host shall negate DMACK- no sooner than tMLI after the host has asserted HSTROBE and STOP and the device has negated DMARQ and DDMARDY-, and no sooner than tDVS after placing the result of the host CRC calculation on DD(15:0). h) The device shall latch the host’s CRC data from DD(15:0) on the negating edge of DMACK-. i) The device shall compare the CRC data received from the host with the results of the device CRC calculation. If a miscompare error occurs during one or more Ultra DMA bursts for any one command, at the end of the command, the device shall report the first error that occurred. j) The device shall release DDMARDY- within tIORDYZ after the host has negated DMACK-. k) The host shall neither negate STOP nor negate HSTROBE until at least tACK after negating DMACK-. l) The host shall not assert DIOW-, CS0-, CS1-, DA2, DA1, or DA0 until at least tACK after negating DMACK. 14.4.4.2 Device terminating an Ultra DMA data-out burst

Burst termination is completed when the termination protocol has been executed and DMACK- negated. The device shall terminate an Ultra DMA burst before command completion. The following steps shall occur in the order they are listed unless otherwise specified. a) The device shall not initiate Ultra DMA burst termination until at least one data word of an Ultra DMA burst has been transferred. b) The device shall initiate Ultra DMA burst termination by negating DDMARDY-. c) The host shall stop generating an HSTROBE edges within tRFS of the device negating DDMARDY-. d) When operating in Ultra DMA modes 2, 1, or 0: If the device negates DDMARDY- within tSR after the host has generated an HSTROBE edge, then the device shall be prepared to receive zero or one additional data words; or, if the device negates DDMARDY- greater than tSR after the host has generated an HSTROBE edge, then the device shall be prepared to receive zero, one or two additional data words. While operating in Ultra DMA modes 4 or 3 the device shall be prepared to receive zero, one, two or three additional data words after negating DDMARDY-. The additional data words are a result of cable round trip delay and tRFS timing for the host. e) The device shall negate DMARQ no sooner than tRP after negating DDMARDY-. The device shall not assert DMARQ again until after DMACK- is negated. f) The host shall assert STOP within tLI after the device has negated DMARQ. The host shall not negate STOP again until after the Ultra DMA burst is terminated. g) If HSTROBE is negated, the host shall assert HSTROBE within tLI after the device has negated TCADO-SID-000009.2

91/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. DMARQ. No data shall be transferred during this assertion. The device shall ignore this transition of HSTROBE. HSTROBE shall remain asserted until the Ultra DMA burst is terminated. h) The host shall place the result of the host CRC calculation on DD(15:0). i) The host shall negate DMACK- no sooner than tMLI after the host has asserted HSTROBE and STOP and the device has negated DMARQ and DDMARDY-, and no sooner than t DVS after placing the result of the host CRC calculation on DD(15:0). j) The device shall latch the host’s CRC data from DD(15:0) on the negating edge of DMACK-. k) The device shall compare the CRC data received from the host with the results of the device CRC calculation. If a miscompare error occurs during one or more Ultra DMA bursts for any one command, at the end of the command, the device shall report the first error that occurred. l) The device shall release DDMARDY- within tIORDYZ after the host has negated DMACK-. m) The host shall neither negate STOP nor HSTROBE until at least tACK after negating DMACK-. n) The host shall not assert DIOW-, CS0-, CS1-, DA2, DA1, or DA0 until at least tACK after negating DMACK.

14.5. Ultra DMA CRC rules The following is a list of rules for calculating CRC, determining if a CRC error has occurred during an Ultra DMA burst, and reporting any error that occurs at the end of a command. 1) Both the host and the device shall have a 16-bit CRC calculation function. 2) Both the host and the device shall calculate a CRC value for each Ultra DMA burst. 3) The CRC function in the host and the device shall be initialized with a seed of 4ABAh at the beginning of an Ultra DMA burst before any data is transferred. 4) For each STROBE transition used for data transfer, both the host and the device shall calculate a new CRC value by applying the CRC polynomial to the current value of their individual CRC functions and the word being transferred. CRC is not calculated for the return of STROBE to the asserted state after the Ultra DMA burst termination request has been acknowledged. 5) At the end of any Ultra DMA burst the host shall send the results of the host CRC calculation function to the device on DD(15:0) with the negation of DMACK-. 6) The device shall then compare the CRC data from the host with the calculated value in its own CRC calculation function. If the two values do not match, the device shall save the error. A subsequent Ultra DMA burst for the same command that does not have a CRC error shall not clear an error saved from a previous Ultra DMA burst in the same command. If a miscompare error occurs during one or more Ultra DMA bursts for any one command, the device shall report the first error that occurred. If the device detects that a CRC error has occurred before data transfer for the command is complete, the device may complete the transfer and report the error or abort the command and report the error. TCADO-SID-000009.2

92/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 7) For READ DMA, WRITE DMA, READ DMA QUEUED, or WRITE DMA QUEUED commands: When a CRC error is detected, the error shall be reported by setting both ICRC and ABRT (bit 7 and bit 2 in the Error register) to one. ICRC is defined as the “Interface CRC Error” bit. The host shall respond to this error by re-issuing the command. 8) For a REQUEST SENSE packet command (see SPC T10/955D for definition of the REQUEST SENSE command): When a CRC error is detected during transmission of sense data the device shall complete the command and set CHK to one. The device shall report a Sense key of 0Bh (ABORTED COMMAND). The device shall preserve the original sense data that was being returned when the CRC error occurred. The device shall not report any additional sense data specific to the CRC error. The host device driver may retry the REQUEST SENSE command or may consider this an unrecoverable error and retry the command that caused the Check Condition. 9) For any packet command except a REQUEST SENSE command: If a CRC error is detected, the device shall complete the command with CHK set to one. The device shall report a Sense key of 04h (HARDWARE ERROR). The sense data supplied via a subsequent REQUEST SENSE command shall report an ASC/ASCQ value of 08h/03h (LOGICAL UNIT COMMUNICATION CRC ERROR). Host drivers should retry the command that resulted in a HARDWARE ERROR. 10) A host may send extra data words on the last Ultra DMA burst of a data-out command. If a device determines that all data has been transferred for a command, the device shall terminate the burst. A device may have already received more data words than were required for the command. These extra words are used by both the host and the device to calculate the CRC, but, on an Ultra DMA data-out burst, the extra words shall be discarded by the device. 11) The CRC generator polynomial is: G(X) = X16 + X12 + X5 + 1. Table 46 describes the equations for 16- bit parallel generation of the resulting polynomial (based on a word boundary).

NOTE Since no bit clock is available, the recommended approach for calculating CRC is to use a word clock derived from the bus strobe. The combinational logic is then equivalent to shifting sixteen bits serially through the generator polynomial where DD0 is shifted in first and DD15 is shifted in last. NOTE If excessive CRC errors are encountered while operating in an Ultra mode, the host should select a slower Ultra mode. Caution: CRC errors are detected and reported only while operating in an Ultra mode.

TCADO-SID-000009.2

93/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 15.System Environmental Specifications 15.1 Temperature Test Flow

TCADO-SID-000009.2

94/95

0506 V2

Tiger Series MINI-IDE Industrial Application C-ONE TECHNOLOGY Corp. 15.2Altitude Test

Altitude Altitude(relative to sea level)

TCADO-SID-000009.2

Product Operating &Non- Operating

95/95

80,000 feet maximum

0506 V2